6054762 [SICK]

SAFETY LOCKING DEVICES;
6054762
型号: 6054762
厂家: SICK AG    SICK AG
描述:

SAFETY LOCKING DEVICES

文件: 总8页 (文件大小:378K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TR10-SRU03P  
TR10 Lock  
SAFETY LOCKING DEVICES  
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
Ordering information  
A
B
C
D
E
F
Type  
TR10-SRU03P  
Part no.  
6054762  
Other models and accessories www.sick.com/TR10_Lock  
Detailed technical data  
Features  
H
I
Transponder  
2
Sensor principle  
Number of safe outputs  
Coding  
Uniquely coded  
1,690 N (EN ISO 14119)  
Locking force Fmax  
With straight actuator EN ISO 14119  
J
With angled actuator EN ISO 14119  
With hinged actuator EN ISO 14119  
K
L
1,300 N (EN ISO 14119)  
Locking force FZh  
Actuation directions  
Approach speed  
4
≥ 2 mm/s  
Safety-related parameters  
Safety integrity level  
Category  
M
N
O
P
Q
R
S
T
SIL3 (IEC 61508)  
Category 4 (EN ISO 13849)  
PL e (EN ISO 13849)  
Performance level  
9.1 x 10-10 (EN ISO 13849)  
PFHD (mean probability of a dangerous fail-  
ure per hour)  
20 years (EN ISO 13849)  
Type 4 (EN ISO 14119)  
TM (mission time)  
Type  
High coding level (EN ISO 14119)  
Actuator coding level  
Safe state in the event of a fault  
At least one safety-related semiconductor output (OSSD) is in the OFF state.  
Functions  
Cascading  
Interfaces  
Cable  
Connection type  
2
SAFETY SWITCHES | SICK  
Online data sheet | 2018-07-20 14:43:28  
Subject to change without notice  
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
Length of cable 3 m  
Cable material PVC  
Connecting cable length ≤ 200 m  
Electrical data  
II (IEC 61140)  
Protection class  
3
Contamination rating  
Classification according to cULus  
Usage category  
Class 2  
DC-13 (IEC 60947-5-1)  
200 mA (24 V DC)  
75 V  
Rated operating current (voltage)  
Rated insulation voltage Ui  
Rated impulse withstand voltage Uimp  
Supply voltage VS  
1,000 V  
24 V DC (20.4 V DC ... 26.4 V DC)  
Semiconductor (OSSD)  
≤ 200 mA  
Type of output  
Output current  
400 mA, 100 ms 1)  
2.5 W  
Peak current  
Power consumption  
Response time  
100 ms for the first switch, 50 ms for each subsequent switch 2)  
600 ms  
Enable time  
100 ms  
Risk time  
7 s  
Switch-on time  
Locking principle  
Power to release  
1)  
During switching on, locking, or unlocking.  
2)  
Time until the outputs are switched off.  
Mechanical data  
Weight  
0.4 kg  
ABS  
Housing material  
Locking bolt material  
Mechanical life  
Stainless steel 304  
5 x 105 switching cycles  
Ambient data  
IP66 (IEC 60529)  
IP67 (IEC 60529)  
IP69K (IEC 60529)  
Enclosure rating  
0 °C ... +55 °C  
Ambient operating temperature  
Storage temperature  
Vibration resistance  
Shock resistance  
EMC  
–25 °C ... +75 °C  
10 Hz ... 55 Hz (IEC 60068-2-6)  
30 g, 11 ms (EN 60068-2-27)  
IEC 60947-5-3  
Classifications  
ECl@ss 5.0  
27272603  
27272603  
27272603  
ECl@ss 5.1.4  
ECl@ss 6.0  
2018-07-20 14:43:28 | Online data sheet  
Subject to change without notice  
SAFETY SWITCHES | SICK  
3
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
27272603  
27272603  
27272603  
27272603  
27272603  
EC002593  
EC002593  
39122205  
ECl@ss 6.2  
ECl@ss 7.0  
ECl@ss 8.0  
ECl@ss 8.1  
ECl@ss 9.0  
ETIM 5.0  
A
B
C
D
E
F
ETIM 6.0  
UNSPSC 16.0901  
Dimensional drawing (Dimensions in mm (inch))  
Sensor with cable  
33  
(1.3)  
10  
(0.39)  
Ø 9.525  
(Ø 0.37)  
H
I
J
22.5  
(0.89)  
8
(0.31)  
9.5  
(0.37)  
K
L
Ø 6.5  
(Ø 0.26)  
M
N
O
P
Q
R
S
T
22.5  
(0.89)  
45  
(1.77)  
4
SAFETY SWITCHES | SICK  
Online data sheet | 2018-07-20 14:43:28  
Subject to change without notice  
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
Actuator and mounting bracket  
51.5  
(2.03)  
40  
(1.57)  
12.5  
(0.49)  
3
(0.12)  
25  
(0.98)  
Connection diagram  
WH  
BN  
GN  
YE  
GY  
PK  
BU  
RD  
White  
Aux output (not safe)  
Brown Voltage supply 24 V DC  
Green Lock control  
Yellow OSSD 2 input  
Gray  
Pink  
Blue  
Red  
OSSD 1 output  
OSSD 2 output  
Voltage supply 0 V DC  
OSSD 1 input  
2018-07-20 14:43:28 | Online data sheet  
Subject to change without notice  
SAFETY SWITCHES | SICK  
5
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
Series connection  
A
B
C
D
E
F
Series connection with T-piece (without diagnostics)  
1
1
1
1
1
2
2
2
2
2
7
6
H
I
3
4
5
4
5
4
5
4
5
4
TR10 Lock safety locking device  
Connection cable with 8-pin, M12 male connector and 8-pin, M12 female connector (e.g., DSL-1208-xxxxx)  
MLP1-XXT end connector  
TR4-AK004C T-connector  
Connection cable with 5-pin, M12 male connector and 5-pin, M12 female connector (e.g., DSL-1205-xxxxx)  
Connecting cable with 5-pin, M12 female connector and flying leads (e.g., DOL-1205-xxxxx)  
Safe evaluation unit  
J
TR10 Lock safety locking device to UE48-2OS safety relay  
K
L
+24 V DC  
BN RD YE GN  
2
7
8
4
TR10 Lock  
3
Lock/  
Unlock  
5
6
1
M
N
O
P
Q
R
S
T
BU GY PK WH  
Reset  
S33 S11 S12 S31 A1 13 23 31  
I1  
PLC  
k1  
k2  
UE48-2OS3D2  
S34 S35 S21 S22 A2 14 24 32  
K1  
K2  
0 V  
E156017/00/2016-06-09  
6
SAFETY SWITCHES | SICK  
Online data sheet | 2018-07-20 14:43:28  
Subject to change without notice  
TR10-SRU03P | TR10 Lock  
SAFETY LOCKING DEVICES  
Series connection of three TR10 Lock safety locking devices to a Flexi Classic safety controller  
+24 V DC  
BN RD YE GN  
2
7
8
4
TR10 Lock  
3
1
5
6
BU GY PK WH  
BN RD YE GN  
Reset  
2
7
8
4
TR10 Lock  
3
1
5
6
BU GY PK WH  
k1  
k2  
BN RD YE GN  
2
7
8
4
TR10 Lock  
3
1
5
6
BU GY PK WH  
I1 I2 A1 X1 X2 S1 S2 S3  
Lock/  
Unlock  
8
Function  
FE  
UE410-MU/XU  
I3 I4 A2 Q1 Q2 Q3 Q4 EN  
K1  
K2  
0 V  
FE  
E156014/00/2016-06-09  
Recommended accessories  
Other models and accessories www.sick.com/TR10_Lock  
Brief description  
Type  
Part no.  
Nuts and screws  
10 pieces, Safety screws for mounting bracket of actuator  
Safety screws M5 x 10  
5334497  
2018-07-20 14:43:28 | Online data sheet  
Subject to change without notice  
SAFETY SWITCHES | SICK  
7

相关型号:

6054763

SAFETY LOCKING DEVICES
SICK

6054766

SAFETY LOCKING DEVICES
SICK

6054767

SAFETY LOCKING DEVICES
SICK

6055

SINGLE POLE, THREE THROW CONNECTORIZED SWITCHES
MICRONETICS

6055-034

Split Bobbin Power Transformer, 48VA
API

6055-056

Split Bobbin Power Transformer, 48VA
API

6055-230

Split Bobbin Power Transformer, 48VA
API

6055-50

Barrier Strip Terminal Block, 10A, 1 Row(s), 1 Deck(s)
MOLEX

6055-58

Barrier Strip Terminal Block, 10A, 1 Row(s), 1 Deck(s)
MOLEX

6055-59

Barrier Strip Terminal Block, 10A, 1 Row(s), 1 Deck(s)
MOLEX

6055R-056

Split Bobbin Power Transformer, 48VA, ROHS COMPLIANT
API

6056

SINGLE POLE, THREE THROW CONNECTORIZED SWITCHES
MICRONETICS