LC1D38P7 [SCHNEIDER]

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 38 A - 230 V AC 50/60 Hz coil;
LC1D38P7
型号: LC1D38P7
厂家: SCHNEIDER ELECTRIC    SCHNEIDER ELECTRIC
描述:

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 38 A - 230 V AC 50/60 Hz coil

文件: 总4页 (文件大小:146K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Product data sheet  
LC1D38B7  
Characteristics  
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V  
38 A - 24 V AC 50/60 Hz coil  
Product availability : Stock - Normally stocked in distribution facility  
Price* : 193.00 USD  
Main  
Range  
TeSys  
Product name  
TeSys D  
Contactor  
LC1D  
Product or component type  
Device short name  
Contactor application  
Resistive load  
Motor control  
Utilisation category  
AC-3  
AC-4  
AC-1  
Poles description  
3P  
Power pole contact composition  
[Ue] rated operational voltage  
3 NO  
Power circuit: <= 690 V AC 25...400 Hz  
Power circuit: <= 300 V DC  
[Ie] rated operational current  
Motor power kW  
50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit  
38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit  
18.5 kW at 500 V AC 50/60 Hz (AC-3)  
18.5 kW at 660...690 V AC 50/60 Hz (AC-3)  
7.5 kW at 400 V AC 50/60 Hz (AC-4)  
18.5 kW at 380...400 V AC 50/60 Hz (AC-3)  
9 kW at 220...230 V AC 50/60 Hz (AC-3)  
18.5 kW at 415...440 V AC 50/60 Hz (AC-3)  
Motor power HP (UL / CSA)  
10 hp at 230/240 V AC 50/60 Hz for 3 phases motors  
10 hp at 200/208 V AC 50/60 Hz for 3 phases motors  
5 hp at 240 V AC 50/60 Hz for 1 phase motors  
20 hp at 480 V AC 50/60 Hz for 3 phases motors  
25 hp at 600 V AC 50/60 Hz for 3 phases motors  
Control circuit type  
AC at 50/60 Hz  
24 V AC 50/60 Hz  
1 NO + 1 NC  
[Uc] control circuit voltage  
Auxiliary contact composition  
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.  
Jan 4, 2021  
1
[Uimp] rated impulse withstand voltage  
Overvoltage category  
6 kV conforming to IEC 60947  
III  
[Ith] conventional free air thermal  
current  
10 A (at 60 °C) for signalling circuit  
50 A 140 °F (60 °C) power circuit  
Irms rated making capacity  
140 A AC for signalling circuit conforming to IEC 60947-5-1  
250 A DC for signalling circuit conforming to IEC 60947-5-1  
550 A 440 V power circuit IEC 60947  
Rated breaking capacity  
550 A 440 V power circuit IEC 60947  
[Icw] rated short-time withstand current  
60 A 104 °F (40 °C) - 10 min power circuit  
430 A 104 °F (40 °C) - 1 s power circuit  
150 A 104 °F (40 °C) - 1 min power circuit  
310 A 104 °F (40 °C) - 10 s power circuit  
100 A - 1 s for signalling circuit  
120 A - 500 ms for signalling circuit  
140 A - 100 ms for signalling circuit  
Associated fuse rating  
10 A gG for signalling circuit conforming to IEC 60947-5-1  
63 A gG <= 690 V type 1 power circuit  
63 A gG <= 690 V type 2 power circuit  
Average impedance  
2 mOhm - Ith 50 A 50 Hz power circuit  
[Ui] rated insulation voltage  
Power circuit 600 V CSA  
Power circuit 600 V UL  
Signalling circuit: 690 V conforming to IEC 60947-1  
Signalling circuit 600 V CSA  
Signalling circuit 600 V UL  
Power circuit: 690 V conforming to IEC 60947-4-1  
Electrical durability  
1.4 Mcycles 50 A AC-1 at Ue <= 440 V  
1.4 Mcycles 38 A AC-3 at Ue <= 440 V  
Power dissipation per pole  
5 W AC-1  
3 W AC-3  
Front cover  
With  
Mounting support  
Rail  
Plate  
Standards  
CSA C22.2 No 14  
EN 60947-4-1  
EN 60947-5-1  
IEC 60947-4-1  
IEC 60947-5-1  
UL 508  
Product certifications  
CSA  
LROS (Lloyds register of shipping)  
BV  
RINA  
UL  
GOST  
DNV  
CCC  
GL  
Connections - terminals  
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end  
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end  
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end  
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end  
Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end  
Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end  
Power circuit screw clamp terminals 1 0.00…0.02 in² (2.5…10 mm²)flexible without cable end  
Power circuit screw clamp terminals 2 0.00…0.02 in² (2.5…10 mm²)flexible without cable end  
Power circuit screw clamp terminals 1 0.00…0.02 in² (1…10 mm²)flexible with cable end  
Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible with cable end  
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm²solid without cable end  
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm²solid without cable end  
Tightening torque  
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm  
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2  
Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm  
Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2  
Operating time  
4...19 ms opening  
12...22 ms closing  
Safety reliability level  
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1  
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1  
2
Mechanical durability  
15 Mcycles  
Maximum operating rate  
3600 cyc/h 60 °C  
Complementary  
Coil technology  
Without built-in suppressor module  
Control circuit voltage limits  
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz  
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz  
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz  
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz  
Inrush power in VA  
70 VA 60 Hz cos phi 0.75 (at 20 °C)  
70 VA 50 Hz cos phi 0.75 (at 20 °C)  
Hold-in power consumption in VA  
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)  
7 VA 50 Hz cos phi 0.3 (at 20 °C)  
Heat dissipation  
2…3 W at 50/60 Hz  
Auxiliary contacts type  
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1  
type mirror contact 1 NC conforming to IEC 60947-4-1  
Signalling circuit frequency  
Minimum switching current  
Minimum switching voltage  
Non-overlap time  
25...400 Hz  
5 mA for signalling circuit  
17 V for signalling circuit  
1.5 ms on de-energisation between NC and NO contact  
1.5 ms on energisation between NC and NO contact  
Insulation resistance  
Contact compatibility  
Compatibility code  
Motor power range  
> 10 MOhm for signalling circuit  
M2  
LC1D  
7…11 kW at 200…240 V 3 phases  
15…25 kW at 380…440 V 3 phases  
15…25 kW at 480…500 V 3 phases  
15…25 kW at 525…690 V 3 phases  
4…6 kW at 100…120 V 3 phases  
Motor starter type  
Direct on-line contactor  
Environment  
IP degree of protection  
IP20 front face conforming to IEC 60529  
Protective treatment  
TH conforming to IEC 60068-2-30  
3
Pollution degree  
Ambient air temperature for operation  
-40…60 °C  
60…70 °C with derating  
Ambient air temperature for storage  
Operating altitude  
-76…176 °F (-60…80 °C)  
0...3000 m  
Fire resistance  
850 °C conforming to IEC 60695-2-1  
V1 conforming to UL 94  
Flame retardance  
Mechanical robustness  
Vibrations contactor open: 2 Gn, 5...300 Hz  
Vibrations contactor closed: 4 Gn, 5...300 Hz  
Shocks contactor closed: 15 Gn for 11 ms  
Shocks contactor open8 Gn for 11 ms  
Height  
3.35 in (85 mm)  
1.77 in (45 mm)  
3.62 in (92 mm)  
0.84 lb(US) (0.38 kg)  
Width  
Depth  
Net Weight  
Ordering and shipping details  
Category  
22354 - CTR,TESYS D,OPEN,9-38A AC  
Discount Schedule  
GTIN  
I12  
00785901755470  
1
Nbr. of units in pkg.  
Package weight(Lbs)  
0.92 lb(US) (0.42 kg)  
3
Returnability  
Yes  
ID  
Country of origin  
Packing Units  
Unit Type of Package 1  
PCE  
Package 1 Height  
1.97 in (5 cm)  
3.62 in (9.2 cm)  
4.41 in (11.2 cm)  
S02  
Package 1 width  
Package 1 Length  
Unit Type of Package 2  
Number of Units in Package 2  
Package 2 Weight  
Package 2 Height  
20  
19.19 lb(US) (8.705 kg)  
5.91 in (15 cm)  
11.81 in (30 cm)  
15.75 in (40 cm)  
P06  
Package 2 width  
Package 2 Length  
Unit Type of Package 3  
Number of Units in Package 3  
Package 3 Weight  
Package 3 Height  
320  
331.80 lb(US) (150.5 kg)  
31.50 in (80 cm)  
31.50 in (80 cm)  
23.62 in (60 cm)  
Package 3 width  
Package 3 Length  
Offer Sustainability  
Sustainable offer status  
California proposition 65  
Green Premium product  
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony  
trioxide, which is known to the State of California to cause cancer. For more information go to  
www.P65Warnings.ca.gov  
REACh Regulation  
REACh free of SVHC  
EU RoHS Directive  
REACh Declaration  
Yes  
Compliant  
EU RoHS Declaration  
Toxic heavy metal free  
Mercury free  
Yes  
Yes  
Yes  
RoHS exemption information  
China RoHS Regulation  
China RoHS declaration  
Pro-active China RoHS declaration (out of China RoHS legal scope)  
Environmental Disclosure  
Circularity Profile  
WEEE  
Product Environmental Profile  
End of Life Information  
The product must be disposed on European Union markets following specific waste collection and  
never end up in rubbish bins.  
PVC free  
Yes  
Contractual warranty  
Warranty  
18 months  
4

相关型号:

LC1D38U7

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 38 A - 240 V AC 50/60 Hz coil
SCHNEIDER

LC1D50A6L7

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 50 A - 200 V AC 50/60 Hz coil
SCHNEIDER

LC1D50A6P7

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 50 A - 230 V AC 50/60 Hz coil
SCHNEIDER

LC1D50A6R7

TeSys D contactor - 3P(3 NO) - AC-3 - 440 V 50 A - 440 V AC 50/60 Hz coil
SCHNEIDER

LC1D80004N5

TeSys D contactor - 4P(4 NO) - AC-1 - 440 V 125 A - 415 V AC 50 Hz coil
SCHNEIDER

LC1D80004U5

TeSys D contactor - 4P(4 NO) - AC-1 - 440 V 125 A - 240 V AC 50 Hz coil
SCHNEIDER

LC1D80008G6

TeSys D contactor - 4P(2 NO 2 NC) - AC-1 440 V 125 A - 120 V AC 60 Hz coil
SCHNEIDER

LC1DT20

AC/DC
SCHNEIDER

LC1DT25

AC/DC
SCHNEIDER

LC1DT32

AC/DC
SCHNEIDER

LC1DT40

AC/DC
SCHNEIDER

LC1F1154

TeSys™ IEC-Style Contactors and Starters
ETC