GPC130 Commercial/GPM130 Medical  
130 Watt Global Performance Switchers  
FEATURES:  
Wide-range ac input 85-264 Vac  
2-year warranty  
Commercial Approved to UL1950, IEC950,  
EN60950 and CSA22.2-234 L3  
Medical Approved to UL2601-1, IEC601-1 and  
CSA22.2 No. 601  
Conducted EMI exceeds FCC Class B and CISPR 22  
Class B (Commercial models) and CISPR 11 Class B  
(Medical models)  
marked to LVD  
Power Fail  
SPECIFICATIONS:  
TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms  
before output voltage drops more than 4% below nominal  
voltage upon loss of ac power.The signal is factory set to  
trip on 84 to 94Vac brown-out depending upon incoming line  
impedance and distortion. Other settings are available to the  
user through adjustment of built-in potentiometer.  
Ac Input  
85-264 Vac, 47-63 Hz single phase.  
Input Current  
Maximum input current at 120Vac, 60 Hz with full rated output  
load: 3.5 A  
Output Noise  
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.  
Measured with noise probe directly across output terminals of  
the power supply.  
Hold-UpTime  
20 ms minimum from loss of ac input at full load, nominal line  
(115Vac).  
Transient Response  
Output Power  
100 W continuous, 165W peak;130W with 26 cfm air flow.Peak  
ratings are for 60 s maximum duration, 10% duty cycle. During  
peak load condition, output regulation may exceed total  
regulation limits.  
Main output500µSec typical response time for return to within  
0.5% of final value for a 50% load step change. i/t<0.2 A/µs.  
Maximum voltage deviation is 3.5%. Startup/shutdown overshoot  
less than 3%.  
Overload Protection  
Remote Sense  
Provided as a standard feature on output 1.  
Fully protected against short circuit and output overload. Short  
circuit protection is cycling type power limit on outputs 1 & 2;  
foldback type on outputs 3 & 4. Recovery after fault is automatic.  
See output ratings chart for additional notes or conditions.  
Voltage Adjustment  
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.  
Overvoltage Protection  
Main outputs: 124% ± 12% typical.  
Overload Protection  
Factory set to begin power limiting at approximately 170W.  
Efficiency  
EMI/EMC Compliance  
70% at full rated load, nominal input voltage, depending on model  
and load distribution.  
All models include built-in EMI filtering to meet the following  
emissions requirements:  
EMI SPECIFICATIONS  
COMPLIANCE LEVEL  
Turn-onTime  
Conducted Emissions GPC130 EN55022 Class B; FCC Class B  
Conducted Emissions GPM130 EN55022 Class B; FCC Class B  
Less than 1 second at 120Vac, 25°C (inversely proportional to  
input voltage and thermistor temperature).  
Static Discharge  
EN61000-4-2, 6 kV contact, 8 kV air  
EN61000-4-3, 3 V/meter  
RF Field Susceptibility  
Fast Transients/Bursts  
Surge Susceptibility  
Input Protection  
Internal ac fuse provided. Designed to blow only if a catastrophic  
failure occurs in the unit.  
EN61000-4-4, 2 kV, 5 kHz  
EN61000-4-5, 1 kV diff., 2 kV com.  
Commercial Leakage Current  
0.7 mA 254 Vac @ 60 Hz input.  
Inrush Current  
Inrush is limited by internal thermistors.Inrush at 240Vac under  
cold start conditions will not exceed 34 A.  
Commercial Safety  
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and  
EN60950. UL file #E135803 commercial; CSA #LR46516 all  
models.The output(s) are intended for safety earthed Signal  
Output and Intermediate Circuits only. All dc outputs are SELV  
under normal and single fault conditions.  
Temperature Coefficient  
0.03%/°C typical on all outputs.  
Thermal Shutdown  
Provided as a standard feature. Designed to protect unit from  
prolonged overtemperature.  
Medical Leakage Current  
35 µA 254 Vac @ 60 Hz input.  
Environmental  
Medical Safety  
Designed for 0 to 50°C operation at full rated output power;  
derate output current and total output power by 2.5% per °C  
above 50°C. See Environmental and Packaging Specifications  
on next page.  
Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL  
file E116994;CSA #LR46516.The output(s) are intended for  
safety earthed Signal Output and Intermediate Circuits only.The  
output(s) are not acceptable for patient connection without  
additional isolation.All dc outputs are SELV under normal and  
single fault conditions.  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com  
54  
GPC130 Commercial/GPM130 Medical 130 Watt Multiple Output  
Commercial  
Model  
Medical  
Model  
Output  
Minimum  
Output  
Maximum (B)  
Output  
Total  
Output No.  
Output  
Maximum (C) Output Peak  
Noise P-P Regulation (A)  
GPC130A  
GPC130B  
GPC130C  
GPC130D  
GPC130E  
GPM130A  
GPM130B  
GPM130C  
GPM130D  
GPM130E  
1
2
3
4
+5 V  
+12 V  
-12 V  
+12 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
120 mV  
120 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+ 5 V  
+12 V  
-5 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
50 mV  
2%  
2%  
3%  
3%  
-12 V  
120 mV  
1
2
3
4
+5 V  
+12 V  
-15 V  
+15 V  
3 A  
0 A  
0 A  
0 A  
16 A  
5 A  
1.2 A  
1.2 A  
20 A  
5 A  
1.2 A  
1.2 A  
25 A  
8 A  
1.5 A  
1.5 A  
50 mV  
120 mV  
150 mV  
150 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5 V  
+24 V  
-12 V  
+12 V  
3 A  
0 A  
0 A  
0 A  
16 A  
3.5 A  
1.2 A  
1.2 A  
20 A  
3.5 A  
1.2 A  
1.2 A  
25 A  
5 A  
1.5 A  
1.5 A  
50 mV  
240 mV  
120 mV  
120 mV  
2%  
2%  
3%  
3%  
1
2
3
4
+5 V  
+24 V  
-15 V  
+15 V  
3 A  
0 A  
0 A  
0 A  
16 A  
3.5 A  
1.2 A  
1.2 A  
20 A  
3.5 A  
1.2 A  
1.2 A  
25 A  
5 A  
1.5 A  
1.5 A  
50 mV  
240 mV  
150 mV  
150 mV  
2%  
2%  
3%  
3%  
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.  
B. Unrestrictednaturalconvectioncooling.  
C. Requires26 cfmmovingair.  
GPC130/GPM130 MECHANICAL SPECIFICATIONS  
Environmental  
Specification  
Operating  
Non-operating  
Temperature (A)  
See individual specs  
0 to 95% RH  
-40 to +85oC  
0 to 95% RH  
40 gpk  
Humidity (A)  
Shock (B)  
Altitude  
A. Units should be allowed to warm up/operate under non-condensing conditions  
before application of power.  
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3  
orthogonal axes.Tested for 10 min./axis operating and 1 hr./axis non-operating.  
C. Shock testinghalf-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,  
total 6 shocks.  
20 gpk  
-500 to 10,000 ft  
1.5 grms, 0.003 g2/Hz  
-500 to 40,000 ft  
5 grms, 0.026 g2/Hz  
Vibration (C)  
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033  
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com  
55  

相关型号:

GPC130A1

Power Supply Module
SLPOWER

GPC130A3

Power Supply Module
SLPOWER

GPC130A4

Power Supply Module
SLPOWER

GPC130B

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130B1

Power Supply Module
SLPOWER

GPC130B4

Power Supply Module
SLPOWER

GPC130BG

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130C

AC-DC Regulated Power Supply Module, 130W
SLPOWER

GPC130C1

Power Supply Module
SLPOWER

GPC130C2

Power Supply Module
SLPOWER

GPC130C3

Power Supply Module
SLPOWER

GPC130CG

AC-DC Regulated Power Supply Module, 130W
SLPOWER