FMET-21510 [SANKEN]

Rectifier Diode, Schottky, 1 Phase, 2 Element, 7.5A, 100V V(RRM), Silicon, TO-220AB, TO-220F, 3 PIN;
FMET-21510
型号: FMET-21510
厂家: SANKEN ELECTRIC    SANKEN ELECTRIC
描述:

Rectifier Diode, Schottky, 1 Phase, 2 Element, 7.5A, 100V V(RRM), Silicon, TO-220AB, TO-220F, 3 PIN

局域网 功效 二极管
文件: 总6页 (文件大小:344K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VRSM = 100 V, IF(AV) = 15 A  
Trench Schottky Diode  
Preliminary  
FMET-21510  
Features  
Package  
FMET-21510 is 100 V / 15 A Schottky Diode of the  
Trench structure and has the improved characteristics of  
VF and IR. These characteristics realize the improving of  
power supply efficiency, and the high frequency system.  
TO220F-3L  
VRM------------------------------------------------------ 100 V  
IF(AV)--------------------------------------------------------15A  
VF (125 °C, IF = 3.5 A)------------------------- 0.57 V typ.  
Applications  
(1) Anode  
(2) Cathode  
(3) Anode  
The high speed switching applications as follows:  
DC-DC Converter  
Adapter  
(1)(2)(3)  
(1)  
(3)  
(2)  
Not to scale  
Absolute Maximum Ratings  
Unless otherwise specified, Tj is 25 °C  
Notes  
Parameter  
Symbol  
VRSM  
VRM  
Rating  
100  
Unit  
V
Peak Repetitive Reverse Voltage  
Repetitive Reverse Voltage  
Average Forward Current  
100  
V
IF(AV)  
15  
A
10 ms  
Half sinewave, one shot  
Surge Forward Current  
IFSM  
100  
A
Junction Temperature  
Storage Temperature  
Tj  
40 to 150  
40 to 150  
°C  
°C  
Tstg  
Electrical Characteristics  
Unless otherwise specified, Tj is 25 °C  
Parameter  
Symbol  
Test Conditions  
IF = 3.5 A  
IF = 7.5 A  
Min.  
Typ.  
Max.  
Unit  
V
0.65  
0.81  
0.57  
0.67  
0.3  
Forward Voltage Drop  
VF  
0.85  
V
Tj = 125 °C, IF = 3.5 A  
Tj = 125 °C, IF = 7.5 A  
VR = VRM  
V
Forward Voltage Drop  
Under High Temperature  
HVF  
V
Reverse Leakage Current  
IR  
50  
µA  
Reverse Leakage Current  
Under High Temperature  
VR = VRM, Tj = 150 °C  
3.0  
25  
mA  
HIR  
Rth(j-c)  
Thermal Resistance*  
4.0  
°C/W  
* Rth(j-c) is thermal resistance between junction and case. Case temperature (TC) is measured at the under of the screw  
hole of case.  
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
http://www.sanken-ele.co.jp/en  
1
 
 
 
 
Preliminary  
FMET-21510  
Performance Curves  
100  
10  
TJ = 150°C  
TJ = 125°C  
TJ = 100°C  
1
TJ = 25°C  
0.1  
0
0.2  
0.4  
0.6  
0.8  
1
1.2  
Forward Voltage Drop, VF (V)  
Figure 1 Typical Forward Characteristics  
1.0E-02  
1.0E-03  
1.0E-04  
1.0E-05  
1.0E-06  
TJ = 150°C  
TJ = 125°C  
TJ = 100°C  
TJ = 25°C  
1.0E-07  
0
20  
40  
60  
80  
100  
Reverse Volatage, VR (V)  
Figure 2 Typical Reverse Leakage Current Characteristics  
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
2
Preliminary  
FMET-21510  
Power Dissipation Curves  
20  
Tj = 150 °C  
t/T=1/6  
t
T
15  
t/T=1/3,sinewave  
t/T=1/2  
10  
5
DC  
0
0
3
6
9
12  
15  
Average Forward Current, IF(AV) (A)  
Figure 3 Forward Power Dissipation, PF vs. Average Forward Current, IF(AV)  
5
4
3
2
1
0
Tj = 150 °C  
1-t/T=5/6  
t
T
1-t/T=2/3  
1-t/T=1/2  
sinewave  
0
20  
40  
60  
80  
100  
Reverse Voltage , VR (V)  
Figure 4 Reverse Power Dissipation, PR vs. Reverse Voltage , VR  
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
3
Preliminary  
FMET-21510  
Derating Curves  
VR = 0 (V)  
15  
12  
9
t/T=1/2  
DC  
t/T=1/6  
r/T=1/3 sinewave  
6
Tj = 150 °C  
3
t
T
0
50  
100  
150  
Case Temperature (°C)  
Figure 5 Average Rectified Forward Current, IF(AV) vs. Case Temperature  
VR = 100 (V)  
15  
12  
9
sinewave  
DC  
t/T=1/6  
t/T=1/3  
6
Tj = 150 °C  
t/T=1/2  
3
t
T
0
50  
100  
Case Temperature (°C)  
Figure 6 Average Rectified Forward Current, IF(AV) vs. Case Temperature  
150  
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
4
Preliminary  
FMET-21510  
Package Outline  
TO220F-3L  
NOTES:  
1) Dimension is in millimeters.  
2) Pin treatment Pb-free. Device composition compliant with the RoHS directive.  
Marking Diagram  
ET1510  
Y M D D  
Part Number  
Lot Number:  
Y is the last digit of the year of manufacture (0 to 9)  
M is the month of the year (1 to 9, O, N or D)  
DD is the day of the month (01 to 31)  
1
2
3
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
5
Preliminary  
FMET-21510  
IMPORTANT NOTES  
All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the  
Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change  
without notice due to improvement of the Sanken Products, etc. Please make sure to confirm with a Sanken sales representative  
that the contents set forth in this document reflect the latest revisions before use.  
The Sanken Products are intended for use as components of general purpose electronic equipment or apparatus (such as home  
appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products,  
please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to  
Sanken. When considering use of the Sanken Products for any applications that require higher reliability (such as transportation  
equipment and its control systems, traffic signal control systems or equipment, disaster/crime alarm systems, various safety  
devices, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix  
your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the  
Sanken Products. The Sanken Products are not intended for use in any applications that require extremely high reliability such as:  
aerospace equipment; nuclear power control systems; and medical equipment or systems, whose failure or malfunction may result  
in death or serious injury to people, i.e., medical devices in Class III or a higher class as defined by relevant laws of Japan  
(collectively, the “Specific Applications”). Sanken assumes no liability or responsibility whatsoever for any and all damages and  
losses that may be suffered by you, users or any third party, resulting from the use of the Sanken Products in the Specific  
Applications or in manner not in compliance with the instructions set forth herein.  
In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically,  
chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such  
uses in advance and proceed therewith at your own responsibility.  
Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the  
occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility,  
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which  
the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human  
injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer  
to the relevant specification documents and Sankens official website in relation to derating.  
No anti-radioactive ray design has been adopted for the Sanken Products.  
No contents in this document can be transcribed or copied without Sanken’s prior written consent.  
The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples, all  
information and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of  
use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be  
suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property  
rights and any other rights of you, users or any third party, resulting from the foregoing.  
● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference  
of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property  
rights or any other rights of Sanken.  
Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,  
including, without limitation, any warranty (i) as to the quality or performance of the Sanken Products (such as implied warranty  
of merchantability, or implied warranty of fitness for a particular purpose or special environment), (ii) that any Sanken Product is  
delivered free of claims of third parties by way of infringement or the like, (iii) that may arise from course of performance, course  
of dealing or usage of trade, and (iv) as to any information contained in this document (including its accuracy, usefulness, or  
reliability).  
In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and  
regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS  
Directive, so as to be in strict compliance with such applicable laws and regulations.  
You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including  
but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical  
Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each  
country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan,  
and follow the procedures required by such applicable laws and regulations.  
Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including  
the falling thereof, out of Sanken’s distribution network.  
Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is  
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting  
from any possible errors or omissions in connection with the contents included herein.  
Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer  
to our official website in relation to general instructions and directions for using the Sanken Products.  
DSGN-CEZ-16001  
FMET-21510-DSE Rev.0.2  
Apr. 12, 2016  
SANKEN ELECTRIC CO.,LTD.  
6

相关型号:

FMET-21515

Rectifier Diode, Schottky, 1 Phase, 15A, 150V V(RRM), Silicon, TO-220AB, TO-220F, 3 PIN
SANKEN

FMET-23010

Rectifier Diode, Schottky, 1 Phase, 2 Element, 15A, 100V V(RRM), Silicon, TO-220AB, TO-220F, 3 PIN
SANKEN

FMEX2001

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2002

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2004

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2006

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2010

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2016

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2025

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2040

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2060

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC

FMEX2100

Stainless Steel Pressure Gauge (50mm, 63mm, 100mm, 150mm)
TTELEC