AC/DC Front End  
FPS SERIES  
FPS  
Y
E
A
R
2
S
warranty  
■ Features  
Power Supply Identification  
FPS 1000 - 48 /PS  
ꢀ● Compact, 1U high, and, high power density  
Size: 127(W)×41(H)×290(D) mm  
3
Power Density: 11W/inch ,  
Senes O/P Power O/P Voltage Option  
Maximum Output Power: 1kW  
ꢀ● Universal Input: AC85-265V  
1000(W)  
3000(W)  
12(V)  
24(V)  
48(V)  
Blank: Standard Model  
/P : IEC Inlet Type (on front panel)  
/S : I²C Opton built-in  
ꢀ● Up to 3000W (3 units) in 19"rack  
ꢀ● Hot swap / N+1 redundant parallel operation available  
/PS : IEC inlet +I²C Option  
2
ꢀ● I C option available (/S, /PS model)  
Note: FPS3000 is 3x FPS + FPS-S1U in one rack.  
FPS3000 can include 3x FPS with same ratings.  
ꢀ● Front IEC inlet model (AC input) available,  
(/P, /PS model)  
FPS-S1U /PS  
Senes Option  
■ Applications  
Blank: Standard Model  
(For FPS1000-*, FPS1000-*/S)  
/P : IEC Inlet Type (on front panel,  
for FPS1000-*/P, FPS1000-*/PS)  
Note: FPS-S1U does not have FPS1000. This is 1U rack  
only. Up to 3x FPS1000 (with same voltage rating)  
can be installed into FPS-S1U.  
■ Product Line up  
1000W  
Output Voltage  
Output Current  
Model  
12V  
24V  
48V  
72A  
40A  
21A  
FPS1000-12  
FPS1000-24  
FPS1000-48  
Conformity to RoHS Directive  
This means that, in conformity with EU Directive 2002/95/  
EC, lead, cadmium, mercury, hexavalent chromium, and  
specific bromine-based flame retardants, PBB and PBDE,  
have not been used, except for exempted applications.  
FPS3000 - □  
Shelf type: 3 units of FPS1000 mounting in a 19-inch  
shelf (FPS-S1U) with maximum 3kW  
Size: 440(W)×43.6(H)×351(D) mm  
All specifications are subject to change without notice.  
A-47  
FPS1000  
FPS1000 Specifications  
MODEL  
(*1)  
(*1) Hz  
FPS1000-12  
FPS1000-24  
FPS1000-48  
ITEMS/UNITS  
Voltage Range  
V
AC85 - 265 continuous (Universal input)  
Frequency  
47 - 63, single phase  
Power Factor (115/230VAC)(typ)  
Input Efficiency (typ) (*2) %  
Current (100/200VAC) (max)  
More than 0.98 at maximum output power  
81 / 83  
84 / 86  
12.0 / 6.0  
Less than 40  
Less than 1.1  
24  
85 / 88  
A
A
Inrush Current  
(*3)  
Leakage Current (230VAC)  
Nominal Voltage  
mA  
VDC  
A
12  
72  
48  
21  
FPS  
Maximum Current  
Maximum Power  
(*Fig.1)  
40  
W
864  
960  
1008  
Voltage Set Point  
12V +/-1%  
24V +/-1%  
0.40%  
48V +/-1%  
Maximum Line Regulation(*5)  
Output Maximum Load Regulation(*6)  
Temperature Coefficient  
Warm Up Drift  
0.80%  
200PPM/℃  
0.1% of rated Vout for 8hrs after 30min warm-up. Constant line, load and temperature.  
150 200 300  
20 at rated output voltage and less than 80% of rated load.  
Maximum Ripple & Noise (*4) mVp-p  
Hold-up Time (100VAC)(typ) ms  
Voltage Adjustable Range  
VDC  
10.5 - 13.2  
21.5 - 29  
43 - 58  
Over Current Protection(*Fig.1)  
105 - 125% of maximum output current.  
31 - 34  
Over Voltage Protection (*8) VDC  
Over Temperature Protection  
14.3 - 15.7  
62 - 66  
Inverter shut down method, automatic reset.  
Possible. Refer to instruction manual.  
Remote Sensing  
(*7)  
Remote ON/OFF Control  
Parallel Operation  
Series Operation  
By electrical signal or dry contact. ON: 0 - 0.6V or short. OFF: 2 - 15V or open.  
Possible. Refer to instruction manual.  
(*9)  
(*10)  
Possible. Refer to instruction manual.  
Function  
Over Temperature Alarm Signal  
DC OK signal  
Open collector signal. Normal: ON, Max.sink current: 10mA.  
Open collector signal. On when Vout>80+/-5% rated output. Max.sink current: 10mA  
Open collector signal. On when Vin > 85VAC, Max.sink current: 10mA.  
11.2 - 12.5VDC. 0.25A maximum output current.  
Possible, via Vout trim pin in the I/O connector. Refer to instruction manual.  
AC OK, DC OK, DC FAIL  
AC Fail Signal  
AUX-BIAS Power Supply  
Output Voltage Trimming  
Front Panel Indicators  
I²C Interface  
Optional. Refer to instruction manual.  
Operating Temperature  
Storage Temperature  
Operating Humidity  
RH  
RH  
0 to 50: 100% load. Derate 2%/, 50 to 60  
-30 to 85  
10 - 90, no condensation.  
Environment Storage Humidity  
Vibration  
10 - 95, no condensation.  
Built to meet ETS 300 019  
Shock  
Built to meet ETS 300 019  
Cooling  
By internal fans. Variable speed control.  
Withstand Voltage  
Isolation  
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground: 500Vrms, 1min.  
More than 100Mohm at 25and 70% RH. Output-Ground: 500VDC  
Approved by UL60950-1, EN60950-1, CSA C22.2 No.60950-1  
EN55022B, FCC part 15J-B, VCCI-B  
Isolation Resistance  
Safety Standards  
Standards  
EMI  
(*11)  
Weight (typ)  
Mechanical  
g
2000  
Size (W x H x D)  
mm  
127 x 41 x 290 (Refer to outline drawing.)  
(*1) For cases where conformance to various safety standards (UL, EN etc.)  
is required, to be described as 100-240Vac (50/60Hz).  
Vout (V)  
(*2) At 100/200VAC, rated load and 25ambient temperature.  
(*3) Not applicable for the noise filter inrush current less than 0.2ms.  
(*4) Measured with JEITA RC-9131 1:1 probe, 20MHz B.W.  
(*5) From 85-132Vac or 170-265VAC, constant load.  
V2  
V1  
(*6) From no-load to rated load, constant input voltage.  
Model  
V1  
FPS1000 FPS1000 FPS1000  
Measured at the sensing point in remote sense.  
-12  
12V  
-24  
24V  
29V  
33A  
40A  
-48  
(*7) Remote sensing can compensate up to 1V drop on  
each load wire.  
V1  
V2  
l1  
48V  
58V  
(*8) Inverter shut down method. Reset by AC voltage  
recycle or by ON/OFF control.  
13.2V  
66A  
72A  
17.25A  
21A  
(*9) Derate maximum output power by 10% for input  
l2  
.
voltage less than 100VRMS  
(*10) Series operation is not applicable for units  
with I2C bus option (/S, /PS model).  
l1  
l2  
Iout(A)  
Fig.1 Rated output current vs rated output voltage  
(*11) For FPS 1000-12/P(S), when used not with FPS-S1U or FPS-T1U  
racks, an EMI suppressor clamp should be attached to the AC cable,  
as close as possible to the AC inlet, to meet class B.  
All specifications are subject to change without notice.  
A-48  
FPS 1000  
Outline Drawing  
FPS1000  
FRONT VIEW  
SEE NOTE 4  
SEE NOTE 2  
REAR VIEW  
FPS  
IN/OUT CONNECTOR  
SEE NOTE 1  
NOTES  
AIR FLOW  
1. CONNECTOR TYPE: PCIB24W9M400A1, POS- DIRECTION  
ITRONIC. FEMALE CONNECTOR TYPE: PCIB-  
24W9F400A1,-S1031(not attached with unit)  
2. LED INDICATORS. REFER TO INSTRUCTION  
MANUAL.  
3. MOUNTING SCREWS MUST NOT PENETRATE  
MORE THAN 3mm INTO THE UNIT.  
4. MODEL NAME, INPUT AND OUTPUT RATING  
AND SAFETY APPROVALS SYMBOLS ARE  
DESCRIBED ON TOP SURFACE LABEL.  
5. ALLOW MINIMUM 50mm OF UNRESTRICTED  
3 MOUNTING HOLES M3 MARKED "A" SEE NOTE 3  
(unit: mm)  
PIN  
PIN  
PIN  
AIR SPACE AT THE REAR OF UNIT. DO NOT  
OBSTRUCT AIR FLOW TO THE UNIT FRONT  
PANEL.  
1
2
3
4
5
6
7
8
9
19  
20  
21  
23  
FUNCTION  
FUNCTION  
DC_OK  
SIGNAL_RTN  
AC_FAIL  
TEMP_ALARM  
-S  
V_TRIM  
CS  
+12V_AUX  
FUNCTION  
NUMBER.  
NUMBER.  
9
NUMBER.  
24  
22  
2
1
2
3
4
5
6
7
8
+v  
+v  
-v  
+v  
-v  
17  
18  
19  
20  
21  
22  
23  
24  
SDA (I C)  
2
10  
11  
12  
13  
14  
15  
16  
SCL (I C)  
2
A0 (I C)  
2
6. IN OUT CONNECTOR BACK VIEW AND PINS  
ASSIGNMENT:  
A1 (I C)  
2
A2 (I C)  
-v  
ACG  
ACL  
ACN  
ON/OFF  
+S  
FPS1000/P  
FRONT VIEW  
SEE NOTE 4  
SEE NOTE 2  
IEC320  
AC INLET  
REAR VIEW  
OUTPUT CONNECTOR SEE NOTE 1  
AC CABLE  
LOCK OPTION  
AIR FLOW  
DIRECTION  
NOTES  
1. CONNECTOR TYPE: PCIB24W9M400A1, PO-  
SITRONIC. FEMALE CONNECTOR TYPE:  
PCIB24W9F400A1,-S1031(not attached with  
unit)  
2. LED INDICATORS. REFER TO INSTRUCTION  
MANUAL.  
3. MOUNTING SCREWS MUST NOT PENETR-  
ATE MORE THAN 3mm INTO THE UNIT.  
4. MODEL NAME, INPUT AND OUTPUT RATING  
AND SAFETY APPROVALS SYMBOLS ARE  
DESCRIBED ON TOP SURFACE LABEL.  
5. ALLOW MINIMUM 50mm OF UNRESTRICTED  
AIR SPACE AT THE REAR OF UNIT. DO NOT  
OBSTRUCT AIR FLOW TO THE UNIT FRONT  
PANEL.  
3 MOUNTING HOLES M3 MARKED "A" SEE NOTE 3  
(unit: mm)  
PIN  
PIN  
PIN  
1
2
3
4
5
6
7
8
9
19  
20  
21  
23  
FUNCTION  
FUNCTION  
DC_OK  
SIGNAL_RTN  
AC_FAIL  
TEMP_ALARM  
-S  
V_TRIM  
CS  
+12V_AUX  
FUNCTION  
NUMBER.  
NUMBER.  
9
NUMBER.  
24  
22  
2
1
2
3
4
5
6
7
8
+v  
+v  
-v  
+v  
-v  
-v  
17  
18  
19  
20  
21  
22  
23  
24  
SDA (I C)  
2
10  
11  
12  
13  
14  
15  
16  
SCL (I C)  
2
A0 (I C)  
2
A1 (I C)  
2
A2 (I C)  
NC  
NC  
NC  
6. IN OUT CONNECTOR BACK VIEW AND PINS  
ASSIGNMENT:  
ON/OFF  
+S  
All specifications are subject to change without notice.  
A-49  
FPS-S1U  
FPS-S1U Specifications  
MODEL  
(*2)  
(*2) Hz  
FPS-S1U  
ITEMS/UNITS  
Voltage Range  
Input Frequency  
Current (100/200VAC)(max)  
Output Maximum Power (*1)  
V
AC85 - 265 continuous (Universal input)  
47 - 63, Single phase  
A
12.0 / 6.0 for each FPS1000 unit installed  
3000  
W
Remote Sensing  
(*3)  
Possible.  
Separate control for each FPS1000 unit, by electrical signal or dry contact.  
On: 0 - 0.6V or short. OFF: 2 - 15V or open.  
Possible.  
Remote ON/OFF Control  
FPS  
Parallel Operation  
Series Operation  
Over Temperature Alarm  
Signal  
(*6)  
(*4)  
Possible. Up to 2 racks of the same voltage and current rating.  
Separate control for each FPS1000 unit, open collector signal.  
Normal: ON, max.sink current: 10mA  
Separate control for each FPS1000 unit, open collector signal.  
On when Vout>80%+/-5% max.sink current: 10mA  
Separate control for each FPS1000 unit, open collector signal.  
On when Vin > 85VAC, max.sink current: 10mA.  
11.2 - 12.5VDC. Maximum output current: 0.25A x Number of installed FPS1000 units.  
Possible. Refer to instruction manual.  
Function DC OK Signal  
AC Fail Signal  
AUX-BIAS Power Supply  
Output Voltage Trimming  
AC Input Connector  
Output Terminals  
FPS-S1U: IEC inlet for each power supply module. FPS-S1U/P: None  
Bus-bars. Refer to outline drawing.  
Number of Power Supply Modules (*5)  
Operating Temperature  
Storage Temperature  
Operating Humidity  
Storage Humidity  
Vibration  
Maximum 3 FPS1000 modules of the same output voltage rating.  
0 to 50: 100% load. Derate 2%/, 50 to 60.  
-30 to 85  
RH  
RH  
10 - 90, no condensation.  
Environment  
10 - 95, no condensation.  
Built to meet ETS 300 019  
Shock  
Built to meet ETS 300 019  
Withstand Voltage  
Isolation Resistance  
Input-Output: 3000Vrms, 1min. Input-Ground: 2000Vrms, 1min. Output-Ground: 500Vrms, 1min.  
More than 100MΩ at 25and 70% RH. Output-Ground: 500VDC  
UL60950-1, EN60950-1, CSA C22.2 No.60950-1  
3700  
Isolation  
Standards Safety Standards  
Weight (typ)  
Mechanical  
g
Size (W x H x D)  
mm  
440 x 44 x 351 (Refer to outline drawing.)  
(*1) For input voltage lower than 100VAC, maximum output power is 2700W.  
(*2) For cases where conformance to various safety standards (UL, EN etc.) is required, to be described as 100-240VAC (50/60Hz).  
(*3) Remote sensing can compensate up to 1V drop on each load wire.  
(*4) Not applicable for units with I2C bus option.  
(*5) The output of all the FPS1000 modules are connected in parallel in the rack.  
(*6) Up to 3 racks with max.8 FPS1000 units of the same voltage and current rating.  
All specifications are subject to change without notice.  
A-50  
FPS-S1U  
Outline Drawing  
SIGNAL & CONTROL  
FPS-S1U  
CONNECTOR D-TYPE 25 PINS  
I2C INTERFACE  
ADDRESS SWITCH  
(SEE NOTE 3)  
OUTPUT  
BUS BAR  
MODULE "A"  
MODULE "B"  
MODULE "C"  
SIDE MOUNTING HOLES  
MARKED "D" 3 ON EACH SIDE  
(SEE NOTE 5.)  
SEE NOTE 1.  
SEE NOTE 2.  
FPS  
HOLES FOR BLANK PANEL  
MOUNTING: USE FLAT  
HEAD SCREWS M3x6- 6  
PLACES MARKED "A"  
UNIT : mm  
NOTES  
(*1)ꢀMOUNTING HOLES FOR 19" RACK, USE M6x12 TO FIX THE UNIT  
TO A RACK.ꢀ  
APPROVALS SYMBOLS WILL BE SHOWN HERE ACCORDING TO  
THE SPECIFICATIONS.  
(*5)ꢀMOUNTING HOLES M5 FOR MOUNTING BRACKETS . USE M5x8  
SCREWS TO FIX THE BRACKETS TO THE CHASSIS. SCREWS  
MUST NOT PENETRATE THE CHASSIS MORE THAN 6 mm.  
(*6)ꢀTHE FPS-S1U RACK IS SHOWN WITH 3 FPS1000 UNITS  
INSTALLED.  
(*2)ꢀM6x16 SCREWS FOR LOAD WIRES FIXING, USE M6 LUG FOR  
THE LOAD WIRES, RECOMMENDED TIGHTENING TORQUE 42 - 56  
Kgf.cm  
(*3)ꢀREFER TO INSTRUCTION MANUAL FOR SETTING DETAILS.  
(*4)ꢀMODEL NAME , VOLTAGE AND CURRENT RATING AND SAFETY  
SIGNALS & CONTROL CONNECTOR PINS ASSIGNMENT  
CONNECTOR DESCRIPTION:  
13  
1
D-TYPE RIGHT ANGLE, 25 POSITIONS,  
FRONT METAL SHELL,  
OUTPUT TERMINAL COVER.  
INSTALL AFTER LOAD  
25  
14  
AMP P/N: 747846-4  
CABELS CONNECTION.  
PIN NUMBER.  
9
10  
11  
12  
13  
14  
15  
16  
FUNCTION  
PIN NUMBER.  
FUNCTION  
V_TRIM_B  
TEMP_ALARM_B  
DC_OK_B  
TEMP_ALARM_A  
ON/OFF_A  
DC_OK_A  
PIN NUMBER.  
17  
18  
19  
20  
21  
22  
23  
24  
FUNCTION  
CS  
FLAT HEAD  
SCREW M3x6  
-2 PLACES-  
1
2
3
4
5
6
7
8
NC  
NC  
NC  
SEE NOTE 4  
V_TRIM_C  
SIGNAL_RTN  
DC_OK_C  
+S  
AC_FAIL_B  
ON/OFF_B  
AC_FAIL_A  
SCL(l2C)  
SDA(l2C)  
-S  
TEMP_ALARM_C  
AC_FAIL_C  
ON/OFF_C  
V_TRIM_A  
+12V_AUX  
25  
PS MODULE "A"  
BLANK PANEL  
PS MODULE "B"  
INFORMATION:  
(OPTIONAL)  
ORDER NAME: FPS-BP  
PS MODULE "C"  
UNIT : mm  
AIR FLOW  
DIRECTION  
All specifications are subject to change without notice.  
A-51  
FPS-S1U/P  
SIGNAL & CONTRO  
FPS-S1U / P  
CONNECTOR D-TYP 25 PINS  
I2C INTERFACE  
ADDRESS SWITCH  
(SEE NOTE 3.)  
OUTPUT  
BUS BAR  
SIDE MOUNTING HOLES  
MARKED "D" 3 ON EACH SIDE  
(SEE NOTE 5.)  
SEE NOTE 1.  
SEE NOTE 2.  
FPS  
HOLES FOR BLANK PANEL  
MOUNTING: USE FLAT  
HEAD SCREW M3x6-  
6PLACES MARKED "A"  
UNIT : mm  
NOTES  
(*1)ꢀMOUNTING HOLES FOR 19" RACK, USE M6x12 TO FIX THE UNIT  
TO A RACK.ꢀ  
(*3)ꢀREFER TO INSTRUCTION MANUAL FOR SETTING DETAILS.  
(*4)ꢀMODEL NAME , VOLTAGE AND CURRENT RATING AND SAFETY  
APPROVALS SYMBOLS WILL BE SHOWN HERE ACCORDING TO  
THE SPECIFICATIONS.  
(*5)ꢀMOUNTING HOLES M5 FOR MOUNTING BRACKETS . USE M5x8  
SCREWS TO FIX THE BRACKETS TO THE CHASSIS. SCREWS  
MUST NOT PENETRATE THE CHASSIS MORE THAN 6 mm.  
(*6)ꢀTHE FPS-S1U/P RACK IS SHOWN WITH 3 FPS1000/P UNITS  
INSTALLED.  
(*2)ꢀM6x16 SCREWS FOR LOAD WIRES FIXING. USE M6 LUG FOR THE  
LOAD WIRES. RECOMMENDED TIGHTENING TORQUE 42 - 56  
Kgf.cm  
SIGNALS & CONTROL CONNECTOR PINS ASSIGNMENT  
CONNECTOR DESCRIPTION:  
D-TYPE RIGHT ANGLE, 25 POSITIONS,  
FRONT METAL SHELL.  
13  
1
25  
14  
AMP P/N: 747846-4  
OUTPUT TERMINAL COVER.  
INSTALL AFTER LOAD  
CABLES CONNECTION.  
PIN NUMBER.  
FUNCTION  
V_TRIM_B  
PIN NUMBER.  
9
10  
11  
12  
13  
14  
15  
16  
FUNCTION  
PIN NUMBER.  
17  
18  
19  
20  
21  
22  
23  
24  
FUNCTION  
1
2
3
4
5
6
7
8
CS  
NC  
NC  
NC  
TEMP_ALARM_B  
DC_OK_B  
V_TRIM_C  
SIGNAL_RTN  
DC_OK_C  
+SENSE  
AC_FAIL_B  
ON/OFF_B  
AC_FAIL_A  
SEE NOTE 4  
2
TEMP_ALARM_A  
ON/OFF_A  
SCL(I C)  
FLAT HEAD  
SCREW M3x6  
-2 PLACES-  
2
SDA(I C)  
DC_OK_A  
-SENSE  
V_TRIM_A  
TEMP_ALARM_C  
AC_FAIL_C  
ON/OFF_C  
+12V_AUX  
25  
PS MODULE "A"  
BLANK PANEL  
INFORMATION:  
(OPTIONAL)  
PS MODULE "B"  
ORDER NAME: FPS-BP  
AIR FLOW  
DIRECTION  
PS MODULE "C"  
UNITS:mm  
All specifications are subject to change without notice.  
A-52  

相关型号:

FPS1000-12/PS

AC-DC电源
TDK

FPS1000-12/S

AC-DC电源
TDK

FPS1000-24

AC/DC Front End
TDK

FPS1000-24-P

AC-DC Power Supplies
TDK

FPS1000-24-PS

AC-DC Power Supplies
TDK

FPS1000-24-S

AC-DC Power Supplies
TDK

FPS1000-24/P

AC-DC电源
TDK

FPS1000-24/PS

AC-DC电源
TDK

FPS1000-24/S

AC-DC电源
TDK

FPS1000-32

AC-DC电源
TDK

FPS1000-32/P

AC-DC电源
TDK

FPS1000-32/PS

AC-DC电源
TDK