PPTC/K60 Series  
Features  
Radial leaded Devices  
Applications  
Almost anywhere there is a low voltage  
power supply, up to DC30V and a load  
to be protested, including:  
Automotive electronics  
Medical products  
Cured,flame retardant epoxy polymer  
insulating material meets UL94V-0  
requirements  
Bulk packaging,or tape and reel  
available on most models  
Industrial controls  
Product dimensions (mm)  
Model  
K60-005  
K60-010  
K60-017  
K60-020  
K60-025  
Fig  
1(2)  
1(2)  
1(2)  
1(2)  
11(2)  
1(2)  
2
A(max)  
5.0  
B(max)  
8.5  
C(max)  
D(typ)  
5.1  
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
5.5  
9.5  
5.1  
7.4  
12.7  
12.7  
12.7  
13.0  
16.2  
16.2  
17.8  
18.4  
18.4  
18.0  
18.0  
19.6  
21.3  
22.9  
22.9  
26.4  
26.4  
33.5  
33.5  
5.1  
7.4  
5.1  
7.4  
5.1  
-
7.4  
5.1  
K60-030  
K60-040  
K60-050  
K60-065  
K60-075  
K60-090  
K60-110Y  
K60-110F  
K60-135  
K60-160  
K60-185  
K60-200  
K60-250  
K60-300  
K60-375  
K60-500  
7.8  
5.1  
2
7.8  
5.1  
2
9.7  
5.1  
2
10.4  
11.7  
13.0  
13.0  
14.5  
16.3  
17.8  
17.8  
21.3  
21.3  
28.5  
28.5  
5.1  
2
5.1  
1
5.1  
3
5.1  
1
5.1  
1
5.1  
1
5.1  
1
5.1  
1
10.2  
10.2  
10.2  
10.2  
1
1
1
Physical Characteristcs  
Material:Leads  
K60-005030  
K60-040090  
K60-300500  
Tin plated copper,22AWG0.60mm or Tin-plated nickel-copper alloy,24AWG0.50mm  
Tin plated copper,22AWG,0.60mm  
Tin plated copper,20AWG,0.80mm  
Environmental Specifications  
Test  
conditions  
Resistance change  
±8% typical  
Passive aging  
85,100hts  
85,85%R.H.,100hrs  
125,to-55,10times  
MIL-STD-202,Method 215  
MIL-STD-202,Method 201  
Humidity aging  
Thermal shock  
Resistance to solvent  
±8% typical  
±12% typical  
No change  
No change  
Vibration  
Storage conditions:-40to 85℃  
01 | www.spsemi.cn  
REV.2014.05.01  
PPTC/K60 Series  
Electrical characteristics(25  
)
Part  
Ihold  
Itrip  
Vmax  
Imax  
Pd max  
Maximum Time To Trip  
Resistance  
number  
Current  
(A)  
Time  
(S)  
5
5
5
5
5
5
5
5
5
5
5
8
8
8
8
Rmin  
(Ω)  
Rmax  
(Ω )  
20.00  
7.50  
5.21  
2.84  
1.95  
1.38  
0.88  
0.79  
0.50  
0.42  
0.33  
0.27  
0.27  
0.21  
0.16  
0.14  
0.14  
0.10  
0.08  
0.06  
0.06  
R1max  
(Ω)  
(A)  
0.05  
0.10  
0.17  
0.20  
0.25  
0.30  
0.40  
0.50  
0.65  
0.75  
0.90  
1.10  
1.10  
1.35  
1.60  
1.85  
2.00  
2.50  
3.00  
3.75  
5.00  
(A)  
0.10  
0.20  
0.34  
0.40  
0.50  
0.60  
0.80  
1.00  
1.30  
1.50  
1.80  
2.20  
2.20  
2.70  
3.20  
3.70  
4.00  
5.00  
6.00  
7.50  
10.00  
(Vdc)  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
60  
(A)  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
40  
(w)  
0.30  
0.38  
0.48  
0.41  
0.45  
0.49  
0.56  
0.77  
0.88  
0.92  
0.99  
0.15  
0.15  
0.12  
0.09  
0.08  
0.07  
0.05  
0.04  
0.03  
0.02  
K60-005  
K60-010  
K60-017  
K60-020  
K60-025  
K60-030  
K60-040  
K60-050  
K60-065  
K60-075  
K60-090  
K60-110Y  
K60-110F  
K60-135  
K60-160  
K60-185  
K60-200  
K60-250  
K60-300  
K60-375  
K60-500  
0.25  
0.50  
0.85  
1.00  
1.25  
1.50  
2.00  
2.50  
3.25  
3.75  
4.50  
5.50  
5.50  
6.75  
8.00  
9.25  
10.00  
12.50  
15.00  
18.75  
25.00  
7.30  
2.50  
2.00  
1.50  
1.00  
0.76  
0.55  
0.50  
0.31  
0.25  
0.20  
0.15  
0.15  
0.12  
0.09  
0.08  
0.07  
0.05  
0.04  
0.03  
0.02  
30.00  
12.00  
8.00  
4.49  
3.00  
2.20  
1.40  
1.20  
0.74  
0.62  
0.49  
0.40  
0.40  
0.32  
0.24  
0.21  
0.21  
0.15  
0.12  
0.10  
0.10  
8
8
8
8
24  
24  
Hold Current:Maximum current device will not trip in 25still air.  
Trip current:Minimum current at which the device will always trip in 25still air  
Ihold  
Itrip  
Vmax  
Imax  
Maximum operating volatge device can withstand without damage at ratde current(imax).  
Maximum fault current device can withstand without damage at rated voltage(Vmax).  
Typical power dissipatde from device when in the tripped state in 25still air.  
Minimum/Maximum device resistance prior to tripping at 25.  
Pd  
Rmin/max  
R1max  
Maximum resistance of device at 25measured one hour after trippde tripping.  
*CAUTION Operation beyond the specified rating may result in damage and possible arcing.  
Thermal Derating Chart-IH(A)  
)
Maximum ambidnt operating temperatures(℃  
Part number  
-40  
0.077  
0.18  
0.28  
0.34  
0.42  
0.52  
0.66  
0.83  
1.10  
1.26  
1.52  
1.82  
1.82  
2.20  
2.60  
3.00  
3.21  
4.05  
4.82  
6.02  
8.00  
-20  
0.069  
0.15  
0.24  
0.29  
0.36  
0.44  
0.57  
0.74  
0.95  
1.11  
1.30  
1.60  
1.60  
1.91  
2.30  
2.63  
2.72  
3.58  
4.16  
5.19  
6.80  
0
25  
0.050  
0.10  
0.17  
0.20  
0.25  
0.30  
0.40  
0.50  
0.65  
0.75  
0.90  
1.10  
1.10  
1.35  
1.60  
1.85  
2.00  
2.50  
3.00  
3.75  
5.00  
40  
0.044  
0.08  
0.14  
0.16  
0.20  
0.24  
0.32  
0.41  
0.53  
0.61  
0.73  
0.90  
0.90  
1.09  
1.30  
1.50  
1.62  
2.02  
2.43  
3.02  
4.05  
50  
0.040  
0.07  
0.12  
0.14  
0.18  
0.22  
0.29  
0.36  
0.47  
0.54  
0.65  
0.79  
0.79  
0.96  
1.13  
1.33  
1.44  
1.80  
2.16  
2.68  
3.60  
60  
0.036  
0.06  
0.10  
0.13  
0.16  
0.18  
0.24  
0.30  
0.40  
0.45  
0.55  
0.65  
0.65  
0.80  
1.00  
1.12  
1.26  
1.55  
1.85  
2.30  
3.15  
70  
0.032  
0.05  
0.09  
0.10  
0.12  
0.14  
0.20  
0.25  
0.33  
0.39  
0.47  
0.55  
0.55  
0.68  
0.80  
0.92  
1.08  
1.30  
1.50  
1.95  
2.70  
80  
0.025  
0.03  
0.06  
0.07  
0.09  
0.10  
0.14  
0.18  
0.24  
0.28  
0.33  
0.40  
0.40  
0.50  
0.60  
0.67  
0.80  
0.90  
1.09  
1.39  
2.00  
K60-005  
K60-010  
K60-017  
K60-020  
K60-025  
K60-030  
K60-040  
K60-050  
K60-065  
K60-075  
K60-090  
K60-110Y  
K60-110F  
K60-135  
K60-160  
K60-185  
K60-200  
K60-250  
K60-300  
K60-375  
K60-500  
0.061  
0.13  
0.20  
0.25  
0.31  
0.38  
0.50  
0.63  
0.82  
0.95  
1.15  
1.35  
1.35  
1.65  
1.95  
2.30  
2.38  
3.02  
3.62  
4.50  
5.95  
REV.2014.05.01  
02 | www.spsemi.cn  
PPTC/K60 Series  
Typical Time-To-Trip Curve At 25°C  
Thermal Derating Curve  
0.100A  
0.170A  
0.200A  
0.250A  
0.300A  
0.400A  
0.500A  
0.650A  
0.750A  
0.900A  
1.10A  
Average Time Current Curves  
1000  
Derating Curves for K60 Series  
180  
160  
140  
120  
100  
80  
100  
10  
1
1.35A  
60  
1.60A  
1.85A  
40  
0.1  
0.01  
2.50A  
3.00A  
20  
3.75A  
0
-40  
-20  
0
20  
40  
60  
80  
0.1  
1
10  
100  
CURRENT IN AMPERES  
Temperature (°C)  
Package Information  
Bulk:  
K60-005110Y  
K60-110F300  
1000pcs per bag  
500pcs per bag  
k60-375500  
200pcs per bag  
REV.2014.05.01  
03 | www.spsemi.cn  

相关型号:

K60-300

Radial leaded Devices
SPSEMI

K60-375

Radial leaded Devices
SPSEMI

K600-110U

Radial leaded Devices
SPSEMI

K600-150U

Radial leaded Devices
SPSEMI

K600-160U

Radial leaded Devices
SPSEMI

K6002D

COLOR CHIPS MMVP RED
ETC

K6003B

COLOR CHIPS MMVP ORANGE
ETC

K6004B

MMVP Series Micro Video Patchbays
SWITCH

K6005N

COLOR CHIPS MMVP GREEN
ETC

K6006L

COLOR CHIPS MMVP BLUE
ETC

K603010000J0G

Barrier Strip Terminal Block
AMPHENOL

K604019000J0G

Barrier Strip Terminal Block
AMPHENOL