FN3840-50-53-C35-R65 [Schaffner]
Book-style EMC/RFI Filter for regenerative drive application;型号: | FN3840-50-53-C35-R65 |
厂家: | Schaffner International Ltd |
描述: | Book-style EMC/RFI Filter for regenerative drive application |
文件: | 总6页 (文件大小:1090K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
3-Phase Filters FN3840
DATASHEET
Book-style EMC/RFI Filter for regenerative drive application
Designed for usage together with LCL filter
Approvals & Compliances
Easy design in with system approach
documentation
Footprint space-saving book-style housing
Thermal shutdown capability
Solid safety connector blocks
Versions with low leakage current
Features and benefits
FN 3840 series of filters provides state-of-the-art EMI
attenuation based on an innovative filter topology.
They help to ensure compliance with Class C2 or
even C1 limits.
Performance indicators
The filters are built to fit perfectly to regenerative
drive applications with LCL filters
Internal thermocouples ensure reliability and
thermal shutdown capabilities
The slim book-style shape allows a convenient and
space-saving installation next to inverters,
converters or motor drives.
The filters offer very high saturation performance,
bundled with best EMI performance
Fulfills the requirements in IEC/EN 61800-5-1 for
electric strength, clearance and creepage
Technical specifications
Fulfills the requirements in IEC/EN 60204-1 for
insulation resistance, electric strength, clearance
and creepage
3x 530/305 VAC
DC to 60 Hz
Maximum continuous operating voltage
Operating frequency
Fulfills the requirements in IEC/EN 62477-1 for
electric strength, clearance and creepage
25 to 380 A @50°C
Rated currents
6x rated current for 1 sec, once per hour
Overload capability
1.6x rated current for 1 minute, once per hour
Typical applications
40/100/21 acc. to IEC 60068-1
Climatic class
-40°C to +100°C (with current derating >50°C)
Temperature range (operation and storage)
High potential test voltage
Regenerative drives in combination with LCL filters
Active infeed converter (AIC)
P -> E 2550 VDC for 2 s
P -> P 2550 VDC for 2 s
Active front end (AFE) variable frequency drives
(VFD)
TS/TS' -> E 2550 VDC for 2 s
TS/TS' -> P 2550 VDC for 2 s
2 acc. IEC 60664-1
Pollution degree
Overvoltage category
Surge withstand
Altitude
Three-phase variable speed drives (VSD) and power
drive systems (PDS)
III acc. IEC 60664-1
2kV (P-P) / 4kV (P - E) acc. to IEC 6100-4-5
Renewable Energy
up to 2000m no derating applies. Above 2000m
derating acc. to IEC 60664-1 applies
Machine tool and machinery equipment
Process automation equipment
UL 60939-3, IEC 60939-3
Design corresponding to
> 1MOhm acc. to IEC 60204-1
Compliance with insulation requirement
Protection category
IP 20 (terminal block versions) and IP00 (busbar
versions) acc. to IEC 60529-1
Typical electrical schematic (please refer to page
2 for further details)
3M4 (operation) acc. to IEC 60721-3-3
Terminals: UL 94 V-0
Vibration and shock
Flammability corresponding to
MTBF
L1
L2
L3
L1'
L2'
L3'
> 300,000 hours
PE
PE
2
EMC/EMI Products
Schaffner Group Datasheets 26 Nov 2020
Filter selection table
Rated
Leakage
DC
Typical Power
Dissipation
Terminal
Type Weight
Thermal
Filter
current Typical drive
current**
Resistance
Switch***
power
@ 50°C
[A]
rating* @ 530 VAC/50 Hz
@ 25°C
[mOhm]
9.5
Switching Temp.
[kW]
15
[mA]
4.3
[W]
22
43
40
40
26
33
[kg]
2.5
3.5
5.7
7.9
4.3
4.5
[°C]
180
180
180
180
150
150
FN3840-25-33-C35-R65
FN3840-50-53-C35-R65
FN3840-80-34-C45-R65
FN3840-160-40-C45-R65
FN3840-250-99-C2835-R67
FN3840-380-99-C2835-R67
25
-33
-53
-34
-40
-99
-99
50
30
4.3
5
80
45
7.7
1.5
160
250
380
90
7.7
0.4
150
200
10.7
10.7
0.1
0.07
*
Typical power rating at 400 VAC with cos phi=0.85. The exact value depends upon the efficiency of the drive, the motor and the entire application.
** Standardized calculated leakage current acc. IEC 60939 under normal operating conditions.
*** Normally closed thermal protector switch, 250VAC / 24VDC, 6.3A (with cos phi 0.6); reverse switching temperature = switching temp - 50K.
Typical electrical schematic (≤160A)
Typical electrical schematic (≥250A)
L1
L2
L3
L1'
L2'
L3'
L1
L2
L3
L1'
L2'
L3'
PE
PE
PE
PE
Tolerances apply: L +50%/-30% , C ±20%, R ±10%
Typical filter attenuation
Per CISPR 17: symmetrical 50 Ω/50 Ω -> Differential Mode (DM); asymmetrical 50 Ω/50 Ω -> Common Mode (CM)
FN3840-25-33-C35-R65
FN3840-50-53-C35-R65
FN3840-80-34-C45-R65
FN3840-160-40-C45-R65
FN3840-250-99-C2835-R67
FN3840-380-99-C2835-R67
3
EMC/EMI Products
Schaffner Group Datasheets 26 Nov 2020
Typical application
System diagram of an Active Front End (AFE) application
ULINE
LCL
L1
L2
LGRID
U
s
AFE
VFD
L1
L2
L3
L1
L2
L3
L1
L2
L3
U
V
W
U
V
W
L1'
L2'
L3'
L1'
L2'
L3'
EMI
Filter
Cf
M
I
g
PE
PE
PE
PE
PE
PE
PE
Frequency response
Frequency response at different values of the grid inductance. The grid inductance is calculated with details mentioned at each graph. Each figure represents the
normalized admittance transfer function between the grid current, ig, and the converter voltage us. At low frequencies, the equivalent admittance is inversely
proportional to the total DC resistance of the grid, and EMI and LCL filters (RGRID+REMI+RLCL), which is dominated mainly by the LCL filter RLCL.
FN3840-25-33-C35-R65
FN3840-50-53-C35-R65
400 VAC/50 Hz, 250 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
400 VAC/50 Hz, 250 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
FN3840-80-34-C45-R65
FN3840-160-40-C45-R65
400 VAC/50 Hz, 250 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
400 VAC/50 Hz, 315 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
FN3840-250-99-C2835-R67
FN3840-380-99-C2835-R67
400 VAC/50 Hz, 500 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
400 VAC/50 Hz, 630 kVA trafo with uk of (1) 1%, (2) 2%, (3) 3%, (4) 4%, (5) 5%
and 50m cable.
4
EMC/EMI Products
Schaffner Group Datasheets 26 Nov 2020
Damping resistor losses vs switching frequency
Typical losses at different values of the AFE-LCL L1 inductor with rated voltage (530 VAC/60 Hz) and differing grid inductance. (25A->95µH; 50A->95µH; 80A-> 95µH;
160A->79µH; 250A->57µH; 380A->50µH).
The highlighted gray area represents a non-operating area. Operating the filter in this area may cause overheating and damage to the filter, and may activate the
temperature switch.
FN3840-25-33-C35-R65
FN3840-50-53-C35-R65
FN3840-80-34-C45-R65
FN3840-160-40-C45-R65
FN3840-250-99-C2835-R67
FN3840-380-99-C2835-R67
Mechanical data for filters with terminal blocks
FN3840-25-33-CXX-RYY
FN3840-50-53-CXX-RYY
5
EMC/EMI Products
Schaffner Group Datasheets 26 Nov 2020
FN3840-80-34-CXX-RYY
FN3840-160-40-CXX-RYY
Filter input/output connector cross sections
-40
-33
-53
-34
2
2
2
2
2
2
Solid wire
0.5-16 mm
0.5-16 mm
6-35 mm
25-95 mm
2
2
Flex wire
0.5-10 mm
0.5-16 mm
6-25 mm
AWG 6-2
25-95 mm
Flex wire AWG
AWG 22-6
1.5-1.8 Nm
AWG 20-4
2.0-2.3 Nm
AWG 0-4/0
17-20 Nm
Recommended torque
4.0-4.5 Nm
Please visit www.schaffner.com to find more details on filter connectors.
Mechanical data for filters with busbar connection
FN3840-250-99-CXXXX-RYY
FN3840-380-99-CXXXX-RYY
6
EMC/EMI Products
Schaffner Group Datasheets 26 Nov 2020
Headquarters, global
innovation and development
Sales and application centers
Switzerland
China
Spain
Schaffner Group
Industrie Nord
Schaffner EMC Ltd. Shanghai
T20-3 C, No 565 Chuangye Road,
Pudong district
Schaffner EMC España
Calle Caléndula 93, Miniparc III, Edificio E
El Soto de Moraleja, Alcobendas
28109 Madrid
Nordstrasse 11e
4542 Luterbach
T +41 32 681 66 26
info@schaffner.com
201201 Shanghai
T +86 21 3813 9500
cschina@schaffner.com
www.schaffner.com.cn
T +34 917 912 900
F +34 917 912 901
spainsales@schaffner.com
Finland
Sweden
Schaffner Oy
Schaffner EMC AB
Östermalmstorg 1
114 42 Stockholm
T +46 8 5050 2425
swedensales@schaffner.com
www.schaffner.com
Sauvonrinne 19 H
08500 Lohja
T +358 10 567 2855
finlandsales@schaffner.com
France
Schaffner EMC S.A.S.
16-20 Rue Louis Rameau
95875 Bezons
Switzerland
Schaffner EMV AG
Industrie Nord
T +33 1 34 34 30 60
F +33 1 39 47 02 28
francesales@schaffner.com
Nordstrasse 11e
4542 Luterbach
T +41 32 681 66 88
T +41 32 681 66 26
switzerlandsales@schaffner.com
Germany
Schaffner Deutschland GmbH
Schoemperlenstrasse 12B
76185 Karlsruhe
Taiwan R.O.C.
Schaffner EMV Ltd.
T +49 721 56910
20 Floor-2, No 97, Section 1, XinTai 5th Road
22175 XiZhi District New Taipei City 22175
T +886 2 2697 5500
F +49 721 569110
germanysales@schaffner.com
F +886 2 2697 5533
India
taiwansales@schaffner.com
www.schaffner.com.tw
Schaffner India Pvt. Ltd
REGUS WORLD TRADE CENTRE
WTC, 22nd Floor Unit No 2238, Brigade
Gateway Campus, 26/1, Dr. Rajkumar Road
Malleshwaram (W)
Thailand
Schaffner EMC Co. Ltd.
Northern Region Industrial Estate
67 Moo 4 Tambon Ban Klang
Amphur Muangg P.O. Box 14
51000 Lamphun
560055 Bangalore
T +91 80 67935355
indiasales@schaffner.com
T +66 53 58 11 04
Italy
F +66 53 58 10 19
Schaffner EMC S.r.l.
Via Ticino, 30
thailandsales@schaffner.com
20900 Monza (MB)
T +39 039 21 41 070
italysales@schaffner.com
United Kingdom
Schaffner Ltd.
To find your local partner within Schaffner‘s
global network: www.schaffner.com
1, Oakmede Place
Binfield
© 2020 Schaffner Group
Japan
RG42 4JF Berkshire
T +44 118 9770070
F +44 118 9792969
uksales@schaffner.com
Schaffner EMC K.K.
Taiju-Seimei Sangenjaya Bldg.
1-32-12, Kamiuma, Setagaya-ku
154-0011 Tokyo
The content of this document has been
carefully checked and understood. However,
neither Schaffner nor its subsidiaries assume
any liability whatsoever for any errors or
inaccuracies of this document and the
consequences thereof. Published specifica-
tions are subject to change without notice.
Product suitability for any area of application
must ultimately be determined by the
customer. In all cases, products must never
be operated outside their published
specifications. Schaffner does not guarantee
the availability of all published products. This
disclaimer shall be governed by substantive
Swiss law and resulting disputes shall be
settled by the courts at the place of business
of Schaffner Holding AG. Latest publications
and a complete disclaimer can be downloa-
ded from the Schaffner website. All
trademarks recognized.
T +81 3 5712 3650
USA
F +81 3 5712 3651
Schaffner EMC Inc.
52 Mayfield Avenue
Edison, New Jersey
T +1 732 225 9533
F +1 732 225 4789
usasales@schaffner.com
www.schaffnerusa.com
japansales@schaffner.com
www.schaffner.jp
Singapore
Schaffner EMC Pte Ltd.
#05-09, Kg Ubi Ind. Estate
408705 Singapore
T +65 6377 3283
F +65 6377 3281
singaporesales@schaffner.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明