LC1D115G6 [SCHNEIDER]
TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 115 A - 120 V AC 60 Hz coil;型号: | LC1D115G6 |
厂家: | SCHNEIDER ELECTRIC |
描述: | TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 115 A - 120 V AC 60 Hz coil |
文件: | 总4页 (文件大小:127K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product data sheet
LC1D115G6
Characteristics
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V
115 A - 120 V AC 60 Hz coil
Product availability : Stock - Normally stocked in distribution facility
Price* : 479.00 USD
Main
Range
TeSys
Product name
TeSys D
Contactor
LC1D
Product or component type
Device short name
Contactor application
Motor control
Resistive load
Utilisation category
AC-3
AC-4
AC-1
Poles description
3P
Power pole contact composition
[Ue] rated operational voltage
3 NO
Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current
Motor power kW
200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
115 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
30 kW 220...230 V AC 50/60 Hz AC-3)
55 kW 380...400 V AC 50/60 Hz AC-3)
59 kW 415...440 V AC 50/60 Hz AC-3)
75 kW 500 V AC 50/60 Hz AC-3)
80 kW 660...690 V AC 50/60 Hz AC-3)
65 kW 1000 V AC 50/60 Hz AC-3)
18.5 kW 400 V AC 50/60 Hz AC-4)
Motor power HP (UL / CSA)
30 hp 200/208 V AC 50/60 Hz 3 phase
40 hp 230/240 V AC 50/60 Hz 3 phase
75 hp 460/480 V AC 50/60 Hz 3 phase
100 hp 575/600 V AC 50/60 Hz 3 phase
Control circuit type
AC at 60 Hz
[Uc] control circuit voltage
Auxiliary contact composition
120 V AC 60 Hz
1 NO + 1 NC
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Jan 4, 2021
1
[Uimp] rated impulse withstand voltage
Overvoltage category
8 kV IEC 60947
III
[Ith] conventional free air thermal
current
200 A 140 °F (60 °C) power circuit
Irms rated making capacity
1260 A 440 V power circuit IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
1100 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
250 A 104 °F (40 °C) - 10 min power circuit
550 A 104 °F (40 °C) - 1 min power circuit
950 A 104 °F (40 °C) - 10 s power circuit
1100 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating
250 A gG <= 690 V type 1 power circuit
200 A gG <= 690 V type 2 power circuit
10 A gG signalling circuit
Average impedance
0.6 mOhm - Ith 200 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Electrical durability
0.8 Mcycles 200 A AC-1 <= 440 V
0.95 Mcycles 115 A AC-3 <= 440 V
Power dissipation per pole
24 W AC-1
7.9 W AC-3
Front cover
With
Mounting support
Plate
Rail
Standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certifications
UL
CSA
GOST
BV
GL
LROS (Lloyds register of shipping)
RINA
DNV
CCC
Connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible without cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible without cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible with cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible with cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)solid without cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)solid without cable end
Tightening torque
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)
Operating time
6...20 ms opening
20...50 ms closing
Safety reliability level
Mechanical durability
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
8 Mcycles
2
Maximum operating rate
2400 cyc/h 140 °F (60 °C)
Complementary
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz
0.3...0.6 Uc (-40…70 °C):drop-out AC 60 Hz
1...1.1 Uc (55…70 °C):operational AC 60 Hz
Inrush power in VA
300 VA 60 Hz 0.8 68 °F (20 °C))
22 VA 60 Hz cos phi 0.3 (at 20 °C)
3…8 W 60 Hz
Hold-in power consumption in VA
Heat dissipation
Auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching current
Minimum switching voltage
Non-overlap time
25...400 Hz
5 mA for signalling circuit
17 V for signalling circuit
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance
Contact compatibility
Compatibility code
> 10 MOhm for signalling circuit
M13
LC1D
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
3
Pollution degree
Ambient air temperature for operation
-40…60 °C
60…70 °C with derating
Ambient air temperature for storage
Operating altitude
-76…176 °F (-60…80 °C)
0...3000 m
Fire resistance
850 °C conforming to IEC 60695-2-1
V1 conforming to UL 94
Flame retardance
Mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open6 Gn for 11 ms
Height
6.22 in (158 mm)
4.72 in (120 mm)
5.35 in (136 mm)
5.51 lb(US) (2.5 kg)
Width
Depth
Net Weight
Ordering and shipping details
Category
22359 - CTR,TESYS D,OPEN,80-150A AC&DC
Discount Schedule
GTIN
I12
00785901235101
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
1
5.35 lb(US) (2.43 kg)
Yes
CZ
Country of origin
Packing Units
Unit Type of Package 1
Package 1 Height
Package 1 width
PCE
7.48 in (19 cm)
6.89 in (17.5 cm)
8.27 in (21 cm)
Package 1 Length
3
Offer Sustainability
Sustainable offer status
California proposition 65
Green Premium product
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony
trioxide, which is known to the State of California to cause cancer. For more information go to
www.P65Warnings.ca.gov
REACh Regulation
EU RoHS Directive
REACh Declaration
Compliant
EU RoHS Declaration
Mercury free
Yes
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure
Circularity Profile
WEEE
Product Environmental Profile
End of Life Information
The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins.
PVC free
Yes
Contractual warranty
Warranty
18 months
4
相关型号: