SPS-53-FE-BX-CDC [SOURCE]
SFP Bi-Directional Transceiver; SFP双向收发器型号: | SPS-53-FE-BX-CDC |
厂家: | SOURCE PHOTONICS, INC. |
描述: | SFP Bi-Directional Transceiver |
文件: | 总7页 (文件大小:525K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Features
• Compliant with OC3/STM-1, IEEE 802.3ah, 100BASE-BX10
• Simplex SC Connector
• Digital Diagnostic SFF-8472 Compliant
• SFP MSA SFF-8074i Compliant
• 14 dB Minimum Power Budget
• 10 km Typical reach
• Commercial and Industrial Temperature Available
• Single 3.3V Supply
• 1530 nm FP Laser
• Telcordia GR-468 Compliant
• Color Coded Yellow Bail Latch
• RoHS-6/6 compliant (lead free soldering) (-xxC)
General Operation
Parameter
Symbol
Vcc
Min.
3.135
-
Typ.
Max.
3.465
300
-
Unit
V
Supply Voltage
3.3
Total Current
ICC
-
-
-
-
-
-
mA
mVp-p
ºC
Power Supply Noise Rejection
Operating Temerature (-Cxx)
Operating Temerature (-Txx)
Storage Temperature
Data Rate
100
-5
Topr
Topr
Tstg
DR
70
-40
-40
10
85
ºC
85
ºC
155
Mbps
Transmitter Specifications (Optical)
Parameter
Symbol
Pop
Min
-14
-
Typical
Max
-8
Unit
dBm
dB
-11
-45
-
Optical power
XT
-40
-45
-
Optical crosstalk
Poff
-
dBm
dB
Average Launch power of off Tx
Extinction Ratio
ER
6.6
-
Eye Mask
IEEE 802.3 and SONET/SDH Compliant
Optical Rise time (20% to 80% values)
Optical Fall time (20% to 80% values)
Mean Wavelength
tr
tf
-
-
2
2
ns
ns
-
-
λ
1480
1530
1580
4
nm
nm
dB/Hz
dB
Spectral Width (RMS)
σ
2
-
-
-
-
Relative Intensity Noise
RIN
ORLT
-120
12
Optical Return Loss Tolerance
-
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
1
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Transmitter Specifications (Electrical)
Parameter
Symbol
Rin
Min
Typical
Max
120
Unit
Ω
80
250
2
100
Input Differential Impedence
PECL Single Ended data input swing
TxFault_Fault
Vin, p-p
Vfault
Vnormal
Vd
-
-
-
-
-
1200
mV
V
Vcc
TxFault_Normal
Vee
2
Vee + 0.5
Vcc
V
TxDisable_Disable
V
TxDisable_Enable
Ven
Vee
Vee + 0.8
V
Receiver Specifications (Optical)
Parameter
Symbol
Min
Typical
Max
Unit
dBm
dBm
dBm
nm
a
Receiver Power Low
Rsens,low
-
-8
-30
-28.2
Receiver Power High
Damage Threshold for Receiver
Wavelength
Rsens,high
-
-
-
-
-
-
-
Pin, damage
4
-
λ
-
1260
-45
-
1360
LOS Assert
-
-28.2
-
dBm
dBm
dB
LOS De-assert
-
LOS hysteresis
-
1
a) at 10-12 BER, PRBS 27-1
Receiver Specifications (Electrical)
Parameter
Symbol
Min
Typical
Max
800
2
Unit
mV
ns
Vout,p-p
185
-
-
-
CML Single ended data output swing
Data output rise time
tr
tf
-
-
Data output fall time
2
ns
Timing and Electrical
Parameter
Symbol
Min
Typical
Max
Unit
t_on
t_off
-
-
-
-
-
-
-
-
25
10
ms
µs
Tx Disable Negate time
Tx Disable assert time
Time to initialize, including reset of Tx fault
Tx fault Assert time
t_init
t_fault
300
100
ms
µs
Tx Disable to reset
t_reset
t_loss_on
t_loss_off
f_serial_clock
Rx_LOSH
10
-
-
-
-
-
-
-
-
-
-
1000
100
100
-
µs
µs
µs
KHz
V
LOS Assert time
LOS De-assert time
-
-
2
Serial ID Clock Rate
RX_LOS Voltage (high)
RX_LOS Voltage (low)
LOS output voltage-Fault
LOS output voltage-Normal
RX_LOSL
-
0.8
V
VLOS fault
VLOS normal
2
Vcc
V
Vee
Vee + 0.5
V
MOD_DEF (0:2)-High
MOD_DEF (0:2)-Low
Vh
VI
2
-
-
V
V
Vcc
Vee
Vee + 0.5
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
2
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Diagnostics
Parameter
Range
-5 to 70
-40 to 85
0 to Vcc
0 to 120
Accuracy
Unit
ºC
Calibration Bit Value
Formula
Temperature (CDC)
Temperature (TDC)
Voltage
±3
±3
.1
Internal
Internal
Internal
External
1/256 C
1/256 C
100µV
-
Tc(C) = Tad(16 bit signed twos complement)/256
Tc(C) = Tad(16 bit signed twos complement)/256
V(Volts) = Vad(16 bit unsigned integer)*0.1
I(mA) = Islope * Iad(16 bit unsigned integer)+Ioffset
ºC
V
Bias Current
5
mA
Tx_PWR(µW) = Tx_PWRslope*Tx_PWRad(16 bit unsigned
integer)+Tx_PWRoffset
Tx Power
Rx Power
-14 to -8
±3
±3
dBm
dBm
External
External
-
-
-28.2 to -8
Rx_PWR(µW) = A0+A1*x+A2*x^2+A3*x^3+A4*x^4
Pinout Definitions
Pin
Function
Notes
TX GND
V
T
1
2
ee
TX_FAULT
Open Collector
3
4
TX_DISABLE
MOD_DEF2
MOD_DEF1
MOD_DEF0
NC
Internally Pulled High
Serial Data Input
Serial Clock Input
Internally Grounded
Not Connected
Open Collector
RX Ground
5
6
7
8
LOS
9
V
V
V
R
R
R
ee
ee
ee
10
11
12
13
14
15
16
17
18
19
20
RX Ground
RX Ground
RXD-
RX Data Negative
RX Data Positive
RX GND
RXD+
V
R
ee
V
V
R
RX Power
CC
CC
T
TX Power
V
T
TX GND
ee
TXD+
TXD-
TX Data Positive
TX Data Negative
TX GND
V
T
ee
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
3
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
EEPROM Serial ID
Name of Field
Discription of Field
Address
20
Hex
4C
55
40
49
4E
ASCII
L
U
M
I
21
22
23
24
N
E
SFP Vendor name (ASCII)
25
45
4E
Vendor Name
26
N
T
27
54
4F
28
O
I
29
49
43
30
C
37
38
39
00
06
B5
Vendor OUI
IEEE vendor OUI code for LuminentOIC
40
41
42
43
44
45
46
49
50
51
52
53
53
50
53
35
33
46
45
42
58
43
44
43
S
P
S
5
3
F
Part number in ASCII, e.g.
SPS-53-FE-BX-CDC
Vendor PN
E
B
X
C
D
C
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
4
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
SC Connector Mechanical
Units in mm(inches)
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
5
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Suggested Transceiver Interface
1�H
1�H
Vcc
10�F
0.1�F
VCCT
.01�F
Protocol IC
LuminentOIC
SFP
R1
10Kꢀ
TX_DISABLE
TX_DISABLE
TX_FAULT
TD +
Laser Driver
TX_FAULT
.01�F
SerDes
100ꢀ
TD -
.01�F
VEET
VCCR
0.1�F
RD +
10�F
Receiver Amplifier
.01�F
.01�F
100ꢀ
RD -
RX_LOS
VEER
RX_LOS
Vcc
R
EEPROM
1
R1
R1
R1
MOD_DEF 2
MOD_DEF 1
MOD_DEF 0
R1=4.7K to 10Kꢀ
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
6
SFP Bi-Directional Transceiver
SPS-53-FE-BX-xxC
Ordering Information
Available Options:ꢀ
SPS-53-FE-BX-CDC
SPS-53-FE-BX-TDC
SPS-53-FE-BX-CNC
SPS-53-FE-BX-TNC
Part numbering Definition:
SPS - 53 - FE - BX -
Temperature Diagnostic Revision
• SPS = SC connector
• Wavelength
53 = Tx 1530nm/Rx 1310nm
• Data Rate
FE = Fast Ethernet (100Mbps)
• Standard
BX = 100BASE-BX
• Operatating Temperature
C = Commercial temperature (-5 to 70ºC)
T = Industrial temperature (-40 to 85ºC)
• D = Digital Diagnostic (SFF-8472)
N = No Diagnostic
• Design Revision
C = RoHS-6/6 compliant (lead free soldering)
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow
guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notes:
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance
of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are
given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warran-
ties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of
Sale for further warranty information.
LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual
property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes
no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this docu-
ment are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers
using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from
such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any
actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.
© LuminentOIC, Inc. 2003
All rights reserved
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMINENTOIC.COM
LUMNDS1578-Jan1107
Rev A.3
7
相关型号:
©2020 ICPDF网 联系我们和版权申明