700-FSM4UU23 [ROCKWELL]
Multi-Delay Relay, DPDT, Momentary, 48VDC (Coil), 0.05s Adj Min, 216000s Adj Max, AC Input, AC Output, DIN-Rail Mount,;型号: | 700-FSM4UU23 |
厂家: | ROCKWELL INTERNATIONAL CORPORATION. |
描述: | Multi-Delay Relay, DPDT, Momentary, 48VDC (Coil), 0.05s Adj Min, 216000s Adj Max, AC Input, AC Output, DIN-Rail Mount, 光电二极管 继电器 |
文件: | 总251页 (文件大小:15438K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical Data
Relay and Timer Specifications
Bulletin Number 700
Topic
Page
149
Topic
Page
2
NEMA Industrial Relays
700-P Industrial Relays
Summary of Changes
151
167
172
176
181
187
188
208
213
221
223
228
233
237
246
General Information
3
700S-P and 700S-PK — Heavy-Duty Safety Control Relays
700-N Industrial Relays
General Purpose Relays
9
700-HA General-purpose Relay
700-HB Square Base Relay
12
700-R Sealed Switch Relays
700-RTC — Solid-State Timing Relay
IEC Control Relays
22
700-HD Flange Mount Square Base Relay
700-HF Square Base Relay
28
32
700-CF Control Relay
700-HC Miniature Ice Cube Relay
700-HK Slim Line Relay
39
700S-CF Control Relays
44
700-K Miniature Control Relays
Solid-state Relays
700-HL Terminal Block Relay
700-HLF Terminal Block Timing Relay
700-HP Slim Line Relay
50
60
Solid-state Relay Glossary
700-SC Ice Cube Relays
64
700-HPS Safety Control Relay
700-HJ Magnetic Latching Relay
700-HG Power Relay
65
700-SF Square Base Relays
700-SH Hockey Puck Relays
700-SK Slim Line Relays
71
75
700-HHF Flange Mount Power Relay
700-HTA Alternating Relay
80
83
General Purpose Electronic Timers and Counters
700-FE Economy Timing Relay
700-FS High Performance Timing Relay
700-HNC Miniature Timing Relay
700-HNK Ultra-Slim Timing Relay
700-HR Dial Timing Relays
89
92
96
103
109
116
128
133
138
700-HT Plug-in Timing Relay
700-HV Timing Relay
700-HX Multi-Function Digital Timing Relay
Relay and Timer Specifications
Summary of Changes
This publication contains new and updated information as indicated in the following table.
Topic
Page
16
700-HA Relay - updated operating time descriptions
700-HC Relay - updated status indicator footnote
700-HC Relay - updated operating time description
700-HK Relay - updated status indicator footnote
700-HK Relay - updated operating time description
700-HLF Relay - updated operating time description
700-HP Relay - added jumper catalog numbers
700-HP Relay - added dimension drawings
700-HPF - updated catalog number explanation
700-HV- updated standards information
700-P - updated operating coils
39
42
44
46
61
65
69
117
135
157
177
205
700-R - updated accessories
700-CF - added Contact Rating Table from EN 60947-5-1
2
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
General Information
Contact Data Tables
AC and DC Switching Capability
NEMA
Pilot
Relay
Type
Contact
Contact
Contact
Material
20
mA
50
mA
100
mA
1 mA
1 A
3 A
5 A 10 A 20 A 25 A 30 A 35 A
Arrangement Style
Duty(1)
Up to 8 form X
or 8 form Y
A600
P600
700-CF
cross stamped Ag
24V
AC
DC
AC
Up to 8 form X
or 8 form Y
A600
P600
24
V
700S-CF
cross stamped Ag
DC
AC
DC
Up to 8 form X
or 8 form Y
A300
Q300
700-K
700-P
700-PK
700-PH
700-R
bifurcated
bifurcated
single
AgCu
NiAg
AgCdO
AgCdO
W
17V
A600
P600
Up to 12 form
X or 8 form Y
10V
AC
DC
2X A600
2X P600
(20 A Lighting
AC
Up to 12 form
X or 8 form Y
10V
Load)
DC
AC
Up to 6 form X
or 4 form Y
A600
P600
tandem
10V
(35 A Lighting
Load)
DC
B300
C600
P300
Up to 8 form A
or form B
AC
DC
sealed sw.
5V
5V
Up to 4 form A
or form B
B600
P300
AC
DC
700-RTC
700S-P
sealed sw.
bifurcated
W
A600
P600
Up to 12 form
X or 8 form Y
NiAg
10V
AC
(1) See NEMA Ratings and Test Values on page 5
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
3
Relay and Timer Specifications
Contact Data Tables
AC and DC Switching Capability
NEMA
Pilot
Duty
Relay
Type
Contact
Arrangement Style
Contact
Contact
Material
10
mA
50
mA
100
mA
1 mA
1 A
3 A
5 A
10 A 20 A 25 A 30 A 35 A
AC
DC
700-FE
700-FS
700-HA
1 N.O.
single
single
single
AgCdO
AgCdO
AgNi
D300
B300
B300
10V
(24V Max.)
AC
DC
1, 2 form C
2, 3 form C
10V
10V
(24V Max.)
AC
DC
(24V Max)
AC
DC
(24V Max)
700-HAX 2, 3 form C
bifurcated Au/AgNi B300
6V
AC
DC
(24VMax.)
700-HB
2, 3 form C
single
single
single
single
single
single
single
single
single
single
single
AgNi
Ag/Au
AgNi
B300
10V
AC
DC
C300
Q300
700-HC14 4 form C
700-HC22 2 form C
700-HC24 4 form C
10V
(30V Max.)
B300
Q300
AC
DC
10V
10V
AC
DC
(30V Max.)
C300
Q300
AgNi
AC
DC
(24V Max)
700-HD
700-HF
700-HG
2, 3 form C
AgCdO
AgCdO
AgNi
B300
B300
A600
A600
B600
B300
10V
10V
10V
10V
10V
AC
DC
(30V Max)
2, 3, 4 form C
AC
DC
(28V Max)
1 form X, 1 form
C, 2 form A, 2
form C
AC
DC
(28V Max)
700-
HHF45
1 form X
2 form C
3 form C
1, 2 form C
AgNi
AC
DC
700-
HHF62
AgNi
(28V Max)
AC
DC
(28V Max)
700-
HHF73
AgNi
10V
AC
DC
700-HJ
AgCdO
AgNi
—
10V
10V
(24V Max.)
AC
DC
700-HK36 1 form C
700-
1 form C
700-HK32 2 form C
700-
2 form C
single
single
single
single
B300
Au/AgNi B300
AgNi B300
Au/AgNi B300
(30V Max)
AC
DC
5V
(30V Max)
4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Contact Data Tables
AC and DC Switching Capability
1 A 3 A 5 A 10 A
NEMA
Pilot
Duty
10
mA
50
mA
100
mA
Contact
Contact Contact
1 mA
20 A 25 A 30 A 35 A
Relay Type
Arrangement Style
Material
Solid-State 1
N.O.
AC/
DC
700-HLS
700-HLT
—
—
—
3V
B300
R300
6
A
1 Form C
1 Form C
2 Form C
2 Form C
single
single
single
single
AgSnO
AgSnO
AgNi
12V
AC/DC
B300
R300
6
700-HLT_ _X
700-HP
8V
5V
AC/DC
AC/DC
AC/DC
A
B300
Q300
8
A
(300 mW)
AgNi +
Gold
B300
Q300
5V
(50 mW)
8
A
700-HPX
AC
DC
(30V
Max)
700-HS
700-HT
2 Form C
2 form C
single
single
AgCdO
AgNi
B300
B300
10V
AC
DC
(30V
Max)
10V
NEMA Ratings and Test Values
NEMA Ratings and Test Values for AC Control Circuit Contacts at 50 or 60 Hz
Maximum Current [A]
120V
Make
240V
Make
480V
Make
600V
VA
NEMA Contact Rating Thermal Continuous
Designation
Test Current [A]
Break
Break
Break
Make
Break
Make
Break
A150
A300
A600
B150
B300
B600
C150
10
10
10
5
60
6.00
6.00
6.00
3.00
3.00
3.00
1.50
1.50
1.50
0.60
0.60
0.30
12
—
30
—
—
—
15
—
—
—
12
—
—
7200
7200
7200
3600
3600
3600
1800
1800
1800
432
720
720
720
360
360
360
180
180
180
72
60
3.00
3.00
—
—
60
30
1.50
—
1.20
—
30
—
15
—
—
7.5
—
—
3.75
—
—
—
—
30
—
—
6
5
30
1.50
1.50
—
—
—
5
30
15
0.75
—
0.60
—
2.5
2.5
2.5
1.0
1.0
0.5
20
20
15
—
7.5
7.5
—
1.8
—
60
—
—
3
C300
15
0.75
0.75
—
—
—
C600
15
0.375
—
0.30
—
D150
D300
D600
2X A300
2X A600
3.60
3.60
1.80
120
120
—
—
—
—
24
0.30
—
—
—
432
72
—
—
216
36
6.00
6.00
—
—
14400
14400
1440
1440
12
60
3.00
2.40
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
5
Relay and Timer Specifications
NEMA Ratings and Test Values for DC Control Circuit Contacts
Maximum Current [A]
Make or Break at 300V or less
[VA]
NEMA Contact Rating Designation
Thermal Continuous Test Current [A]
5…28V
125V
250V
301…600V
N150
N300
N600
P150
P300
P600
Q300
Q600
2X P600
10
10
2.2
2.2
2.2
1.1
1.1
1.1
0.55
0.55
2.2
—
—
275
275
275
138
138
138
69
10
10
1.1
—
10
10
1.1
0.40
—
5.0
5.0
5.0
2.5
2.5
10
5.0
5.0
5.0
2.5
2.5
10
—
0.55
0.55
0.27
0.27
1.1
—
0.20
0.11
0.11
0.40
69
275
NEMA Definitions for Contact Arrangements
Contact
Arrangement
Description
Diagram
A Form A contact arrangement is one that has single-pole, single-throw, normally open contacts. The function of this
arrangement is to close a circuit when actuated.
Form A
Form B
Form C
Form X
Form Y
Form Z
A Form B contact arrangement is one that has single-pole, single-throw, normally closed contacts. The function of this
arrangement is to open a circuit when actuated.
A Form C contact arrangement is one that has single-pole, double-throw contacts with three terminals - one for normally
open, one for normally closed, and one common. The function of this arrangement is to transfer a circuit when actuated.
A Form X contact arrangement is one that has single-pole, single-throw, normally open double-make contacts. The function
of this arrangement is to close a circuit when actuated.
or
or
A Form Y contact arrangement is one that has single-pole single-throw normally closed double-break contacts. The function
of this arrangement is to open a circuit when actuated.
A Form Z contact arrangement is one that has single-pole, double-throw, contacts with four terminals — two for normally
open and two for normally closed. The function of this arrangement is to open one circuit and close the other.
6
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Timing Relay Selection Criteria
Single Function Timers: Timers that have only 1 timing mode (for example, ON-Delay or OFF-Delay).
Multi-Function Timers: Timers that have 4…8 timing modes that are selected by turning the mode selection switch.
RESET
POWER
ON
OFF
ON-Delay or (Delay on Operate)
When power is applied continuously (or when power and a start signal are applied), the
timing cycle begins. The output contacts change state after the time delay is completed.
The contacts will return to their normal state when a reset signal is applied or power is
removed.
START SIGNAL
ON
OFF
OUTPUT CHANGED STATE
NORMAL STATE
TIME DELAY
RESET
RESET
RESET
POWER
ON
OFF
OFF-Delay or (Delay on Release)
START SIGNAL
ON
OFF
Power is applied continuously. When a start signal is applied, the output contacts change
state immediately. When the start signal is removed, the timing cycle begins. The output
contacts will return to their normal state once the time delay is completed. Reset will
occur when a reset signal is applied or power is removed.
OUTPUT CHANGED STATE
NORMAL STATE
TIME DELAY
POWER
ON
OFF
One Shot or (Repeat Cycle)
START SIGNAL
ON
OFF
Power is applied continuously. When a start signal is applied, the output contacts change
state immediately and the timing cycle begins. The output contacts will return to their
normal state once the time delay is completed. Reset will occur when a reset signal is
applied or power is removed.
OUTPUT CHANGED STATE
NORMAL STATE
TIME DELAY
POWER
ON
OFF
Repeat Cycle or (Flicker)
START SIGNAL
ON
OFF
Power is applied continuously. When a start signal is applied, the timing cycle begins.
When the time delay is completed, the output contacts change state and the next timing
cycle begins. This cycle will repeat until a reset signal is applied or power is removed.
OUTPUT CHANGED STATE
NORMAL STATE
OFF
TIME
ON
TIME
OFF
TIME
ON
TIME
OFF
TIME
Flexibility
Mounting — Timing relays are available in several different models. They can be plugged into the same socket as the relay, or use a separate plug-in
socket mounting.
Contacts — The contacts are of various types and ratings. See the appropriate specification pages for more details.
Functionality — Timing relays with multi-range and multi-function capability are available. Allowing you to stock one relay to cover a wide variety
of applications.
External Trigger Switch — OFF-Delay, One-Shot, and other timer functions require an external trigger switch (from a relay or push button) to
control the timing function. The external trigger switch will cause the timing function to start. In OFF-Delay, the trigger switch closes to energize
the output and when the trigger switch opens the OFF-Delay starts to time out. At the end of the time delay, the output is de-energized and the
output contacts return to their shelf state
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
7
Relay and Timer Specifications
Surge Suppression Information
Max.
Max.
Relay
Contact
Dropout
Time
Transient
Voltage
Relative to
System
Suppression
Technique
Photo
Cat. No.
For use with
Voltage
700-ADR
700-HA, -HB,-HK, -HP (6…220V DC)
700-HC (6…24V DC)
Diode
3X
—
—
—
—
—
—
—
3
700-ADL1
700-ADL1R
700-ADL2
700-ADL2R
700-ADL3
700-ADL3R
700-AR1
Diode + LED
Diode + LED
Diode + LED
Diode + LED
Diode + LED
Diode + LED
RC
3X
700-HB, -HA, -HK, -HP (6…24V DC)
700-HC (28…60V DC)
3X
3X
700-HB, -HA, -HK, -HP (28…60V DC)
700-HC (110…220V DC)
3X
3X
700-HB, -HA, -HK, -HP (110…220V DC)
700-HB, -HA, -HC,-HK, -HP (6…24V AC/DC)
700-HB,-HA, -HC,-HK, -HP (110…240V AC/DC)
700-HB,-HA, -HC,-HK, -HP (6…24V AC)
700-HB, -HA, -HC, -HK, -HP (110…240V AC)
—
3X
No Effect
No Effect
No Effect
No Effect
—
700-AR2
RC
—
—
—
6…10X
3X
700-AV1R
700-AV3R
700-CF built-in
100-FSC
Varistor + LED
Varistor + LED
Diode
700-CF Relay
100C, 700-CF
R-C Ckt
No Effect
No Effect
100-FSV
100C, 700-CF
MOV
—
100-FSD
100C, 700-CF
100C, 700-CF
Diode
Diode
70…95 ms 6…10X
100-JE
5X
6…10X
700-N5
700-P, 700-N
700-P, 700-N
RC
RC
No effect
No effect
3X
3X
700-N24
700-R Relay
700-R built-in
—
Diode
RC
—
6…10X
3X
199-FSMA1, FSMA2
199-FSMA9, 10, 11
700-P, 700-H, 700-CF, 700DC-R
700-P, 700-H, 700-CF, 700DC-R
No effect
No effect
MOV
—
199-FSMZ
700-P, 700-H, 700-CF, 700DC-R
Diode
5X
—
8
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
General Purpose Relays
Product Overview
Bulletin No.
700-HA
General-purpose Relay
700-HB
700-HD
700-HF
Type
General-purpose Relay
General-purpose Relay
General-purpose Relay
• Pin-style terminals
• Blade-style quick connect terminals
• Standard ON/OFF flag indicator
• Electrical schematic on face
• Standard ON/OFF flag indicator
• Electrical schematic on face
• Clear cover for visual inspection
• Square-base
• Flange-mounted
• Blade-style quick connect terminals
• Plug-in quick connect solder terminals
• Optional push-to-test
• Optional LED
Features
• Clear cover for visual inspection
• Optional push-to-test and manual • Optional push-to-test and manual • Clear cover for visual inspection
override
• Optional LED
override
• Optional LED
Contact Ratings
Contact Form
DPDT, 3PDT
Single
DPDT, 3PDT
Single
DPDT, 3PDT
Single
DPDT, 4 PDT
Single
Contact Type
Contact Material
AgNi, AgNi + Gold
AgCdO
AgCdO
AgCdO
Operating Current,
Under Resistant Load,
Max
700-HA: 10 A
700-HAX: 6 A
15 A
15 A
10 A
700-HA: 10V, 5 mA
700-HAX: 6V 1 mA
Permissible Load, min
Coil Ratings
10V, 10 mA
10V, 10 mA
5V, 100 mA
AC: 6, 12, 24, 48, 110, 120, 230, 240,
277V
DC: 6, 12, 24, 36, 48, 60, 80, 110, 125, DC: 6, 12, 24, 48, 110V
140, 220V
AC: 6, 12, 24, 120, 240V
AC: 6, 12, 24, 120, 208, 240V
DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
Coil Voltage
80…110% of nom voltage at 50 Hz
80…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz
85…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
Permissible Coil Voltage
Variation
Electrical Ratings
Pole-to-pole: 2000V
Contact-to-coil: 2000V
Contact-to-frame: 2000V
Pole-to-pole: 2500V
Contact-to-coil: 4000V
Contact-to-frame: 2500V
Pole-to-pole: 2500V
Contact-to-coil: 4000V
Contact-to-frame: 2500V
Pole-to-pole: 1500V
Contact-to-coil: 1500V
Contact-to-frame: 1500V
Dielectric Withstand
Voltage
200,000 min
500,000 min (DPDT)
Electrical Service Life
(Cycles)
100,000 min
100,000 min
100,000 min
Reference
Certifications
CE, cULus, cURus, CSA, Lloyds
CE, cULus, cURus, CSA, Lloyds
700-HN153, 700-HN154
22
CE, UR, CSA, Lloyds
CE, UR, CSA
700-HN100, 700-HN101, 700-HN125,
700-HN126, 700-HN204, 700-HN205
Socket Catalog Numbers
Page
—
28
700-HN262, 700-HN264
32
12
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
9
Relay and Timer Specifications
Bulletin Number 700-HC
700-HK
700-HL
700-HP
Type
Interposing/Isolation Relay
Interposing/Isolation Relay
Interposing/Isolation Relay
Interposing/Isolation Relay
•
•
•
•
•
Blade-style terminals
•
•
•
•
•
•
•
Ideal for PLC Interfaces
Built-in Coil Surge Protection
Fully Assembled Relay/Sockets
Standard LED
Relay or Solid-state Output
Optional: Leakage Current
Suppression Solution
Standard ON/OFF flag indicator
Electrical schematic on face
Clear cover for visual inspection
Optional push-to-test and
manual override
•
•
•
•
Optional pilot light
Retainer clip (comes with socket)
Low switching capacity
•
•
PCB “Pin Style” mounting
5 mm pin spacing
Features
Push-to-test and manual override
•
Optional LED
Contact Ratings
Contact Form
Contact Type
DPDT,4PDT
Single
SPDT,DPDT
Single
SPDT 1 N.O. (SSR)
Single
DPDT
Single
Contact Material
AgNi, AgNi + Gold
AgNi, AgNi + Gold
AgSnO
AgNi, AgNi + Gold
Operating Current,
Under Resistant
Load, Max
10 A (DPDT)
7 A (4PDT)
6 A (SPDT), 2 A (SSR DC output),
2 A (SSR AC output)
8 A (DPDT), 16 A (SPDT)
8 A
10V, 10 mA (Gold),5V, 10 mA or
25V, 2 mA (Silver)
12V 6 mA (72 mW) Silver
8V, 2.5 mA (20 mW)Gold
5V 5 mA (50 mW) Gold,
5V 5 mA (300 mW) Silver
Permissible Load,
min
5V 60 mA (Silver), 5V 10 mA (Gold)
Coil Ratings
Coil Voltage
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
AC: 12, 24, 48, 110, 120, 230, 240V
DC: 12, 24, 48, 125, 230, 240V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 50 Hz 85…110% of nom voltage at 50 Hz 80…110% of nom voltage at 50 Hz
80…110% of nom voltage at 60 Hz 80…110% of nom voltage at 60 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at 60 Hz
Permissible Coil
Voltage Variation
80…110% of nom voltage at DC
73…110% of nom voltage at DC
80…110% of nom voltage at DC
73…150% of nom voltage at DC
Electrical Ratings
Pole-to-pole: 1000V
Contact-to-coil: 2000V
Contact-to-frame: 2000V
Pole-to-pole: 1500V
Contact-to-coil: 1500V
Contact-to-frame: 1500V
Pole-to-pole: 1000V
Contact-to-coil: 4000V
Contact-to-frame: 1500V
Pole-to-pole: 2000V
Contact-to-coil: 5000V
Dielectric
Withstand Voltage
Electrical Service
Life (Cycles)
100,000 min
100,000 min
100,000 min
100,000 min
Reference
Certifications
CE, cULus, cURus, CSA, Lloyds
700-HN103, 700-HN128, 700-HN104
39
CE, UL, UR, CSA
CE, cURus, cULus, ABS
CE, cULus, cURus, CSA, Lloyds
700-HN123, 700-HN230
64
700-HN121, 700-HN221, 700-HN122,
700-HN222, 700-HN223, 700-HN224
Socket Catalog
Numbers
—
50
Page Number
44
10
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Bulletin Number 700-HJ
700-HG
700-HHF
Type
Magnetic Latching Relay
Power Relay
Power Relay
•
•
Panel mount with screw terminals
Optional magnetic blowouts for switching DC
loads
•
•
Socket mounted
Ideal for lighting applications
•
•
Flange mounted
Optional LED
Features
•
Optional snap action switch
Contact Ratings
Contact Form
Contact Type
SPDT,DPDT(Singleor Dual Coil)
SPST-N.O.-DM, SPDT, DPST-N.O., DPDT
SPST-NO-DM, DPDT,3PDT
Single
AgCdO
Single
AgNi
Single
AgNi
Contact Material
Operating Current,
Under Resistant
Load, Max
10
A
40
A
20 A (3PDT), 25 A (DPDT), 30 A (SPDT)
10V 50 mA
10V 100 mA (3PDT)
Permissible Load,
min
10V 50 mA
10V 50 mA
Coil Ratings
Coil Voltage
AC: 24V, 120V, 240V
DC: 12V, 24V
AC: 24V, 120V, 240V, 277V, 480V
DC: 12V, 24V, 48V, 110V, 220V, 250V
AC: 24V, 120V, 240V
DC: 6V,12V,24V
85…110% of nom voltage at 50 Hz
85…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz
85…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
85…110% of nom voltage at 50 Hz
85…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
Permissible Coil
Voltage Variation
Electrical Ratings
Pole-to-pole: 1500V AC Contact-to-coil: 1500V
AC Contact-to-frame: 1500V AC
Pole-to-pole: 2200V AC Contact-to-coil: 2200V
AC Contact-to-frame: 2200V AC
Pole-to-pole: 2200V AC Contact-to-coil: 2200V
AC Contact-to-frame: 2200V AC
Dielectric
Withstand Voltage
Electrical Service
Life (Cycles)
100,000 minimum
100,000 minimum
100,000 minimum
Reference
Certifications
CE, UR, CSA
CE, UL, CSA
CE, UR, CSA
Socket Catalog
Numbers
700-HN153, 700-HN154
71
—
75
—
80
Page Number
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
11
Relay and Timer Specifications
700-HA General-purpose Relay
•
•
•
•
•
10 A contact rating
DPDT, 3PDT
Pin-style terminals
Standard ON/OFF flag indicator
Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or
multi-function timer
•
Contact choices: standard silver nickel, or bifurcated silver nickel with gold plating
(1)
Tube Base Relay with PIN Terminals (Single Contact) — Mechanical ON/OFF Indicator Included
Wiring Diagrams
Description
Contact Rating
Coil Voltage
Cat. No.(1)
U.S./Canada
International
6V AC
12V AC
24V AC
120V AC
240V AC
277V AC
6V DC
12V DC
24V DC
36V DC
48V DC
60V DC
80V DC
110V DC
125V DC
140V DC
220V DC
6V AC
12V AC
24V AC
120V AC
240V AC
6V DC
12V DC
24V DC
48V DC
60V DC
80V DC
110V DC
125V DC
140V DC
220V DC
700-HA32A06
700-HA32A12
700-HA32A24
700-HA32A1
700-HA32A2
700-HA32A27
700-HA32Z06
700-HA32Z12
700-HA32Z24
700-HA32Z36
700-HA32Z48
700-HA32Z60
700-HA32Z80
700-HA32Z1
700-HA32Z01
700-HA32Z3
700-HA32Z2
700-HA33A06
700-HA33A12
700-HA33A24
700-HA33A1
700-HA33A2
700-HA33Z06
700-HA33Z12
700-HA33Z24
700-HA33Z48
700-HA33Z60
700-HA33Z80
700-HA33Z1
700-HA33Z01
700-HA33Z3
700-HA33Z2
DPDT
2-pole
2 Form C
10 A
Single AgNi Contact
B300
700-HN100
Sockets
700-HN125
700-HN204
3PDT
3-pole
3 Form C
10 A
B300
Single AgNi Contact
700-HN101
700-HN205
Sockets
700-HN126
(1) LED Option: Add suffix (-4) to the selected 700-HA Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HA Relay Cat. No., except for the 240V
AC units, add (-3-4L). Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HA relay.
LED not available for 220V DC and 277V AC coils.
(1) For Time Modules and Surge Suppressor Modules, see Accessories.
12
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Tube Base Relay with PIN Terminals (Bifurcated Contacts with Gold Overlay) — Mechanical ON/OFF Indicator Included
Wiring Diagrams
U.S./Canada
Description
Contact Rating
Coil Voltage
Cat. No
International
6V AC
700-HAX2A06
700-HAX2A12
700-HAX2A24
700-HAX2A1
700-HAX2A2
700-HAX2A27Δ
700-HAX2Z06
700-HAX2Z12
700-HAX2Z24
700-HAX2Z36
700-HAX2Z48
700-HAX2Z1
700-HAX2Z01
700-HAX2Z3
700-HAX3A06
700-HAX3A12
700-HAX3A24
700-HAX3A1
700-HAX3A2
700-HAX3Z06
700-HAX3Z12
700-HAX3Z24
700-HAX3Z48
700-HAX3Z1
700-HAX3Z01
700-HAX3Z3
12V AC
24V AC
120V AC
240V AC
277V AC
6V DC
DPDT
2-Pole
2 Form C
Bifurcated AgNi Contacts with Gold Plating
6 A
12V DC
24V DC
36V DC
48V DC
110V DC
125V DC
140V DC
6V AC
700-HN100
700-HN204
Sockets
700-HN125
12V AC
24V AC
120V AC
240V AC
6V DC
3PDT
3-Pole
3 Form C
Bifurcated AgNi Contacts with Gold Plating
6 A
12V DC
24V DC
48V DC
110V DC
125V DC
140V DC
700-HN101
700-HN205
Sockets
700-HN126
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
13
Relay and Timer Specifications
Accessories - 700-HA Relays
Pkg.
Qty.
Photo
Description
Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Timing Relays, -HT (On-Delay), and -HRM, -HRC
and -HV (Repeat Cycle) Timing Relays.
10
10
700-HN100
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for
use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC, and -HV (Repeat Cycle) Timing Relays. No
retainer clip required.
700-HN125
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal
10
10
700-HN101
700-HN126
Construction. 11-pin for use with 3PDT 700-HA relays.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style Terminal
Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.
8-Pin Socket — Can Be Used With or Without Timing Attachment or Surge Suppressor
Screw Terminal Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction. Used with
DPDT 700-HA Relays.
10
10
700-HN204
700-HN205
11-Pin Socket — Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal
Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction.
Used with 3PDT 700-HA relays.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Photo
Description
Pkg. Qty. Cat. No.
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket
10
700-ADR
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10
700-ADL1R
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205
10
700-ADL2R
700-ADL3R
700-AV1R
700-AV3R
socket
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205
socket
10
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205
socket
10
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205
socket
10
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket
10
10
700-AR1
700-AR2
14
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Photo
Description
Pkg. Qty. Cat. No.
Timing Module
On-Delay or One-Shot selectable voltage range:
12…24V AC/DC used with sockets that accept plug-in
accessory modules.
1
1
1
700-AT3
On-Delay
U (A1/A2)
LED & R
Timing Module
t
On-Delay or One-Shot selectable voltage range:
110…125V AC used with sockets that accept plug-in
accessory modules.
700-AT3A1
700-AT3A2
One-Shot
U (A1/A2)
LED & R
Timing Module
t
On-Delay or One-Shot selectable voltage range:
230…240V AC used with sockets that accept plug-in
accessory modules.
1. 1 s
0.05…1 s
2. 10 s
0.5…10 s
5…100 s
3. 100 s
4. 10 min
5. 100 min
6. 10 hours
0.5…10 min
5…100 min
0.5…10 h
5…100 h
1
700-HT3
7. 100 hours
8. LED Indicator
Socket and Retainer Clip Reference
Relay Type
Socket
Retainer Clip
700-HN100
700-HN125
700-HN204
700-HN157
Not Required
700-HN157
700-HA32
700-HAX2
700-HN101
700-HN126
700-HN205
700-HN157
Not Required
700-HN157
700-HA33
700-HAX3
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
15
Relay and Timer Specifications
Specifications - 700-HA Relays
Attribute
700-HA
ElectricalRatings
Pilot Duty Rating (1)
NEMA B300
RatedThermal Current (I
)
HA = 10 A – 120V, 240V; HAX = 6 A – 120V, 240V
th
Rated Insulation Voltage (Ui)
250V IEC – 300V UL/CSA
Break
Make
Hp
Inductive
120VAC
30 A
15 A
3 A
1.5 A
1/3
1
Contacts
240VAC
General-purpose
Resistive
10 A, 240V AC
10 A, 30V DC
Min. Low Energy Permissible Load
Permissible Coil Voltage Variation
HA = 10V, 5 mA HAX = 5V, 2 mA
Pickup: 80…110% of nom voltage at 50 Hz, 80…110% of nom voltage at 60 Hz, 80…110% of nom voltage at DC
AC Coils
Inrush
Sealed
DC Coils
50 Hz
3.3VA
2.2VA
60 Hz
2.85VA
1.9VA
CoilConsumption 10ꢀ
1.3 W
Must Dropout Voltage
20% of nom V AC; 10% of nom V DC
50 MΩ (700-HA), 30 MΩ (700-HAX)
Max. Contact Resistance
Design Specification/TestRequirements
Electrical
Pole-to-Pole
2000V
2000V
Contact to Coil
ElectricalLife(Operating)
100,000 min.
Mechanical
Degree of Protection (Open Type) IEC 529
Mechanical Lifecycles (AC/DC)
Switching Frequency Operations
Coil Voltages
IP 40
> 20 x 106/ 50 x 10
6
3600/HR
See Product Selection
Pickup
12 ms
12 ms
4 Ops/s
5 G
Operating Time
Dropout
Maximum Operating Rate
Vibration
Endurance
Operational
Endurance
Operational
2.5 G
50 G
Shock
9 G
Environmental
Construction
Operating
Storage
AC/DC
AC/DC
–40…+70 °C (–40…+158 °F)
–40…+100 °C (–40…+212 °F)
Temperature
Altitude
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High-Dielectric Material
Transparent Dust Cover
700-HA:
10 A – AgNi
6 A – Bifurcated/Gold Plating AgNi
In accordance with EN50 0005
Contact Material
700-HAX:
Terminal Markings on Socket
Sockets
8-Pin Socket — 700-HN100, -HN125, -HN204, 11-Pin Socket — 700-HN101, -HN126, -HN205
cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted (File No. E3125, Guide
NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473)
Certifications
Standards
UL508, CSA C22.2 No. 14, EN 61810-1
(1) See NEMA Ratings and Test Values on page 5
16
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Relay Performance Graphs
Load (kVA)
Voltage DC (V)
COS φ
Contact life vs. AC1 load at 1,800 cycles/h
Breaking capacity for DC1 load at 1,800 cycles/h
Load reduction factor vs. cos φ
A = load applied to one contact
B = load applied to two contacts in series
C = load applied to three contacts in series
Specifications - 700-HT3 Time Module
Attribute
700-HT3
ElectricalRatings
Operating Voltage Range
Power Consumption
12…240V AC (50/60 Hz) 12…240V DC
0.1 W(12V)
1.0 W(230V)
Mechanical
Degree of Protection of Input (B1) Terminal
Input Terminal Wire Range
IP 20 (Guarded Terminal)
2
2
2
2
1.0 x 0.2 mm …2.5 mm (24 …14 AWG)
2.0 x 0.2 mm …1.5 mm (24…16 AWG)
Input Terminal Torque Range
Status Indicator
0.45…0.8 N•m (4…7 lb•in)
Red
1%
Repeat Accuracy (1)
RecoveryTime
<50 ms
Three DIP switches, seven ranges (set from 5…100% of range):
1 s, 10 s, 100 s, 10 min, 100 min, 10 h, 100 h
Selectable Timing Ranges
Selectable Timing Modes
Three DIP switches, eight modes:
1. PowerOn–Delay
5. Signal Off-Delay
6. Signal On-One-Shot
2. Power On One-Shot
3. Power On Repeat Cycle, On Start
4. Signal On-Delay and Signal Off-Delay
7. Signal Off-One-Shot
8. Signal On and Signal Off Watchdog Monitor
Adjustable Trimmer Scale Accuracy
Environmental
5% of Time Range
Operating
–20…+50 °C (–4 …+122 °F)
–55…+85 °C (–67…+185 °F)
2000 m (6560 ft)
Temperature
Storage
Altitude
Construction
Enclosure
Gray Plastic Housing
Mounting with Socket Only
Sockets
8- or 11-Pin Socket with Module Plug
700-HN204 (8-Pin with Plug), 700-HN205 (11-Pin with Plug)
Certifications
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CE Marked
UL508, CSA C22.2 No. 14, EN 61810-1
Standards
(1) At constant voltage and temperature.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
17
Relay and Timer Specifications
Timing Charts - 700-HT3 Multi-function Time Module (t = Time Range 0.05 s…100 h)
Terms:
U is Power Input
R is Relay Output
S Signal, +A1 Socket, B1 Timer
t is the resulting Time Delay (Red light-emitting diode)
1. Power On-delay
3. Power On Repeat Cycle, On Start
Apply power (U) to timer. Relay contacts (R) change state after time delay (t) is complete.
Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay (t)
begins. When the time delay is complete, the contacts return to their shelf state for time delay (t)
(time on = time-off). This cycle repeats until the power is removed. Terminal B1 is not used in this
mode.
Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.
2. Power On One-shot
4. Signal On-delay and Signal Off-delay
Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay begins.
When the time delay (t) is complete, contacts return to their shelf state. Contacts return to their
shelf state when power is removed. Terminal B1 is not used in this mode.
Apply power (U) to timer. When the signal (S) is closed the time delay (t) begins, after the time
delay is completed the relay contacts (R) change state. Opening the signal starts the time delay,
after the time delay is completed the contacts return to their shelf state. If the signal is closed or
opened before the time delay is complete, the time delay is reset. Contacts return to their shelf
state when power is removed.
Timing Charts -Cat. No. 700-HT3 Timing Modes, Time Description, Timing Charts, and DIP Switch Selections
Terms:
U is Power Input
R is Relay Output
S Signal, +A1 Socket, B1 Timer
t is the resulting Time Delay (Red light-emitting diode)
5. Signal Off-delay
7. Signal Off One-shot
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state
immediately. When the signal is opened, the time delay (t) begins. If the signal is closed before
the time delay is complete, the time delay is reset and the relay remains energized. When the
time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state
when power is removed.
Apply power (U) to timer. When the signal (S) is closed and then opened, the relay contacts (R)
change state immediately and the time delay (t) begins. After the time delay begins, opening or
closing the signal will not reset the time delay. When the time delay is complete, the contacts
return to their shelf state. Contacts return to their shelf state when power is removed.
8. Signal On and Signal Off Watchdog Monitor
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) energize
immediately and the time delay (t) begins. If the signal is opened before the time delay is
complete, the relay remains energized and the time delay is reset. When the time delay is
completed, the contacts return to their shelf state. If the signal is opened after the time delay is
complete, the relay contacts energize immediately and the same time delay begins. Continuous
cycling of the signal at a rate that is faster than the time delay causes the relay contacts to remain
energized. Contacts return to their shelf state when power is removed.
6. Signal On One-shot
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state
immediately and the time delay (t) begins. After the time delay begins, opening or closing the
signal will not reset the time delay. When the time delay is complete, the contacts return to their
shelf state. Contacts return to their shelf state when power is removed.
18
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions -700-HA Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
54.1
(2-1/8)
32.8
(1-3/10)
36.5
(1-9/20)
700-HA Relay
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(39-3/8)
(0.3)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
A
B
C
D
Approx. Shipping Wt.
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
1.85 kg
(4.07lb)(10/pkg)
199-DR1
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
3.68 kg
(8 lb) (5/pkg)
199-DR4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
19
Relay and Timer Specifications
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
24.6
(31/32)
40.1
(1-37/64)
20.8
(53/64)
30.0
(1-3/16)
26
(1-1/32)
24.9
(63/64)
54.9
(2-5/32)
65.0
(2-35/64)
51.1
(2-1/64)
4.2
(5/32)
38.0
(1-1/2)
33.0
(1-19/64)
#4–40
M3
14.7
(37/64)
Cat. No. 700-HN100
Panel Mounting
Cat. No. 700-HN125
2
2
Wire Size: 2 x 2.5 mm
Wire Size: 2 x 2.5 mm
Single Wire – Up to 12 AWG
Single Wire – Up to #12 AWG
2
2
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)
(Either Solid or Stranded)
Double Wire – 2 x 2.5 mm (#2-14 AWG… #2-20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
26
(1-1/32)
30
(1-3/16)
65.0
(2-35/64)
38.0
(1-1/2)
#4-40
M3
Cat. No. 700-HN101
Panel Mounting
Cat. No. 700-HN126
2
2
Wire Size: 2 x 2.5 mm
Wire Size: 2 x 2.5 mm
Single Wire – Up to #12 AWG
2
Single Wire – Up to #12 AWG
2
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)
(Either Solid or Stranded)
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
20
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
33.5
(1.32)
33.5
(1.32)
26.9
(1.06)
26.9
(1.06)
11.0 (0.43)
11.0
(0.43)
20.4
(0.80)
20.4
(0.80)
77.5
(3.05)
3.2
(0.13)
77.5
(3.05)
49.7
(1.96)
49.7
(1.96)
3.2 (0.13)
35.5
(1.40)
35.5
(1.40)
21.6
(0.85)
21.6
(0.85)
16.8
(0.66)
16.8
(0.66)
38.0
(1.50)
38.0
(1.50)
4.0 (0.16)
4.0 (0.16)
Cat. No. 700-HN204
Cat. No. 700-HN205
2
2
Wire Size: 2 x 2.5 mm
Wire Size: 2 x 2.5 mm
Single Wire – Up to #12 AWG
Single Wire – Up to #12 AWG
2
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires
(Either Solid or Stranded)
Double Wire – 2 x 2.5 mm (14 AWG …20 AWG) Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
38.0
(1.50)
54
(2.13)
6.3
(0.25)
10.5
(0.41)
Cat. No. 700-HT3
2
Wire Size: 2 x 1.5 mm (#2 – 16 AWG…#1–20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
21
Relay and Timer Specifications
700-HB Square Base Relay
•
•
•
•
•
15 A contact rating
DPDT, 3PDT
Blade-style quick connect /solder terminals (Faston 187 - 4.8 x 0.5 mm)
Standard ON/OFF flag indicator
Options: LED, push-to-rest, and manual override
Wiring Diagrams
U.S./Canada
Coil
Voltage
Photo
Description
Contact Rating
Cat. No.(1)
International
6V AC
700-HB32A06
700-HB32A12
700-HB32A24
700-HB32A1
700-HB32A2
700-HB32Z06
700-HB32Z12
700-HB32Z24
12V AC
24V AC
120V AC
240V AC
6V DC
32
DPDT
34
31
2-Pole
15 A
B300
2 Form C
Single AgCdO Contact
12V DC
24V DC
Input
48V DC
700-HB32Z48
Sockets
700-HN154
700-HN153
110V DC
6V AC
700-HB32Z1
700-HB33A06
700-HB33A12
700-HB33A24
700-HB33A1
700-HB33A2
700-HB33Z06
700-HB33Z12
700-HB33Z24
12V AC
24V AC
120V AC
240V AC
6V DC
3PDT
3-Pole
15 A
B300
3 Form C
Single AgCdO Contact
12V DC
24V DC
Input
48V DC
700-HB33Z48
700-HB33Z1
Sockets
700-HN154
700-HN153
110V DC
(1) LED Option: Add suffix (-4) to the selected 700-HB Relay Cat. No., except for the 240V AC Units, add (-4L).
Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HB Relay Cat. No., except for the 240V AC units, add (-3-4L)
Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HB relay.
22
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories - 700-HB Relays
Photo
Description
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket
Pkg. Qty. Cat. No.
10
700-ADR
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10
700-ADL1R
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205
10
700-ADL2R
700-ADL3R
700-AV1R
700-AV3R
socket
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205
socket
10
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205
socket
10
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205
socket
10
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket
10
10
700-AR1
700-AR2
Timing Module
On-Delay
On-Delay or One-Shot selectable voltage range:
1
1
1
700-AT3
U (A1/A2)
12…24V AC/DC used with sockets that accept plug-in
t
accessory modules.
LED & R
Timing Module
One-Shot
On-Delay or One-Shot selectable voltage range:
700-AT3A1
700-AT3A2
110…125V AC used with sockets that accept plug-in
U (A1/A2)
t
accessory modules.
LED & R
Timing Module
On-Delay or One-Shot selectable voltage range:
230…240V AC used with sockets that accept plug-in
accessory modules.
1. 1 s
0.05 s…1 s
0.5 s…10 s
5 s…100 s
2. 10 s
3. 100 s
4. 10 min
5. 100 min
6. 10 hours
0.5 min…10
min
1
700-HT3
5 min…100 min
0.5 h…10 h
7. 100 hours
5 h…100 h
8. LED Indicator
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
23
Relay and Timer Specifications
Photo
Description
Pkg. Qty.
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting. Guarded Terminal Construction
11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the
ability to use optional plug-in modules (700-A__ accessories, LED, surge suppression, timing modules).
10
700-HN153
Screw Terminal Base Socket — Panel or DIN Rail Mounting. Open Style Construction
10
10
700-HN154
199-DR1
11-blade for use with 700-HB relays.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
Retainer Clip
For Cat. Nos. 700-HN154 Sockets with 700-HB Relays
Secures relay in socket. Order must be for 10 clips or multiples of 10.
10
10
700-HN156
700-HN158
Retainer Clip
For Cat. Nos. 700-HN153 Sockets with 700-HB Relays
Secures relay in socket. Order must be for 10 clips or multiples of 10.
1492-MS5X12
1492-MS6X9
1492-MS6X12
1492-MS8X9
1492-MS8X12
1492-MP-Blank
Relay Identification Snap-in Markers
Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot 100
on top of product covers.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are
peel-off with sticky backing for easy placement on relays.
10
700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10
relays.
700-N41
Socket and Retainer Clip Reference
Relay Type
Socket Cat. No.
Retainer Clip Cat. No.
700-HN153
700-HN154
700-HN158
700-HN156
700-HB
24
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HB Relays
Attribute
700-HB
ElectricalRatings
Pilot Duty Rating (1)
NEMA B300
RatedThermal Current (I
)
15 A – 120V, 240V
250V IEC-300V UL/CSA
th
Rated Insulation Voltage (U )
i
Make
Break
Hp
Inductive
2 -Pole
60 A
3 -Pole
30 A
2 -Pole
6 A
3 -Pole
3 A
Contacts
120VAC
3/4
2
240VAC
30 A
15 A
3 A
1.5 A
General-purpose
Resistive
15 A, 240V AC
15 A, 30V DC
1000 mW (10V, 10 mA)
Min. Low Energy Permissible Load
Permissible Coil Voltage Variation
AC Coils
80…110% of Nominal Voltage at 50 Hz
80…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
50 Hz
3.3VA
2.2VA
60 Hz
2.85VA
1.9VA
Inrush
Sealed
DC Coils
Coil Consumption
10%
1.3 W
25%of VA
10% of W
50 MΩ
Max. Allowable Leakage
Max. Contact Resistance
Design Specification/TestRequirements
Mechanical
Dielectric Withstand Voltage
Pole-to-Pole
2500V
4000V
Contact to Coil
Degree of Protection (Open Type) IEC 529
Mechanical lifecycles (AC/DC)
Switching Frequency Operations
Coil Voltages
IP 40
6
6
> 10 x 10 /30 x 10
3600/HR
See Overview/Product Selection
Pickup
Operating Time (ms)
Dropout
20 ms
4 ms
4 Ops/s
5 G
Maximum Operating Rate
Endurance
Vibration
Operational
1.5 G
50 G
Endurance
Shock
Operational
15 G
Environmental
Construction
Operating
AC/DC
AC/DC
–40…+70 °C (–40…+158 °F)
–40…+100 °C (–40…+212 °F)
Temperature
Storage
Altitude
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
AgCdO
Contact Material
Terminal Markings on Socket
Sockets
In accordance with EN50 0005
700-HN153, -HN154
Certifications
cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted
UL508, CSA C22.2 No. 14, EN 61810-1
Standards
(1) See NEMA Ratings and Test Values on page 5
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
25
Relay and Timer Specifications
Technical Data - 700-HB Relays
Load (kVA)
Contact life versus AC1 load at 600 cycles/h.
Voltage DC (V)
Breaking capacity for DC1 load at 600 cycles/h.
Load applied to one contact.
A = for N.O. types
B= other types
(Highly Resistive)
COS φ
(Inductive)
Load Reduction factor versus cos φ
26
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HB Relays
Approximate Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
60.9
(2.40)
30.25
(1.19)
35.8
(1.41)
38.2
(1.50)
27.0
(1.06)
40
(1.57)
34.3
(1.35)
Ø 3.2
(0.13)
91.3
(3.59)
51.4
(2.02)
35.4
(1.39)
95.3
(3.75)
46.3
(1.82)
21.6
(0.85)
32.0
(1.26)
35.5
(1.40)
700-HB Relay
Cat. No. 700-HN153
2
Wire Size: 2 x 2.5 mm
Single Wire – Up to #12 AWG
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG), Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
49.5
(1.95)
25.6
(1.01)
35.4
(1.40)
38.0
(1.50)
84.85
(3.34)
54
(2.13)
84.3
(3.32)
41.5
(1.63)
6.3
4.0
(0.16)
(0.25)
10.5
(0.41)
Cat. No. 700-HN154
Wire Size: 2 x 2.5 mm
Cat. No. 700-HT3
2
2
Wire Size: 2 x 1.5 mm (#2 – 16 AWG…#1–20 AWG)
(Either Solid or Stranded)
Single Wire – Up to #12 AWG
2
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG), Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
27
Relay and Timer Specifications
700-HD Flange Mount Square Base Relay
•
•
•
•
Flange-mounted/panel-mounted
15 A contact rating
DPDT, 3PDT
Blade-style quick connect terminals (0.187 x 0.020)
•
Solder terminals (no socket required)
Wiring Diagrams
U.S./Canada
Photo
Contact Rating
Coil Voltage
Cat. No.
International
6V AC
700-HD32A06
700-HD32A12
700-HD32A24
700-HD32A1
700-HD32A20
700-HD32A2
700-HD32Z06
700-HD32Z12
700-HD32Z24
700-HD32Z48
700-HD32Z1
700-HD33A06
700-HD33A12
700-HD33A24
700-HD33A1
700-HD33A20
700-HD33A2
700-HD33Z06
700-HD33Z12
700-HD33Z24
700-HD33Z48
700-HD33Z1
12V AC
24V AC
120V AC
208V AC
240V AC
6V DC
32
DPDT
2-Pole
34
31
15 A
2 Form C
AgCdO Contacts
12V DC
24V DC
48V DC
110V DC
6V AC
Input
12V AC
24V AC
120V AC
208V AC
240V AC
6V DC
3PDT
3-Pole
15 A
3 Form C
AgCdO Contacts
12V DC
24V DC
48V DC
110V DC
Input
Accessories - 700-HD Relays
Photo
Pkg.
Qty.
Description
Cat. No.
1492-MS5X12
1492-MS6X9
1492-MS6X12
1492-MS8X9
1492-MS8X12
1492-MP-Blank
Relay Identification Snap-in Markers
Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of
product covers.
100
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
28
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications
Attribute
- 700-HD Relays
700-HD
ElectricalRatings
Pilot Duty Rating (1)
Rated Thermal Current (I
NEMA B300
15 A(2) – 120V
)
15 A (2) – 240V,
th
Rated Insulation Voltage(Ui)
Inductive
250V IEC-300V UL/CSA
Make
Break
Hp
2-Pole
60 A
3-Pole
30 A
2-Pole
6 A
3-Pole
3 A
120VAC
3/4
2
Contacts
240VAC
30 A
15 A
3 A
1.5 A
General-purpose
Resistive
15 A, 240V AC
15 A, 30V DC
Min. Low Energy Permissible Load
Permissible Coil Voltage Variation
AC Coils
1000 mW (10V, 10 mA)
80…110% of Nominal Voltage at 50 Hz
80…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
50 Hz
3.3VA
2.2VA
60 Hz
2.85VA
1.9VA
Inrush
Sealed
DC Coils
Coil Consumption
10%
1.3 W
Maximum Contact Resistance
Must Dropout Voltage
50 MΩ
20% of Nominal V AC
10% of Nominal V DC
Design Specification/Test Requirements
Electrical
Pole-to-Pole
Contact to Coil
2500V
4000V
Dielectric Withstand
Voltage
Mechanical
Degree of Protection (Open Type) IEC 529
Mechanical lifecycles (AC/DC)
Switching Frequency Operations
Coil Voltages
IP 40
See Overview/Product Selection
3600/HR
6
6
> 10 x 10 / 30 x 10
Pickup
Operating Time
20 ms
4 ms
Dropout
Maximum Operating Rate
4 Ops/s
Minimum Low Energy Permissible Load
1000 mN (10V, 10 mA)
Environmental
Operating
–40…+70 °C (–40…+158 °F)
–40…+100 °C (–40…+212 °F )
2000 m (6560 ft)
Temperature
Storage
Altitude
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
29
Relay and Timer Specifications
Attribute
700-HD
Construction
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings
Certifications
Standards
Silver Cad. Ox.
In accordance with EN50 0005
cURs Recognized (File No. E3125, Guide NLDX2/NLDX8), CSA Certified (File No. 229473), CE Marked, UR Certified
UL 508, CSA C22.2 No. 14, EN 61810-1
(1) See NEMA Ratings and Test Values on page 5.
(2) 3-pole relays have a 20 A maximum total current rating for all three poles.
Voltage DC (V)
Load (kVA)
Contact life versus AC1 load at 600 cycles/h.
Breaking capacity for DC1 load at 600 cycles/h.
Load applied to one contact.
A = for N.O. types
B = other types
(Highly Resistive)
COS φ
(Inductive)
Load Reduction factor versus cos φ
30
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HD Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
35.9
(1.41)
63
(2.48)
68
(2.67)
38.2
(1.50)
700-HD Relay
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
31
Relay and Timer Specifications
700-HF Square Base Relay
•
•
•
•
•
12 A contact rating
DPDT, 4PDT
Plug-in quick connect/solder terminals
Options: LED, push-to-test manual override operator
Blade size: 4.8 x 0.5 mm (0.19 x 0.02 in.)
Wiring Diagrams
U.S./Canada
Contact
Description
Photo
Coil Voltage
Cat. No.(1)
Rating
International
6V AC
700-HF32A06
700-HF32A12
700-HF32A24
700-HF32A1
700-HF32A2
700-HF32Z06
700-HF32Z12
700-HF32Z24
700-HF32Z48
12V AC
24V AC
120V AC
240V AC
6V DC
DPDT
2-pole
2 Form C
AgCdO
Contacts
12 A
12V DC
24V DC
48V DC
700-HN116
700-HN262
700-HN116
700-HN262
Socket
110V DC
700-HF32Z1
6V AC
700-HF34A06
700-HF34A12
700-HF34A24
700-HF34A1
700-HF34A2
700-HF34Z06
700-HF34Z12
700-HF34Z24
700-HF34Z48
12V AC
24V AC
120V AC
240V AC
6V DC
4PDT
4-pole
4 Form C
AgCdO Contact
12 A
12V DC
24V DC
48V DC
700-HN139
700-HN264
700-HN139
700-HN264
Socket
110V DC
700-HF34Z1
(1) Pilot Light Option: Add suffix (-4) to the selected 700-HF Relay Cat. No. except for the 240V AC units, add (-4L).
Manual Operator and LED Option: Add suffix (-3-4) to the selected 700-HF Relay Cat. No., except for the 240V AC units, add (-3-4L).
32
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories - 700-HF Relays
Photo
Description
Pkg. Qty. Cat. No.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13
sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky
backing for easy placement on relays.
10
10
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF
relays.
10
700-HN116
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction
8-blade socket for use with DPDT 700-HF relays. The socket has the ability to use optional plug-in modules (Cat.
No. 700-A_ _ accessories, LED, surge suppression, timing modules).
10
700-HN262
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction
14-blade socket for use with 4PDT 700-HF relays.
10
700-HN139
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction
14-blade socket for use with 4PDT 700-HF relays. The socket has coil and contact separation and the ability to use 10
optional plug-in modules (Cat. No. 700-A_ _ accessories, LED, surge suppression, timing modules).
700-HN264
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays and Cat. Nos.
700-HN116, 700-HN262 Sockets with 700-HF DPDT Relays§
10
10
700-HN114
700-HN266
Secures relay in socket. Order must be for 10 clips or multiples of 10.
Retainer Clip for Cat. Nos. 700-HN139 and -HN264 Sockets with 700-HF 4PDT Relays§
Secures relay in socket. Order must be for 10 clips or multiples of 10.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
33
Relay and Timer Specifications
Accessories - 700-HF Relays
Photo
Description
Pkg. Qty. Cat. No.
Diode with LED Surge Suppressor
10
10
10
10
700-ADL1
700-ADL2
700-ADL3
700-AV1R
Voltage Range: 6…24V DC used with sockets that accept plug-in accessory modules.
Diode with LED Surge Suppressor
Voltage Range: 28…60V DC used with sockets that accept plug-in accessory modules.
Diode with LED Surge Suppressor
Voltage Range: 110…220V DC used with sockets that accept plug-in accessory modules.
Varistor with LED Surge Suppressor
Voltage Range: 6…24V AC used with sockets that accept plug-in accessory modules.
Varistor with LED Surge Suppressor
Voltage Range: 110…240V AC used
10
10
10
700-AV3R
700-AR1
700-AR2
700-AT3
with sockets that accept plug-in accessory modules.
RC Surge Suppressor
Voltage Range: 6…24V AC/DC used
with sockets that accept plug-in accessory modules.
RC Surge Suppressor
Voltage Range: 110…240V AC/DC used
with sockets that accept plug-in accessory modules.
Timing Module
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC
used with sockets that accept plug-in accessory modules.
Timing Module
On-Delay or One-Shot selectable voltage range: 110…125V AC
used with sockets that accept plug-in accessory modules.
700-AT3A1
1
Timing Module
On-Delay or One-Shot selectable voltage range: 230…240V AC
used with sockets that accept plug-in accessory modules.
700-AT3A2
Socket, and Retainer Clip Reference
Relay Type
Cat. No. Socket
Cat. No. Retainer Clip
700-HN116
700-HN262
700-HF32
700-HN114
700-HN139
700-HN264
700-HF34
700-HN266
34
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications- 700-HF Relays
Electrical Ratings
700-HF 2 Pole
700-HF 4 Pole
AC 15 @ 700 VA
AC-1 @ 3000 VA
230V AC
Inductive V AC
1 Hp @ 240V AC
120V AC
DC-1
1/2 Hp @ 120V AC
12 A @ 30V DC
Contacts
VDC
0.5 A @ 110V DC
0.25 A @ 220V DC
AC
12 A @ 250 V AC (per pole)
12 A @ 30 V DC (per pole)
80…110% nom voltage
Resistive
Operating Range
Rated Power
DC
AC
DC
80…110% nom voltage
85…110% nom voltage
AC (50 Hz)
1.5 VA
1 W
2 VA
DC
AC
DC
AC
DC
1.3 W
80% nom voltage
60% nom voltage
20% nom voltage
10% nom voltage
250V AC
Holding Voltage
Must Drop Out Voltage
Insulation Voltage
Design Specification/Test Requirements
Pole-to-Pole
2500V AC
2500V AC
Dielectric Withstand Voltage
Contact to Pole
Mechanical
Degree of Protection
Mechanical Life Operations
Switching Frequency Operations
Coil Voltages
Open Type (Sockets)
20 x 106
3600/hr
See Product Selection
Pickup
8 ms
3 ms
10 ms
4 ms
Operating Time at nom voltage
at 20 °C
Dropout
Maximum Operating Rate
Vibration
4 Ops/s
15 G
Shock
15 G
Environmental
Operating
Storage
–40…+70 °C (–40…+268 °F)
–50…+80 °C (–89…+176 °F)
2000 m (6560 ft)
Temperature
Altitude
Construction
Insulating Material
Enclosure
Molded High-Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings on Socket
Sockets
Silver Cad. Oxide
In accordance with EN50 0005
8-Blade Socket (DPDT) Cat. No. 700-HN116 & 700-HN262, 14-Blade Socket (4PDT) Cat. No. 700-HN139 & 700-HN264
CSA Certified (File No. 229473), UL Recognized (File No. E3125, Guide NLDX2/NLDX8), CE Marked,
Certifications
Standards
UL Listed when used with sockets shown above, (File No. E3125, Guide NLDX/NLDX 7), LR Certified, RINA Certified, IMQ Certified
UL 508, CSA 22.2 No. 14, EN-61810-1
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
35
Relay and Timer Specifications
Dimensions -700-HF Relays
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
700-HF Relay (DPDT)
700-HF (4PDT)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Approx.
Shipping Wt.
Cat. No.
199-DR1
199-DR4
A
B
C
D
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
1.85 kg
(4.07 lb) (10/pkg)
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
3.68 kg
(8 lb) (5/pkg)
36
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HF Relays
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 700-HN116
Wire Size: 2 x 2.5 mm2
Single Wire – Up to #12 AWG
Double Wire – 2.5 mm2 (14 … 20 AWG), Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Cat. No. 700-HN262
Wire Size: Solid - 1x6/ 2 x 2.5 mm2
1x10 / 2 x 14 AWG
Stranded - 1x4 / 2x2.5 mm2
1x12 / 2x14 AWG
Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb• in)
300V AC, 12 A, 50 °C
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
37
Relay and Timer Specifications
Cat. No. 700-HN139
Wire Size: 2 x 2.5 mm2
Single Wire – Up to #12 AWG
Double Wire – 2.5 mm2 (14 … 20 AWG), Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Cat. No. 700-HN264
Wire Size: Solid - 1x6/ 2 x 2.5 mm2
1x10 / 2x14 AWG
Stranded - 1x4 / 2x2.5 mm2
1x12 / 2x14 AWG
Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb•in)
300V AC, 10 A, 70 °C
38
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HC Miniature Ice Cube Relay
•
•
•
•
•
•
•
7 or 10 A contact ratings
2PDT or 4PDT
Standard ON/OFF flag indicator
Blade-style terminals (2.0 x 0.5 mm)
Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts for low-energy applications
Options: LED, push-to-test with manual override option
Tungsten UL Approvals
•
•
4-Pole: 5A @ 24V DC
2-Pole: 10A @ 24V DC
Wiring Diagrams
U.S./Canada
Photo
Contact Rating
Coil Voltage Cat. No.(1)
International
12V DC
24V DC
24V AC
700-HC22Z12
700-HC22Z24
700-HC22A24
2PDT
10 A
2-Pole
C300
2 Form C
Contacts:
10 A = AgNi
Contacts
R300
Low energy rating;
(10V, 10 mA)
100 mW
120V AC
700-HC22A1
Input
700-HN103
700-HN104
700-HN128
240V AC
700-HC22A2
6V AC
700-HC14A06
700-HC14A12
700-HC14A24
700-HC14A1
700-HC14A2
700-HC14Z06
700-HC14Z12
700-HC14Z24
700-HC14Z48
700-HC14Z1
700-HC24A06
700-HC24A12
700-HC24A24
700-HC24A1
700-HC24A2
700-HC24Z06
700-HC24Z12
700-HC24Z24
700-HC24Z48
700-HC24Z1
12V AC
24V AC
120V AC
240V AC
6V DC
4PDT
4-Pole
4 Form C
Contacts:
7 A
Low energy rating;
(5V, 10 mA or 25V, 2 mA)
50 mW
7A = AgNiAu
Gold Plated
Contacts
12V DC
24V DC
48V DC
110V DC
6V AC
12V AC
24V AC
120V AC
240V AC
6V DC
Input
4PDT
7 A
4-Pole
C300
4 Form C
Contacts:
R300
Low energy rating;
(10V, 10 mA)
100 mW
7A = AgNi
Silver Contacts
12V DC
24V DC
48V DC
110V DC
700-HN103
700-HN104
700-HN128
(1) LED Option: Add suffix (-4) to the selected 700-HC Relay catalog number, except for the 240V AC units, add (-4L).
Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HC catalog number, except for the 240V AC units, add (-3-4L).
Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HC relay catalog number.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
39
Relay and Timer Specifications
Accessories - 700-HC Relays
Photo
Pkg.
Qty.
Description
Cat. No.
Diode with LED Surge Suppressor
Voltage Range: 6…24V DC
used with 700-HN104 socket
10
10
10
10
10
10
10
700-ADL1
Diode with LED Surge Suppressor
Voltage Range: 28…60V DC
used with 700-HN104 socket
700-ADL2
700-ADL3
700-AV1R
700-AV3R
700-AR1
Diode with LED Surge Suppressor
Voltage Range: 110…220V DC
used with 700-HN104 socket
Varistor with LED Surge Suppressor
Voltage Range: 6…24V AC
used with 700-HN104 socket
Varistor with LED Surge Suppressor
Voltage Range: 110…240V AC
used with 700-HN104 socket
RC Surge Suppressor
Voltage Range: 6…24V AC/DC
used with 700-HN104 socket
RC Surge Suppressor
Voltage Range: 110…240V AC/DC
used with 700-HN104 socket
700-AR2
Timing Module
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used
with sockets that accept plug-in accessory modules.
700-AT3
Timing Module
On-Delay or One-Shot selectable voltage range: 110…125V AC used
with sockets that accept plug-in accessory modules.
1
700-AT3A1
700-AT3A2
Timing Module
On-Delay or One-Shot selectable voltage range: 230…240V AC used
with sockets that accept plug-in accessory modules.
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade
miniature socket for use with 700-SC Relays.
10
700-HN103
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade
miniature socket for use with 700-HC relays. This socket has coil and contact separation as well as the ability to plug in 10
optional plug in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules)
700-HN104
700-HN128
Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade
miniature socket for use with 700-HC Relays.
10
40
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Photo
Pkg.
Qty.
Description
Cat. No.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays.
10
10
700-HN114
700-HN124
Secures relay in socket.(1)
Plastic Retainer and Ejection Lever
For use with the 700-HN104 Sockets for 700-HC relays.
Built-in ability to accept 1492 Snap-in Markers
(1) See 700-HC Miniature Square Base Relay, Socket, and Retainer Clip Reference Chart.
Description
Pkg. Qty. Cat. No.
Photo
5
1492-MS5X12
1492-MS6X9
1492-MS6X12
1492-MS8X9
1492-MS8X12
1492-MP-Blank
5
Relay Identification Snap-in Markers
Snap-in markers fit on top of product covers. Squares slip into molded slot on top of product
cover.
5
5
5
100
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank
tags. Tags are peel-off with sticky backing for easy placement on relays.
10
50
700-N40
Markers — Used for terminal identification
700-N41
Socket and Retainer Clip Reference
Relay Type
Socket Cat. No.
700-HN103
Retainer Clip Cat. No.
700-HN114
700-HC
700-HN128
700-HN114
700-HN104
700-HN114 or 700-HN124
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
41
Relay and Timer Specifications
Specifications- 700-HC Relays
Attribute
700-HC
Electrical Ratings
Pilot Duty Rating (1)
NEMA C300, R300
7 A and 10 A
Rated Thermal Current (I
)
th
Rated Insulation Voltage (U )
250V IEC – 300V UL/CSA
i
700-HC_4
Hp
700-HC22
Hp
Inductive
Make
Break
Make
Break
120VAC
15 A
1.5 A
1/8
1/3
15 A
1.5 A
1/3
3/4
Contacts
240VAC
7.5 A
0.75 A
7.5 A
0.75 A
General-purpose
Resistive
7 A, 277V AC
7 A, 30V DC
10 A, 277V AC
10 A, 24V DC
100 mW (10V, 10 mA) - Silver Contacts
50 mW (5V, 10 mA, or 25V, 2 mA) - Gold Contacts
Min. Low Energy Permissible Load
Permissible Coil Voltage Variation
80…110% of nom voltage at 50 Hz
80…110% of nom voltage at 60 Hz
80…110% of nom voltage at DC
20% of nom voltage at AC
10% of nom voltage at DC
Must Dropout
Voltage:
Pickup:
50 Hz
2.2VA
1.3VA
60 Hz
Inrush
Sealed
1.6VA
1.1VA
Coil
Consumption
10ꢀ
AC Coils
DC Coils
1.0 W
20% of VA (AC)
10% of W (DC)
Max. Allowable Leakage
DesignSpecification/TestRequirements
Electrical
Pole-to-Pole
2000V
2000V
Dielectric Withstand Voltage
ElectricalLife (Cycles)
Contact to Coil
100,000 min
Mechanical
Degree of Protection (Open Type) IEC 529
Mechanical lifecycles
IP 20 (Guarded Terminal Sockets)
6
6
20 x 10 (AC), 50 x 10 (DC)
1800/HR
Switching Frequency Operations
Coil Voltages
See Product Selection
10 ms
Pickup
OperatingTime
Dropout
3 ms
Maximum Operating Rate
8 cycles/s
Environmental
Operating
Storage
–30…+55 °C (–22…+131 °F)
–55…+85 °C (–67…+185 °F)
2000 m (6560 ft)
Temperature
Altitude
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings on Socket
Sockets
AgNi(700-HC2), AgNi + 5 μm All (700-HC1)
In accordance with EN50 0005
700-HN103, -HN128, -HN104
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), cULus Listed when used with 700- HN103, -HN104, and -HN128 sockets
(File No. E14843, Guide NRNT/NRNT7), CE Marked, LR Certified
Certifications
Standards
UL 508, CSA 22.2 No. 14, EN 61810-1
(1) See General Information on page 3.
42
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions, 700-HC Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
37.2
(1.46)
36.7
(1.44)
5.6
(0.22)
6.1
(0.24)
27.7
(1.09)
20.7
(0.82)
20.7
(0.82)
27.7
(1.09)
700-HC Relay (Two-Pole)
700-HC Relay (Four-Pole)
27.0
(1.06)
60.9
(2.40)
21.5
(0.85)
76.0
(2.99)
35.6
(1.40)
3.2
(0.13)
18.9
(0.74)
34.9
(1.37)
32.0
(1.26)
35.5
(1.40)
2.5
(0.10)
Cat. No. 700-HN104
2
2
2
Single Wire: 0.2 mm …2.5 mm (24 AWG…14 AWG), Double Wire: 0.2 …2.5 mm (24 AWG…14 AWG), Qty. 2 wires
Wire Type: solid or stranded, copper only, Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
30.0
24.9
(57/64)
21.1
(1-3/16)
Panel Mounting
6.1 (15/64)
(53/64)
5
1
8
4
6
2
7
3
28.9
(1-9/64)
24.5
(31/32)
67.0
(2-5/8)
4.2
(5/32)
62.0
(2-15/64)
65.0
(2-9/16)
14
12
13
9
11
10
#4-40
M3
30.0
(1-11/64)
26.0
(1-1/64)
Cat. No. 700-HN103
Cat. No. 700-HN128
2
2
2
Single Wire: 0.2 mm …2.5 mm (#24 AWG…14 AWG)
Wire Size: 2 x 1.5 mm (#2-16 AWG…#1-20 AWG)
(Either Solid or Stranded)
2
Double Wire: 0.2…2 x 1.5 mm (24 AWG…16 AWG), Qty. 2 wires
Wire Type: Solid or Stranded, Copper only
Strip Length: 9 mm (3/8 in.) – Toque: 0.8 N•m (7 lb•in)
Strip Length: 8 mm (5/16 in.), Torque: 0.5 N•m (4.4 lb•in)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
43
Relay and Timer Specifications
700-HK Slim Line Relay
•
•
•
•
•
8 A/16 A contact ratings
DPDT/SPDT
Plug-in blade-style terminals (2.5 x 0.5 mm)
Retainer clip with sockets
Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or
timer module
•
•
•
•
Standard ON/OFF flag indicator
Relay faceplate accepts optional Bulletin1492 snap-in markers
Choice of standard silver/nickel contacts or silver/nickel with gold plated contacts
Maximum duty version available
Wiring Diagrams
Photo
Description
Contact Rating
Coil Voltage
Cat. No.(1)
U.S./Canada
International
6V AC
700-HK36A06
700-HK36A12
700-HK36A24
700-HK36A1
700-HK36A2
700-HK36Z06
700-HK36Z12
700-HK36Z24
700-HK36Z48
12V AC
24V AC
120V AC
240V AC
6V DC
SPDT
1-Pole
1 Form C
AgNi Contacts
16 A
12V DC
24V DC
48V DC
Input
700-HN121, 700-HN221,
700-HN223
700-HN121, 700-HN221,
700-HN223
Socket
110V DC
700-HK36Z1
6V AC
700-HK32A06
700-HK32A12
700-HK32A24
700-HK32A1
700-HK32A2
700-HK32Z06
700-HK32Z12
700-HK32Z24
700-HK32Z48
12V AC
24V AC
120V AC
240V AC
6V DC
DPDT
2-Pole
2 Form C
AgNi Contacts
8 A
12V DC
24V DC
48V DC
Input
700-HN122, 700-HN222,
700-HN224
700-HN122, 700-HN222,
700-HN224
Socket
110V DC
700-HK32Z1
(1) Options
Pilot Light: Add suffix (-4) to the selected 700-HK Relay catalog number except for the 240V AC units, add (-4L).
Manual Operator and LED: Add suffix (-3-4) to the selected 700-HK Relay catalog number, except for the 240V AC units, add (-3-4L).
AgNi Contact with Gold plating: Replace “3”with “X”om catalog number. For example, if catalog number 700-HK36A1 is required with gold plating, the new catalog number is 700-HKX6A1.
For high inductive, Tungsten, or Capacitive load applications, replace the “3”with a “M”in the catalog number. Only available in a SPDT configuration and with 24V DC, 120V AC, or 240V AC coil voltages.
44
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories- 700-HK Relays
Photo
Description
Pkg. Qty. Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for
use with 1-pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip.
10
700-HN121
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 16 A rating for
use with 1-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal
construction and compatible with optional plug-in module accessories.
10
10
700-HN221
700-HN223
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting
5-blade miniature socket for use with 1-pole, 700-HK relays.
Screw Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket with 5 A rating for use with 2-pole, 700-HK relays. Accepts forked lug
conductors. This socket includes a retainer clip.
10
700-HN122
Screw Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket with 8 A rating for use with 2-pole, 700-HK relays. Retainer clips are packaged
separately with socket. Guarded terminal construction and compatible with optional plug-in module
accessories.
10
10
700-HN222
700-HN224
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket for use with 2-pole 700-HK relays.
Flange Mount Adapter
10
10
10
700-HN226
700-HN227
700-HN229
Used for panel-mounting bulletin 700-HK relays. Order must be for 10 adapters or multiples of 10.
35 mm Rail Mount Adapter
Mounts bulletin 700-HK relays to a 35 mm rail. Order must be for 10 adapters or multiples of 10.
Socket Retainer Clip and Ejection Lever
For use with 700-HN22, -HN222, -HN223, and -HN224 sockets. Orders must be for 10 clips or
multiples of 10.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
45
Relay and Timer Specifications
Specifications- 700-HK Relays
Attribute
700-HK
Electrical Ratings
Rated Thermal Current (I
)
1-Pole, 1 CO, SPDT — 16 A
2-Pole, 2 CO, DPDT — 8 A
th
Rated Insulation Voltage(Ui)
250V IEC, 300V UL/CSA
AC-15, 6.2 A
AC-15, 2.9 A
120VAC
B300 Pilot Duty, 3 A A300 (700-HKM_)
1/3 Hp (0.24 kW) 1-phase
120VAC
240VAC
B300 Pilot Duty, 3.0 A 1/4 Hp (0.18 kW), 1-phase
Inductive V AC
AC-15, 3.1 A
B300 Pilot Duty, 1.5 A A300(700-HKM_)
3/4 Hp (0.55 kW), 1-phase
AC-15, 1.4 A
B300 Pilot Duty, 1.5 A 1/2 Hp (0.37 kW), 1-phase
240VAC
230VAC
24VDC
0.55 kW, 1-phase
DC-13, 5.0 A
230VAC
24VDC
0.37 kW, 1-phase
DC-13, 3.0 A
Contacts
Inductive V DC
Resistive
125VDC
250VDC
230V AC
277VAC
DC-13, 0.2 A / R300 Pilot Duty, 0.22 A
DC-13, 0.1 A / R300 Pilot Duty, 0.11 A
AC-1, 16 A
125VDC
DC-13, 0.2 A / R300 Pilot Duty, 0.22 A
DC-13, 0.1 A / R300 Pilot Duty, 0.11 A
AC-1, 8 A
5 A, 250V AC
230V AC
16 A, General Use
277VAC
8 A, General Use
Make, Break , and
Continuous
30VDC
DC-1, 12 A / 10 A, Resistive
30VDC
DC-1, 6 A / 6 A, Resistive
300 mW (5V/60 mA or 60V/5 mA) for AgNi Contacts (700-HK3_)
50 mW (5V/10 mA or 25V/2 mA) for AgNi + Gold Contacts (700-HKX_)
Min. Permissible Contact Ratings
500 mW (100V/5 mA or 5V/100 mA) for AgSnO Contacts (700-HKM_)
2
Pickup:
80…110% of Nominal Voltage at 50/60 Hz, 73...110% of Nominal Voltage at DC
80% of Nominal V AC at 50/60 Hz, 40% of Nominal V DC
Permissible Coil Voltage
Variation
holding Voltage:
Must Dropout
Voltage:
20% of Nominal V AC at 50/60 Hz, 10% Nominal V DC
Power Consumption
Coil Voltages
1.2V A (V AC Coils), 0.5 W (V DC Coils)
See Overview/Product Selection
Design Specification/Test Requirements
Pole to Pole (VRMS)
Contact to Coil
(VRMS)
Dielectric Withstand
Voltage
2000VAC
4000VAC
Mechanical
Degree of Protection
IP 20 (guarded terminal sockets), RT II — Flux-proof (Relay)
6
Mechanical Life Operations
10 x 10
230V AC, 16 A Resistive: 100 000 min.
230V AC, 8 A Resistive: 100 000 min.
277V AC, 8 A Resistive: 30 000 min.
30V DC, 6 A Resistive: 30 000 min.
B300, R300, Hp (kW): 6000 min.
277V AC, 16 A Resistive: 30 000 min.
30V DC, 10 A Resistive: 30 000 min.
B300, R300, Hp (kW): 6000 min.
A300 (700-HKM_): 100,000 min.
Electrical Lifecycles
Mechanical: 18,000 cycles/hr.
Electrical: 900 cycles/hr.
Switching Frequency
Pickup
15 ms
5 ms
Operating Time at Nominal
Voltage at 20 °C (ms)
Dropout
10…2000 Hz, 0.76 mm (0.03 in.) 2.5 G
10…2000 Hz, 0.76 mm (0.03 in.) 5.0 G
Operational
Vibration
Shock
Non-Operational
Operational
Non-Operational
15 G
50 G
Environmental
Construction
Operating
Storage
–40…+70 °C (–40…+158 °F)
–40…+85 °C (–40…+185 °F)
Temperature
Altitude
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings on Socket
700-HK3_: Silver nickel (AgNi); 700-HKX_: Silver Nickel + Gold Plating (AgNi + Au); 700-HKM_: Silver Tin Oxide(AgSnO )
2
In accordance with EN 50005
46
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
Sockets
700-HK
1-Pole
2-Pole
700-HN122 (2 x 5 A @ 70 °C)
700-HN222 (2 x 8 A @ 70 °C)
700-HN121 (10 A @ 70 °C)
700-HN221 (16 A @ 50 °C, 12 A @ 70 °C)
Screw Terminal
Spring Clamp
700-HN223 (15 A @ 40 °C with 2 conductors per terminal)
(10 A @ 70 °C with 1 conductor per terminal)
700-HN224 (2 x 8 A@ 70 °C)
Approvals
CSA Certified, File 75088, UL Recognized, File E3125
Guide NLDX2/NLCX8, cULus Listed with Allen-Bradley sockets (File No. 3125 Guide NLDX/NLDX7), CE Marked
EN61810-1, CSA 22.2 No. 14, UL 508
Certifications
Standards
Dimensions- 700-HK Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
12.4
(1/2)
29.0
(1-9/64)
12.4
(1/2)
29.0
(1-9/64)
32.8
(1-19/64)
30.1
(1-3/16)
32.8
(1-19/64)
30.1
(1-3/16)
6.5
(1/4)
6.5
(1/4)
2.5
(3/32)
0.5
(1/32)
4.75
0.5
(1/32)
COM 11
NC 12
2
(3/16)
3
NO 14
4
A1
8
A1
5
COM 11
4
A2
1
NO 24
5
NC 22
7
A2
1
COM 21
6
NC 12
2
NO 14
3
Cat. No. 700-HK36_ (SPDT)
Cat. No. 700-HK32_ (DPDT)
COM 11 NO 14NC 12
A1
8
COM 11 NO 14 NC 12
A1
8
3
4
2
3
4
2
15.8
(5/8)
15.8
(5/8)
COM 21 NO 24 NC 22
A2
1
COM 21 NO 24NC 22
A2
1
6
5
7
6
5
7
Cat. No. 700-HN222
Cat. No. 700-HN224
COM 11 NO 14 NC 12
A1
5
COM 11 NO 14 NC 12
A1
5
4
3
2
4
3
2
15.8
(5/8)
15.8
(5/8)
A2
1
A2
1
Cat. No. 700-HN221
Cat. No. 700-HN223
64.9
(2-9/16)
44.7
(1-3/4)
32.5
(1-9/32)
35.3
(1-25/64)
22.6
(57/64)
34.7
(1-3/8)
35.4
(1-13/32)
95.6
(3-49/64)
82.85
(3-17/64)
Cat. No. 700-HN223, 700-HN224
Wire Size: 0.2 mm ...1.5 mm (#24 AWG....#14 AWG)
Either Solid or Stranded
Cat. No. 700-HN221, 700-HN222
Wire Size: 0.2 mm ...2.5 mm (#24 AWG....#12 AWG)
Either Solid or Stranded
2
2
2
2
Strip Length: 8 mm (5/16 in)
Strip Length: 8 mm (5/16 in), Torque: 0.8Nm (7.0 lb.-in.)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
47
Relay and Timer Specifications
Dimensions - 700-HK Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
46.0
(1-13/16)
14.4
(37/64)
3.6
(9/64)
14.4
(37/64)
38.0
(1-1/2)
46.9
(1-27/32)
42.4
(1-43/64)
36.6
(1-11/16)
39.8
(1-37/64)
18.1
(23/32)
2.0
(5/64)
34.8
(1-3/8)
Cat. No. 700-HN227
Cat. No. 700-HN226
1.0
(0.04)
12.5
(1/2)
6.2
(15/64)
50
(1-63/64)
27.0
(1.06)
35.0
(1.38)
5.2
(13/64)
7.5
(0.30)
1000
(39-3/8)
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No.
199-DR1
A
B
C
D
Approx. Shipping Wt.
1.85 kg
(4.07lb)
(10/pkg)
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
3.68 kg
(8 lb)
(5/pkg)
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
199-DR4
48
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
7.11
(9/32)
2.03
(5/64)
21
6
11
3
2.03
(5/64)
7.11
(9/32)
Five M3.5
x 0.315 Screws
11
4
22
7
24
Eight
M3.5 x 0.315
Screws
4.06
(5/32)
14
3
4.06
(5/32)
12
2
5
12
2
(1)
14
3.0 Ø
39.5
(1-17/32)
35.5
(1-13/32)
39.5
(1-17/32)
4
(1/8)
84.1
(3-5/16)
84.1
(1)
Use M3 Screws
3.0 Ø
(1/8)
(3-5/16)
35.5
(1-13/32)
5 (+)
(A1)
Use M3 Screws
8 (+)
(A1)
1 (-)
(A2)
4.06
(5/32)
4.06
(5/32)
1 (-)
(A2)
29.9
(1-3/16)
15.6
(5/8)
29.9
(1-3/16)
15.6
(5/8)
54.1
(2-1/8)
54.1
(2-1/8)
Cat. No. 700-HN121
Cat. No. 700-HN122
2
2
Wire Size: 2 x 2.5 mm
Single Wire – Up to #14 AWG
Wire Size: 2 x 2.5 mm
Single Wire – Up to #14 AWG
2
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires
(Either Solid or Stranded)
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
49
Relay and Timer Specifications
700-HL Terminal Block Relay
•
Relay and socket assembled interface modules for high density interposing or isolation
applications
•
•
•
•
•
•
•
•
•
Screw terminal and spring-clamp bases
6 A relay, choice of silver or gold contacts
2 A solid-state relay — DC output
2 A solid-state relay — AC output
SPDT (relay), 1 N.O. (solid-state)
Built-in retainer clip and snap-in marker lever
Standard LED, reverse polarity protection, and surge protection
Externally replaceable relay modules
Unique leakage current suppression version to address industry concerns of nuisance coil turn-on or contact non-drop out when connecting
to PLCs with leakage current
•
Available with hazardous location certification
Standard built-in Features:
•
•
LED
Reverse Polarity Protection
for DC Inputs
•
Coil Surge Protection(1)
Cat. No. 700-HLT1Z24
Cat. No. 700-HLT2Z24
Cat. No. 700-HLS1Z24
Cat. No. 700-HLS11Z24
(3)
Specifications
Output Type
SPDT (1 C/O); Ith =6A(2)
1 N.O. solid-state; Ith = 2 A, 24V DC or Ith =2 A, 240V AC
Recommended Tightening
Torque
0.5 N• m max. (4.4 lb• in)
Wire Range
Screw Terminal: 0.14 mm2…2.5 mm2 (#26…#14 AWG), Spring Terminal: 0.2 mm2…2.5 mm2 (#24…#14 AWG)
UL, cULus, cURus, ABS, CE
Approvals
(1) Diode surge protection provided.
(2) For Gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-HLT1Z24 is required with gold plating, the new cat. no. is 700-HLT1Z24X.
(3) Reverse polarity on the output terminals of the solid-state relay will result in the output being "ON" regardless of the state of the input voltage.
Cat. No.
(Spring Clamp
Terminals)
Cat. No.
(Spring Clamp
Terminals)
Cat. No.
Pkg. Quantity (Screw Terminals)
(DC Output)
Cat. No.
(Screw Terminals)
(AC Output)
Pkg.
Qty.
Cat. No.
(Screw Terminals)
Input Voltage
(DC Output)
(2)
12V DC
10
10
10
10
10
10
10
10
10
700-HLT1Z12 700-HLT2Z12
700-HLT1Z24 700-HLT2Z24
700-HLT1Z48 700-HLT2Z48
—
10
—
(2)
—
—
(2)
(2)
24V DC
700-HLS1Z24
700-HLS1Z48
700-HLS2Z24
700-HLS2Z48
—
700-HLS11Z24
700-HLS11Z48
—
(2)
48V DC
10
12V AC/DC
24V AC/DC
48V AC/DC
110/125V AC/DC
220…240V AC/DC
240V AC
700-HLT1U12
700-HLT1U24
700-HLT1U48
700-HLT1U1
700-HLT1U2
700-HLT1A2
700-HLT2U12
700-HLT2U24
700-HLT2U48
700-HLT2U1
700-HLT2U2
—
—
—
—
10
—
—
—
—
—
(2)
—
—
700-HLS1U1
700-HLS1U2
700-HLS2U1
700-HLS2U2
—
700-HLS11U1
700-HLS11U2
—
(2)
10
—
—
50
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Cat. No.
Cat. No.
(Spring Clamp
Terminals)
Cat. No.
Pkg. Quantity (Screw Terminals)
(DC Output)
Cat. No.
(Screw Terminals)
(AC Output)
Pkg.
Qty.
Cat. No.
(Screw Terminals)
(Spring Clamp
Terminals)
(DC Output)
Input Voltage
Built-in LCSC (leakage
current suppression
circuit)
(2)
(2)
10
10
700-HLT1L1
—
—
10
10
700-HLS1L1
700-HLS1L2
—
—
700-HLS11L1
700-HLS11L2
120V AC and 125V DC(1)
Built-in LCSC (leakage
current suppression
circuit) 240V AC (1)
(2)
(2)
700-HLT1L2
Hazardous Location
Certification 24V DC
10
10
700-HLT1Z24-EX
700-HLT1Z12-EX
—
—
10
10
700-HLS1Z24-EX
—
—
—
—
—
Hazardous Location
Certification 12V DC
Hazardous Location
Certification 110/125V 10
AC/DC
700-HLT1U1-EX
—
10
700-HLS1U1-EX
—
—
(1) Leakage current suppression up to 2.2 mA off state current.
(2) Electromechanical relay to solid-state relay interchangeability is possible.
Accessories
-
700-HLT, -HLS Relays
Description
Pkg.
Quantity
Photo
Socket Input Voltage
Cat. No.
12V AC/DC
24V AC/DC
48V AC/DC
700-TBR12
700-TBR24
700-TBR48
Replacement Relays(1)
20
20
Order must be for 20 relays or multiples of 20.
110/125V AC/DC
220…240V AC/DC
700-TBR60
24V DC
700-TBS24
700-TBS60
Replacement SSR
4-blade miniature relay for use with 1 N.O. SSR DC output.
Order multiples of 20.
48V DC, 110/125V AC/DC
220…240V AC/DC
Replacement SSR
4-blade miniature relay for use with 1 N.O. SSR AC output.
Order multiples of 20.
20
20
24V DC
700-TBS124
700-TBS160
Replacement SSR
4-blade miniature relay for use with 1 N.O. SSR AC output.
Order must be for 20 relays or multiples of 20.
48V DC
110/125V AC/DC
220…240V AC/DC
Color
Red
700-TBJ20R
700-TBJ20G
20-Way Jumper Can be cut to required length.
Ith =36 A max per 20-way jumper.
1
Grey
Blue
700-TBJ20B
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
51
Relay and Timer Specifications
Pkg.
Quantity
Photo
Description
Socket Input Voltage
Cat. No.
End Barrier
Used for visual inspection of groups, safe separation of
neighboring 700-HL modules that end with jumpers.
10
Black
700-HN177
Snap-in Marker
These snap-in markers have a 6 x 10 mm surface and snap into
the ejection lever for the relay. For custom markers, contact your local
Rockwell Automation sales office or Allen-Bradley distributor for more
information.
100
Blank
1492-MC6X10
(1) For gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X.
Dimensions - 700-HL Relays
700-HL Spring Terminal Design Single Wire: 0.2 mm2…2.5 mm2 (#24 AWG…#14 AWG ) Wire Type: Solid or stranded, copper only.Strip Length: 9 mm (11/32 in.)
Cat. No. 199-DR1 DIN Mounting Rail Series B, Cat. No. 199-DR4 DIN Mounting Rail Series B has no mounting holes.
Specifications - 700-HLT Relays
Cat. No. 700-HLT… (Relay Output)
Electrical Ratings
Pilot Duty Rating
B 300, R 300
1-Pole — 6 A
250V IEC, 300V UL/CSA
1-Pole
Rated Thermal Current (I
)
th
Rated Insulation Voltage(Ui)
24VAC, 1-phase
120VAC, 1-phase
240VAC, 1-phase
30 A
30 A
15 A
5 A
3 A
Inductive V AC
Inductive V DC
Break
Make
1.5 A
24VDC
125VDC
240VDC
24VDC
DC-13, 1.0 A
DC-13, 0.2 A
DC-13, 0.1 A
6.0 A
Contacts
Resistive
Make, Break, and
Continuous
250VAC
240VDC
6.0 A
0.1 A
AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact
Inductive Load
DC-13 24V, 1 A N.O., and N.C. Contact
52
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Cat. No. 700-HLT… (Relay Output)
12V, 6 mA (72 mW) for Silver Contacts,
Min. Permissible Contact Ratings
Permissible Coil Voltage Variation
Power Consumption 10%
8V, 2.5 mA (20 mW) for Gold Contacts
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Must Dropout
Voltage:
10% of Nominal Voltage at AC
5% of Nominal Voltage at DC
Pickup:
AC
DC
0.3VA
0.2 W
Design Specification / Test Requirements
Pole to Pole
(VRMS)
1000V
4000V
Dielectric Withstand Voltage
Contact to Coil
(VRMS)
Input Voltage
12V AC/DC
1K
24V AC/DC
2 K
48V AC/DC
6 K
120V AC/DC
26 K
240V AC/DC
56 K
120VLCSC
16 K
240VLCSC
35 K
Impedance(Ohms)
Mechanical
Degree of Protection
IP20
7
Mechanical Life Operations
1 x 10
6 A Resistive: 100 000 min.
Electrical Life Operations
24V DC, 1 A Inductive: 200 000 min.
120V AC 1 A Inductive: 300 000 min.
Switching Frequency Operations (no-load)
Coil Voltages
10 cycles/sec
See Overview/Product Selection
Pickup
7 ms
3 ms
Operating Time at Nominal Voltage at 20 °C (ms)
Dropout
Maximum Operating Rate (full load = 6 A)
Coil Surge Protection
6 cycles/min.
Per EN 61000-4.5; Surge Immunity (801-5)
Class III: 2 kV common and 1 kV differential mode
Environmental
Operating
Storage
–40…+55 °C
–40…+100°C
Temperature
Altitude
2000 m (6560 ft)
Construction
Insulating Material
Enclosure
Molded High Dielectric Material
RelayIP67
Contact Material
Terminal Markings on Socket
Silver Tin Ox, AgSnO or Silver with Gold Plating, AgSnO + Au
2
2
In accordance with EN50 0005
cULus Listed (File No. E3125, E14843 Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked, ABS
(American Bureau of Shipping)
Certifications
Standards
EN 61810-1, CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant
Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta< 55 °C
700-HLT1Z12-EX(12V DC supply)
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply)
UL Listed
(UL60079-15)
Hazardous Location Approvals
CSA Certified (1)
(CAN/CSA
E60079-15)
700-HLT1Z12-EX(12V DC supply)
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.
Cat. No. 700-HLS… (Solid-state Output)
Electrical
Rated Thermal Current (I
)
2 A (DC output)
2 A (AC output)
th
Rated Insulation Voltage(Ui)
250V IEC, 300V UL/CSA
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
53
Relay and Timer Specifications
Cat. No. 700-HLS… (Solid-state Output)
Min. Control Voltage
80% nominal voltage
110% nominal voltage
Maximum Control Voltage
Control Current
9 mA 10% (24V) 4 mA 10% (120/240V)
0.4 x nominal voltage (24V), 0.35 x nominal voltage (120/240V)
Control Circuit
Release Voltage
3200 ohms (24V),
16k ohms (120V),
32k ohms (240V)
2500 ohms (24V),
12k ohms (120V),
24kohms(240V)
Min. Control Circuit Resistance
Load Voltage Range
0…24VDC
33V
24…240VAC
600V
Max. Repetitive Blocking Voltage
Max. Switching Current (inductive/
resistive)
2 A DC
1 A AC
Outputs
On State Voltage Drop @ Max.
Switching Current
<120 mV DC
<1VAC
Leakage Current
max.100μA(@U=24V)
AC
DC
0.6VA(120V),1VA(240V)
Power Consumption 10%
Dielectric Withstand Voltage
0.2 W
Design Specification/TestRequirements
0.3 W
Pole to Pole (VRMS)
Contact to Coil (VRMS)
24VDC
2500V
2500V
Input Voltage
48VDC
9 K
120V AC/DC
240V AC/DC
58 K
120VLCSC
16 K
240VLCSC
35 K
Impedance(Ohms)
2K
26 K
Mechanical
Degree of Protection
Input Voltages
IP20
See Overview/Product Selection
Turn on Time
30 μs (DC only input voltage), 7 ms (AC/DC input voltage)
350 μs (DC only input voltage), 10 ms (AC/DC input voltage)
300 Hz
Operating Time at Nominal Voltage at
20 °C (ms)
Drop Out Time
Maximum Operating Rate
Environmental
Construction
Operating
Storage
–20…+55 °C
–40…+70 °C
Temperature
Altitude
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High-Dielectric Material
RelayIP67
Terminal Markings on Socket
Certifications
In accordance with EN50 0005
cULus Listed (File No. E14843, Guide NLDX/NLDX7), CE Marked, ABS (American Bureau of Shipping)
UL 508, CSA C22.2 No. 14, EN 61810-1
Standards
Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta < 55 °C
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply)
UL Listed
(UL60079-15)
Hazardous Location Approvals
CSA Certified (1)
(CAN/CSA60079-15)
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.
54
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HLT, -HLS Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
76.0
(2.99)
76.0
(2.99)
93.0
(3.66)
88.0
(3.46)
6.2
(0.24)
6.2
(0.24)
700-HLT / -HLS Screw Terminal Design
700-HLT / -HLS Spring Terminal Design
2
2
2
2
Single Wire: 0.14 mm …2.5 mm (#26 AWG…#14 AWG)
Single Wire: 0.2 mm …2.5 mm (#24 AWG…#14 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in.)
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x #16 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in). Torque: 0.5 N•m (4.4 lb•in)
Dimensions - 700-HLT, -HLS Relay Accessories
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
199-DR1
199-DR4
A
B
C
D
Approx. Shipping Wt.
1.85 kg (4.07lb)
3.68 kg (8 lb)
Pkg. Qty.
10/pkg
5/pkg
35 (1-3/8)
35 (1-3/8)
27 (1-1/16)
27 (1-1/16)
7.5 (19/64)
15 (19/32)
1.02 (1/64)
2.3 (3/32)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
55
Relay and Timer Specifications
700-HL 2-pole Terminal Block Relay
•
•
•
•
•
•
•
Relay and socket assembled interface modules for high density interposing or isolation applications
Screw terminal and spring-clamp bases
10 A relay, choice of silver or gold contacts
DPDT (relay)
Built-in retainer clip and snap-in marker lever
Standard LED, reverse polarity protection, and surge protection
Externally replaceable relay modules
Output Type
DPDT (2 C/O); Ith = 10 A
Recommended Tightening Torque
Wire Range
0.6 N•m max. (5.3 lb•in.)
Screw Terminal: 0.2…2.5 mm2 (#24…14 AWG), Spring Terminal: 0.2…2.5 mm2 (#24…14 AWG)
Approvals
cULus, cURus, CE
Input Voltages
12V DC
Pkg. Quantity
Cat. No.(1) (Screw Terminals)
700-HLT12Z12
Cat. No.(Spring Clamp Terminals)
700-HLT22Z12
10
10
10
10
10
10
24V DC
700-HLT12Z24
700-HLT22Z24
48V DC
700-HLT12Z48
700-HLT22Z48
24V AC/DC
700-HLT12U24
700-HLT22U24
110/125V AC/DC
220…240V AC/DC
700-HLT12U1
700-HLT22U1
700-HLT12U2
700-HLT22U2
(1) For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24 with gold plated contacts is Cat. No. 700-HLT12Z24X. The following relays are available with the gold-plated contact
option: 700-HLT_2Z24, 700-HLT_2U24, 700-HLT_2U1, and 700-HLT_2U2. Not available on 12V and 48V DC products.
Accessories - 700-HL Relays (2- pole)
Pkg.
Qty.
Photo
Description
Socket Input Voltage/Color
Cat. No.
12V DC
700-TBR212
700-TBR224
700-TBR248
700-TBR2110
700-TBJ08R
700-TBJ08G
700-TBJ08B
Replacement Relays
Order must be for 20 relays or multiples 20
of 20.
24V AC/DC
48V DC
110/125V AC/DC, 220…240V AC/DC
Red
8-Way Jumper
Can be cut to required length. Ith
=
1
Grey
Blue
10 A max per 8-way jumper.
End Barrier
Used for visual inspection of groups,
safe separation of neighboring 700-HL
modules that end with jumpers.
10
Black
Blank
700-HN177
Snap-in Marker(1)
These snap-in markers have a 6 x 12
mm surface and snap into the ejection
lever for the relay.
100
1492-MS6X12
(1) For custom markers, contact your local Rockwell Automation sales office or Allen-Bradley distributor for more information.
56
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HL Relays (2-Pole)
Cat. No. 700-HLT…2-Pole (Relay Output)
Electrical Ratings
Pilot Duty Rating
B 300, R 300
2-Pole — 10 A
Rated Thermal Current (I
)
th
Rated Insulation Voltage(Ui)
250V IEC, 300V UL/CSA
120VAC
240VAC
AC-15, 3.0A B 300, 3.0 A
1/4 HP (186 W), 1-phase
1/2 HP (373 W), 1-phase
Inductive V AC
UL
AC-15, 3.0 A
B 300, 1.5 A
24VDC
125VDC
250VDC
250VAC
24VDC
DC-13, 2.0 A
DC-13, 0.3 A
DC-13, 0.2 A
10 A
Contacts
Inductive V DC
Resistive Make,
Break
,
and
10 A
Continuous
250VDC
0.28 A
Min. Permissible Contact Ratings
Permissible Coil Voltage Variation
12V, 10 mA (120 mW) for Silver Contacts, 5V, 1 mA (50 mW) for Gold Contacts
Nominal
10% of
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Voltage at AC
Must Dropout
Voltage:
Pickup:
5% of Nominal
Voltage at DC
DesignSpecification/TestRequirements
Pole to Pole
(VRMS)
1000V
5000V
Contact to Coil
(VRMS)
Dielectric Withstand Voltage
Input Voltage
Adjacent
Contacts
(VRMS)
2500V
12V AC/DC
1 K
24V AC/DC
2 K
48VDC
3 K
120V AC/DC
34 K
240V AC/DC
72 K
0.8VA
0.7 W
Impedance(Ohms)
AC
DC
N/A
0.5VA
0.5 W
N/A
0.4VA
Power Consumption 10%
0.4 W
0.8 W
0.5 W
Mechanical
Degree of Protection
IP20
7
Mechanical Life Operations
3 x 10
250V AC/24V DC, 8 A Resistive: 100 000 min.
24V DC, 10 A Resistive: 6000 min.
Electrical Life Operations
250V DC, 0.28 A Resistive: 6000 min.
250V AC, 10 A Resistive: 30 000 min.
Switching Frequency Operations (no-load)
Coil Voltages
1200 cycles/sec
See Overview/Product Selection
typical 10 ms
Pickup
Operating Time at Nominal Voltage at 20 °C (ms)
Maximum Operating Rate (full load = 6 A)
Dropout
typical 10 ms
6 cycles/min.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
57
Relay and Timer Specifications
Cat. No. 700-HLT…2-Pole (Relay Output)
Environmental
Operating
–40…+60 °C
–40…+100 °C
Temperature
Altitude
Storage
2000 m (6560 ft)
Construction
Insulating Material
Enclosure
Molded High-Dielectric Material
Relay RT II — flux-proof, pollution degree 2 installation environment
AgNi 90/10 or AgNi 90/10 + Au
Contact Material
Terminal Markings on Socket
Certifications
In accordance with EN50 0005
cULus Listed (File No. E3125, Guide NRNT/NRNT7), CE Marked
UL 508, CSA C22.2 No. 14, EN 61810-1
Standards
Dimensions - 700-HL (2-pole)
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
92.8
(3.65)
87.7
(3.45)
14
(0.55)
14
(0.55)
75
(2.95)
75
(2.95)
Bulletin 700-HL Screw Terminal Design
Single Wire: 0.14 mm …2.5 mm (#26 AWG…14 AWG)
Bulletin 700-HL Spring Terminal Design
2
2
2
2
Single Wire: 0.2 mm …2.5 mm (#24 AWG…#14 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in)
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x 16 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in). Torque: 0.5 N•m (4.4 lb•in)
97.8
(3.85)
Bulletin 700-TBJ08_ 8-Way Jumper
58
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
199-DR1
A
B
C
D
Approx. Shipping Wt.
1.85 kg
(4.07lb)
(10/pkg)
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
3.68 kg
(8 lb)
(5/pkg)
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
199-DR4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
59
Relay and Timer Specifications
700-HLF Terminal Block Timing Relay
•
•
•
•
•
•
•
•
•
Relay and socket assembled modules for high-density applications
Screw terminal bases
6 A relay, choice of silver or gold contacts
SPDT (relay)
Four timing functions
Time range from 0.1 sec...6 hr
Built-in retainer clip and snap-in marker lever
Standard LED, reverse polarity protection, and surge protection
Externally replaceable relay modules
A2
A1
Wiring Diagram
18
15
16
Output Type
SPDT (1 C/O); Ith = 6A§
Recommended Tightening Torque
Wire Range
0.5 N•m max. (4.4 lb•in)
Screw Terminal: 0.14 mm2…2.5 mm2 (#26…#14 AWG)
Approvals
cULus, cURus, CE
Assembled Device
Input Voltage
Pkg. Quantity
Cat. No.(1)
24V AC/DC
10
700-HLF1U24
(1) For gold-plated contacts add an X after the catalog number listed.
Accessories - 700-HLF Relays
Terminal block timing relay bases are not sold separately.
Socket Input
Voltage
Photo
Description
Pkg. Quantity
Cat. No.
Replacement Relays
Order must be for 20 relays or multiples of 20.
20
24V AC/DC
700-TBR24(1)
Color
Red
20-Way Jumper
700-TBJ20R
700-TBJ20G
700-TBJ20B
Can be cut to required length. Ith = 36 A max per 20-way
1
Grey
Blue
jumper.
End Barrier
Used for visual inspection of groups, safe separation of
neighboring 700-HL modules that end with jumpers.
10
Black
Blank
700-HN177
Snap-in Marker
These snap-in markers have a 6 x 10 mm surface and snap into 100
the ejection lever for the relay.
1492-MC6X10
(1) For gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X.
60
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Function and Connection Diagrams - 700-HLF Relays
15
A1
U (A1/A2)
1 c/o (SPST)
t
R
LED
A2
A1
18 16
15
On-Delay
U (A1/A2)
1 c/o (SPST)
t
R
LED
A2
A1
18 16
One Shot
15
U (A1/A2)
1 c/o (SPST)
t
R
0.5s
LED
A2
A1
18 16
15
Pulse
U (A1/A2)
1 c/o (SPST)
t
t
t
R
LED
A2
18 16
Flasher
Specifications- 700-HLF Relays
Cat. No. 700-HLF… (Relay Output) (1)
Electrical Ratings
Pilot Duty Rating
B 300, R 300
Rated Thermal Current (I
)
1-Pole — 6 A
th
Rated Insulation Voltage(Ui)
250V IEC, 300V UL/CSA
1-Pole
Inductive
24VAC, 1-phase
30 A
30 A
5 A
3 A
120VAC, 1-
phase
Contacts
240VAC, 1-
phase
15 A
1.5 A
24VDC
120VDC
240VDC
1.0 A
0.2 A
0.1 A
Make, Break and
Continuous VDC
AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact
Inductive Load
DC-13 24V, 1 A N.O. and N.C. Contact
Min. Permissible Contact Ratings
12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
61
Relay and Timer Specifications
10% of Nominal
Voltage at AC,
5% of Nominal
Voltage at DC
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Must Dropout
Voltage:
Permissible Coil Voltage Variation
Power Consumption 10ꢀ
Pickup:
AC/DC
0.5VA
Design Specification/TestRequirements
Pole to Pole
(VRMS)
1000V
4000V
Dielectric Withstand Voltage
Contact to Coil
(VRMS)
Input Voltage
24V AC/DC
2 K
Impedance(Ohms)
Mechanical
Degree of Protection
IP20
7
Mechanical Life Operations
1 x 10
6 A Resistive: 100,000 min.
24V DC, 1 A Inductive: 200,000 min.
120V AC 1 A Inductive: 300,000 min.
Electrical Life Operations
Switching Frequency Operations (no-load)
Coil Voltages
10 cycles/sec
See Overview/Product Selection
On-Delay, One Shot, Pulse, and Flasher
0.1...3 s, 3...60 s, 1...20 min, and 0.3...6 hr
Timer Functions
Timer Settings
Timer Adjustments
Timer Accuracy
Min and Max adjustments with Potentionmeter
Repeatability 1%, Recovery Time < 50 ms, Setting Accuracy Full Range 5%
Coil Surge Protection
Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode
Environmental
Operating
Storage
–40…+55 °C (–40…+131 °F)
–40…+100°C (–40…+212°F)
2000 m (6560 ft)
Temperature
Altitude
Construction
Insulating Material
Enclosure
Molded High Dielectric Material
RelayIP67
Contact Material
Terminal Markings on Socket
Certifications
Silver Tin Ox, AgSnO or Silver with Gold Plating, AgSnO + Au
2
2
In accordance with EN50 0005
cULus Listed (File No. E3125, Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked
EN60947-4-1,EN60947-5-1,CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant
Standards
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.
62
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions- 700-HLF Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
76.0
(2.99)
6.20
(0.24)
88.0
(3.46)
700-HLF Screw Terminal Design
2
2
Single Wire: 0.14 mm …2.5 mm (#26 AWG…14 AWG)
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x 16 AWG)
Wire Type: Solid or stranded, copper only
Strip Length: 9 mm (11/32 in.). Torque: 0.5 N•m (4.4 lb•in)
12.5
6.2
(15/64)
1.0
(0.04)
50
(1-63/64)
(1/2)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
199-DR1
199-DR4
A
B
C
D
Approx. Shipping Wt.
1.85 kg (4.07lb) (10/pkg)
3.68 kg (8 lb) (5/pkg)
35 (1-3/8)
35 (1-3/8)
27 (1-1/16)
27 (1-1/16)
7.5 (19/64)
15 (19/32)
1.02 (1/64)
2.3 (3/32)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
63
Relay and Timer Specifications
700-HP Slim Line Relay
•
•
•
•
•
•
8 A contact ratings
DPDT/ (2 c/o) contacts
Plug-in PIN style (PCB) terminals (5 mm pinning)
Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts
Available with mechanically linked contacts (Type B)
Safety Control Relay Version (700-HPS)
Wiring Diagrams
U.S./Canada
Contact
Rating
Coil
Pkg.
Photo
Description
Cat. No.
Voltage Qty.
International
6V AC
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
700-HPX2A06
700-HPX2A12
700-HPX2A24
700-HPX2A1
700-HPX2A2
700-HPX2Z06
700-HPX2Z12
700-HPX2Z24
700-HPX2Z48
700-HPX2Z1
700-HP32A06
700-HP32A12
700-HP32A24
700-HP32A1
700-HP32A2
700-HP32Z06
700-HP32Z12
700-HP32Z24
700-HP32Z48
700-HP32Z1
12V AC
24V AC
120V AC
240V AC
6V DC
DPDT
2-Pole
2 Form C
AgNi + Au
Gold Plated
Contacts
12V DC
24V DC
48V DC
110V DC
6V AC
8 A
12V AC
24V AC
120V AC
240V AC
6V DC
DPDT
2-Pole
2 Form C
AgNi Contacts
12V DC
24V DC
48V DC
110V DC
Sockets
700-HN123
700-HN123
64
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HPS Safety Control Relay
Wiring Diagrams
U.S./Canada
Contact
Rating
Coil
Voltage Qty.
Pkg.
Photo
Description
Cat. No.
International
6V DC 10
700-HPSXZ06
700-HPSXZ12
700-HPSXZ24
700-HPSXZ48
700-HPSXZ60
700-HPSXZ1
700-HPSXZ01
700-HPS2Z06
700-HPS2Z12
700-HPS2Z24
700-HPS2Z48
700-HPS2Z60
700-HPS2Z1
700-HPS2Z01
12V DC 10
24V DC 10
48V DC 10
60V DC 10
110V DC 10
125V DC 10
DPDT 2-Pole
2 Form C AgNi +
Au Gold Plated
Mechanically Linked
Contacts
8 A
6V DC
10
12V DC 10
24V DC 10
48V DC 10
60V DC 10
110V DC 10
125V DC 10
DPDT 2-Pole
2 Form C AgNi
Mechanically Linked
Contacts
700-HPS DPDT
Sockets
700-HN123
700-HN123
Accessories - 700-HP, -HPS
Pkg.
Qty.
Photo
Description
Cat. No.
Diode Surge Suppressor
10
10
10
10
10
700-ADR
Voltage Range: 6…220V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
Voltage Range: 6…24V DC used with 700-HN123 socket
700-ADL1R
700-ADL2R
700-ADL3R
700-AV1R
Diode with LED Surge Suppressor
Voltage Range: 28…60V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
Voltage Range: 110…220V DC used with 700-HN123 socket
Diode with LED Surge Suppressor
Voltage Range: 6…24V AC used with 700-HN123 socket
Varistor with LED Surge Suppressor
Voltage Range: 110…240V AC
used with 700-HN123 socket
10
700-AV3R
RC Surge Suppressor
10
10
700-AR1
700-AR2
Voltage Range: 6…24V AC/DC used with 700-HN123 socket
RC Surge Suppressor
Voltage Range: 110…240V AC/DC used with 700-HN123 socket
Timing Module
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets
that accept plug-in accessory modules.
700-AT3
Timing Module
On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets
that accept plug-in accessory modules.
1
700-AT3A1
700-AT3A2
Timing Module
On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets
that accept plug-in accessory modules.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
65
Relay and Timer Specifications
Pkg.
Qty.
Photo
Description
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting
10
1
700-HN123
8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.
Red
Gray
Blue
700-TBJ20R
700-TBJ20G
700-TBJ20B
8-Way Jumper can be cut to required length. Rated 10 A – 250V
Plastic Retainer and Ejection Lever
For use with the 700-HN123 sockets
10
10
10
700-HN119
700-HN230
700-HN232
Built-in ability to accept 1492 snap-in markers
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting
8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.
Plastic Retainer and Ejection Lever
For use with the 700-HN230 sockets
Built-in ability to accept 1492 snap-in markers
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
5
5
5
5
5
1492-MS5X12
1492-MS6X9
1492-MS6X12
1492-MS8X9
1492-MS8X12
Relay Identification Snap-in Markers
Note - These markers can only be used when the Plastic Retainer and Ejection Lever accessory (part # 700-
HN119) is used because the markers snap into the Ejection Lever (and not into the relay itself).
100
1492-MP-Blank
700-N40
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13
sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky
backing for easy placement on relays.
10
700-N41
Socket, and Retainer Clip Reference
Relay Type
700-HPX2
700-HP32
700-HPS2
700-HPSX
Socket Cat. No.
700-HN123
700-HN123
700-HN123
700-HN123
Retainer Clip Cat. No.
700-HN119
700-HN119
700-HN119
700-HN119
66
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
(1)
Specifications - 700-HP Relays
Cat. No. 700-HP…
Cat. No. 700-HP3…, 700-HPX
AC15@ 500V AC
Cat. No. 700-HPS…
C300
B300
VAC
VDC
1/3 Hp @ 240V AC
1/6 Hp @ 120V AC
1/2 Hp @ 240V AC
1/3 Hp @ 120V AC
Inductive
AC-1 2000VA
R300
—
Contacts
DC-1: 8A @ 30VDC
DC-1: 0.3A @ 110V DC
DC-1:0.1A @ 220V DC
DC-1: 0.65A @ 110V DC
DC-1:0.2A @ 220V DC
AC
DC
8 A @ 277V AC (per pole)
8 A @ 30V DC(per pole)
Resistive
700-HP32: 300mW (5V, 5 mA)
700-HPX2: 50mW (5V,5 mA)
700-HPS2: 500 mW (10V, 10 mA)
700-HPSX: 50 mW (5V, 5 mA)
Minimum Load
Nominal Coil Power (AC/DC)
OperatingRange(AC/DC)
1.2 VA / 0.65 W
0.7 W
80...110% / 73...150%
Nominal Voltage
75...120%
Nominal Voltage DC
Holding Voltage (AC/DC)
Must Drop Out Voltage (AC/DC)
Insulation Voltage
80/40%NominalVoltage
20/10%NominalVoltage
40% Nominal Voltage DC
10% Nominal Voltage DC
250VAC
700-HPS
2000V AC
4000V AC
DesignSpecification/TestRequirements
700-HP3, 700-HPX
Pole to Pole (VRMS)
Dielectric Withstand Voltage
for 1 minute
Contact to Coil (VRMS)
Mechanical
Degree of Protection
OpenType (Sockets)
6
6
10 x 10 (AC Coils), 20 x 10
(DCcoils)
6
Mechanical lifecycles
10 x 10 (DC Coils)
Switching Frequency Operations
Coil Voltages
1800/hr (no load)
900/hr (no load)
10
See Overview/Product Selection
Operating Time at Nominal
Voltage
at 20 °C (ms)
Pickup
12
Dropout
4
Maximum Operating Rate
16 Ops/s (full load)
8 Ops/s (full load)
Enclosure
Fragility
5 G
2.5 G
Vibration
Endurance
Fragility
50 G
Shock
15 G
Max. Socket Torque
0.5 N•m(4.4 lb•in)
Environmental
Operating
Storage
–40…+85 °C (–40…+185 °F)
–45…+100 °C (–49…+212 °F)
–40…+70 °C (–40…+158 °F)
–50…+80 °C (–40…+176 °F)
Temperature
Altitude
2000 m (6560 ft)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
67
Relay and Timer Specifications
(1)
Specifications - 700-HP Relays
Construction
Insulating Material
Enclosure
Molded High-Dielectric Material
Transparent Dust Cover Red Transparent Dust Cover
Silver Nickel, (AgNi) (700-HP32 and 700-HPS2), Silver Nickel + Gold Plating
(AgNi + Au) (700-HPX2 and 700-HPSX)
Contact Material
Terminal Markings on Socket
In accordance with EN50 0005
2-Pole
Sockets
700-HN123
Approvals
cURusRecognized(FileNo. E3125, GuideNLDX2/NLDX8), cULus Listed when
used with 700-HN123 socket (File No. E3125, Guide NLDX/NLDC7), CSA
Certified (files 229473), CE Marked, LR Certified (700-HP), IMQ & TÜV
Certified (700- HPS)
Certifications
Standards
UL 508, CSA 22.2 No. 14, EN 61810-1, EN 50205 (700-HPS)
(1) The inrush VA equals 1.5 times the sealed VA.
68
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HP Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
29.0
(1.14)
12.4
(0.49)
25.0
(0.98)
700-HP Relay
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(39-3/8)
(0.3)
Cat. No. 700-HN123
2
Single Wire: 0.2.....2.5 mm (#24.....14 AWG)
2
Double Wire: 2 X 0.2.....2 X 2.5 mm (#2 X 24....2 X 14 AWG)
Wire Type: solid or stranded, copper only
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
Cat. No.
199-DR1
A
B
C
D
Approx. Shipping Wt.
1.85 kg
(4.07lb)
(10/pkg)
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
3.68 kg
(8 lb)
(5/pkg)
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
199-DR4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
69
Relay and Timer Specifications
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
60.9
(2.40)
17.5
(0.69)
21
6
11
3
17.5
(0.69)
24
5
14
4
21.6
(0.85)
12
2
22
7
Ø 3.2
(0.12)
Use M3 Screws
78.6
(3.09)
35.4
(1.39)
8 (+)
A1
1 (-)
A2
21.6
(0.85)
4.0
(0.16)
15.8
(0.62)
Cat. No. 700-HN123
2
Single Wire: 0.2.....2.5 mm (#24.....14 AWG)
2
Double Wire: 2 X 0.2.....2 X 2.5 mm (#2 X 24....2 X 14 AWG)
Wire Type: solid or stranded, copper only
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
Cat. No. 700-HN230
Min wire size: 0.5mm2 (21 AWG.)
Max wire size: 2 x 1.5 and 1 x 2.5 mm2 (2 x18 / 1 x 14 AWG)
Wire Type: solid or stranded, copper only
Stripe Length: 8mm (10/32 in.)
70
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HJ Magnetic Latching Relay
•
•
•
•
•
10 A Contact Rating
SPDT
DPDT Single Coil
DPDT Dual Coil
Blade Style Quick Connect Terminals
Wiring Diagrams
AC(2)
Contact
Rating
Photo
Description
Coil Voltage Cat. No.
DC(3)
24V AC
700-HJ36A24
700-HJ36A1
120V AC
SPDT
1-Pole
1 Form C
AgCdO Contacts
(Single Coil
AC or DC)
10 A
24V DC
700-HJ36Z24
Sockets
700-HN153
700-HN154
24V AC
700-HJ32A24
700-HJ32A1
700-HJ32A2
120V AC
240V AC
DPDT
2-Pole
2 Form C
AgCdO Contacts
(Single Coil
AC or DC)
10 A
12V DC
24V DC
700-HJ32Z12
700-HJ32Z24
Sockets
700-HN153
700-HN154
DPDT
2-Pole
2 Form C
AgCdO Contacts
10 A
DC Only
24V DC
700-HJD32Z24
(Dual Coil(1)
700-HN153 or
700-HN154
Sockets
(1) Available only in DC Coil with DPDT contacts.
(2) AC Relays include internal diodes.
(3) For DC operation, polarity must be observed.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
71
Relay and Timer Specifications
Accessories-700-HJ Relays
Photo
Description
Pkg. Qty.
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting. Guarded Terminal Construction
11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the
ability to use optional plug-in modules ( 700-A__ accessories, LED, surge suppression, timing modules).
10
700-HN153
Screw Terminal Base Socket — Panel or DIN Rail Mounting. Open Style Construction
10
10
700-HN154
199-DR1
11-blade for use with 700-HB relays.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
Retainer Clip
For Cat. Nos. 700-HN153 and -HN154 Sockets with 700-HJ Relays
Secures relay in socket. Order must be for 10 clips or multiples of 10.
10
10
700-HN159
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are
peel-off with sticky backing for easy placement on relays.
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10
relays.
Socket and Retainer Clip Reference
Relay Type
Socket Cat. No.
700-HN153
Retainer Clip Cat. No.
700-HN159
700-HJ
700-HN154
700-HN159
Specifications - 700-HJ Relays
Attribute
700-HJ
Electrical Ratings
Pilot Duty Rating
—
Rated Thermal Current (I
)
10 A
th
250VIEC,
300V UL/CSA
Rated Insulation Voltage(Ui)
Make
Break
Hp
Inductive
Contacts
120VAC
240VAC
30 A
15 A
3 A
1.5 A
1/4
1/3
DC
24V DC, 10 A
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Permissible Coil VoltageVariation
72
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HJ Relays
Single
AC Coil
Single
DC Coil
Dual
DC Coil
1.44 VA
1.44 VA
Inrush
Sealed
AC Coils
DC Coils
—
—
CoilConsumption 10%
12V 1.63 W
24V 1.67 W
—
1.2 W
DesignSpecification/TestRequirements
Pole-to-Pole
1500V AC
1500V AC
1500V AC
Dielectric Withstand Voltage
Degree of Protection
Contact-to-Pole
Contact-to-Frame
Mechanical
Open Type
(Guarded Terminal Sockets)
6
Mechanical Life Operations
Switching Frequency Operations
Coil Voltages
10 x 10
1800/HR
See Product Selection
Pickup
Dropout
25 ms
25 ms
Operating Time at Nominal Voltage at 20 °C
Maximum Operating Rate
—
Environmental
Construction
–45…+50 °C
Operating
Storage
(–49…+122 °F)
Temperature
Altitude
–45…+100 °C
(–49…+212 °F)
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings on Socket
Silver Cad. Ox.
In accordance with EN50 0005
11-Blade Socket
Cat. No. 700-HN153
Cat. No. 700-HN154
Sockets
Certifications
Standards
CSA Certified, File LR700026, UL Recognized, File E3125, Guide NLDX 2
UL 508, CSA 22.2 No. 14, EN/IEC 60947-4-1, -5-1
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
73
Relay and Timer Specifications
Dimensions - 700-HJ Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
700-HJ Relay
Cat. No. 700-HN153
Wire Size: 2 x 2.5 mm
2
Single Wire – Up to #12 AWG
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in
Cat. No. 700-HN154
Wire Size: 2 x 2.5 mm
2
Single Wire – Up to #12 AWG
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Cat. No.
199-DR1
199-DR4
A
B
C
D
Approx. Shipping Wt.
1.85 kg (4.07lb) (10/pkg)
3.68 kg (8 lb) (5/pkg)
35 (1-3/8)
35 (1-3/8)
27 (1-1/16)
27 (1-1/16)
7.5 (19/64)
15 (19/32)
1.02 (1/64)
2.3 (3/32)
74
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HG Power Relay
•
•
•
•
•
40 A Contact Ratings
SPST-NO-DM, SPDT, DPST-NO, DPDT
Panel Mounted
Options: Magnetic Blowout for High DC Loads, Auxiliary Snap Action Switch
Screw Terminals #6-32 for Coil, #8-32 for Contacts
Description
Contact Ratings
Wiring Diagrams
Coil Voltage
24V AC
Cat. No.(1)
700-HG45A24
700-HG45A1
700-HG45A2
700-HG45A27
700-HG45A4
700-HG45Z12
700-HG45Z24
700-HG45Z48
700-HG45Z1
700-HG46A24
700-HG46A1
700-HG46A2
700-HG46Z12
700-HG46Z24
700-HG46Z48
700-HG46Z1
700-HG47A24
700-HG47A1
700-HG47A2
700-HG47A4
700-HG47Z12
700-HG47Z24
700-HG47Z48
700-HG47Z1
700-HG42A24
700-HG42A1
700-HG42A2
700-HG42A27
700-HG42Z12
700-HG42Z24
700-HG42Z48
700-HG42Z1
700-HG42Z2
700-HG42Z25
120V AC
240V AC
277V AC
480V AC
12V DC
SPST-NO-DM
1 Form X
40 A
(A600)
AgCdO Contacts
24V DC
48V DC
110V DC
24V AC
120V AC
240V AC
12V DC
SPDT
1-pole
1 Form C
AgCdO Contacts
40 A
(A600)
24V DC
48V DC
110V DC
24V AC
120V AC
240V AC
480V AC
12V DC
DPST-NO
2-pole
40 A
(A600)
2 Form A
AgCdO Contacts
24V DC
48V DC
110V DC
24V AC
120V AC
240V AC
277 AC
DPDT
2-pole
2 Form C
AgCdO Contacts
12V DC
40 A
(A600)
24V DC
48V DC
110V DC
220V DC
250V DC
(1) Auxiliary Snap Switch Option: Add suffix (-5) to the selected 700-HG relay Cat. No., except for the 220V DC add (-5L).
Magnetic Blowout Option: Add suffix (-6) to the selected 700-HG relay Cat. No. (suppresses the arc when switching DC loads – ratings listed below).
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
75
Relay and Timer Specifications
Accessories - 700-HG Relays
Pkg.
Qty.
Photo
Description
Cat. No.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. 10
Tags are peel-off with sticky backing for easy placement on relays.
700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
700-N41
Type 1 Enclosure For use with any of the listed relays. Knockouts for 1/2 in. and 3/4 in. conduit
connections. The enclosure exceeds the minimum clearances required by U.S. standards, resulting
in generous wiring spaces.
1
700-HN120
Auxiliary Snap Action Switch
Contact
Material
Silver Cad. Ox.
Rating
Dielectric Withstand V (1 Min.)
SPDT (1 Form C)
10 A at 120 or 240 Resistive
1500V AC RMS Contact to Frame
76
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HG Relays
Attribute
700-HG
Electrical Ratings
Pilot Duty Rating (1)
A600
40 A
Rated Thermal Current (I
)
th
Rated Insulation Voltage(Ui)
600V UL
Contact Ratings: AC Ratings SPST-NO-DM
Contact Ratings: AC Ratings SPDT, DPST - NO and DPDT
Inductive
Resistive -
Make/Break
and
Inductive
Resistive -
Make/Break
and
Volts
HP Volts
HP (2)
Make
Break
Continuous
Make
Break
Continuous
Continuous
Continuous
120
60 A
30 A
15 A
12 A
6 A
3 A
10 A
10 A
10 A
10 A
40 A
40 A
12 A
10 A
120
60 A
30 A
15 A
15 A
6 A
3 A
10 A
10 A
10 A
10 A
40 A
40 A
5 A
2
1 - 1/2
1 - 1/2
240
240
480V
600V
1.5 A
1.2 A
480
1.5 A
1.2 A
2
600
5 A
DC Ratings: Without Magnetic Blowouts - 28V 40 A - Make, Break and Continuous Est Drop 125V 1.2...3 A
SPST - NO -
DC Ratings: With Magnetic Blowouts:
DM
SPDT, DPST - NO and DPDT
110V
220V
325V
500V
20 A
8 A
4 A
2 A
10 A
4 A
2 A
Make, Break, and Continuous
—
80…100% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Permissible Coil Voltage Variation
50 HZ
60 HZ
Inrush
Sealed
13 VA
10 VA
16 VA
11 VA
AC Coils
Coil Consumption 10%
DC Coils
2.0 W
Design Specification/Test Requirements
2200V AC
Pole-to-Pole
ContacttoPole
Contact to Frame
Dielectric Withstand
Voltage
2200V
2200V AC
Mechanical
Degree of Protection
Open Type
6
Mechanical Life Operations
5 x 10
Switching Frequency Operations
Coil Voltage
1600/Hr
See Overview/Product Selection
Operating Time at Nominal
Voltage at 20 °C (68 °F)
Pickup
Dropout
40 ms
35 ms
Maximum Operating Rate
—
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
77
Relay and Timer Specifications
Specifications - 700-HG Relays
Environmental
Construction
Operating
Storage
30…+55 °C (-22...+149 °F)
-30…+65 °C (-22...+149 °F)
2000 m (6560 ft)
Temperature
Altitude
Molded Thermo
Insulating Material
Setting Plastic
Enclosure
—
Contact Material
Terminal Markings on Socket
Sockets
Silver Cadmium Oxide
—
—
Certifications
Standards
CSA Certified, File 225674, UL Listed, File E3125, Guide NLDX, CE Marked
UL 508, CSA 22.2 No. 14, EN/IEC 60947-1, -5-1
(1) NEMA Rating Chart is on page 19 of publication 700-SG003B-EN-P.
(2) For DPDT only: 2 Hp Switching 2 Poles, 200...600V AV, 50/60 Hz.
78
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HG Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
700-HG Relay, SPST-NO-DM
700-HG Relay
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
79
Relay and Timer Specifications
700-HHF Flange Mount Power Relay
•
•
•
Flange-Mounted
Blade Style 0.250 x 0.032 Quick Connect/Solder (no socket) Terminals
Solder Terminals (no socket)
Wiring Diagrams
Description
Contact Rating
Coil Voltage
Cat. No.
U.S./Canada
International
120V AC
700-HHF45A1
SPST-NO-DM
1 Form X
AgCdO Contacts
30 A
(A600)
24V DC
700-HHF45Z24
24V AC
120V AC
240V AC
12V DC
700-HHF62A24
700-HHF62A1
700-HHF62A2
700-HHF62Z12
DPDT
2-Pole
25 A
(B600)
2 Form C
AgCdO Contacts
24V DC
700-HHF62Z24
3PDT
3-Pole
20 A
(B300)
120V AC
700-HHF73A1
3 Form C
AgCdO Contacts
Specifications - 700-HHF Relays
Attribute
700-HHF…
Electrical Ratings
SPST-NO-DM
NEMAA600
NEMA B600
NEMA B300
Pilot Duty Rating (1)
DPDT
3PDT
Rated Thermal Current (I
)
SPST-NO-DM 30 A, DPDT 25A, 3PDT 20 A
250V IEC-300V UL/CSA
th
Rated Insulation Voltage(Ui)
Inductive
SPST-NO-DM
Hp
DPDT
Hp
3PDT
Hp
Contacts
120VAC
240VAC
DC
60 A
30 A
6 A
3.0 A
28V DC, 30 A
1
30 A
15 A
3 A
1.5 A
1
30 A
15 A
3 A
1.5 A
—
1/2
1-1/2
1-1/2
—
28V DC, 13 A
80
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HHF Relays
Attribute
700-HHF…
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
DPDT
Permissible Coil Voltage Variation
SPST-NO-DM
50 Hz
3PDT
50 Hz
60 Hz
50 Hz
60 Hz
6.3 VA
4.2 VA
60 Hz
Inrush
Sealed
7.2 VA
6.3 VA
4.2 VA
7.2 VA
4.8 VA
7.2 VA
4.8 VA
6.3 VA
4.2 VA
Coil
Consumption
10%
AC Coils
DC Coils
4.8 VA
1.4 W
25%of VA
10% of W
Max. Allowable Leakage
Design Specification/TestRequirements
Pole-to-Pole
Dielectric Withstand
Contact-to-Pole
Voltage
2200V AC
2200V AC
1600VAC
Contact-to-Frame
Mechanical
6
Mechanical Life Operations
Switching Frequency Operations
Coil Voltages
5 x 10
3600/Hr
See Overview/Product Selection
Pickup
20 ms
15 ms
Operating Time at Nominal
Voltage at 20 °C
Dropout
Maximum Operating Rate
4 Ops/s.
Environmental
–30…+50 °C
(–22…+122 °F)
–30…+100 °C
(–22…+212 °F)
2000 m (6560 ft)
Operating
Temperature
Storage
Altitude
Construction
Insulating Material
Enclosure
Molded High Dielectric Material
Transparent Dust Cover
Contact Material
Terminal Markings
Sockets
Silver Cadmium Oxide
In accordance with EN50 0005
(2)
Certifications
cURus Recognized, File E3125,Guide NLDX2/NLDX8, CE Marked
UL 508, CSA 22.2 No.14, EN/IEC 60947-1, -5-1
Standards
(1) See NEMA Ratings and Test Values on page 5.
(2) 700-HHF relay wiring and terminals are the quick connect / solder type 6.35 x 0.82 mm (0.250 x 0.032 in) termination.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
81
Relay and Timer Specifications
Dimensions - 700-HHF Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
35.7
(1-13/32)
3.97
(5/32)
63.5
(2-1/2)
38.9
(1-17/32)
73.8
(2-29/32)
700-HHF Relay
82
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HTA Alternating Relay
•
•
•
•
Alternating Relay
Rugged Pin Style Socket Mounting
10 A, SPDT, DPDT, and Cross Wired
Excellent for Pump Panel Applications
700
–
HTA
2
A12
7
a
b
c
d
e
Catalog Number Explanation - 700-HTA Relays
a
b
c
d
e
-
Bulletin Number
Relay Type
Model Type
Coil Voltage
Gold Plated Contacts Option
A12 - 12V AC 50/60 Hz
A24 - 24V AC 50/60 Hz
A1 - 120V AC 50/60 Hz
A2 - 240V AC 50/60 Hz
1 - SPDT
2 - DPDT
3 -Cross-Wired
Blank - Without switch
7 - With switch
HTA - Tube Base
Alternating Relay
700
Alternating Relays with Pin-Style Terminations
Wiring Diagrams
U.S./Canada
700-HTA
Alternating Relay
International
SPDT Form C Contact
SPDT
DPDT 2 Form C Contact
DPDT
Cross-Wired DPDT 2 Form C
Contacts
Cross-Wired
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
83
Relay and Timer Specifications
Accessories - 700-HTA Relays
Photo
Description
Pkg. Qty. Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin
10
10
700-HN100
700-HN125
for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use
with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten. No retainer clip required.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-
10
10
700-HN101
700-HN126
pin for use with 700-HTA2A alternating relays. Order in multiples of 10.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style Terminal
Construction. 11-pin for use with 700-HTA2A alternating relays. Order in multiples of 10. No retainer clip required.
DIN (#3) symmetrical hat rail
10
10
199-DR1
35 x 7.5 x 1 m
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing Relays, and 700-HTA
Alternating Relays
Secures relay in socket. Order must be for 10 clips or multiples of 10.
700-HN110
700-N40
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41
84
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HTA Relays
Attribute
700-HTA
ElectricalRatings
Pilot Duty Rating (1)
NEMA B300 AC 15
10 A
Rated Thermal Current (I
)
th
Rated Insulation Voltage(Ui)
250V IEC, 300V UL/CSA
Inductive
Make
Break
HP
Contacts
120VAC
30 A
15 A
10 A
3 A
1.5 A
10 A
1/3
1/2
—
240VAC
Resistive 30V DC
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
Permissible Coil Voltage Variation
Power Consumption 10%
24VAC
2 VA
4 VA
4 VA
AC
120VAC
240VAC
Design Specification/TestRequirements
Pole-to-Pole, same circuit
1000V AC
2000V AC
(VRMS)
Dielectric Withstand Voltage
Pole-to-Pole, different circuits
(VRMS)
Contact-to-Coil (VRMS)
2000V AC
100,000 minimum
1800/hr
Electrical Life Operations
Switching Frequency Operations
Coil Voltages
See product selection
Mechanical
Degree of Protection
Open Type (Guarded Terminal Sockets)
6
Mechanical Life Operations
Switching Frequency Operations
10 x 10
18,000/hr
0.05 sec
Start-up Time (max. time from power application until unit is timing)
Max. Function Time (max. time power can drop out and unit continues timing)
Min. Cycle Time
0.01 sec
100 ms on release of the control switch
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
85
Relay and Timer Specifications
Specifications - 700-HTA Relays
Attribute
700-HTA
Environmental
Construction
–28…+65 °C (50 °C max., 240V AC coil)
(–18…+149 °F) (122 °F max., 240V AC coil)
Operating
Storage
Temperature
Altitude
–55…+85 °C
(–67…+185 °F)
2000 m (6560 ft)
Insulating Material
Enclosure
Molded High Dielectric Material
Impact Resistant Dust Cover
Silver Tin Oxide
Contact Material
Terminal Markings on Socket
In accordance with EN50 005
8- or 11-Pin Socket 700-HN100, -HN125
700-HN101, -HN126
Sockets
CSA Certified, File 223833, UL Recognized (File E3125 Guide NLDX2/NLDX8),
cULus Listed with 700-HN100, 700-HN101, 700-HN125, and 700-HN126
Sockets (File No. E3125 Guide NLDX/NLDX7), CE-Marked
(per EU Low Voltage Directive)
Certifications
Standards
EN 61812-1, CSA 22.2 No. 14, UL 508
(1) See NEMA Ratings and Test Values on page 5.
86
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Trigger Signal Cat. Nos. 700-HTA
Contact closure provides signal to timer. The 700-HTA alternating relay generates a low energy signal. For optimum reliability, use contacts
designed for low energy switching (10V, 1 mA) (Example: Bul. 800F-X_V, 800T-X_V). No external voltage can be connected to the contact signal.
Load Diagrams - 700-HTA Relays
Cross Wired Lead/Lag/Lag/lead Sequence
Common Input/Output SPDT/DPDT
Lead
Lag
B1
Load A
Load B
LED A
LED B
Load A
Load B
LED A
LED B
Power
Power
Socket
Pinout Map
DPDT
Socket
Pinout Map
SPDT
Socket
Pinout Map
Cross-Wired
Relay
A1
A2
Socket
4
8
Relay
A1
A2
Socket
4
3
Relay
A1
A2
Socket
3
6
Note: pin out in wiring diagram may not match actual printed
socket see pinout map for wiring up the power source
Note: pin out in wiring diagram may not match actual printed
socket see pinout map for wiring up the power source
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
87
Relay and Timer Specifications
Dimensions - 700-HTA Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
79
(3-7/64)
74
(2-29/32)
60
(2-23/64)
43
(1-11/16)
24.6
(31/32)
40.1
(1-37/64)
20.8
(53/64)
30.0
(1-3/16)
26
(1-1/32)
24.9
(63/64)
54.9
(2-5/32)
65.0
(2-35/64)
51.1
(2-1/64)
4.2
(5/32)
38.0
(1-1/2)
33.0
(1-19/64)
#4–40
M3
14.7
(37/64)
Cat. No. 700-HN100
Cat. No. 700-HN125
Wire Size: 2 x 2.5 mm
2
Panel Mounting
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)
(Either Solid or Stranded)
Single Wire — Up to #12 AWG
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG… #2 – 20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in) — Torque: 0.8 N•m (7 lb•in)
59.2
(2-1/3)
24.6
(31/32)
20.8
(53/64)
26
(1-1/32)
7.9
(0.31)
30
(1-3/16)
26.9
(1.06)
54.9
(2-5/32)
65.0
(2-35/64)
51.1
(2-1/64)
4.2
(5/32)
38.0
(1-1/2)
#4-40
M3
52.3
(2.06)
Cat. No. 700-HN101
Cat. No. 700-HN126
Wire Size: 2 x 2.5 mm
2
Panel Mounting
2
Double Wire – 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)
(Either Solid or Stranded)
Single Wire — Up to 12 AWG
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)
Strip Length: 9 mm (3/8 in) — Torque: 0.8 N•m (7 lb•in)
88
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
General Purpose Electronic Timers and Counters
Product Overview
700-HR52, -HRP,
-HRS, -HRT, -HRV
Bulletin No.
Type
700-FE
700-FS
700-HRM/-HRC
700-HRF
DIN Rail Timer
DIN Rail Timer
Multifunction Timer
On-Delay Timer
Twin Timer
•
•
•
Dial timing relays
5 A contact rating
Multiple programmable
timing ranges
•
•
•
Only 22.5 mm wide
8 A contact rating
Multifunction or single
function
•
•
•
Dial timing relays
5 A contact rating
Multiple programmable
timing ranges
•
•
•
Only 17.5 mm wide
5 A contact rating
Multifunction or single
function
No additional socket
required
•
Tube base pin style
terminals
•
Independent ON and
OFF settings
14 time ranges
8-pin models available
Dial timing relays
UL508
•
No additional socket
required
•
Tube base pin-style
terminals
•
•
Multi-voltage inputs
Timed contacts and
instantaneous contacts
Transistor outputs
Single function and
multi-function
•
•
•
•
Features
•
•
Optional:
•
•
Multi-voltage inputs
Timed contacts and
instantaneous contacts
Transistor outputs
Single function and
multi-function
Star-delta timing
function
•
•
•
•
•
True off-delay timing
function
•
•
Hazardous location
certification
•
7 different operating
modes
Control Outputs:
Time Limit
Instantaneous
SPDT or DPDT or
2 N.O. + 1 common
DPDT Timed, Transistor
DPDT Timed, Transistor
1 N.O. or SPDT timed
DPDT Timed
SPDTTimed/Instantaneous SPDTTimed/Instantaneous
On-Delay
Off-Delay
One Shot
Repeat Cycle Off Start
Repeat Cycle On Start
Signal On/Off-Delay
On-Delay One Shot
On-delay
Off-delay
One shot
Repeat Cycle Off Start
Repeat Cycle On Start
Operation Modes:
11 timing modes
0.05 s…60 hr
On-Delay
Repeat cycle-pulse
Fleeting off-delay
Pulse converter
Time Range
0.05 s…10 hr
0.05 s…300 h
0.05 s…300 h
0.05 s…300 h
24V AC/DC
12…48V DC
24…48V AC
100…240V AC
100…125V DC
12…48V DC
24…48V AC
100…240V AC
100…125V DC
12V DC
12V DC
24V…48V DC
24V…240V AC
110…240V AC
24…48V AC/DC
24…240V AC
24V AC/DC
Supply Voltage
48…125V DC
100…240V AC
Contact Rating at 120V
AC
5 A
8 A
5 A
5 A
5 A
Certifications
Socket Cat. No(s).
Page
CE, cULus
CE, cULus
cURus, CE, C-Tick
cURus, CE, C-Tick
cURus, CE, C-Tick
700-HN100 OR 700-HN101 700-HN100
700-HN125 OR 700-HN126 700-HN125
700-HN100
700-HN125
DIN Rail or panel mount
92
DIN Rail or panel mount
96
116
117
117
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
89
Relay and Timer Specifications
Bulletin No.
Type
700-HRY
Star-Delta Timer
700-HRQ
700-HNC
700-HNK
True Off-Delay Timer
Miniature Timer
Ultra-Slim Timer
•
•
Ultra-slim timing relay
Four different operating
modes
•
•
•
A wide star-time range
(up to 120 s)
•
•
•
Dial timing relays
Long power Off-delay times
11-pin and 8-pin models are
available
•
•
•
Four different operating modes
DIN Rail mount with socket
Pin configuration same as 700-HC
relay
•
•
Three operating voltages
DIN Rail mount with
socket
Features
Star-delta transfer time range
(up to 0.5 s)
UL Recognized
•
UL Recognized
•
Pin configuration same as
700-HK relay
Control Outputs:
Time Limit
Instantaneous
SPST (Star, Delta) Timed
SPST - NO Instantaneous
DPDT Timed
4PDT
SPDT, DPST-NO
On-Delay
On-Delay
True OFF-delay Timer
True OFF-delay Timer w/reset
One Shot
One Shot
Operation Modes: Star-Delta
Repeat Cycle Off Start
Repeat Cycle On Start
Repeat Cycle Off Start
Repeat Cycle On Start
Time Range
0.5 s…120 s
0.05 s…12 min
0.1 s…10 h
0.1 s…10 h
48V DC
12V DC
12V DC
24V DC
24V AC
100…120V AC
200…240V AC
24V AC/DC
24V AC/DC
Supply Voltage
100…240V AC
100…125V DC
48…125V DC
100…240V AC
Contact Rating at
120V AC
5 A
5 A
5 A
5 A
Certifications
Socket Cat. No(s).
Page
cURus, CE, C-Tick
cURus, CE, C-Tick
cURus, CSA, CE, C-Tick
cURus, CE, ACA
700-HN100
700-HN125
700-HN100 OR 700-HN101
700-HN125 OR 700-HN126
700-HN103
700-HN128
700-HN121
700-HN122
117
118
103
109
90
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Bulletin No.
700-HT
700-HV
700-HX
Type
Tube Base Timing Relay
Repeat-Cycle Timing Relay
Digital Timer
•
•
•
•
•
Digital timer
5 A contact rating
Negative transmissive LCD display
10 functions or modes
•
•
•
Pin-style terminals
Single range or fixed timers
Available as ON- or OFF-Delays
•
•
•
Pin-style terminals
Single-range timer
Repeat cycle
Features
Environmentally friendly—flash memory, no
battery
•
•
•
NEMA B300 rated
NEMA 4/IP66
DIN Rail or panel mount capable
Control Outputs:
Time Limit Instantaneous
DPDT
DPDT
SPDT
Signal On-Delay 1 and 2
Signal Off-Delay
One Shot
On-Delay
Off-Delay
Repeat Cycle Off Start
Repeat Cycle On Start
Signal On/Off-Delay
Power On-Delay 1 and 2
Twin Timer Cumulative
Timing Operation Modes:
Repeat Cycle
Time Range
0.1 s…30 min.
0.1 s…30 min.
0.05 s…300 h
12V DC
24V DC
24V AC
120V AC
240V AC
24V DC
24V AC
120V AC
240V AC
12…24V DC
24V AC
100…240V AC
Supply Voltage
Contact Rating at 120V AC
Certifications
10 A
10 A
5 A
UR, UL, CSA, CE
UR, UL, CSA, CE
cURus, CE, C-Tick
700-HN100 OR 700-HN101
700-HN125 OR 700-HN126
700-HN100
700-HN125
700-HN100
700-HN125
Socket Cat. No(s).
Page
128
133
138
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
91
Relay and Timer Specifications
700-FE Economy Timing Relay
•
•
•
•
•
•
Adjustable function and timing range timing relays
DIN Rail mounted without cost of socket
17.5 mm wide, multi-function or single function
Available as 1 N.O. or SPDT contact output, 5 A
Timing ranges from 0.05 s…10.0 hr
Coil surge protection
Multi-Function
This device offers you the flexibility of selecting one of 4 single timing functions.
Operating Mode
Contact Output
Timing Range(1)
Input Voltage
Cat. No.
(2)
24V AC/DC
ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with
pulse)
1 N.O.
0.05 s…10 hr (6 settings)
110…240V AC
50/60 Hz
700-FEM1TU22
24V…48V AC/DC
24…240V AC
50/60 Hz
ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with
pulse)
SPDT (1 C/O)
0.05 s…10 hr (6 settings)
700-FEM3TU23
(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr.
(2) Voltage is either 24V AC/DC 50/60 Hz.
Single-Function
This device offers you one specific timing function.
Operating Mode
Contact Output
Timing Range(1)
Input Voltage
Cat. No.
24V AC/DC
1 N.O.
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
0.05 s…10 hr (6 settings)
700-FEA1TU22
700-FEA3TU23
700-FEB1TU22
700-FEB3TU23
700-FED1TU22
700-FED3TU23
700-FEE3TU23
700-FEF1TU22
700-FEF3TU23
700-FEL3TU23
110…240V AC 50/60 Hz(2)
ON-delay
24V…48V AC/DC
24…240V AC 50/60 Hz
SPDT (1 C/O)
1 N.O.
24V AC/DC
110…240V AC 50/60 Hz(2)
OFF-delay
24V…48V AC/DC
24…240V AC 50/60 Hz
SPDT (1 C/O)
1 N.O.
24V AC/DC
110…240V AC 50/60 Hz(2)
One Shot
24V…48V AC/DC
24…240V AC 50/60 Hz
SPDT (1 C/O)
SPDT (1 C/O)
1 N.O.
24V…48V AC/DC
24…240V AC 50/60 Hz
Fleeting OFF-delay
24V AC/DC
110…240V AC 50/60 Hz(2)
Flasher (repeat cycle
starting with pulse)
24V…48V AC/DC
24…240V AC 50/60 Hz
SPDT (1 C/O)
SPDT (1 C/O)
24V…48V AC/DC
24…240V AC 50/60 Hz
Pulse Converter
(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr.
(2) Voltage is either 24V AC 50/60 Hz or 24V DC.
Special Functions
Operating Mode
Contact Output
Timing Range(1)
Input Voltage
Cat. No.
24V…48V AC/DC
24…240V AC 50/60 Hz
Star-Delta
2 N.O. with 1 Common
0.15 s…10 min (4 settings)
700-FEY2QU23
(1) Time ranges: 0.15…3 s, 0.5…10 s, 3 s…1 min, 30 s…10 min.
92
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories - 700-FE Relays
Description
Pkg. Quantity
Cat. No.
199-FSA
100-FMS
Panel Mounting Adapter
5
For surface mounting according to drilling plan EN 50 002
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
10
Function and Connection Diagrams - 700-FE Relays
(A) On-Delay
(B) Off-Delay
A1/A2
A1/A2
A1/B1
18
15
15
18
A1/A3
U
S
U
S
15
18
A1 B1
A2
18
t
Output
15
Output
LED
t
LED
A2
1 N.O. (SPST)
1 N.O. (SPST)
U
S
A1/A2
A1/B1
S
15
18
A1
A2
A1 B1
15
A1/A2
U
Output
LED
18
16
t
15
18
15
Output
LED
t
16
16
A2
18 16
1 C/O (SPDT)
1 C/O (SPDT)
(D) One Shot
(F) Flasher (Repeat Cycle Starting with Pulse)
15
18
A1
A2
A1/A2
A1/A2
A1
15
18
U
U
Output
LED
18
18
Output
15
t
t
t
15
t
t
t
LED
A2
1 N.O. (SPST)
1 N.O. (SPST)
15
A1
A2
15
A1/A2
A1
A2
U
A1/A2
U
Output
LED
18
18
Output
15
t
t
t
15
16
t
t
t
16
LED
18 16
18 16
1 C/O (SPDT)
1 C/O (SPDT)
(E) Fleeting Off-Delay
(L) Pulse Converter
1)
1)
S
A1/A2
B1
S
A1/A2
A1/B1
U
S
15
A1 B1
A2
15
A1
A2
B1
t
18
LED
15
18 16
Output
LED
t
t
16
18 16
1 C/O (SPDT)
(Y) Star-Delta Timing Relay
A1/A2
U
A1
A2
17
17/18
t
17/28
∆
tu = 50...65 ms
18
28
∆
LED
Bi-color light-emitting diode: 1 C/O (SPDT) or 1 N.O. Contact Timers
Single Color light-emitting diode: 2 N.O. with Common
LED U = green: Supply voltage available.
LED Relay = red: Output is energized.
ON = green
OFF = red
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
93
Relay and Timer Specifications
(1)
Specifications - 700-FE Relays
Attribute
700-FE
1 N.O.
SPDT
Setting Accuracy
Repeatability
5% of full scale
1% of setting (typical)
By voltage: 0.01%/%
Δ
U
By voltage: 0.001%/%ΔU
Tolerance
By temperature: 0.25%/°C
By temperature: 0.025%/°C
Supply
Supply Voltage
24V AC/DC(1) and 110…240V AC, 50/60 Hz
24…48V DC and 24…240V AC, 50/60 Hz
AC
–15%/+10%
–15%/+20%
VoltageTolerance
DC
Power Consumption
TimeEnergized
0.5 W at 24V DC, 5VA at 240V AC
100%
ResetTime
100 ms
Cable Length (Supply Voltage Control)
Max. 250 m (750 feet)
PulseControl(B1)
≥ 250 ms
Impulse Duration
Input Voltage
Input Current
≥ 50 ms (AC), ≥ 30 ms (DC)
supply voltage range
1 mA
Max.250mwithoutparallelloadbetweenB1andA2
Max. 50 m with load (< 3 k between B1 and A2
Cable Length
Ω
Outputs
1 N.O. contact
Contact Type
1 Form C – SPDT contact
Dielectric Withstand
Contact-to-coil
Voltage
4000V
Power
1250VA
AC-1
AC-14
DC-13
5 A /250V AC (resistive load)
1 A/250V AC (inductive load)
1 A/24V DC (inductive load)
According to IEC 947-
5-1
Switching Capacity
According to UL 508
NEMA D300 - 1 A/300V AC
Short circuit Resistance
Life
6 A gL (Fast Blow Fuse)
20 million operations
Mechanical
Electrical
0.4 million at 1 A/250V AC, resistive
0.4 million at 0.5 A/250V AC, cos φ = 0.4
0.4 million at 1 A/24V DC, resistive
State Indicator
Certifications
Standards
1 bicolor light-emitting diode (Supply; Relay)
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked
EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14
2 kV AC/50 Hz test voltage according to VDE 0435
and 4 kV 1.2/50 μs surge voltage according to IEC 60947-1 between all inputs and outputs
Insulation Characteristics
The following requirements are fulfilled:
Surge capacity of the supply voltage according to IEC 61000-4-5: Level 3
Burst according to IEC 61000-4-4: Level 3
EMC/Interference Immunity
ESD discharge according to IEC 61000-4-2: Level 3
EMC / Emission
electromagnetic fields according to EN 55 022: Class B
(1) Time Characteristics (according to VDE 0435, part 2021)
94
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
700-FE
Safe Isolation
according to VDE 0106 T 101
56 cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 60068-2-30
4 g in three axes at 10…500 Hz, test FC according to IEC 60068-2-6
50 g according to IEC 68-2-27
Climatic Withstand
Vibration Resistance
Shock Resistance
Enclosure: IP40
Terminal: IP 20
Protection Class IEC 60947-1
Weight
60 g
60 g
cULus, Germanischer Lloyd, CE Certified
Certifications
cULus, CE Certified
Open: –25…+60 °C
Enclosed: –25…+45°C
Storage: –40…+85 °C
Ambient Temperature
Connections
Screw terminal M3 for Pozidriv No.1, Philips, and slotted screws No.2. suitable for power screwdriver.
Rated tightening torque 8.8 lb.-in. (max. 1.0 Nm)
2
2
2
For terminal cross-sections of 1 x 0.5 mm …2 x 1.5 mm (solid) or 2 x 1.5 mm (stranded with sleeve), #20…14 AWG. Finger
protection according to EN 50274
Mounting
For surface mounting in any position; snap-on mounting on 35 mm DIN Rail or by adapter and two screws (M4 type)
Synthetic materials without dioxin according to EC/EFTA-Notification No. 93/0141/D electrical contacts are AgCdO
Disposal
(1) Voltage is either 24V DC or AC 50/60 Hz.
Dimensions - 700-FE Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
13
(0.51)
22.5
(0.89)
43.0
(1-11/16)
75.0
(2.95)
80.0
45.0
4.3
(0.17)
35.0
(1.38)
(3-5/32)
(1-25/32)
58.0
(2.28)
17
(0.67)
12
(0.47)
66.0
2.0
(0.08)
4.3
(0.17)
(2-9/16)
17.5
70.0
(11/16)
(2-49/64)
9.0
(0.35)
5.5
(0.22)
Cat. No. 700-FE…
Cat. No. 199-FSA…
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
95
Relay and Timer Specifications
700-FS High Performance Timing Relay
•
•
•
•
•
•
•
Adjustable function and timing range timing relays
DIN Rail mounted without cost of socket
22.5 mm wide multi-function or single functions
Available as SPDT or DPDT contact output, 8 A
Timing Ranges From 0.05 s…60 hr
Coil surge protection
Hazardous location version available
Catalog Number Explanation - 700-FS Relays
700
–
FS
H
3
U
–
U23
a
b
c
d
e
f
a
b
c
d
e
f
-
Bulletin
Type of
Relay
Operating Mode
Contact Output
Timing Range
Input Voltage
Number
A–0.05…1 s
B–0.15…3 s
C–0.5…10 s
A–On-delay
B–Off-delay
C–On- and off-delay
D–One shot
D–1.5…30 s
E–0.05…1 min
F–0.15…3 min
G–0.5…10 min
H–1.5…30 min
I–0.05…1 hr
J–0.15…3 hr
K–0.5…10 hr
L–3.0…60 hr
U–0.05 s…60 hr (1)
E–Fleeting off-delay
3–One changeover
contact (SPDT)1 C/O
Z12–12V DC
U23–24…48V DC | 24…240V AC 50/60 Hz
700
FS
F–Flasher (repeat cycle starts with pulse)
G–Flasher (repeat cycle starts with pause)
I–On-delay pulse generator
J–On-delay (pulse controlled)
K–One shot/watch dog (pulse controlled)
L–Pulse converter
(1) Valid for functions "A" and "B" only.
Single Function (With 2PDT 2 C/O contacts)
Operating Mode
Contact Output
Timing Range(1)
Input Voltage
12V DC
Cat. No.
On-delay
(DPDT) 2 C/O
700-FSA4UZ12
24…48V DC
On-delay
Off-delay
Off-delay
(DPDT) 2 C/O
(DPDT) 2 C/O
(DPDT) 2 C/O
700-FSA4UU23
24…240V AC, 50/60 Hz
0.05 s…60 hr
12V DC
700-FSB4UZ12
700-FSB4UU23
24…48V DC
24…240V AC, 50/60 Hz
(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.
(1)
Single Function With Hazardous Location Certification (With SPDT 1 C/O contacts)
Operating Mode
Contact Output
Timing Range
0.05 s…1 s
Input Voltage
Cat. No.
24…48V DC
24…240V AC
50/60 Hz
700-FSK3AU23-EX
700-FSK3CU23-EX
One Shot / Watch Dog
(Pulse Controlled)
(SPDT) 1 C/O
0.5 s…10 s
96
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Multi-Function
This device allows the flexibility of selecting one of 8 single timing functions.
Operating Mode
Contact Output
Timing Range
Input Voltage
Cat. No.
(SPDT) 1 C/O
12V DC
700-FSM3UZ12
24…48V DC
24…240V AC
50/60 Hz
Multi-function timing relays
(SPDT) 1 C/O
(DPDT) 2 C/O
(DPDT) 2 C/O
700-FSM3UU23
700-FSM4UZ12
700-FSM4UU23
8 Single-functions:
A, B, C, D, E, F, I, and L
0.05 s…60 hr
ON and OFF function additional
(for installation and maintenance)
note: See connection diagrams for further description.
12V DC
24…48V DC
24…240V AC
50/60 Hz
(1)
Multi-Function With Hazardous Location Certification
This device allows the flexibility of selecting one of 8 single timing functions.
Operating Mode
Contact Output
Timing Range(1)
Input Voltage
Cat. No.
M Multi-function timing relays
8 Single-functions:
(SPDT) 1 C/O
700-FSM3UU23-EX
24…48V DC
24…240V AC
50/60 Hz
A, B, C, D, E, F, I, and L
0.05 s…60 h
ON and OFF function additional
(for installation and maintenance)
Note: See connection diagrams for further description.
(DPDT) 2 C/O
700-FSM4UU23-EX
(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.
Special Function
Operating Mode
Contact Output
Timing Range
Input Voltage
Cat. No.
12V DC
700-FSH3UZ12
0.05 s…60 hr (2)
24…48V DC
24…240V AC
50/60 Hz
700-FSH3UU23
Flasher (repeat cycle starting with pulse or pause)
(SPDT) 1 C/O
12V DC
700-FSH3VZ12
700-FSH3VU23
2 x 0.05 s…60 hr (2 ranges)
0.15 s…10 min(3)
24…48V DC
24…240V AC, 50/60 Hz
(SPDT) 1 C/O
(DPDT) 2 C/O
24…240V DC
24…240V AC
50/60 Hz
700-FSQ3QU18
700-FSQ4QU18
700-FSY2CU23
700-FSY2DU23
700-FSY2EU23
700-FSY2FU23
700-FSY2GU23
OFF-delay without supply voltages (True OFF-delay)(1)
0.5 s…10 s
1.5…30 s
24…48V DC
Star-Delta
2 N.O. + 1 Common
0.05 s…1 min
0.15…3 min
0.5…10 min
24…240V AC
50/60 Hz
(1) Due to shock during shipment, the state of the contacts should be verified before initial use. Minimum power on time is 800 msec
(2) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.
(3) This time range is selectable in four smaller ranges: 0.15 s…2.5 s, 0.5 s…10 s, 4 s…80 s, 30 s…10 min.
(1) Temp. Code T4A 2A 32VDC MAX.: II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X 2A 32VDC MAX. Ta 70 °C
Ind. Cont. Eq. for Hazardous Location Listed 87SL Class 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IIC
Subject devices are to be installed in an ATEX Certified IP54 (as defined in IEC 60529) enclosure and accessible only by the use of a tool.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
97
Relay and Timer Specifications
Multi-Function Timing Relay Function and Time Range Settings - 700-FS Relays
Description
SPDT
DPDT
Multi-function timing relays 700-FSM3U includes 10 setting functions:
Multi-Time Setting Range 0.05 s…60 h
(A)On-Delay
(B)Off-Delay
(1 s) 0.05…1 s
(3 s) 0.15…3 s
(10 s) 0.5…10 s
(1 min) 0.05…1 min
(3 min) 0.15…3 min
(10 min) 0.5…10
min
(1 hr) 0.05…1 hr
(3 hr) 0.15…3 hr
(10 hr) 0.5…10 hr
(60 hr) 3.…60 hr
(C)On- and Off-Delay
(D)One shot
(E)Fleeting Off-Delay
(F)Flasher (repeat cycle starts with pulse)
(I)On-Delay pulse generator
(L)Pulse converter
(On)ON-Function (1)
(Off)OFF-Function(1)
Note: Switch ⊗ is on DPDT relays only. When switch is down, one contact is instantaneous and one is timed.
When switch is up, both contacts are timed.
(1) For installation and maintenance.
Accessories - 700-FS Relays
Description
Pkg. Quantity
Cat. No.
Setting Knob with Scale
(for time setting without tools)
10
700-FSK
Panel Mounting Adapter
For surface mounting according to drilling plan EN 50 002
5
199-FSA
Label Sheet
10
100-FMS
100-FMP
105 self-adhesive paper labels each, 6 x 17 mm
Marking Tag Sheet
160 perforated paper labels each, 6 x 17 mm, to be used with a transparent 10
cover
Transparent Cover
100
100
100-FMC
To be used with marking tag sheets
Marking Tag Adapters
To be used with marking tag: System 1492 W
(1)
100-FMA2
(1) Cat. No. 100-FMA2 is only a marking tag carrier. Please refer to the Terminal Block Accessories section, Marking Solutions of this publication for appropriate marker cards to be used with this carrier.
IMPORTANT Versatile Mounting: The 700-FS timing relay can be panel or DIN rail mounted. For best long-term performance, allow at least
5 mm (0.2 in.) of space on each side of the relay for proper ventilation.
98
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Function and Connection Diagrams - 700-FS Relays
(A) On-Delay
(G) Flasher (Repeat Cycle Starts with Pause)
Output
(I) On-Delay Pulse Generator
(B) Off-Delay (Min. Pulse AC 50 ms…DC 30 ms)
Output
LED
(3)
(J) On-Delay (Pulse Controlled)
(1)
Output
LED
(C) On- and Off-Delay
(1)
(K) One Shot/Watch Dog (Pulse Controlled)
Output
LED
(3)
(1)
Output
LED
(D) One Shot
(On) ON-Function (Off) OFF-Function
Output
(3)
Output 1
Output 2
LED
Output 1
Output 2
LED
(E) Fleeting Off-Delay (Min. Pulse AC 50 ms…DC 30 ms)
(L) Pulse Converter (Min. Pulse AC 50 ms…DC 30 ms)
(1)
Output
LED
t
(1)
(3)
Output
LED
(F) Flasher (Repeat Cycle Starts with Pulse)
(3)
Output
Cleverly Designed Function Display light-emitting diode (Green)
(3)
Output in Rest Position, No Timing
(1)
Output in Rest Position, Time Running
Output in Operation Position, No Time Running
Output in Operation Position, Time Running
(1) A voltage other than the supply voltage can be used at B1, but must be within voltages specified on timer.
(2) Output 2 is selectable as instantaneous contact with sliding switch (⊗) on front panel (instantaneous when switch is down, timed when switch is up).
(3) Available on multifunction "M," and single function "A" or "B" option timing relays along with code "4" (2PDT contacts).
Bridge or potentiometer 10 kΩ, 0.25 W min. (low voltage) for external time setting. Set timer dial to 0.0.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
99
Relay and Timer Specifications
Special Function Flasher Timing Relay
Description
t
Setting
Switch
2
Up
Supply Voltages (A1/A2)
Z12 12V DC
U23 24…48V DC, 24…240V AC, 50/60 Hz
Down
1 Range Setting
Seperate Range
Settings
t
Setting
1
700-FSH3U
700-FSH3V
Function Diagram / Connection Diagram(1)
(H) Flasher (Repeat Cycle Starting with Pulse or Pause)
The repeat cycle timer permits different settings for on and off times. The following operating modes are possible:
•
•
•
•
Oscillating mode; repeat cycle starts with voltage that is applied at A1 and B1, and continues to repeat until voltage is off.
One cycle mode; started by energizing B1 with voltage on A1 and A2.
Output starts with pulse or pause (switch ⊗ Up or Down).
700-FSH3U provides (1) range setting for t and t
1
2
700-FSH3V provides (2) range settings for t and t
1
2
Supply Voltage Controlled, Oscillating Mode Starting with Pause
— Switch ⊗ Is up
Supply Voltage Controlled, Oscillating Mode Starting with Pulse
— Switch ⊗ is Down
A1/A2
A1/B1
U
S
A1/A2
A1/B1
U
S
15
B1
A1
B1
15
A1
A2
t2
t2
t1
t1
18
t1
t1
18
t2
t2
15
15
Output
LED
Output
LED
16
16
A2
18 16
18
16
Pulse Controlled, Output Starts With Pause (Min. Pulse AC 50 ms
Pulse Controlled, Output Starts with Pulse (Min. Pulse AC 50 ms
— DC 30 ms) — Switch ⊗ is Up One Cycle Mode
— DC 30 ms) — Switch ⊗ is Down One Cycle Mode
— Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will
Initiate One Cycle.
— Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will
Initiate One Cycle.
A1/A2
U
S
U
S
A1/A2
S
B1
s
B1
15
A1
A2
A1
A2
15
A1/B1
18
A1/B1
t2
t1
18
15
t1
t1
t2
t1
t2
t2
15
16
Output
LED
Output
LED
16
18 16
18 16
(1) If B1 is pulsed, a one full time cycle consisting of t1 and t2 is completed.
LED Operation Chart Ñ Green LED
LED
LED
LED
LED
Output at Shelf State, No Timing - LED OFF
Output at Shelf State, Time is Running - LED Flashing
Output NO Contact is Closed, No Timing - LED On
Output NO Contact is Closed, Time is Running - LED Long Flashing
100
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Function Diagram / Connection Diagram(1)
(Q) Off-Delay without Supply Voltage (True Off-Delay)
•
When input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the
time delay.
tp
tp
U
A1/A2
U
A1/A2
18
16
15
25
A1
A2
A1
A2
15
t
t
t
18
15
15
Output 1
Output
LED
16
28
25
Output 2
LED
26
18 16
28 26
16
18
(Y) Star-Delta Timing Relay
•
When power is applied, the output contact 17/18(Y) changes state. After the time setting, the output contact 17/18(Y) returns to shelf state. After the fixed time (50… 60 ms),
the output contact 17/28Δ changes state. Both output contacts return to shelf state whenever the power is removed.
A1/A2
17/18
17/28
U
A1
17
t
tu = 50...65 ms
A2
28
18
LED
(1) Min. pulse (tp) required: 800 ms
(1)
Input Current
1 mA
Specifications - 700-FS Relays
Max. Leakage Current
Cable Length
400 micro Amps
Attribute
Value
Max. 250 m (800 ft) without parallel load between B1 and A2,
Setting Accuracy
Repeatability
5% of full scale
M a x . 5 0 m ( 1 6 0 f t ) w i t h l o a d ( < 3 k Ω) betweenB1andA2
0.2% of the setting values
Voltage: 0.001%/%
Outputs
ΔU
Tolerance
Temperature: 0.025%/°C
Contact Type
Relay as changeover switch
5000 V
Dielectric Coil to Contact
Supply
Voltage: 440V AC
Current Ith (AC-1): 8 A (5 A for 700- FSQ)
Power: 2000 VA
Attribute
Value
Supply Voltages
VoltageTolerance
Power Consumption
TimeEnergized
ResetTime
24…48V DC and 24…240V AC, 50/60 Hz (multi voltage)
–20…+20%(DC), –15…+10% (AC)
0.5 W at 24V DC, 5 VA at 240V AC
100%
According to IEC 947-5-1:
3 A/440V AC (inductive load, AC 14)
3 A/250V AC (inductive load, AC 15)
1 A/24V DC (inductive load, DC 13)
According to UL 508:
Switching Capacity
50 ms
Voltage Interruption
Input Impedance
≥20 ms without reset (supply voltage)
Relay ON: 3K-13K ohms, Relay OFF: 0.7K-4K ohms
1.5 A/250V AC (B300)
3 A/120V AC (B300)
Short-Circuit Resistance
10 A gL
Cable Length (Supply
Voltage Control)
Max. 250 m (800 ft)
Pulse Control (B1)
Attribute
Value
Pulse Duration
Input Voltage
≥50 ms (AC), ≥30 ms (DC)
Supply voltage range
(1) Time Characteristics (according to VDE 0435, Part 2021)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
101
Relay and Timer Specifications
Mechanical: 30 million operations
Electrical operations:
4 mil at 1 A/250V AC, cos φ = 1
0.2 mil at 6 A/250V AC, cos φ = 1
1.5 mil at 1 A/250V AC, cos φ = 0.3
0.3 mil at 3 A/250V AC, cos φ = 0.3
0.5 mil at 6 A/24V DC, resistive
2 mil at 4 A/24V DC, resistive
Life
2 mil at 0.2 A/230V DC, resistive
1 mil at 0.4 A/24V DC, L/R = 20 ms
1 mil at 0.2 A/110V DC, L/R = 20 ms
1 mil at 0.1 A/230V DC, L/R = 20 ms
1 LED, combination signal
State Indicator
General Data- 700-FS Relays
2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 μs surge voltage according to IEC 947-1 between all inputs and outputs
Insulation Characteristics
Performance of following requirements:
Surge capacity of the supply voltage according to IEC 1000-4-5: 4 kV 1.2/50 μs
Burst according to IEC 1000-4-4: 6 kV 6/50 ns
EMC/Interference Immunity
ESD discharge according to IEC 1000- 4-2:
Contact 8 kV, air 8 kV
Electromagnetic HF field according to IEC 801-3 and conducted electromagnetic HF signal according to IEC 801-6: Level 3
Electromagnetic fields according to EN 55 022: class B
According to VDE 106, part 101
EMC/Emission
Safe Isolation
56 Cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 68-2-30 and
IEC 68-2-3
Climatic Withstand
4 g in three axes at 10…500 Hz, test FC according to IEC 68-2-6
50 g according to IEC 68-2-27
Vibration Resistance
Shock Resistance
Enclosure: IP40
IP 30 (Single-function)
Terminal: IP 20 according to IEC 947-1
Protection Class
100 g
Weight
Approval
UL, C-UL
Open: –25…+60 °C
Enclosed: –25…+45 °C
Storage: –40…+85 °C
Ambient Temperature
Terminals
Screw terminal M3.5 for Number 2 Posidriv, Philips, and slotted screws. Suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (0.8 N•m,
max. 1.2 N•m).
2
2
2
Dual-chamber system for terminal cross-sections of 1 x 0.5 mm …2 x 2.5 mm (solid) or stranded 2 x 2.5 mm (flexible with sleeve), #20…14 AWG.
Finger protection according to VDE 0106.
Mounting
Disposal
Front mounting; For snap-on mounting on 35 mm DIN Rail or screw fixing by adapter and 2 screws (M4 type)
Synthetic material without dioxin according to EC/EFTA notification Number 93/0141/D electrical contacts with cadmium
cULus Listed (File No. E14840, Guide NKCR/NKCR7),CE Marked
Certifications
Standards
EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14
Temp. Code T4A
2A 32VDC MAX.
Mounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021.
102
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HNC Miniature Timing Relay
•
•
•
•
•
Miniature timer, perfect for converting 700-HC "Ice Cube" relays into timing relays
4 operating modes
4PDT contact output
Timing range from 0.1 s…10 hr
Socket mounted
Model
Timing Mode
Contact Output
Input Voltages
Timing Range
0.1 s…10 min
.1 min…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
0.1 s…10 min
0.1 min.…10 hr
Socket Type
Cat. No.
700-HNC44AZ12
700-HNC44BZ12
700-HNC44AZ24
700-HNC44BZ24
700-HNC44AZ48
700-HNC44BZ48
700-HNC44AZ11
700-HNC44BZ11
700-HNC44AZ25
700-HNC44BZ25
700-HNC44AA24
700-HNC44BA24
700-HNC44AA12
700-HNC44BA12
700-HNC44AA23
700-HNC44BA23
12V DC
24V DC
48V DC
On-Delay
One Shot
Repeat cycle, OFF-start
Repeat cycle, ON-start
100…110V DC
125V DC
700-HN103
700-HN128
4PDT
24V AC
100…120V AC
200…230V AC
Cat. No. 700-HNC
Accessories - 700-HNC Relays
Photo
Description
Pkg. Quantity
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting.
Guarded Terminal Construction
10
10
700-HN103
700-HN128
14-Blade miniature socket for use with 700-HNC timers.
Screw Terminal Base Sockets — Panel or DIN Rail Mounting.
Open Style Construction
14-blade miniature socket for use with 700-HNC timers.
Screw Terminal Socket – Panel or DIN Rail Mounting. Guarded Terminal
Construction 14-blade miniature socket for use with 700-HNC timers. This socket has coil 10
700-HN104
700-HN263
and contact separation.
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HNC Timers.
Secures Timer in Socket.
10
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
103
Relay and Timer Specifications
Specifications - 700-HNC Relays
Attribute
Pilot Duty Rating
700-HNC
NEMA B300
Pin type
Plug-in
Operating voltage range
Reset voltage
85%…110% of rated supply voltage (12V DC: 90%…110% of rated supply voltage) (1)
10% min. of rated supply voltage
Relay ON:
Relay OFF:
1.5 VA(1.1 W) (at 24V AC, 60 Hz)
0.2 VA(0.1 W) (at 24V AC, 60 Hz)
24VAC:
100…120VAC:
200…230VAC:
12VDC:
Relay ON:
Relay OFF:
1.5 VA(1.3 W) (at 120V AC, 60 Hz)
0.8 VA(0.5 W) (at 120V AC, 60 Hz)
Relay ON:
Relay OFF:
1.8 VA(1.5 W) (at 230V AC, 60 Hz)
1.2 VA(0.9 W) (at 230V AC, 60 Hz)
Relay ON:
Relay OFF:
0.9 W (at 12V DC)
0.07 W (at 12V DC)
Power consumption
Relay ON:
Relay OFF:
0.9 W (at 24V DC)
0.07 W (at 24V DC)
24VDC:
Relay ON:
Relay OFF:
1.0 W (at 48V DC)
0.2 W (at 48V DC)
48VDC:
Relay ON:
Relay OFF:
1.3 W (at 110V DC)
0.3 W (at 110V DC)
100…110VDC:
125VDC:
Relay ON:
Relay OFF:
1.3 W (at 125V DC)
0.3 W (at 125V DC)
Controloutputs
4PDT: 5 A at 250V AC, resistive load (cos φ = 1)
Characteristics
120VAC
Make
30 A
240VAC
15 A
120VAC
Break
3 A
240VAC
1.5 A
Hp at 120V AC
1/6Hp
1/6Hp
Hp at 240V AC
Accuracy of operating time
Setting error
1% FS max. (1 s range: 1% 10 ms max.)
10% 50 ms FS max.
Reset time
Min. power-opening time: 0.1 s max. (including halfway reset)
2% FS max.
Influence of voltage
Influence of temperature
Insulation resistance
2% FS max.
100 mΩ min. (at 500V DC)
2000V AC, 50/60 Hz for 1 min (between current-carrying(t2e)rminals and exposed non-current-carrying metal parts)
2000V AC, 50/60 Hz for 1 min (between operating power circuit and control output)
2000V AC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)
1500V AC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)
1000V AC, 50/60 Hz for 1 min (between non-continuous contacts)
Malfunction: 10…55 Hz, 0.5 mm single amplitude
Dielectric strength
Vibration resistance
Shock resistance
2
Malfunction: 100 m/s (approx. 10G)
Operating: -10 °C…50 °C (with no icing)
Storage: -25 °C…65 °C (with no icing)
Ambient temperature
104
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
700-HNC
Ambient humidity
Life expectancy
Operating: 35%…85%
Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr)
Electrical: 4PDT: 200 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)
1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns / 1 μs, 1- ns rise)
Noise immunity
Static immunity
Enclosure rating
Weight
Destruction:8 kV Malfunction:4 kV
IP40
Approx. 50 g
Emission Enclosure:EN55011 Group 1 class A
Emission AC Mains:EN55011 Group 1 class A
Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3)
EMC
Immunity RF-interference:ENV50140:10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse
modulated, 900 MHz)
Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3)
Immunity Burst:EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4)
UL 508, CSA 22.2 No. 14, EN/IEC 61812-1
Standards
Certifications
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CSA Certified (File 224268), CE Marked, C- Tick Marked
(1) Single-phase, full-wave-rectified power supplies can be used.
(2) When using the 700-HNC continuously in any place where the ambient temperature is in a range of 45 °C…50 °C, supply 90%…110% of the rated supply voltages supply 95%…110% with 12V DC type).
General Timer Functions
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
105
Relay and Timer Specifications
Timing Charts - 700-HNC Relays
IMPORTANT t: Set time, Rt:Reset time
Operating Mode
Timing Charts / Wiring Diagram
Rt
t
t
ON-Delay
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3, 12-4)
Power
Time limit contact
NO (9-5, 10-6, 11-7, 12-8)
t
Output
Run / Power Indicator (PW)
Output Indicator (UP)
One shot
Power
Power (13-14)
Time limit contact
NC (9-1, 10-2, 11-3, 12-4)
Time limit contact
NO (9-5, 10-6, 11-7, 12-8)
Output
Run / Power Indicator (PW)
Output Indicator (UP)
t
t
t
t
Timer
Circuit
Power (13-14)
Repeat Cycle OFF-Start
Time limit contact
NC (9-1, 10-2, 11-3, 12-4)
Power
Time limit contact
NO (9-5, 10-6, 11-7, 12-8)
t
t
t
UP PW
Output
Run / Power Indicator (PW)
Output Indicator (UP)
t
t
t
t
Power (13-14)
Repeat Cycle ON-Start
Time limit contact
NC (9-1, 10-2, 11-3, 12-4)
Time limit contact
NO (9-5, 10-6, 11-7, 12-8)
Power
t
t
t
Output
Run / Power Indicator (PW)
Output Indicator (UP)
General Timer Functions
Pulse Operation
A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNC
timing relay in interval mode as shown in the following timing charts.
Output Indicator (Orange)
(Lit: Output ON)
Run/Power Indicator
(Green)
(Lit: Power ON)
1
5
3
7
4
8
2
6
Power (9-14)
Main Dial
External short circuit
(5-13)
External input
(9-13)
Set the desired time
according to time range
selectable by DIP switch.
50 ms
min.
Time limit contact NO
(10-6, 11-7, 12-8)
Time limit contact NC
(10-2, 11-3, 12-4)
Run/Power indicator
(PW)
Output indicator (UP)
9
11
12
14
10
13
Timer
Circuit
(—)
( )
+
( )
~
(
~
)
UP FW
External Input
~
Note: t: Set time
(
)
Rt: Reset time
106
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
DIP Switch Settings - 700-HNC Relays
Time Ranges
Cat. No.
Time Range
Time Setting Range
Setting
Factory-Set
700-HNC44AZ12
700-HNC44AZ24
700-HNC44AZ48
700-HNC44AZ11
700-HNC44AZ25
700-HNC44AA24
700-HNC44AA12
700-HNC44AA23
1 s
10 s
0.1 s…1 s
Yes
1 s…10 s
0.1 s…1 min
1…10 min
0.1…1 min
1…10 min
0.1…1 hr
No
No
No
Yes
No
No
No
1 min
10 min
1 min
10 min
1 hr
700-HNC44BZ12
700-HNC44BZ24
700-HNC44BZ48
700-HNC44BZ11
700-HNC44BZ25
700-HNC44BA24
700-HNC44BA12
700-HNC44BA23
1 hr
1…10 hr
Note: The top two DIP switch pins are used to select the time ranges.
Operating Mode
Setting
Factory-set
ON-delay
Yes
No
No
No
One Shot
Repeat Cycle OFF-start
Repeat Cycle ON-start
Note: The top two DIP switch pins are used to select the time ranges.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
107
Relay and Timer Specifications
Dimensions - 700-HNC Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
30.0
24.9
(57/64)
21.1
(1-3/16)
6.1 (15/64)
(53/64)
5
1
8
4
6
2
7
3
Fourteen 3 x 1.2 mm
Elliptic Holes
4.2
(5/32)
62.0
(2-15/64)
28
(1.10)
6.3
65.0
(2-9/16)
14
12
13
9
(.024)
4.0
(0.15)
6.4
(0.25)
52.6
10
11
21.5 max
(084)
(2.07)
63.0
(2.48)
26.0
(1-1/64)
Cat. No. 700-HNC…
Cat. No. 700-HN128 (1)
Wire Size: 2 x 1.5 mm (#2-16 AWG…#1-20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb•in)
2
27.0
(1.06)
60.9
(2.40)
Panel Mounting
21.5
(0.85)
28.9
(1-9/64)
24.5
(31/32)
76.0
(2.99)
35.6
(1.40)
67.0
(2-5/8)
3.2
(0.13)
18.9
(0.74)
34.9
(1.37)
32.0
(1.26)
35.5
(1.40)
#4-40
M3
30.0
(1-11/64)
2.5
(0.10)
Cat. No. 700-HN103
Cat. No. 700-HN104
2
2
Single wire: 0.2…2.5 mm (#24 AWG…14 AWG)
Single Wire: 0.2…2.5 mm ( #24 AWG…14 AWG)
2
2
2
2
Double wire: 2 x 0.2 mm …2 x 1.5 mm (2 x 24 AWG…2 x 16 AWG)
Wire type: solid or stranded, copper only
Double Wire: 2 x 0.2 mm …2 x2.5 mm (2 x 24 AWG…2 x 14 AWG)
Wire Type: solid or stranded, copper only
Strip length: 8 mm (5/16 in.), Torque: 0.5 N•m (4.4 lb•in)
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)
(1) Total height of 700-HN128 + 700-HNC is 82.5 mm.
108
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HNK Ultra-Slim Timing Relay
•
•
•
•
•
The ultra-slim timing relay is the smallest relay available
It is perfect for converting 700-HK relays into a timing relay
SPDT and DPST-NO contact output
Socket-mounted
Timing range From 0.1 s…10 hr
Photo
Timing Mode
Socket Type
Contact Output
Timing Range
Input Voltage
12V DC
24V DC
24V AC
Cat. No.
700-HNK41AZ12
700-HNK41AZ24
700-HNK41AA24
700-HNK41BZ12
700-HNK41BZ24
700-HNK41BA24
700-HNK42AZ12
700-HNK42AZ24
700-HNK42AA24
700-HNK42BZ12
700-HNK42BZ24
700-HNK42BA24
0.1 s…10 min
700-HN121
SPDT (1)
12V DC
24V DC
24V AC
0.1 min…10 hr
0.1 s…10 min
0.1 min…10 hr
On-Delay
One Shot
Repeat Cycle, OFF-start
Repeat Cycle, ON-start
12V DC
24V DC
24V AC
700-HN122
DPST-NO(2)
12V DC
24V DC
24V AC
(1) 5-blade terminal type only.
(2) 8-blade terminal type only.
Accessories - 700-HNK Relays
Description
Pkg. Quantity
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting
5-blade miniatue socket. For use with 1-pole type 700-HNK41 timers. Socket includes a retainer clip.
10
700-HN121
Screw Terminal Socket — Panel or DIN Rail Mounting
8-blade miniature socket for use with 2-pole, 700-HNK42 timers. This socket includes a retainer clip.
10
700-HN122
Sockets and Retainer Clip Reference
Timer Type
Socket Cat. No.
700-HN121
Retainer Clip Cat. No.
Provided
700-HNK
700-HN122
Provided
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
109
Relay and Timer Specifications
Specifications - 700-HNK Relays
Attribute
Pilot Duty Rating
700-HNK
NEMA B300
Rated Supply Voltage
Pin Type
24V AC; 12, 24V DC
Plug-in
Operating Mode
ON-delay, One Shot, Repeat Cycle OFF start, or Repeat Cycle ON start selectable with DIP switch.
85%…110% of rated supply voltage (12 VDC: 90%…110% of rated supply voltage) (1)
Operating Voltage Range
24V AC:Relay ON:approx. 0.8 VA (at 24 VAC, 60 Hz) Relay OFF:0.5 VA (at 24V AC, 60 Hz)
12V DC:Relay ON:approx. 0.4 W (at 12V DC) Relay OFF:0.1 W (at 12V DC)
24V DC:Relay ON:approx. 0.5 W (at 24V DC) Relay OFF:0.2 W (at 24V DC)
Power Consumption
5 A at 250V AC, resistive load (cos φ = 1)
The minimum applicable load is 10 mA at 5 VDC (P reference value).
Control Outputs
Characteristics
120V AC
Make
30 A
240V AC
15 A
120V AC
Break
3 A
240V AC
1.5 A
1/6 Hp
Hp at 240V AC
Accuracy of Operating Time
Setting Error
1% FS max. (1 s range: +1% 10 ms max.)
15% +50 ms FS max.
12, 24V DC: 0.1 s max. (including halfway reset)
Min. power-opening time:
Reset Time
24V AC: 0.5 s max. (including halfway reset)
Influence of Voltage
2% FS max.
2% FS max.
Influence of Temperature
Insulation Resistance
100 mΩmin.(at500VDC)
2000V AC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different poles)
1000V AC, 50/60 Hz for 1 min (between non-continuous contacts)
Dielectric Strength
Vibration Resistance
Shock Resistance
Malfunction: 10…55 Hz, 0.5 mm single amplitude
2
Malfunction: 100 m/s (approx. 10G)
Operating: -10 °C…50 °C (with no icing)
Storage: -25 °C…65 °C (with no icing)
Ambient Temperature
Ambient Humidity
Life Expectancy
Operating: 35…85%
Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr)
Electrical: 100 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)
Impulse Withstand Voltage
Noise Immunity
Between power terminals: 1 kV
1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Destruction: 8 kV
Malfunction: 4 kV
Static Immunity
Enclosure Rating
Weight
IP20
Approx. 18 g
110
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
700-HNK
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Immunity ESD: EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3)
EMC
Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz…1GHz) (level 3) 10 V/m (pulse
modulated, 900 MHz)
Immunity Conducted Disturbance: ENV50141:10 V (0.15…80 MHz) (level 3)
Immunity Burst: EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4)
Standards
UL508, CSA C22.2 No. 14, EN/IEC 60947-5-1, EN/IEC 61812-1
Certifications
cURus Recognized Component (File No. E14843, Guide NRNTZ/NRNT8), CE Marked, C-Tick Marked
(1) When using 700-HNK timer in any place where the ambient temperature is more than 50 °C, supply 90…110% of the rated voltages (12V DC: 95…11% of the rated voltage).
IMPORTANT t: Set time, Rt:Reset time
General Timer Functions
Run/Power Indicator (Green)
(Lit: Power ON)
Main Dial
Set the desired time according to time
range selectable by DIP switch.
Output Indicator (Orange)
(Lit: Output ON)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
111
Relay and Timer Specifications
Operating Mode
Timing Charts / Wiring Diagram
700-HNK41…
700-HNK42…
Rt
t
t
Rt
t
t
ON-Delay
Power (1-5)
Power (1-8)
Time limit contact
NC (4-2)
Time limit contact
NO 4-3, 5-6
Power
t
Time limit contact
NO (4-3)
Run/Power
indicator (PW)
Output
Run/ Power
Output indicator
(OUT)
Indicator (PW)
Output Indicator
(OUT)
Rt
Power (1-5)
t
t
One shot
Power
Power (1-8)
Time limit contact
NC (4-2)
Time limit contact
NO (4-3, 5-6)
Time limit contact
NO (4-3)
Run/Power
indicator (PW)
Output
Run/ Power
Output indicator
(OUT)
Indicator (PW)
Output Indicator
(OUT)
t
t
t
t
Power (1-5)
t
t
t
t
Repeat Cycle OFF-Start
Time limit contact
NC (4-2)
Power (1-8)
Time limit contact
NO (4-3, 5-6)
Power
Time limit contact
NO (4-3)
t
t
t
Run/Power
indicator (PW)
Run/ Power
Output
Output indicator
(OUT)
Indicator (PW)
Output Indicator
(OUT)
t
t
t
t
Power (1-5)
t
t
t
t
Repeat Cycle ON-Start
Power (1-8)
Time limit contact
NC (4-2)
Time limit contact
NO (4-3, 5-6)
Power
Time limit contact
NO (4-3)
t
t
t
Run/Power
indicator (PW)
Output
Run/ Power
Output indicator
(OUT)
Indicator (PW)
Output Indicator
(OUT)
112
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Wiring- 700-HNK Relays
3
4
5
6
4
2
3
1
Timer
Circuit
Timer
Circuit
8
5
1
(
(
)
(
)
(
)
(
)
)
~)
( ~ )
( ~ )
(
~
OUT
PW
PW
OUT
Cat. No. 700-HNK42...
Cat. No. 700-HNK41...
A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNK in interval mode as shown in the following timing chart.
5
4
Rt
Rt
t
t
t
Power (3-8)
External Short Circuit (1-4)
External Input (1-3)
3
1
6
50 ms
min.
8
Timer
Circuit
(
)
)
(
(
)
)
(
~
Time Limit Contact NO (6-5)
~
OUT
PW
Run/Power Indicator (PW)
Output Indicator (OUT)
External Input
~
(
)
Note:t:Set time
Rt: Reset time
Mode
Terminals
Power supply between 3 and 8
Short-circuit between 4 and 1
Input signal between 3 and 1
Pulse Operation
Operating mode; One shot and all other modes
Power supply between 1 and 8
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
113
Relay and Timer Specifications
Time Ranges- 700-HNK Relays
Cat. No.
Time Range
Time Setting Range
Setting
Factory-Set
1 s
0.1…1 s
Yes
700-HNK41AZ12
700-HNK41AZ24
700-HNK41AA24
700-HNK42AZ12
700-HNK42AZ24
700-HNK42AA24
10 s
1…10 s
0.1 s…1 min
1…10 min
0.1…1 min
1…10 min
0.1…1 hr
No
No
No
Yes
No
No
No
1 min
10 min
1 min
10 min
1 hr
700-HNK41BZ12
700-HNK41BZ24
700-HNK41BA24
700-HNK42BZ12
700-HNK42BZ24
700-HNK42BA24
10 hr
1…10 hr
Note: The left two DIP switch pins are used to select the time ranges.
Operating Modes - 700-HNK Relays
Operating Mode
Setting
Factory-set
On-delay
One Shot
Yes
No
No
No
Repeat Cycle Off-start
Repeat Cycle On-start
Note: The right two DIP switch pins are used to select the operating modes.
114
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HNK Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
47.0
47.4
(1.86)
46.0
(1.81)
12.8
12.8
(0.50)
6
(0.23)
(1.86)
(0.50)
46.0
(1.81)
6.0
(0.23)
28.8
(1.30)
31.2
(1.22)
28.8
(1.13)
31.2
(1.22)
700-HNK41 SPDT Contact
700-HNK42 DPST-NO Contact
7.11
(9/32)
2.03
(5/64)
2.03
(5/64)
7.11
21
6
11
3
(9/32)
Five M3.5
x 0.315 Screws
11
4
22
Eight
4.06
(5/32)
7
M3.5 x 0.315
Screws
14
3
12
2
24
5
4.06
(5/32)
12
(1)
2
3.0 Ø
(1/8)
Use M3 Screws
39.5
(1-17/32)
35.5
(1-13/32)
14
84.1
(3-5/16)
39.5
(1-17/32)
4
84.1
(3-5/16)
(1)
3.0 Ø
(1/8)
35.5
(1-13/32)
5 (+)
(A1)
Use M3 Screws
8 (+)
(A1)
1 (-)
(A2)
4.06
(5/32)
4.06
(5/32)
1 (-)
(A2)
29.9
(1-3/16)
15.6
(5/8)
29.9
(1-3/16)
15.6
(5/8)
54.1
(2-1/8)
54.1
(2-1/8)
Cat No. 700-HN121
Cat No. 700-HN122
2
2
Wire Size: 2 x 2.5 mm
Wire Size: 2 x 2.5 mm
Single Wire – Up to #12 AWG
Single Wire – Up to #12 AWG
2
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)
(Either Solid or Stranded)
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Total height: 700-HN121 + 700-HNK41 is 78.0 mm.
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)
Total height: 700-HN122 + 700-HNK42 is 78.0 mm.
(1) Holes required for mounting [3 mm (1/8 in.) diameter].
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
115
Relay and Timer Specifications
700-HR Dial Timing Relays
•
•
•
•
•
Socket- or panel-mounted
5 A contact ratings or transistor outputs
Single- or Multi-Function
Timing range from 0.05 s…300 hr
Multi-voltage inputs
Multi-Function Timing Relays with Trigger and Reset Switch Options
•
•
•
•
•
Socket or Panel Mounted
Timing Range From 0.05 s…300 hr
11-pin base for socket cat. nos. 700-HN101, -HN126, -HN129
Trigger: Power on or optional trigger signal
Reset: Power off or optional reset signal
Timing Mode
Supply Voltage
Trigger Options
Reset Options
Outputs
Cat. No.
1. Power On
DPDT
700-HR52TU24
1. Power Off
2. Start Signal
2. Reset Signal
- contact closure (zero volts)
- NPN transistor
3. Gate Signal (pause)
- contact closure (zero volts)
- NPN transistor
Transistor
DPDT
700-HRT6TTU24
(1)
24…48V AC
12…48V DC
On-Delay (A)
1. Power On
2. Start Signal
- contact closure (voltage)
- NPN transistor
- PNP transistor
OFF-Delay (D)
One Shot (E)
Power Off
700-HRV52TU24
Repeat cycle OFF-Start (B)
Repeat Cycle ON-Start (B2)
Signal ON/OFF-delay (C)
Delayed One Shot (J)
Signal ON/OFF - Delay (G)
1. Power On
1. Power Off
2. Start Signal
2. Reset Signal
DPDT
DPDT
700-HR52TA17
- contact closure (zero volts)
3. Gate Signal (pause)
- contact closure (zero volts)
100…240V AC
100…125V DC
1. Power On
(1)
2. Start Signal
Power Off
700-HRV52TA17
- contact closure (voltage)
(1) Voltage input connection to high signal instead of OV signal.
Multi-Function Timing Relays with Power On Trigger
•
•
•
•
•
Socket or Panel Mounted
Timing Range From 0.05 s…300 hr
8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108
Tri g g e r : Powe r o n
Reset: Power off
Timing Mode
Supply Voltage
Trigger Options
Reset Options Outputs
Cat. No.
DPDT
700-HRS42TU24
24…48V AC
12…48V DC
Power On
Power Off
Power Off
Power Off
ON-Delay (A)
One Shot (E)
Repeat Cycle OFF-Start (B)
Repeat Cycle ON-Start (B2)
Delayed One Shot (J)
Transistor
700-HRT4TTU24
700-HRP42TU24
(1)
24…48V AC/DC
Power On
Power On
SPDT Timed + Instantaneous Contact
SPDT Timed + Instantaneous Contact
DPDT
700-HRP42TA17
700-HRS42TA17
100…240V AC
100…125V DC
(1) Voltage input connection to high signal instead of OV signal.
116
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
ON-Delay Timing Relays
•
•
•
•
•
Socket or Panel Mounted
Timing Range From 0.05 s…300 h
8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108
Tri g g e r : Powe r o n
Reset: Power off
Timing Mode Supply Voltage
Trigger Options Reset Options Outputs
Cat. No.
24…48V AC/DC
SPDT Timed + Instantaneous Contact
700-HRC12TU24
700-HRM12TU24
700-HRM12TA17
700-HRC12TA17
Power On
Power Off
24…48V AC, 12…48V DC
DPDT
ON-Delay (A)
DPDT
100…240V AC
Power On
Power Off
SPDT Timed + Instantaneous Contact
Timing Mode Description
700-HRF Repeat Cycle Timing Relays
•
•
•
•
•
•
Socket or Panel Mounted
Independently adjustable on- and off-time
8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108
DPDT contact outputs
Tri g g e r : Powe r o n
Reset: Power off
•
Hazardous location version available
700
–
HRF
7
2
D
U26
a
b
c
d
e
f
Catalog Number Explanation
a
d
b
c
e
f
-
Bulletin
Type of Relay
Function
Timing Range
Supply Voltage
Contact Output
Number
7–Repeat cycle with OFF start
8–Repeat cycle with ON start
U26 - 12…48V DC, 24…48V AC
U27 - 100…125V DC, 100…240V AC
HRF–Repeat cycle with
adjustable ON/OFF times
700
2- DPDT
D–0.05 s…300 hr
700-HRY Star-Delta Timing Relays
•
•
•
•
8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108
SPDT timed + instantaneous contact outputs
Tri g g e r : Powe r o n
Reset: Power off
700
–
HRYY
6
F
A12
a
b
c
d
e
Catalog Number Explanation
a
b
c
d
e
-
Bulletin
Type of Relay
Function
Timing Range
Supply Voltage
Number
F–Star: 0.5…120 s
Delta: 0.05, 0.1, 1.25, 0.5, 0.75, 1.0 s
A12–100…120V AC, 50/60 Hz
A22–200…240V AC, 50/60 Hz
700
HRYY–YStar-Delta timer
6–SPDT timed + SPDT instant
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
117
Relay and Timer Specifications
700-HRQ True Off-Delay Timing Relays
•
•
•
•
11-Pin base for use with reset option — socket cat. nos. 700-HN101, -HN126, and -HN129
8-Pin base for use without reset option — socket cat. nos. 700-HN100, -HN125, and -HN108
DPDT contact outputs
Trigger: Power off
•
Reset: optional reset signal
700
–
HRQ
N
2
G
A12
a
b
c
d
e
f
Catalog Number Explanation
a
b
d
c
e
f
-
Bulletin
Type of Relay
Contact
Function
Timing Range
Supply Voltage
Number
Output
A12–100…120V AC, 50/60 Hz
A22–200…240V AC, 50/60 Hz
U25–24V AC, 50/60 Hz; 24V DC
Z48–48V DC
N–No reset option, 8-pin terminals
R–Reset option, 11-pin terminals
G–0.05…12 s
H–0.05…12 min
HRQ–True Off-
Delay Timer
700
2–DPDT
Z11–100…125V DC
Accessories - 700-HR Relays
Photo
Description
Pkg. Qty. Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 8-Pin for use with 700-HR and -HX timing relays.
10
700-HN100
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style
10
10
700-HN125
700-HN101
Construction. 8-Pin for use with 700-HR and -HX timing relays. No retainer clip required.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 11-pin for use with 3PDT 700-HA relays.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style
10
10
700-HN126
199-DR1
Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
118
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Photo
Description
Pkg. Qty. Cat. No.
Specialty Socket
8-pin backwired socket with solder terminals for use with 700-HR timing relays. Order 10 or
multiples of 10.
10
10
700-HN108
700-HN129
Specialty Socket
11-pin back-wired socket with solder terminals for use with 700-HR timing relays.
Frame Adapter
For flush or door mounting of all 700-HR and -HX timers.
1
700-HN130
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with all 700-HR Timing
Relays
Secures timer in socket.
10
1
700-HN131
700-HN132
Note: Not required for installation
Protective Cover
Helps prevent tampering of timing and mode settings. Provides a degree of protection against
water and dirt from entering the front of the relay. For use with all 700-HRs and -HX timing
relays.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank
tags. Tags are peel-off with sticky backing for easy placement on relays.
10
10
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing
for easy placement on relays.
Timer Type
Socket Cat. No.
700-HN101
Retainer Clip Cat. No.
700-HN131
(1)
700-HR52, -HRT6, -HRV, -HRQR
700-HN126
700-HN129
700-HN100
700-HN108
700-HN125
Not Required (3)
Not Applicable
700-HN131(See note above)
Not Applicable
Not Required(3)
(2)
700-HRS, -HRT4, -HRP, -HRC, -HRM, -HRF, -HRY, -HRQN
(1) 11 pins.
(2) 8 + pins.
(3) Design of these sockets holds the timing relays securely and does not require retainer clips.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
119
Relay and Timer Specifications
Specifications - 700-HR Relays
700-HR,
700-HRS,
700-HRV
700-HRP
700-HRC
700-HRM
700-HRF
700-HRY
700-HRQ
700-HRT
(Transistor
Outputs)
Electrical Ratings
Pilot Duty Rating
NEMA B300
5 A
—
100 mA @ 30V
DC max.
Thermal Current (I
)
th
120V AC
240V AC
120V AC
240V AC
30 A
15 A
3 A
—
—
—
—
Make
Break
1.5 A
1/6 Hp (0.12
kW)
1/4 Hp (0.18 1/6 Hp (0.12
kW) kW)
Hp at 120V
1/4 Hp (0.18 kW)
1/6 Hp (0.12 kW)
1/3 Hp (0.25 kW)
5 A at 250V AC/30V DC
AC-15 @ 250V AC, 3 A/DC-13 @ 30V DC, 0.5 A
0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)
—
—
Hp at 240V
Resistive Load
Inductive Load
Accuracy of Operating Time
Setting Error
5 % FS 50 ms (The value is 5% FS +100 ms to -0 ms max. when the C or D mode signal of the 700-HRVs are OFF.)
0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)
Influence of Voltage
Influence of Temperature
Permissible Leakage Current
Power Consumption
240V AC, Output ON
240V AC, Output OFF
24V DC, Output ON
1% FS max. ( 1% 10 ms max. in a range of 1.2 s)
-HR52,-HRS
2.1 VA
-HRV
2.5 VA
1.8 VA
0.9 W
0.3 W
-HRP,-HRC
2.0 VA
2.0 VA
0.9 W
-HRM
2.1 VA
1.3 VA
0.8 W
0.2 W
-HRF
10 VA
10 VA
1.0 W
1.0 W
-HRY
12 VA
12 VA
—
-HRQ
0.4 VA
0.4 VA
0.2 W
0.2 W
-HRT
—
1.3 VA
—
0.8 W
0.3 W
0.2 W
24V DC, Output OFF
Design Specifications
0.2 W
0.9 W
—
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (contact to frame)
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (between control output terminals and operating circuit)
2000V AC, 50/60 Hz for 1 min (pole-to-pole)
Dielectric Strength
1000V AC, 50/60 Hz for 1 min (between contacts not located next to each other)
2000V AC, 50/60 Hz for 1 min (contact to coil)
Mechanical
Vibration Resistance
Malfunction: 10…55 Hz with 0.5 mm double amplitude each in three directions for ten minutes each
2
2
98 m/s (10 294 m/s (10
2
2
2
Shock Resistance
Environmental
Noise Immunity
Static Immunity
Ambient Temperature
Malfunction: 100 m/s (10 G)
98 m/s (10 G) 100 m/s (10 G)
G)
G)
1kV for 48V
DC
1.5 kV for
600V DC
1.5 kV for 600V DC
400V for 12V DC
Malfunction: 8 kV
Operating: -10…+55 °C ( 14…131 °F) with no icing
Storage: -25…+65 °C ( 13…149 °F) with no icing
Ambient Humidity
Operating: 35…85 %
Construction
7
Life Rxpectancy (Min.
Operations)
Mechanical:20 000 000. (under no load at 1800 operations/h)
Electrical: 100 000 (5 A at 250V AC, resistive load at 1800 operations/h)
Mech: 10
4
Electrical: 10
120
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HR,
700-HRS,
700-HRV
700-HRP
700-HRC
700-HRM
700-HRF
700-HRY
700-HRQ
700-HRT
(Transistor
Outputs)
(EMI) EN50081-2
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN50082-2
Immunity ESD:EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: ENV50140:10 V/m (80 MHz…1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204:10 V/m (900 5 MHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10V (0.15…80 MHz) (level 3)
Immunity Burst: EN61000-4-4:2 kV power-line (level 3)
EMC
Immunity Surge: EN61000-4-52 kV I/O signal-line (level 4)
1 kV line to line; 2 kV line to ground (level 3)
Degree of Protection
Weight
IP40 (panel surface)
Approx. 90 g
Certifications
Standards
CSA Certified (File No. 70751), UL Recognized (File No. E14843 Guide No. NRNT2), CE Marked, C-Tick Marked
UL 508, CSA C22.2 No. 14, EN 61812-1, EN 61000-6-2, -6-4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
121
Relay and Timer Specifications
Timer Functions - 700-HR Relays
700-HR Multifunction Timer
Power indicator (green) (Flashes when Timer operates;
lit when Timer stops operating)
Operating mode display window
Operating mode selector
Select a mode from:
A, B, B2, C, D, E, J, and G (700-HR52, -HRV, and HRT 6)
A, E, B2, J, and B (800-HRS, -HRP, and -HRT4)
Output indicator (orange)
(Lit when energized)
Scale range display windows
Time unit display window
Time Range selector (select
one from 1.2, 3, 12, and 30 at
full scale.)
Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h)
Time setting
knob (set time)
700-HRC -HRM On-Delay Timer
Power indicator (green) (Flashes when Timer operates;
lit when Timer stops operating)
Output indicator (orange)
(Lit when energized)
Scale range display windows
Time unit display window
Time Range selector (select
one from 1.2, 3, 12, and 30 at
full scale.)
Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h)
Time setting
knob (set time)
700-HRF Twin Timer
OFF indicator (green)
Lit when the output is OFF.
OFF-time unit display
ON indicator (orange)
Lit when the output is ON.
OFF-time unit selector (select
one from sec, 10 s, min., 10 m, hrs, and 10 h)
Scale range display windows
ON-time setting knob (with orange pointer)
For ON-time setting
OFF-time setting knob (with green pointer)
For OFF-time setting
Time range selector (select
one from 1.2, 3, 12, and
30 at full scale.)
ON-time unit display
ON-time unit selector (select
one from sec, 10 s, min., 10 m, hrs, and 10 h)
700-HRY Star-Delta Timer
Star operation indicator
(green)
Delta operation indicator
(orange)
Time unit display
(sec. is fixed)
Scale range display windows
Time setting knob (for setting
star operation time)
Star-delta transfer time selector (select
one from 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s and 1.0 s)
Star operation time range selector
(select one from 6, 12, 60 and
120 at full scale.)
Star-delta transfer time unit display
700-HRQ True Off-Delay Timer
Scale range display windows
Output indicator (red)
Time setting knob (for setting OFF-delay time)
Time range selector (select one from 0.6, 1.2, 6, and 12
at full scale.)
True OFF-Delay time unit display
122
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications for Start, Gate, Reset Signal (Cat. Nos. 700-HR52, -HRT6, -HRV, -HRQR)
Start, Reset, and Gate signals are typically contact closures or signals from a solid-state sensor.
t <T
1
(R) Reset Signal
T
t
1
The reset signal is not required for normal operation. Reset can be accomplished by
Power toTiming Relay
removing power from the timing relay. To reset the timer without removing power,
a signal must be applied which resets the timing cycle and returns the output
contacts to their shelf state. The reset signal will override both the start signal and
gate signal. The reset signal can be either momentary or maintained.
Reset Signal
Timing Cycle
Timing Relay Output
(G) Gate Signal
t +t =T
2
1
t
t
The gate signal is not required for normal operation. The gate signal provides a
pause or retentive timing function. When the gate signal is applied the timing
cycle is momentarily interrupted. When the signal is removed, the timing cycle
resumes timing at the point the cycle was interrupted and will continue timing
until the time delay is completed or the gate signal is
2
1
Power toTiming Relay
Gate (pause)
Timing Cycle
Timing Relay Output
re-applied.
Contact Signal — Cat. Nos. 700-HR52, -HRT6, -HRQR
Contact closure provides signal to timer. A low energy signal is generated by the
700-HR timing relay. For optimum reliability, use contacts designed for low energy
switching (5V, 1 mA)
(Bul. 800F-X V, 800T-X V). No external voltage should be connected to the
contact signal.
R
S
G
5v, 1mA
Contact Signal — Cat. No. 700-HRV
For use in applications where it is not possible to use contacts designed for low
energy switching. Contact closure provides signal to timer. A signal is generated by
the 700-HR timing relay, and is the same potential as the supply voltage of the
timing relay. No external voltage should be connected to contact signal. 700-
HRV52TU24 supply voltage: 24...48V AC, 12...48V DC /
S
U
700-HRV52TA17 supply voltage: 100...240V AC, 100...125V DC.
U
+
(
)
(
)
+ 12...24V DC
COM
Solid-State Signal — Cat. Nos. 700-HR52, -HRT6
R
0.1mA
S
Timing relay is suitable for use with a 3-wire NPN 12...24V DC sensor. Supply
voltage potential of sensor must be the same as the supply voltage potential of the
timing relay. Permissible off-state leakage current from sensor: 0.01 mA max.
G
(
)
(+) 12...24V DC
COM
+ 12...24 V DC
COM
+ 12...24V DC
COM
Solid-State Signal — Cat. No. 700-HRV
S
S
Timing relay is suitable for use with a 3-wire NPN or PNP 12...24V DC sensor.
Supply voltage potential of sensor must be the same as the supply voltage
potential of the timing relay. Permissible off-state leakage current from sensor:
0.01 mA max.
(
)
COM
(
)
(+) 12...24V DC
COM
NPN Wiring Diagram
PNP Wiring Diagram
(+) 12...24V DC
Signal Specifications
Circuit impedance can be used to calculate the maximum wiring distance from the signal switch to the timing relay, for example.
Permissiblesignal-ONimpedance:1 k max.
Permissible signal-OFF impedance: 100 k min.
Circuit Impedance
Ω
Ω
Power-OFF Reset
Signal Duration
Min. power-off time: 0.1 s, Reset Voltage: 10% max. of rated voltage
Min. pulse width: 0.05 s
700-HR52
700-HRT6
700-HRV5
700-HRQR
Start
Reset
Gate
X
X
X
X
X
X
X
NA
X
Signal Options
NA
NA
NA
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
123
Relay and Timer Specifications
Timing Charts - 700-HR Relays
Mode A — ON-Delay
a. Needs continuous input power applied.
b. Timing is initiated by the leading edge of the start signal.
c. Contacts change state after timing is complete.
d. Additional start signals during timing don't reset timing or contacts.
e. When the input power is removed contacts return to shelf state.
Basic Operation
T
T
Power
Power
Start
Start
Output (N.C.)
Output (N.O.)
Output
Power LED
Mode B — Repeat Cycle, Off Start
a. Need continuous input power applied.
b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts.
c. For the first time period the contacts remain in their shelf state. When that time period is complete contacts change state for the same time period (time on = time off).
d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state.
Basic Operation
T
T
T
T
T
T
Power
Start
Power
Start
Output (N.C.)
Output (N.O.)
Power LED
Output
Mode B2 —Repeat Cycle On start
a. Need continuous input power applied.
b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts.
c. For the first time period the contacts change state. When that time period is complete contacts return to the shelf state for the same time period (time on = time off).
d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state.
Basic Operation
T
T
T
T
T
T
Power
Start
Power
Start
Output (N.C.)
Output
Output (N.O.)
Power LED
Mode C — Watchdog monitor (Trigger = Signal On/Off)
a. Need continuous input power applied.
b. Contacts change state immediately when start signal is applied or when start signal is removed (only if timing cycle was complete).
c. Timing is initiated at the leading edge of the start signal. After the first timing cycle is complete, timing is initiated by the trailing edge of the start signal.
d. At the end of the time period contacts return to the shelf state.
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.
f. When the input power is removed contacts return to the shelf state.
t<T
T
t
T
T
Basic Operation
T
Power
Start
T
Power
Start
Output (N.C.)
Output (N.O.)
Power LED
Output
124
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Mode D — Off-Delay (Trigger = Signal Off)
a. Need continuous input power applied.
b. Contacts change state immediately when start signal is applied.
c. Timing is initiated by the trailing edge of the start signal.
d. At the end of the time period contacts return to the shelf state.
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.
f. When the input power is removed contacts return to the shelf state.
Basic Operation
t
T
T
t<T
Power
Start
Power
Start
Output
Output (N.C.)
Output (N.O.)
Power LED
Mode E — One-Shot (Trigger = Signal On) 700-HR52, -HRV, and -HRT6
a. Need continuous input power applied.
b. Timing is initiated by the leading edge of the start signal.
c. Contacts change state immediately when start signal is applied.
d. At the end of the time period contacts return to the shelf state.
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.
f. When the input power is removed contacts return to shelf state.
Basic Operation
t<T
t
T
T
T
Power
Power
Start
Output (N.C.)
Output (N.O.)
Power LED
Start
Output
Mode E — One-Shot (Trigger = Power On) 700-HRS, -HRP, and -HRT4
a. Need continuous input power applied.
b. iming is initiated when the input power is applied.
c. At the end of the time period contacts return to the shelf state.
d. Relay timing is reset when input power is removed.
Basic Operation
t<T
T
T
Power
Power
Timed Output (N.C.)
Output
Timed Output (N.O.)
Power LED
Mode G — Watchdog Monitor (Trigger=Signal ON/OFF)
a. Need continuous input power applied.
b. Timing is initiated by the landing edge of the start signal.
c. After the first timing cycle is complete the contacts change state and timing is initiated by the trailing edge of the start signal.
d. At the end of the time period the contacts return to the shelf state.
e. Relay timing is reset when additional start signals are applied while the relay is timing.
f. When the power is removed contacts return to the shelf state.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
125
Relay and Timer Specifications
Mode J — Delayed One-Shot (Trigger = Power On)
a. Need continuous input power applied.
b. No start signal applied.
c. Timing is initiated when input power is applied.
d. Contacts change state after the timing for a fixed time of 1s +/-0.5s
e. At the end of the 1 sec period the contacts return to the shelf state.
f. When the input power is removed contacts return to the shelf state.
Basic Operation
T
Power
T
1s ±±.5s
Power
Output (N.C.)
1s ±±.5s
Output (N.O.)
Power LED
Output (N.O.)
Power LED
Mode Star-Delta
a. Need continuous input power applied.
b. No start signal required. Timing is initiated when input power is applied.
c. Star ouput contact changes state when input power is applied.
d. After timing is complete star output contact returns to the shelf state then both the star & delta contacts remain in shelf states until transfer time setting is complete.
e. Delta output contact changes state after transfer time is complete.
f. Instantaneous contact changes state when input power is applied.
g. All contacts return to the shelf state when input power is removed.
Basic Operation
t
1
t
2
Power
t
1
t
2
Output (N.C.)
Power
Output (N.O.)
Instantaneous Output
Output 8-5,
Output 8-6,
LED
LED
Output 8-5,
Output 8-6,
LED
LED
Mode True Off-Delay (Trigger = Power Off)
a. Continuous input power is NOT required.
b. No start signal applied.
c. Contacts change state immediately when input power is applied.
d. Timing starts when input power is removed.
e. At the end of the time period contacts return to the shelf state.
f. Relay timing is reset when input power is reapplied while the relay is timing. Contacts remain in energized state.
t<T
T
t
T
Basic Operation
Power
T
Output (N.C.)
Power
Output
Output (N.O.)
Relay On LED
Relay On LED
126
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-HR Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
127
Relay and Timer Specifications
700-HT Plug-in Timing Relay
•
•
•
•
•
•
Timing Relay (On-Delay or Off-Delay)
Rugged Pin Style Socket Mounting
10 A, DPDT Contact Ratings
0.1 s…30 min Fixed Timing Relay
0.1 s…3 min Single Adjustable Timing Relay
Single or Fixed Timing
Single Range Timing Relay with Pin Style Terminations
700
–
HT
2
2
A
A2
a
b
c
d
e
f
Catalog Number Explanation - 700-HT Relays
b
a
c
d
e
f
-
Type of Relay
Bulletin
Operating Mode
Number of Poles
Timing Range
Coil Voltage
Number
A– 0.1…10 s
B– 1.0…100 s
C– 0.1…10 min
D– 1.0…100 min
E – 0.1…10 hr
U12– 12V DC
1–On-delay
2–Off-delay
U24– 24V AC/DC, 50/60 Hz
U120– 120V AC/DC, 50/60 Hz
A2 – 240V AC, 50/60 Hz
HT -
700
2 - 2PDT
Tube Base Adjustable
Timing Relay
Wiring Diagrams
Operating Mode
U.S./Canada
International
On-Delay
Socket
700-HN125 or
700-HN100
700-HN100
Off-Delay
Socket
700-HT
700-HN126 or
700-HN101
700-HN101
DPDT 2-Pole — 2 Form C Contacts
128
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Fixed Timing Relays
700-HTF Fixed Timing Relays feature a plug-in tube base. Construction is the same as the 700-HT relay except that
the adjustment knob has been removed to help prevent unwanted tampering. The timing and output specifications
are identical to those of the 700-HT relay. Setting time will be 5ꢀ of the time ordered.
700
–
HTF
2
2
025
S
A2
a
b
c
d
e
f
g
Catalog Number Explanation - 700-HTF Relays
b
a
c
d
e
f
g
-
Type of Relay
Bulletin
Operating
Number of
Timing Range
Timing Units
Coil Voltage
Number
Mode
Poles
001…999 –
The three digit code represents a numeric
value with one decimal place. For
example: code 001 is 0.1, code 025 is 2.5,
and code 999 is 99.9
U12– 12V DC
S –Seconds
M –Minutes
H –Hours
1–On-delay
2–Off-delay
U24– 24V AC/DC, 50/60 Hz
U120– 120V AC/DC, 50/60 Hz
A2 – 240V AC, 50/60 Hz
HTF-
700
2 - 2PDT
Tube Base Fixed Timing
The acceptable range for each time unit is
Relay
listed below:
Seconds - 001…999
Minutes - 001…999
Hours - 001…100
Socket and Retainer Clip Reference
Relay Type
Socket Cat. No.
700-HN100
700-HN125
700-HN101
700-HN126
Retainer Clip Cat. No.
700-HN110
Not Required(1)
700-HT12
700-HT22
700-HN110
Not Required(1)
(1) Design of these sockets holds the relays securely and does not require retainer clips.
Accessories - 700-HT Relays
Description
Pkg. Qty. Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) 10
700-HN100
700-HN125
and -HRM, -HRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style
Construction. 8-Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV
10
(Repeat Cycle) Timing Relays. Order must be for 10 sockets or multiples of 10. No retainer clip
required.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
129
Relay and Timer Specifications
Description
Pkg. Qty. Cat. No.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal
10
10
700-HN101
700-HN126
Construction. 11-pin for use with 3PDT 700-HA relays.
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style
Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing
10
10
700-HN110
700-N40
Relays(1)Secures relay in socket. Order must be for 10 clips or multiples of 10.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank
tags. Tags are peel-off with sticky backing for easy placement on relays.
Blank Identification Tags — contains 10 sheets of blank identification tags for customer
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
700-N41
(1) Refer to 700-HT Timing Relay, Socket, and Retainer Clip Reference Chart.
130
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HT
Cat. No. 700-HT…
Electrical Ratings
Cat. No. 700-HTF…
Pilot Duty Rating (1)
NEMA B300
10 A
Rated Thermal Current (Ith
)
250V IEC, 300V UL/CSA
Rated Insulation Voltage (Ui)
Make
Break
HP
Make
Break
HP
Inductive
Contacts
30 A
15 A
10 A
3 A
1/2 N.O. 1/3 N.C
1/2 N.O. 1/3 N.C
—
30 A
15 A
10 A
3 A
1.5 A
10 A
1/3
1/2
—
120V AC
240V AC
1.5 A
10 A
Resistive 28V DC
85…110% of Nominal Voltage at 50 Hz
85…110% of Nominal Voltage at 60 Hz
80…110% of Nominal Voltage at DC
Permissible Coil Voltage Variation
24V AC
2 VA
4 VA
AC 120V AC
Power Consumption
10%
4 VA
240V AC
DC
1.3 W
Design Specification/Test Requirements
Pole-to-Pole, same
circuit (VRMS)
1000V AC
2000V AC
Dielectric Withstand Voltage
Pole-to-Pole, different
circuits (VRMS)
Contact-to-Coil (VRMS)
2000V AC
100,000 minimum
1800/hr
Electrical Life Operations
Switching Frequency Operations
Coil Voltages
See product selection
Mechanical
Open Type (Guarded Terminal Sockets)
Degree of Protection
Mechanical Life Operations
Switching Frequency Operations
Timing
10 x 106
18,000/hr
Continuous
Duty Cycle
Repeat Accuracy
(constant voltage and temperature)
2% (Time Delay: 0.1…2 s)
1% (Time Delay: >2 s)
Repeat Accuracy
(variable voltage and temperature)
10%
5% (Time Delay: 0.1…2 s)
1% (Time Delay: >2 s)
—
Fixed Time Setting Accuracy
+5%
-50%
—
—
High End of Range
Scale Tolerance
Reset Time
Low End of Range
ON Delay
100 ms
40 ms
OFF Delay
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
131
Relay and Timer Specifications
Cat. No. 700-HT…
Cat. No. 700-HTF…
Environmental
–28…+65 °C (50 °C max., 240V AC coil)
Operating
Storage
(–18…+149 °F) (122 °F max., 240V AC coil)
Temperature
–55…+85 °C
(–67…+185 °F)
2000 m (6560 ft)
Altitude
Construction
Molded High Dielectric Material
Impact Resistant Dust Cover
Silver Cadmium Oxide
Insulating Material
Enclosure
Contact Material
Terminal Markings on Socket
In accordance with EN50 005
8- or 11-Pin Socket
(On = 8, Off = 11)
700-HN100, -HN125
700-HN101, -HN126
Sockets
CSA Certified, File 223833, UL Recognized, File E3125 Guide NLDX 2,UL Listed,whe used with 700-HN100, 700-HN101, 700-HN125,
and 700-HN126 Sockets, File No. E3125 Guide NLDX, CE Marked
Certifications
Standards
EN 61812-1, CSA 22.2 No. 14, UL 508
(1) See NEMA Ratings and Test Values on page 5.
Trigger Signal Cat. Nos. 700-HT
Contact closure provides signal to timer. A low energy signal is generated by the 700-HT timing relay. For optimum reliability, use
contacts designed for low energy switching (10V, 1 mA) (Bul. 800F-X__V, 800T-X__V). No external voltage should be connected
to the contact signal.
Timing Diagrams - 700-HT Relays
ON Delay
OFF Delay
132
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-HV Timing Relay
•
•
•
•
•
•
Repeat Cycle Timing Relay
10 A Contact Rating
DPDT
Pin Style Terminals
0.1 s…30 min.
Repeat Cycle Adjustable Timing
•
Two Timing Adjustments T1
≠
T2
Repeat Cycle Timing Relays with Pin Style Terminations with 2 Adjustments (T1
≠ T2)
Wiring Diagrams
U.S./Canada
Operating Mode
International
Repeat Cycle
700-HN125 or
700-HN100
700-HV Repeat Cycle Timing Relay DPDT 2-Pole — 2 Form C Contacts
Socket
700-HN100
700
–
HV
3
2
A
A
A2
a
b
c
d
e
f
g
Catalog Number Explanation - 700-HV Relays
b
a
c
d
e
f
g
-
Type of Relay
Bulletin
Operating
Number of
Timing Range
Timing Range
Coil Voltage
Number
Mode
Poles
OFF Time
ON Time
Code OFF Time — Type HV
A – 0.1…10 s
Code ON Time — Type HV
A 0.1…10 s
3 –Power ON
Repeat Cycle,
OFF Start
U12 –12V DC
B – 1.0…100 s
B 1.0…100 s
U24 –24V AC/DC, 50/60 Hz
U120 – 120V AC/DC, 50/60 Hz
A2 –240V AC, 50/60 Hz
HV – Tube Base Repeat
Cycle Timing Relay
700
2 - 2PDT
C – 0.1…10 min
D – 1.0…100 min
E –0.1…10 hr
C 0.1…10 min
D 1.0…100 min
E 0.1…10 hr
(RepeatCycle,
OFF/ON
Delay)
Socket and Retainer Clip Reference
Relay Type
Socket Cat. No.
700-HN100
Retainer Clip Cat. No.
700-HN110
Not Required(1)
700-HV
700-HN125
(1) Design of these sockets holds the relays securely and does not require retainer clips.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
133
Relay and Timer Specifications
Accessories - 700-HV Relays
Pkg.
Qty.
Photo
Description
Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) and - 10
700-HN100
HRM, -NRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-
Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV (Repeat Cycle) Timing
Relays. Order must be for 10 sockets or multiples of 10. No retainer clip required.
10
10
700-HN125
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are
peel-off with sticky backing for easy placement on relays.
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10
relays.
134
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HV Relays
Cat. No. 700-HV…
Electrical Ratings
Pilot Duty Rating‡
NEMA B300
10 A
Rated Thermal Current (Ith
)
Rated Insulation Voltage (Ui)
250V IEC, 300V UL/CSA
Make
Break
Inductive
Hp
Contacts
120V AC
30 A
15 A
10 A
3 A
1/2 N.O. 1/3 N.C.
240V AC
1.5 A
10 A
1/2 N.O. 1/3 N.C.
—
Resistive 28V DC
85…110 of Nominal Voltage at 50 Hz
85…110 of Nominal Voltage at 60 Hz
80…110 of Nominal Voltage at DC
Permissible Coil Voltage Variation
24V AC
2 VA
4 VA
AC
120V AC
240V AC
Power Consumption
10%
4 VA
DC
1.3 W
Design Specification/Test Requirements
Pole-to-Pole, same circuit (VRMS)
1000V AC
2000V AC
Pole-to-Pole, different circuits
(VRMS)
Dielectric Withstand Voltage
Electrical Life Operations
Contact-to-Coil (VRMS)
2000V AC
100,000 minimum
1800/hr
Switching Frequency Operations
Coil Voltages
See product selection
Mechanical
Degree of Protection
Mechanical Life Operations
Switching Frequency Operations
Timing
Open Type (Guarded Terminal Sockets)
10 x 106
18,000/hr
Continuous
Duty Cycle
Repeat Accuracy
(constant voltage and temperature)
2% (Time Delay: 0.1…2 s)
1% (Time Delay: >2 s)
Repeat Accuracy
(variable voltage and temperature)
10%
High End of Range
Low End of Range
+5%
-50%
Scale Tolerance
Reset Time
100 ms
Environmental
–28…+65 °C (50 °C max., 240V AC coil)
(–18…+149 °F) (122 °F max., 240V AC coil)
Operating
Storage
Temperature
–55…+85 °C
(–67…+185 °F)
Altitude
2000 m (6560 ft.)
Construction
Insulating Material
Enclosure
Molded High Dielectric Material
Impact Resistant Dust Cover
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
135
Relay and Timer Specifications
Contact Material
Silver Cadmium Oxide
Terminal Markings on Socket
In accordance with EN50 005
8-Pin Socket
Cat. No. 700-HN100, -HN125
Sockets
CSA Certified, File 223833; UL Recognized, File E3125; Guide NLDX 2; cULus Listed when used with 700-HN100 and 700-
HN125 sockets; CE Marked
Certifications
Standards
EN 61812; CSA 22.2 No. 14; UL 508
Timing Diagram- 700-HV Relays
Dimensions - 700-HV Relays
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.
700-HV Timing Relay
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Approx.
Shipping Wt.
Cat. No.
199-DR1
199-DR4
A
B
C
D
35
(1-3/8)
27
(1-1/16)
7.5
(19/64)
1.02
(1/64)
1.85 kg
(4.07 lbs.) (10/pkg)
35
(1-3/8)
27
(1-1/16)
15
(19/32)
2.3
(3/32)
3.68 kg
(8 lbs.) (5/pkg)
136
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Cat. No. 700-HN125
Wire Size: 2 x 2.5 mm2
Single Wire—Up to #12 AWG
Double Wire—2 x 2.5mm2 (#2-14 AWG…#2-20 AWG)
(Either Solid or Stranded)
Cat. No. 700-HN100
Panel Mounting
Double Wire—2 x 2.5mm2 (#2-14 AWG…#2-20 AWG)
(Either Solid or Stranded)
Strip Length: 9 mm (3/8 in) - Torque: 0.8 N•m (7 ib•in)
Strip Length: 9 mm (3/8 in) - Torque: 0.8 N•m (7 ib•in)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
137
Relay and Timer Specifications
700-HX Multi-Function Digital Timing Relay
•
•
•
•
Digital timing relay with LCD display
Socket- or panel-mounted (NEMA 4X/IP66)
5A, B300, SPDT contact ratings
10 Functions or modes
•
Environmentally friendly — flash memory, no battery
No. of
Pins
Photo
Operating Mode
Timing Range
Socket Type Contact Output
Input Voltage Cat. No.
A mode: Signal ON-Delay 1
A-1 mode: Signal ON-Delay 2
A-2 mode: Power ON-Delay 1
A-3 mode: Power On-Delay 2
B mode: Repeat Cycle 1
B-1 mode: Repeat Cycle 2
D mode: Signal OFF-delay
E mode: One Shot
100…240V AC 700-HX86SA17
0.000…9.999 s
0.000…99.99 s
0.000…999.9 s
0.000…9999 s
0.000…99 min 59 s
0.000…999.9 min
0.000…9999 min
0.000…99 hr 59
min
700-HN100
SPDT
8
24V AC
F mode: Cumulative
700-HN125
700-HX86SU24
12…24V DC
Z mode: On/Off duty
adjustable repeat cycle
S mode:stop watch
0.000…999.9 hr
0.000…9999 hr
toff: Flicker OFF start 1
ton: Flicker ON start 1
toff-1: Flicker OFF start 2
ton-1: Flicker ON start 2
Socket and Retainer Clip Reference
Timer Type
Socket Cat. No.
700-HN100
Retainer Clip Cat. No.
700-HN131
(1)
700-HX
700-HN108
Not Required
700-HN125
Not Required
(1) Design of socket holds the relay securely and does not require retainer clips.
Accessories - 700-HX Relays
Photo
Description
Pkg. Quantity
Cat. No.
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal
Construction. 8-Pin for use with 700-HX Timing Relays. Order ten or multiples of ten
10
700-HN100
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style
Construction. 8-Pin for use with 700-HX Timing Relays. Order must be for 10 sockets or
multiples of 10. No retainer clip required.
10
10
700-HN125
199-DR1
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
138
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Photo
Description
Pkg. Quantity
Cat. No.
Specialty Socket
10
10
700-HN108
8-pin backwired socket with solder terminals. For use with 700-HX Timing Relays.
Retainer Clip for Cat. Nos. 700-HN100 Sockets with all 700-HX Timing Relays
Secures timer in socket.
700-HN131
700-HN130
Note: Not required for installation
Frame Adapter
For flush or door mounting of all 700-HR and -HX timers.
1
1
Protective Cover
Helps prevent tampering of timing and mode settings. Provides a degree of protection against
water and dirt from entering the front of the relay. For use with all 700-HR and -HX timing
relays.
700-HN132
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
139
Relay and Timer Specifications
General Timer Functions- 700-HX Relays
Display Section
1. Key Protect Indicator (orange)
2. Control Output Indicator (orange)
3. Reset Indicator (orange)
Operation Key
4
8. Mode Key
5
6
(Changes modes and setting items)
1
2
3
8
9. Reset Key
7
(Resets present value and output)
10
11
4. Present Value Display (Main display)
(Character height: 12 mm, red *)
* Characters on models with screw terminals
can be switched between red, green, and orange.
9
10. Up Keys 1 to 4
Front View
11. Down Keys 1 to 4
12
5. Time Unit Indicators
Switches
(Color is same as present value display.)
(If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, these
indicators flash to indicate timing
12. Key-protect Switch
OFF
ON
(Enabled)
(Default setting)
(Disabled)
operation.)
6. Set Value Display (Sub-display)
(Character height: 6 mm, green)
7. Set Value 1, 2 Indicator (green)
Character Size for
Character Size
Present Value Display
for Set Value Display
12 mm
6 mm
140
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-HX Relays
Attribute
700-HX
Electrical Ratings
Pilot Duty Rating
NEMA B300
Rated supply voltage
Operating voltage range
100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p) max.)
85…110% of rated supply voltage
100…240V AC
24V AC/12…24V DC
100…240V AC
24V AC/12…24V DC
120V AC
4.3VA
3.4VA/1.7 W
3 A
Power consumption
Inrush Current
Make
5 A
30 A
240V AC
15 A
120V AC
3 A
Break
240V AC
1.5 A
Hp at 120V AC
Hp at 240V AC
1/4 Hp
1/3 Hp
Mechanical
Mounting Method
Display
Flush mounting, surface mounting, DIN mounting
Seven-segment, negative transmissive LCD;
Present value (red, 12 mm high characters);
Set value (green, 6 mm high characters)
Digits
Four digits
0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s, 0 min 00 s…99 min 59 s,
0.0…999.9 min, 0 hr 00 min…99 hr 59 min, 0.0 hr…999.9 hr, 0 hr…9999 hr
Time ranges
Timer
Timer modes
Output modes
Input signals
Input method
Start, reset, gate
Power reset
Elapsed time (Up), remaining time (Down), selectable
A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1, or tON-1
Start, reset
No-voltage input via:NPN transistor or switching of contact
Minimum input signal width: 1 or 20 ms (selectable)
Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode)
Inputs
SPDT contact output: 5 A at 250V AC, resistive load (cosine=1)
Minimum applied load: 10 mA at 5 V DC (failure level: P,reference value)
Control output
External Power Supply
Key Protect
No
Yes
Memory Backup
EEP-ROM (overwritten 100 000 times min), which can store data for 10 years min.
Power-ON start: +-0.01% +-50 ms max. (1)to be rated against set value
(1)
Signal start: +- 0.005% +-30 ms max. to be rated against set value
Accuracy of Operating Time and Setting Error (1)
Signal start at transistor output model: +- 0.005% +-3 ms max. (2)
If the set value is within the sensor waiting time (250 ms max.)
(1) The values are based on the set value.
(2) The value is applied for a minimum pulse width of 1 ms.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
141
Relay and Timer Specifications
Attribute
700-HX
Environmental
Installation environment
Ambient temperature
Ambient humidity
Storage temperature
Altitude, max
Setup category II, pollution degree 2 (as per IEC61010-1)
-10…+55 °C (14…141 °F ), Avoid freezing or condensation
25…85 %
-25…+65 °C (-13…149 °F ), Avoid freezing or condensation
2,000 m
Characteristics (1)
Insulation Resistance
Dielectric Strength
100 mΩ min.(at500VDC)
2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current- carrying
metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for 1 min between non-
continuous contacts
1.5 kV (between power terminals) for 100 to 240 VAC, 480V for 24VAC/12 to 24VDC, and
600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/
1 μs, 1-ns rise)
Noise Immunity
Static Immunity
8 kV (malfunction), 15 kV (destruction)
Vibration Resistance
Shock Resistance
Malfunction
10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min
2
Malfunction
98 m/s (approx. 10 G) each in three directions
Mechanical
10 million operations min. (under no load at 18 000 operation/hr)
100 000 operations min. (5 A at 250V AC, resistive load at 1800 operation/hr)
EN61812-1
Life Expectancy
Electrical
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
EN55011 Group1 class A
EN55011 Group1 class A
EMC
EN61812-1
Immunity ESD:
Immunity RF-interference:
EN61000-4-2: 4 kV contact discharge (level2) 8 kV air discharge (level3)
EN61000-4-3: 10 V/m
Enclosure Ratings
Weight
Panel surface:IP66 and NEMA Type 4 (indoors) (2)
Approx. 100 g
Certifications
Standards
CE Certified; cURus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked
EN61010-1, EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL 508
(1) More information in the 700-HX User Manual, publication 700-UM002.
(2) An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700-HX and installation pan.
142
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Timing Charts- 700-HX Relays
One-Shot
One-shot outputs can be set to
0.1s, 0.5 s, 1 s, 5 s, 10 s, or 20 s.
Sustained Output
Output Mode A Mode: Signal ON-Delay (Timer resets when power comes ON.)
Timing starts when the start signal goes ON.
Power
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained
or one-shot time period.
Start signal
Gate*
Reset
Basic Operation
Power
**
t
t
t
Start Signal
Input
Control output
Timing
Set value
UP
0
Output
Timing
diagram
Set value
*Output is instantaneous when setting is 0.
** Start signal input is enabled during timing.
DOWN
0
Output Mode A-1: Signal ON-Delay 2 (Timer resets when power comes ON.)
Timing starts when the reset input goes ON and is
reset when the start signal goes OFF.
Power
While the start signal is ON, the timer starts when
the power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained
or one-shot time period.
Start signal
Gate*
Reset
Basic Operation
Power
Control output
Set value
Start Signal
Input
Timing
UP
0
Timing
diagram
Output
Set value
*Output is instantaneous when setting is 0.
DOWN
0
Output Mode A-2: Power ON Delay 1 (Timer resets when power comes ON)
Power
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e.,
same function as the gate input).
Start signal
Gate *
Reset
The control output is controlled using a sustained
or one-shot time period.
Basic Operation
Power
Timing
Control output
Set value
Output
UP
0
Timing
diagram
*Output is instantaneous when setting is 0.
Set value
DOWN
0
Output Mode A-3 Power ON Delay 2 (Timer does not reset when power comes ON)
Timing starts when the reset input goes OFF.
Power
Start signal
The start signal disables the timing function (i.e.,
same function as the gate input).
Gate *
Reset
The control output is controlled using a sustained
or one-shot time period.
Basic Operation
Control output
Set value
Power
Timing
Sustained
Output
UP
0
Timing
diagram
*Output is instantaneous when setting is 0.
Set value
DOWN
0
Gate not included on any mode of this relay.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
143
Relay and Timer Specifications
Output Mode B: Repeat Cycle (Timer resets when power comes ON.)
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
Sustained Output
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Power
Basic Operation
Start signal
Power
Gate*
Reset
**
Start Signal
Input
Timing
Timing
Timing
Timing
Control output
Set value
UP
Output
0
Timing
diagram
Set value
DOWN
* Normal output operation will not be possible if the
set time is too short.
0
Set the value to at least 100 ms (contact output type).
** Start signal input is disabled diring timing.
Timing starts when the start signal goes ON.
One-Shot Output
Power
The control output is turned ON when time is up.
While the start signal is ON, the timer starts when the
power cones ON or when the reset input goes OFF.
Basic Operation
Start Signal
Power
Gate*
Reset
**
Start Signal
Input
Timing Timing
Timing Timing
Output
Control Output
* Normal output operation will not be possible if the
set time is too short.
Set the value to at least 100 ms (contact output type).
** Start signal input is disabled during timing.
Set Value
0
Set Value
UP
Timing
Diagram
0
DOWN
Output Mode B-1: Repeat Cycle 2 (Timer does not reset when power comes ON)
Timing starts when the start signal goes ON.
The status of the control output is reversed when
time is up (OFF at the start).
Sustained Output
While the start signal is ON, the timer starts when the
power comes ON or when the rest input goes OFF.
Power
Basic Operation
Power
**
Start signal
Start Signal
Input
Gate*
Reset
Timing
Timing Sustained
Control output
Output
Set value
UP
* Normal output operation will not be possible
if the set time is too short
Set the value to at least 100 ms (contact
output type).
** Start signal input is disabled during.
0
Timing
diagram
Set value
DOWN
0
Timing starts when the start signal goes ON.
One-Shot Output
The control output comes ON when time is up.
While the start signal is ON, the timer starts when
the power comes ON or when the reset input goes OFF.
Basic Operation
Power
Power
Start signal
**
Start Signal
Input
Gate*
Reset
Timing
Timing
Output
Sustaining
Control output
* Normal outout operation will not be possible if the
set time is too short.
Set the value to at least 100 ms (contact output type).
** Start signal input is disabled during timing.
Set value
UP
0
Timing
diagram
Set value
DOWN
0
Gate not included on any mode of this relay.
144
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Output Mode D: Signal OFF-Delay (Timer resets when power comes ON.)
The control output is ON when the start signal is
ON (except when the power is OFF or the reset
is ON).
The timer is reset when the time is up.
Power
Start signal
Basic Operation
Gate*
Reset
Power
**
Start Signal
Input
Control output
Set value
Timing
Output
UP
0
Timing
diagram
Set value
* Output functions only during start signal input
when setting is 0.
** Start signal input is enabled during timing.
DOWN
0
Output Mode E: Interval (Timer resets when power comes ON.)
Timing starts when the start signal comes ON.
The control output is reset when time is up.
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
Power
Start signal
Basic Operation
Gate*
Reset
Power
**
Start Signal
Input
Control output
Set value
Timing
UP
0
Timing
diagram
Output
Set value
DOWN
0
* Output is disabled when the setting is 0.
** Start signal input is enabled during timing.
Output Mode F: Cumulative (Timer does not reset when power comes ON)
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
Basic Operation
Power
Start Signal
Input
Timing
Timing
Sustained
Output
*Output is instantaneous when setting is 0.
Gate not included on any mode of this relay.
Z Mode
Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (ꢀ) set value. The set
value shows the ON duty (ꢀ) and can be set to a value between 0 and 100 (ꢀ). When the cycle time is 0, the output will always be OFF. When the
cycle time is not 0 and when ON duty has been set to 0 (ꢀ), the output will always be OFF. When ON duty has been set to 100 (ꢀ), the output will
always be ON.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
145
Relay and Timer Specifications
Z mode: ON/OFF-duty Adjustable Repeat Cycle
Timing starts when the start signal goes ON.
The status of the control output is reversed
when time is up (ON at start).
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
Power
Start signal
* Gate
Basic Operation
Power
**
Reset
Start signal
input
Timing
(cycle time)
Timing
(cycle time)
Control Output
Cycle time
Timing
ON duty (%)
Timing
ON duty (%)
ON duty setting
(%) ON time
0
UP
Output
Cycle time
*
Normal output operation will not be possible if the
set time is too short.
Timing
diagram
ON duty setting
(%) ON time
Set the value to at least 100 ms (contact output
0
DOWN
type).
** Start signal input is enabled during timing.
Output Mode S: Stop Watch (Timer resets when power comes ON)
The signal starts and stops timing.
Power
The display is held and timing is continued if the reset
or gate input is received during timing operation.
The timer resets if the reset or gate input is received
when the timing operation is stopped.
Start signal
Basic Operation
Gate/Reset
9999
Power
Set time
Start signal
input
UP
Timing
Gate/Reset
0
Set time
DOWN
0
*
Display
(for elapsed
time)
RST
*
flashes
Output
Note: Output is instantaneous when setting is 0.
Output Mode T OFF: Twin Timer OFF start
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
Sustained Output
Power
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
Start signal
* Gate
Basic Operation
Power
**
Reset
Start Signal
Input
Control Output
OFF Time
Timing
OFF
Timing
OFF
Timing
ON
Timing
ON
UP
ON Time
Output
Timing
diagram
0
OFF Time
* Normal output operation will not be possible if the
ON/OFF set time is too short. Set the value to at least
100 ms (contact output type).
DOWN
ON Time
0
** Start signal input is disabled during timing.
Gate not included on any mode of this Relay.
146
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Output Mode T ON: Twin Timer ON start
Sustained Output
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (ON at start).
Power
While the start signal is ON, the timer starts when
power comes ON or when the reset input goes OFF.
Start signal
* Gate
Basic Operation
Power
**
Reset
Start Signal
Input
Control Output
OFF Time
Timing
ON
Timing
ON
Timing
OFF
Timing
OFF
UP
ON Time
Output
Timing
diagram
0
OFF Time
* Normal output operation will not be possible if the
ON/OFF set time is too short. Set the value to at least
100 ms (contact output type).
DOWN
ON Time
0
** Start signal input is disabled during timing.
Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON)
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Power
Start signal
Gate
Basic Operation
Power
Reset
*
Start signal
input
Timing
OFF
Timing
ON
Timing
OFF
a
b
Control output
Output
OFF time
UP
(a + b = ON time)
* Start signal input is disabled during timing.
ON time
Note: Normal output operation will not be possible if
the set time is too short.
0
OFF time
DOWN
ON time
Set the value to at least 100 ms (contact output
type).
0
Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON)
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Basic Operation
Power
*
input
Start signal
Timing
ON
Timing
OFF
Timing
ON
a
b
Output
(a + b = OFF time)
* Start signal input is disabled during timing.
Note: Normal output operation will not be possible if
the set time is too short.
Gate not included on any mode of this Relay.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
147
Relay and Timer Specifications
Dimensions- 700-HX Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
14.3
7.5
63.7
48×48
44.8×44.8
60 min.
+0.6
−0
45
+0.6
−0
45
60 min.
15 min.
Cat. No. 700-HX…
Panel Cutout
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
(1.38)
27.0
(1.06)
7.5
(0.3)
1000
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
Terminal Arrangement
Internal circuit
Signal
Reset
4
1
5
8
3
2
6
7
0V
(–) (+)
Cat. No. 700-HX…
148
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
NEMA Industrial Relays
Product Overview
Bulletin No.
Type
700-P
700S-P
700-N
Heavy-duty control relay
Heavy-duty control relay
Industrial Relay
•
Contact cartridges convertible from N.O. to
N.C. and vice versa
NEMA A300 AC
•
•
•
•
•
Convertible contacts
Up to 600V AC & DC
Very long life
Timer & latch options
Mechanically linked
•
•
•
•
•
Convertible contacts
Up to 600V AC & DC
Very long life
Timer & latch options
Mechanically linked
•
•
•
•
•
•
24…250V AC coils
Pneumatic timing unit
Solid-state timing unit
Overlap contacts
Features
Logic reed contacts
Contact Form
2…12 poles, double break
Bifurcated double break
Bifurcated silver nickel
2…12 poles, double break
Bifurcated double break
Bifurcated silver nickel
2- or 4-poles
—
Contact Type
Contact Material
Electrical
Silver
Max. Current AC Resistive
10 A
10 A
10 A
—
10V, 50 mA
1 mA, 5V with 700-CPR
10V, 50 mA
1 mA, 5V with 700-CPR
Min. load
24…600V AC
6…600V DC
24…600V AC
6…600V DC
Coil Voltage
—
85…110% AC coils,
80…110% DC coils
85…110% AC coils,
80…110% DC coils
Coil Voltage Pickup
—
—
Dielectric Withstand
Reference
2640V
2640V
Electric Service Life (cycles)
Certifications
10 million at 10 A 120V AC
10 million at 10 A 120V AC
—
cULus, CE
cULus, CE
UL, CSA, CE
—
Sockets
DIN Rail, relay rail, or panel mount
151
DIN Rail, relay rail, or panel mount
151
Product Selection
172
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
149
Relay and Timer Specifications
Product Overview
Bulletin No.
Type
700-R
700-RTC
Sealed Switch
Solid-state Timing Relay
•
•
•
•
Hazardous location ratings
Long life in dirty environment
Timer and latch options
•
•
Timed and instantaneous contacts.
Sealed contacts for harsh environments and
hazardous locations.
Features
Switch 600V AC, 300V DC
Contact Form
Contact Type
2...8 Poles
—
—
—
Sealed Switch
Sealed Switch
Contact Material
Electrical
—
—
—
Max. Current AC Resistive
Min. load
5 A
1 mA, 5V
24...240V AC
24...250V DC
Coil Voltage
—
85...110% AC Coils
80...110% DC Coils
Coil Voltage Pickup
—
—
Dielectric Withstand
Reference
2640V
Electric Service Life (cycles)
Certifications
1.5 million at 5 A 120V AC
UL, CSA, CE
—
—
—
Sockets
Panel or rail mount
Timing Relay Information
Control Outputs:
Time Limit Instantaneous
—
Four output contacts
On-Delay
Off-Delay
Timing Operation Modes:
Time Range
—
—
0.05 s…64 min
24V AC
110…120V AC
220…240V AC
24V DC
Supply Voltage
Product Selection
—
120V DC
240V DC
176
181
150
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-P Industrial Relays
700-P — Direct Drive™ Convertible Contact Cartridge Relays
•
•
•
•
•
•
•
•
•
•
•
NEMA and IEC ratings
600V maximum AC/DC
Accessories for field installation: contact cartridges, adder decks, time delay, latching, surge suppressors, mounting strip
Contact Ratings: (10 A) 700-CP1, (20 A) 700-CPM, (35 A) 700-CPH, (Low Power) 700-CPR
For machine tool and other heavy-duty applications
Can accommodate ring tongue terminals
Integral DIN Rail mount on AC relays
Finger-safe protection standard
Factory supplied standard at 120V AC and 24V DC - user configurable for field assembly
Blank relays are available in all coil voltages for field custom configuration
Contact cartridge is convertible from N.O. to N.C. by simply turning cartridge over.
The 700/700DC-P family of Direct Drive Industrial Relays offers switching solutions ranging from 200 mA in Low Energy Circuits to 35 A in
Heavy Duty Circuits. All of the contacts can easily be changed from the standard N.O. to N.C. configuration. The relays can be accessorized to
meet the application needs with the use of time delayed contacts, mechanical latches and NEMA enclosures. All devices are available in the most
popular AC and DC control voltages. Combining different cartridges into one relay can yield a custom-tailored application solution. Relays are
available without contact cartridges in all of the available AC and DC coil voltages for maximum flexibility.
700/700DC-P relays use standard (10 A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact
reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances the relay’s ability
to break DC circuits. These relays can be configured with a maximum of 12 contacts (only 8 may be N.C.).
A Modular Approach to Control Circuit Solutions
The 700-P AC control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O.in either 2, 4, 8, or 12 pole
configurations with a 120 volt operating coil. Four pole relays are also available at 240 and 480 VAC and can have up to eight contacts added by
using adder decks. The 700DC-P control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O. in either 4 or 8
poles with a 24 volt operating coil. The 4 pole is also available with a 120 VDC operating coil.
For control relays that require different contact ratings or control voltages we offer a modular design that are easily field configurable. A base blank
relay (either AC or DC control), a variety of contact kits, adder decks, and operating coils can be used to make an infinite number of custom control
relay solutions.
•
Master Control 700-PMCKIT master control cartridges provide (20 A) switching capability with large single-contact pads on each side of
the spanner for twice the current rating to control heavy loads and provide for master control of a system. The cartridge also has the same
double-break design as the standard 700-P relay contact cartridge. Relays can be configured with up to a maximum of 12 contacts (only 8
may be N.C.). Time delay and latching attachments are compatible with master cartridges.
•
Heavy Duty Control 700-PHDKIT contact cartridges provide (35 A) switching capability through tandem contact cartridges. A jumper
allows two (20 A) master contact cartridges to be connected in parallel. A maximum of six poles can be configured in a relay, only four of
which can be normally closed. Time delay and latch attachments are available.
•
•
Low Energy Control Logic Reed 700-PLRKIT contact cartridges provide switching to 200 mA @ 30 VDC. These contacts are matched
with standard control (10 A) contact cartridges for low energy switching applications.
Overlapping Contact 700-POLKIT contact cartridges provide (10 A) switching capabilities with the same rating as the standard contact.
These cartridge used in pairs operate with the N.O. contact closing before the N.C. contact opens on pick-up and vice versa on the drop-
out.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
151
Relay and Timer Specifications
AC-Operated Relays - In-stock Contact Configurations
Contacts
Open Type, DIN Rail, or Relay Rail Mount (700-MP)
120V AC 240V AC 480V AC
Contact Arrangement
and Markings
Photo
N.O.(1)
4-Pole
Relay
0
700-P000A1
—
—
—
4-Pole
Relay
2
4
700-P200A1
700-P400A1
700-P800A1
700-P1200A1
—
4-Pole
Relay
700-P400A2
700-P400A4
8-Pole
Relay
8
—
—
—
—
12-Pole
Relay
12
(1) Factory assembled N.O. contacts can be easily to N.C. in the field.
DC-Operated Relays - In-stock Contact Configurations
Contacts
Open Type Relay Rail Mount (2)
Contact Arrangement
and Markings
Photo
24V DC
120V DC
Cat. No.
(1)
N.O.
Cat. No.
4-Pole
Relay
0
4
700DC-P000Z24
700DC-P400Z24
—
4-Pole
Relay
700DC-P400Z1
8-Pole
Relay
8
700DC-P800Z24
—
(1) Factory assembled N.O. contacts can be easily to N.C. in the field.
(2) For DIN Rail mounting, order Cat. No. 700-DRA.
152
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Base Blank Relay - Factory Assembled
Photo
Type of Control Circuit
Cat. No.
AC
700-P000⊗
DC
700DC-P000⊗
⊗
⊗
AC Coil Voltage Code
Hz
50
60
24
—
A24
110
A1
115-120
—
200-208
—
230-240
—
277
—
460-480
575-600
—
—
A4
—
A1
A20
A2
A27
A6
DC Coil Voltage Code
24
48
72
Z72
115-125
Z1
230-250
Z2
575-600
Z6
Z24
Z48
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
153
Relay and Timer Specifications
Master (20 A) and Heavy Duty (35 A) Contact Cartridge Options
Follow this process to order a relay that utilizes: 20 A master contact cartridges or 35 A heavy duty contact cartridges.
Base Blank Relay
Base Blank Relay
+
Cartridge Kit
+
Adder Decks
+
Coil
Type of Control Circuit
Cat. No.
AC
700-P000A1
DC
700DC-P000Z24
+
Contact Cartridge Kits
Continuous Carrying Current
[A]
Photo
Description
Contents
Cat. No.
Master Contact
Cartridge
AC Rating Twice NEMA
A600
4 Master Cartridges (Cat. No. 700-CPM)
20
35
700-PMCKIT
DC Rating NEMA N150 P600
4 Master Cartridges and two sets of jumper terminals, rating
label (makes two 35 A poles)
Heavy Duty Contact Kit
700-PHDKIT
+
Adder Decks
Do you have more than four circuits or more than two 35 A circuits in the relay?
Adder Decks Required
Cat. No.
Device Description
Additional Cartridge Kits Required
8 Pole Device
700-PB00
1 additional kit
700-PB00
700-PC00
(Qty 1 of each)
12 Pole Device
2 additional kits
EXAMPLE Heavy Duty circuit (35 A) application that requires 4 circuits and 240 AC control circuit:
•
•
•
•
Base Unit: Cat. No. 700-P000A1
Cartridge Kits: Cat. No. 700-PHDKIT - Qty 2 (Each kit makes two circuits)
Adder Deck: Cat. No. 700-PB00
Coil: Cat. No. PA254
IMPORTANT If required, see Operating Coils for coil selection.
154
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Logic Reed and Overlapping Contact Cartridge Option
Follow this process to order a relay that utilizes: low energy contact cartridges or overlapping late make or late break cartridges.
Base Blank Relay
Base Blank Relay
+
Cartridge Kit
+
Adder Decks
+
Coil
Type of Control Circuit
Cat. No.
AC
700-P000A1
DC
700DC-P000Z24
+
Contact Cartridge Kits
Continuous Carrying Current
[A]
Photo
Description
Contents
Cat. No.
Logic Reed Cartridge for 2 Logic Reed Cartridges (Cat. No. 700-CPR)
Low Energy Circuits
500 mA 150V AC
200 mA 30V DC
700-PLRKIT
150V AC 500 mA 25 VA
Max. 30V DC 200 mA
6W Max.
2 Standard Cartridges (Cat. No. 700-CP1)
10
10
Overlap Contact
Cartridges
Overlapping
4 Overlapping Cartridges (Cat. No. 700-CP11Z)
700-POLKIT
Used in pairs. N.O. contact
closes before N.C. contact
opens on pick-up and vice
versa on drop-out.
+
Adder Decks
Do you have more than four circuits or more than two 35 A circuits in the relay?
Adder Decks Required
Cat. No.
Device Description
Additional Cartridge Kits Required
8 Pole Device
700-PB00
1 additional kit
700-PB00
700-PC00
(Qty 1 of each)
12 Pole Device
2 additional kits
EXAMPLE Logic Reed and Overlapping Contact Cartridge Option:
•
•
•
•
Low Voltage Circuit 24V DC less than 200 mA
Base Unit: Cat. No. 700-P000A1
Cartridge Kits: Cat. No. 700-PLRKIT - Qty 1
Coil: Cat. No. PA254
IMPORTANT If required, see Operating Coils for coil selection.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
155
Relay and Timer Specifications
Accessories - 700-P Relays
Adder Decks
No. of N.O.
Contacts
Continuous Carrying
Current [A]
Photo
Description
Arrangement
Cat. No.
Second Deck (0-pole)
Second Deck (4-pole)
0
4
—
10
700-PB00
700-PB40
Third Deck (0-pole)
Third Deck (4-pole)
0
4
0
700-PC00
700-PC40
10
156
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Operating Coils
Bulletin 700-P Relays — Bulletin 700-PLL-PKLL Mechanical Latch Attachments
Bulletin 700DC-P
2…12-pole,
DC control
Bulletin 700-P, 2…12-pole, AC control
Coil
Bulletin 700-PLL–PKLL AC Mechanical Latch Attachment
Volts(2)
60 Hz
50 Hz
60 Hz 50 Hz DC
—
24
PA013
—
PA407
—
PL013
—
PL407
—
PM714
PM724
PM730
—
PD714
48
PD724
72
—
—
—
—
PD730
(3)
110
—
PA236
—
PL236
PD733 (100…110)
115…120(3)
PA236
—
PL236
—
—
—
—
PA322
—
—
PL322
—
—
—
—
—
—
—
—
—
—
—
—
—
110…115(1)
Bulletin 700-P
Operating Coil
115…125
120§
—
PM735
—
PD735
—
PA322
—
—
PL322
—
130…140
200…208
220…230
230…240
230…250
277
—
—
—
PA249
PA251
PA254
—
—
—
—
—
PA339
PA342
—
—
—
—
PL254
—
—
—
PM748
—
PD748
—
PA260
—
—
—
380
PA354
PA357
—
—
—
415
—
—
—
—
440…460
—
PA360
—
—
—
—
460…480
500
PA273
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bulletin 700-PL
Unlatch Coil and
Magnet Assembly
—
575…600
PA278
PD758
(1) This coil is optimized for 110…115V, 50 Hz applications and will operate satisfactorily at 120V, 60 Hz.
(2) Coils for AC relays cannot be used in DC relays and vice versa.
(3) This coil is optimized for 115…120V, 60 Hz applications and will operate satisfactorily at 110V, 50 Hz.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
157
Relay and Timer Specifications
Contact Cartridges (Convertible from N.O. to N.C. and N.C. to N.O.)
Continuous Carrying
Current [A]
Photo
Description
Arrangement
Pkg. Quantity
Cat. No.
Standard Contact Cartridge
AC Rating NEMA A600
DC Rating NEMA P600
10
1
700-CP1
AC Rating
10
5
Overlap Contact Cartridges
Overlapping
Used in pairs. N.O. contact closes
before N.C. contact opens on pick-
up and vice versa on drop-out. (1)
NEMA A600
DC Rating
2
1
700-CP11Z
700-CPM
NEMA P150
125V DC, 138 VA
Make and Break
Master Contact Cartridge
AC Rating Twice NEMA A600
DC Rating NEMA N150 P600
20
Maximum
150V AC
500 mA
200 mA
Logic Reed Cartridge for
Low Energy Circuits
150V AC 500 mA 25 VA Max.
30V DC 200 mA
1
700-CPR
Maximum
30V DC
6W Max. (2)
(1) Not Direct Drive
(2) The 700-CPR Logic Reed cartridge must be installed only in the 2nd deck (B1X - B4X, B1Y - B4Y position) or 3rd deck (C1X - C4X, C1Y - C4Y position) of the Bulletin 700 Type P relay. It is not recommended that the 700-CPR cartridge
be installed in the single deck (A1X - A4X, A1Y - A4Y position) because this may lead to improper operation.
158
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Electrically Held Relays — Typical Wiring Diagrams
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
159
Relay and Timer Specifications
Pneumatic Time-Delay Unit
•
•
•
•
•
•
Timing Range — 0.1…60 s
0, 2, or 4 instantaneous contacts
Two timed contacts — both ON Delay or both OFF Delay
Convertible from ON Delay to OFF Delay and vice versa
Standard contact cartridges rated NEMA A600 (AC) and P600 (DC)
Master contact cartridges rated 2X NEMA A600 (AC) and N150 P600 (DC)
Open Type
Without
No. of Timed Contacts (1)
Continuous Carrying Current
Enclosure(2)
Photo
Operating Mode
Arrangement
Timing Range
[A]
N.O.
N.C.
Cat. No.
10
20
700-PT
On-Delay
Off-Delay
1
1
0.1…60 s
700-PKT
(1) In addition to instantaneous cartridges on the relay
(2) Mounts on 4-pole Bulletin 700-P or -PK relay or 2-pole Bulletin 700-PH relay.
Mechanical Latch Units
Photo
Description
Arrangement
Continuous Carrying Current [A]
Cat. No.
No cartridge
700-PLL⊗
AC-Operated Latch Units
10
700-PLL11⊗
700-PKLL11⊗
700DC-PLL⊗
700DC-PLL10⊗
20
No cartridge
10
DC-Operated Latch Units
20
700DC-PKLL10⊗
⊗ AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PLL⊗
becomes Cat. No. 700-PLLA1.
Hz
50
60
24
110
A1
110-115 115-120 120
200-208 220-230 230-240 277
347
—
—
380
—
—
415
—
—
440-480 460-480 500
575-600
—
(1)
(2)
B24
A24
B11
—
—
—
—
—
—
—
—
A2
—
—
—
—
—
—
—
—
—
A1 (1)
B11(2)
—
(1) Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz.
(2) Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
⊗ DC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PLL⊗
becomes Cat. No. 700DC-PLLZ24.
24
48
64
72
115-125
230-250
575-600
Z24
Z48
—
Z72
Z1
Z2
Z6
160
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories
Relays per
Strip
Photo
Description
Pkg. Quantity
Cat. No.
4
8
5
5
5
700-MP4
Relay Rail
700-MP8
Simplifies panel layout. These indexed strips are easily cut to the
required length and bolted, riveted, or spot-welded in place. Relays are
installed adjacent to one another on the mounting strip with the
captive mounting screws provided. Rows of relays on Relay Rail form
their own wiring trough.
12
700-MP12
Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N,
700-R, 700-RTC
16
5
700-MP16
700-DRA
DIN Rail Adapter
Can be used with the following relays:
Bulletin 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC
1
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Type 1 Enclosure — Use for all Bulletin 700-P relays except 10- and 12-pole DC relays
1
1
700-N31
700-N39
or 6-pole DC Bulletin 700-PH relays.
Type 4/4X Enclosure — For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole
heavy duty relays.
Type 7 & 9 Enclosure — For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole
heavy duty relays. 1 conduit hub; top and bottom.
1
700-N33
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
161
Relay and Timer Specifications
Accessories
Photo
Description
Pkg. Quantity
Cat. No.
Mountingbehind
relay
1
1
700-N5
Surge Suppressors (RC Circuit) — Surge suppressors reduce the high
transient voltages generated when the coil circuit is opened. These suppressors
can be used with Bulletin 700-P, -PH, -PK, and -N relays, and other
electromechanical devices. They contain a resistor and capacitor. Maximum
ratings: 150V, AC or DC, 35 VA. Cat. No. 700-N5 requires 1 in. additional depth of
enclosure.
Mounting on coil
terminal
700-N24
Surge Suppressor
24…48V AC/DC
1
1
199-FSMA9
When the circuit to a DC operating coil is opened, the inductive energy stored in
the coil can generate very high transient voltages. With the addition of the
appropriate surge suppressor, the stored energy is absorbed and dissipated
limiting the voltage spikes. A surge suppressor is not required with AC 700-R or -
RM relays because the AC operating coil transients are suppressed by a full wave
rectifier connected to the coil.
50…120V AC/
DC
199-FSMA10
130…250V AC/
DC
1
1
199-FSMA11
199-FSMZ-1
Diode Surge Suppressor — for 6…300V DC voltage coils. Used on Bulletin 700-P, -PH, -PK, -N, -F,
and -R relays.
35 A Jumper Kit – CSA Approved, UL Listed
This 35 A Jumper Kit can be used with any Bulletin 700-P and -PK AC or DC relay, Time-Delay relay or
Latch Unit equipped with 20 A Master Cartridges. It does not require any additional panel space.
Jumper Kit terminals are designed for one #8 AWG wire or two #10 AWG wires. When connecting the
two 20 A Master Cartridges in parallel, it is important that they be the same configuration (Normally
Open or Normally Closed).
1
700-CPH
700-N3
Jumpers can be added to any contact cartridge location on a relay except the two center poles
because of the wide spacing. An adhesive label is included with each kit listing the contact ratings.
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) – For connection
Jumper – For
outer poles
between a middle pole and an outer pole on the left or right side of the relay.
50
Cat. No.
700-N3
Cat. No.
700-N4
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) – For connection
between two middle poles.
Jumper – For
middle poles
700-N4
Check Out Tool — Mechanically maintains the Bulletin 700-P, -PH, or -PK relay in the energized
position for troubleshooting purposes.
700-N23
1
Adapter Plate — Simplified relay conversion. Allows you to use the existing mounting holes when
you replace a Bulletin 700-B, -BR, -BX, or -D relay with a Bulletin 700-P, -PH, or -PK relay.
700-N34
162
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
IP 2X Finger-Safe Cover Accessories
Photo
Description
Pkg. Quantity
Cat. No.
Top Covers (Covering Top Level Contact Screws)
IP2X Top Cover for 700-P
1
1
1
1
1
700-PFSC
Timer Top Cover Kit
700-PFSTC
700-PFSLCK
700-PFSKTC
700-PFSKLCK
Latch Top Cover Kit (for Relays with Mechanical Latch Attachment)
Timer Top Cover Kit, (for Master Cont. Relays with Pneumatic Timer)
Latch Top Cover Kit (for Master Cont. Relays with Mechanical Latch)
Deck Covers (Covering all terminals not on top deck, only for multi-deck relays)
IP2X Deck Cover for all AC & DC Relays in the 700P Range
Coil Covers
1
700-PFSDEK
IP2X Coil Cover for all AC Relays in the 700P Range
IP2X Coil Cover for all DC Relays in the 700P Range
1
1
700-PFSACC
700-PFSDCC
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
163
Relay and Timer Specifications
Specifications - 700-P Relays
Type
Standard Cartridge
700-P
Master Cartridge
700-PMCKIT
Heavy duty
700-PHDKIT
Bulletin No.
Electrical
Contact Rating Continuous
10 A @ 600V AC ; 5 A @ 600V DC
NEMA A600
20 A @ 600V AC; 10 A @ 600V DC
2 x NEMA A600
35 A @ 600V AC; 20 A @ 600V DC
2 x NEMA A600
AC
Ratings Make/Break
DC
NEMA P600
N150 P600
N150 P600
3 Hp @ 240V AC - N.O.
2 Hp @ 240V AC - N.O./N.C.
1 Hp @ 120V AC - N.O./N.C.
20 A Resistive Heating to 600V AC
20 A Tungsten Lighting Load to 480V AC
Cartridge Cat. No. 700-CPM
Volts DC
5 Hp @ 240V AC - N.O.
3 Hp @ 240V AC - N.O./N.C.
Additional Contact Ratings for
AC single-phase loads
—
2 Hp @ 120V AC - N.O./N.C.
35 A General Use At 0.75 PF to 600V AC
35 A Tungsten Lighting Load to 480V AC
DC Current Ratings Make/Break
Cartridge Cat. No. 700-CP1
Cartridge Cat. No. 700-CPH
Contacts in
Series
24
64
125
250 500
138 135
600
24
64
125
250
500
600
24
64
125
250
500
600
480
W
480
W
275
W
120
W
W
W
DC Switching
Inductive Load
1
5 A 2.2 A 1.1 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A
2
10 A 10 A 5 A
2 A
.7 A .5 A 20 A 10 A 5 A
2 A
.7 A .5 A 20 A 10 A 5 A
2 A .7 A .5 A
3 A 1.5 A 1.0 A
3
—
—
—
—
7 A
3 A 1.5 A 1.0 A
—
—
15 A 7 A
3 A 1.5 A 1.0 A
—
—
15 A 7 A
4
10 A 5 A 2.5 A 1.5 A
85…110%
80…110%
85…115%
60 Hz
20 A 10 A 5 A 2.5 A 1.5 A
20 A 10 A 5 A 2.5 A 1.5 A
85…110%
AC
85…110%
80…110%
85…115%
DC
80…110%
Coil Voltage Range
Battery
85…115%
50 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Inrush
132VA (2)
19.3VA (2)
138VA (2)
19VA (2)
12.7VA (2)
12.7VA (2)
15.6VA (2)
5.5VA (2)
132VA (2)
19.3 VA (2)
138VA (2)
19VA (2)
132VA (2)
19.3VA (2)
138VA (2)
19VA (2)
AC
DC
Coil
Sealed
Consumption
Inrush
12.7VA (2)
12.7VA (2)
12.7VA (2)
12.7VA (2)
Sealed
Inrush
15VA (2)
5.4VA (2)
5VA (2)
5.4VA (2)
15.6VA (2)
5.5VA (2)
15VA (2)
5.4VA (2)
15.6VA (2)
5.5VA (2)
PLL - PKLL
AC Latch Unit
Sealed
Unlatch
Intermittent
PT – PKT
PLL–PKLL
35VA (2)
35 W (2)
35VA (2)
35 W (2)
75 ms
—
—
—
—
PLL - PKLL
DC Latch Unit
Reset Time
75 ms
Minimum Pulse
75 ms
75 ms
Mechanical
Pickup
AC – 10…20 ms / DC – 30…50 ms
AC – 10…20 ms / DC – 20…33 ms
AC – 10…20 ms / DC – 30…50 ms
AC – 10…20 ms / DC – 20…33 ms
10 million operations
AC – 10…20 ms / DC – 30…50 ms
AC – 10…20 ms / DC – 20…33 ms
Operating Time
Mechanical Life
Dropout
Construction
Up to 6 Poles, Convertible to N.O. or N.C.
(4 N.C. Maximum)
Contact Arrangement
Up to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum)
Contact Material
Mounting
Silver Nickel
Silver Cadmium Oxide
Silver Cadmium Oxide
Panel, Strip Mount, or DIN Rail Horizontal Mounting Recommended
Environmental
Operating (1)
Storage
–20…+65 °C (–4…+149 °F)
–40…+65 °C (–40…+149 °F)
–20…+65 °C (–4…+149 °F)
–20…+65 °C (–4…+149 °F)
–40…+65 °C (–40…+149 °F)
Temperature
–40…+65 °C (–40…+149 °F)
Wire Terminations
#18 AWG…(2) #12 AWG
Wire size per UL/CSA
Tightening Torque
Standards Compliance
Certifications
8…12 lb•in (0.9…1.4 N•m)
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS
(1) Temperature inside the panel.
(2) Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor.
164
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
International Symbol for Mechanically Linked Contacts
Dimensions - 700-P Relays with standard, master contact, or heavy-duty contact cartridge
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
103.43 (4-5/64)
— 171.68 (6-49/64)
1/2
2.77
(7/64)
2.77
(7/64)
2- and 4-pole 700-P Relay
Approx Shipping Weight: AC – 0.68 kg (1.5 lb), DC – 1.34 kg (2.95 lb)
2- and 4-pole 700-P with Pneumatic Time Delay Attachment
Approx Shipping Weight: AC – 0.85 kg (1.88 lb), DC – 1.5 kg (3.33 lb)
AC 136.75 (5-25/64)
171.68 (6-49/64)
2.77
(7/64)
2.77
(7/64)
6- and 8-pole 700-P Relay with one -PB adder deck
Approx Shipping Weight: AC – 0.79 kg (1.75 lb), DC – 1.45 kg (3.20 lb)
700-P Relay with Mechanical Latch Attachment
Approx Shipping Weight: AC – 0.97 kg (2.13 lb), DC – 1.62 kg (3.58 lb)
AC 136.75 (5-25/64)
Cat. No. 7±±
#8 Screws
(Captive)
2.77
(7/64)
700-P Relay, up to 12 poles with -PB and -PC adder decks
Approx Shipping Weight: AC – 1.02 kg (2.25 lb), DC – 1.68 kg (3.7 lb)
Relay Rail for 700-P, -N, -NM, -R, -RM, -RT, -RTA Relays
Secure the mounting strip with two screws at each end relay position.
Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions.
Alternate between upper and lower horizontal slots.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
165
Relay and Timer Specifications
178.60
(7-1/32)
AC – 170.49 (6-23/32)
DC – 187 (7-25/64)
700-PS
Timer
Cat. No. 700-N31, Type 1 Enclosure for
700-P, -RTC Relays
Approximate Shipping Weight: 1.26 kg (2.8 lb)
700-PS Timer Mounted on a 700-P Relay
Approximate Shipping Weight: AC – 0.68 kg (1.5 lb) without 700-PS,
DC – 1.34 kg (2.9 lb) without 700-PS
12.5
6.2
(15/64)
1.0
(0.04)
50
(1-63/64)
(1/2)
5.2
(13/64)
3.98
(0.16)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(39-3/8)
2.25
(0.09)
0.5
(.02)
(0.3)
0.5
(.02)
Cat. No. 199-DR1 DIN Mounting Rail Series B
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes
DIN Rail Adapter
166
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700S-P and 700S-PK — Heavy-Duty Safety Control Relays
•
•
•
•
•
•
•
Mechanically linked contacts meet IEC 947-5-1-L
2…12 poles – all mechanically linked
Red cover for easy identification of safety circuits
Tamper resistant cover helps prevent changes which could jeopardize safety
IEC mechanically linked contacts symbol displayed on front
Visual indication of contact state
Ideal for use in safety circuits
700S-P (10 A) Safety Control Relays — AC and DC Coil Voltages
AC Coils
Contacts
24V DC Coils
Open Type Panel Mount Relay Rail Mount
Open Type Panel Mount Relay Rail Mount
Open Type DIN Rail Mount
N.O.
3
N.C.
1
Cat. No.
Cat. No.
700S-DCP310Z24
700S-DCP220Z24
700S-DCP710Z24
700S-DCP620Z24
700S-DCP530Z24
700S-DCP440Z24
700S-DCP350Z24
700S-DCP1020Z24
Cat. No.
700S-P310
700S-P220
700S-P710
700S-P620
700S-P530
700S-P440
700S-P350
700S-P1020
700S-DCP310DZ24
2
2
700S-DCP220DZ24
700S-DCP710DZ24
700S-DCP620DZ24
700S-DCP530DZ24
700S-DCP440DZ24
700S-DCP350DZ24
700S-DCP1020DZ24
7
1
6
2
5
3
4
4
3
5
10
2
(1)
⊗
AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: Cat. No. 700S-P310
becomes Cat. No. 700S-P310A1 for a 120V AC coil.
[V]
24
115-120
230-240
460-480
60 Hz
A24
A1
A2
A4
IEC 947-5-1 Annex L has 2 requirements for a relay to meet for mechanically linked contacts:
1.) If a N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test.
2.) If a N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test.
700S-P and 700S-DCP relays meet these requirements including the 2500V impulse test.
The relays shown on this page are shipped from the factory with the 700-CPS safety cartridge installed and cannot be converted to N.O. or N.C. in the Field.
(1) For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
167
Relay and Timer Specifications
700S-PK (20 A) Safety Control Relays
Contacts
Coil Voltage
Cat. No.
N.O.
N.C.
7
1
2
3
4
5
2
1
1
2
3
4
5
2
1
110V AC
110V AC
110V AC
110V AC
110V AC
110V AC
110V AC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
700S-PK710A1
6
700S-PK620A1
5
700S-PK530A1
4
700S-PK440A1
3
700S-PK350A1
10
3
700S-PK1020A1
700S-PK310A1
7
700S-DCPK710Z24
700S-DCPK620Z24
700S-DCPK530Z24
700S-DCPK440Z24
700S-DCPK350Z24
700S-DCPK1020Z24
700S-DCPK310Z24
6
5
4
3
10
3
168
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700S-P Relays
Type
700S-P
Electrical
10 A @ 600V AC
5 A @ 600V DC
Contact Rating Continuous
AC
NEMA A600
NEMA P600
10V, 50 mA
Volts DC
Ratings Make/ Break
DC
Minimum Contact Switching Ratings
Contacts in Series
24V
5 A
64V
2.2 A
10 A
—
125V
1.1 A
5 A
250V
0.55 A
2 A
500V
600V
0.2 A
0.5 A
1.0 A
1.5 A
DC
1
2
3
4
0.24 A
0.7 A
1.5 A
2.5 A
Switching
Inductive Load
10 A
—
7 A
3 A
—
—
10 A
5 A
1.5 million operations at 10A break at 120V AC
14 million operations at 1A break at 120V AC
6 million operations at 1A break at 24V DC
Contact Electrical Life— Resistive Loads
AC
85…110%
80…110%
85…115%
Coil Voltage Range (1)
DC
Battery Charging
Coil Consumption
AC
50 Hz
132 VA
19.3 VA
60 Hz
138 VA
19 VA
Inrush
Sealed
Inrush
Sealed
12.7 W
12.7 W
DC
Mechanical
Mechanically Linked Contacts
All contacts are mechanically linked per IEC 947- 5-1 annex L for 2 to 12 poles
AC – 10…20 ms
DC – 30…50 ms
Pickup
Operating
Time
AC – 10…20 ms
DC – 20…33 ms
Dropout
Mechanical Life
10 million operations
Construction
2…12 Poles, Double Break Contacts
N.O. or N.C. (8 N.C. Maximum)
Contact Arrangement
Contact Material/Design
Mounting
Silver Nickel/Bifurcated
Panel mount or mount on 700-MP Relay or DIN Rail Horizontal Mounting Recommended
Environmental
Operating Temperature (2)
Storage Temperature
Wire Terminations
Wire size per UL/CSA
Tightening Torque
-20…+65 °C (-4…+149 °F)
-40…+65 °C (-40…+149 °F)
#18 AWG…(2) #12 AWG
8…12 lb•in (0.9…1.4 N•m)
Standards Compliance
Certifications
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS
(1) Coil voltage required for proper operation (percent of rated coil voltage).
(2) Temperature inside the panel.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
169
Relay and Timer Specifications
Specifications - 700S-PK Relays
Type
700S-PK
Electrical
20 A @ 600V AC
10 A @ 600V DC
Contact Rating Continuous
AC
NEMA A600
NEMA P600
Ratings Make/ Break
DC
3 Hp @ 240V AC - N.O.
2 Hp @ 240V AC - N.O./N.C.
Additional Contact Ratings for AC Single-Phase Loss
1 HP @ 120V AC - N.O./N.C.
20 A resistive heating to 600V AC
20 A Tungsten lighting load to 480V AC
DC Current Ratings Make/Break
Contacts in Series
Cartridge Cat. No. 700-CMS
Volts DC
24V
10 A
20 A
—
64V
5 A
125V
2.2 A
5 A
250V
0.55 A
2 A
500V
0.24 A
0.7 A
1.5 A
2.5 A
600V
0.2 A
0.5 A
1.0 A
1.5 A
1
DC
Switching
2
10 A
15 A
20 A
3
7 A
3 A
4
—
10 A
5 A
85…110%
80…110%
85…115%
AC
Coil Voltage Range (1)
DC
Battery Charging
50 Hz
132 VA
19.3 VA
60 Hz
138 VA
19 VA
Coil Consumption
AC
Inrush
Sealed
Inrush
Sealed
12.7 W
12.7 W
DC
Mechanical
All contacts are mechanically linked per IEC 947-5-1 annex L
for 2 to 12 poles
Mechanically Linked Contacts
AC – 10…20 ms, DC – 30…50 ms
AC – 10…20 ms, DC – 20…33 ms
Pickup
Operating Time
Dropout
Construction
2…12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum)
Silver Cadmium Oxide
Contact Arrangement
Contact Material/Design
All contacts, are mechanically linked per IEC 947-5-1 Annex L for 2 to 12 poles
Panel mount or strip mount recommended
Mechanical (Mechanically-Linked Contacts)
Mounting
Environmental
Operating Temperature (2)
Storage Temperature
Wire Terminations
Wire size per UL/CSA
Tightening Torque
-20…+65 °C (-4…+149 °F)
-40…+65 °C (-40…+149 °F)
#18 AWG…(2) #12 AWG
8…12 lb•in (0.9…1.4 N•m)
Standards Compliance
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1
Certifications
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS
(1) Coil voltage required for proper operation (percent of rated coil voltage).
(2) Temperature inside the panel.
170
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700S-P Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
103.43 (4-5/64)
AC 136.75 (5-25/64)
1/2
2.77
(7/64)
2.77
(7/64)
2- and 4-pole 700S-P Relay
Approximate Shipping Weight: AC – 0.68 kg (1.5 lb), DC – 1.34 kg (2.95 lb)
6- and 8-pole 700S-P Relay
Approximate Shipping Weight: AC – 0.79 kg (1.75 lb), DC – 1.45 kg (3.20 lb)
170.10 (6-45/64)
Cat. No. 7±±
#8 Screws
(Captive)
2.77
(7/64)
10- and 12-pole 700S-P (Captive)
Relay Rail
Approximate Shipping Weight: AC – 1.02 kg (2.25 lb), DC – 1.68 kg (3.7 lb)
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
DIN Rail
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
171
Relay and Timer Specifications
700-N Industrial Relays
•
•
•
•
•
•
•
•
Contact cartridges convertible from N.O. to N.C. and vice versa
NEMA A300 AC
24…250V AC coils
Pneumatic timing unit
Solid-state timing unit
Overlap contacts
Logic reed contacts
4-…8-pole
AC-Operated Relays
Contacts
N.O.
Open Type
Cat. No.
Photo
Contact Arrangement
N.C.
4
—
700-N400⊗
Type NM Relay
2 Poles§
2
—
700-NM200⊗
⊗AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-N200⊗
becomes Cat. No. 700-N200A24 for 24V 60 Hz. For other coil voltages, contact your local Rockwell Automation sales office or Allen-Bradley
distributor.
[V]
24
110
120
208
220
240
50 Hz
60 Hz
—
A1
—
A1
—
A2
—
A2
A24
—
A20
—
•
•
NORMALLY CLOSED CONTACTS: Listed relays are supplied with all contacts normally open. These contacts can be readily converted to normally closed in
the field.
OVERLAP CONTACTS: Overlap contacts (normally open contact closes before the normally closed contact opens) can be supplied. See for information on
kits for field installation of overlap contact cartridges.
IMPORTANT
•
•
Location of contacts in 2-pole relays
Permanent Magnet Latch AC Relay. Minimum Operating Time - Type NM - For reliable operation, power to the latch circuit must be maintained for a
minimum time of 75 milliseconds and power to the unlatch circuit must be maintained for minimum time of 50 milliseconds.
172
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Operating Coils
700-N Relay • 2-…8-Pole
Photo
Coil Voltage
60 Hz
50 Hz
84AB28
84AB86
—
24
84AB27
84AB01
84AB86
84AB113
84AB06
84AB83
110
120
208
220
240
—
84AB83
—
700-NT Pneumatic Timing Unit
Timed
Contact
Contacts
Arrangement
Open Type
Photo
Description
N.O.
N.C.
Cat. No.
ON-Delay mode is
standard. Timer is
easily converted to
OFF-Delay mode.
Timing Unit Only
(for 700-N, 2…4-pole)
1
1
700-NT
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
173
Relay and Timer Specifications
Specifications - 700-N Relays
Attribute
Bul. 700-N
Bul. 700-NT
Electrical Ratings
Rated Thermal Current Ith
Rated Insulation Voltage
Contact Rating
10 A
300V
10 A @ 300V AC, NEMA A300
AC
DC
85…110%
80…110%
—
—
Coil Voltage Range
Coil Consumption
50 Hz
AC
60 Hz
—
—
—
Inrush
Sealed
120 VA
24 VA
133 VA
20 VA
AC
Mechanical
—
—
Pickup
14 ms
13 ms
—
Max. Operating Time
Drop Out
—
Timing Range
Repeat Accuracy
Reset Time
0.2…60 s
15% of setting
75 ms
—
—
On-Delay — convertible to OFF Delay, up to 2 poles
convertible to N.O. or N.C.
Timing Mode
—
Construction
Contact Arrangement
Contact Material
Mounting
Up to 8 Poles, Convertible to N.O. or N.C.
Silver
—
Silver
Panel or strip mount Horizontal mounting recommended
On relay only
Environmental
Operating
Storage
–20…+40 °C (–4…+104 °F)
Ambient Temperature (Outside
Enclosure)
–40…+60 °C (–40…+140 °F)
Operating Temperature Rise (Inside Enclosure)
Wire Terminations
+25 °C Max
—
Wire size per UL/CSA
Tightening Torque
#18 AWG…(2) #12 AWG
8…12 lb•in. (0.9…1.4 N•m)
Standards Compliance
UL 508, CSA C22.2, No. 14
Certifications
cULus Listed (File No. E14840, Guide NKCR/NKCR7)
174
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700-N Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Type of Relay
No.
of
Poles
Open Type
Approx
. Ship.
Wt. kg
(lbs.)
Type 1
General Purpose Enclosure
Approx
Without Enclosure
. Ship.
Wt. kg
(lbs.)
Drawing
Number
A
B
High
C
D
A
Wide
B
C
D
E
Wide
Deep
High
Deep
185.74 103.19
57.15
88.90
82.55
79.38
0.68
107.95
146.05
85.73
1.59
700
700
700
700
2…4
6…8
2…4
2…4
1
2
3
3
(7-5/
16)
(4-1/
16)
(2-1/4) (3-1/2) (3-1/4) (3-1/8) (1-1/2) (4-1/4)
(5-3/4) (3-3/8) (3-1/2)
N
N
106.36
(4-3/
16)
112.71
(4-7/
16)
57.15
(2-1/4) (3-1/2)
88.90
79.38
(3-1/8) (1-3/4)
0.79
228.60 120.65 206.38
92.08
2.27
(5)
(9)
(4-3/4) (8-1/8) (3-5/8)
138.11
(5-7/
16)
57.15
(2-1/4) (3-1/2)
88.90
79.38
(3-1/8)
0.91
(2)
with Pneumatic
—
—
—
—
—
—
—
—
—
—
—
Timer
N
160.34
(6-5/
16)
57.15
(2-1/4) (3-1/2)
88.90
79.38
(3-1/8) (2-1/4)
1.02
with Solid-State
Timer
—
C
A
A
C
A
C
D
B
B
D
D
B
Drawing Number 1
Drawing Number 2
Drawing Number 3
178.60
(7-1/32)
Cat. No. 7±±
#8 Screws
(Captive)
12.5
(1/2)
1.0
(0.04)
6.2
(15/64)
50
(1-63/64)
5.2
(13/64)
35.0
(1.38)
27.0
(1.06)
7.5
(0.3)
1000
(39-3/8)
3.98
(0.16)
2.25
(0.09)
0.5
(.02)
DIN Rail Adapter
0.5
(.02)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
175
Relay and Timer Specifications
700-R Sealed Switch Relays
•
•
•
•
•
•
Sealed contacts
Extremely long mechanical and electrical life
Hazardous locations Class 1, Div 2 Groups A, B, C, D
Harsh environments
Suitable for applications with shock and vibration
High reliability circuit integrity
Electrically Held
No.
of
AC-Operated Relay Only
Open Type
Cat. No.
DC-Operated Relay Only
Open Type
Cat. No.
Contacts
Contact Arrangement
and Markings‡
Poles
N.O.
0
N.C.
0
0
1
2
0
1
2
3
4
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
8
0
Relay without Contact
700-R000⊗
700-R200⊗
700-R110⊗
700-R020⊗
700-R400⊗
700-R310⊗
700-R220⊗
700-R130⊗
700-R040⊗
700-R600 ⊗
700-R510 ⊗
700-R420 ⊗
700-R330 ⊗
700-R240 ⊗
700-R150 ⊗
700-R060 ⊗
700-R800 ⊗
700-R710 ⊗
700-R620 ⊗
700-R530 ⊗
700-R440 ⊗
700-R350 ⊗
700-R260 ⊗
700-R170 ⊗
700-R080 ⊗
700DC-R000⊗
700DC-R200⊗
700DC-R110⊗
700DC-R020⊗
700DC-R400⊗
700DC-R310⊗
700DC-R220⊗
700DC-R130⊗
700DC-R040⊗
700DC-R600 ⊗
700DC-R510 ⊗
700DC-R420 ⊗
700DC-R330 ⊗
700DC-R240 ⊗
700DC-R150 ⊗
700DC-R060 ⊗
700DC-R800 ⊗
700DC-R710 ⊗
700DC-R620 ⊗
700DC-R530 ⊗
700DC-R440 ⊗
700DC-R350 ⊗
700DC-R260 ⊗
700DC-R170⊗
700DC-R080 ⊗
2
2
4
1
0
4
3
2
1
0
6
5
4
6
3
2
1
0
8
7
6
5
8
4
3
2
1
0
‡ Arrangement displays all N.O. contacts.
♣ Location of contacts in 6-pole relays.
Δ Polarity must be observed for DC voltage (700 DC) relays.
♦Location of contacts in 2-pole relays.
⊗ Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-R000⊗ becomes
Cat. No. 700-R000A24.
Coil Volts
Type of Relay
[V]
24
48
110
115-125
120
220
230-250
240
—
—
—
Z48
A1
—
—
Z1
—
A1
A2
—
—
Z2
—
A2
AC
DC
25, 50, 60 Hz
—
A24
Z24
—
—
—
—
—
—
176
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories - 700-R Relays
Pkg.
Qty.
Photo
Description
Cat. No.
Relay Rail
4 Relays per Strip
8 Relays per Strip
12 Relays per Strip
5
5
5
700-MP4
700-MP8
700-MP12
Simplifies panel layout. These indexed strips are
easily cut to the required length and bolted,
riveted, or spot-welded in place. Relays are
installed adjacent to one another on the
mounting strip with the captive mounting
screws provided. Rows of relays on Relay Rail
form their own wiring trough.
16 Relays per Strip
5
700-MP16
Can be used with the following relays: 700P,
700DC-P, 700S-P, 700N, 700-R, 700-RTC
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
DIN Rail Adapter
Can be used with the following relays:
700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC
1
700-DRA
Front Deck with one N.O. Contact
Cartridge (700-R Relay)
1
1
1
700-RA10
700-RA01
700-RB10
Front Deck with one N.C. Contact
Cartridge (700-R Relay)
Front Deck
A front deck can be attached to 700 2-, 3-, or 4-
pole AC and DC Type R relays.
Front Deck with one N.O. Contact
Cartridge (700-RM Relay)
Front Deck with one N.C. Contact
Cartridge (700-RM Relay)
1
700-RB01
Contact Cartridges
N.O. Contact Cartridge - Green
1
1
700-CR5
700-CR6
These cartridges are used to increase the number (700-R Relay)
of poles of a relay. A dummy cartridge is also
N.C. Contact Cartridge - Yellow
(700-R Relay)
available to fill empty space not occupied by a
contact cartridge.
“DUMMY”Cartridge - Black
(700-R Relay)
1
700-CR9
Cat. No.
700-CR5
Cat. No.
700-CR6
Cat. No.
700-CR9
12V DC (700-R Relay)
24V DC (700-R Relay)
48V DC (700-R Relay)
115…125V DC (700-R Relay)
1
1
1
1
Surge Suppressor
199-FSMA9
199-FSMA10
199-FSMA11
When the circuit to a DC operating coil is opened,
the inductive energy stored in the coil can
generate very high transient voltages. With the
addition of the appropriate surge suppressor, the
stored energy is absorbed and dissipated
limiting the voltage spikes. A surge suppressor is
not required with AC 700-R relays because the AC
operating coil transients are suppressed by a full
wave rectifier connected to the coil.
230…250V DC (700-R Relay)
1
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
177
Relay and Timer Specifications
Specifications - 700-R
Application Data – Because of the inherent characteristics of this device, the normally open contacts may close before the normally closed contacts
open on energization and the normally closed contacts may close before the normally open contacts open on de-energization.
Ratings
AC Voltage
DC Voltage
NEMA Rating
Designation
Voltage
Make
Break
Continuous NEMA Rating
Volts DC
Make/Break Continuous
Carrying
Designation
Carrying
Current [A]
Current [A]
120V
240V
480V
600V
30
15
3
B300
C600
Up to 300V AC
5
46…300
5…46
138 VA
3 A
5
5
1.5
NEMA P300
3.75
3.0
0.375
0.30
Above 300V AC
2.5
Maximum Allowable Off-State Leakage Current
Voltage
Maximum Off-State Leakage
Current [mA]
Type R
24V DC
24V AC
120V AC
23
23
5
Relay Data
Type
Contact Arrangement
700-R
Up to 8 poles, available in any combination of N.O. or N.C. contacts
W (tungsten in a controlled gas atmosphere)
Contact Material
24…250V AC
24…250V DC
Coil Voltage Range
Sealed
5.5 VA, 50/60 Hz
5.5 W DC
Voltage Range: –15… +10%
Coil Power
5.5 VA, 50/60 Hz
5.5 W DC
Inrush
30 ms
30 ms
Pickup Time
Dropout Time
–40…+60 °C (–40…+140 °F)
Panel mount
Operating Temperature
Mounting
Haz. Loc. Ratings
Standards Compliance
Certifications
Class I, Division 2, Groups A, B, C, and D
ISA 12.12, CSA C22.2, No. 213, EN/IEC 60947-1, -5-1
cULus Listed (File No. E10314, Guide NOIV/NOIV7), CE Marked
178
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-R Operating Coils
Coil Volts
700-R
2-…8-Pole AC
700-R
2-…8-Pole DC
60 Hz
77AB27
77AB134
77AB86
—
50 Hz
77AB27
77AB134
77AB86
—
24
48
77D152
77D166
—
110
115…125
120
77D155
—
77AB86
—
77AB86
—
208
—
220
77AB83
77AB83
—
77AB83
77AB83
—
—
240
—
230…250
77D156
Dimensions - 700-R
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
700-R Relays
Type of Relay
No. of
Poles
Open Type
Approx
. Ship
Wt. [kg
(lb)]
Type 1
General Purpose Enclosure
Approx
. Ship
Wt. [kg
(lb)]
Without Enclosures
Drawing
Number
A
B
High
C
D
A
Wide
B
C
D
E
Wide
Deep
High
Deep
55.56
(2-3/
16)
185.74 103.19
88.90
92.25
79.38
0.91
(2)
104.78
(4-1/8)
146.05
85.73
1.81
(4)
2…4
5…8
1
2
(7-5/
16)
(4-1/
16)
(3-1/2) (3-3/8) (3-1/8)
(5-3/4) (3-3/8)
700 and
700DC
R
55.56
(2-3/
16)
112.71
(4-7/
16)
88.90
111.13
79.38
1.02
228.60 120.65 206.38
92.08
2.49
(5)
(3-1/2) (4-3/8) (3-1/8) (2-1/4)
(9)
(4-3/4) (8-1/8) (3-5/8)
A
C
C
A
B
D
B
D
700-R400…
700-R800…
A
E
C
3.98
(0.16)
B
D
2.25
(0.09)
0.5
(.02)
0.5
(.02)
Type 1 Enclosure
DIN Rail Adapter
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
179
Relay and Timer Specifications
Cat. No. 7±±
Secure the mounting strip with 2
screws at each end relay position. Use
a minimum of one screw at the 3rd,
5th, 7th, etc., relay positions. Alternate
between upper and lower horizontal
slots.
#8 Screws
(Captive)
Relay Rail
12.5
6.2
(15/64)
1.0
(0.04)
50
(1-63/64)
(1/2)
5.2
(13/64)
35.0
27.0
(1.38)
(1.06)
7.5
1000
(0.3)
(39-3/8)
Cat. No. 199-DR1 DIN Mounting Rail Series B
180
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-RTC — Solid-State Timing Relay
•
•
•
•
•
•
•
•
•
•
•
•
•
Timing functions
8 ON-delay
8 OFF-delay
Timing ranges
Seconds: 0.05…2, 0.2…8, 0.4…30, 2…120
Minutes: 0.015…1, 0.06…4, 0.25…16 and 1…64
AC, 50/60 Hz or DC
600V AC maximum
300V DC maximum
Relays with fixed time delay
Sealed contacts
Harsh environments
Hazardous locations Class I, Div. 2, Groups A, B, C and D
700-RTC Relay with Adjustable Time Delay – Relays with Provision for Instantaneous Contacts
Relays listed below have slots for two timed contacts and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.
Number of Contact Cartridges
Open Type Without Enclosure
Cat. No.
Instantaneous
Timed
N.O.
0
Total
N.O.
N.C.
N.C.
0
1
0
0
0
700-RTC00000⊗
0
0
0
1
0
0
1
0
0
1
2
0
1
1
2
0
0
1
1
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
0
2
1
1
0
2
1
1
0
2
1
1
1
0
0
0
2
1
2
1
1
0
1
1
0
0
0
0
0
1
0
0
0
1
1
1
2
0
0
0
0
1
1
0
1
1
2
1
2
700-RTC00100⊗
700-RTC00010⊗
700-RTC00200⊗
700-RTC10100⊗
700-RTC01100⊗
700-RTC00110⊗
700-RTC10010⊗
700-RTC01010⊗
700-RTC00020⊗
700-RTC10200⊗
700-RTC20100⊗
700-RTC01200⊗
700-RTC11100⊗
700-RTC10110⊗
700-RTC20010⊗
700-RTC02100⊗
700-RTC01110⊗
700-RTC11010⊗
700-RTC10020⊗
700-RTC02010⊗
700-RTC01020⊗
2
3
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
181
Relay and Timer Specifications
Number of Contact Cartridges
Open Type Without Enclosure
Cat. No.
Instantaneous
Timed
N.O.
Total
N.O.
N.C.
N.C.
2
1
2
0
1
2
1
0
0
0
1
0
2
1
0
1
2
2
2
2
1
2
1
0
0
1
0
0
0
1
0
1
2
2
1
2
700-RTC20200⊗
700-RTC11200⊗
700-RTC20110⊗
700-RTC02200⊗
700-RTC11110⊗
700-RTC20020⊗
700-RTC11020⊗
700-RTC02110⊗
700-RTC02020⊗
4
⊗ Coil Voltage Code
The Cat. No. as listed is not complete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-RTC00100⊗
becomes Cat. No. 700-RTC00100U24. For other voltages consult your local Rockwell Automation sales office or Allen-Bradley distributor.
[V]
24V DC, 24V AC
120V DC, 110/120V AC
50/60 Hz
U24
U1
700-RTC Relays with Fixed Time Delay— Relays with Provision for Instantaneous Contacts
Relays listed below have slots for two timed and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.
Number of Contact Cartridges
Open Type Without Enclosure
Cat. No.
Timed
Instantaneous
N.O.
Total
N.O.
N.C.
N.C.
0
1
0
1
0
2
1
1
1
0
0
0
2
1
2
1
1
0
1
1
0
0
0
0
0
0
1
0
0
0
1
1
1
2
0
0
0
0
1
1
0
1
1
2
1
2
0
0
0
0
1
0
0
1
0
0
1
2
0
1
1
2
0
0
1
1
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
0
2
1
1
0
2
1
700-RTC00#0⊗
700-RTC10#0⊗
700-RTC20#0⊗
700-RTC40#0⊗
700-RTC11#0⊗
700-RTC12#0⊗
700-RTC30#0⊗
700-RTC21#0⊗
700-RTC22#0⊗
700-RTC50#0⊗
700-RTC41#0⊗
700-RTC14#0⊗
700-RTC42#0⊗
700-RTC13#0⊗
700-RTC31#0⊗
700-RTC24#0⊗
700-RTC15#0⊗
700-RTC32#0⊗
700-RTC23#0⊗
700-RTC51#0⊗
700-RTC25#0⊗
700-RTC52#0⊗
2
3
182
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Number of Contact Cartridges
Open Type Without Enclosure
Cat. No.
Timed
Instantaneous
N.O.
Total
N.O.
N.C.
N.C.
2
2
1
2
0
0
1
0
1
2
1
2
2
2
1
2
0
1
2
0
1
0
0
1
0
2
1
0
2
1
2
700-RTC44#0⊗
700-RTC43#0⊗
700-RTC34#0⊗
700-RTC45#0⊗
700-RTC33#0⊗
700-RTC54#0⊗
700-RTC35#0⊗
700-RTC53#0⊗
700-RTC55#0⊗
4
1
0
1
0
0
# Operating Mode
Replace the # in the cat. no. with the appropriate letter and numbers to indicate the operating mode and the fixed time delay value. Refer to
operating mode table below.
Digit
Operating Mode
On-Delay – s
Fixed Time Delay
S
Z
Y
I
Seconds –Two digits indicating the fixed time delay in seconds.
Three digits indicating the fixed time delay (first digit indicates seconds, next
two digits indicate 1/100 seconds).
Off-Delay – s
On-Delay – Min.
Off-Delay – Min.
Minutes –Two digits indicating the fixed time delay in minutes.
Three digits indicating the fixed time delay (first digit indicates minutes, next
two digits indicate 1/100 minutes).
EXAMPLE Cat. No. 700-RTC00Y200U1 is for a relay without contact cartridges. “Y20”indicates an On-Delay timer with a 20 minute fixed
time delay. This is a“standard relay.”Order the contact cartridges separately.
Cat. No. 700-RTC42S020U1 is for a relay with 2 N.O. cartridges in the timed position and 1 N.C. cartridge in the instantaneous
position. “S02”indicates an On-Delay timer with a 2 second fixed time delay.
⊗ Coil Voltage Code
The cat. no. as listed is not complete. To complete the cat. no., add a coil code selected from the table below.
[V]
24V DC, 24V AC
120V DC, 110/120V AC
50/60 Hz
U24
U1
Accessories - 700-RTC Relays
Description
Cartridge Type
Color
Cat. No.
Photo
N.O.
Grey
700-CRT5
Contact Cartridges – These cartridges are used to add contacts
to timing relays having unused slots. The N.O., N.C., and Dummy
cartridges are interchangeable and can be used in timed or
instantaneous contact slots. Dummy cartridges should be placed in
unused cartridge slots to guard against entrance of foreign
material.
N.C.
Orange
700-CRT6
700-CR9
Cat. No.
700-CRT5
Cat. No.
700-CRT6
Cat. No.
700-CR9
Dummy Cartridge Black
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
183
Relay and Timer Specifications
Description
Cartridge Type
Color
Cat. No.
Photo
Type 1 Enclosure — Use for all 700-P relays except 10- and 12-pole DC relays or 6-pole DC 700-PH
relays.
700-N31
Relays per Strip
Pkg. Quantity
Relay Rail
700-MP4
Simplifies panel layout. These indexed strips are easily cut to the
required length and bolted, riveted, or spot-welded in place.
Relays are installed adjacent to one another on the mounting strip
with the captive mounting screws provided. Rows of relays on
Relay Rail form their own wiring trough.
4
5
5
5
5
8
700-MP8
700-MP12
700-MP16
12
16
Can be used with the following relays: 700P, 700DC-P, 700S-P,
700N, 700-R, 700-RTC
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
DIN Rail Adapter
Can be used with the following relays:
700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC
1
700-DRA
Specifications - 700-RTC Relays
Voltage and Power Requirements
AC Voltage
+10ꢀ –15ꢀ 50/60 Hz
Total Power Required
Initiate Terminal Power
Maximum Allowable
Leakage Current
Coil Code
24V AC
8 VA
9 VA
4 VA
4 VA
10 mA
U24
U1
110/120V AC
2.4 mA
DC Voltage
+10ꢀ –20ꢀ
Total Power Required
Initiate Terminal Power
Maximum Allowable
Leakage Current
Coil Code
24V DC
10 W
11 W
5 W
5 W
10 mA
U24
U1
120V DC
2.4 mA
Type
700-RTC
NEMA B600 600V AC, 5 A
NEMA P300 300V DC, 5 A
Contact Rating
1…4 poles. Max. of 2 timed and 2 instantaneous.
Available in any combination of N.O. and N.C. contacts
Contact Arrangement
Contact Material
Operating Mode
W (tungsten in a controlled gas atmosphere)
Convertible to ON-Delay or OFF-Delay
184
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Type
700-RTC
Timing Range
Reset Time
0.015…64 minutes; 0.05...120 seconds
25 ms
Repeat Accuracy
Mounting
1% (or 50 ms) at constant voltage and temperature
Panel or strip mount
Surge Suppression
Haz. Loc. Ratings
Not required. Timers have internal suppression
Class I, Division 2, Groups A, B, C, and D
24V AC/DC
10 mA
2.4 mA
Maximum Allowable Leakage Current
110/120V AC,
120V DC
Ambient Temperature (1)
Operating:
–20…+60 °C
(–4…+140 °F)
–20…+60 °C
(–4…+140 °F)
Storage:
Standards Compliance
Certifications
ISA 12.12, CSA C22.2, No. 213
cULus Listed (File No. E10314, Guide NOIV/NOIV7)
(1) Continuous duty units placed close to each other (3 in a row) have a temperature range of –20…+45 °C (–4…+113 °F) or should have air circulated around the units.
Approximate space of 3/4 in (mm) on all sides is needed.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
185
Relay and Timer Specifications
Typical Wiring Diagram - 700-RTC Relays
L1
L2
External
Initiating Contact
(N.O. or N.C.)
Timed Contacts
Any Combination
of N.O. and N.C.
P TIMED
INST
Instantaneous
Contacts Any
Combination of
N.O. and N.C.
L1 +
L2
Dimensions - 700-RTC Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
5.2 (2-13/64) Dia. Mounting Holes
Approximate Shipping Weight 0.92 kg (2.1 lb.)
NEMA Type 1 Enclosure for RTC Relays
Approximate Shipping Weight 1.26 kg (2.8 lb.)
186
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
IEC Control Relays
Product Overview
Bulletin No.
Type
700-CF and 700S-CF
700-K
Control Relay
Miniature Control Relay
•
•
•
•
Mechanically linked contacts
Timer and latch operations
Switch up to 690V AC and DC
700S-CF for safety circuits
•
•
•
•
Smallest size
Long life
Features
Low power consumption
Switch up to 690V AC and DC
Contact Form
Contact Type
Contact Material
Electrical
4…12 poles, double break
Cross stamp or bifurcated
Silver, gold
4...8 Poles Double Break
Bifurcated
Silver
20 A (relay)
Max. Current AC Resistive
Min. load
10 A
10 A (adder deck)
17V, 10 mA (Silver)
5V, 3 mA (Gold)
15V, 2 mA (700-K)
12…600V AC
9…250V DC
12…600V AC
9…250V DC
Coil Voltage
85…110% AC coils,
80…110% DC coils
85…110% AC Coils,
80…110% DC Coils
Coil Voltage Pickup
Dielectric Withstand
Reference
2.5 kV
2640V
Electric Service Life (cycles)
Certifications
Sockets
1.2 million at 10 A
CE, cULus, CCC
DIN Rail or panel mount
188
800K at 10 A 120V AC
CE, cULus, CCC
DIN Rail or panel mount
213
Page
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
187
Relay and Timer Specifications
700-CF Control Relay
•
•
•
•
•
•
IEC industrial relays
Mechanically linked contact performance per IEC 60947-5-1
Gold plated, bifurcated version for low level switching applications
Master control relay version rated 15 A (AC-15)
Solid-state and pneumatic timing modules
4-…10 Poles
4-Pole AC Coil Voltage (Ratings for 700-CF Only)
AC-12
Ith [A]
40 °C
AC-15
Contacts
Gold Plated
Bifurcated
Contacts(2)
Standard
Master
Contacts(1)
Contacts(2)
Connection
Diagrams
Ie [A]
60 °C
24/48V 120V 240V 400V 500V 600V 690V
N.O. N.C.
Cat. No.
Cat. No.
Cat. No.
2
2
700-CF220⊗ 700-CFB220⊗ 700-CFM220⊗
700-CF310⊗ 700-CFB310⊗ 700-CFM310⊗
700-CF400⊗ 700-CFB400⊗ 700-CFM400⊗
3
4
1
0
20
20
10
10
10
6
2.5
1
1
0
4
700-CF040⊗ 700-CFB040⊗
—
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D.
(2) All Cat. Nos. are factory-stocked.
⊗ AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220⊗ becomes
Cat. No. 700-CF220D for 120V, 60 Hz.
100...
110
200...
220
208...
240
220...
230
230...
240
[V]
12
24
32
36
42
48
100
110
120
127
200
208
230
240
50 Hz
60 Hz
R
Q
K
J
V
W
V
X
Y
X
KP
—
KP
D
P
S
KG
L
—
H
—
L
F
—
—
VA
T
—
—
—
—
D
—
—
KG
—
—
A
50/60
Hz
—
KJ
—
—
—
KY
KP
—
KD
—
—
KG
KL
—
—
KL
KF
—
KA
380...
400
400...
415
[V]
277
347
380
400
440
480
500
550
600
50 Hz
—
T
—
I
—
E
N
—
—
KN
G
B
—
B
M
C
—
C
60 Hz
—
—
—
—
N
—
—
—
—
50/60 Hz
—
—
—
KB
—
—
188
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
4-Pole DC Coil Voltage (Ratings for 700-CF Only)
AC-12
AC-15
Contacts
Gold Plated
Master
Standard
Bifurcated
Contacts(2)
Contacts(2)
Contacts(1)
Connection
Diagrams
Ith[A]
Ie [A]
40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V
N.O. N.C. Cat. No.
Cat. No.
Cat. No.
2
2
700-CF220
⊗
700-CFB220⊗ 700-CFM220⊗
3
4
1
0
20
20
10
10
10
6
2.5
1
1
700-CF310⊗ 700-CFB310⊗ 700-CFM310⊗
700-CF400⊗ 700-CFB400⊗ 700-CFM400⊗
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D.
(2) All Cat. Nos. are factory-stocked.
⊗DC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220⊗ becomes
Cat. No. 700-CF220EJ for 24V DC, electronic with diode.
48...
72
110...
125
220...
250
[V]
9
12
24
36
48
60
64
72
80
110
115 125 220
230 250
Electronic with
diode
—
EQ
EJ
EW
—
EY
—
—
—
—
—
ED
—
—
—
—
—
—
EA
—
—
—
—
Electronic with
diode/ Quick
Pick-up
—
—
QJ
—
—
—
—
—
—
—
—
—
—
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
189
Relay and Timer Specifications
6- and 8-pole Relays
Control Relays with Overlapping Side-Mounted Contacts
AC-12
AC-15
Overlapping
Side-
Mounted
Contacts
Contacts
Ith [A]
Ie [A]
Left Relay
Aux. Arrangement Aux.
Right
Cat. No.
40 60 24/
°C °C 48V
120 240 400 500 600 690
N.O. N.C. N.O. N.C.
V
V
V
V
V
V
4
3
2
4
3
2
0
1
2
0
1
2
1
1
1
2
2
2
1
1
1
2
2
2
700-CFZ1510⊗
700-CFZ1420⊗
700-CFZ1330⊗
700-CFZ2620⊗
700-CFZ2530⊗
700-CFZ2440⊗
Main
Relay
20 20 10
10
10
6
2.5
1
1
Side
Contacts
10 10
6
6
5
3
1.6
1
1
190
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Control Relays with Standard Side-mounted Contacts
AC-12
AC-15
Standard
Side-
Contacts
Mounted
Ith [A]
Ie [A]
Left
Aux.
Relay
Arrangement
Right
Aux.
Cat. No. (1)
Contacts
40 60 24/
°C °C 48V
120V 240V 400V 500V 600V 690V
N.O. N.C. N.O. N.C.
700-
4
3
2
4
3
2
0
1
2
0
1
2
1
1
1
2
2
2
1
1
1
2
2
2
CFZ0510⊗
Main
Relay
700-
CFZ0420⊗
20 20 10
10
10
6
2.5
1
1
700-
CFZ0330⊗
700-
CFZ0620⊗
Side
Contacts
700-
CFZ0530⊗
10 10
6
6
5
3
1.6
1
1
700-
CFZ0440⊗
(1) All Cat. Nos. are factory stocked.
⊗ AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ051
⊗
becomes Cat. No. 700-CFZ0510F.
100...
110
200...
220
208...
240
220...
230
230...
240
[V]
12
24
32
36
42
48
100
110
120
127
200
208
230
240
50 Hz
60 Hz
R
Q
K
J
V
W
V
X
Y
X
KP
—
KP
D
P
S
KG
L
—
H
—
L
F
—
—
VA
T
—
—
—
—
D
—
—
KG
—
—
A
50/60
Hz
—
KJ
—
—
—
KY
KP
—
KD
—
—
KG
KL
—
—
KL
KF
—
KA
380...
400
400...
415
[V]
277
347
380
400
440
480
500
550
600
50 Hz
—
T
—
I
—
E
N
—
—
KN
G
B
—
B
M
C
—
C
60 Hz
—
—
—
—
N
—
—
—
—
50/60 Hz
—
—
—
KB
—
—
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
191
Relay and Timer Specifications
Assignment of Contacts
Device Combinations in Accordance with IEC 60947-1 / -4-1
Auxiliary Contact Blocks
Control Relays 700-CF (AC and DC Control)
Circuit Diagram
Control
700-CF⊗220
700-CF⊗310
700-CF⊗400
(1)
FrontMounting
51 61
100-FA02
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
22E + 02E = 24Y
22E + 11E = 33Y
22E + 20E = 42Y
22E + 22E = 44Y
22E + 31E = 53Y
22E + 40E = 62Y
22E + L22E = L44Y
31E + 02E = 33Y
31E + 11E = 42Y
31E + 20E = 51Y
31E + 22E = 53Y
31E + 31E = 62Y
31E + 40E = 71Y
31E + L22E = L53Y
40E + 02E = 42Y
40E + 11E = 51Y
40E + 20E = 60Y
40E + 22E = 62Y
40E + 31E = 71Y
40E + 40E = 80Y
40E + L22E = L62Y
52 62
53 61
100-FA11
100-FA20
100-FA22
100-FA31
100-FA40
100-FAL22
54 62
53 63
54 64
53 61 71 83
54 62 72 84
53
73 83
61
54 62 74 84
63 73 83
53
54 64 74 84
53 61 75 87
54 62 76 88
(1) Control relay and auxiliary contact block AC/DC max. 4 N. C.
192
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Auxiliary Contacts
Standard
Contacts
Bifurcated
Contacts
(1)
For Use
With
Photo
Description
N.O.
N.C.
Connection Diagrams
Cat. No.
Cat. No.
0
1
2
1L
0
1
2
3
4
2
1
0
1L
4
3
2
1
0
100-FA02
100-FA11
100-FA20
100-FAL11
100-FA04
100-FA13
100-FA22
100-FA31
100-FA40
100-FAB02
100-FAB11
100-FAB20
—
Auxiliary Contact Blocks for Front
Mounting§
2- and 4-pole
Quick and easy mounting without tools
Electronic-compatible contacts down to
17V, 5 mA
100-FAB04
100-FAB13
100-FAB22
100-FAB31
100-FAB40
Mechanically linked performance
between N.O. and N.C. poles and to the
main relay poles (except for L types)
Models with equal function with several
terminal numbering choices
1L = Late break N.C./early make N.O.
Bifurcated version for switching down to
5V, 3 mA
700-CF
1+1L
1+1L
100-FAL22
—
(1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFA02.
Description
N.O.
N.C.
Connection Diagrams
For Use With Cat. No.
Photo
0
1
0
1
2
1
0
2
1
0
100-SA01
100-SA10
100-SA02
100-SA11
100-SA20
Auxiliary Contact Blocks for Side Mounting without
Sequence Terminal Designations§
1- and 2-pole
Two-way numbering for right or left mounting on the contactor
Quick and easy mounting without tools
700-CF
Electronic-compatible contacts down to 17V, 10 mA
Mirror contact performance to the main relay poles
1L = Late break N.C./early make N.O.
1L
1L
100-SAL11
IMPORTANT For maximum number of contacts, see the following tables.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
193
Relay and Timer Specifications
(1)
700-CF (AC electronic coils), vertical mounting, 60 °C
Max. N.O.
Front + Side
Aux.
Max. N.C.
Front + Side
Aux.
Max. N.O. + N.C.
Front +
Side Aux.
Cat. No.
700…
Max. N.O.
Side Aux.
Max. N.C.
Side Aux.
Max. N.O.
Front Aux.
Max. N.C.
Front Aux.
CF400
CF310
CF220
CF040
2
2
4
2
4
4
4
4
4
4
6
6
8
6
7
5
5
2
8
8
8
6
(2)
4
4(3)
2
(2)
4
2
0
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
(2) With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum
(3) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum
(1)
700-CF (DC conventional coils), vertical mounting, 60 °C
Max. N.O.
Front + Side
Aux.
Max. N.C.
Front + Side
Aux.
Max. N.O. + N.C.
Front +
Side Aux.
Cat. No.
700…
Max. N.O.
Side Aux.
Max. N.C.
Side Aux.
Max. N.O.
Front Aux.
Max. N.C.
Front Aux.
CF400
CF310
CF220
2
2
2
2
2
2
4
4
4
4 (2)
4 (2)
2
6
6
6
5
5
4
8
8
8
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
(2) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum
194
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Control Modules
Connection
Diagrams
Reset
Time
Repeat
Accuracy
Photo
Description
Delay
For Use With
Cat. No.
Pneumatic Timing
0.3…30 s
100-FPTA30
Modules(1) ON-Delay
Pneumatic timing element
contacts switch after the delay
time. The contacts on the main
control relay continue to
operate without delay.
25…90
ms for AC
Coils
1.8…180 s
0.3…30 s
1.8…180 s
100-FPTA180
100-FPTB30
100-FPTB180
(1)
+/-10%
700-CF all
Pneumatic Timing Modules
OFF-Delay
Pneumatic timing element
contacts switch after the delay
time. The contacts on the main
control relay continue to
operate without delay.
47…85
ms
for DC coils
0.1…3 s
1…30 s
10…180 s
0.1…3 s
1…30 s
100-ETA3
700-CF
110…240V AC
110…250V DC
100-ETA30
Electronic Timing Modules
— On-Delay
conventional coils
100-ETA180
100-ETAZJ3
100-ETAZJ30
Delay of the control relay coil
assembly.
100 ms
+/-1%
The control relay is energized
at the end of the delay time.
700-CF
24…48V DC
coils
10…180 s
100-ETAZJ180
0.3…3 s
1…30 s
10…180 s
0.3…3 s
1…30 s
100-ETB3
700-CF
110…240V AC
coils
100-ETB30
100-ETB180
100-ETBKJ3
100-ETBKJ30
Electronic Timing Modules
— Off-Delay
Delay of the control relay coil
assembly.
100 ms
+/-1%
After interruption of the
control signal, the control relay
is deenergized at the end of
the delay time.
700-CF
24V AC
coils
10…180 s
100-ETBKJ180
(1) On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays.
Connection
Diagrams
Photo
Description
For Use With
Cat. No.
Mechanical Latch
Following relay latching, the relay coil is immediately de-energized (off) by the
N.C. auxiliary contact (65-66).
700-CF with AC
coils
100-FL11⊗
Electrical or manual release
1 N.O. + 1 N.C. auxiliary contacts
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
195
Relay and Timer Specifications
Connection
Diagrams
Photo
Description
For Use With
Cat. No. (1)
100-FSC48
100-FSC280
100-FSC480
100-FSV55
100-FSV136
24…48V
50/60 Hz
RC Module
AC Operating
Mechanism
110…280V
50/60 Hz
700-CF with AC coils
380…480V
50/60 Hz
12…55V AC/
12…77V DC
Surge Suppressors
For limitation of coil switching
transients.
56…136V AC/
78…180V DC
Varistor Module
AC/DC Operating
Mechanism
700-CF all
Plug-in, coil mounted
137…277V AC/
181…350V DC
100-FSV277
100-FSV575
278…575V AC
Diode Module
DC Operating
Mechanism
Dropout Time
70…95 ms
700-CF with Conventional DC
coils
12…250V DC
100-FSD250
(1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFSC48.
Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11⊗ becomes
Cat. No. 100-FL11J.
[V] (1)
50 Hz
60 Hz
24
K
48
Y
100
KP
110
D
120
—
D
230...240 240
277
—
T
380...400 400...415 440
480
—
B
VA
T
N
G
B
J
—
—
—
—
A
—
—
N
(1) For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Connection
Diagrams
For Use With
(Relays)
Photo
Description (Relays)
Cat. No.
Input:
24V DC
Output:
110…240V AC
100-JE
DC Interface (electronic)
Interface between the DC control signal (PLC) and the AC
Input:
operating mechanism of the control relay.
12V DC
700-CF with
110…240V AC
coils
Control (input) voltage
100-JE12
100-JE48
Output:
110…240V AC
12V DC
24V DC
48V DC
Input:
Requires no additional surge suppression on the relay coils
48V DC
Output:
110…240V AC
196
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications 100-J... DC Interfaces
Cat. No. 100-JE
Cat. No. 100-JE12
Cat. No. 100-JE48
Electrical
Input Voltage
24V DC
12V DC
48V DC
Input Voltage Range
Output Voltage
Power Consumption
Minimum Actuation
Mechanical
18…30V DC
110…240V AC
0.1…0.4 W
6…12V DC
35…48V DC
110…240V AC
0.2…0.5 W
110…240V AC
0.02…0.12 W
5V DC, 2 mA DC
5V DC, 2 mA DC
5V DC, 2 mA DC
Finger Protection
IP20
IP20
IP20
0…10 ms + pickup time
of the contactor
0…10 ms + pickup time
of the contactor
0…10 ms + pickup time
of the contactor
Pickup Time
0…10 ms + dropout time
of the contactor
0…10 ms + dropout time
of the contactor
0…10 ms + dropout time
of the contactor
Dropout Time
Max. Cycles Per Second
Isolation/Breakdown Voltage
Rated Impulse Withstand Voltage
Environmental
2 (1)
In: 50V, Out: 250V
4 kV
2 (1)
In: 50V, Out: 250V
4 kV
2 (1)
In: 50V, Out: 250V
4 kV
Ambient Temperature Range
Storage Temperature Range
Operating Life
-25…+60 °C
-50…+80 °C
-25…+60 °C
-50…+80 °C
-25…+60 °C
-50…+80 °C
100 + million ops
100 + million ops
100 + million ops
Construction
2
2
2
1 Wire
2 Wire
1 Wire
2 Wire
0.5…2.5 mm
0.5…2.5 mm
0.5…2.5 mm
Flexible wire
2
2
2
0.75…2.5 mm
0.75…2.5 mm
0.75…2.5 mm
2
2
2
Wire Size Range
Solid wire
1.0…2.5 mm
1.0…2.5 mm
1.0…2.5 mm
2
2
2
1.0…2.5 mm
1.0…2.5 mm
1.0…2.5 mm
Solid and Stranded
Tightening Torque
18…14 AWG
1…1.5 N•m / 7…15 lb•in
LED
18…14 AWG
1…1.5 N•m / 7…15 lb•in
LED
18…14 AWG
1…1.5 N•m / 7…15 lb•in
LED
Type of Light
(1) To consider the maximum operations/hour of the relays.
Assembly Components
Photo
Description
For Use With
Pkg Qty. (1)
Cat. No.
Protective Covers
Provides protection against unintended manual operation
700-CF all
1
100-SCCA
Protective Covers
100-FA, -FB, -FC, -FP, -FL; 10
100-SCFA
•
•
Provides protection against unintended manual operation
For contactors and front-mounted auxiliary contacts, pneumatic timers,
and latches
(1) All Cat. Nos. are factory stocked.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
197
Relay and Timer Specifications
Accessories
Uniform labeling materials for contactors, motor startup equipment, relays, and circuit breakers.
Pkg.
Photo
Description
Cat. No.
Qty. (1)
10
100-FMS
Label Sheet
105 self-adhesive paper labels each, 6 x 17 mm
10
100-FMP
100-FMC
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
Transparent Cover To be used with marking tag sheets
100
100-FMA1 (2)
100-FMA2
100
Marking Tag Adapters To be used with marking tag: System V4/V5
System 1492 W
(1) Must be ordered in multiples of package quantities.
(2) Marker for 100-FMA1 must be purchased from a third party.
198
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Coils
Photo
AC Coil
Code
AC Voltages
60Hz
12V
Cat. No.
700-CF
DC Coil Code DC Voltages
Cat. No.
700-CF
50Hz
—
50/60Hz
—
Q
R
TA006
EQ
EJ
12V
24 V
TC708E
TC714E
TC714Q
TC724E
TC719E
12V
—
—
TA404
TA013
TA407
TA855
TA481
TA410
TA482
TA414
TA860
TA861
TA473
TA856
TA425
TA428
TA862
TA049
TA296
J
—
24V
—
QJ
24V
K
24V
—
—
E Y
EW
ED
EA
48…72V
36…48
KJ
V
—
—
24V
—
32V
36V
110…125 TC733E
220…250 TC747E
W
X
36V
—
—
42V
48V
—
Y
48V
—
—
KY
KP
D
—
—
48V
100V
—
100V
110V
—
100 - 110V
120V
—
KD
P
110V
—
120V
127V
200V
—
—
S
—
—
KG
H
200 - 220V
208V
208 - 240V
—
200V
—
L
200 - 220V
—
—
KL
A
200 - 230V TA864
220V
220 - 230V
—
240V
260V
—
—
—
TA474
TA441
TA851
TA440
TA480
TA858
TA065
TA067
TA071
TA863
TA457
TA475
TA859
TA479
TA476
F
KF
VA
T
230V
—
230 - 240V
240V
—
—
277V
—
—
KA
I
240V
—
—
347V
380V
440V
—
E
—
—
N
380 - 400V
—
—
KN
G
400V
—
400-415V
440V
—
—
B
480V
—
—
KB
M
C
440V
—
500V
550V
—
600V
—
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
199
Relay and Timer Specifications
Specifications - 700-CF..., 700S-CF Relays
Main Relay
Cat. Nos.
700-CF,
FrontMounted
Standard
Main Relay
Cat. No.
700-CFB,
700S- CFB
Master Relay FrontMounted Side-mounted
Cat. No.
Bifurcated
Auxiliary
Contacts
Auxiliary
Contacts
Auxiliary
700-CFM
700S- CF
Contacts
Contact Ratings — NEMA
A600, P600
17V, 10 mA
10 A
A600, Q600
17V, 5 mA
6 A
A600, Q600
8V, 5 mA
3 A
2 x A600, P600
A600, Q600
5V, 3 mA
3 A
A600, Q600
17V, 10 mA
6 A
Min. Contact Rating
—
15 A
15 A
15 A
15 A
7.5 A
5 A
24V
48V
10 A
6 A
3 A
3 A
6 A
120V
10 A
6 A
3 A
3 A
6 A
Contact Ratings — IEC AC-15
(solenoids, contactors) at rated
voltage
240V
10 A
5 A
3 A
3 A
5 A
400V
6 A
3 A
2 A
2 A
3 A
IEC 60947-5-1
480V/500V
2.5 A
1 A
1.6 A
1 A
1.2 A
0.7 A
0.7 A
1.2 A
0.7 A
0.7 A
1.6 A
1 A
600V
690V
2 A
1 A
1 A
2 A
1 A
I
20 A
th
230V
400V
690V
8 kW
14 kW
24 kW
20 A
40 °C
60 °C
10 A
6 A
10 A
6 A
20 A
20 A
10 A
6 A
10 A
6 A
AC-12 (Control of
resistive loads)
IEC 60947-5-1
I
th
230V
400V
690V
24V
8 kW
14 kW
24 kW
15 A
10 A
9 A
6 A
3.2 A
1 A
20 A
20 A
8 A
6 A
3.2 A
1 A
6 A
3.2 A
1 A
48V
10 A
DC-12 Switching DC Loads L/R <
1ms, Resistive Loads
110V
220V
440V
24V
6 A
3.5 A
0.7 A
0.2 A
5 A
IEC 60947-5-1
1 A
0.5 A
0.2 A
2.5 A
1.5 A
0.6 A
0.3 A
0.15 A
1.5 A
0.4 A
5 A
0.5 A
0.2 A
2.5 A
1.5 A
0.6 A
0.3 A
0.15 A
0.5 A
0.2 A
5 A
0.4 A
5 A
48V
3 A
3 A
3 A
2.5 A
0.68 A
0.32 A
0.15 A
DC-13 IEC 60947-5-1,
Solenoids and contactors
110V
220V
440V
1.2 A
0.6 A
0.3 A
1.2 A
0.6 A
0.15 A
1.2 A
0.6 A
0.3 A
State of N.C. Contacts if N.O. contact welds
Location of welded
N.O. contacts
Main
Open
Open
Front aux.
Open
Side aux.
Open (2)
Main
Mechanically Linked Contacts (1)
Front aux.
Open
—
(1) Side mounted auxiliary contacts provide “mirror contact”performance with main poles only.
(2) Defined in IEC 60947-5-1 annex L. Mechanically linked is a relationship between contacts of opposite types (i.e., N.O. and N.C.).
200
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
Aux./Pneumatic
Timer Contact
(Front mounted)
Cat. No.
700-CF
Mechanical Life
Electrical Life
[Mil]
[Mil]
[g]
15
1.5
390
5
AC-15
1.5
—
(240V, 3 A)
Weight
AC Coil
Terminal Cross-Sections
Terminal Type
Terminal Size per IEC60 947-1
2 x A4
1.5…6
2 x A4
0.5…2.5
0.75…2.5
18…14
2
[mm ]
Solid/Stranded
1 Conductor
2 Conductor
(1)
2
[mm ]
1.5…6
Max. Wire Size per UL/CSA
Tightening Torque
[AWG]
[lb·in]
[N·m]
16…10
13.3…17.7
1.5…2.0
8.9…13.3
1…1.5
Tightening Torque
(1) For 16 or more strands, end ferrule is required.
DC Switching Ratings for 700-CF Main Poles in Series (Resistive Load at 60 °C)
Attribute
24/48V
125V
1 pole
2 poles
3 poles
15/10 A
6 A
25 A
25 A
6 A
25 A
25 A
25 A
3 A
220V
1 A
440V
0.4 A
1 A
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
201
Relay and Timer Specifications
Control Circuit
Attribute
Cat. No. 700-CF
Operating Voltage
Pickup
Dropout
Pickup
[x U ]
0.85…1.1
0.3…0.6
0.8…1.1
0.1…0.6
0.7...1.25
0.3...0.4
s
AC 50/60 Hz
[x U ]
s
[x U ]
s
DC (conventional) (1)
DC (electronic EQ, EW)
DC (electronic EY)
Dropout
Pickup
[x U ]
s
[x U ]
s
Dropout
Pickup
[x U ]
s
[x U ]
0.8...1.25
0.3...0.4
0.7...1.12 (2)
s
Dropout
Pickup
[x U ]
s
[x U ]
s
DC (electronic ED)
Dropout
Pickup
[x U ]
s
0.3...0.4
[x U ]
0.8...1.1
s
DC (electronic EA)
Coil Consumption
AC 50/60 Hz
Dropout
[x U ]
0.3...0.4
s
Inrush
Sealed
Inrush
Sealed
[VA]
[VA/W]
[W]
75
9.5/2.7
7.7
DC (conventional)
DC (electronic EQ, EJ)
DC (electronic EY)
DC (electronic ED)
[W]
6.3
Inrush (avg./ peak)
Sealed
[W]
10/17
1.7
[W]
Inrush (avg./ peak)
Sealed
[W]
10/17
1.9
[W]
Inrush (avg./ peak)
Sealed
[W]
12/19
2.1
[W]
Inrush (avg./ peak)
Sealed
[W]
14/22
3.0
DC (electronic EA)
Operating Times
AC 50/60 Hz
[W]
Pickup Time
Dropout Time
Pickup Time
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
15…30
10…60
40…70
7…15
14...20
70...125
25…50
27...45
25...50
23...33
20...50
15…22
DC (conventional)
Dropout Time
Opening Delay
Opening Delay
Closing Delay
Opening Delay
Closing Delay
Opening Delay
Closing Delay
Opening Delay
With integrated diode
With external diode
DC (electronic- EQ, EJ)
DC (electronic - EW EY, ED, EA)
DC (electronic- QJ)
202
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Attribute
Cat. No. 700-CF
Min OFF time
[ms]
50
Max. ripple
15%
Latch Attachment Release, 100-FL
AC
DC
[VA/W]
[W]
45/40
25
Coil Consumption
Contact Signal Duration
[min./max]
0.03…15 s
Timing Attachment
at min. time setting
at max. time setting
[ms]
[ms]
10
Reset Time, 100- ETA, 100-ETB
70
Repeat Accuracy
10%
(1) For 9V DC, code ZR, use operating voltage 0.65…1.3 x U .
s
For 24V DC, code ZJ, DJ, or EJ use operating voltage 0.7…1.25 x U .
s
(2) At 110V DC, coil code ED has an operating voltage range of 0.7...1.25 x U .
s
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
203
Relay and Timer Specifications
General Specifications - 700-CF Relays
Cat. No. 700-CF
Rated Insulation Voltage U
i
IEC
690V
600V
6 kV
UL; CSA
Rated Impulse Strength U
imp
High Test Voltage 1 minute (per IEC 60947-
2500V
Rated Voltage U
e
AC
DC
115, 230, 400, 500, 690V
24, 48, 110, 220, 440V
Short-Circuit Protection gG Fuse 20 A
Rated Frequency
50/60 Hz, DC
Ambient Temperature
Storage
–55…+80 °C (–67…+176 °F)
–25…+60 °C (–13…+140 °F)
Operation at nominal current
15% current reduction for AC-12 at > 60 °C
Corrosion Resistance
Altitude
–25…+70 °C (–13…+158 °F)
humid-alternating climate, cyclic, per IEC 60068-2-30 and DIN 50 016, 56 cycles
2000 m above mean sea level, per IEC 60 947-4
Type of Protection
IP2X (IEC 60529 and DIN 40050)
Shock Resistance
in connected state
IEC 60068-2: Half sinusoidal shock 11 ms, 30 G (in 3 directions)
Vibration Resistance
Standards Compliance
IEC 60068-2: Static >2 G, in normal position no malfunction <5 G
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified
Certifications
Utilization Category Table from EN 60947-5-1
Verification of Making and Breaking Capacities of Switching Elements Under Normal Conditions Corresponding to the Utilization Categories (1)
Normal Condition of Use
Number and Rate of Making and Breaking
operations
Make (3)
Break (3)
Utilization
Category
No.
Operating
cycles per
minute
ON time [s]
I/I
U/U
cos φ
I/I
U/U
e
cos φ
operating
(6)
e
e
e
cycles (5)
AC-12 (2)
AC-13 (2)
AC-14 (2)
AC-15 (2)
DC
1
2
1
1
0.9
1
1
1
1
0.9
6050
6050
6050
6050
—
6
6
0.05
0.05
0.65
0.3
0.65
0.3
6
1
1
1
6
0.05
10
—
1
1
0.3
1
1
0.3
6
0.05
—
1
T
—
1
—
1
T
—
6
—
0.95
0.95
DC-12
1 ms
6 x P (4)
1 ms
6 x P (4)
15 ms
6050
6050
6050
0.05 (6)
0.05 (6)
0.05 (6)
DC-13
DC-14 (2)
1
1
1
1
6
10
1
15 ms
1
1
—
(1) See sub-clause 8.3.3.5.2.
(2) Where the break current differs from the make current value, the ON time refers to the make current value after which the current is reduced to the break current value for a suitable period e.g., 0.05 s.
(3) For tolerances on test quantities, see sub-clause 8.3.2.2.
(4) The value ”6 x P”results from an empirical relationship which is found to represent most DC magnetic loads to an upper limit of P = 50 W, e.g., 6 x P = 300 W.
(5) The first 50 operating cycles shall be run at U/U = 1.1 with the loads set at U .
e
e
(6) The ON time shall be at least equal to T
.
0.95
I
U
Rated operational current, I Current to be made or broken
Rated operational voltage, U Voltage before make
e
e
PU I Steady-state power consumption (W)
e
e
T
Time to reach 95% of the steady-state current (ms)
0.95
204
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Contact Rating Table from EN 60947-5-1
Examples of Contact Rating Designation Based on Utilization Categories
Conventional
NEMA
IEC
Utilization
Category
Thermal
Current Ithe
(A)
Designation
Rated Operational Current Ie (A) at Rated Operational Voltage Ue
VA Rating
(1)
AC
120V
6
240V
—
3
380V
—
480V
—
500V
—
—
1.4
600V
—
—
1.2
—
—
0.6
—
—
0.3
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Make
7200
7200
7200
3600
3600
3600
1800
1800
1800
432
Break
720
720
720
360
360
360
180
180
180
72
A150
A300
A600
B150
B300
B600
C150
C300
C600
D150
D300
E150
AC-15
AC-15
AC-15
AC-15
AC-15
AC-15
AC-15
AC-15
AC-15
AC-15
AC-14
AC-14
DC
10
10
10
5
6
—
—
6
3
1.9
1.5
3
—
1.5
—
—
—
—
0.72
—
—
.035
—
—
—
600V
—
—
0.4
5
3
—
—
5
3
1.5
0.95
—
0.75
—
2.5
2.5
2.5
1.0
1.0
0.5
1.5
1.5
1.5
0.6
0.6
0.3
125V
2.2
2.2
2.2
1.1
1.1
1.1
0.55
0.55
0.55
0.22
0.22
—
0.75
0.75
—
0.3
—
—
0.47
—
0.375
—
—
—
432
72
—
250V
—
1.1
—
—
216
36
440V
—
500V
—
Make
275
Break
275
275
275
138
138
138
69
N150
N300
N600
P150
P300
P600
Q150
Q300
Q600
R150
R300
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
DC-13
10
10
10
5
—
—
275
1.1
0.63
—
0.55
—
275
—
0.55
0.55
—
0.27
0.27
—
0.1
—
—
0.2
138
5
—
—
138
5
0.31
—
0.27
—
138
2.5
2.5
2.5
1.0
1.0
—
—
0.1
69
—
—
69
69
0.15
—
0.13
—
69
69
—
—
28
28
—
—
28
28
(1) This letter stands for the conventional thermal current and identifies AC or DC: for example, B=5 A AC. The number that follows is the rated insulation voltage.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
205
Relay and Timer Specifications
Dimensions - 700-CF... Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Mounting Position
AC and DC Control Relay with DC Electronic Coil
(1)
Front View
Side View
(1) May be mounted to 35 mm EN 50 022 DIN Rail.
DC Control Relay
Side View
Front View
All AC Control Relays and DC Control Relays with 12V or 24V DC Electronic Coil
Type
a
b
c
c1
c2
c2
c2
Ød
2 screws 4.5
d1
d1
d1
d2
45
81
80.5
75.5
6
60
35
(1-25/64)
700-CF, -CFB, -CFM
(1-25/32)
(3-3/16)
(3-11/64)
(3-3/32)
(1/4)
(3/16)
(2-23/64)
DC Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil
Type
a
b
c
c1
Ød
d2
d2
45
(1-25/32)
105
(4-1/8)
80.5
(3-11/64)
75.5
(3-3/32)
6
(1/4)
2 screws 4.5
(3/16)
60
(2-23/64)
35
(1-25/64)
700-CF, -CFB, -CFM
DC Control Relays with Conventional Coil
Type
a
b
c
c1
Ød
45
(1-25/32)
81
(3-3/16)
106.5
(4-3/16)
101.5
(4)
6
(1/4)
2 screws 4.5
(3/16)
60
(2-23/64)
35
(1-25/64)
700-CF, -CFB, -CFM
206
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Accessories - 700-CF Relays
Relay with
AC Control Relay
DC Control Relay
mm (inches)
mm
(inches)
(c/c1 + 1 – 37/64)
(a + 23/64)
(c/c1 + 2 – 23/64)
(b + 15/16)
(c/c1 + 2 – 31/64)
(b + 23/64)
(b + 1/8)
Auxiliary Contact for Front Mounting
Auxiliary Contact for Side Mounting
Pneumatic Timing Module
Solid-state Timing Module
Mechanical Latching
DC Interface
2- or 4-pole
1- or 2-pole
c/c1 + 39
a + 9
c/c1 + 39
a + 9
—
c/c1 + 1 – 37/64)
(a + 23/64)
—
—
c/c1 + 58
b + 24
c/c1 + 61
b + 9
on coil terminal side
—
b + 24
—
(b + 15/16)
—
on coil terminal side
on coil terminal side
label sheet
—
—
Surge Suppressor
Labelling with:
b + 3
b + 3
+0
(b + 1/8)
(+0)
+0
(+0)
—
marking tag with cover
marking tag carrier for System V4/V5
+0
(+0)
+0
(+0)
—
+5.5
(+7/32)
+5.5
+5.5
(+7/32)
(+7/32)
—
marking tag carrier for System Bull. 1492W
+5.5
(+7/32)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
207
Relay and Timer Specifications
700S-CF Control Relays
The 700S-CF Safety Control Relay provides mechanically or mirror contact performance, which are required
in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits
where high contact reliability is required.
•
•
•
•
•
•
IEC industrial safety relay
Mechanically linked contacts as per IEC 60947-5-1
Third party certification SUVA
Red cover and mechanically linked contact symbol on front face
Gold plated, bifurcated version for low level switching applications
Permanently fixed front mounted auxiliary contact block
Type CF and CFB Safety Control Relays — 8-Pole AC Coil Voltage (Ratings for 700S-CF Only)
AC-12
AC-15
Contacts
Standard
Contacts
(Main)
Gold-Plated
Bifurcated
(Front)
Connection Diagrams
Gold-Plated
Bifurcated,
All Contacts
Ith [A]
Ie [A]
(1)
Cat. No.
Main
Contacts
Auxiliary
Contacts
Cat. No.
40 60 24/
°C °C 48V
120 240 400 500 600 690
N.O. N.C.
V
V
V
V
V
V
20 20 10
10
10
6
2.5
1
1
700S-
CF440⊗BC
700S-
CFB440⊗C
4
4
Main
Contacts
700S-
700S-
5
6
3
2
CF530⊗BC
CFB530⊗C
10
6
6
6
5
3
1.6
1
1
Adder
Deck
Contacts
700S-
CF620⊗BC
700S-
CFB620⊗C
(1) Ratings for 700S-CFB are on Specifications
⊗ AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440⊗BC
becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz.
[V]
12
24
32
36
42
48
100
100... 110
110
120
127
200
200... 208
220
208... 220...
240
—
L
230
50 Hz
60 Hz
R
K
V
W
V
X
Y
KP
—
KP
—
KP
D
P
S
KG
—
KG
L
—
H
F
Q
J
—
—
—
—
X
—
KD
D
—
—
KG
KL
—
KL
50/60
Hz
—
KJ
—
KY
—
—
—
—
[V]
230
230...
240
240
277
347
380
380...
400
400
400...
415
440
480
500
550
600
50 Hz
60 Hz
—
—
VA
T
—
T
—
I
—
E
N
—
—
KN
G
B
—
B
M
C
—
C
—
—
A
—
—
—
—
N
—
—
—
—
50/60 Hz KF
KA
—
—
—
KB
—
—
208
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Type CF and CFB Safety Control Relays — 8-Pole DC Coil Voltage (Ratings for 700S-CF Only)
AC-12
AC-15
Contacts
Ith [A]
Ie [A]
Connection Diagrams
Standard
Contacts
(Main)
Gold-
Gold
Plated
Bifurcated
All
Plated
Bifurcated Contacts
(Front)
Cat. No.
Cat. No.(1)
Main
Contacts
Auxiliary
Contacts
No. of
N.O.
No. of
N.C.
40 60
°C °C
24/48V 120V 240V 400V 500V 600V 690V
Contacts Contacts
20 20 10
10
10
6
2.5
1
1
4
5
6
4
3
2
700S-
700S-
CF440⊗BC CFB440⊗C
Main
Contacts
700S-
700S-
CF530⊗BC CFB530⊗C
Adder
Deck
Contacts
10
6
6
6
5
3
1.6
1
1
700S-
700S-
CF620⊗BC CFB620⊗C
(1) Ratings for 700S-CFB are on Specifications
⊗DC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CFB440⊗C
becomes Cat. No. 700S-CFB440EJC for 24V DC, electronic with diode.
48...
72
110...
125
220...
250
[V]
9
12
24
36
48
60
64
72
80
110
115 125 220
230 250
Electronic with
diode
—
EQ
EJ
EW
—
EY
—
—
—
—
—
ED
—
—
—
—
—
—
EA
—
—
—
—
Electronic with
diode/ Quick
Pick-up
—
—
QJ
—
—
—
—
—
—
—
—
—
—
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
209
Relay and Timer Specifications
Assignment of Contacts
Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage
53 61 71 81
61
61
73 83
71 83
53
53
54 62 72 82
54 62 72 84
21
54 62 74 84
21
13
A1
A1
A1
21
33 43
33 43
33 43
13
13
K1
K1
K1
A2 14 22 34 44
A2 14 22 34 44
A2 14 22 34 44
700S-CF440…
700S-CFB440…
700S-CF530…
700S-CFB530…
700S-CF620…
700S-CFB620…
Specifications - 700S-CF Relays
For more 700S-CF Specifications, see Specifications - 700-CF..., 700S-CF Relays on page 200.
Cat. No.
700S-CF
Aux. Contact
(Front-mounted)
Mechanical Life
Electrical Life
[Mil]
[Mil]
[g]
15
1.5
390
15
1.5
—
AC-15 (240V, 3 A)
AC Coil
Weight
Terminal Cross-Sections
Terminal Type
Terminal Size per IEC 947-1
2 x A4
1.5…6
2 x A4
0.5…2.5
0.75…2.5
18…14
2
1 Conductor
2 Conductor
[mm ]
Solid/ Stranded (1)
[mm2]
[AWG]
[lb•in]
[N•m]
1.5…6
Max. Wire Size per UL/CSA
Tightening Torque
16…10
13.3…22
1.5…2.5
8.9…13.3
1…1.5
Tightening Torque
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for
European Directive 2002/95/EC - EU-RoHS
Standards Compliance
Certifications
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified
(1) For 16 or more strands, end ferrule is required
210
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Dimensions - 700S-CF Relays
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
c2
c1
c
AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil
Cat. No.
a
b
c
c1
c2
Ød
d1
d2
45
81
119.5
114.5
6
2 - 4.5
60
35
700S-CF
(1-25/32)
(3-3/16)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil
Cat. No.
a
b
c
c1
c2
Ød
d1
d1
d2
d2
45
105
119.5
114.5
6
2 - 4.5
60
35
700S-CF
(1-25/32)
(4-1/8)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
DC Safety Control Relays with Conventional Coil
Cat. No.
a
b
c
c1
c2
Ød
45
81
145.5
140.5
6
2 - 4.5
60
35
700S-CF
(1-25/32)
(3-3/16)
(5-49/64)
(5-37/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
Accessories - 700S-CF Relays
Safety Control Relays with
mm
[in.]
Auxiliary contact block for side mounting 1- or 2-pole
Electronic Timing Module on coil terminal side
Interface Module on coil terminal side
Surge Suppressor on coil terminal side
Labeling with label sheet
a + 9
b + 24
b + 9
b + 3
+ 0
(a + 23/64)
(b + 15/16)
(b + 23/64)
(b + 1/8)
(+ 0)
Marking tag sheet with clear cover
+ 0
(+ 0)
Marking tag adapter for System Bul. 1492W
+ 5.5
(+ 7/32)
Mounting Position
AC and DC E Safety Control Relays
DC Safety Control Relays
Side View
Side View
Front View
Front View
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
211
Relay and Timer Specifications
Safety Relay Circuit With 5 Safety Outputs
•
Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open
connection such as a loose wire).
•
•
•
•
High output switching capability and long contact life.
Circuit complies with EN 954 categories 1, 2, 3, 4.
Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system.
Use (3) 700S-CF relays and this diagram to construct the circuit
Basic Circuit
(1) Output Circuit (3 Relays, 9 Terminal Blocks)
Start
Push To Stop
Pull To Reset
Included in factory
wired units
LOAD 1
(5) Output Circuit (3 Relays, 17 Terminal Blocks)
LOAD 2
LOAD 3
LOAD 4
LOAD 5
*
Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.
212
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-K Miniature Control Relays
•
•
•
•
IEC compact industrial relay
IP2X Finger Protection
Bifurcated contacts for low-level signals
Optional integrated coil protection diode
4-Pole AC or DC Coil Voltage
AC-12
AC-15 (B600)
Contacts
Pkg.
Connection
Diagrams
Ith [A]
Ie [A]
Qty.(2)
Cat. No.
40 °C 60 °C 24/48V
120V
240V
400V
500V
600V
690V
N.O.
N.C.
4
0
1
1
1
1
700-K40E-⊗
700-K31Z-⊗
700-K22Z-⊗
700-KL22Z-⊗
3
2
1
2
10
6
3
3
2
1
1
0.6
0.6
1+1L (1) 1+1L
(1) 1L = Late Break N.C. / Early Make N.O.
(2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM.
⊗ Coil Voltage Codes
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700-
K40E-⊗ becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
For Screw Type Terminal Versions
[V]
12
24
—
—
KJ
110
D
120
—
D
125
—
—
—
ZS
220
—
—
—
ZA
230
—
—
KF
240
—
—
KA
250
—
—
—
ZT
400
—
—
KN
440
B
480
—
B
525
VC
600
—
VC
AC, 50 Hz
—
—
—
ZQ
AC, 60 Hz
—
—
ZD
—
—
—
—
—
—
—
—
AC, 50/60 Hz
Standard
—
—
—
—
—
—
—
—
—
ZJ
—
—
—
—
—
—
DC
Standard diode
—
DJ
—
—
—
—
For Spring Clamp Type Terminal Versions
AC, 50 Hz
—
—
—
—
—
—
—
KJ
D
—
D
—
—
—
—
—
—
—
—
—
—
—
—
KF
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
AC, 60 Hz
—
—
ZD
—
AC, 50/60 Hz
Standard
—
—
—
ZJ
—
—
DC
Standard diode
DJ
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
213
Relay and Timer Specifications
Assignment of Contacts
Device Combinations in Accordance with IEC 60947-1 / -4-1
Table valid for: AC / DC = 0.85…1.1 x U , T . = -25 °C…+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and
s
amb
(3)
100-KR auxiliary contacts.
Auxiliary Contact Blocks
Control Relays 700-K (AC and DC Control)
700-K31Z- 700-K40E-
Cat. No.
Circuit Diagram
Control
700-K22Z-
700-KL22Z-
43
47
21 35
13
21 31
33
23
13
A1
A1
13
43 21
13
33 43
A1
A1
22
22
36
A2 14 44
32
44
34
A2 14 48
A2 14 34
22
A2 14 24
44
Front Mounting
51 61
100-KFA02E
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
AC/DC
—
31Z + 02E = 33Y (1)
31Z + 11E = 42Y
31Z + 20E = 51Y
—
40E + 02E = 42Y
40E + 11E = 51Y
40E + 20E = 60Y
40E + 04E = 44Y (1)
40E + 13E = 53Y
40E + 22Z = 62Y
40E + 31Z = 71Y (2)
40E + 40E = 80Y
—
52 62
53 61
100-KFA11E
100-KFA20E
100-KFA04E
100-KFA13E
100-KFA22Z
100-KFA31Z
22Z + 11E = 33Y
L22Z + 11E = L33Y
54 62
53 63
22Z + 20E = 42Y
L22Z + 20E = L42Y
54 64
51 61 71 81
—
—
52 62 72 82
53
61 71 81
—
31Z + 13E = 44Y (1)
31Z + 22Z = 53Y (1)
—
—
54 62 72 82
53 83 61
71
—
—
—
—
54 84 62 72
53 73 83 61
54 74 84 62
63 73 83
53
100-KFA40E
22Z + 40E = 62Y
31Z + 40E = 71Y
L22Z + 40E = L62Y
54 64 74 84
(1) Tamb. max. +40 °C
(2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC
(3) For other operating limits, please contact our technical consultant.
214
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Auxiliary Contact Blocks
Photo
Description
Connection
Diagrams
For Use With Pkg.
Screw Type
Terminals
Spring Clamp
Terminals
Qty.
(1)
N.O.
N.C.
Cat. No.
Cat. No.
51 61
100/104-K,
700-K
0
2
1
100-KFA02E
100-KRFA02E
52 62
53 61
100/104-K,
1
2
0
1
2
3
4
1
0
4
3
2
1
0
1
100-KFA11E
100-KFA20E
100-KFA04E
100-KFA13E
100-KFA22Z
100-KFA31Z
100-KFA40E
100-KRFA11E
100-KRFA20E
100-KRFA04E
100-KRFA13E
100-KRFA22Z
100-KRFA31Z
100-KRFA40E
700-K
54 62
53 63
100/104-K,
700-K
1
54 64
Front-mounted auxiliary contacts
51 61 71 81
100/104-K,
700-K
•
•
•
•
•
Auxiliary Contact Blocks
1
2- and 4-pole versions
52 62 72 82
Choice of contact configurations
Snap on, no tools required
53
61 71 81
100/104-K,
700-K
Electronic-compatible bifurcated contacts
for signals down to 15V / 2 mA
1
54 62 72 82
53 83 61
71
100/104-K,
700-K
1
54 84 62 72
53 73 83 61
100/104-K,
700-K
1
54 74 84 62
63 73 83
53
100/104-K,
700-K
1
54 64 74 84
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFA02EM.
Control Modules
Description
Photo
Connection
Diagrams
For Use With Pkg.
Qty.
Cat. No.
Mechanical Interlock
•
•
•
•
For interlocking of two adjacent contactors
No added width to contactor assembly
Front mount plug-in type
Optional auxiliary contact blocks and suppressor modules mount
onto the interlock
100/104-K/-
KR,
1
100-KMCH
700-K/- KR
24…48V AC
110…280V AC
380…480V AC
1 (1) 100-KFSC50
1 (1) 100-KFSC280
1 (1) 100-KFSC480
100/104-K/-
KR,
700-K/- KR
RC Suppressor
12…55V AC,
12…77V DC
1 (1) 100-KFSV55
1 (1) 100-KFSV136
1 (1) 100-KFSV277
SurgeSuppressor
•
•
Plug-in type
100/104-K/-
KR,
56…136V AC,
78…180V DC
Limits surge voltage on
coil drop-off
MOV Suppressor
Diode Suppressor
700-K/- KR
137…277V AC,
181…250V DC
100/104-K/-
KR,
700-K/- KR
12…250V DC
1 (1) 100-KFSD250
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
215
Relay and Timer Specifications
Accessories
Pkg.
Qty.
Photo
Description
Cat. No.
Label Sheet
105 self-adhesive paper labels each, 6 x 17 mm
10
100-FMS
Snap-In Marker Card
5
1492-M6X12
216
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
IEC Specifications - 700-K... Relays
700-K
700-KR
AC-12 Rated Thermal Current Ambient temperature 40°C
I
24…240V
230…500V
230…690V
[A]
[A]
[A]
10
10
10
th
Ambient temperature 60°C
I
24…240V
230…500V
230…690V
[A]
[A]
[A]
6
6
6
th
AC-15/B600 Switching of Solenoids and contactors
I
24V
48V
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
3
3
e
120V
230V
240V
400V
480V
500V
600V
690V
3
2
2
1.2
1
1
0.6
0.6
Short-circuit Protection
Fuse gG
[A]
10
2
Min. Switching Capacity 15V
[mA]
Resistance and Power Dissipation
Main current circuit resistance, 1 pole
Power dissipation, 4 poles
[mΩ]
6.5
2.6
[W]
Total power dissipation
AC control, warm
DC control, warm
[W]
[W]
4.4
5.2
Lifespan
Mechanical
[Mio. op.]
[Mio. op.]
15
Electrical AC-15 (240V / 2 A)
Weight
0.7
AC control
DC control
kg (lbs.)
kg (lbs.)
0.16 (0.35)
0.2 (0.44)
Load Carrying Capacity per UL/CSA
Rated voltage
AC
40 °C
AC
[V]
[A]
[A]
[V]
[A]
max. 600
Continuous rating
Switching capacity
Rated voltage
10
6
B 600
max. 600
Q 600
DC
Switching capacity
DC
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
217
Relay and Timer Specifications
700-K
DC-13/Q600
1 pole
24V
48V
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
2.3
1
110V
125V
220V
250V
400V
440V
600V
0.55
0.55
0.27
0.27
0.15
0.15
0.1
Cross Sections
Conductor Cross Sections
700-K
700-KR
- Main Contacts, Auxiliary Contacts, and Coil Terminals
(1)
Terminal type
2
(1) Conductor
Fine stranded with ferrule
(2) Conductors
[mm ]
0.75…2.5
0.75…2.5
0.50…2.5
0.50…2.5
[mm2]
0.75…2.5 (3)
0.75…2.5 (3)
2
(1) Conductor
Solid or coarse stranded
[mm ]
1…4
1…2.5 + 1…4
(2) Conductors
[mm2]
Recommended torque
Cross section per UL/CSA
Recommended torque
[Nm]
[AWG]
[lb-in]
1.2
18…12 (2)
10.6
—
18…14 (3)
—
(1) Pozidriv No. 2 / Blade No. 3 screw
(2) Use same cross sections
(3) Stranded wire only
218
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Coil Data
700-K
Operating Limits
pick-up
dropout
[x Us]
[x Us]
0.85…1.1
0.2…0.75
0.8…1.1
AC control
50 Hz, 60 Hz, 50/60 Hz
pick-up
dropout
[x Us]
[x Us]
9, 12, 24, 110V DC: 0.7…1.25
DC control
0.1…0.75
Coil Consumption
pick-up
hold-in
pick-up
hold-in
[VA/W]
[VA/W]
[W]
35/32
AC control
50 Hz, 60 Hz, 50/60 Hz
5/1.8
cold 3.0, warm 2.6
cold 3.0, warm 2.6
DC control
Operating Times
AC
[W]
closing delay
opening delay
opening delay
closing delay
opening delay
closing delay
opening delay
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
15…40
15…33
15…28
18…40
6…12
With RC module
DC
With integrated diode
With external diode
8…12
35…50
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
219
Relay and Timer Specifications
Dimensions - 700-K... Relays
Approximate dimensions are shown in millimeters. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for
manufacturing purposes.
(mm)
180°
)
12
*
35
45
4
35.2
49
)
-Minimum distance to grounded parts or walls
*
79
220
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Solid-state Relays
Product Overview
Bulletin No.
Type
700-SA
700-SC
Tube Base, Socketed
Miniature, Ice Cube Socketed
Compatible with 700-HN100, 125,108, and 204 socket, LED Compatible with 700-HN103 or 128 socket, LED Status, and Zero-
Features
status, zero-cross switching
cross AC Switching Options
AC
Load Type
DC
AC (47…63 Hz)
DC
(47…63 Hz)
Load Voltage Range
75…264V AC
5 A
3…125V DC
3 A
75…264V AC
3 A
3…52.8V DC or 3…125V DC
3 A @ 48V DC or 2 A @ 110V DC
Load Current Max. (Continuous)
10 mA @ 200V AC, 5 mA @ 50V DC
or 0.1 mA @ 100V DC
Max. Leakage Current to Load
Zero Cross Load Switching
5 mA @ 100V, 10 mA @ 200V
5 mA @ 125V
5 mA @ 100V AC
Yes (optional)
Form A
Yes
Not Applicable
Not Applicable
Equivalent Electromechanical Relay
Contact Arrangement
Form A
5…24V DC, 100…110V
AC, 200/220V AC
Rated Control (Input) Voltage
5…24V DC
5...24V DC
LED Indicator
Yes
Yes (optional)
Yes (optional for 48V DC)
Mounting Method
Dielectric Strength
Certification
Panel or DIN with socket
1500V AC, 50/60 Hz, 1 min.
cURus, CE, VDE
Panel or DIN with socket
1500V AC, 50/60 Hz, 1 min.
cURus, CE, VDE
Max. Ambient Operating Temperature
Page
-30…80 °C (no condensation)
223
-30…80 °C (no condensation)
228
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
221
Relay and Timer Specifications
Product Overview
Bulletin No.
Type
700-SF
700-SH
700-SK
Square Base, Socketed
Hockey Puck
Slim Line, Socketed
Compatible with 700-HN116 socket,
LED status, zero-cross AC switching
Panel/DIN Mount, High Current,
Protective Cover, LED Status
Compatible with 700-HN121 socket. Supports Input (sensor) module or
Output (SSR) module
Features (1)
Output Module
Input Module
AC (47…63 Hz)
3…60V DC
Load Type
AC (47…63 Hz)
DC
AC
DC
AC (47…63 Hz) DC
(47…63 Hz)
3…50V DC, 24…265V AC
42…530V AC, 42…265V AC,
42…660V AC
4 … 60V
DC, 40 …
200V DC
Load Voltage
Range
Field Input: 60… Field Input:
75…264V AC
3 A
3 … 52.8V DC
75 … 264V AC
2 A
264V AC
6.6… 32V DC
Load Current
Max.
(Continuous)
2 A @ 60V,
1.5 A @
200V
Supply Current:
0.1…100 mA
Supply Current:
0.1…100 mA
10 A/100 A‡
<3 mA
Yes
Max. Leakage
Current to
Load
5 mA @ 100V AC,
10 mA @ 200V AC
5 mA @ 50V DC
Not Applicable
1.5 mA
1 mA
N/A
5 μA
5 μA
Zero Cross
Load
Yes
Yes (optional)
No
N/A
Switching
Equivalent
Electromecha
nical Relay
Contact
Form A
Form A
Form A
Arrangement
Rated Control
(Input)
Voltage
3…32V DC, 4…32V DC,
80…130V AC, 20…260V AC
20…280V AC/22…48V DC
4V DC or 24V DC
5… 24 V DC
Yes
LED Indicator Yes
Yes
Mounting
Method
Panel without heat sink, Panel, or DIN
with heat sink
Panel or DIN with socket
1500V AC, 50/60 Hz, 1 min.
Panel or DIN with socket
Dielectric
Strength
>4000V AC RMS
cURus, CE, CSA
4000V AC, 50/60 Hz, 1 min.
cURus, CE, TÜV
Certification cURus, CE, VDE
Max. Ambient
Operating
Temperature
-30…80 °C (no condensation)
-20…70 °C (no condensation)
237
-30…80 °C (no condensation)
246
Page
233
(1) See Solid-state Relay Glossary on page 223 for term definitions.
222
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Solid-state Relay Glossary
Terms
Meaning
Basic insulation
Insulation for basic protection from electric shock (IEC950 1.2.9.2)
Independent insulation that is provided outside of basic insulation to protect from electric shock when the basic
insulation breaks down (IEC950 1.2.9.3)
Supplemental insulation
Reinforced insulation
Insulation
A single-layer of insulation (IEC950 1.2.9.5) that provides the same protection from electric shock as double insulation
(insulation including both basic and supplemental insulation) according to conditions stipulated in IEC950 standards
Zero cross circuit
Trigger circuit
A circuit that starts operation with the AC load voltage at close to zero-phase.
Circuit functions
A circuit for controlling the triac or thyristor trigger signal, which turns the load current ON and OFF.
If the external circuit is prone to generating noise, or if wires from external sources are prone to the influence of
inductive noise, in order to prevent malfunctions due to noise, it is necessary to electrically isolate internal circuits and
external circuits (output circuits). An isolated input circuit is a circuit that isolates inputs and outputs by using
components that are not connected electrically but that can transmit signals, such as contact relays or photocouplers.
Isolated input circuit
A component that runs the electric signal into a light emitter (for example, LED), changes it to a light signal, and then
returns it to an electric signal using a photoelectric conversion element, such as a photo transistor. The space that is
used for transferring the light signal is isolated thus providing good insulation and a high propagation speed.
Photocoupler
Rated voltage
The voltage that serves as the standard value of an input signal voltage
Input
Pickup (must-operate) voltage Minimum input voltage when the output status changes from OFF to ON.
The impedance of the input circuit and the resistance of current-limiting resistors used. Impedance varies with the
Input impedance
input signal voltage in case of the constant current input method.
The permissible voltage range within which the voltage of an input signal voltage may fluctuate.
Maximum input voltage when the output status changes from ON to OFF.
The current value when the rated voltage is applied.
Operating voltage
Dropout (Reset) voltage
Input current
This is the effective value for the power supply voltage that can be used for load switching or in the continuous-OFF
state.
Load voltage
The effective value of the maximum current that can continuously flow into the output terminals under specified
cooling conditions (i.e., the size, materials, thickness of the heat sink, and an ambient temperature radiating
condition).
Maximum load current
(continuous)
The effective value of the current that can flow into the output terminals when a specified load voltage is applied to
the SSR with the output turned OFF.
Leakage current
The effective value of the AC voltage that appears across the output terminals when the maximum load current flows
through the SSR under specified cooling conditions (such as the size, material, and thickness of heat sink, ambient
temperature radiation conditions, etc.).
Output ON voltage drop
Output
Minimum load current
(continuous)
The minimum load current at which the SSR can operate normally.
A circuit consisting of a resistor R and capacitor C, which prevents faulty ignition from occurring in the SSR triac by
suppressing a sudden rise in the voltage that is applied to the triac.
Snubber circuit
Semiconductor output
This is a generic name for semiconductors such as the thyristor, triac, power transistor, and power MOS FET. In
element (switching element) particular, triacs are often used in SSRs because they allow switching to be performed with one element.
Repetitive peak OFF-state
This is a rating for an output semiconductor that used in an SSR for AC loads.
voltage (VDRM)
Collector-emitter voltage
This is a rating for an output semiconductor that used in an SSR for DC loads.
(VCEO)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
223
Relay and Timer Specifications
Terms
Meaning
A time lag between the moment a specified signal voltage is imposed to the input terminals and the output is turned
ON.
Operating (pick-up) time
Release (drop-out) time
Insulation resistance
A time lag between the moment the imposed signal input is turned OFF and the output is turned OFF.
The resistance between the input and output terminals or I/O terminals and metal housing (heat sink) when DC
voltage is imposed.
Characteristics
The effective AC voltage that the SSR can withstand when it is applied between the input terminals and output
terminals or I/O terminals and metal housing (heat sink) for more than 1 minute.
Dielectric strength
Ambient temperature and
humidity (operating)
The ranges of temperature and humidity in which the SSR can operate normally under specified cooling, input/output
voltage, and current conditions.
Storage temperature
The temperature range in which the SSR can be stored without voltage imposition.
A current, which can be applied for short periods of time to the electrical element.
Extremely steep voltage rise which occurs when the load switched or turned OFF.
Inrush current resistance
Counter-electromotive force
The recommended load capacity which takes into account the safety factors of ambient temperature and inrush
current.
Others
Recommended applicable load
Bleeder resistance
The resistance connected in parallel to the load in order to increase apparently small load currents, so that the ON/OFF
of minute currents functions normally. (It is also used to shunt leakage currents.)
Solid-state Relay Switching Capacity
Maximum AC and DC Switching Capability
Equivalent EM
Relay Contact
Configuration
Load
Load
Voltage
Relay Type
Zero-Cross Switching 1 mA 10 mA 50 mA 100 mA 1 A
3 A
5 A
10 A 20 A 25 A 30 A 35 A
100 A
Device
AC
DC
AC
DC
AC
DC
AC
DC
AC
DC
Yes
N/A
Yes
N/A
Yes
N/A
Yes
N/A
Yes
N/A
Triac
Transistor
Triac
Form A
Form A
700-SA
700-SC
Transistor
Triac
(2 A)
700-SF
Form A
Form A
Transistor
Thyristor
or Triac
Transistor
700-SH *
Triac
(2A)
700-S KO
Form A
Transistor
IMPORTANT * Requires a heat sink to reach maximum current value.
224
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-SA Tube Base Relays
•
•
•
•
•
•
5 A (resistive) max. continuous load (output) current
264V AC or 125V DC max. load voltage options
Photocoupler isolation between control and load voltage
LED indicator (standard) for input/logic ON/OFF status monitoring
700-HN100, -HN125, -HN 202, or -HN108 specialty socket compatible
700-HT2 timing module
Input-to-Output Isolation
Method
Output (Load) Max. Continuous
Current and Rated Voltage Range Voltage
Rated Input (Control)
Zero Cross Function Status Indicator
Cat. No.
5 A @ 100…240V AC
Yes
700-SAZY5Z25
700-SANY3Z25
(47…63 Hz)
Photocoupler
Yes
5…24V DC
Not Applicable
3 A @ 5…110V DC
Accessories - 700-SA Relays
Photo
Description
Pkg. Quantity
Cat. No.
10
700-HN100
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.
8 Pin for use with DPDT 700-HA Relays.
10
10
700-HN108
700-HN125
Specialty Socket
8 Pin back wired socket with solder terminals
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8 Pin
for use with DPDT 700-HA Relays. No retainer clip required.
10
199-DR1
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains
13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with
sticky backing for easy placement on relays.
10
10
10
700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on
relays.
700-N41
700-HN158
Retainer Clip for Sockets with 700-SA AND 700-HB Relays. Secures relay in socket.
10
700-HN204
8-Pin Socket — Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal
Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT 700-HA
Relays.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
225
Relay and Timer Specifications
Specifications - 700-SA Relays
Control/Input Ratings
Cat. No.
Rated Control
Max. Operating
Control
Max. Reverse
Control
Impedance
Control Voltage Levels
Voltage
Pick-up Voltage
Drop-out Voltage
Voltage Range
Voltage
(1)
700-SAZY5Z25
700-SANY3Z25
4…32V DC
4…30V DC
-32V DC
-30V DC
15 mA max.
5…24V DC
4V DC max.
1V DC min.
1.5 kΩ (+20% -10%)
Load/Output Ratings
Cat. No.
Rated Load
Voltage
Maximum Load
Continuous Load Current (Resistive) [A]
(2)
Max. Inrush
(3)
Voltage Range
Current
Min.
0.1
Max.
5.0
80 A, @ 50/60 Hz for 1
cycle
700-SAZY5Z25
700-SANY3Z25
100…240V AC
5…110V DC
75…264V AC
3…125V DC
0.1
3.0
12 A (10 ms)
Characteristics
Description
Cat. No. 700-SAZY5Z25
Triac
Cat. No. 700-SANY3Z25
Load Switching Method/Device
Pick-up Time
Transistor
(4)
1/2 cycle of load power source cycle time + 1 ms max.
0.5 ms max.
(4)
Drop-out Time
1/2 cycle of load power source cycle time + 1 ms max.
2.5 ms max.
Output ON Voltage Drop
Output Leakage Current
1.6V (RMS) max.
1.5V max.
5 mA max. (at 100V AC); 10 mA max. (at 200V AC)
5 mA max. (at 125V DC)
Output V
V
(V)
600
50
150
—
—
—
150
DRM CEO
Output di/dt (V/uS)
Output dv/dt (V/uS)
500
41.6
125
2
2
Output I t (A S)
Output Tj (ºC) Max.
Insulation Resistance
Dielectric Strength
100 MΩ min. (at 500V DC)
1500V AC, 50/60 Hz for 1 min
Vibration Resistance (Max.)
Shock Resistance (max.)
10…55 Hz, 1.5 mm double amplitude (10 G)
2
1000 m/s (100 G)
Operating
Storage
–30…80 °C (–22…176 °F) with no icing or condensation
–30…100 °C (–22…212 °F) with no icing or condensation
45…85% (no condensation)
Ambient Temperature
Ambient Humidity
Standards Compliance
Certifications
UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Approx. 70 g
Weight
(1) With constant current input system. SSR input impedance varies with a change in input (control) voltage.
(2) See the following graph “Load Current Vs. Ambient Temperature Characteristics”for additional load current details.
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity”graph.
(4) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms.
(1)
Load Current vs. Ambient Temperature Characteristics
Inrush Current Resistivity
700-SA
700-SA
80
700-SAZY5Z25
5
70
60
4
50
40
700-SANY3Z25
3
700-SAZY5Z25
700-SANY3Z25
30
20
10
0
2
1
0
Energizing Time [ms]
Ambient Temperature [° C]
(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it
occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
226
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Terminal Arrangement (Bottom View)
Load
Load
Load
power
supply
Input
Input voltage
Note: The plus and minus symbols shown in parentheses
are for DC loads.
Basic Application Considerations
High Density Mounting of Multiple Solid-state Relays (SSRs)
If multiple SSRs are installed side by side,, the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately
ventilated. If poor ventilation is unavoidable, reduce the load current to half.
Protective Component
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in
surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.
Select a varistor that meets the conditions of the load voltage that is outlined in the table.
Load Voltage
100…120V AC
200…240V AC
380…480V AC
Varistor Voltage [V]
240…270
Varistor Surge Resistance
440…470
1000 A min.
820…1000
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.
EMC Directive Compliance
1. AC-switching models comply with EMC Directives
under the following conditions:
Load
Load power
supply
3 m max.
Input
SSR
Load
Input 700-SA Output
Varistor
Film Capacitor
Varistor: 470 V, 0.6 W
Film Capacitor: 1µ F, 250 VAC
• Connect a varistor between the output terminals.
• Connect a film capacitor to the load power supply.
• The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives
under the following conditions:
Less than 10 m
Input
Load
700-SA Output
• The input cable must be less than 10 m.
Dimensions - 700-SA Relays
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for
manufacturing purposes.
(1)
700-SA
+
35
max.
+
52.5
max.
35
max.
(1) 700-SA is compatible with Cat. Nos. 700-HN100, -108, -125, and -204 (sockets).
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
227
Relay and Timer Specifications
700-SC Ice Cube Relays
•
•
•
•
•
•
3 A (resistive) max. continuous load (output) current
264V AC, 48V DC or 125V DC max. load voltage options
5…24V DC or 110/220V AC control (input) voltage options
LED indicator (optional) for input/logic On/Off status monitoring
700-HN103, 700-HN104, or 700-HN128 socket compatible
Compatible with 700-AT1 or 700-AT2 timer modules
Input-to-Output Isolation
Method
Output (Load) Max. Continuous
Current and Rated Voltage Range Voltage
Rated Input (Control)
Zero Cross Function Status Indicator
Cat. No.
3 A @ 100…240V AC(1)
2 A @ 100…240V AC(1)
5…24V DC
100/110V AC
200/220V AC
24V DC
700-SCZY3Z25
700-SCZY2A1
700-SCZY2A2
700-SCTY3Z24
700-SCNY3Z25
700-SCZN3Z26
700-SCTN3Z24
700-SCNN3Z26
700-SCNN2Z25
Photocoupler
Yes
Yes
Phototriac
Photocoupler
Phototriac
No
3 A @ 100…240V AC (1)
3 A @ 4…48V DC
Not Applicable
Yes
5…24V DC
4…24V DC
24V DC
(1)
3 A @ 100…240V AC
No
No
3 A @ 4…48V DC
2 A @ 5…110V DC
4…24V DC
5…24V DC
Photocoupler
(1) 47…63 Hz
Not Applicable
Accessories - 700-SC Relays
Photo
Description
Pkg. Quantity Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith
=
=
10
10
700-HN103
700-HN104
10 A per pole. 14-blade miniature socket for use with 700-SC Relays.
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Ith
10 A per pole. 14-blade miniature socket for use with 700-SC relays. This socket has coil and
contact separation and the ability to plug in optional plug-in modules (700-A__ accessories: LED,
Surge Suppression, Timing Modules)
Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open-Style Construction Ith
=
10
10
700-HN128
199-DR1
10 A per pole. 14-blade miniature socket for use with 700-SC Relays.
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
228
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Photo
Description
Pkg. Quantity Cat. No.
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. 10
Tags are peel-off with sticky backing for easy placement on relays.
700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
700-N41
(1)
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC
Relays. Secures relay in socket.
10
700-HN114
(1) Series B retainer clip must be used with 700-SC
Specifications- 700-SC Relays
Control/Input Ratings
Cat. No.
Rated Control
Voltage
Max. Operating
Control Voltage
Range
Max. Reverse
Control Voltage [V]
Impedance
Control Voltage Levels
Pick-up Voltage
Drop-out Voltage
700-SCZY3Z25
700-SCZY2A1
700-SCZY2A2
700-SCTY3Z24
5…24V DC
100/110V AC
200/220V AC
24V DC
4…28V DC
75…125V AC
150…250V AC
19.2…28.8V DC
-28.8
NA
15mAmax.(1)
41 kΩ 20%
72 kΩ 20%
2 kΩ 20%
4V DC max.
75V AC max.
150V AC max.
19.2V DC max.
1V DC min.
20V AC min.
40V AC min.
NA
-28.8
1.5 kΩ +20%/ -10%
700-SCNY3Z25
5…24V DC
4…28V DC
-28
4V DC max.
(2)
700-SCZN3Z26
700-SCTN3Z24
700-SCNN3Z26
700-SCNN2Z25
Load/Output Ratings
Cat. No.
4…24V DC
24V DC
3…28V DC
-28.8
-28.8
-28
15mAmax. (1)
3V DC max.
1V DC min.
19.2…28.8V DC
2 kΩ 20%
19.2V DC max.
4…24V DC
5…24V DC
1.5 kΩ +20%/ -10%
3…28V DC
3V DC max.
(2)
-28.8
Rated Control
Voltage
Max. Load
Continuous Load Current (Resistive) [A]
Max. Inrush
Current (4)
Min.
Max. (3)
Voltage Range
700-SCZY3Z25
700-SCTY3Z24
700-SCZN3Z26
700-SCTN3Z24
700-SCZY2A1
700-SCZY2A2
700-SCNN3Z26
700-SCNY3Z25
700-SCNN2Z25
0.1
3
45 A (@50/60 Hz,
1 cycle)
100…240V AC
75…264V AC
0.1
2
4…48V DC
3…52.8V DC
3…125V DC
0.1
0.1
3
2
18 A (10 ms)
10 A (10 ms)
5…110V DC
(1) With constant current input circuit system. SSR impedance varies with a change in input (control) voltage.
(2) Input impedance attains its maximum at the operating voltage.
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity”graphs on page 112 for details
(4) See the following “Load Current Versus Ambient Temperature Characteristics”graphs on page 112 for additional load current details.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
229
Relay and Timer Specifications
Characteristics
Description
Cat. No. 700-SCZ…
Cat. No. 700-SCT
Cat. Nos. 700-SCNY, 700-
SCNN3…
Cat. Nos. 700-SCNN2…
Load Switching Method/Device
Triac
Transistor
1/2ofloadpowersourcecycle
time (1) + 1 ms max. (DC
input)
Pick-up time
3/2ofloadpowersourcecycle
(1)
time + 1 ms max. (AC
input)
1/2 of load power source cycle
(1)
time + 1 ms max. (DC input)
3/2 of load power source cycle
1/2 of load power source cycle
Drop-out time
2 ms max.
2.5 ms max.
(1)
time + 1 ms max.
(1)
time + 1 ms max. (AC input)
Output On Voltage Drop
Output Leakage Current
1.6V (RMS) max.
1.6V (RMS)
1.5V max.
1.5V max.
5 mA max (@ 100V AC)
10 mA max (@ 200V AC)
2.5 mA max (@ 100V AC)
5 mA max (at 200V AC)
5 mA max (@ 50V DC)
0.1 mA max (@ 100V DC)
Output V , V (V)
600
50
600
50
80
—
—
—
150
80
—
—
—
150
DRM CEO
Output di/dt (A/uS)
Output dv/dt (V/uS)
250
18
250
18
2
2
Output I t (A S)
Output Tj (°C) Max.
125
125
Insulation Resistance
Dielectric Strength
100 MΩ min (@500V DC)
1500V AC, 50/60 Hz for 1 minute
Vibration Resistance (max.)
Shock Resistance (max.)
10…55 Hz, 1.5 mm double amplitude (10 G)
2
1000 m/s (100 G)
Operating: -30…+80 °C (-22...+176 °F) with no icing or condensation Storage: -30…+100 °C (-22...+212 °F) with no icing or
condensation
Ambient Temperature
Standards Compliance
Certifications
UL 508, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Operating: 45…85% (no condensation)
Ambient Humidity
Weight
Approx. 50 g
(1) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms
Load Current Versus Ambient Temperature Characteristics
7±±-SC_ _3...
7±±-SC_ _2...
5
4
5
4
3
2
3
2
1
0
1
0
Ambient Temperature [° C]
Ambient Temperature [° C]
230
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
(1)
Inrush Current Resistivity
7±±-SCNN3...
7±±-SCNY3
7±±-SCZ....
7±±-SCT...
7±±-SCNN2...
30
12
10
50
40
30
20
28
26
24
22
20
18
16
14
12
10
8
8
6
4
2
6
4
10
0
2
0
0
Energizing Time [ms]
Energizing Time [ms]
Energizing Time [ms]
(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance
1. AC-switching models comply with EMC Directives under the
following conditions
3 m max.
Load
Input
700-SC Output
Varistor
Film capacitor
Varistor: 470 V, 0.6 W
Film capacitor: 1
µF, 250 VAC
• Connect a varistor between the output terminals.
• Connect a film capacitor to the load power supply.
• The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the
following conditions
Less than 10 m
Load
Input
700-SC
Output
• The input cable must be less than 10 m.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
231
Relay and Timer Specifications
Dimensions - 700-SC Relays
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for
manufacturing purposes.
Terminal Arrangement/
Internal Connections
(Bottom View)
1
5
4
8(+)
(+)
(–)
28 max.
Load
Load
power
supply
Load
Input
9
12(–)
13
–
14
+
36.5 max.
42.5 max.
21.5 max.
+
–
Input voltage
Note: The plus and minus symbols shown
in parentheses are for DC loads.
(1)
Cat. No 700-SC…
(1) 700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket.
Basic Application Considerations for 700-SC
High-density Mounting of Multiple Solid-state Relays (SSRs)
If multiple relays are mounted side by side, the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so
that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Connection
For DC Load Switching, 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.
Protective Component
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in
surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.
Select a varistor that meets the conditions of the load voltage that is outlined in the table below.
Load Voltage [V AC]
100…120
Varistor Voltage [V]
240…270
Varistor Surge Resistance
200…240
440…470
1000 A min.
380…480
820…1000
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
Load
Load power
supply
Input
SSR
232
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-SF Square Base Relays
•
•
•
•
•
•
3 A (resistive) max. continuous load (output) current
264V AC or 52.8V DC max. load voltage options
4…24V DC control/input voltage
Photocoupler or phototriac isolation option between control and output voltage
LED Indicator for input/logic ON/OFF status monitoring
700-HN116 socket compatible
Output (Load)
Max. Continuous Current and
Rated Voltage Range
Input-to-Output Isolation
Method
Rated Input Control
Voltage
Zero Cross Function Status Indicator
Cat. No.
Photocoupler
Phototriac
Yes
5…24V DC
24V DC
700-SFZY3Z25
700-SFTY3Z24
700-SFNY3Z25
3 A @ 100…240V AC
(47...63 Hz)
No
Yes
Photocoupler
Not Applicable
3 A @ 4…48V DC
4…24V DC
Accessories-700-SF Relays
Description
Pkg. Quantity
Cat. No.
Photo
Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays.
10
10
700-HN116
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
199-DR1
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10
easy placement on relays.
700-N40
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
10
700-N41
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in
socket.
10
700-HN114(1)
(1) 700-SF must use Cat. No. 700-HN114 series B retainer clip.
Specifications- 700-FS Relays
Control/Input Ratings
Cat. No.
Rated Control
Voltage
Max. Operating
Control Voltage
Range [V DC]
Max. Reverse
Control Voltage [V]
Impedance
Control Voltage Levels
Pick-up Voltage
Drop-out Voltage
(1)
700-SFZY3Z25
700-SFTY3Z24
5…24V DC
24V DC
4…28V DC
–32
15 mA max.
4V DC max.
1V DC min.
1V DC min.
19.2…28.8V DC
–28.8
2 kΩ 20%
19.2V DC max.
1.5 k
Ω
+ 20%/–
700-SFNY3Z25
5…24V DC
4…28V DC
–28.8
4V DC max.
1V DC min.
10% (2)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
233
Relay and Timer Specifications
Load/Output Ratings
(4)
Cat. No.
Rated Control Voltage
Max. Load Voltage
Range
Continuous Load Current (Resistive) [A]
(3)
Max. Inrush Current
Min.
0.1
Max.
700-SFZY3Z25
700-SFTY3Z24
700-SFNY3Z25
3
3
3
45 A @ 50/60 Hz,
1 cycle
100…240V AC
4…48V DC
75…264V AC
3…52.8V DC
0.1
0.1
18 A (10 ms)
Characteristics
Description
Cat. No. 700-SFZY3Z25
Cat. No. 700-SFTY3Z24
Cat. No. 700-SFNY3Z25
Load Switching Method/Device
Triac
Transistor
1/2cycleofloadpowersource
Pick-up Time
1 ms max.
0.5 ms max.
cycle time (5) +1msmax.
Drop-out Time
Output ON Voltage Drop
1/2 cycle of load power source cycle time (5) + 1 ms max.
1.6V (RMS) max.
2 ms max.
1.5V max.
5 mA max. (@ 100V AC);
10 mA max. (@ 200V AC)
600
2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V
AC)
600
50
250
18
Output Leakage Current
5 mA max. (@ 50V DC)
Output V , V (V)
DRM CEO
80
Output di/dt (A/uS)
Output dv/dt (V/uS)
50
250
18
—
—
—
2
2
Output I t (A S)
Output Tj (°C) Max.
125
125
150
Insulation Resistance
Dielectric Strength
Vibration Resistance (Max.)
Shock Resistance (Max.)
100 MΩ min.(at500VDC)
1,500V AC, 50/60 Hz for 1 min
10…55 Hz, 1.5 mm double amplitude (10 G)
2
1000 m/s (100 G)
Ambient Temperature
Operating: –30…+80 °C (–22…+176 °F) with no icing or condensation Storage: –30…+100 °C (–22…=212 °F) with no icing or condensation
Ambient Humidity
Standards Compliance
Certifications
45…85% (no condensation)
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Approx. 50 g
Weight
(1) With constant current input circuit system, SSR impedance varies with a change in input voltage.
(2) Input impedance reaches its maximum at the operating voltage.
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity”graphs on page 116 for more details.
(4) See “Load Current vs. Ambient Temperature Characteristics”on page 116 for additional load current details.
(5) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms.
IMPORTANT This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is
the ability of an SSR to withstand a large surge current for a short period.
Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
234
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
(1)
(1)
Load Current vs. Ambient
Inrush Current Resistivity
700-SFZ… 700SFT…
Inrush Current Resistivity
700-SFN…
Temperature Characteristics
700-SF
4
30
28
26
50
40
24
22
3
2
20
18
16
14
12
30
20
10
8
6
4
2
1
10
0
0
0
Ambient Temperature [° C]
Energizing Time [ms]
Energizing Time [ms]
(1) Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds).
Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
EMC Directive Compliance
1. AC-switching models comply with EMC Directives under the
following conditions
3 m max.
Load
Input
700-SF
Output
Varistor
Film capacitor
Varistor: 470 V, 0.6 W
Film capacitor: 1
µF, 250 VAC
• Connect a varistor between the output terminals.
• Connect a film capacitor to the load power supply.
• The input cable must be less than 3 m.
2. DC-switching models comply with EMC Directives under the
following conditions
Less than 10 m
Load
Input
700-SF
Output
• The input cable must be less than 10 m.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
235
Relay and Timer Specifications
Dimensions - 700-SF Relays
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for
manufacturing purposes.
Terminal Arrangement/Input Connections
(Bottom View)
1
2
(+)
(-)
4(+)
3
Load
Load
Input
28
max
5
6(-)
7
8
+
-
36.5 max
42.5 max
21.5
max
+
-
Input Voltage
Notes: 1.The plus and minus symbols
shown in parentheses are
for DC loads.
2.The coil has no polarity.
IMPORTANT 700-SF is compatible with Cat. No. 700-HN116 socket.
Basic Application Considerations of 700-SF
High-density Mounting of Multiple Solid-state Relays (SSRs)
If multiple SSRs are mounted side by side, the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so
that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Connection
For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals.
Protective Component to Extend SSR Life
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in
surge suppression (700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.
Select a varistor that meets the conditions of the load voltage that is outlined in the table.
Load Voltage [V AC]
100…120
Varistor Voltage [V]
240…270
Varistor Surge Resistance
200…240
440…470
1000 A min.
380…480
820…1000
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive
force (OFF) of the load.
Load
Load power
supply
Input
SSR
236
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
700-SH Hockey Puck Relays
•
•
•
•
•
100 A max. continuous load (output) current with appropriate heat sink
264V AC, 530V AC, or 660V AC max. load voltage options
3…32V DC, 4…32V DC, 80…130V AC, 200…260V AC, 20…280V AC/22…48V DC control (input) voltage options
LED indicator for input/logic ON/OFF status monitoring
Protective cover for added safety
Input-to-
Output
Isolation
Method
Output (Load) Max.
Continuous Current
and Rated Voltage
Range (1)
Zero Cross
Function
Status
Indicator
Rated Input
Control Voltage
Photo
Cat. No.(2)
10 A @ 42…265V AC
10 A @ 42…265V AC
10 A @ 42…265V AC
10 A @ 42…530V AC
25 A @ 42…530V AC
25 A @ 24…265V AC
3…32V DC
80…130V AC
200…260V AC
4…32V DC
4…32V DC
3…32V DC
700-SH10JZ24
700-SH10JA12
700-SH10JA22
700-SH10HZ25 (Series B)
700-SH25HZ25 (Series B)
700-SH25GZ24
20…280V AC/
22…48V DC
25 A @ 24…265V AC
50 A @ 24…265V AC
50 A @ 24…265V AC
700-SH25GA24
700-SH50GZ24
700-SH50GA24
3…32V DC
20…280V AC/
22…48V DC
50 A @ 42…530V AC
25 A @ 42…660V AC
4…32V DC
4…32V DC
700-SH50HZ25
700-SH25VZ25
20…280V AC/
22…48V DC
25 A @ 42…660V AC
50 A @ 42…660V AC
50 A @ 42…660V AC
700-SH25VA24
700-SH50VZ25
700-SH50VA24
Yes
Yes
4…32V DC
Optocoupler
20…280V AC/
22…48V DC
75 A @ 42…530V AC
75 A @ 42…660V AC
4…32V DC
4…32V DC
700-SH75HZ25
700-SH75VZ25
20…280V AC/
22…48V DC
75 A @ 42…530V AC
700-SH75HA24
20…280V AC/
22…48V DC
75 A @ 42…660V AC
100 A @ 42…530V AC
100 A @ 42…530V AC
100 A @ 42…660V AC
100 A @ 42…660V AC
700-SH75VA24
700-SH100HZ25
700-SH100HA24
700-SH100VZ25
700-SH100VA24
4…32V DC
20…280V AC/
22…48V DC
4…32V DC
20…280V AC/
22…48V DC
Yes
Yes
No
5 A @ 3...60V DC
3…32V DC
700-SH5FZ24
25 A @ 90…280V AC
50 A @ 90…280V AC
4…20 mA DC
4…20 mA DC
700-SH25WA25
700-SH50WA25
Yes
(1) When used with heat sink.
(2) All catalog numbers are Series A unless noted.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
237
Relay and Timer Specifications
Accessories - 700-SH Relays
Photo
Description
Pkg. Quantity
Cat. No.
Heat Sink— Panel or DIN Rail Mount
1
700-SN10
Heat Sink— Panel or DIN Rail Mount
1
700-SN25
Heat Sink— Panel or DIN Rail Mount
1
1
700-SN50
Heat Sink— Panel or DIN Rail Mount
Heat Sink— Panel or DIN Rail Mount
700-SN50HC
1
700-SN50VHC
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Thermal Conductive Pads
50
25
10
700-SHCPAD
700-SHCOV
700-SHTRMA
Plastic Covers — for DC output version
Thermal Adapters - for 100 A Wire
238
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications- 700-SH Relays
Control/Input Ratings
Cat. No.
Operating Voltage
Input Current @ Max.
Voltage
Voltage Level Pickup Voltage
Drop-out Voltage
3…32V DC
80…130V AC
12 mA
13 mA
13 mA
12 mA
20 mA
12 mA
20 mA
12 mA
20 mA
4…20 mA
12 mA
2.75V DC max.
70V AC max.
190V AC max.
4V DC max.
18V AC/DC
2.5V DC
1.2V DC min.
30V AC min. (1)
90V AC min.
1V DC min.
6V AC/DC
1.2V DC
700-SH10J…
200...280V AC
4…32V DC
700-SH_ _ H…
700-SH_ _ G…
700-SH_ _ V…
20…280V AC/22…48V DC
3…32V DC
20…280V AC/22…48V DC
4…32V DC
-32V DC
6V AC/DC
1.2V DC
3.5V DC
20…280V AC/22…48V DC
Current Control
18V AC/DC
—
6V AC/DC
—
700-SH_ _ W…
700-SH_ _ F…
3…32V DC
3V DC max.
1.0V DC
(1) When specified heatsink is used.
Output Ratings
(2)
Cat. No.
700-SH5FZ24
Load Voltage Range
3…60V DC
Applicable Load Current with Heat Sink [A]
0.001…5 A DC
0.15…10
0.15…10
0.15…25
0.15…25
0.15…25
0.15…25
0.15…50
0.15…50
0.15…50
0.15…50
0.15…75
0.15…75
0.15…100
0.15…100
700-SH10J…
42…265V AC
42…530V AC
24…265V AC
42…530V AC
42…660V AC
90…280V AC
24…265V AC
42…530V AC
42…660V AC
90…280V AC
42…530V AC
42…660V AC
42…530V AC
42…660V AC
700-SH10H…
700-SH25G…
700-SH25H…
700-SH25V…
700-SH25W…
700-SH50G…
700-SH50H…
700-SH50V…
700-SH50W…
700-SH75H…
700-SH75V…
700-SH100H…
700-SH100V…
(2) AC unless indicated.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
239
Relay and Timer Specifications
Characteristics
Description
Cat. Nos. 700-SH10, 25, 50
(not including 700-SH_ _W)
Cat. Nos. 700-SH75, 100
Pick-up Time
1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input)
1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input)
1.6V (RMS) max.
Drop-out Time
Output ON Voltage Drop
<3 mA
100MΩ min(@500VDC)
RMS
Output Leakage Current
Insulation Resistance
Dielectric Strength
Vibration Resistance
Shock Resistance
100MΩ min.(at500VDC)
>4000V AC
RMS
Malfunction: 10…55 Hz, 1.5 mm double amplitude
2
Malfunction: 1000 m/s
Operating: –20…+70 °C with no icing or condensation
Storage: –40…+100 °C with no icing or condensation
0…95% no condensing
Ambient Temperature
Ambient Humidity
Standards Compliance
Certifications
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)
Weight
Approx. 60 g
Approx. 100 g
Description
Cat. No. 700-SH_ _W
4.2 mA
Pick-up Current
Drop-out Current
Voltage Drop
4.1 mA
<10V DC @ 20 mA
<3 mA
Leakage Current
Insulation Voltage
Vibration Resistance
Shock Resistance
Ambient Temperature
Ambient Humidity
<4000 V
RMS
Malfunction: 10…55 Hz, 1.5 mm double amplitude
2
Malfunction: 1000 m/s
Operating: –20…+70 °C with no icing or condensation
0…95% no condensing
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2,
EN 61000-6-4
Standards Compliance
Certifications
Weight
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)
Approx. 60 g
Description
Cat. No. 700-SH5FZ24
<3V DC
Pick-up Voltage
Drop-out Voltage
>1V DC
Activating Frequency
Input Impedance
<100 Hz
1kΩ
Response Time Pick-up @ Vin > 5V
Response Time Drop-out
<4000 uS
<1 mS
On-state Voltage Drop @ Rated Current
<1.5V
240
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Description
Off-state Current Drop @ Rated Voltage
Cat. No. 700-SH5FZ24
<1 mA
Insulation Voltage
Vibration Resistance
Shock Resistance
<1 mA
Malfunction: 10…55 Hz, 1.5 mm double amplitude
2
Malfunction: 1,000 m/s
Ambient Temperature
Ambient Humidity
Standards Compliance
Operating: –20…+70 °C with no icing or condensation
0…95% no condensing
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No.
240924)
Certifications
Weight
Approx. 60 g
Surge Current vs. Ambient Temperature Characteristics
Surge current resistivity for 700-SH50....
700A
Surge current resistivity for 700-SH10, 25....
350A
600A
500A
400A
300A
200A
100A
0A
300A
250A
200A
150A
100A
50A
0A
10ms
100ms
1000ms
10000m s
Energizing time (ms)
10ms
100ms
1000ms
10000m s
Energizing time (ms)
Surge current resistivity for 700-SH75....
Surge current resistivity for 700SH100....
1200A
2000A
1800A
1600A
1400A
1200A
1000A
800A
600A
400A
200A
0A
1000A
800A
600A
400A
200A
0A
10ms
100ms
1000ms
10000m s
Energizing time (ms)
10ms
100ms
1000ms
10000m s
Energizing time (ms)
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
241
Relay and Timer Specifications
Load current vs. ambient temperature characteristics for 700-SH10….
Load current vs. ambient temperature characteristics for 700-SH25….
30
25
20
15
10
5
12
10
8
700-SN50VHC
700-SN50HC
700-SN50(V)HC
700-SN10 700-SN25
700-SN10
700-SN25
700-SN50
700-SN50
6
4
No heatsink
No heatsink
2
0
0
-20
-10
0
10
20
30
40
50
60
70
80
-20
-10
0
10
20
30
40
50
60
70
80
Ambient temperature (ºC)
Ambient temperature (ºC)
Load current vs. ambient temperature characteristics for 700-SH75….
Load current vs. ambient temperature characteristics for 700-SH50….
80
70
60
50
40
30
20
10
0
60
50
40
30
20
10
0
700-SN50VHC
700-SN50HC
700-SN50VHC
700-SN50HC
700-SN10
700-SN25
700-SN50
700-
700-SN25
700-SN50
No heatsink
No heatsink
-20
-10
0
10
20
30
40
50
60
70
80
-20
-10
0
10
20
30
40
50
60
70
80
Ambient temperature (ºC)
Ambient temperature (ºC)
Load current vs. ambient temperature characteristics for 700-SH5…..
Load current vs. ambient temperature characteristics for 700-SH100….
6
5
4
3
2
1
0
120
100
80
60
40
20
0
700-SN50(V) HC
700-SN50
700-SN50
700-SN50HC
700-SN50VHC
700-SN10
700-SN25
No heatsink
700-SN10
700-SN25
No heatsink
-10
-20
-10
0
10
20
30
40
50
60
70
80
-20
0
10
20
30
40
50
60
70
80
Ambient temperature (ºC)
Ambient temperature (ºC)
242
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
(1) (2) (3) (4)
Mounting Considerations
All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing
purposes.
45.5
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
(Bottom View)
5.3
Load
2 x M5
Screws
Load
Power
Supply
Load
Two Ø 4.4
or M4 Holes
T1
L1
47.5
A1
A2
Input
2 x M3
Screws
13.0
25
45.5
Cat. No. 700-SH5F…
44.8
Two Ø 4.4
or M4 Holes
12.3
2 X M5
Screws
Operating
Indicator
APPLY
47.5
HEATSINK
COMPOUND
2 X M3
Screws
5.2
5.25
25
45.5
Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100
(1) The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required.
(2) When attaching a heat sink to 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink.
Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01).
(3) Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 N•m (6.9…8.7 lb•in).
(4) Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 N•m (8.67…12.12 lb•in), M5: 1.57…2.35 N•m (13.89…20.8 lb•in).
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
243
Relay and Timer Specifications
7±±-SN1±
7±±-SN25
7±±-SN5±
7±±-SN5±HC
7±±-SN5±VHC
12
67
27,5
28,5
Cat. No.700-SHTRMA
Cat. No. 700-SHCOV
244
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Load Connection
•
•
For an AC load, use a power supply that is rated at 50 Hz. or 60 Hz. The maximum operating frequency is 10 Hz.
The 700-SH has a built-in varistor for surge/inrush protection of AC loads. If additional suppression is required, connect an external
varistor across the load device terminals. Select a varistor, which meets the load voltage condition that is outlined in the table.
Load Voltage [V AC]
100…120
Varistor Voltage [V]
240…270
Varistor Surge Resistance
200…240
440…470
1000 A min.
380…480
820…1000
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
Zero Cross Function
An SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises
when the load is switched and minimizes the influence of an inductive load, (such as, lamp, heater, or motor) on the power supply because
the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit.
Output (load voltage)
ON
Input
OFF
At a low applied voltage (for example, 24V AC) the load current is not fully supplied. When the unit is switched ON, the voltage
required to power the unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage
is, the greater the loss time is. This condition, however, will not create any serious problems.
Loss time
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.
Load
Load power
supply
Input
SSR
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
245
Relay and Timer Specifications
700-SK Slim Line Relays
•
•
•
•
•
High-response speed models
Input sensor module to allow high voltage 100…240V AC or 12…24V DC sensor
Interface to low voltage (logic) device such as a PC output module for typical SSR applications
LED indicator
Input modules and output modules can be used with the 700-HN121 or 700-HN221 sockets
Input/Sensor Module
Logic Level
Input-to-Output Isolation
Method
Rated Input Sensor
Voltage
Status Indicator
Response Frequency
Cat. No.
Supply Voltage Supply Current
10 Hz
1 kHz
100…240V AC (1)
12…24V DC
700-SKICA18
700-SKICZ24
Photocoupler
Yes
4…32V DC
0.1…100 mA
(1) 47…63 Hz
Output/SSR Module
Input-to-Output Isolation Zero Cross
Output (Load) Max. Continuous Current Rated Input Control
Status Indicator
Cat. No.
Method
Function
and Rated Voltage Range
Voltage
Yes
700-SKOZ2Z25
700-SKON2Z25
700-SKOC2Z25
700-SKOC1Z25
(1)
Phototriac
2 A @ 100…240V AC
No
Yes
5…24V DC
2 A @ 5…48V DC
Photocoupler
Not Applicable
1.5 A @ 48…200V DC
(1) 47…63 Hz
Accessories - 700-SK Relays
Photo
Description
Pcs./Pkg.
Cat. No.
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1-
pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip.
10
700-HN121
DIN (#3) symmetrical hat rail
35 x 7.5 x 1 m
10
199-DR1
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of
the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy
placement on relays.
10
10
700-N40
700-N41
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing. Each
sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.
246
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
Specifications - 700-SK Relays
Input Sensor Module
Input Sensor Ratings
Cat. No.
Rated Input Voltage
Max. Operating Input
Voltage Range
Input Current
Pick-up Voltage
Drop-out Voltage
700-SKICZ24
12…24V DC
6.6…32V DC
60…264V AC
8 mA max.
6.6V DC max.
60V AC max.
3.6V DC min.
20V AC min.
700-SKICA18
100…240V AC
15 mA max.
Output Logic Ratings
Cat. No.
Logic Level Supply Voltage
Logic Level Supply Current Draw
700-SKICZ24
700-SKICA18
4…32V DC
0.1…100 mA
Characteristics
Description
Cat. No. 700-SKICA18
20 ms max.
Cat. No. 700-SKICZ24
0.1 ms max.
Pick-up time
Drop-out time
Response frequency
20 ms max.
0.1 ms max.
10 Hz
100 Hz
Output ON voltage drop
1.6V max.
Leakage current (from SSR)
5 μA max.
Output V , V (V)
DRM CEO
80 (ref. value)
80 (ref. value)
Output di/dt (A/uS)
Output dv/dt (V/uS)
—
—
—
150
—
—
—
150
2
2
Output I t (A S)
Output Tj (°C) Max.
Insulation Resistance
Dielectric Strength
100 MΩ min. between input and output
4000V AC, 50/60 Hz for 1 min between input and output
10…55 Hz, 1.5 mm double amplitude (10 G)
1000 m/s2 (100 G)
Vibration Resistance (Max.)
Shock Resistance (Max.)
Operating
–30…+80 °C (–22…+176 °F) with no icing or condensation
–30…+100 °C (–22…+212 °F) with no icing or condensation
UL 508, CSA C22.2 No. 14, EN/IEC 60950
Ambient Temperature
Storage
Standards Compliance
Certifications
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified
45…85% (no condensation)
Ambient humidity Operating
Weight
Approx. 18 g
Output SSR Module
Control/Input Ratings
Cat. No.
(1)
Rated Control
Voltage
Max. Operating
Control Voltage
Range
Max. Reverse
Control Voltage
Impedance
Pick-up Voltage
Drop-out Voltage
700-SKOZ2Z25
700-SKON2Z25
700-SKOC2Z25
700-SKOC1Z25
15 mA max.
at 25 °C (77 °F)
5…24V DC
4…32V DC
-32V DC
4V DC max.
1V DC min.
8 mA max.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
247
Relay and Timer Specifications
Load/Output Ratings
Cat. No.
(3)
Rated Load Voltage
Maximum Load Voltage
Range
Continuous Load Current (Resistive) [A]
(2)
Max. Inrush Current
Min.
Max.
700-SKOZ2Z25
700-SKON2Z25
700-SKOC2Z25
700-SKOC1Z25
30 A (@50/60 Hz,
One cycle)
100…240V AC
75…264V AC
0.05
2
5…48V DC
4…60V DC
0.1
0.1
2
8 A (10 ms)
8 A (10 ms)
48…200V DC
40…200V DC
1.5
(1) With a constant current input system. SSR impedance varies with a change in input voltage.
(2) See "Load Current vs. Ambient Temperature Characteristics" graphs on page 126 for additional details.
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity”graphs on page 126 for more details.
Characteristics
Description
Load Switching Method/Device
Pick-up Time
Cat. No. 700-SKOZ2Z25
Cat. No. 700-SKON2Z25
Cat. No. 700-SKOC2Z25
Cat. No. 700-SKOC1Z25
Triac
Transistor
1/2 cycle of load power source cycle time (1) + 1 ms max.
1 ms max.
2 ms max.
100 Hz
Drop-out Time
1/2 of load power source cycle time (1) + 1 ms max.
Response Frequency
20 Hz
Output ON Voltage Drop
Leakage Current (from SSR)
1.6V max.
1.5 mA max.
2.5V max.
1 mA max.
Output V , V (V)
DRM CEO
600 (ref.value)
600 (ref.value)
80 (ref.value)
400 (ref.value)
Output di/dt (A/uS)
Output dv/dt (V/uS)
30
30
—
—
—
150
—
—
—
150
300
10.4
125
300
10.4
125
2
2
Output I t (A S)
Output Tj (°C) Max.
Insulation Resistance
Dielectric Strength
100 MΩ min. between input and output
4000V AC, 50/60 Hz for 1 min between input and output
10…55 Hz, 1.5 mm double amplitude (10 G)
Vibration Resistance (Max.)
Shock Resistance (Max.)
2
1000 m/s (100 G)
Operating
Storage
–30…+80 °C (–22…+176 °F) with no icing or condensation
–30…+100 °C (–22…+212 °F) with no icing or condensation
UL 508, CSA C22.2 No. 14, EN/IEC 60950
Ambient
Temperature
Standards Compliance
Certifications
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified
Ambient Humidity Operating
Weight
45…85% (no condensation)
Approx. 18 g
(1) 60 Hz cycle time = 16.6 ms, 50 Hz cycle time = 20 ms.
Load Current vs. Ambient Temperature Characteristics
For 2 A Versions
2
2
1.5
1
1.5
1
0.5
0.5
Ambient Temperature [° C]
Ambient Temperature [° C]
248
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Relay and Timer Specifications
(2)
Inrush Current Resistivity
7±±-SKOC2
7±±-SKOZ/SKOC1
7±±-SKOZ/SKON
10
9
8
7
6
5
4
3
2
1
0
10
9
30
8
7
6
5
4
3
2
20
10
1
0
Energizing Time (ms)
Energizing Time (ms)
Energizing Time (ms)
(2) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.
Dimensions - 700-SK Relays
All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not to be used for manufacturing
purposes.
IMPORTANT The input module (700-SKI) and output module (700-SKO) are compatible with the Cat. No. 700-HN121 socket.
Terminal Arrangement/
Internal Connections
1
5.2
(Bottom View)
3
4
9.6
3
(+)
(–)
0.5
29 max.
17.4
4
4.75
Load
1
5
13 max.
28 max.
5
7.5
4.7
0.5
Input
4.75
4
5
1
10
(–)
(+)
2
20
Application Considerations of the700-SK Relay
Connection
For DC load switching, 700-SK SSR will operate properly if the load is connected to either the positive or negative SSR load terminal. The load can
be connected to either positive or negative output terminals of the SSR.
Protective Element (to extend SSR life)
Since the SSR does not incorporate a surge absorption component, be sure to connect a surge absorption component when using the SSR to control
an inductive load.
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
249
Relay and Timer Specifications
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource
Description
General Purpose, Interposing, Solid-State and Specialty Relays Brochure publication
700-BR018
Provides product overview and applications for Bul 700 relay line.
Solid-state Relay Application Guide, publication 700-AT001
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Product Certifications website, rok.auto/certifications.
Provides methods for applying and troubleshooting Solid-state relays.
Provides general guidelines for installing a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at http://www.rockwellautomation.com/global/literature-library/
overview.page.
250
Rockwell Automation Publication 700-TD552D-EN-P - June 2019
Rockwell Automation Support
Use the following resources to access support information.
Knowledgebase Articles, How-to Videos, FAQs, Chat,
User Forums, and Product Notification Updates.
Technical Support Center
www.rockwellautomation.com/knowledgebase
www.rockwellautomation.com/global/support/get-support-
now.page
Local Technical Support Phone Numbers
Locate the phone number for your country.
Find the Direct Dial Code for your product. Use the
code to route your call directly to a technical support
engineer.
www.rockwellautomation.com/global/support/direct-
dial.page
Direct Dial Codes
Literature Library
Installation Instructions, Manuals, Brochures, and
Technical Data.
www.rockwellautomation.com/literature
Get help determining how products interact, check
features and capabilities, and find associated
firmware.
Product Compatibility and Download Center
(PCDC)
www.rockwellautomation.com/global/support/pcdc.page
Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 700-TD552D-EN-P - June 2019
Supersedes Publication 700-TD552C-EN-P - October 2018
Copyright © 2019 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
相关型号:
700-FSM4UZ12
Multi-Delay Relay, DPDT, Momentary, 12VDC (Coil), 0.05s Adj Min, 216000s Adj Max, AC Output, DIN-Rail Mount,
ROCKWELL
©2020 ICPDF网 联系我们和版权申明