SKCD53C120I4F [SEMIKRON]
CAL-DIODE; CAL二极管型号: | SKCD53C120I4F |
厂家: | SEMIKRON INTERNATIONAL |
描述: | CAL-DIODE |
文件: | 总2页 (文件大小:187K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SKCD 53 C 120 I4F
Absolute Maximum Ratings
Symbol Conditions
Values
Unit
Tj = 25 °C, IR = 0.12 mA
Tc = 80 °C, Tj = 175 °C, Fi=PI/2
VRRM
IF(AV)
IFSM
1200
61
550
550
175
V
A
A
A
°C
Tj = 25 °C
Tj = 150 °C
10 ms
sin 180°
Tjmax
Electrical Characteristics
Symbol Conditions
CAL-DIODE
min.
typ.
max.
Unit
IF = 100 A
VRRM = 1200 V
Size: 7,3 mm x 7,3 mm
Tj = 150 °C, sin 180°, 10 ms
Tj = 25 °C, VRRM = 1200 V
i²t
IR
1513
0.12
17.70
2.52
2.47
2.31
1.10
13.70
0.98
A²s
mA
mA
V
V
V
V
m
V
Tj = 150 °C, VRRM = 1200 V
Tj = 25 °C, IF = 100 A
Tj = 150 °C, IF = 100 A
Tj = 175 °C, IF = 100 A
Tj = 150 °C
Tj = 150 °C
Tj = 175 °C
Tj = 175 °C
8.80
2.20
2.15
2.00
0.90
12.5
0.82
11.80
VF
V(TO)
rT
V(TO)
rT
SKCD 53 C 120 I4F
Features
13.40
m
• max. junction 175 °C
Dynamic Characteristics
Symbol Conditions
• very low forward voltage drop
• positive temperature coefficient
• extreme soft recovery
min.
min.
typ.
max.
Unit
Tj = 150 °C, 100 A, 600 V, 2000 A/µs
Tj = 150 °C, 100 A, 600 V, 2000 A/µs
Tj = 150 °C, 100 A, 600 V, 2000 A/µs
trr
Err
Irrm
0.5
5.4
97
µs
mJ
A
Typical Applications*
• freewheeling diode for IGBT
Thermal Characteristics
Symbol Conditions
typ.
max.
Unit
Tj
Tstg
Tsolder
Tsolder
Rth(j-c)
-40
-40
175
175
250
320
°C
°C
°C
°C
K/W
10 min.
5 min.
Semitrans Assembly
0.52
Mechanical Characteristics
Symbol Conditions
Values
Unit
Raster
size
Area total
7,3 x 7,3
mm2
mm²
53
Anode
Metallization
Metallization
bondable (Al)
Cathode
Wire bond
Package
solderable (Ag/Ni)
Al, typ. diameter = 300 µm
wafer frame
Chips /
Package
270
pcs
SKCD
© by SEMIKRON
Rev. 0 – 16.03.2011
1
SKCD 53 C 120 I4F
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
2
Rev. 0 – 16.03.2011
© by SEMIKRON
相关型号:
©2020 ICPDF网 联系我们和版权申明