M40S-61A005AA0 [SICK]

MULTIPLE LIGHT BEAM SAFETY DEVICES;
M40S-61A005AA0
型号: M40S-61A005AA0
厂家: SICK AG    SICK AG
描述:

MULTIPLE LIGHT BEAM SAFETY DEVICES

文件: 总8页 (文件大小:1578K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
M40S-63A105AA0, M40E-63A105RA0  
M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Ordering information  
A
B
C
D
E
F
System part  
Sender  
Type  
Part no.  
1200134  
1200685  
M40S-63A105AA0  
M40E-63A105RA0  
Receiver  
Other models and accessories www.sick.com/M4000_Area  
Detailed technical data  
Features  
0.5 m ... 70 m, configurable  
0.5 m ... 20 m  
9 m ... 70 m  
Scanning range  
Low scanning range  
Great scanning range  
Length of the monitored area  
Resolution  
H
I
750 mm  
80 mm  
17 ms  
Response time  
J
Optical synchronisation  
Synchronization  
Safety-related parameters  
Type  
K
L
Type 4 (IEC 61496)  
SIL3 (IEC 61508)  
SILCL3 (EN 62061)  
Safety integrity level  
Category 4 (EN ISO 13849)  
PL e (EN ISO 13849)  
Category  
Performance level  
M
N
O
P
Q
R
S
T
1.4 * E-08 (EN ISO 13849)  
PFHD (mean probability of a dangerous fail-  
ure per hour)  
20 years (EN ISO 13849)  
TM (mission time)  
At least one OSSD is in the OFF state.  
Safe state in the event of a fault  
Functions  
Functions  
Delivery status  
Internal  
Restart interlock  
Activated  
External device monitoring (EDM)  
Beam coding  
Uncoded  
Deactivated  
0.5 m ... 20 m  
Contamination (OWS)  
Sender test  
Configurable scanning range  
Configurable application diagnostic output  
Safe SICK device communication via EFI  
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-08-24 18:11:25  
Subject to change without notice  
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Interfaces  
System connection  
Connection type Hirschmann male connector M26, 12-pin  
Permitted cable length  
≤ 50 m 1)  
Permitted cross-section ≥ 0.75 mm²  
PC with CDS (Configuration and Diagnostic Software)  
Configuration method  
Configuration connection  
Connection type Female connector M8, 4-pin  
LEDs  
Display elements  
7-segment display  
Fieldbus, industrial network  
CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 2)  
Integration via EFI gateways  
CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 3)  
Integration via Flexi Soft safety controller  
1)  
2)  
3)  
Depending on load, power supply and wire cross-section. The technical specifications must be observed.  
For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems.  
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.  
Electrical data  
Protection class  
Supply voltage VS  
III (EN 50178)  
24 V DC (19.2 V DC ... 28.8 V DC) 1)  
≤ 10 % 2)  
Residual ripple  
≤ 0.2 A: ≤ 0.6 Aꢀ(depending on type)  
Power consumption  
Safety outputs (OSSD)  
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 3)  
Type of output  
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)  
Switching voltage LOW ≤ 2 V DC  
Switching current ≤ 500 mA  
Diagnostic outputs  
Type of output PNP semiconductor, short-circuit protected  
Switching voltage HIGH 24 V DC (VS – 4.2 V DC ... VS)  
Switching voltage LOW High resistance  
Switching current ≤ 100 mA  
1)  
The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as  
accessories from SICK.  
2)  
Within the limits of V .  
S
3)  
Applies to the voltage range between –30 V and +30 V.  
Mechanical data  
Housing cross-section  
Housing material  
52 mm x 55.5 mm  
Aluminum alloy ALMGSI 0.5  
Powder coated  
Surface treatment  
Front screen material  
Polycarbonate, scratch-resistant coating  
Ambient data  
IP65 (EN 60529)  
Enclosure rating  
2017-08-24 18:11:25 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
3
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
–30 °C ... +55 °C  
Ambient operating temperature  
Storage temperature  
Air humidity  
A
B
C
D
E
F
–30 °C ... +70 °C  
15 % ... 95 %, Non-condensing  
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)  
10 g, 16 ms (IEC 60068-2-29)  
Vibration resistance  
Shock resistance  
Other information  
Wave length  
950 nm  
Classifications  
27272703  
27272703  
27272703  
27272703  
27272703  
27272703  
27272703  
27272703  
EC001832  
EC001832  
46171620  
ECl@ss 5.0  
ECl@ss 5.1.4  
ECl@ss 6.0  
ECl@ss 6.2  
ECl@ss 7.0  
ECl@ss 8.0  
ECl@ss 8.1  
ECl@ss 9.0  
ETIM 5.0  
H
I
ETIM 6.0  
UNSPSC 16.0901  
J
K
L
M
N
O
P
Q
R
S
T
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-08-24 18:11:25  
Subject to change without notice  
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Dimensional drawing (Dimensions in mm (inch))  
55.5 (2.19)  
52  
(2.05)  
52  
(2.05)  
27.5  
(1.08)  
M4000 Area 60  
M4000 Area 80  
14  
(0.55)  
6
(0.24)  
10.5  
(0.41)  
Sliding nut groove for  
side mounting  
Cable socket M26 with crimp contacts  
(for DIN 43651)  
2017-08-24 18:11:25 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
5
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Length of the monitored area S  
300 (11.81)  
L1  
L2  
A
B
C
D
E
F
387 (15.24)  
537 (21.14)  
687 (27.05)  
837 (32.95)  
987 (38.86)  
1,137 (44.76)  
1,287 (50.67)  
1,437 (56.57)  
1,587 (62.48)  
1,737 (68.39)  
1,887 (74.29)  
416 (16.38)  
566 (22.28)  
716 (28.19)  
866 (34.09)  
1,016 (40.00)  
1,166 (45.91)  
1,316 (51.81)  
1,466 (57.72)  
1,616 (63.62)  
1,766 (69.53)  
1,916 (75.43)  
450 (17.72)  
600 (23.62)  
750 (29.53)  
900 (35.43)  
1,050 (41.34)  
1,200 (47.24)  
1,350 (53.15)  
1,500 (59.06)  
1,650 (64.96)  
1,800 (70.87)  
Connection diagram  
M4000 Area connected to UE10-3OS safety relay  
+24 V  
H
I
S1  
+24 V  
Test  
n.c.  
n.c.  
n.c.  
n.c.  
n.c.  
EFIa  
EFIb  
n.c.  
GND  
FE  
+24 V  
RES  
1
3
1
5
EDM  
EFia  
4
6
5
9
EFib  
6
10  
3
OSSD1  
OSSD2  
n.c.  
7
8
4
1)  
11  
7
9
J
B1 B3  
Y1 13 23 33 41  
ADO  
RR  
10  
11  
2
8
GND  
FE  
UE10-3OS  
2
FE  
FE  
H2  
H3  
B2 B4  
Y2 14 24 34 42  
M4000S  
Area  
M4000R  
Area  
K
L
0 V  
E119955/00/2014-07-29  
2) PELV  
Task  
Connection of an M4000 Area multiple light beam safety device to a UE10-3OS safety relay.  
Operating mode: with restart interlock and external device monitoring.  
Operating characteristics  
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3  
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and  
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of  
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.  
If the optics are dirty, H2 indicator illuminates.  
M
N
O
P
Q
R
S
T
Fault analysis  
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the  
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does  
not enable the output current circuits.  
Comments  
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state  
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z  
path) is only possible with a single-channel control and by taking the risk analysis into account.  
2) PELV in accordance with the requirements in  
EN 60204-1 / 6.4  
Take note of the operating instructions of the integrated devices. This applies particularly to the use of configurable functions.  
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-08-24 18:11:25  
Subject to change without notice  
M40S-63A105AA0, M40E-63A105RA0 | M4000 Area  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Recommended accessories  
Other models and accessories www.sick.com/M4000_Area  
Brief description  
Type  
Part no.  
Mounting brackets and plates  
4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws  
BEF-3WNGBAST4  
7021352  
and washers  
Other mounting accessories  
2 pieces, Floor stands for the horizontal mounting of the safety light curtains C4000  
BEF-3HHOCAST2  
2041661  
Fusion, Entry/Exit, Palletizer, as well as the multi-beam safety light curtain M4000  
Area, for mounting heights of between 70 mm and 780 mm., Includes mounting  
bracket  
Terminal and alignment brackets  
4 pieces, Mounting kit 6, side bracket, rotatable, Zinc diecast  
BEF-1SHABAZN4  
BEF-2SMGEAKU4  
2019506  
2030510  
4 pieces, Mounting kit 12, rotatable, swivel mount  
Plug connectors and cables  
Head A: female connector, M26, 12-pin, straight  
Head B: cable  
Cable: PVC, unshielded, 5 m  
DOL-0612G05M075KM0 2022545  
DOL-0612G10M075KM0 2022547  
DOL-0612G20M075KM0 2022549  
DOS-0612G000GA3KM0 6020757  
Head A: female connector, M26, 12-pin, straight  
Head B: cable  
Cable: PVC, unshielded, 10 m  
Head A: female connector, M26, 12-pin, straight  
Head B: cable  
Cable: PVC, unshielded, 20 m  
Head A: female connector, M26, 12-pin, straight  
Head B: -  
Cable: unshielded  
Head A: female connector, M26, 12-pin, angled  
DOS-0612W000GA3KM0 6020758  
Head B: -  
Cable: unshielded  
Alignment aids  
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into  
the beam!  
AR60  
1015741  
4040006  
Adapter AR60 for M4000 and M4000 Curtain  
AR60 adapter, M4000  
2017-08-24 18:11:25 | Online data sheet  
Subject to change without notice  
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
7

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY