TE90A2403N01 [SLPOWER]

90W Single Output External Power;
TE90A2403N01
型号: TE90A2403N01
厂家: SL Power Electronics    SL Power Electronics
描述:

90W Single Output External Power

文件: 总5页 (文件大小:872K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TE90  
90W Single Output External Power  
Test & Measurement/Industrial Series  
Features  
.
Meets DoE Efficiency Level VI Requirements  
.
.
No load input power  
Average Efficiency  
.
.
.
.
Up to 90W of AC-DC Power  
Universal Input 90-264Vac Input Range  
IP22 Rated Enclosure  
Meets “Heavy Industrial” Levels of EN61000  
EMC Requirements  
.
.
Meets EN55011/CISPR11, FCC Part 15.109  
Class B Conducted & Radiated Emissions, with  
6db margin  
Approved to EN/IEC/UL60950-1, 2nd Edition,  
Am. 2  
.
.
.
E-cap life of >7 years  
3 Year Warranty  
RoHS/REACH Compliant  
Description  
A high performance AC to DC external power supply family designed for test & measurement and industrial applications.  
Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial  
levels of various EN61000-4-x standards for EMC. The TE90 series models also meet Class B conducted and radiated  
EMI per FCC Part 15, EN55022, CISPR22, with margin. Designed to allow easy integration with test and measurement  
equipment and other industrial applications.  
Model Selection  
Model  
Number  
Output  
Current  
7.50A  
Output  
Power  
90W  
Ripple &  
Noise¹  
120mV pk-pk  
Line  
Regulation  
±1%  
Load  
Regulation  
±5%  
Output Cable  
& Connector  
Input  
Configuration  
Volts  
12.0V  
15.0V  
18.0V  
24.0V  
12.0V  
15.0V  
18.0V  
24.0V  
12.0V  
15.0V  
18.0V  
24.0V  
TE90A1251F01  
6 pin Molex Type2  
Class I Desktop,  
IEC60320 C14  
Receptacle  
TE90A1503F01  
TE90A1803F01  
TE90A2403F01  
TE90A1251N01  
TE90A1503N01  
TE90A1803N01  
TE90A2403N01  
TE90A1251Q01  
TE90A1503Q01  
TE90A1803Q01  
TE90A2403Q01  
6.00A  
5.00A  
3.75A  
7.50A  
6.00A  
5.00A  
3.75A  
7.50A  
6.00A  
5.00A  
3.75A  
90W  
90W  
90W  
90W  
90W  
90W  
90W  
90W  
90W  
90W  
90W  
150mV pk-pk  
180mV pk-pk  
240mV pk-pk  
120mV pk-pk  
150mV pk-pk  
180mV pk-pk  
240mV pk-pk  
120mV pk-pk  
150mV pk-pk  
180mV pk-pk  
240mV pk-pk  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±1%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
2.5 x 5.5 x 9.5mm  
Straight Barrel Type,  
center positive  
6 pin Molex Type2  
Class II Desktop,  
IEC60320 C8  
Receptacle  
2.5 x 5.5 x 9.5mm  
Straight Barrel Type,  
center positive  
6 pin Molex Type2  
Class II Desktop,  
IEC60320 C18  
Receptacle  
2.5 x 5.5 x 9.5mm  
Straight Barrel Type,  
center positive  
Notes:  
1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors.  
2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information.  
3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE90B1251F01).  
4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted.  
www.slpower.com  
TE90 Rev 2.1 25-APR-16  
1
TE90  
90W Single Output External Power  
Test & Measurement/Industrial Series  
General Specifications  
Less than 1 sec @115Vac, full load  
20mS min., at full Load, 100Vac input  
AC Input 100-240Vac, ±10%, 47-63Hz, 1∅  
Turn On Time  
Hold-up Time  
115Vac: 1.2A, 230Vac: 0.6A  
Input Current  
Inrush Current  
Input Fuses  
Overtemperature  
Protection  
Will shutdown upon an over-temperature  
condition, auto-recovery.  
264Vac, cold start: will not exceed 60A  
F1, F2: 5A, 250Vac fuses (line & neutral lines)  
provided on all models  
130 to 180% of rating, Hiccup Mode  
Hiccup Mode, auto recovery.  
Overload Protection  
Earth Leakage  
Current  
Short Circuit  
Protection  
Input-GND: <500μA@264Vac, 60Hz, NC  
Output-GND: <4mA@264Vac, 60Hz, NC  
Overvoltage  
Protection  
Meets US DoE Efficiency Level VI average  
efficiency levels  
130 to 150% of output voltage (max. 60V on  
48V model), hiccup mode  
Efficiency  
Input-Output: 4000Vac  
Input-Ground: 1500Vac  
Output-Ground: 1500Vac  
90W continuous – See models chart for  
specific voltage model ratings.  
Output Power  
Isolation  
No Load Input  
Power  
<0.210W per DoE Efficiency Level VI  
Requirements  
EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2  
Safety Standards  
Operating  
Temperature  
See models chart on pg 1.  
Ripple and Noise  
Output Voltage  
-20°C to +70°C. Derate above 40°C.  
Case Temperatures are within regulatory  
guidelines. Care should be taken to avoid  
prolonged contact with skin or other heat  
sensitive surfaces.  
See models chart on pg 1.  
Case Temperature  
500µs response time for return to within 0.5%  
Transient of final value for any 50% load step over the  
Response  
Temperature  
Derating  
See Derating Chart  
range of 5% to 100% of rated load, i/t<  
0.2A/µs. Max. voltage deviation is +/-3.5%.  
>7 year life based on calculations at  
>500,000 hours, full load, 110 & 220Vac  
input, 25°C amb., per Telcordia 332 Issue 6.  
115Vac/60Hz & 230Vac/50Hz, ambient 25°C  
at 24 hrs per day, 365 days/year, 6 power up  
cycles per day. (80% load on 12V model)  
E-Cap Life  
MTBF  
600g  
-40°C to +85°C  
Weight  
Safety Drop Test  
Dimensions  
Storage Temperature  
Altitude  
Operating: to 5000m (derate to TBD temp.  
above 3000m).  
Non-operating: -500 to 40,000 ft.  
1.4m from table top to wooden platform, 6  
faces.  
W: 2.58” x L: 5.9” x H: 1.34”  
W: 65.5mm x L: 150.5mm x H: 34mm  
5% to 95%, non-condensing  
Relative Humidity  
Operating: 0.003g/Hz, 1.5grms overall, 3  
axes, 10 min/axis, 1-500Hz.  
Operating: Half-sine, 20gpk, 10mS, 3 axes,  
6 shocks total  
Non-Operating: Half-sine waveform, impact  
acceleration of 100G, Pulse duration of 6  
mS, Number of shocks: 3 for each of the  
three axis  
Non-Oper.: random waveform, 3 minutes per  
axis, 3 axes and Sine waveform, Vib.  
frequency/acceleration: 10-500Hz/1g, sweep  
rate of 1 octave / minutes, Vibration time of 10  
sweeps / axes, 3 axes  
Vibration  
Shock  
All specifications are typical at nominal input, full load, at 25°C ambient unless noted.  
www.slpower.com  
TE90 Rev 2.1 25-APR-16  
2
TE90  
90W Single Output External Power  
Test & Measurement/Industrial Series  
EMI/EMC Compliance  
EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac  
EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac  
High Frequency (100kHz-20MHz): <40mA pk-pk  
Conducted Emissions:  
Radiated Emissions:  
Common Mode Noise:  
Electro-Static Discharge (ESD)  
Immunity on Power ports:  
EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A  
EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz  
Radiated RF EM Fields Susceptibility  
Electrical Fast Transients (EFT) /Bursts:  
EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A  
EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A  
Surges, Line to Line (Diff Mode) and Line  
to GND (CMN Mode)  
Conducted Disturbances induced by RF  
Fields  
EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz  
and 80Mhz, 80% AM at 1KHz  
EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz  
Rated Power frequency magnetic fields  
EN55024/IECEN61000-4-11:  
--100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20mS at 0 degrees.  
Criteria A  
--100% dip for 5000mS (250/300 cycles), Criteria B  
--60% dip for 100mS, Criteria B  
Voltage Interruptions, Dips, Sags &  
Surges  
--30% dip for 500mS, Criteria A  
EN55011/EN61000-3-2, Class A  
EN61000-3-3  
Harmonic Current Emissions  
Flicker Test  
Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following:  
A – Normal performance during and after the test  
B – Temporary degradation, self-recoverable  
C – Temporary degradation, operator intervention required to recover the operation  
D – Permanent damage  
Derating Chart:  
ͦ  
www.slpower.com  
TE90 Rev 2.1 25-APR-16  
3
TE90  
90W Single Output External Power  
Test & Measurement/Industrial Series  
Mechanical Drawing:  
34±0.5  
65.5±0.5  
65.5±0.5  
34±0.5  
15V through 24V Models: 2.5 x 5.5 x 9.5mm  
Barrel Connector, center positive.  
1) All dimensions in mm.  
2) The unit should not be covered or enclosed to protect against excessive case temperature rise.  
12V Models: Output Connector: 6 pin Molex 39-01-2060  
or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC  
Notes:  
Connector Information  
Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. (#51 for the 12V models). Other  
standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below:  
www.slpower.com  
TE90 Rev 2.1 25-APR-16  
4
TE90  
90W Single Output External Power  
Test & Measurement/Industrial Series  
Efficiency Level VI Information:  
TE90A Series  
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for  
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.  
www.slpower.com  
TE90 Rev 2.1 25-APR-16  
5

相关型号:

TE90A2403Q01

90W Single Output External Power
SLPOWER

TEA-566A

POWER MOSFET
NEC

TEA0652

MONOLITHISCHE STEREO IS
ETC

TEA0653T

Dolby Noise Reduction IC, PDSO20
PHILIPS

TEA0653TD

Dolby Noise Reduction IC, PDSO20
PHILIPS

TEA0654

MONOLITHISCHE STEREO IS
ETC

TEA0665

IC B AND C Type, DOLBY NOISE REDUCTION IC, PDIP28, 0.600 INCH, PLASTIC, SOT-117-1, DIP-28, Noise Suppression IC
NXP

TEA0665T

IC B AND C Type, DOLBY NOISE REDUCTION IC, PDSO28, 7.50 MM, PLASTIC, SOT-136A-1, SOP-28, Noise Suppression IC
NXP

TEA0675

Dual Dolby* B-type noise reduction circuit for playback applications
NXP

TEA0675T

Dual Dolby* B-type noise reduction circuit for playback applications
NXP