40PC001G3A [SENSORTECHNICS]
Fully signal conditioned pressure transducer; 完全信号调理压力传感器型号: | 40PC001G3A |
厂家: | SENSORTECHNICS GMBH |
描述: | Fully signal conditioned pressure transducer |
文件: | 总8页 (文件大小:193K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
40PC Series
Fully signal conditioned pressure transducer
FEATURES
· Pressure ranges from 0 ... ± 50 mmHg
to 0 ... 500 psi gage
· High accuracy
· TTL power supply
· Ratiometric 0.5 to 4.5 V output
· Dual-Inline pinning for easy
PCB-mounting
· Excellent media compatibility
MEDIA COMPATIBILITY
P1: dry gases only
P2: all media compatible with glass, silicon, stain-
less steel, Invar, Sn/Ni plating or Sn/Ag solder
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage (VS)
4.75 ... 5.25 V
Output current
Source
0.5 mA
1.0 mA
Sink
Output load capacitance
10 nF
Temperature limits
Operating
NOTES:
-45 to +125°C
-55 to +125°C
-45 to +125°C
1. Square corner
marks pin 1 (Vs)
Storage
Compensated
2. Output is short
circuit protected
Humidity (non-condensing)
0 - 95 %RH
November 2007 / 573
1/8
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
PRESSURE RANGE SPECIFICATIONS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Part number
40PC001B2A
40PC006G2A
40PC015G2A
40PC015V2A
40PC030G2A
40PC100G2A
40PC150G2A
40PC250G2A
40PC500G2A
Operating pressure range
0 ... ±50 mmHg
0 ... 300 mmHg
0 ... 15 psig
Proof pressure1
170 mmHg
650 mmHg
45 psi
Sensitivity (typ.)
40.0 mV/mmHg
13.33 mV/mmHg
266.7 mV/psi
-266.7 mV/psi
133.3 mV/psi
40.0 mV/psi
0 ... -15 psig
30 psi
0 ... 30 psig
60 psi
0 ... 100 psig
200 psi
0 ... 150 psig
300 psi
25.7 mV/psi
0 ... 250 psig
500 psi
16.0 mV/psi
0 ... 500 psig
1000 psi
8.0 mV/psi
Specification notes:
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through
three points (offset pressure, full scale pressure and 1/2 full scale pressure).
1.
2.
Thermal effects tested and guaranteed in the specified temperature ranges relative to 25°C. All specifications shown
are relative to 25°C.
3.
Span is the algebraic difference between lowest and highest specified pressure.
4.
5.
Total accuracy is the maximum deviation from the 25°C reference transfer function at any pressure or temperature over
the specified ranges. This calculation includes null, span, linearity, hysteresis, repeatability, null shift and span shift.
Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure.
6.
2/8
November 2007 / 573
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
40PC001B2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics Min.
Typ.
Max.
+50
Unit
Operating pressure
Zero pressure offset
Span4
-50
mmHg
2.45
2.50
4.0
2.55
V
Output
at -50 mmHg
at +50 mmHg
Offset
0.5
4.5
Thermal effects (0 to 50°C)3
±1.50
±1.50
±0.8
Span
Non-linearity (BSL)2
%FSS
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
±0.15
±0.25
10.0
mA
ms
1
40PC006G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Zero pressure offset
Span4
Min.
0
Typ.
Max.
Unit
300
0.55
4.05
mmHg
0.45
3.95
0.50
4.00
4.5
V
Full scale output
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +125°C
-18 to +63°C
-45 to +125°C
±1.25
±2.75
±0.75
±2.0
Combined offset and span -18 to +63°C
-45 to +125°C
±1.5
%FSS
±4.0
Total accuracy5
-45 to +125°C
±4.0
Non-linearity (BSL)2
±0.2
Hysteresis and repeatability
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
±0.15
±0.25
10.0
mA
ms
1
November 2007 / 573
3/8
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
40PC015G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
15
Unit
psig
Zero pressure offset
Span4
0.39
3.89
0.50
4.00
4.5
0.61
4.11
V
Full scale output
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-18 to +63°C
-45 to +85°C
±2.0
±2.75
±0.75
±1.0
±2.0
±3.0
±4.0
±0.2
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
Total accuracy5
Non-linearity (BSL)2
-45 to +85°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
40PC015V2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
-15
Unit
psig
Zero pressure offset
Span4
0.46
3.9
0.50
4.0
0.54
4.1
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +25°C
-45 to +85°C
-18 to +25°C
+25 to +85°C
-45 to +25°C
±0.75
±1.0
±2.0
±1.25
±2.25
±1.5
Combined offset and span -18 to +25°C
+25 to +85°C
%FSS
±1.0
-40 to +25°C
±1.75
±2.25
±0.3
Total accuracy5
Non-linearity (BSL)2
+45 to +85°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
4/8
November 2007 / 573
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
40PC030G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
30
Unit
psig
Zero pressure offset
Span4
0.46
3.92
0.50
4.00
4.5
0.54
4.08
V
Full scale output
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±1.5
±2.0
±2.25
±1.5
±2.0
±2.25
±2.0
%FSS
Combined offset and span -18 to +63°C
-45 to +125°C
±2.25
±2.25
±0.3
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
40PC100G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
100
Unit
psig
Zero pressure offset
Span4
0.46
3.91
0.50
4.0
0.54
4.09
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±1.25
±2.0
±3.0
±0.75
±1.0
±2.0
±1.5
±2.5
±3.0
±3.0
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
November 2007 / 573
5/8
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
40PC150G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
150
Unit
psig
Zero pressure offset
Span4
0.46
3.93
0.50
4.0
0.54
4.07
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±0.75
±1.0
±1.5
±2.5
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
40PC250G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
250
Unit
psig
Zero pressure offset
Span4
0.46
3.93
0.50
4.0
0.54
4.07
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±0.75
±1.0
±2.0
±0.75
±1.0
±2.0
±0.75
±1.0
±3.0
±3.0
±0.1
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
6/8
November 2007 / 573
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
40PC500G2A
PERFORMANCE CHARACTERISTICS
(unless otherwise noted, VS = 5.00 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure
Min.
0
Typ.
Max.
500
Unit
psig
Zero pressure offset
Span4
0.46
3.91
0.50
4.0
0.54
4.09
V
Full scale output
4.5
Thermal effects3
Offset
Span
-18 to +63°C
-45 to +85°C
-45 to +125°C
-18 to +63°C
-45 to +85°C
-45 to +125°C
±1.0
±1.5
±2.5
±0.75
±1.0
±1.5
±1.0
±1.75
±3.0
±3.0
±0.2
Combined offset and span -18 to +63°C
-45 to +85°C
%FSS
-45 to +125°C
Total accuracy5
Non-linearity (BSL)2
-45 to +125°C
Hysteresis and repeatability
±0.15
±0.25
Ratiometricity error (VS = 4.75 ... 5.25 V)
Current consumption (no load)
Response time6
10.0
mA
ms
1
OUTLINE DRAWING
mass: 4 g
dimensions in mm (inches)
November 2007 / 573
7/8
www.sensortechnics.com
40PC Series
Fully signal conditioned pressure transducer
ORDERING INFORMATION
40PC
xxx
x
xA
40PC series
Lead forming
1: unformed (straight)
2: formed away from port
3: formed towards port
Pressure range
001: 0 ... ±50 mmHg
006: 0 ... 300 mmHg
2: stocking devices
1, 3: call Sensortechnics for availability
015:
015:
030:
100:
150:
250:
500:
0 ... 15 psi
0 ... -15 psi
0 ... 30 psi
0 ... 100 psi
0 ... 150 psi
0 ... 250 psi
0 ... 500 psi
Pressure mode
B: bidirectional gage pressure: available for ±50 mmHg only
G: gage pressure
V: vacuum gage: available for -15 psi only
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
8/8
November 2007 / 573
www.sensortechnics.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明