ECX-003 [TDK]
AC-DC Regulated Power Supply Module, 2 Output, 43.5W,;型号: | ECX-003 |
厂家: | TDK ELECTRONICS |
描述: | AC-DC Regulated Power Supply Module, 2 Output, 43.5W, |
文件: | 总21页 (文件大小:295K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A131_ECX
(1/21)
TDK Switching Power Supply
Mechatronics power supply with 5V and 24V insulated
E SERIES ECX
[FEATURES]
• AC.100V/200V input and switching type.
• Floating between outputs 5V and 24V.
• Large 24V peak current (ECX-001/-003/-005/-007).
• Optimum for pulse load and mechanism drive.
• Compact and lightweight.
[SUMMARY]
The E series ECX products are 2-output power supplies of 5V
type for a logic circuit and 24V type for driving a mechanism. This
series has no limitation on the minimum output current and has
superior characteristics of dynamic load variation from a light load
to a rated load so as to obtain a large peak current (24V output),
thus enabling a wide variety of uses for mechatronics.
PART NUMBERS AND RATINGS
Maximum output power(W)
Output current(A)
5V
Part No.
(Peak)
29(41)
39
24V
24V Peak
ECX-001
ECX-002
ECX-003
ECX-004
ECX-005
ECX-006
ECX-007
0 to 1
0 to 1
0 to 1
0 to 1.5
0 to 2
0 to 3
0 to 3
0 to 6
1.5(10s min.)
3(10s min.)
5(10s min.)
10(10s min.)
0 to 3
43.5(79.5)
63
0 to 1.5
0 to 3
82(130)
87
0 to 2
0 to 3
159(255)
0 to 3
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
Open frame type
ECX-00 A( : only for 1, and 2)
L-shape frame type
ECX-00
ECX-00
D
E
Connector(Vertical)
∗ There are 1 to 7 types available for the square
.
All specifications are subject to change without notice.
A131_ECX
(2/21)
TDK Switching Power Supply
E SERIES ECX-001
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-001
Rated output voltage
and current∗1
V1
V2
W
5V • 1A
24V • 1A(Peak current 1.5A)
29[Peak current output: 41]
Maximum output power
INPUT CONDITIONS
Input voltage Eac∗6
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
1max.[25°C, input and output ratings]
3[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
75typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
24(V2)
V
Fixed
Fixed
A
1
1(Peak current 1.5A 10s max.)
A
0
0
%
1max.
3.5max. [Within the input voltage range]
Load variation∗3
%
2max.
5max.
2max.
[V2: 10 to 100%]
∗4 Total variation 5max.(24V: 10max.)
Voltage
stability
Temperature variation
%
1max.
[Ambient temperature: 0 to +40°C]
Drift
%
0.5max.
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple Ep-p∗5
Ripple noise Ep-p∗5
V/ms
mV
mV
s
—
2.4(Voltage variation)/5(Reset time)[0.1 to 1.5A sudden load change]
100max.
600max.
800max.
150max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or winker
operation(restart requires roughly 5min wait).
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
A type: 24×93×119[H×W×L] D, E type: 25×95×120[H×W×L]
300max.
Mounting method
Case material
Can be attached to 2 sides(Without frame type can be attached to 1 side).
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
Open frame type L-shape frame type
ECX-001A
ECX-001D
ECX-001E
Connector(Vertical)
All specifications are subject to change without notice.
A131_ECX
(3/21)
TDK Switching Power Supply
E SERIES ECX-001
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-001
M4×8
110 0.7
4-M3 Screw tap
∗4-ø3.5
5 0.3
(5)
(5.6) 20.4max.
(for mounting, rear view) (for mounting)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
∗4.5 0.4
∗119 1
120 1
5 0.3
55 0.4
UP
55 0.4
(5)
ECX-001D(With frame)
3-M3
Screw tap
(for mounting)
ECX-001A(Without frame)
UP
(
): for reference dimensions ∗ mark is in case of without housing type.
All specifications are subject to change without notice.
A131_ECX
(4/21)
TDK Switching Power Supply
E SERIES ECX-002
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-002
5V • 3A
24V • 1A
39
Rated output voltage
and current∗1
V1
V2
W
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60]](Single phase)
1.2max.[25°C, input and output ratings]
3[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
75typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
Fixed
3
24(V2)
Fixed
1
V
A
A
0
0
%
1max.
2max.
1max.
1max.
—
3.5max.
[Within the input voltage range]
Load variation∗3
%
+10, –8max. [V2 : 10 to 100%]
5max. [0 to +40°C]
∗4 Total variation 5max.(24V: +15, –10max.)
Voltage
stability
Temperature variation
%
Drift
%
5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗5 Ep-p
Ripple noise∗5 Ep-p
V/ms
mV
mV
s
—
100max.
150max.
600max.
800max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
Upon overcurrent detection, outputs are lowered and winker operates. Recovery when input reset
(restart requires roughly 5min wait).
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
A type: 24×93×119[H×W×L]] D, E type: 25×95×120[H×W×L]
300max.
Mounting method
Case material
Can be attached to 2 sides(Without frame type can be attached to 1 side).
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
Open frame type L-shape frame type
ECX-002A
ECX-002D
ECX-002E
Connector(Vertical)
All specifications are subject to change without notice.
A131_ECX
(5/21)
TDK Switching Power Supply
E SERIES ECX-002
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-002
M4×8
110 0.7
4-M3 Screw tap
∗4-ø3.5
5 0.3
(5)
(5.6) 20.4max.
(for mounting, rear view) (for mounting)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
∗4.5 0.4
∗119 1
120 1
5 0.3
55 0.4
UP
55 0.4
(5)
ECX-002D(With frame)
3-M3
Screw tap
(for mounting)
ECX-002A(Without frame)
UP
(
): for reference dimensions ∗ mark is in case of without housing type.
All specifications are subject to change without notice.
A131_ECX
(6/21)
TDK Switching Power Supply
E SERIES ECX-003
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-003
Rated output voltage
and current∗1
V1
V2
W
5V • 1.5A
24V • 1.5A(Peak current 3A)
43.5[Peak current output: 79.5]
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
1.5max.[25°C, input and output ratings]
3[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
77typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
24(V2)
V
Fixed
Fixed
A
1.5
1.5(Peak current 3A 10s max.)
A
0
0
%
1max.
3.5max. [Within the input voltage range]
Load variation∗3
%
2max.
5max.
2max.
[V2: 10 to 100%]
∗4 Total variation 5max.(24V: 10max.)
Voltage
stability
Temperature variation
%
1max.
[0 to +40°C]
Drift
%
0.5max.
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗5 Ep-p
Ripple noise∗5 Ep-p
V/ms
mV
mV
s
—
2.4(Voltage variation)/5(Reset time)[0.3 to 3A sudden load change]
100max.
600max.
800max.
150max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
V1, V2 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
V1 alone uses voltage lowering. V2 entirely shuts off output upon overcurrent detection or winker operation
(restart requires roughly 5min wait).
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
30×95×130[H×W×L]
400max.
Mounting method
Case material
Can be attached to 2 sides.
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
L-shape frame type
ECX-003D
Connector(Vertical)
ECX-003E
All specifications are subject to change without notice.
A131_ECX
(7/21)
TDK Switching Power Supply
E SERIES ECX-003
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-003
M4×8
120 0.7
4-M3 Screw tap
5 0.3
(5)
(5.6) 25.4max.
(for mounting, rear view)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
∗4.5 0.4
∗129 1
130 1
5 0.3
120 0.7
(5)
2-M3 Screw tap
(for mounting)
ECX-003D(With frame)
UP
(
): for reference dimensions
All specifications are subject to change without notice.
A131_ECX
(8/21)
TDK Switching Power Supply
E SERIES ECX-004
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-004
5V • 3A
24V • 2A
63
Rated output voltage
and current∗1
V1
V2
W
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
1.8max.[25°C, input and output ratings]
3[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
75typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
Fixed
3
24(V2)
Fixed
2
V
A
A
0
0
%
1max.
2max.
1max.
1max.
—
3.5max.
[Within the input voltage range]
Load variation∗3
%
10, –8max. [V2: 10 to 100%]
5max. [0 to +40°C]
∗4 Total variation 5max.(24V: +15, –10max.)
Voltage
stability
Temperature variation
%
Drift
%
5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗5 Ep-p
Ripple noise∗5 Ep-p
V/ms
mV
mV
s
—
100max.
150max.
600max.
800max.
Start up time
1.5max.(Rise time: 20ms max.)
10min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
Upon overcurrent detection, outputs are lowered and winker operates.
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
30×95×130[H×W×L]
400max.
Mounting method
Case material
Can be attached to 2 sides.
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
L-shape frame type
ECX-004D
Connector(Vertical)
ECX-004E
All specifications are subject to change without notice.
A131_ECX
(9/21)
TDK Switching Power Supply
E SERIES ECX-004
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-004
M4×8
120 0.7
4-M3 Screw tap
(5)
5 0.3
(5.6) 25.4max.
(for mounting, rear view)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
130 1
120 0.7
5 0.3
(5)
UP
2-M3 Screw tap
(for mounting)
(
): for reference dimensions
All specifications are subject to change without notice.
A131_ECX
(10/21)
TDK Switching Power Supply
E SERIES ECX-005
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-005
Rated output voltage
and current∗1
V1
V2
W
5V • 2A
24V • 3A(Peak current 5A)
82[Peak current output: 130]
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
2.5max.[25°C, input and output ratings]
5[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
82typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
24(V2)
V
Fixed
Fixed
A
2
3(Peak current 5A 10s max.)
A
0
0
%
1max.
3.5max. [Within the input voltage range]
Load variation∗3
%
2max.
8max.
2max.
[V2: 10 to 100%]
∗4 Total variation 5max.(24V: 10max.)
Voltage
stability
Temperature variation
%
1max.
[0 to +40°C]
Drift
%
0.5max.
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗5 Ep-p
Ripple noise∗5 Ep-p
V/ms
mV
mV
s
—
2.4(Voltage variation)/5(Reset time)[0.5 to 5.0A sudden load change]
100max.
600max.
800max.
150max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
Upon overcurrent detection, outputs are lowered and winker operates.
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
30×95×160[H×W×L]
500max.
Mounting method
Case material
Can be attached to 2 sides.
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
L-shape frame type
ECX-005D
Connector(Vertical)
ECX-005E
All specifications are subject to change without notice.
A131_ECX
(11/21)
TDK Switching Power Supply
E SERIES ECX-005
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-005
M4×8
4-M3 Screw tap
5 0.3
150 0.7
(5)
(5.6)
25.4max.
(for mounting, rear view)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
160 1
5 0.3
150 0.7
(5)
2-M3 Screw tap
(for mounting)
UP
(
): for reference dimensions
All specifications are subject to change without notice.
A131_ECX
(12/21)
TDK Switching Power Supply
E SERIES ECX-006
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-006
5V • 3A
24V • 3A
87
Rated output voltage
and current∗1
V1
V2
W
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
2.5max.[25°C, input and output ratings]
5[Built-in]
Fuse rating
A
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, cold start]
1max.[25°C, input and output ratings]
82typ.
mA
%
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
Fixed
3
24(V2)
V
Fixed
A
3
A
0
0
%
1max.
2max.
1max.
0.5max.
—
3.5max. [Within the input voltage range]
Load variation∗3
%
8max.
2max.
[V2: 10 to 100%]
∗4 Total variation 5max.(24V: 10max.)
Voltage
stability
Temperature variation
%
[0 to +40°C]
Drift
%
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗5 Ep-p
Ripple noise∗5 Ep-p
V/ms
mV
mV
s
—
100max.
150max.
600max.
800max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗7
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
Upon overcurrent detection, outputs are lowered and winker operates.
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
30×95×160[H×W×L]
500max.
Mounting method
Case material
Can be attached to 2 sides.
Without cover(With frame also available)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
L-shape frame type
ECX-006D
Connector(Vertical)
ECX-006E
All specifications are subject to change without notice.
A131_ECX
(13/21)
TDK Switching Power Supply
E SERIES ECX-006
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-006
M4×8
4-M3 Screw tap
5 0.3
150 0.7
(5)
(5.6) 25.4max.
(for mounting, rear view)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
160 1
5 0.3
150 0.7
(5)
2-M3 Screw tap
(for mounting)
UP
(
): for reference dimensions
All specifications are subject to change without notice.
A131_ECX
(14/21)
TDK Switching Power Supply
E SERIES ECX-007
SPECIFICATIONS AND STANDARDS
PART NO.
ECX-007
Rated output voltage
and current∗1
V1
V2
W
5V • 3A
24V • 6A(Peak current 10A)
159[Peak current output: 255]
Maximum output power
INPUT CONDITIONS
Input voltage∗6 Eac
Input frequency
Input current
V
85 to 115[Rating: 100](The input range of 170 to 253[Rating: 200] is possible by internal switching.)
Hz
A
47 to 66[Rating: 50 to 60](Single phase)
5max.[25°C, input and output ratings]
Fuse rating
A
8[Built-in]
Surge current∗2
Leakage current
Efficiency
A
50max.[25°C, input and output ratings.]1st surge current, reset after 30s minimum.
mA
%
1max.[25°C, input and output ratings]
85typ.
OUTPUT CHARACTERISTICS
Output voltage Edc
Voltage variable range Edc
Maximum output current
Minimum output current
Input variation
V
5(V1)
24(V2)
V
Fixed
Fixed
A
3
6(Peak current 10A, 10s max.)
A
0
0
%
1max.
3.5max. [Within the input voltage range]
Load variation∗3
%
2max.
8max.
2max.
[V2: 10 to 100%]
∗4 Total variation 5max.(24V: 10max.)
Voltage
stability
Temperature variation
%
1max.
[0 to +40°C]
Drift
%
0.5max.
1.5max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Dynamic load
Ripple∗4 Ep-p
Ripple noise∗4 Ep-p
V/ms
mV
mV
s
—
2.4(Voltage variation)/5(Reset time)[1 to 10A sudden load change]
100max.
600max.
800max.
150max.
Start up time
1.5max.(Rise time: 20ms max.)
20min.
Normal temperature, input and output ratings,
load capacitance 100µF max.
Hold up time
ms
AUXILIARY FUNCTIONS
Indicator display
No
Only V1 protected by built-in overvoltage prevention switch inhibition. Recovery when input reset
(restart requires roughly 5min wait).
Overvoltage protection
Overcurrent protection∗6
Remote ON-OFF
Remote sensing
Current balance
STANDARDS
Upon overcurrent detection, outputs are lowered and winker operates.
No
No
No
Safety standards
Noise terminal voltage
CONSTRUCTIONS
External dimensions
Weight
—
—
mm
g
35×95×220[H×W×L]
700max.
Mounting method
Case material
Can be attached to 2 sides.
Frame: Aluminum plating(without cover)
Input and output cables
—
∗1 The rated output current is determined at 40°C. Use it with a load rate of 75% for 50°C and 50% for 60°C.
The V2 peak current should be limited to 10 sec max. and the effective current should be used at the rated current or lower.
∗2 A power thermistor is used as a surge current suppressing element.
∗3 Determined within a range of 10 to 100% load variations.
∗4 If the variation for the V2 output is 10% or lower, the V2 output voltage is 30V max.
∗5 Ripple and noise were determined for 0 to +40°C ambient temperature range and at the rated input/output value.
∗6 It is set to input 200V at delivery. For a use at 100V, connect an attached connector. Be careful, however, that the power supply is damaged if it is
connected to input 200V with the connector for the 100V use being connected.
∗7 The output overcurrent protection is effective only for a short circuit.
PRODUCT IDENTIFICATIONS
Input and output style
Terminal block
L-shape frame type
ECX-007D
Connector(Vertical)
ECX-007E
All specifications are subject to change without notice.
A131_ECX
(15/21)
TDK Switching Power Supply
E SERIES ECX-007
Dimensions in mm
SHAPES AND DIMENSIONS
ECX-007
M4×8
4-M3 Screw tap
5 0.3
210 0.7
(5)
(7.6)
28.4max.
(for mounting, rear view)
+
24V
5V
–
output
+
–
G
L
input
N
4-Length of installation screw
8max.
220 1
5 0.3
103.5 0.7
106.5 0.7
(5)
4-M3 Screw tap
(for mounting)
UP
15 0.3
(
): for reference dimensions
All specifications are subject to change without notice.
A131_ECX
(16/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
BLOCK DIAGRAM
ECX-001/-003
G
Surge
current
limiting
circuit
Input
filter
circuit
Input
smoothing
circuit
+
L
N
Output
rectifying
and
smoothing
circuit
V2:24V
–
100V/200V
Change-over
connector
Over-
Power
switching
circuit
+
Output
rectifying
and
smoothing
circuit
current
detection
circuit
V1:5V
–
Series
regulator
Voltage detection
circuit
Control
circuit
Control
circuit
• V1 and V2 outputs are floating.
ECX-002/-004
G
Surge
current
limiting
circuit
Input
smoothing
circuit
Output rectifying
and
smoothing circuit
Input
filter
circuit
+
L
N
V2:24V
V1:5V
–
100V/200V
Over-
Power
switching
circuit
current
detection
circuit
Change-over
connector
Output rectifying
and
smoothing circuit
+
–
Overcurrent
detection
circuit
Control
circuit
Control
circuit
Over-
voltage
detection
circuit
• V1 and V2 outputs are floating.
All specifications are subject to change without notice.
A131_ECX
(17/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
ECX-005/-006/-007
G
Surge
current
limiting
circuit
Input
smoothing
circuit
Output rectifying
and
smoothing circuit
Input
filter
circuit
+
L
N
V2:24V
–
100V/200V
Over-
Power
switching
circuit
Change-over
connector
current
detection
circuit
Output rectifying
and
smoothing circuit
+
V1:5V
–
Overcurrent
detection
circuit
Control
circuit
Control
circuit
Over-
• V1 and V2 outputs are floating.
voltage
detection
circuit
COMMON SPECIFICATIONS
Temperature and humidity
Operating(°C)
Storage(°C)
0 to +60 Derating is necessary when operating environment temperature exceed 40°C
–25 to +75
.
Temperature range
Operating(%)RH
Storage(%)RH
Humidity range
20 to 95[Maximum wet-bulb temperature: 35°C, without dewing]
Amplitude and vibration
5 to 10Hz
All amplitude 10mm[3 directions, each 1h]
Acceleration 39.2m/s2[4G, 3 directions, horizontal installation, each 1h]
Amplitude
10 to 200Hz
Acceleration 19.6m/s2[2G, 3 directions, vertical installation, each 1h]
Acceleration
392m/s2[40G, 3 directions, each 3 times]
11 5ms
Vibration
Vibration time
Withstand voltage and insulation resistance
Input terminal to ground terminal(
Input terminal to output terminal
Input terminal to ground terminal(
Input terminal to output terminal
)
Eac(kV)1.5, 1min[Normal temperature, normal humidity, cutout current 10mA]
Eac(kV)2, 1min[Normal temperature, normal humidity, cutout current 10mA]
G
Withstand voltage
)
G
Insulation resistance
Edc(V)500, 100MΩ min. [Normal temperature, normal humidity]
Output terminal to ground terminal(
)
G
All specifications are subject to change without notice.
A131_ECX
(18/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
TERMINAL DESIGNATIONS AND FUNCTIONS
ECX-001/002
1
AC input terminals(L, N)
Connected to either the
AC.100V or 200V single-phase
line. The delivery setting is
200V. Before use with these
terminals connected to 100V,
connect the attached connector
to CP2.
1
2
3
4
5
6
7
1
3
5
24V+
24V+
24V–
NC
4
5
3
+
1
24V
5V
4
2
3
4
5
6
7
4
5
3
Reference:
Corresponding housing
XHP-7(JST)
Corresponding contact
SXH-001T-P0.6
–
+
–
Output
connector
3
2
1
5V+
5V–
5V–
G
2
3
4
5
6
Frame ground terminal(G)
Connect to earth ground.
1
3
5
2
1
G
L
DC output terminals(5V, +, –)
Connect to load.
Reference:
Corresponding housing
VHR5N(JST)
Corresponding contact
SVH-21T-P1.1
2
1
DC output terminals(24V, +, –)
Connect to load.
N
Input
connector
L
CP2
No connection(NC)
Connect none to this terminal.
N
Input switching connector
6
(CP2)
For use in switching AC input
voltages.
Without CP2 connector: For
200V use
With CP2 connector: For 100V
use
ECX-003/004/005/006
1
AC input terminals(L, N)
Connected to either the
AC.100V or 200V single-phase
line. The delivery setting is
200V. Before use with these
terminals connected to 100V,
connect the attached connector
to CP2.
1
2
3
4
5
6
1
3
5
24V+
24V+
4
3
+
–
+
–
Reference:
1
24V
5V
4
2
3
4
5
6
4
3
24V– Corresponding housing
Output
connector
VHR-6N(JST)
Corresponding contact
SVH-21T-P1.1
5V+
5V–
5V–
G
3
2
1
2
3
4
5
Frame ground terminal(G)
Connect to earth ground.
1
3
5
2
1
G
L
DC output terminals(5V, +, –)
Connect to load.
Reference:
Corresponding housing
VHR-5N(JST)
Corresponding contact
SVH-21T-P1.1
2
1
Input
connector
L
DC output terminals(24V, +, –)
Connect to load.
N
N
Input switching connector
(CP2)
For use in switching AC input
voltages.
5
Without CP2 connector: For
200V use
With CP2 connector: For 100V
use
All specifications are subject to change without notice.
A131_ECX
(19/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
ECX-007
+
–
+
–
1
2
3
4
5
6
7
24V
5V
4
4
3
3
2
1
1
3
5
2
1
G
L
N
5
CP2
1
AC input terminals(L, N)
1
2
3
4
5
6
7
1
3
5
24V+
24V+
24V–
24V–
5V+
5V–
5V–
G
Connected to either the AC.100V or 200V single-
phase line. The delivery setting is 200V. Before use
with these terminals connected to 100V, connect the
attached connector to CP2.
4
Reference:
Corresponding housing
VHR-7N(JST)
Corresponding contact
SVH-21T-P1.1
Output
connector
2
3
4
5
Frame ground terminal(G)
Connect to earth ground.
DC output terminals(5V, +, –)
Connect to load.
3
DC output terminals(24V, +, –)
Connect to load.
Input switching connector(CP2)
For use in switching AC input voltages.
Without CP2 connector: For 200V use
With CP2 connector: For 100V use
Reference:
Corresponding housing
VHR-5N(JST)
Corresponding contact
Corresponding contact
2
1
Input
connector
L
N
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)
INPUT SURGE CURRENT, START UP TIME AND HOLD UP
TIME
Example: ECX-001
Input voltage: AC.100V
Load: Rating
100
80
75
Temperature: 25°C
∗ ECX-007 causes a second peak.
60
50
Input surge current∗
15A(30A at 200V)
40
Available operating range
(outside of warranty)
20
–10
0
10
20
30
40
50
60
24V output
Input ON
Ambient temperature(°C)
5V output
10ms
Rise time
Start up time 750ms
37 to 42ms
15 to 20ms
Fall time
Hold up time
All specifications are subject to change without notice.
A131_ECX
(20/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
OUTPUT CHARACTERISTICS(TYPICAL EXAMPLE SHOWN
BELOW.)
ECX-001(24V)[25°C, INPUT AND OUTPUT RATINGS]
ECX-001(5V)[25°C, INPUT AND OUTPUT RATINGS]
6
28
26
24
22
20
5V/1A
5V/0A
24V=1A
5V/0A
5
24V=0A
4
5V/1A
3
2
1
0
10
0
1
2
3
1
2
3
4
Output current(A)
Output current(A)
ECX-007(24V)[25°C, INPUT AND OUTPUT RATINGS]
ECX-007(5V)[25°C, INPUT AND OUTPUT RATINGS]
6
28
26
24
22
20
5V/3A
24V=0A
5
24V=6A
4
5V/0A
3
2
1
0
10
0
1
5
6
10
1
2
3
4
5
6
Output current(A)
Output current(A)
DYNAMIC LOAD(TYPICAL EXAMPLE SHOWN BELOW.)
ECX-001[AC: 100V, 25°C]
ECX-007[AC: 100V, 25°C]
(1.5A)
(10A)
Current(0A)
Current(0A)
Voltage
Voltage
V:0.5V/DIV, 1A/DIV(0↔1.5A) H:5ms/DIV
5V→1A
V:1V/DIV, 5A/DIV(0↔10A) H:2ms/DIV
5V→3A
All specifications are subject to change without notice.
A131_ECX
(21/21)
TDK Switching Power Supply
Characteristics, Functions, and Applications
ABOUT 24V (V2) OUTPUT PEAK CURRENT
INPUT VOLTAGE
The ECX-001, ECX-003, ECX-005, and ECX-007 are capable of
flowing peak current as 24V load current for driving mechatronics.
The values exceeding the continuous rated values, however,
The output of the power supply may shut down upon a
continuous input of 30% to 50% of the input rated voltage applied
for approx. 1 sec or longer. Output recovers by reentry of an input
(approx. 5 min. needed before the reentry of the input).
must fulfill the following conditions.
I1
TONE GENERATION
A little tone may be generated in an unloaded condition for all
outputs. It is, however, not an abnormal condition.
I2
INPUT FILTER
The power supply has an input line filter mounted inside in order
to reduce external noise or to prevent a noise generated inside
the power supply from adversely affecting external electronic
equipment. Ground wiring is recommended for the G terminal
(frame) in order to enhance the filter effect. If a further noise
reduction is required, attach a filter to a portion outside the power
supply.
t
T
D=(t/T)
1 Condition of time
10s
3 Conditions of effective current
t
2
2
2
2
2
DI1 +(I–D)I2
1A(ECX-001)
1.5A(ECX-003)
3A(ECX-005)
6A(ECX-007)
2 Conditions of current value
I1 1.5A(ECX-001)
I1 3A(ECX-003)
2
DI1 +(I–D)I2
2
DI1 +(I–D)I2
2
DI1 +(I–D)I2
I1 5A(ECX-005)
LEAKAGE CURRENT
I1 10A(ECX-007)
Leakage current flows between the G terminal (frame) and the
ground. If two or more power supplies are used or a filter is
attached to an external portion, the total leakage current is
applied.
NOTES ON USE
INTERNAL ADJUSTMENT TRIMMER
This product has an internal adjustment trimmer. Please do not
touch it that can result in damage caused by any change of the
setting.
RIPPLE NOISE MEASUREMENT
Measure the ripple noise as shown below.
C1, C2 : 0.1µF
: Film capacitor
C3: 100µF
: Electrolytic capacitor
Approx.15cm
OVERCURRENT PROTECTION FUNCTION
The output overcurrent protection is effective only for a short
circuit. A continuation of the intermediate overload condition (for
example, if the condition continues for a time period exceeding
the standard at the peak current value) may cause a damage on
the product.
+
Power
supply
R1: 50Ω resistor
Input
Output C3 C2
Load
50Ω coaxial cable
R1
C1
HANDLING PRODUCT BEING ENERGIZED (INCLUDING
IMMEDIATELY AFTER BEING ENERGIZED)
Oscilloscope band
width<50MHz
There are some high-temperature or high-voltage portions inside
the power supply being energized (or immediately after being
energized). Be careful to touch internal components. In addition,
energizing at light load may leave a high voltage for several
minutes after a shutdown of the input voltage.
MAINTENANCE SERVICE
In case of a trouble, do not make any adjustment on the inside of
the power supply. Otherwise, the product may not be guaranteed.
In case of a trouble in the product, please return it to us through a
purchasing route. If there are any unclear points for use of the
power supply, please contact us.
POWER SUPPLY INSTALLATION METHOD
For installation with frame
A vertical installation
OTHERS
Frame
B horizontal installation
.
1 Unless conditions are otherwise specified in the specifications
Cabinet
or standards, 25°C and rated input-output should be applied.
2. Surface treated steel sheets are used for a frame and a part of
a radiator in this product. Although rust may be gathered on
their cross sections, they can be used as they are. Note that,
however, the product should be put in for repair in case of a
significant deterioration of the rust or a damaged insulation
1. For an open frame type, use spacers or the like to make a clearance from the
cabinet. In using non-insulated spacers, use ones having a 6mm external
diameter.
2. The vibration, shock, and conditions depend upon the power supply
installation method. For details, refer to descriptions of the corresponding
items.
property because of a use bad environments.
A131_ECX
020826
All specifications are subject to change without notice.
相关型号: