RP100H-11005SRW [RECOM]

4:1 Wide Input Range;
RP100H-11005SRW
型号: RP100H-11005SRW
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

4:1 Wide Input Range

文件: 总15页 (文件大小:2886K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 4:1 Wide Input Range  
Features  
• 3kVAC Reinforced Insulation for 110Vin  
2.25kVDC Basic Insulation for 24Vin & 48Vin  
• Efficiency up to 93%  
• No Minimum Load Required  
• EN50155, IEC/EN60950-1 & UL60950-1 Certified  
DC/DC Converter  
Regulated  
Converters  
RP100H-RW  
Description  
100 Watt  
The half-brick RP100H series DC/DC converters are designed for railway rolling stock and high voltage battery  
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to  
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base-  
plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).  
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock  
and vibration environments. The converters are EN50155, UL60950 and IEC/EN60950 certified. The RP100H-RW  
series have a three year warranty.  
Half Brick  
Single Output  
Selection Guide  
Part Number  
Input  
Output  
Output Input(1) Output Efficiency(1) Max. Capacitive  
Voltage Range Voltage Current Current Power  
typ.  
[%]  
Load  
[µF]  
[VDC]  
9-36  
[VDC]  
5
[mA]  
20000  
8400  
6700  
4200  
2100  
20000  
8400  
6700  
4200  
2100  
20000  
8400  
6700  
4200  
2100  
[mA]  
4480  
4666  
4601  
4666  
4666  
2240  
2333  
2300  
2333  
2307  
1010  
1018  
1015  
1018  
1007  
[W]  
100  
101  
100  
101  
101  
100  
101  
100  
101  
101  
100  
101  
100  
101  
101  
RP100H-2405SRW  
RP100H-2412SRW  
RP100H-2415SRW  
RP100H-2424SRW  
RP100H-2448SRW  
RP100H-4805SRW  
RP100H-4812SRW  
RP100H-4815SRW  
RP100H-4824SRW  
RP100H-4848SRW  
93  
90  
91  
90  
90  
93  
90  
91  
90  
90  
93  
90  
91  
90  
90  
40000  
7000  
4460  
1750  
430  
40000  
7000  
4460  
1750  
430  
40000  
7000  
4460  
1750  
430  
9-36  
9-36  
9-36  
9-36  
16.5-75  
16.5-75  
16.5-75  
16.5-75  
16.5-75  
12  
15  
24  
48  
5
12  
15  
24  
48  
5
E196683  
RP100H-11005SRW 43-160  
RP100H-11012SRW 43-160  
RP100H-11015SRW 43-160  
RP100H-11024SRW 43-160  
RP100H-11048SRW 43-160  
12  
15  
24  
48  
EN50155 Certified  
IEC/EN60950-1 Certified  
UL60950-1 Certified  
Notes:  
Note1:  
Efficiency is tested by nominal Vin, full load and at 25°C.  
Model Numbering  
RP100H-__ __SRW/_ _  
Input Voltage  
Output Voltage  
Single  
Package(3)  
CTRL Logic(2)  
Ordering Examples  
RP100H-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function  
RP100H-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function  
RP100H-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, premounted Heat-sink  
Notes:  
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)  
or add suffix “N” instead for negative logic (0=ON, 1=OFF)  
Note3: add suffix “-HC” for premounted Heat-sink  
(compatible with all other suffixes)  
www.recom-power.com  
REV.: 1/2016  
PB-1  
RP100H-RW  
DC/DC Converter  
Series  
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Internal Input Filter  
Pi-Type  
nom Vin = 24V  
nom Vin = 48V  
nom Vin = 110V  
9VDC  
16.5VDC  
43VDC  
24VDC  
48VDC  
110VDC  
36VDC  
75VDC  
160VDC  
Input Voltage Range  
Input Surge Voltage  
Quiescent Current  
Start-up time  
Vin = 24V, 1s max.  
Vin = 48V, 1s max.  
Vin = 110V, 1s max.  
50VDC  
100VDC  
185VDC  
Vin = 24V  
Vin = 48V  
Vin = 110V  
25mA  
15mA  
35mA  
25mA  
10mA  
Power up  
Remote ON/OFF  
75ms  
75ms  
Vin = 24V, Vin =48V  
Vin = 110V  
225kHz  
270kHz  
250kHz  
300kHz  
275kHz  
330kHz  
Internal Operating Frequency  
Minimum Load  
0%  
Measured by 20MHz BW  
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 5 Vout  
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 12, 15Vout  
75mVp-p  
100mVp-p  
200mVp-p  
300mVp-p  
Ripple and Noise  
with a 4.7µF/50V X7R MLCC  
with a 2.2µF/100V X7R MLCC  
24Vout  
48Vout  
DC-DC ON  
DC-DC OFF  
9VDC  
8.1VDC  
Vin = 24V  
Vin = 48V  
7.3VDC  
15.5VDC  
33.0VDC  
DC-DC ON  
DC-DC OFF  
18VDC  
16.3VDC  
Under Voltage Lockout (UVLO)  
DC-DC ON  
DC-DC OFF  
43VDC  
36.0VDC  
Vin = 110V  
Open or 3.0V < Vr < 12V  
Short or 0V < Vr < 1.2V  
DC-DC ON  
DC-DC OFF  
Positive Logic  
Negative Logic  
ON/OFF Control  
Short or 0V < Vr < 1.2V  
Open or 3.0V < Vr < 12V  
DC-DC ON  
DC-DC OFF  
-0.5mA  
-20%  
1mA  
Input current of CTRL pin  
Standby Current  
Output Trim  
3mA  
+10%  
10%  
% of nom Vout  
Remote Sense  
RP100H-2405SRW  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
100% Load  
50% Load  
25% Load  
9Vin  
24Vin  
36Vin  
12  
15  
18  
21  
24  
27  
30  
33  
9
36  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Input Voltage [V]  
Output Current [%]  
continued on next page  
REV.: 1/2016  
PB-2  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted  
RP100H-2405SRW  
Typical Output Ripple and Noise/full load  
Power Dissipation vs. Output Current  
18  
15  
12  
9
6
9Vin  
24Vin  
36Vin  
3
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Output Current [%]  
ON/OFF Control Start-up Rise Characteristic  
Power up Start-up Characteristic  
RP100H-4805SRW  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
100% Load  
50% Load  
25% Load  
16.5Vin  
48Vin  
75Vin  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
24  
30  
36  
42  
48  
54  
60  
66  
16.5  
75  
72  
Output Current [%]  
Input Voltage [V]  
continued on next page  
REV.: 1/2016  
www.recom-power.com  
PB-3  
RP100H-RW  
DC/DC Converter  
Series  
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted  
RP100H-4805SRW  
Power Dissipation vs. Output Current  
Typical Output Ripple and Noise/full load  
18  
15  
12  
9
6
3
16.5Vin  
48Vin  
75Vin  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Output Current [%]  
ON/OFF Control Start-up Rise Characteristic  
Power up Start-up Characteristic  
RP100H-11005SRW  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
100% Load  
50% Load  
25% Load  
43Vin  
110Vin  
160Vin  
43  
60  
65  
80  
95  
110 125 140 155 160  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Input Voltage [V]  
Output Current [%]  
continued on next page  
REV.: 1/2016  
PB-4  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications measured @ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted  
RP100H-11005SRW  
Power Dissipation vs. Output Current  
Typical Output Ripple and Noise  
18  
15  
12  
9
6
43Vin  
110Vin  
160Vin  
3
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Output Current [%]  
ON/OFF Control Start-up Rise Characteristic  
Power up Start-up Characteristic  
OUTPUT TRIM  
Output Voltage Trimming  
RP100H-RW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim  
resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may  
slightly vary; they also can be calculated with below shown equation.  
TRIM UP  
TRIM DOWN  
TRIM  
-Sense  
R
R
2
1
+Sense  
TRIM  
continued on next page  
REV.: 1/2016  
www.recom-power.com  
PB-5  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
OUTPUT TRIM  
Trim Calculation  
Vout  
DVout  
R1  
=
=
=
=
Output Voltage  
100*Vout+DVout * Vout)  
1.225*DVout  
(100+2DVout)  
DVout  
R1 = q  
R2 = q  
-
rkΩ  
Output Voltage Trim in %  
trim up resistor  
R2  
trim down resistor  
100  
- 2rkΩ  
DVout  
Practical Example:  
Trim Up:  
Vout = 5V, DVout = 10% (5.5V)  
100*Vout+DVout * Vout)  
R1 = q  
(100+2DVout)  
DVout  
100*5 +10*5 100+2*10  
-
rk=  
-
= 44.89 - 12 = 33.2kΩ  
1.225*DVout  
1.225*10  
10  
Trim down:  
Vout = 5V, DVout = -10% (4.5V)  
100  
100  
10  
R2 = q  
- 2rk=  
- 2 = 8.06kΩ  
DVout  
RP100H-xx05SRW  
Trim up  
Vout =  
R1 =  
1
2
3
4
5
6
7
8
9
10  
%
5.05  
309  
5.10  
158  
5.15  
105  
5.20  
78.7  
5.25  
63.4  
5.30  
53.6  
5.35  
46.4  
5.4  
40.2  
5.45  
36.5  
5.50  
33.2  
Volts  
KOhms  
RP100H-xx12SRW  
Trim up  
Vout =  
R1 =  
1
2
3
4
5
6
7
8
9
10  
%
12.12  
887  
12.24  
453  
12.36  
301  
12.48  
226  
12.60  
182  
12.72  
154  
12.84  
133  
12.96  
118  
13.08  
105  
13.20  
95.3  
Volts  
KOhms  
RP100H-xx15SRW  
Trim up  
Vout =  
R1 =  
1
2
3
4
5
6
7
8
9
10  
%
15.15  
1130  
15.30  
576  
15.45  
383  
15.60  
294  
15.75  
237  
15.90  
196  
16.05  
169  
16.20  
150  
16.35  
137  
16.50  
124  
Volts  
KOhms  
RP100H-xx24SRW  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
%
24.24  
1870  
24.48  
953  
24.72  
634  
24.96  
487  
25.20  
392  
25.44  
324  
25.68  
280  
25.92  
249  
26.16  
226  
26.40  
205  
Volts  
KOhms  
RP100H-xx48SRW  
Trim up  
Vout =  
R1 =  
1
2
3
4
5
6
7
8
9
10  
%
48.48  
3830  
48.96  
1960  
49.44  
1300  
49.92  
988  
50.40  
806  
50.88  
681  
51.36  
576  
51.84  
511  
52.32  
464  
52.80  
422  
Volts  
KOhms  
Trim Down all Vout‘s  
Trim down  
1
2
3
4
5
6
7
8
9
10  
%
R2 =  
97.6  
47.5  
31.6  
23.2  
17.8  
14.7  
12.1  
10.5  
9.09  
8.06  
KOhms  
Trim down  
R2 =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
%
7.15  
6.34  
5.76  
5.11  
4.64  
4.22  
3.92  
3.57  
3.24  
3.01  
kOhms  
continued on next page  
PB-6  
REV.: 1/2016  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
Remote Sense  
R
W1  
+V  
out  
The output voltage can be adjusted by both trim and remote sense. The  
maximum combined adjustment range 10%. Derate the maximum out-  
put power if using the trim or sense function.  
+Sense  
R
R
1
2
R
R
... wire losses +  
... wire losses -  
Trim  
W1  
W2  
1
R ... trim up resistor  
-Sense  
R ... trim down resistor  
2
-V  
out  
(GND)  
R
W2  
REGULATIONS  
Parameter  
Condition  
Value  
Output Accuracy  
Line Regulation  
Load Regulation  
Transient Response  
1.0%  
low line to high line at full load  
0% to 100% load  
0.1%  
0.1%  
25% load step change  
200µs typ.; 250µs max.  
Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin  
RP100H-2405SRW RP100H-4805SRW  
RP100H-11005SRW  
www.recom-power.com  
REV.: 1/2016  
PB-7  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
PROTECTIONS  
Parameter  
Condition  
below 100mΩ  
% of nom. Vout  
Value  
continuous, automatic recovery  
115%-130%, Hiccup Mode  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
24Vin, 48Vin  
110Vin  
120%-150%, Hiccup Mode  
150% typ., Hiccup Mode  
Over Load Protection (OLP)  
% Iout rated  
Over Temperature Protection (OTP)  
+110°C to +120°C  
I/P to O/P  
I/P or O/P to Case  
3kVAC/1minute  
1.5kVAC/1minute  
110Vin  
Isolation Voltage  
I/P to O/P  
I/P or O/P to Case  
2.25kVDC/1minute  
1.6kVDC/1minute  
24Vin, 48Vin  
Isolation Resistance  
Isolation Capacitance  
500 VDC  
1Gmin.  
2500pF max.  
110 Vin  
24Vin, 48Vin  
Reinforced Insulation  
Basic Insulation  
Isolation Grade  
Notes:  
Note4: An input fuse is required if the mains supply isn’t over-current protected. Recommended fuse: T35A slow blow.  
ENVIRONMENTAL  
Parameter  
Operating Case Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
Condition  
Value  
-40°C to +105°C  
105°C  
0.02%/°C max.  
vertical direction by natural convection (0.1m/s) without Heat-sink  
vertical direction by natural convection (0.1m/s) with Heat-sink  
6.7°C/W  
4.7°C/W  
Thermal Impedance  
Operating Humidity  
Pollution Degree  
Shock  
5% - 95% RH  
PD2  
according to EN61373 standard  
according to MIL-STD-810F standard  
according to EN61373 standard  
according to EN45545-2, 2013 standard  
408.7 x 103 hours  
Thermal Shock  
Vibration  
Fire protection on railway vehicles  
MTBF  
according to MIL-HDBK-217F standard, 25°C  
Thermal Calculation  
Rthcase-ambient = 6.7°C/W (vertical)  
Rthcase-ambientHC = 4.7°C/W (vertical)  
Tcase  
=
=
=
=
=
=
=
Case Temperature  
Environment Temperature  
Internal losses  
Input Power  
Output Power  
Tambient  
Pdissipation  
PIN  
POUT  
h
Tcase - Tambient  
Pdissipation  
Rthcase-ambient  
=
Efficiency under given Operating Conditions  
Thermal Impedance  
POUTapp  
h
Pdissipation = PIN - POUT  
=
- POUTapp  
Rthcase-ambient  
Practical Example:  
Take the RP100H-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without  
airflow.  
Effmin = 91% @ Vnom  
without Heat-sink  
with Heat-sink  
Tcasemax - Tamb  
POUT = 100W  
Tcasemax - Tamb  
Rth =  
105-T  
105-Tamb  
4.95W  
amb  
--> 6.7°C/W =  
RthHC  
=
--> 4.7°C/W =  
POUTapp = 100 x 0.5 = 50W  
Pdissipation  
4.95W  
Pdissipation  
h = 91% (Efficiency vs. Load Graph)  
Tamb = 72°C  
TambHC = 82°C  
50  
0.91  
Pdissipation  
=
- 50 = 4.95W  
continued on next page  
REV.: 1/2016  
PB-8  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
Derating Graph(5)  
(@ Chamber - tested with forced convection)  
RP100H-2405SRW  
RP100H-2405SRW-HC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
0.5m/s  
1m/s  
1.5m/s  
2m/s  
natural convection  
0.5m/s  
1m/s  
1.5m/s  
2m/s  
2.5m/s  
2.5m/s  
-40 -20  
0
20 40  
60 80 100 120  
-40 -20  
0
20 40  
60 80 100 120  
67  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
RP100H-4805SRW  
RP100H-4805SRW-HC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
0.5m/s  
1m/s  
1.5m/s  
2m/s  
natural convection  
0.5m/s  
1m/s  
1.5m/s  
2m/s  
2.5m/s  
2.5m/s  
-40 -20  
0
20 40  
60 80 100 120  
65  
-40 -20  
0
20 40  
60  
100 120  
80  
71  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
RP100H-11005SRW  
RP100H-11005SRW-HC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
0.5m/s  
1m/s  
1.5m/s  
2m/s  
natural convection  
0.5m/s  
1m/s  
1.5m/s  
2m/s  
2.5m/s  
2.5m/s  
-40 -20  
0
20 40  
60 80 100 120  
-40 -20  
0
20 40  
60 80 100 120  
50  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
Notes:  
Note5: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-  
number not shown here please contact our technical support service at techsupportAT@recom-power.com  
www.recom-power.com  
REV.: 1/2016  
PB-9  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
UL60950-1, 2nd Edition, 2014  
CSA C22.2 No. 60950-1-07, 2014  
Information Technology Equipment, General Requirements for Safety  
E196683  
TW1608033-001, TW1608036-001,  
TW1608037-001, TW1608079-001  
IEC60950-1, 2nd Edition. 2005  
EN60950-1, 1st Edition, 2006  
IEC/EN Information Technology Equipment - General Requirments for Safety  
Railway Applications - Electrical Equipment used on rolling stock  
16A081501E-C  
EN50155, 2007  
EMI Compliance  
Condition  
Standard / Criterion  
Information technology equipment - Radio disturbance characteristics - Limits and  
methods of measurement  
EN55022, Class A and Class B  
with external components  
Industrial, scientific and medical equipment - Radio frequency disturbance  
characteristics - Limits and methods of measurement  
EN55011, Class A and Class B  
ESD Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity(6)  
Air 8kV and Contact 6kV  
20 V/m  
EN61000-4-2, Criteria A  
EN61000-4-3, Criteria A  
EN61000-4-4, Criteria A  
EN61000-4-5, Criteria A  
EN61000-4-6, Criteria A  
EN61000-4-8, Criteria A  
2kV  
Surge Immunity(6)  
EN55024 & EN50155 2kV  
10 Vr.m.s  
100A/m continuous; 1000A/m 1s  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
Notes:  
Note6: An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.  
The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel.  
Recom suggest: Nippon Chemi-con KY series, 220µF/100V.  
The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel.  
Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V  
EMI Filtering according to EN55022/11 Class A and EN50121-1 (24Vin and 48Vin)  
C10  
L1  
Fuse  
+V  
IN  
C1  
C2  
C3  
C7  
C8  
C4  
C5  
C6  
Case  
-V  
IN  
C13  
C9  
C12  
C11  
Shield Plane  
C8, C9, C10,  
C11, C13  
MODEL  
C1, C2, C4  
C3, C6, C7  
C12  
L1  
470µF, 50V  
4.7µF, 50V 1000pF, 3kV  
3300pF, 3kV  
1808 MLCC  
156µH  
CMC  
RP100H-24xxSRW  
RP100H-48xxSRW  
Al cap. (lie down) Chemi-con KY 1812 MLCC 1808 MLCC  
220µF, 100V 2.2µF, 100V 1000pF, 3kV  
Al cap. (lie down) Chemi-con KY 1812 MLCC 1808 MLCC  
1000pF, 3kV  
1808 MLCC  
224µH  
CMC  
continued on next page  
REV.: 1/2016  
PB-10  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
RP100H-2405SRW Conducted Emission EN55022 Class A  
RP100H-4805SRW  
Conducted Emission EN55022 Class A  
EMI Filtering according to EN55022/11 Class A and EN50121-1 (110Vin)  
C18  
L1  
Fuse  
+V  
IN  
C1  
C2  
C5  
C3  
C4  
C8  
C9  
C10  
Case  
-V  
IN  
C11  
C12  
C17  
C20  
C14  
C16  
C15  
C13  
C19  
C7  
C6  
Shield Plane  
C6, C11, C12, C13, C14,  
C15, C16, C19, C20  
1000pF, 5kV  
MODEL  
C1, C2, C8  
C10  
C17, C18  
L1  
100µF, 250V  
Al cap. (lie down) Rubycon BXF 1812 MLCC  
F, 250V  
2200pF  
TDK CD series Y1  
1219µH  
CMC  
RP100H-110xxSRW  
1808 MLCC  
continued on next page  
www.recom-power.com  
REV.: 1/2016  
PB-11  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
RP100H-11005SRW  
Conducted Emission EN55022 Class A  
EMI Filtering according to EN55022/11 Class B (24Vin and 48Vin)  
C11  
L1  
L2  
Fuse  
+V  
IN  
C3  
C4  
C1  
C2  
C5  
C6  
C7 C8  
Case  
-V  
IN  
C9  
C10  
C13  
C15  
C12  
C14  
Shield Plane  
C2, C4,  
C5, C7, C8  
MODEL  
C1, C3, C6  
C9, C10  
C11  
C12  
C13, C14  
C15  
L1  
470µF, 50V  
4.7µF, 50V 10nF, 2kV 1000pF, 3kV 4700pF, 3kV 10nF, 2kV  
156µH  
CMC  
RP100H-24xxSRW  
N/A  
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC 1812 MLCC 1812 MLCC  
220µF, 100V 2.2µF, 100V 10nF, 100V 2200pF, 3kV 4700pf, 3kV 10nF, 2kV 1000pF, 3kV  
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC 1812 MLCC 1812 MLCC 1808 MLCC  
224µH  
CMC  
RP100H-48xxSRW  
RP100H-2405SRW  
Conducted Emission EN55022 Class B  
continued on next page  
PB-12  
REV.: 1/2016  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
RP100H-4805SRW  
Conducted Emission EN55022 Class B  
EMI Filtering according to EN55022/11 Class B (110Vin)  
C15  
L1  
L2  
Fuse  
+V  
IN  
C1  
C2  
C5  
C3  
C7  
C4  
C6  
C10 C11 C12  
Case  
-V  
IN  
C9  
C14  
C16  
C18  
C8  
C13  
C20  
C22  
C17  
C21  
C19  
Shield Plane  
C2 , C5,  
C23, C24  
C6, C7, C8, C9, C13, C14,  
C17, C18, C19, C20, C21, C22  
MODEL  
C1, C3, C10  
C4, C11, C12  
C15, C16  
L1  
L2  
F, 250V  
1812 MLCC  
1000pF, 5kV  
1808 MLCC  
RP100H-110xxSRW  
N/A  
150µF, 200V  
Al cap. (lie down)  
Chemi-con KY  
C2, C4, C11,  
C12  
C8, C9, C13, C14, C17, C18 , C19,  
C20, C21, C22, C23, C24  
2200pF  
TDK CD series Y1  
1219µH  
CMC  
521µH  
CMC  
C5, C6, C7, C19  
1µF/250V  
1812 MLCC  
100pF/250VAC  
1808 MLCC  
RP100H-11048SRW  
N/A  
RP100H-11005SRW  
Conducted Emission EN55022 Class B  
www.recom-power.com  
REV.: 1/2016  
PB-13  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
DIMENSIONS and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
24Vin, 48Vin  
110Vin  
Metal  
Plastic  
Case  
24Vin, 48Vin  
110Vin  
FR4 PCB  
Aluminium  
Material  
Baseplate  
Potting  
Silicone (UL94 V-0)  
without Heat-sink  
with Heat-sink  
61.0 x 57.9 x 12.7mm  
61.0 x 57.9 x 24.13mm  
Packaging Dimension (LxWxH)  
Packaging Weight  
without Heat-sink  
with Heat-sink  
105g  
157g  
Dimension Drawing (mm)  
24Vout, 48Vout  
57.9  
61.0  
M3  
Ø2.0  
Ø1.0  
4.8  
5
4
3
6
7
8
Bottom View  
Pin Connections  
2
1
Pin #  
Single  
+Vin  
9
1
2
3
4
5
6
7
8
9
CTRL  
Case  
4xM3  
FC 48.26  
57.9  
-Vin  
-Vout  
-Sense  
Trim  
110Vout  
61.0  
+Sense  
+Vout  
Ø2.0  
M3  
Ø1.0  
FC= Fixing Centers for Heat-sink  
Pin Pitch Tolerance 0.25mm  
Pin Dimension Tolerance 0.1mm  
XX.X 0.5mm  
4.8  
XX.XX 0.25mm  
5
4
3
6
7
8
Bottom View  
2
1
9
4xM3  
FC 48.26  
continued on next page  
REV.: 1/2016  
PB-14  
www.recom-power.com  
RP100H-RW  
DC/DC Converter  
Series  
Specifications (measured @ ta= 25°C, nominal input voltage, full load and after warm-up)  
110Vout with Heat Sink  
57.9  
48.26  
Notes:  
Note7: Max. tightening torque for Heat Sink: 0.34Nm  
4xM3  
Ø2.0  
Ø1.0  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
without Heat-sink  
with Heat-sink  
157.0 x 88.0 x 12.8mm  
157.0 x 88.0 x 24.8mm  
Packaging Dimension  
Tray  
Packaging Quantity  
2pcs.  
-55°C to +125°C  
5% - 95% RH  
Storage Temperature Range  
Storage Humidity  
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written  
consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer  
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 1/2016  
PB-15  

相关型号:

RP100H-11005SRW/N

DC DC CONVERTER 5V 100W
ETC

RP100H-11005SRW/N-HC

CONV DC/DC 100W 43-160VIN 05VOUT
ETC

RP100H-11005SRW/P

CONV DC/DC 100W 43-160VIN 05VOUT
ETC

RP100H-11005SRW/P-HC

CONV DC/DC 100W 43-160VIN 05VOUT
ETC

RP100H-11012SRW

4:1 Wide Input Range
RECOM

RP100H-11012SRW/N

CONV DC/DC 101W 43-160VIN 12VOUT
ETC

RP100H-11012SRW/N-HC

CONV DC/DC 101W 43-160VIN 12VOUT
ETC

RP100H-11012SRW/P

DC DC CONVERTER 12V 101W
ETC

RP100H-11012SRW/P-HC

CONV DC/DC 101W 43-160VIN 12VOUT
ETC

RP100H-11015SRW

4:1 Wide Input Range
RECOM

RP100H-11015SRW/N

CONV DC/DC 100W 43-160VIN 15VOUT
ETC

RP100H-11015SRW/N-HC

CONV DC/DC 100W 43-160VIN 15VOUT
ETC