6051.2037_18 [SCHURTER]

IEC Interconnection Cord with IEC Connector C13, V-Lock, straight;
6051.2037_18
型号: 6051.2037_18
厂家: SCHURTER INC.    SCHURTER INC.
描述:

IEC Interconnection Cord with IEC Connector C13, V-Lock, straight

文件: 总3页 (文件大小:245K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Cord Sets  
6051.2037  
https://www.schurter.com /PG07  
IEC Interconnection Cord with IEC Connector C13, V-Lock, straight  
C13  
E
See below:  
Approvals and Compliances  
70° C  
70° C  
Description  
- Interconnection Cord ,  
References  
We recommend for new applications the type 3-100-354  
- Protection class I , Pin temperature 70 °C ,  
- with V-Lock interlocking system  
Technical Data  
Ratings IEC  
10A / 250VAC; 50Hz  
appliance inlet/-outlet  
C13 acc. to 60320-2-2  
(for cold conditions) pin-temperature 70  
°C, 10A, Protection Class I  
Dielectric Strength  
> 2kVDC between L-N  
> 2kVAC between L/N-PE  
(1min/50Hz)  
Allowable Operation Tempe-  
rature  
-25°C to 70°C  
IP-Protection  
Insulation cover  
from front side IP 20 acc. to IEC 60529  
Suitable for appliances with protection  
class I acc. to IEC 61140  
moulded  
Terminal  
Material: Housing  
PVC, black  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
Approvals  
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.  
Approval Reference Type: 6051.2037  
Approval Logo  
Certificates  
Certification Body  
Description  
KEMA Approvals  
KEMA  
Keuring van Elektrotechnische Materialien  
Product standards  
Product standards that are referenced  
Organization  
Design  
Standard  
Description  
Designed according to  
IEC 60320-1  
Appliance couplers for household and similar general purposes  
Designed according to  
60320-2-2  
Appliance couplers for household and similar general purposes  
Application standards  
Application standards where the product can be used  
Organization  
Design  
Standard  
Description  
Designed for applications acc.  
IEC/UL 60950  
IEC 60950-1 includes the basic requirements for the safety of information  
technologyequipment.  
1
Connectors  
Cord Sets  
6051.2037  
https://www.schurter.com /PG07  
Compliances  
The product complies with following Guide Lines  
Identification  
Details  
Initiator  
Description  
CE declaration of conformity  
SCHURTER AG  
The CE marking declares that the product complies with the applicable  
requirements laid down in the harmonisation of Community legislation on  
its affixing in accordance with EU Regulation 765/2008.  
RoHS  
SCHURTER AG  
SCHURTER AG  
SCHURTER AG  
EU Directive RoHS 2011/65/EU  
China RoHS  
REACH  
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March  
2007. It is similar to the EU directive RoHS.  
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,  
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as  
"REACH") entered into force.  
MicrositeV-Lock  
SCHURTER AG  
V-Lock system are based on a matching plug-dose combination. The  
connector is equipped with a notch intended for use with the latching  
cordset. The cord latching system prevents against accidental removal of  
the cordset.  
All Variants  
Connector  
cable  
Plug  
Type  
Order Number  
Type  
V-Lock  
Cord Type  
Conductor cross  
section  
Length [m]  
Color  
Country Standard  
Style  
C13  
l
H05VV-  
F3G0.75  
3 x 0.75 mm²  
0.6  
black  
Interconnec- INT  
tion  
IEC 60320-1  
straight  
-
6051.2037  
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER  
150 Pcs  
Packaging unit  
Mating Outlets/Connectors  
Category / Description  
Appliance Outlet Overview complete  
IEC Appliance Outlet F, Snap-in Mounting, Front Side, IDC Terminal, integrated Light Pipe, Color Coding  
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal  
IEC Appliance Outlet F, Integrated Light Pipes, PCB terminals, Color Coding  
6610-5  
6600-3  
6600-5  
6602-4, Mounting: Snap-in version, Appliance Outlet: IEC H, Solder terminals or quick connect terminals, 10 A, Suita-  
ble for appliances with protection class II  
6602-4  
IEC Appliance Outlet F, Snap-in Mounting, Front Side, IDC Terminal  
Appliance Outlet further types to 6051.2037  
6610  
...  
Mating Inlets/Plugs shuttered  
Appliance Inlet Overview complete  
6010, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C14  
6015, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C18  
6048, Mounting: Screw, Appliance Inlet: IEC C14  
6010  
6015  
6048  
6061  
6061, Mounting: Screw, Appliance Inlet: IEC C14  
GSP1, Mounting: Screw, Appliance Inlet, IEC C14, For PCB mounting, IP 40, Quick connect terminals 4.8 x 0.8 mm  
angled or straight, Suitable for appliances with protection class I or II  
GSP1  
...  
Appliance Inlet further types to 6051.2037  
2
Connectors  
Cord Sets  
6051.2037  
https://www.schurter.com /PG07  
IEC Inlet Filter Overview complete  
5123, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast  
/ steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II  
5123  
5120  
5150  
KFS  
5120, Mounting: Screw with plastic flange, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder:  
10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II  
5150, Mounting: Screw, Front-/Rear-Side, Filter: Standard, medical and industrial version, Without fuse holder: 10 A,  
Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I  
KFS, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, pre-  
wired  
IEC Inlet Filter further types to 6051.2037  
Power Entry Module Overview complete  
DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals  
4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appli-  
ances with protection class I  
DD11  
DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick  
connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuse holder: 1 or 2 pole  
DD21  
DC11  
DC21  
DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8  
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II  
DC21, Mounting: Screw Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8  
x 0.8 mm Appliance Inlet: IEC C14, Without fuse holder:  
KD, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, voltage selector: 2-4 digits, Fuse holder: 1 or 2 pole,  
Rocker switch, non-illuminated, 2-pole, V-Lock cord retaining, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for KD  
appliances with protection class I  
Power Entry Module further types to 6051.2037  
...  
Power Entry Module with line filter Overview complete  
Mounting: Screw, from rear-side, A, Filter: Standard Version, Rocker switch: 2-pole, non-illuminated, : IEC C14, Suitable  
for appliances with protection class I or II  
DA22  
DC12  
DC22  
DD12  
DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker  
switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired  
DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch:  
1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I  
DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuse holder:1 or 2 pole, 10 A,  
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired  
DD22 Mounting: Screw-on mounting, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Fuse holder: 1 or 2  
pole, Rocker switch: 2-pole, non-illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I  
DD22  
...  
Power Entry Module with line filter further types to 6051.2037  
Mating Outlets/Connectors shuttered  
Appliance Outlet Overview complete  
IEC Appliance Outlet F, Integrated Light Pipes, PCB terminals, Color Coding  
Appliance Outlet further types to 6051.2037  
6600-5  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments. Information furnished is believed  
to be accurate and reliable. However, users should independently evaluate the suitability and test each  
product selected for their own applications.  
3
Connectors  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY