SCC100A [SENSORTECHNICS]
Pressure sensors; 压力传感器型号: | SCC100A |
厂家: | SENSORTECHNICS GMBH |
描述: | Pressure sensors |
文件: | 总5页 (文件大小:104K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SCC Series
Pressure sensors
FEATURES
GENERAL DESCRIPTION
·
·
·
0...5 to 0...100 psi
The SCC series offer an extremely low
cost sensor element with a temperature
stable output when driven with a constant
current source. These integrated circuit
sensors were designed for extremely cost
sensitive applications where precise accu-
racy over a wide temperature range is not
required. This series is intended for use
with non-corrosive, non-ionic working fluids
such as air and dry gases.
Low cost sensor element
Internal temperature
compensation
·
Differential, gage and
absolute
Absolute devices have an internal vacuum
reference and an output voltage proportio-
nal to applied pressure. The differential de-
vices allow application of pressure to either
side of the diaphragm and the devices are
thereby available to measure both differen-
tial and/or gage pressures.
APPLICATIONS
Scale:
1 cm
½ inch
·
·
·
·
·
Pneumatic controls
Automotive diagnostics
Medical equipment
Dental equipment
This product is packaged either in SenSym's
standard low cost chip carrier "button"
package, a plastic ported "N" package or a
dual inline package (DIP). All packages are
designed for applications where the
sensing element is to be integral to the OEM
equipment. These packages can be o-ring
sealed, epoxied, and/or clamped onto a
pressure fitting. closed bridge
4-pin SIP configuration is provided for elec-
trical connection to the button package. The
DIP package offer a 5-pin open bridge
configuration.
A
Environmental controls
EQUIVALENT CIRCUIT
ELECTRICAL CONNECTION
Vs
GND 1
out + 2
P1
3
4
+VS
out -
+
Output
SCC..
button sensor
-
Button Sensor or "N" Package
+Vs
+Vs
out +
+Vs
+Vs
out -
GND
out +
+Vs
+Vs
out +
1
1
1
P2
P1
P1
GND
out -
GND
out -
Vs
P2
4
4
4
vent hole
SCCxxxGD2
DIP
SCCxxxAD2
DIP
-
SCCxxxD4
DIP
Output
The polarity indicated is for pressure applied to
SCC.../SCC...N
SCC...GD2
SCC...ASO/GSO: P1 (forward gage)
:
:
P1 (forward gage)
P2 (backward gage)
+
SCC...AD2
SCC...DD4
:
:
P1 (forward gage)
P2 (backward gage)
DIP Package
July 2005 / 040
1/5
www.sensortechnics.com
SCC Series
Pressure sensors
PRESSURE SENSOR CHARACTERISTICS
Maximum ratings (for all devices)
Supply current, IS
1.5 mA
Humidity
0 to 100 %RH
250°C
Temperature ranges
Compensated
Operating
Lead temperature (soldering 4 sec.)
Common-mode pressure
0 to +50°C
-40 to +85°C
-55 to +125°C
150 psi
Storage
PERFORMANCE CHARACTERISTICS (individual models) IS = 1.0 mA, TA = 25°C1
Operating
pressure
range
Effect
Effect
Full-scale
span1,5
(mV)
Proof
on span3
(0 - 50°C)
on offset4
(0 - 50°C)
Part number
pressure9
Accuracy2
SCC05(D,G)
SCC15A
SCC15(D,G)
SCC30A
SCC30(D,G)
SCC100A
SCC100(D,G)
0 - 5 psid(g)
0 - 15 psia
0 - 15 psid(g)
0 - 30 psia
0 - 30 psid(g)
0 - 100 psia
0 - 100 psid(g)
20 psi
30 psia
30 psi
60 psia
60 psi
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
0.50 %
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
1.50 %
2.00 %
2.00 %
2.00 %
2.00 %
2.00 %
2.00 %
2.00 %
25 - 65
30 - 95
40 - 95
60 - 150
60 - 150
85 - 225
85 - 225
150 psia
150 psi
PERFORMANCE CHARACTERISTICS (all models) IS = 1.0 mA, TA = 25°C
Characteristics
Min.
Typ.
Max.
Unit
Zero pressure offset
-30.0
---
---
---
---
---
4.00
4.00
-10
20.0
0.50
1.50
2.00
---
---
6.50
6.50
mV
%FSO
%FSO
%FSO
mV
ms
kΩ
kΩ
Combined linearity, hysteresis, repeatability2
Temperature effect on span3,8
Temperature effect on offset4,8
Long term stability of offset and span6
Response time (10 to 90 %)7
Input impedance
0.25
0.25
0.50
0.10
0.10
5.00
5.00
Output impedance
Specification notes:
Reference conditions: supply current = 1.0 mA, TA=25°C, common-mode line pressure = 0 psig, pressure applied to P1, unless
otherwise noted.
Accuracy is the sum of hysteresis and linearity. Hysteresis is the maximum output difference at any point within the operating
pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the
offset, full-scale and 1/2 full-scale pressure at 25°C.
1.
2.
This is the maximum temperature shift for span when measured between 0 and 50°C relative to the 25°C reading.
Typical temperature coefficients for span and resistance are -2200 and +2200 ppm/°C respectively.
This is the maximum temperature shift for offset when measured between 0 and 50°C relative to the 25°C reading.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Maximum difference in output at any pressure with the operating pressure range and temperature within 0 to 50°C after:
a) 100 temperature cycles, 0 to 50°C.
3.
4.
5.
6.
b) 1.0 million pressure cycles, 0 psi to full-scale span.
Response time for a 0 psi to full-scale span pressure step change. 10 to 90 % rise time.
Temp. effect on span and offset are guaranteed by design. Therefore these parameters are not 100 % tested.
If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
Note: The proof pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi whatever is
less. The SCC100D (button package) can be used in forward gage mode only when the pressure doesn't exceed 30 psi,
or no special care ist taken.
7.
8.
9.
2/5
July 2005 / 040
www.sensortechnics.com
SCC Series
Pressure sensors
PHYSICAL DIMENSIONS
Button package
mass: 1 g
dimensions in inches (mm)
Basic sensor DIP "D2" package
mass: 1 g
dimensions in inches (mm)
3/5
July 2005 / 040
www.sensortechnics.com
SCC Series
Pressure sensors
PHYSICAL DIMENSIONS (cont.)
Basic sensor DIP "D4" package
0.550
(13.97)
P1
0.470
(11.94)
0.050
typ.
(1.27)
P2
0.090 typ.
(2.29)
0.300
(7.62)
0.135
(3.43)
0.380
(9.65)
0.250
(6.35)
0.285
(7.24)
0.110 typ.
(2.79)
0.070
(1.78)
0.020 typ.
(0.51)
0.01
(0.25)
0.600
(15.24)
0.100 typ.
(2.54)
mass: 1 g
dimensions in inches (mm)
N package
mass: 5 g
dimensions in inches (mm)
4/5
July 2005 / 040
www.sensortechnics.com
SCC Series
Pressure sensors
ORDERING INFORMATION
Part number
DIP package
Pressure range
Button
package
DIP package
dual port
"N" package
single port
SCC15AD2
SCC30AD2
SCC100AD2
SCC05GD2
SCC15GD2
SCC30GD2
SCC100GD2
0...15 psi
SCC15A
SCC30A
SCC100A
SCC15AN
SCC30AN
SCC100AN
Absolute
0...30 psi
pressure
0...100 psi
0...5 psi
use
differential
devices
use
0...15 psi
Gage
differential
devices
pressure
0...30 psi
0...100 psi
0...5 psi
SCC05D
SCC15D
SCC30D
SCC100D
SCC05DN
SCC15DN
SCC30DN
SCC100DN
SCC05DD4
SCC15DD4
SCC30DD4
SCC100DD4
0...15 psi
Differential
pressure
0...30 psi
0...100 psi
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any
liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent
rights nor the rights of others.
July 2005 / 040
5/5
www.sensortechnics.com
©2020 ICPDF网 联系我们和版权申明