LZSA Series  
https://product.tdk.com/en/power/lzsa  
500-1500W Industrial Power supplies  
www.emea.lambda.tdk.com/lzsa  
The LZSA series offers a unique feature set not commonly found with standard off-the-shelf supplies. Compliance to the MIL-STD-810E standards for shock  
and vibration and board coating make the LZSA power supplies ideal for use in a variety of harsh environment applications. They also comply with the tough  
ring wave lightning surge test per IEEE C62.41. Features include remote on/off, remote sense, frequency synchronization and a wide operating temperature  
range of -40°C to +71°C. The series also has a wide adjustment range which can be programmed using an external voltage or resistance.  
Features  
Benefits  
• Rugged Mechanical Design With Coating on PCBs  
• Superior Thermal Design  
• High Reliability in Harsh Environments  
• Long Life Even at 71°C Operation  
• Reduces The Need For custom Outputs  
• Reduced System Filtering  
• Wide Range, Programmable Output Adjustment  
• Input Voltage Transient Protection  
Model Selector  
Nominal Output  
Adjustment  
Range  
(V)  
Maximum  
Current  
(A)  
Maximum  
Power  
(W)  
Part Number  
for Ordering  
Voltage  
(V)  
Model Number*  
LZSA-1000-2  
LZSA-500-3  
LZSA-1000-3  
LZSA-1500-3-001  
LZSA-1500-4  
LZS-A1000-2  
LZS-A500-3  
LZS-A1000-3  
LZS-A1500-3-001  
LZS-A1500-4  
12  
24  
24  
24  
48  
10 - 15.75  
18 - 29.4  
18 - 29.4  
18 - 29.4  
36 - 56  
84  
21  
42  
63  
31.5  
1008  
504  
1008  
1512 (3)  
1512 (3)  
* This part number is listed on the LZSA rating label and safety files  
1
LZSA Series  
Specification  
Model  
LZSA500  
LZSA1000  
LZSA1500  
Input  
Input Voltage Range (Operating)  
Nominal Input Voltage Range  
Input Frequency (2)  
DC Input Voltage range (1)  
Input Current Maximum (100Vac)  
Inrush Current (110 / 220Vac)  
Leakage Current  
Vac  
Vac  
Hz  
Vdc  
A
85 - 265  
100-240 (Note: Safety certified for 90-264Vac)  
47-440 (Note: Safety certified for 47-63Hz only)  
100-380V (Note: Safety certified for AC input only)  
15  
8
18  
A
25 / 45  
30 / 40  
uA  
-
<500 at 265Vac, 60Hz  
Power Factor  
EN61000-3-2 Class A  
Harmonics  
-
EN61000-3-2 Compliant  
20 hold up, 20 ride through  
84  
Hold Up Time at 110Vac Input  
Efficiency (Typical)  
ms  
-
Emissions  
-
EN55032/EN55011 Class B, EN61000-3-3, MIL STD 461/462D, CE102  
See Immunity Table  
Immunity  
-
Line Dip  
-
SEMI F47 Compliant (4)  
Safety Certifications and Markings  
-
IEC/EN/UL/CSA62368-1, 60950-1, UL508, CE Mark, UKCA Mark  
Immunity  
Test  
ESD  
Standard  
Test Level  
Criteria  
B
Notes  
IEC 61000-4-2  
IEC 61000-4-3  
IEC 61000-4-4  
IEC 61000-4-5  
IEC 61000-4-6  
±8kV air discharge,  
±6kV contact discharge  
10V/m, 80 - 1000MHz  
(80% AM at 1kHz)  
Radiated Susceptibility  
Electrical Fast Transient Burst  
Surge  
A
A
A
AC line pulses of ±2 kV;  
I/O line pulses of ±2kV>3m  
±2kV common mode,  
±1kV differential mode  
10Vrms, 150kHz - 80 MHz  
1kHz 80% AM  
See test report  
on website  
Conducted Susceptibility  
A
A
Magnetic fields  
IEC 61000-4-8  
30Arms/m @ 50Hz  
Voltage Dips and Input Interruptions  
IEC 61000-4-11  
Voltage Dips of 30%, 60% and  
100%; Interruptions of >95%  
6kV/30 ohms  
A & B  
A
Ring Wave  
IEEE C62.41  
SEMI F47  
SEMI F47 Line Dip  
See installation manual on website  
2
LZSA Series  
Specification  
Model  
LZSA500  
LZSA1000  
LZSA1500  
Output  
Line Regulation  
%
0.10  
0.10  
Load Regulation  
%
Transient Response  
Temperature Coefficient  
Ripple & Noise (pk-pk) (max.)  
Minimum Load  
-
±1% deviation, recovering to ±0.2% in <1.25ms (25% load change)  
ppm/°C  
100  
mV  
75  
75  
None  
24V: 75, 48V: 150  
A
%
-
Overcurrent Protection  
Overvoltage Protection  
Overtemperature Protection  
Remote Sense  
110-130  
User adjustable from front panel  
-
Internal thermostat. Cycle AC to reset.  
Compensates for a total of 1V cable drop  
TTL compatible, active high  
-
Remote On/Off  
-
Remote Adjust  
-
Using front panel potentiometer, Resistance (1k/V), or Voltage (1V/V)  
Opto coupled, conducts up to 1mA @ <0.4V when active  
Opto coupled, conducts up to 1mA @ <0.4V when active  
Opto coupled, conducts up to 1mA @ <0.4V when active  
Input Power Good  
DC Good  
-
-
Inverter good  
-
Synchronization (Sync)  
Indicators  
-
Auxiliary signal at approximately 200kHz used for synchronizing with other equipment.  
Green LED indicates output good; red LED indicates overvoltage, overtemperature, or overcurrent  
Single wire current share  
-
Parallel Operation  
Series Operation  
Environmental  
Operating Temperature  
-
-
See Installation Manual  
°C  
-40 to +71, derate linearly to 60% load from 60 - 71°  
(A 20 minute warm up period needed for <30°)  
-40 to +85  
Storage Temperature  
Humidity (non condensing)  
Cooling  
°C  
%RH  
10 - 90  
-
Variable speed, ball bearing fan  
Altitude  
m
3,000 operating, 12,000 non-operating  
Input to Ground 2,121, Input to Output 4,242, Output to Ground 500  
MIL-STD-810E, Method 514.4, Category 1, 9  
MIL-STD-810E, Method 516.4, Procedure I, II, IV, VI  
Withstand Voltage  
Vibration  
VDC  
-
-
Shock  
Other  
Weight (Typ)  
lbs / kg  
mm  
6.6 / 2.95  
108 x 121 x 260  
4.25 x 4.75 x 10.25  
132,958  
8.1 / 3.7  
Size (WxHxD) (excluding bus bars)  
Size (WxHxD) (excluding bus bars)  
MTBF - Bellcore  
Warranty  
143 x 121 x 267  
5.62 x 4.75 x 10.5  
Inches  
Hours  
Years  
99,039  
5
99,039  
Notes  
(1) Startup >110VDC  
(2) Reduced power factor above 63Hz  
(3) 1512W @ 180-265Vac, 1200W @ 120Vac, 1104W @ 100Vac, 1008W @ 85Vac  
(4) See website for detailed specifications, test methods and installation manual  
Derating Charts  
3
LZSA Series  
LZSA 500 Outline Drawing  
LZSA 1000 Outline Drawing  
4
LZSA Series  
LZSA 1500 Outline Drawing  
5
LZSA Series  
TDK-Lambda France SAS  
TDK-Lambda Americas  
Tel: +33 1 60 12 71 65  
Tel: +1 800-LAMBDA-4 or 1-800-526-2324  
tla.powersolutions@tdk.com  
www.us.lambda.tdk.com  
tlf.fr.powersolutions@tdk.com  
www.emea.lambda.tdk.com/fr  
Italy Sales Office  
Tel: +39 02 61 29 38 63  
tlf.it.powersolutions@tdk.com  
www.emea.lambda.tdk.com/it  
TDK Electronics do Brasil Ltda  
Tel: +55 11 3289-9599  
sales.br@tdk-electronics.tdk.com  
www.tdk-electronics.tdk.com/en  
Netherlands  
tlf.nl.powersolutions@tdk.com  
www.emea.lambda.tdk.com/nl  
TDK-Lambda Germany GmbH  
Tel: +49 7841 666 0  
tlg.powersolutions@tdk.com  
TDK-Lambda Corporation  
Tel: +81-3-6778-1113  
www.jp.lambda.tdk.com  
www.emea.lambda.tdk.com/de  
TDK-Lambda (China) Electronics Co. Ltd.  
Tel: +86 21 6485-0777  
tlc.powersolutions@tdk.com  
www.lambda.tdk.com.cn  
Austria Sales Office  
Tel: +43 2256 655 84  
tlg.at.powersolutions@tdk.com  
TDK-Lambda Singapore Pte Ltd.  
Tel: +65 6251 7211  
tls.marketing@tdk.com  
www.sg.lambda.tdk.com  
www.emea.lambda.tdk.com/at  
Switzerland Sales Office  
Tel: +41 44 850 53 53  
tlg.ch.powersolutions@tdk.com  
www.emea.lambda.tdk.com/ch  
TDK India Private Limited, Power Supply Division  
Tel: +91 80 4039-0660  
mathew.philip@tdk.com  
www.sg.lambda.tdk.com  
Nordic Sales Office  
Tel: +45 8853 8086  
tlg.dk.powersolutions@tdk.com  
www.emea.lambda.tdk.com/dk  
TDK-Lambda UK Ltd.  
Tel: +44 (0) 12 71 85 66 66  
tlu.powersolutions@tdk.com  
www.emea.lambda.tdk.com/uk  
TDK-Lambda Ltd.  
Tel: +9 723 902 4333  
tli.powersolutions@tdk.com  
www.emea.lambda.tdk.com/il-en  
For Additional Information, please visit  
https://product.tdk.com/en/power/  
LZSA 260822 June 28, 2023 V2  
6
LZSA Series  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY