IBS1UP-CN [SILICOM]
Intelligent 1G Bypass Switch;型号: | IBS1UP-CN |
厂家: | Silicom |
描述: | Intelligent 1G Bypass Switch |
文件: | 总10页 (文件大小:450K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
IBSG
Intelligent 1G Bypass Switch
Product Description
Silicom Intelligent Bypass switch (IBSG) is an active external Bypass switch that protects network integrity from network failures
and network maintenance. The Silicom intelligent Bypass switch (IBSG) generates the heartbeat and controls the mode of
operation.
The Silicom Intelligent Bypass switch (IBSG) supports four modes of operations: Inline, Bypass, Tap and Linkdrop. In Inline mode,
the IBS diverts inline network traffic to attached in-line network system. In Bypass mode, the IBS does not diverts the traffic to the
attached in-line network system and diverts it to other network link. In Tap mode, incoming traffic in port NET0 is mirrored to port
MON0 and incoming traffic in port NET1 is mirrored to port MON1.In Linkdrop mode the IBS disables the links on the network ports
(NET0, NET1). The IBS simulates switch / router cable disconnection.
The IBS generates the heartbeat packets and transmits the heartbeat packet to the in-line Monitor / Network appliance port, the
Monitor Network appliance receives the heartbeat packets and transmits is to its other port (bridges the heartbeat packet). The IBS
detects back the heartbeat packet and maintains the Inline mode.
The IBS sets to Bypass, Tap or Linkdrop when it does not receive back the heartbeat packet from the Network / Monitor appliance.
When the Network / Monitor appliance recovers, it transmits back the heartbeat packet and the Intelligent switch sets to Inline. The
IBS bypasses its Ethernet Monitor ports on event of power failure, Link failure, in-line software application system hang or user
request.
The IBS includes Double Bypass Safe architecture. The Silicom Double Bypass safe architecture is based on two Bypass routing
circuitry: An Active Bypass circuitry and Passive Bypass circuitry. If the internal active bypass routing circuitry fails, the passive
Bypass routing circuitry is activated.
The IBS can be configured using:
•
Simple CLI configuration management via a serial communication console port, Ethernet port using Telnet or SSH
•
•
Web interface management interface
SNMP
The IBSG includes two duplex LC ports for network ports, two 2 SFP ports for the attached in-line network system, serial port (RJ-
11) and Ethernet port (RJ-45). The IBS supports Gigabit Multimode Fiber (1000Base-SX) and Gigabit single mode (1000Base-LX)
network standards.
Page 1
Silicom Ltd. Connectivity Solutions
The IBS1U is a 1U host system supports up to four intelligent bypass switches (IBS). The Bypass Switch Host can support up to
four intelligent Bypass Switch modules. The Bypass switch host includes two redundant 1 – 220 V AC power supply or two
redundant -48 DC power supply.
Figure: 1 – Front panel view of IBS
Figure: 2 – Front panel view of IBS with 4 modules
Key Features
•
Self generating heartbeat pulses – No driver or management port is required to generate pulses
Sets to Bypass when it detects in-line system failure
Sets to Bypass when it detects in-line system link failure
Sets to Bypass when it detects in-line software application system hang
Sets to Bypass on Power failure
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Sets to Normal when it detects in-line system recovery
Double Safe Bypass architecture with two routing circuitries
Two on Board Watch Dog Timer (WDT) Controllers
Software programmable time out interval
Software Programmable WDT Enable / Disable
Independent Bypass / Normal / Tap /Linkdrop operation in every module
Supports up to four modules in a chassis
Supports TAP mode of operation
Simple CLI configuration management via serial port
Telnet management interface via network management port
SSH management interface via network management port
Supports SNMP version 1, 2c, 3 (SHA, AES)
Supports remote log
Supports TACACS+
Supports NTP
Supports timezone
Supports multi configuration backup
Support Two ports link feature – if one of the network ports link fails it will drop the link on the other network port as well
Two redundant power supplies
Optional -48V DC power supplies
Page 2
Silicom Ltd. Connectivity Solutions
IBS-SX
Supports Short Range Fiber Gigabit Ethernet (1000Base-SX)
•
IBS-LX
Supports Short Range Fiber Gigabit Ethernet (1000Base-LX)
•
IBSG-ZX
Supports Long Range Fiber Gigabit Ethernet (1000Base-ZX)
•
Technical Specifications
Bypass Specifications
Routing
Transmit heart beat packet every 3mS – 10Sec. Default 5mS
Verification packets received every 10mS – 50Sec. Default 20mSec
Double Bypass
WDT Interval (Software
Programmable)
Transmit heart beat packet every 300mS – 60Sec. Default 7Sec
Verification packets received every 1S – 253Sec. Default 20Sec
Production Default configuration
Mode at Power up
Bypass
Heartbeat
Activated
Bypass Switch is ready and in-
line device responds to
heartbeat
Change to Normal
In-line device responds to
heartbeat
Normal
Bypass
In-line device does not
respond heartbeat
Mode at Power 0ff
Heartbeat Packet
Bypass
Internetwork Packet Exchange
IBS1U: Bypass Switch 1U Host System
Dockings
Front holders
Page 3
Silicom Ltd. Connectivity Solutions
AC: 90-240 VAC Auto-Select
Voltage Input
Power Consumption
Size
-48 (-75 – -36) VDC
160W maximum – When 4 IBS modules are installed
444mm x 339.3mm x 44 mm ( 17.48” x 13.358” x 1.732”)
Wide x Depth X Height
Operating Humidity
Operating Temperature
Storage Temperature
EMC Certifications
MTBF*
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B FCC / CE / VCCI
> 150,000 hours
IBS1U: Bypass Switch 1U Host System LEDs / Connector Specifications
LEDs:
(2) Power LED – Green, Power is on, LED per power supply
IBS -SX – Fiber Gigabit Ethernet Technical Specifications – (1000Base-SX) Adapters
IEEE Standard / Network
Fiber Gigabit Ethernet, 1000Base-SX (850nM)
topology
Data Transfer Rate
2Gbit/s in full duplex mode per port
Multimode fiber:62.5um
Cables and Operating distance 137m maximum at 62.5 um **
Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard
Insertion Loss ( Passive:
Normal Mode)
Typical: 0.8 dB
Maximum: 1.9 dB
Insertion Loss ( Passive:
Normal Mode)
Typical: 0.8 dB
Maximum: 1.9 dB
Voltage
Size
12V +/-5%
173.3mm x 164.9mm x 20 mm ( 6.822” x 6.73” x 0.787”) Wide x Depth X Height
Operating Humidity
0%–90%, non-condensing
Page 4
Silicom Ltd. Connectivity Solutions
Operating Temperature
Storage Temperature
EMC Certifications
MTBF*
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B / FCC / CE / VCCI
> 150,000 hours
IBS-SX: LED and Connector Specifications
Network / Monitor ports:
Link LED – (Green) On Link partner is detected.
Activity LED – (Yellow) Blinks on activity.
Power – Green power is on
Normal – Green, Switch in Normal mode.
SysOK – Yellow when Sys is OK,
WDT – Blink Yellow when WDT is activated
Light Yellow WDT time out
LEDs:
Off: WDT is disabled
Bypass – Red when bypass, off on Normal
Alarm – Red on system alarm
Network: 2 LC Duplex
Monitor: 2 SFP
Connectors
Management
RJ-11 serial port
RJ-45 Ethernet // optional for future use
IBS-LX – Fiber Gigabit Ethernet Technical Specifications – (1000Base-LX) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 1000Base-LX (1310nM)
topology
Data Transfer Rate
2Gbit/s in full duplex mode per port
Network ports Cables and
Operating distance
Single mode fiber:
5000m maximum at 9 um **
Insertion Loss ( Passive:
Normal Mode)
Typical: 1.2 dB
Maximum: 1.6dB
Insertion Loss ( Passive:
Bypass Mode)
Typical: 1.2 dB
Maximum: 1.6dB
Page 5
Silicom Ltd. Connectivity Solutions
Voltage
12V +/-5%
Size
173.3mm x 164.9mm x 20 mm ( 6.822” x 6.73” x 0.787”)
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B FCC / CE / VCCI
UL
Operating Humidity
Operating Temperature
Storage Temperature
EMC Certifications
Safety
MTBF*
> 150,000 hours
IBS-LX: LED and Connector Specifications
Network / Monitor ports:
Link LED – (Green) On Link partner is detected.
Activity LED – (Yellow) Blinks on activity.
Power – Green power is on
Normal – Green, Switch in Normal mode.
SysOK – Yellow when Sys is OK,
WDT – Blink Yellow when WDT is activated
Light Yellow WDT time out
LEDs
Off: WDT is disabled
Bypass – Red when bypass, off on Normal
Alarm – Red on system alarm
Network: 2 LC Duplex
Monitor: 2 SFP
Connectors
Management
RJ-11 serial port
RJ-45 Ethernet // optional for future use
Fiber Gigabit Ethernet Technical Specifications – (1000Base-ZX) Adapters:
IEEE Standard / Network
Fiber Gigabit Ethernet, 1000Base-ZX (1550nM)
topology:
Data Transfer Rate:
2Gbit/s in full duplex mode per port
Single mode fiber:9/125um
35Km maximum at 9 um **
Cables and Operating
Page 6
Silicom Ltd. Connectivity Solutions
distance:
Voltage:
Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3 standard
12V +/-5%
173.3mm x 164.9mm x 20 mm ( 6.822” x 6.73” x 0.787”)
Size:
Wide x Depth X Height
Operating Humidity:
Operating Temperature:
Storage Temperature:
EMC Certifications:
MTBF*:
0%–90%, non-condensing
0°C – 40°C (32°F – 104°F)
-20°C–65°C (-4°F–149°F)
Class B / FCC / CE / VCCI
> 150,000 hours
IBSG-ZX: LED and Connector Specifications
Network / Monitor ports:
Link LED – (Green) On Link partner is detected.
Activity LED – (Yellow) Blinks on activity.
Power – Green power is on
Normal – Green, Switch in Normal mode.
SysOK – Yellow when Sys is OK,
WDT – Blink Yellow when WDT is activated
Light Yellow WDT time out
LEDs:
Off: WDT is disabled
Bypass – Red when bypass, off on Normal
Alarm – Red on system alarm
Network: 2 LC Duplex
Monitor: 2 SFP 1000BaseLX
Management
Connectors:
RJ-11 serial port
RJ-45 Ethernet // optional for future use
Description
Figure: 3 – Normal Mode Functional Block Diagram
Page 7
Silicom Ltd. Connectivity Solutions
Figure: 4 – Bypass Mode Functional Block Diagram
Figure: 5 – Tap Mode Functional Block Diagram
Page 8
Silicom Ltd. Connectivity Solutions
Figure: 6 – Linkdrop Mode Functional Block Diagram
Order Information
IBS
System Format
Media
Media Type
Power Cord
-R
-US
-EU
-CN
-48
IBSGP:
SX: Multimode
Intelligent
Bypass Switch
1U: 1U
G: 1Gb
ROHS
LX: Single mode
P/N
Description
Notes
IBSGP-SX
Gigabit Fiber (SX) Intelligent Bypass Switch
Gigabit Fiber (LX) Intelligent Bypass Switch
Multimode, module only
Singlemode, module only
IBSGP-LX
Singlemode, module only, ZX on the network
ports, LX on the Monitor ports
IBSGP-ZXLX
Gigabit Fiber (ZX) Intelligent Bypass Switch
Stand alone Gigabit Fiber (SX) Intelligent Bypass
Switch
IBSSGP-SX-US
IBSSGP-LX-EU
Multimode, stand alone, 110V cable
Single mode, stand alone, 220V cable
Stand alone Gigabit Fiber (LX) Intelligent Bypass
Switch
Stand alone Gigabit Fiber (ZX) Intelligent Bypass
Switch
ZX on the network ports, LX on the Monitor ports
, Single mode, stand alone, 220V cable
IBSSGP-ZXLX-EU
RK-1U-2-IBSS
Page 9
1U Rack Mount Kit for two IBSS products
Silicom Ltd. Connectivity Solutions
1U host system,(90-240 VAC Auto-Select), US
cable
IBS1UP-US
IBS1UP-EU
IBS1UP-CN
Intelligent Bypass Switch 1U host system
Intelligent Bypass Switch 1U host system
1U host system,(90-240 VAC Auto-Select), EU
cable
1U host system,(90-240 VAC Auto-Select), CN
cable
Intelligent Bypass Switch 1U host system
Intelligent Bypass Switch 1U host system
IBS1UP-48
1U host system,(-75 – -36) VDC
IBSG1UP-1SX-EU
IBSG1UP-1LX-EU
1U w/ Gigabit Fiber (SX) Intelligent Bypass Switch Multimode, 1U host, EU cable
1U w/ Gigabit Fiber (LX) Intelligent Bypass Switch Single mode, 1U host, EU cable
Single mode, 1U host, -48V redundant power
IBSG1UP-1LX-48
1U w/ Gigabit Fiber (LX) Intelligent Bypass Switch
1U w/ Gigabit Fiber (ZX) Intelligent Bypass Switch
supply
ZX on the network ports, LX on the Monitor
ports, 1U host, US cable
IBSG1UP-1ZXLX-US
IBSG1UP-2SX-CN-R
IBSG1UP-2LX-48
1U w/ Two Gigabit (SX) Intelligent Bypass Switch. 2 x Multimode, 1U host, CN cable
2 x Single mode, 1U host, -48V redundant power
supply
1U w/ Gigabit Fiber (LX) Intelligent Bypass Switch
1U w/ Two Gigabit Intelligent Bypass Switch. One 1 x Single mode, 1x Multimode, 1U host, EU
(LX) and one (SX) cable
IBSG1UP-1LX-1SX-EU
Note: Model P/N
–US: Includes US power cable (90-240 VAC Auto-Select)
-EU: Includes EU power cable (90-240 VAC Auto-Select)
-CN: Includes CN power cable (90-240 VAC Auto-Select)
-48: (-75 – -36) VDC
2V3
Page 10
Silicom Ltd. Connectivity Solutions
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明