03S12S-000S3 [ROSENBERGER]

RPC-3.50 Calibration Kit;
03S12S-000S3
型号: 03S12S-000S3
厂家: Rosenberger Hochfrequenztechnik GmbH & Co. KG    Rosenberger Hochfrequenztechnik GmbH & Co. KG
描述:

RPC-3.50 Calibration Kit

PC 连接器
文件: 总3页 (文件大小:142K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical Data Sheet  
Calibration Kit  
RPC-3.50  
03CK001-150  
Full Version  
Contents  
Device  
Part number  
Quantity  
Calibration Optiona  
Open circuit plug  
03S12L-000S3  
03K12L-000S3  
03S12S-000S3  
03K12S-000S3  
03S150-C10S3  
03K150-C10S3  
03S121-S20S3  
03K121-K20S3  
03W008-000  
1
1
1
1
1
1
1
1
1
1
FC / AC  
FC / AC  
FC / AC  
FC / AC  
FC / AC  
FC / AC  
FC / AC  
FC / AC  
-
Open circuit jack  
Short circuit plug  
Short circuit jack  
Calibration load plug  
Calibration load jack  
Calibration adaptor plug/plug  
Calibration adaptor jack/jack  
Combi wrench  
Torque wrench  
03W021-000  
FC  
Gauge jack  
03W00S-000  
03W00K-000  
1
1
FC  
FC  
(including gauge block)  
Gauge plug  
(including gauge block)  
a.  
See “Declaration of calibration options” for explanation.  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
1 / 3  
Technical Data Sheet  
Calibration Kit  
RPC-3.50  
03CK001-150  
Full Version  
Documentation  
This kit is delivered with  
USB-Stick  
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA  
(Rohde&Schwarz). Calibration Certificate as PDF-file.  
Standard Definitions Cards  
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.  
Kit Info Card  
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.  
Calibration Certificate  
Details see “Declaration of calibration options”  
Operating Manual  
Electrical specifications  
This specification covers electrical key values for the main calibration standards of the calibration kit.  
Specific datasheets are available for each component among the part number.  
Calibration standard  
Frequency  
Parameter  
Specification  
4 GHz  
to  
1.0  
1.5  
2.0  
DC  
Opensb  
(plug and jack)  
Error from  
Nominal Phase  
> 4 GHz to  
> 8 GHz to  
8 GHz  
26.5 GHz  
4 GHz  
to  
1.0  
1.5  
2.0  
DC  
Shortsb  
(plug and jack)  
Error from  
Nominal Phase  
> 4 GHz to  
> 8 GHz to  
8 GHz  
26.5 GHz  
4 GHz  
to  
40 dB  
35 dB  
30 dB  
DC  
Calibration loads  
> 4 GHz to  
> 8 GHz to  
Return Loss  
Return Loss  
8 GHz  
26.5 GHz  
(plug and jack)  
4 GHz  
to  
34 dB  
32 dB  
30 dB  
DC  
Calibration adaptors  
(plug/plug and jack/jack)  
> 4 GHz to  
> 8 GHz to  
8 GHz  
26.5 GHz  
b.  
The specifications for opens and shorts are given as allowed deviation from nominal model as defined in calibration certificate  
included with your kit.  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
2 / 3  
Technical Data Sheet  
Calibration Kit  
RPC-3.50  
03CK001-150  
Full Version  
Declaration of calibration options  
Factory Calibration  
Standard delivery for this kit includes a Factory Calibration. All devices marked with “FC” in the Content table  
above are reported in a Calibration Certificate with their individual calibration results, traceable to national /  
international standards. Classical standard definitions of the calibration standards are reported in Agilent,  
Rohde&Schwarz and Anritsu compatible VNA format.  
Accredited Calibration  
Optional this kit can be delivered with an Accredited Calibration (DAkkS) having the highest confidence in the  
traceability. All devices marked with “AC” in the Content table above are reported in a DAkkS Calibration  
Certificate with their individual calibration results in a complex format, traceable to national / international  
standards. Classical standard definitions of the calibration standards are reported in Agilent, Rohde&Schwarz  
and Anritsu VNA format as well as in dense data sets needed for databased calibration kits. The uncertainties  
are a little bit smaller than in a Factory Calibration.  
All devices marked with “FC” only cannot be calibrated under accreditation. They are factory calibrated as  
described above.  
For further, more detailed information see application note AN001 on the Rosenberger homepage.  
Calibration interval  
Recommendation  
12 months  
Recommended accessories  
- Rosenberger Test Port Adaptor  
- Rosenberger VNA Test cable kit and Microwave Cable Assemblies  
For further, more detailed information please visit our homepage www.rosenberger.com.  
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on  
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our  
products, we reserve the right to make changes judged to be necessary.  
Draft  
Date  
Approved  
Date  
Rev.  
a00  
Engineering change number  
14-s366  
Name  
Date  
Martin Moder  
23.10.14  
R. Neuhauser  
28.10.14  
S. Andorfer  
28.10.14  
Rosenberger Hochfrequenztechnik GmbH & Co. KG  
P.O.Box 1260 D-84526 Tittmoning Germany  
www.rosenberger.de  
Tel. : +49 8684 18-0  
Fax : +49 8684 18-499  
Email : info@rosenberger.de  
Page  
3 / 3  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY