RACM550-36SG [RECOM]
550 Watt 5â x 3â Open Frame or Enclosed Single Output;型号: | RACM550-36SG |
厂家: | RECOM INTERNATIONAL POWER |
描述: | 550 Watt 5â x 3â Open Frame or Enclosed Single Output |
文件: | 总10页 (文件大小:1508K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 300W baseplate-cooled, fan-less operation
• 550W peak power or forced air rating
• Industrial, household and medical 2MOPP ready
• Standby power consumption <0.5W
Features
AC/DC Converter
Regulated
Converter
• Operating temperature -40°C to +70°C
• Signals: remote sensing and ON/OFF control
RACM550-G
Description
550 Watt
5” x 3”
Open Frame or
Enclosed
Single Output
The RACM550 Series is designed to support up to 300 Watt continuous output power without
fan cooling.The compact 5”x 3”baseplate design enables direct heat dissipation through metal housings
in the application. Up to 550 watts are available to drive dynamic loads for several seconds of peak
power or with forced air for even longer time frames. A smart fan output is on board as standard
as well as a 5V/1A VSB output for applications with housekeeping circuits and on/off control.
A wide input range of 80 to 264VAC, up to 5000m operating altitude and international safety
agency certifications make the series worldwide suitable for BF-rated applied parts, household and
industrial ITE applications.
Selection Guide
Part
Number
Input
Voltage Range
[VAC]
Nom. Output
Voltage
Max. Output
Current (1)
[A]
Efficiency
typ. (2)
[%]
[VDC]
RACM550-24SG(3)
RACM550-36SG(3)
RACM550-48SG(3)
RACM550-56SG(3)
80-264
80-264
80-264
80-264
24
36
48
56
22.92
15.28
11.46
9.82
93
93
93
94
Notes:
Note1: With forced air cooling (2.5m/s) + conduction cooling + refer to “Line Derating”
Note2: Efficiency is tested at nominal input and full load at +25°C ambient
Model Numbering
E314885
RACM550-__ SG/
(3)
max. Output Power
“Case Option ”
nom. Output Voltage
Single
2MOPP
250VAC
Notes:
UL62368-1 (TÜV NRTL) certified
CAN/CAS C22.2 No. 62368-1 certified
IEC/EN62368-1 certified
ANSI/AAMI ES60601-1 certified
CSA/CAN 22.2 60950-1-14 certified
IEC/EN60335-1 certified
IEC/EN60601-1 (pending)
IEC/EN60950-1 (pending)
IEC/EN61558-1 (pending)
IEC/EN61558-2-16 (pending)
EN55032 compliant
Note3: add suffix “/OF” for open frame version
add suffix “/ENC” for enclosed version (MOQ 1000pcs)
Ordering Examples:
RACM550-24SG/OF
24Vout
Single
Single
open frame
enclosed
RACM550-36SG/ENC 24Vout
EN55024 compliant
CB Report
www.recom-power.com
REV.: 0/2020
PA-1
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Nom. Input Voltage
100VAC
240VAC
80VAC
120VDC
264VAC
370VDC
Input Voltage Range (4)
115VAC
230VAC
6.5A
3.0A
Input Current
115VAC
230VAC
40A
60A
Inrush Current
No load Power Consumption
Standby Power
2W
main output OFF, VSB Output unloaded
AC input
0.5W
63Hz
Input Frequency Range
47Hz
0%
ErP Lot 6 Standby Mode Conformity
(VSB Output Load Capability)
Input Power= 1W (main output= standby mode)
450mW
Minimum Load
115VAC
230VAC
0.98
0.95
0.99
0.97
Power Factor
main output
VSB Output
115VAC/230VAC
115VAC/230VAC
400ms
140ms
Start-up Time
Rise Time
main output
VSB Output
115VAC/230VAC
115VAC/230VAC
15ms
5ms
main output
VSB Output
115VAC/230VAC, 550W
115VAC/230VAC
15ms
130ms
Hold-up Time
1% of Vout nom. max.
120mVp-p
main output
VSB Output
Output Ripple and Noise(5)
20MHz BW @ 25°C
Notes:
Note4: The products were submitted for safety files at AC-input operation. For DC-input make sure that sufficient fuses are used
Note5: Measurements are made with a 12“ twisted pair-wire terminated with a 0.1µF and 10µF parallel capacitor
Efficiency vs. Load
100
90
80
70
60
50
40
30
20
10
0
115VAC
230VAC
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
main output
VSB output
3.0% max.
4.0% max.
Output Accuracy
Line Regulation
Load Regulation (6)
low line to high line, full load
10% to 100% load
main output / VSB output
main output / VSB output
1.0% max.
1.0% max.
Notes:
Note6: Operation below 10% load will not harm the converter, but specifications may not be met
www.recom-power.com
REV.: 0/2020
PA-2
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
ADDITIONAL FEATURES
Parameter
Condition
Min.
Typ.
Max.
CTRL ON
CTRL OFF
115VAC/230VAC
5W
VSB Output Power
230VAC
115VAC
5W
1W
(7)
Output Voltage Adjustability
ON/OFF CTRL
on-board potentiometer
2VDC
CON3, Pin3
main and FAN output ON
main and FAN output OFF
2.4VDC - 5VDC or open
0VDC - 0.8VDC or shorted to GND
(refer to “VSB & CTRL (CON3)“
continuous
peak (1s)
250mA
500mA
Fan Output Power
Remote Sense (8)
Power OK LED
Notes:
@ +50°C (not protected)
2VDC
LED = green
LED = red
working
failure
Note7: By trimming up, decrease output current to avoid exceeding rated output power. By trimming down, do not exceed maximum continuous output current
Note8: The output voltage can be adjusted by both ADJ (potentiometer) and Sense. The maximum combined adjustment range is 2VDC
REMOTE SENSE
RW1
+Vout
+Vout
VACIN (L)
PE
VACin(L)
VACin(N)
+Sense
RW ... wire losses +
1
RW ... wire losses -
2
-Sense
-Vout
-Vout
VACIN (N)
RW2
PROTECTIONS (Fan output not protected)
Parameter
Type
internal
Value
2x T6.3A, slow blow type
OVCII
Input Fuse (9)
Over Voltage Category (OVC)
Class of Equipment
Isolation Voltage (safety certified) (10)
Isolation Resistance
Insulation Grade
Class I
I/P to O/P
1 minute
4kVAC
10MΩ min.
reinforced
Leakage Current
0.25mA max.
2MOPP
Means of Protection
250VAC working voltage
Notes:
Note9: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Note10: For repeat Hi-Pot testing, reduce the time and/or the test voltage
PROTECTIONS MAIN OUTPUT
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Current Protection (OCP)
Over Temperature Protection (OTP)
below 100mΩ
Pin =10W max.
hiccup mode, auto recovery
110% - 120%, hiccup mode
105% - 135%, hiccup mode
auto recovery, internal temperature sensors
PROTECTIONS AUX (VSB)
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Current Protection (OCP)
below 100mΩ
hiccup mode, auto recovery
8-9VDC, hiccup mode
2.5-3.5A, hiccup mode
www.recom-power.com
REV.: 0/2020
PA-3
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range
Temperature Coefficient
Operating Altitude (11)
Operating Humidity
Pollution Degree
Shock
refer to derating graphs (valid for /OF and /ENC)
-40°C to +70°C
0.02%/K
5000m
20% - 90% RH max.
non-condensing
PD2
250m/s², 6ms; 3 times, each along x, y, z axes
90-200Hz, 10m/s²; 3.5min./1cycle, 5 periods, each along x, y, z axes
Vibration
+25°C (forced air cooling)
+45°C (forced air cooling)
200 x 103 hours
50 x 103 hours
according to MIL-217F Method 2
Components Stress Method
MTBF
Notes:
Note11: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.
Please contact RECOM tech support for advice.
Thermal Derating 115VAC
Line Derating (<115VAC)
100
550
500
450
400
350
300
250
200
150
100
50
90
80
70
60
50
40
30
20
10
0
115VAC, 4.5m/s forced cooling
115VAC, conduction cooling
115VAC, convection cooling
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80
45
80 90 100
115
Ambient Temperature [°C]
Input Voltage [VAC]
Thermal Derating 230VAC
550
500
450
400
350
300
250
200
150
100
50
230VAC, 2.5m/s forced cooling
230VAC, conduction cooling
230VAC, convection cooling
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80
Ambient Temperature [°C]
<0.1m/s = still air
0.1 - 0.2m/s = natural convection
continued on next page
REV.: 0/2020
www.recom-power.com
PA-4
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
Peak Load Capability
Pout [W]
Calculation
Pnom = nom. output power
Pp
[W]
PP = peak output power (≤550W) [W]
Pnom x (t1set + t2) - (PP x t1set
)
Pr = recovery output power
t1 = peak time set (10s max.)
t2 = recovery time (min. 4 x t1)
[W]
[s]
[s]
[ ]
Pr =
t2 x k
Pnom
Pr
k
= safety factor 1.7
0
Time [s]
t1
t2
Practical Example (RACM550-24SG/OF):
Take the RACM550-24SG/OF at 100VAC input voltage and TAMB= 60°C (220W) with
conduction cooling.
Pnom. = refer to derating graphs= 245W with line derating 220W
PP = 550W
220 x (10 + 40) - (550 x 10)
40 x 1.7
t1 = 10s
Pr =
= 80.9W
40s
=
t2
k
= 1.7
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Audio/video, information and communication technology equipment - Safety requirements (CB)
IEC62368-1:2014 2nd Edition
EN62368-1:2014 + A11:2017
UL62368-1:2014
211-700545-000
Audio/video, information and communication technology equipment - Safety requirements
Audio/video, information and communication technology equipment - Safety requirements
(TÜV NRTL)
65.250.19.032.02
pending
CAN/CSA C22.2 No.62368-1:2014
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
Household and similar electrical appliances - Safety - Part 1: General requirements
EN60335-1:2012 + A11:2014
SA1904214L 02001
Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure
EN62233:2008
ANSI/AAMI ES60601-1:2005
CAN/CSA-C22.2 No. 6060-1:14
E314885-D1001-1-A0-
C0-UL
Medical Electric Equipment, General Requirements for Safety and Essential Performance
Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB)
Medical Electric Equipment, General Requirements for Safety and Essential Performance
IEC60601-1:2005, 3rd Edition + AM1:2012
EN60601-1:2006 + A12:2014
pending
pending
IEC61558-1:2005, 2nd Edition + A1:2009
EN61558-1:2005 + A1:2009
Safety of power transformers, power supplies, reactors and similar products -
Part 1: General requirements and tests
Safety of transformers, reactors, power supply units and similar products for supply
voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode
power supply units and transformers for switch mode power supply units (CB)
pending
pending
IEC61558-2-16:2009, 1st Edition + A1:2013
Safety of transformers, reactors, power supply units and similar products for supply
voltages up to 1100 V - Part 2-16: Particular requirements and tests for switch mode
power supply units and transformers for switch mode power supply units (LVD)
EN61558-2-16:2009 + A1:2013
RoHS 2011/65/EU + AM2015/863
RoHS2+
continued on next page
www.recom-power.com
REV.: 0/2020
PA-5
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
EMC Compliance
Electromagnetic compatibility of multimedia equipment - Emission requirements
Electromagnetic compatibility of multimedia equipment - Immunity requirements
Condition
without external filter
Standard / Criterion
EN55032:2015, Class B
EN55035:2017
Information technology equipment - Immunity characteristics -
Limits and methods of measurement
EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Air 8kV, Contact 4kV
3V/m (80-5000MHz)
EN61000-4-2:2009, Criteria A
EN61000-4-3:2006+A2:2010, Criteria A
EN61000-4-4:2012, Criteria A
AC Power Port: 1kV
AC Power Port: L-N 1kV
Surge Immunity
EN61000-4-5:2014, Criteria B
AC Power Port: 3V (0.15-10MHz)
3V to 1V (10-30MHz)
1V (30-80MHz)
Immunity to conducted disturbances, induced by radio-frequency fields
EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity
Voltage Dips and Interruptions
Voltage Dips and Interruptions
Voltage Dips and Interruptions
Voltage Dips and Interruptions
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
Limits of Voltage Fluctuations & Flicker
50Hz/60Hz, 1A/m
Voltage Dips 100% at 50/60Hz
Voltage Dips 30% at 50Hz
Voltage Dips 30% at 60Hz
Voltage Interruptions > 95% at 50Hz
Voltage Interruptions > 95% at 60Hz
Class A
EN61000-4-8:2010, Criteria A
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria A
EN61000-4-11:2004, Criteria B
EN61000-4-11:2004, Criteria C
EN61000-4-11:2004, Criteria B
EN61000-3-2:2014
Clause 5
EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
PCB
FR4, (UL94 V-0)
aluminium
Material
baseplate / case (“/ENC”)
open frame version
enclosed version
127.0 x 76.0 x 38.0mm
150.0 x 87.0 x 45.0mm
Dimension (LxWxH)
open frame version
enclosed version
500g typ.
590g typ.
Weight
Dimension Drawing Open Frame (mm)
127.0
Cꢂꢃꢇ
Cꢂꢃꢊ
Aꢀꢁ
Top View
1
3
2
4
Cꢂꢃꢈ
Cꢂꢃꢉ
Cꢂꢃꢄ
Cꢂꢃꢋ
Cꢂꢃꢌ
2 1
ꢅꢆꢀ
continued on next page
REV.: 0/2020
www.recom-power.com
PA-6
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
Side View
ꢀirꢁꢂꢃꢄ
FC 115.8
FC 5.6
4 x Ø3.5
Bottom View
FC = fixing centers
Tolerance: xx.x= 1.0mm
xx.xx= 0.5mm
Cꢂꢃꢇ
3
1
4
2
AC side
DC side
ꢅꢆꢀ Cꢂꢃꢄ Cꢂꢃꢉ Cꢂꢃꢈ Cꢂꢃꢊ
Cꢂꢃꢌ
Cꢂꢃꢋ
1
3
Aꢀꢁ
Compatible Connector (valid for open frame and enclosed version)
PE (CON1) AC Input (CON4)
# Function Connector # Function Connector # Function Connector # Function Connector # Function Connector
FAN (CON2)
VSB & CTRL (CON3)
Sense (CON6)
1
2
3
4
+5VSB
GND
PS ON 0450 or similar
GND
1
2
3
4
-Sense
NC
+Sense 0450 or similar
NC
TE Connectivity
PIDG series with
positive lock .250EX
1
3
AC/N
AC/L
Molex 09-50-
1031 or similar
1
2
-FAN
Molex 22-01-
Molex 51110-
Molex 51110-
1
PE
+FAN 1022 or similar
NC= No connection
MAIN Output Screw Terminal (CON7/8)
#
Function
-Vout
+Vout
AWG
14-26
14-26
Maximum tightening torque for mounting: 0.3Nm
FC= fixing centers
Tolerance: xx.x= 1.0mm
xx.xx= 0.5mm
CON7
CON8
wire stripping length: 5.0mm
recommended tightening torque: 0.8Nm
continued on next page
www.recom-power.com
REV.: 0/2020
PA-7
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
Dimension Drawing Enclosed Version (mm)
150.0
Cꢀꢁꢋ
Cꢀꢁꢌ
1 2
Cꢀꢁꢂ
Top View
Cꢀꢁꢅ
Cꢀꢁꢄ
Cꢀꢁꢆ
1
3
2
4
Aꢇꢈ
Ø4.5
Ø4.5
embossed logo
Side View
5.0
130.0
10.0
FC 134.5
FC 7.75
4 x Ø4.5
Ø4.5
Bottom View
FC = fixing centers
Tolerance: xx.x= 1.0mm
xx.xx= 0.5mm
continued on next page
REV.: 0/2020
www.recom-power.com
PA-8
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
Dimension Drawing Enclosed Version (mm)
3
1
4
2
DC side
AC side
Cꢀꢁꢋ
Cꢀꢁꢌ
ꢉꢊꢇ
Cꢀꢁꢂ Cꢀꢁꢅ
Cꢀꢁꢄ Cꢀꢁꢆ
1
3
Aꢇꢈ
INSTALLATION AND APPLICATION
Mounting
Forced air conditions as specified are valid for indicated airflow direction only!
vertical
horizontal (standard)
upside down
AC
ꢅC
ꢀirꢁꢂꢃꢄ
ꢀirꢁꢂꢃꢄ
AC
ꢅC
side
side
Notes:
Note12: If module is horizontal or side mounted no derating is required.
If module is mounted vertically or upside down with natural convection cooling, the
power must be derated at least 10%.
For convection cooling, ensure sufficient distance to adjacent components!
With forced air cooling, mounting orientation has no impact on output power.
Device should be fan cooled from DC side.
If thermal conduction cooling is suggested, use of heat sink compound is recom-
mended for improved heat transfer via baseplate.
Block Diagram
PS ON
GND
Isolation
ADJ
+Sense
-Sense
PFC LLC
Controller
Feedback
and Isolation
PWM
Controller
L
Fuse, Inrush
Current Linitation,
Input Filter
+Vout
-Vout
Rectifier +
Bulk Cap
Output
Filter
Rectifier
Switcher
PFC
Boost
N
+Fan
-Fan
PE
Rectifier
Transformer
Feedback
and Isolation
+5VSB
GND
Flyback
Controller
Output
Filter
Rectifier
Transformer
www.recom-power.com
REV.: 0/2020
PA-9
RACM550-G
AC/DC Converter
Specifications (measured @ Ta= 25°C, rated input, rated load unless otherwise stated)
Series
PACKAGING INFORMATION
Parameter
Type
Value
open frame version
enclosed version
134.0 x 86.0 x 45.0mm
155.0 x 92.0 x 50.0mm
Packaging Dimension (LxWxH)
cardboard box
Packaging Quantity
1pcs
-55°C to +85°C
95% RH max.
Storage Temperature Range
Storage Humidity
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢀs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2020
PA-10
相关型号:
©2020 ICPDF网 联系我们和版权申明