1018237 [SICK]

MULTIPLE LIGHT BEAM SAFETY DEVICES;
1018237
型号: 1018237
厂家: SICK AG    SICK AG
描述:

MULTIPLE LIGHT BEAM SAFETY DEVICES

文件: 总6页 (文件大小:1112K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
M20S-091A3A122, M20E-091A3A222  
M2000 RES/EDM  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
M20S-091A3A122, M20E-091A3A222 | M2000 RES/EDM  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Ordering information  
A
B
C
D
E
F
System part  
Sender  
Type  
Part no.  
1018200  
1018237  
M20S-091A3A122  
M20E-091A3A222  
Receiver  
1.) Concerns installation as a replacement part for previous type 2 device in machine: Regarding Machinery Directive  
2006/42/EC, Article 1, Paragraph (2a) this type 2 device may only be used as a replacement part for identical PL d / SIL2  
devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documen-  
tation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.)  
Concerns installation on new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only  
be installed on new machines up to PL c / SIL1 as of 2015-05-10.  
Other models and accessories www.sick.com/M2000_RES_EDM  
Detailed technical data  
Safety-related parameters  
Type  
Type 2 (IEC 61496)  
SIL1 (IEC 61508)  
SILCL1 (EN 62061)  
Safety integrity level  
H
I
Category 2 (EN ISO 13849)  
13 /s (EN ISO 13849) 1)  
Category  
Test rate (internal test)  
≤ 8 min⁻¹ (EN ISO 13849) 2)  
Maximum demand rate  
Performance level  
J
PL c (EN ISO 13849)  
6.6 x 10-9 (EN ISO 13849)  
PFHD (mean probability of a dangerous fail-  
ure per hour)  
K
L
20 years (EN ISO 13849)  
TM (mission time)  
At least one OSSD is in the OFF state.  
Safe state in the event of a fault  
1)  
Internal test. The test rate may not be exceeded if an external test is performed.  
2)  
Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.  
M
N
O
P
Q
R
S
T
Functions  
Functions  
Delivery status  
Restart interlock  
Uncoded  
Beam coding  
Configurable scanning range  
Interfaces  
System connection  
Connection type Male connector M12, 8-pin  
Conductor cross-section 0.25 mm²  
≤ 15 m 1)  
Permitted cable length  
Permitted cross-section ≥ 0.25 mm²  
1)  
2)  
Depending on load, power supply and wire cross-section. The technical specifications must be observed.  
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.  
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-06-14 08:06:28  
Subject to change without notice  
M20S-091A3A122, M20E-091A3A222 | M2000 RES/EDM  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Hard wired  
Configuration method  
Display elements  
LEDs  
7-segment display  
Fieldbus, industrial network  
CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2)  
Integration via Flexi Soft safety controller  
1)  
Depending on load, power supply and wire cross-section. The technical specifications must be observed.  
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.  
2)  
Electrical data  
III (EN 50178)  
Protection class  
Supply voltage VS  
24 V DC (19.2 V DC ... 28.8 V DC) 1)  
≤ 3.7 W (DC)  
Power consumption  
Safety outputs (OSSD)  
Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored  
1)  
The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as  
accessories from SICK.  
Mechanical data  
48 mm x 40 mm  
Housing cross-section  
Ambient data  
IP65 (EN 60529)  
Enclosure rating  
0 °C ... +55 °C  
Ambient operating temperature  
Storage temperature  
Air humidity  
–25 °C ... +70 °C  
15 % ... 95 %, Non-condensing  
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)  
10 g, 16 ms (IEC 60068-2-29)  
Vibration resistance  
Shock resistance  
Other information  
950 nm  
Wave length  
2017-06-14 08:06:28 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
3
M20S-091A3A122, M20E-091A3A222 | M2000 RES/EDM  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Dimensional drawing (Dimensions in mm (inch))  
A
B
C
D
E
F
1.7  
(0.07)  
8
(0.31)  
42.9  
(1.69)  
2
1
Ø 8.4  
3 (0.33)  
4
11.9  
(0.47)  
20  
(0.79)  
48  
(1.89)  
5
14  
40  
(1.57)  
(0.55)  
6
(0.24)  
42.3  
(1.67)  
10.5  
(0.41)  
22.4  
(0.88)  
25.6  
(1.01)  
H
I
42.6  
(1.68)  
J
6
Number  
of beams  
Beam sep-  
aration  
Resolution  
L1  
L2  
L3  
L4  
L5  
L6  
K
L
2
3
4
6
7
8
8
9
500 (19.69)  
-
630 (24.80)  
931 (36.65)  
697 (27.44)  
998 (39.29)  
588 (23.15)  
718 (28.27)  
655 (25.79)  
675 (26.57)  
976 (38.43)  
400 (15.75)  
-
888 (34.96) 1,019 (40.12) 956 (37.64)  
300 (11.81)  
-
1,031 (40.59) 1,098 (43.23) 989 (38.94) 1,119 (44.06) 1,056 (41.57) 1,076 (42.36)  
916 (36.06) 983 (38.70) 874 (34.41) 1,004 (39.53) 941 (37.05) 960 (37.80)  
1,073 (42.24) 1,140 (44.88) 1,031 (40.59) 1,161 (45.71) 1,098 (43.23) 1,118 (44.02)  
851 (33.50) 919 (36.18) 809 (31.85) 939 (36.97) 877 (34.53) 896 (35.28)  
-
-
-
-
-
170 (6.69)  
170 (6.69)  
116 (4.57)  
170 (6.69)  
170 (6.69)  
M
N
O
P
Q
R
S
T
1,231 (48.46) 1,298 (51.10) 1,189 (46.81) 1,319 (51.93) 1,256 (49.45) 1,275 (50.20)  
1,388 (54.65) 1,455 (57.28) 1,346 (52.99) 1,476 (58.11) 1,413 (55.63) 1,433 (56.42)  
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-06-14 08:06:28  
Subject to change without notice  
M20S-091A3A122, M20E-091A3A222 | M2000 RES/EDM  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Recommended accessories  
Other models and accessories www.sick.com/M2000_RES_EDM  
Brief description  
Type  
Part no.  
Mounting brackets and plates  
4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws  
BEF-3WNGBAST4  
7021352  
and washers  
Terminal and alignment brackets  
4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast  
BEF-1SHABAZN4  
BEF-2SMMEAAL4  
BEF-2SMMEAKU4  
2019506  
2044847  
2019659  
4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on the  
swivel mount  
4 pieces, Mounting kit 2, rotatable, swivel mount, Polyamide PA6  
Alignment aids  
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into  
the beam!  
AR60  
1015741  
4032461  
4056731  
Adapter AR60 for housing cross-section 48 mm x 40 mm  
AR60 adapter, 48x40  
Adapter AR60 for housing cross-section 48 mm x 40 mm in PU3H device column  
AR60 adapter,  
48x40, PU3H  
2017-06-14 08:06:28 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
5

相关型号:

101830-HMC214MS8

BOARD EVAL HMC214MS8E
ADI

1018306

Barrier Strip Terminal Block,
PHOENIX

1018331

BAR CODE SCANNERS
SICK

1018334

BAR CODE SCANNERS
SICK

101833U010BB2B

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 10V, 83000uF, CHASSIS MOUNT
CDE

1018488

Cable Assembly,
PHOENIX

101853U030CC2B

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 30V, 85000uF, CHASSIS MOUNT
CDE

1018594

GENERAL PURPOSE CHIP RESISTORS
YAGEO

10186GY-GB

DEHUMIDIFIER LIGHT INDUSTRIAL
ETC

1018727

Cable Assembly,
PHOENIX

101872U030AA2B

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 30V, 75% +Tol, 10% -Tol, 8700uF, Chassis Mount
CDE

101873U016BC2B

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 87000uF, CHASSIS MOUNT
CDE