60 Watt Open Frame 2“x3“ & 2“x4“ Single Output;
RACM60-24SK/OF
型号: RACM60-24SK/OF
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

60 Watt Open Frame 2“x3“ & 2“x4“ Single Output

文件: 总11页 (文件大小:1533K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 2”x3” optional 2“x4“, low profile design  
• 60W power from -40°C up to +55°C ambient  
• Operating temperature up to +85°C with derating  
• 4 kVAC/1min reinforced isolation  
Features  
AC/DC Converter  
Regulated  
Converter  
• 2MOPP medical certified, B and BF compliant  
• 4000m/5000m (medical/ITE) operating altitude  
• Class B EMC filter built-in  
RACM60-K/OF  
Description  
60 Watt  
3
The multi-purpose, industrial + household + medical grade AC/DC converter series RACM60-K/OF  
delivers 60 Watts of output power from -40°C to +55°C with natural air convection only, and up to  
+85°C with derating or forced cooling. With a clear focus on extended thermal performance for sys-  
tems where space is limited, these 2” x 3” compact modules are designed to gain highest overall  
efficiency levels over the full output load range from universal AC inputs. The RACM60-K/OF has  
ANSI/AAMI/IEC 60601-1 medical safety and EN 60601-1-2 medical EMC certifications and offers  
4kVAC/1 min isolation, 2MOPP and designed to meet B and BF requirements. It is additionally certified  
to IEC/EN62368-1(CB Report) and IEC61558-1/-2-16 for industrial applications and IEC/EN60335-1  
for household appliances. The robust built-in Class B EMC filter has sufficient margin to allow both In-  
stallation Class II or Class I PELV with grounded output. A range of mechanical fixing options makes the  
RACM60 suitable for many different mounting conditions: the standard chassis mount part mates with  
Molex connectors and the /PCB option permits direct installation in printed circuit boards. Additionally, a  
2” x 4” footprint for backwards-compatibility with legacy designs is available on request.  
Open Frame  
2“x3“ & 2“x4“  
Single Output  
Selection Guide  
Part  
Input Voltage  
Range  
Output  
Voltage  
[VDC]  
Output  
Current  
[mA]  
Output  
Power  
[W]  
Efficiency  
typ. (1)  
[%]  
Number  
[VAC]  
RACM60-05SK/OF (2, 3)  
RACM60-12SK/OF (2, 3)  
RACM60-15SK/OF (2, 3)  
RACM60-24SK/OF (2, 3)  
RACM60-36SK/OF (2, 3)  
RACM60-48SK/OF (2, 3)  
80-264  
80-264  
80-264  
80-264  
80-264  
80-264  
5
8000  
5000  
4000  
2500  
1667  
1250  
40  
60  
60  
60  
60  
60  
89  
90  
90  
90  
90  
90  
12  
15  
24  
36  
48  
Notes:  
Note1: Efficiency is tested at nominal input and full load at +25°C ambient  
Model Numbering  
RACM60- __ SK /OF/___-___  
nom. Output Power  
Packaging options (3)  
Connection options (2)  
Case style (2)  
Output Voltage  
E314885  
Single  
CERTIFIED  
EN-60335-1  
Notes:  
Note2: “/OF” = standard 2”x3” open frame version with standard header connectors  
2MOPP  
250VAC  
“/OF/PCB-T”= 2”x3” open frame with PCB mounting pins in single tray packaging (05, 12, 24Vout versions available)  
“/OF/2x4” = 2”x4” open frame version with standard header connectors (12 and 24Vout versions available)  
For other case/connection/footprint options, please contact RECOM technical support  
IEC/EN62368-1 (pending)  
ANSI/AAMI ES60601-1 Ed. 3.1 certified  
CSA/CAN-C22.2 No. 60601-1:14 certified  
IEC/EN60335-1 (pending)  
IEC/EN61558-1 (pending)  
IEC/EN61558-2-16 (pending)  
EN60601-1-2 compliant  
Note3: without suffix, standard single pack (1pcs/cardboard box)  
add suffix “-CTN” for project packaging (4 layers of tray within a carton, for “/OF” only + MOQ= 1152pcs)  
for detail information, refer to “PACKAGING INFORMATION”  
Ordering Examples:  
RACM60-05SK/OF  
RACM60-24SK/OF/PCB-T 24Vout 2” x 3” open frame  
RACM60-12SK/OF/2x4 12Vout 2” x 4” open frame standard header connector  
5Vout 2” x 3” open frame standard header connector  
1pcs/cardboard box  
12pcs/tray packaging  
1pcs/cardboard box  
EN55032 compliant  
EN55035 compliant  
CB Report (pending)  
PCB mounting pins  
RACM60-12SK/OF-CTN 12Vout 2” x 4” open frame standard header connector 48pcs/carton (MOQ= 1152pcs)  
www.recom-power.com  
REV.: 1/2020  
PA-1  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Internal Input Filter  
Nom. Input Voltage  
Pi Type  
100VAC  
240VAC  
80VAC  
120VDC  
264VAC  
370VDC  
Input Voltage Range(3,4)  
115VAC  
230VAC  
1400mA  
600mA  
Input Current  
115VAC  
230VAC  
30A  
60A  
Inrush Current  
cold start  
ErP Standby Mode Conformity  
(Output Load Capability)  
0.5W  
1.0W  
0.3W  
0.7W  
115/230VAC  
Input Power:  
No load Power Consumption  
Input Frequency Range  
Minimum Load  
230VAC  
AC Input  
100mW  
47Hz  
0%  
63Hz  
115VAC  
230VAC  
0.6  
0.5  
Power Factor  
Start-up Time  
Rise Time  
150ms  
100ms  
115VAC  
230VAC  
12ms  
50ms  
Hold-up Time  
Internal Operating Frequency  
100% load at nominal Vin  
5Vout  
others  
100kHz  
200mVp-p  
1% of Vout  
(5)  
Output Ripple and Noise  
20MHz BW  
Notes:  
Note3: The products were submitted for safety files at AC-Input operation (90-264VAC)  
Note4: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 80% at 80VAC)  
Note5: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)  
Efficiency vs. Load  
RACM60-05SK/OF  
others  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
115VAC  
230VAC  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
www.recom-power.com  
REV.: 1/2020  
PA-2  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
REGULATIONS  
Parameter  
Output Accuracy  
Line Regulation  
Condition  
100% load  
Value  
2.0% typ.  
0.05% typ.  
1.5% typ.  
0.5% typ.  
0.1% typ.  
3.0% max.  
500µs max.  
low line to high line  
5Vout  
Load Regulation (6)  
Transient Response  
10% to 100% load  
12, 15Vout  
24, 36, 48Vout  
25% load step change  
recovery time  
Notes:  
Note6: Operation below 10% load will not harm the converter, but specifications may not be met  
Deviation vs. Load  
RACM60-05SK  
RACM60-12SK  
2.0  
1.5  
1.0  
0.5  
0
2.0  
1.5  
1.0  
0.5  
0
-0.5  
-1.0  
-1.5  
-2.0  
-0.5  
-1.0  
-1.5  
-2.0  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
RACM60-15SK  
RACM60-24SK, 36SK, 48SK  
2.0  
1.5  
1.0  
0.5  
0
2.0  
1.5  
1.0  
0.5  
0
-0.5  
-1.0  
-1.5  
-2.0  
-0.5  
-1.0  
-1.5  
-2.0  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
PROTECTIONS  
Parameter  
Type  
Value  
Input Fuse  
internal  
T3.15A, slow blow type  
hiccup, auto recovery  
105% - 120%, auto recovery  
OVCII  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Voltage Category (OVC)  
Over Current Protection (OCP)  
130% - 180%, hiccup mode  
continued on next page  
REV.: 1/2020  
www.recom-power.com  
PA-3  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Parameter  
Type  
Value  
Thermal Shutdown  
Class of Equipment  
Isolation Voltage (safety certified) (7)  
Isolation Resistance  
Isolation Capacitance  
Insulation Grade  
TC point IC 101  
+130°C, restart after cool down  
Class II  
4kVAC  
I/P to O/P  
1 minute  
I/P to O/P, VISO= 500VDC  
I/P to O/P, 100KHz/0.1V  
1Gmin.  
100pF max.  
reinforced  
2MOPP  
Means of Protection  
319VAC working voltage  
Notes:  
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
Operating Temperature Range  
Temperature Coefficient  
Operating Altitude (8)  
Operating Humidity  
Pollution Degree  
@ natural convection 0.1m/s  
refer to “Derating Graph”  
-40°C to +85°C  
0.02%/K  
according to IEC60601-1 / IEC62368-1  
4000m / 5000m  
non-condensing  
95% max.  
PD2  
Vibration  
according to MIL-STD-202G  
10-500Hz, 2G 10min./1cycle, period 60min. along x,y,z axes  
+25°C  
+40°C  
>900 x 103 hours  
>726 x 103 hours  
>42 x 103 hours  
MTBF  
according to MIL-HDBK-217F, G.B.  
nom. Vin= 230VAC, +40°C  
Design Lifetime  
Notes:  
Note8: Recognized by safety agency for safe operation up to 4000/5000m. High altitude operation may impact the performance and lifetime  
Please contact RECOM tech support for advice  
Derating Graph  
(@ Chamber and natural convection 0.1m/s)  
Output power derating for Line-input of less than 90VAC  
(derate linearly from 100% at 90VAC to 80% at 80VAC)  
RACM60-05SK  
others  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
60  
55  
50  
45  
40  
35  
30  
25  
20  
18  
18  
12  
15  
10  
5
115-240VAC nom.  
100VAC nom.  
10  
115-240VAC nom.  
100VAC nom.  
5
0
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110  
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110  
85  
45 55  
75 85  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
www.recom-power.com  
REV.: 1/2020  
PA-4  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report Number  
Standard  
Medical electrical equipment Part 1: General requirements for basic safety and  
essential performance  
E511305-D1000  
-1/A0/C0-UL  
CAN/CSA-C22.2 No. 60601-1:14, 3rd Ed.  
ANSI/AAMI ES60601-1:2005 + A2:2010/R2012  
Audio/Video, information and communication technology equipment - Safety  
requirements (CB Scheme)  
pending  
pending  
pending  
IEC62368-1:2014 2nd Edition  
EN62368-1  
Audio/Video, information and communication technology equipment - Safety  
requirements (LVD)  
Household and similar electrical appliances – Safety – Part 1: General require-  
ments (LVD)  
IEC60335-1:2010 5th Edition + AM1:2013  
EN60335-1:2012 + A11:2014  
Measurement methods for electromagnetic fields of household appliances and  
similar apparatus with regard to human exposure  
EN62233:2008  
IEC61558-1:2005 2nd Edition + A1:2009  
EN61558-1:2005 + A1:2009  
Safety of power transformers, power supplies, reactors & similar products for  
supply voltages up to 1100 V (CB Scheme)  
pending  
pending  
pending  
pending  
Safety of power transformers, power supplies, reactors & similar products for  
supply voltages up to 1100V  
Safety of power transformers, power supplies, reactors & similar products for  
supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme)  
IEC61558-2-16:2009 1st Edition + A1:2013  
Safety of power transformers, power supplies, reactors & similar products for  
supply voltages up to 1100 V Part 2: Particular requirements  
EN61558-2-16:2009 + A1:2013  
RoHS 2011/65/EU + AM2015/863  
RoHS2+  
EMC Compliance (Medical)  
Condition  
Standard / Criterion  
Medical electrical equipment - Part 1-2: General requirements for basic safety  
and essential performance - Collateral standard: Electromagnetic compatibility -  
Requirements and tests  
LCS200402131BE  
EN60601-1-2:2015, Class B, Group 1  
Air: 2, 4, 8, 15kV  
Contact: 2, 4, 8kV  
ESD Electrostatic discharge immunity test  
EN61000-4-2:2009, Criteria B  
9V/m (704-787MHz) 9V/m  
(5100-5800MHz)  
10V/m (80-2700MHz)  
27V/m (380-390MHz)  
28V/m (430-470MHz)  
28V/m (800-960MHz)  
28V/m (1700-1990MHz)  
28V/m (2400-2570MHz)  
Radiated, radio-frequency, electromagnetic field immunity test  
EN61000-4-3:2006+A2:2010, Criteria A  
Fast Transient and Burst Immunity  
Surge Immunity  
AC Port: L-N 2kV  
EN61000-4-4:2012, Criteria B  
EN61000-4-5:2014, Criteria B  
L-N: 1kV  
L (N)-PE: 2kV  
AC Port:  
3Vrms: (0.15-80MHz)  
6Vrms: (ISM and amateur  
radio bands according to  
table 9)  
Immunity to conducted disturbances, induced by radio-frequency fields  
EN61000-4-6:2014, Criteria A  
Power Magnetic Field Immunity  
Voltage Dips and Interruptions  
30A/m  
EN61000-4-8:2010, Criteria A  
EN61000-4-11:2004, Criteria B  
EN61000-3-3:2013  
Dips: 100% (0.5P 1.0P)  
30%  
Interruptions: 100%  
Limits of Voltage Fluctuations & Flicker  
continued on next page  
www.recom-power.com  
REV.: 1/2020  
PA-5  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
EMC Compliance (Industrial according EN55032)  
Electromagnetic compatibility of multimedia equipment - Emission requirements  
Electromagnetic compatibility of multimedia equipment - Immunity requirements  
Condition  
Standard / Criterion  
EN55032:2015, Class B  
EN55035:2017  
LCS200402130BE  
Air: 2, 4, 8kV  
Contact: 2, 4kV  
ESD Electrostatic discharge immunity test  
EN61000-4-2:2009, Criteria B  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity  
3 V/m (80-5000MHz)  
AC Port: L-N 2kV  
EN61000-4-3:2006+A2:2010, Criteria A  
EN61000-4-4:2004+A1:2010, Criteria B  
L-N: 1kV  
L (N)-PE: 2kV  
Surge Immunity  
EN61000-4-5:2014 + A1:2017, Criteria B  
AC Port:  
3Vrms (0.15-80MHz)  
3-1Vrms (10-30MHz)  
1Vrms (30-80MHz)  
Immunity to conducted disturbances, induced by radio-frequency fields  
EN61000-4-6:2014+A1:2015, Criteria A  
EN61000-4-8:2010, Criteria A  
Power Magnetic Field Immunity  
Voltage Dips and Interruptions  
1A/m  
Dips: 100%  
30%  
Interruptions:100%  
EN61000-4-11:2004 +A1:2017, Criteria B  
EN61000-4-11:2004 +A1:2017, Criteria C  
EN61000-4-11:2004 +A1:2017, Criteria C  
Limits of Voltage Fluctuations & Flicker  
EN61000-3-3:2013  
EMC Compliance (Industrial according EN61204-3)  
Condition  
Standard / Criterion  
Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC)  
LCS200402132BE  
EN/IEC61204-3:2018, Class B  
Air: 2, 4, 8kV  
Contact: 2, 4kV  
ESD Electrostatic discharge immunity test  
EN61000-4-2:2009, Criteria B  
10V/m (80-1000MHz)  
3V/m (1400-2000MHz)  
1V/m (2000-2700MHz)  
Radiated, radio-frequency, electromagnetic field immunity test  
EN61000-4-3:2006+A2:2010, Criteria A  
Fast Transient and Burst Immunity  
Surge Immunity  
AC Port: L-N 2kV  
EN61000-4-4:2012, Criteria B  
L-N: 1kV  
L (N)-PE: 2kV  
EN61000-4-5:2014 + A1:2017, Criteria B  
AC Port:  
10Vrms (0.15-80MHz)  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
EN61000-4-6:2014+A1:2015, Criteria A  
EN61000-4-8:2010, Criteria A  
1A/m  
Dips: 100% (0.5P)  
100% (1.0P)  
30% or 20%  
EN61000-4-11:2004 +A1:2017, Criteria B  
EN61000-4-11:2004 +A1:2017, Criteria B  
EN61000-4-11:2004 +A1:2017, Criteria C  
EN61000-4-11:2004 +A1:2017, Criteria C  
Voltage Dips and Interruptions  
Interruptions:100%  
Limits of Voltage Fluctuations & Flicker  
EN61000-3-3:2013  
Limitations on the amount of electromagnetic interference allowed from digital and  
electronic devices  
FCC 47 CFR Part 15 Subpart B  
Limitations on the amount of electromagnetic interference allowed from digital and  
electronic devices, industrial, scientific, and medical equipment  
FCC 47 CFR Part 18  
DIMENSION AND PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
Material  
PCB  
FR4 (UL94-V0)  
“/OF” type  
“/OF/PCB” type  
“/OF/2x4” type  
78.4 x 53.0 x 31.5mm  
78.4 x 53.0 x 35.4mm  
101.6 x 53.0 x 31.5mm  
111g typ.  
Dimension (LxWxH)  
Weight  
“/OF” and “/OF/PCB” types  
“/OF/2x4” type  
120g typ.  
continued on next page  
REV.: 1/2020  
www.recom-power.com  
PA-6  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Dimension Drawing “/OF” (mm)  
AC Input Side View  
CON1  
Top View  
5.0  
6x 1.14 5.2  
68.3  
Front View  
DC Output Side View  
CON2  
78.4  
FC 34.9  
FC 34.9  
IC101  
Connector Information  
Function  
AC Input (CON1)  
#
Terminal  
1
3
VAC in (N)  
VAC in (L)  
3 Pins (Pin2 removed)  
with 3.96mm pitch  
Bottom View  
DC Output (CON2)  
4x Ø3.2  
4,5  
-VDC out  
4 Pins  
6,7 +VDC out  
with 3.96mm pitch  
FC= fixing centers  
Compatible Connector  
Housing  
ꢀeneraꢁ toꢁeranceꢂ according to ꢃꢄꢅ ꢆꢇꢈꢉꢊm  
ꢋtaꢌꢁe ꢍor reꢍerence onꢁꢎꢏ  
Molex 41695 Series or equivalent  
Crimp Terminal  
Molex 2478 Series or equivalent  
Dimension ranꢀe  
0.5 - 6 mm  
ꢁolerances  
0.1 mm  
0.2 mm  
0.3 mm  
0.5 mm  
6 - 30 mm  
30 - 120 mm  
120 - 400 mm  
continued on next page  
www.recom-power.com  
REV.: 1/2020  
PA-7  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Dimension Drawing “/OF/2x4” (mm)  
CON3  
Top View  
5.6  
6x 1.14  
5.8  
90.23  
Front View  
Connector Information  
Function  
AC Input (CON1)  
VAC in (N) 3 Pins (Pin2 removed)  
#
Terminal  
101.6  
1
3
VAC in (L)  
with 3.96mm pitch  
FC 47.6  
FC 47.6  
DC Output (CON2)  
4,5 -VDC out  
6,7 +VDC out with 3.96mm pitch  
4 Pins  
IC101  
FE (CON3)  
functional  
earth  
8
fast on  
FC= fixing centers  
Bottom View  
Compatible connector please refer to “/OF” drawing)  
4x Ø4.0  
Compatible Connector  
Housing  
Molex 41695 Series or equivalent  
Crimp Terminal  
DC Output Side View  
Molex 2478 Series or equivalent  
AC Input Side View  
CON2  
CON1  
ꢀeneraꢁ toꢁeranceꢂ according to ꢃꢄꢅ ꢆꢇꢈꢉꢊm  
ꢋtaꢌꢁe ꢍor reꢍerence onꢁꢎꢏ  
Dimension ranꢀe  
0.5 - 6 mm  
6 - 30 mm  
30 - 120 mm  
120 - 400 mm  
ꢁolerances  
0.1 mm  
0.2 mm  
0.3 mm  
0.5 mm  
continued on next page  
www.recom-power.com  
REV.: 1/2020  
PA-8  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Dimension Drawing “/OF/PCB” (mm)  
AC Input Side View  
Top View  
CON1  
5.0  
5.2  
DC Output Side View  
Front View  
CON2  
68.26  
78.4  
6x 1.14  
Pin-header Information  
Function  
FC 34.9  
FC 34.9  
#
Terminal  
AC Input (CON1)  
IC101  
1
3
VAC in (N)  
VAC in (L)  
3 Pins (Pin2 removed)  
with 3.96mm pitch  
DC Output (CON2)  
4,5  
-VDC out  
6,7 +VDC out  
4 Pins  
with 3.96mm pitch  
Bottom View  
FC= fixing centers  
4x Ø3.2  
ꢀeneraꢁ toꢁeranceꢂ according to ꢃꢄꢅ ꢆꢇꢈꢉꢊm  
ꢋtaꢌꢁe ꢍor reꢍerence onꢁꢎꢏ  
Dimension ranꢀe  
0.5 - 6 mm  
6 - 30 mm  
30 - 120 mm  
120 - 400 mm  
ꢁolerances  
0.1 mm  
0.2 mm  
0.3 mm  
0.5 mm  
www.recom-power.com  
REV.: 1/2020  
PA-9  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
APPLICATION AND INSTALLATION  
Mounting  
horizontal (standard)  
vertical  
AC  
DC  
airflow  
If module is mounted vertical or upside-down with natural convection cooling,  
the power must be derated 10%.  
upside-down  
airflow  
AC  
DC  
Blockdiagram (“/OF” and “/OF/PCB”)  
T3.5A  
+V  
L
Active  
Rectification  
Input  
Filter  
Output  
Filter  
Rectifier  
N
-V  
Feedback  
Snubber  
Flyback Controller  
Rectification  
Controller+  
Feedback  
continued on next page  
www.recom-power.com  
REV.: 1/2020  
PA-10  
RACM60-K/OF  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
APPLICATION AND INSTALLATION  
Blockdiagram (“/OF/2x4”)  
T3.5A  
+V  
-V  
L
Active  
Rectification  
Input  
Filter  
Output  
Filter  
Rectifier  
T3.5A  
N
Feedback  
FE  
Snubber  
Flyback Controller  
Rectification  
Controller+  
Feedback  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
“/OF” type  
“/OF/2x4” type  
65.0 x 55.0 x 95.0mm  
65.0 x 50.0 x 110.0mm  
cardboard box (single pack)  
Packaging Dimension (LxWxH)  
“/OF/PCB-T” type  
“/OF-CTN” type  
single tray (carton)  
365.0 x 210.0 x 56.0mm  
375.0 x 220.0 x 245.0mm  
1pcs  
tray in carton (project pack)  
“/OF” type and “/OF/2x4” type  
Package Unit  
“/OF/PCB-T” type  
12pcs  
“/OF-CTN” type, MOQ= 1152pcs  
48pcs  
Storage Temperature Range  
Storage Humidity  
-40°C to +90°C  
95% max.  
non-condensing  
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 1/2020  
PA-11  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY