RP15-2405DEW [RECOM]
15 Watt Single & Dual Output; 15瓦单和双输出![RP15-2405DEW](http://pdffile.icpdf.com/pdf1/p00066/img/icpdf/RP15-2405_348649_icpdf.jpg)
型号: | RP15-2405DEW |
厂家: | ![]() |
描述: | 15 Watt Single & Dual Output |
文件: | 总4页 (文件大小:97K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
● 4:1 Wide Input Voltage Range
● 15 Watts Output Power
● 1.6kVDC Isolation
POWERLINE
Features
DC/DC-Converter
● Fixed Operating Frequency
● Six-Sided Continuous Shield
● International Safety Standard Approvals
● Standard 50.8 x40.6x10.2mm Package
● Efficiency to 82%
RP15-
S_DEW
Series
Selection Guide 24V and 48V Input Types
Part Number
Input
Range
Output
Voltage
Output
Current
Input (4) Efficiency(5) Capacitive(6)
Current
Load max.
VDC
9-36
VDC
5
mA
mA
%
µF
RP15-2405SEW
RP15-2412SEW
RP15-2415SEW
RP15-4805SEW
RP15-4812SEW
RP15-4815SEW
RP15-2405DEW
RP15-2412DEW
RP15-2415DEW
RP15-4805DEW
RP15-4812DEW
RP15-4815DEW
3000
1250
1000
3000
1250
1000
1500
625
822
801
801
411
401
401
822
801
801
411
401
401
79
82
82
80
82
82
80
82
82
80
82
82
6800
890
15 Watt
9-36
12
15
5
9-36
570
&
Single
Dual
18-75
18-75
18-75
9-36
6800
890
12
15
5
570
Output
1700
300
9-36
12
15
5
9-36
500
200
18-75
18-75
18-75
1500
625
1700
300
12
15
500
200
Derating-Graph (Ambient Temperature)
RP15-4805SEW
125
100
75
Natural Convection
50
25
0
-25 -10 0
50
70 80 90 100
60
-40
Ambient Temperature Range (°C)
RP15-4805SEW With Heat Sink
125
100
75
Natural Convection
50
25
0
-40 -25 -10 0
50 60
80 90 100
70
Ambient Temperature Range (°C)
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at info@recom-development.at
224
April-2005
www.recom-international.com
POWERLINE
RP15-S_DEW
Series
DC/DC-Converter
Typical Characteristics
RP15-4805SEW
RP15-4805SEW
Efficiency VS Output load
Efficiency VS Input Voltage
83
82
83
82
81
80
79
78
77
76
70
65
81
80
79
78
77
76
75
74
50
0.5
73
36 40
2
1
1.5
2.5
3
60 65
70 75
45
50
55
Output Load (A)
Input Voltage (V)
Specifications (typical at nominal input and 25ꢀC unless otherwise noted)
Input Voltage Range
24V nominal input
9-36VDC
48V nominal input
18-75VDC
Input Filter
Pi Type
Input Surge Voltage (100 ms max.)
24V Input
48V Input
50VDC
100VDC
Input Reflected Ripple (nominal Vin and full load)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
20mAp-p
20ms typ.
DC-DC ON
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
20mA
DC-DC OFF
Nominal input
Remote OFF input current
Output Power
15W max.
2%
Output Voltage Accuracy (full Load and nominal Vin)
Output Voltage Adjustability
10%
Minimum Load (see Note 1)
10% of FL
0.5%
Line Regulation (LL-HL at full load)
Load Regulation (25% to 100% FL)
Single
Dual
1%
5%
Cross Regulation (asymmetrical load 25%/100% FL)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
5%
75mVp-p
0.02%/ꢀCꢁ max.
500µS
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
5V
12V
15V
6.2V
15V
18V
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
Efficiency
150% typ
Hiccupꢁ automatic recovery
see „Selection Guide“ table
Isolation Voltage
1.600VDC min.
continued on next page
April-2005
www.recom-international.com
225
POWERLINE
RP15-S_DEW
Series
DC/DC-Converter
Specifications (typical at nominal input and 25ꢀC unless otherwise noted)
Isolation Resistance
109 Ω min.
Isolation Capacitance
300pF max.
Operating Frequency
270kHz typ.
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
-40ꢀC to +85ꢀC(with derating)
+100ꢀC
-55ꢀC to +105ꢀC
10ꢀC/Watt
Thermal Impedance
Natural convection
Natural convection with Heat Sink
8.24ꢀC/Watt
MIL-STD-810D
Thermal Shock
Vibration
10-55Hzꢁ 2Gꢁ 30 Min. along Xꢁ Y and Z
5% to 95% RH
Relative Humidity
Case Material
Base Material
Potting Material
Nickel-Coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
EN55022
EN55022
Level A
Level A
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Conducted Immunity
Weight
48g
50.8 x 40.6 x 10.2mm
2.041 x 106 Hours
Dimensions
MTBF (see note 2)
Notes :
1. The RP15 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under
no-load condition will not damage these devicesꢁ however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case l: 50% Stressꢁ Temperature at 40ꢀC (Ground fixed and controlled environment).
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control voltage is reference to negative input.
8. Heat-sink optionꢁ Thermal impedance is 8.24ºC/Watt for natural convection and the P/N is 7G-0011A.
9. See application notes for EMI-filtering.
226
April-2005
www.recom-international.com
POWERLINE
RP15-S_DEW
Series
DC/DC-Converter
Package Style and Pinning (mm)
3rd angle
projection
50.10
40.60
10.20
5.6
dia.
1.0
45.70
5
17.80
10.20
10.20
Pin Connections
12.70
17.80
Bottom View
Pin #
Single
+Vin
Dual
+Vin
-Vin
CTRL
+Vout
Com
6
1
2
1
2
4
5
6
7
8
5.10
15.20
-Vin
CTRL
No Pin
+Vout
-Vout
Trim
7
8
-Vout
Trim
4
Pin Pitch Tolerance 0.35 mm
External Output Trimming
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
Trim Up
Trim Down
7(7)
8(8)
8(8)
6(5)
R
R
D
U
April-2005
www.recom-international.com
227
相关型号: