C-13-2500C-TDFB-SSC2 [SOURCE]

2.5 Gbps Single Mode Transceiver; 2.5 Gbps的单模收发器
C-13-2500C-TDFB-SSC2
型号: C-13-2500C-TDFB-SSC2
厂家: SOURCE PHOTONICS, INC.    SOURCE PHOTONICS, INC.
描述:

2.5 Gbps Single Mode Transceiver
2.5 Gbps的单模收发器

光纤 通信
文件: 总6页 (文件大小:1898K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Features  
• SC Duplex Single Mode Transceiver  
• Industry Standard 1x9 Footprint  
• Complies with SONET OC-48 STM-16  
• Single +3.3V / +5V Power Supply  
• Operating Temperature Range 0~ +70℃  
• CML Differential Data Inputs and Outputs  
• PECL/LVPECL Signal Detection Output  
[C-1X-2500-TDFB(3)-SSCX]  
• TTL/LVTTL Signal Detection Output  
[C-1X-2500C-TDFB(3)-SSCX]  
• Wave Solderable and Aqueous Washable  
• Uncooled laser diode with MQW structure  
• Complies with Telcordia (Bellcore) GR-468-CORE  
Applications  
• STM 16/ OC-48, 2.5 Gigabit  
Absolute Maximum Rating  
Parameter  
Symbol  
Vcc  
Min.  
Max.  
3.6  
6
Unit  
V
Note  
Power Supply Voltage  
Power Supply Voltage  
Output Current  
0
0
C-1X-2500(C)-TDFB3-SSCX  
C-1X-2500(C)-TDFB-SSCX  
Vcc  
V
Iout  
0
30  
mA  
ºC  
ºC  
ºC  
Soldering Temperature  
Operating Temperature  
Storage Temperature  
-
260  
70  
10 seconds on leads only  
-
Topr  
Tstg  
0
-40  
85  
Recommended Operating Condition  
Parameter  
Symbol  
Min.  
3.1  
4.75  
0
Typ.  
Max.  
3.5  
5.25  
70  
Unit  
V
Power Supply Voltage 1  
Power Supply Voltage 1  
Operating Temperature (Case)  
Data Rate  
Vcc  
Vcc  
Topr  
-
3.3  
5
V
-
ºC  
-
2488.32  
-
Mbit/s  
Note1: Please refer to ordering information  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
1
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Transmitter Specifications (Optical)  
Parameter  
Symbol  
Min  
-5  
Typical  
Max  
Unit  
dBm  
dBm  
nm  
Notes  
C-1X-2500(C)-TDFB(3)-SSC2  
C-1X-2500(C)-TDFB(3)-SSC4  
C-13-2500(C)-TDFB(3)-SSCX  
C-15-2500(C)-TDFB(3)-SSCX  
-20 dB width  
Po  
Po  
-
0
+5  
1355  
1580  
1
Optical Transmit Power  
Optical Transmit Power  
Output center Wavelength  
Output center Wavelength  
Output Spectrum Width  
Side Mode Suppression Ratio  
Extinction Ratio  
0
-
1310  
1550  
-
λ
1280  
1500  
-
λ
nm  
λ  
SMSR  
ER  
nm  
30  
35  
-
dB  
CW, Po=5mW  
8.2  
-
-
dB  
Output Eye  
Compliant with ITU recommendation G.957  
Relative Intensity Noise  
Total Jitter  
RIN  
TJ  
-
-
-
-
-120  
0.18  
dB/Hz  
ns  
Measured with 223-1 PRBS with 72 ones and  
72 zeros  
Transmitter Specifications (Electrical)  
Parameter  
Symbol  
ICC  
IIL  
Min  
Typical  
Max  
Unit  
Notes  
Maximum current is specified at  
Vcc= Maximum @ maximum temperature  
-
-
260  
mA  
Power Supply Current  
Data Input Current-Low  
Data Input Current-High  
Data Input Voltage  
-350  
-
-
-
-
-
350  
-
µA  
µA  
mV  
I
IH  
V -VIL  
IH  
300  
Peak-peak, single ended, AC coupled  
Receiver Specifications (Optical)  
Parameter  
Sensitivity2  
Symbol  
Min  
Typical  
Max  
-20  
-
Unit  
dBm  
dBm  
dBm  
dBm  
dB  
Notes  
-
-
0
-
-
-
-
-
-
Maximum Input Power  
Signal Detect-Asserted  
Signal Detect-Deasserted  
Signal Detect-Hysteresis  
Wavelength of Operation  
Reflectance  
Pin  
Pa  
Pd  
-
-20  
-
Measured on transition: low to high  
Measured on transition: high to low  
-38  
1
-
1100  
1600  
-27  
nm  
dB  
-10  
Note 2: Measured with 223-1 PRBS, BER= 10  
Receiver Specifications (Electrical)  
Parameter  
Symbol  
Min  
-
Typical  
Max  
100  
900  
0.5  
-
Unit  
mA  
mV  
V
Note  
ICC  
VOH -VOL  
VSDL  
-
-
-
-
The current excludes the output load current  
Peak-peak, single-ended, AC-coupled  
Power Supply Current  
Data output Voltage  
300  
-
Signal Detect Output Voltage-Low  
Signal Detect Output Voltage-High  
C-1X-2500C-TDFB(3)-SSCX  
C-1X-2500-TDFB(3)-SSCX  
2.0  
V
VSDH  
Signal Detect Output Voltage-Low VSDL-Vcc  
Signal Detect Output Voltage-High Vcc  
-2.0  
-1.1  
-
-
-1.58  
-0.74  
V
V
VSDH-  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
2
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Connection Diagram  
Receiver Signal Ground  
Receiver Data Out  
1. (Rx GND)  
2. (Rx +)  
3. (Rx-)  
NC  
Receiver Data Out Bar  
Signal Detect  
4. (SD)  
Receiver Power Supply  
Transmitter Power Supply  
Transmitter Data In Bar  
Transmitter Data in  
5. (Rx Vcc)  
6. (Tx Vcc)  
7. (TX-)  
8. (TX+)  
9. (Tx GND)  
Top View  
NC  
Transmitter Signal Ground  
PIN  
Symbol  
RxGND  
RD+  
Notes  
Directly connect this pin to the receiver ground plane  
See recommended circuit schematic  
1
2
3
4
5
6
7
RD-  
See recommended circuit schematic  
SD  
Active high on this indicates a received optical signal  
DC power for the receiver section  
RxVcc  
TxVcc  
TD-  
DC power for the transmitter section  
See recommended circuit schematic  
8
TD+  
See recommended circuit schematic  
9
TxGND  
Directly connect this pin to the transmitter ground plane  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
3
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Recommended Circuit Schematic  
C-1X-2500-TDFB(3)-SSCX  
Rx Vcc  
9 8 7 6 5 4 3 2  
1
C5  
R1  
RD +  
TD +  
TD -  
Z=50  
!
!
Z=50  
!
!
Z=50  
Z=50  
RD -  
SD  
Tx Vcc  
Rx Vcc  
R2  
No internal  
connection  
No internal  
connection  
Transceiver  
Top view  
L1  
Rx Vcc  
C3  
L2  
C1  
C2  
Vcc  
Notes +3.3V:  
C1=C2=C5=0.1"F  
C3=C4=10"F  
L1=L2=1"H  
R1=130!  
Notes +5V:  
C1=C2=C5=0.1"F  
C3=C4=10"F  
L1=L2=1"H  
R1=82!  
Tx Vcc  
C4  
R2=82!  
R2=130!  
C-1X-2500C-TDFB(3)-SSCX  
9
8
7
6
5
4
3
2
1
RD +  
TD +  
TD -  
Z=50!  
Z=50!  
Z=50!  
Z=50!  
RD -  
SD  
Tx Vcc  
Rx Vcc  
No internal  
connection  
No internal  
connection  
Transceiver  
Top view  
L1  
Rx Vcc  
Tx Vcc  
Notes:  
C3  
L2  
C1  
C2  
C1=C2=0.1"F  
C3=C4=10"F  
L1=L2=1"H  
Vcc  
C4  
The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals.  
The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc.  
A GND plane under the module is required for good EMI and sensitivity performance.  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
4
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Package Diagram  
SC Transceiver Assembly 9.8mm  
Units in mm  
Front View  
Top View  
Rear View  
Side View  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
5
2.5 Gbps Single Mode Transceiver  
C-1X-2500(C)-TDFB(3)-SSCX  
Ordering Information  
Available Options:  
C-13-2500-TDFB-SSC4  
C-13-2500-TDFB-SSC2  
C-13-2500C-TDFB-SSC2  
C-13-2500-TDFB3-SSC2  
C-13-2500C-TDFB3-SSC2  
C-15-2500-TDFB-SSC2  
C-15-2500C-TDFB-SSC2  
C-15-2500-TDFB3-SSC2  
C-15-2500C-TDFB3-SSC2  
C-13-2500C-TDFB-SSC4  
C-13-2500-TDFB3-SSC4  
C-13-2500C-TDFB3-SSC4  
C-15-2500-TDFB-SSC4  
C-15-2500C-TDFB-SSC4  
C-15-2500-TDFB3-SSC4  
C-15-2500C-TDFB3-SSC4  
Part numbering Definition:  
C - 1X - 2500(C) - TDFB(3) - S SC TxPower  
• 13 = Wavelength 1310nm  
15 = Wavelength 1550nm  
• Communication protocol  
(2.5 Gbps)  
2500 = PECL Signal Detection Output  
2500C = TTL Signal Detection Output  
• TDFB = +5V Transceiver, DFB  
TDFB3= +3.3V Transceier, DFB  
• Single mode fiber  
• Connector options  
• Tx Power range  
2 = -5 to 0 dBm  
4 = 0 to +5 dBm  
Warnings:  
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow  
guidelines according to proper ESD procedures.  
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.  
Legal Notes:  
IMPORTANT NOTICE!  
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance  
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are  
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-  
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of  
Sale for further warranty information.  
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual  
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes  
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-  
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers  
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from  
such use or sale.  
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any  
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact  
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.  
© LuminentOIC, Inc. 2003  
All rights reserved  
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486  
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213  
LUMINENTOIC.COM  
LUMNDS797-Dec0904  
rev. A.0  
6

相关型号:

C-13-2500C-TDFB-SSC4

2.5 Gbps Single Mode Transceiver
SOURCE

C-13-2500C-TDFB3-SSC2

2.5 Gbps Single Mode Transceiver
SOURCE

C-13-2500C-TDFB3-SSC4

2.5 Gbps Single Mode Transceiver
SOURCE

C-13-622-F-SLC

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLC-55-G5

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLC-G5

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLC4

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLC4A

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLCA

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLCA-55-G5

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-F-SLCA-G5

622 Mbps Single Mode SFF LC Transceiver
SOURCE

C-13-622-FDFB-SLC

622 Mbps Single Mode SFF LC Transceiver
SOURCE