NV1-1T000 [TDK]
AC-DC电源;型号: | NV1-1T000 |
厂家: | TDK ELECTRONICS |
描述: | AC-DC电源 输出元件 |
文件: | 总6页 (文件大小:1181K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NV-Power NV-175
https://emea.tdk-lambda.com/nv
https://product.tdk.com/en/power/nv
175/180/200W Configurable
ac/dc power supply.
Medical
Industrial
Test
Broadcast
Renewable
Comms
Features
Benefits
•ꢀHighꢀefficiency
Minimisesꢀheatꢀinꢀsystem
•ꢀLowꢀprofile
Fits 1U applications
•ꢀHighꢀpowerꢀdensity
Reduces space requirement
Reducesꢀsystemꢀnoise
Low cost of ownership
•ꢀTemperature controlled fan option
•ꢀ3ꢀyearꢀwarranty
Input
90-264Vac
133-388Vdc also available, contact sales
Input Voltage
45 - 63Hz
Input Frequency
(440Hz with reduced PFC - consult sales office)
Input Harmonics
Input Fuse
EN61000-3-2 compliant
Timelag (not user accessible)
123µA at 120Vac (60Hz), 257µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 500µA Single Fault Condition)
Inrush Current
<40A at 25°C and 230Vac (cold start)
Earth Leakage
Current
Available Outputs
Adjustment
Range
Adjustment
Range
Adjustment
Range
Adjustment
Range
Channel 1
Channel 21
Channel 33
Channel 44
1
2
3
0
1.8V / 15A
0.9 - 2.5V
2.5 - 3.3V
2.5 - 3.3V
T
F
-12V / 1A
-15V / 1A
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
2.7V / 15A
3.3V / 15A
Omit
5
5V / 25A2
5 - 5.5V
T
F
G
0
12V / 5A
12 - 15V
12 - 15V
18 - 24V
3H -3.3V / 2A9
5H -5V / 2A9
TH -12V / 2A9
FH -15V / 2A9
0H Fan supply only
15V / 5A
24V / 2.5A
Omit
T
F
12V / 15A
15V / 12A
12 - 15V5
12 - 15V6
5
0
5V / 10A10
Omit
3.3 - 5.5V
3.3 - 5.5V
5
0
5V / 8A8
Omit
G
24V / 7.5A
24 - 28V7
0
Omit
1. 1.8V,ꢀ2.7V,ꢀ3.3Vꢀchannelꢀ2ꢀonlyꢀavailableꢀwithꢀ5VꢀChannelꢀ1 3. Followꢀlettersꢀinꢀredꢀbyꢀ‘Y’ꢀforꢀnegativeꢀoutputꢀchannelꢀ3.
5V/10Aꢀchannelꢀ2ꢀonlyꢀavailableꢀwithꢀ12Vꢀorꢀ15VꢀChannelꢀ1 4. Followꢀlettersꢀinꢀredꢀbyꢀ‘P’ꢀforꢀpositiveꢀoutputꢀchannelꢀ4.
5V/8Aꢀchannelꢀ2ꢀonlyꢀavailableꢀwithꢀ24VꢀChannelꢀ1.
2. MaximumꢀcombinedꢀoutputꢀcurrentꢀfromꢀCh1ꢀ&ꢀCh2ꢀ=ꢀ25A
Models with 5V channel 1 are limited to 175W output power
7. 24ꢀ-ꢀ24.5Vꢀifꢀ5Vꢀchannelꢀ2ꢀfitted
24ꢀ-ꢀ26Vꢀifꢀ24Vꢀchannelꢀ3ꢀfitted.
8. 7Aꢀmaxꢀwithꢀ‘-F’ꢀorꢀ‘-I’ꢀoption.
9. 1.5Aꢀmaxꢀwithꢀ‘-F’ꢀorꢀ‘-I’option.
10. 9Aꢀmaxꢀwithꢀ‘-F’ꢀorꢀ‘-I’option.
5. 12ꢀ-ꢀ12.5Vꢀifꢀ24Vꢀchannelꢀ3ꢀfitted.
6. 14.5ꢀ-ꢀ15Vꢀifꢀ24Vꢀchannelꢀ3ꢀfitted
Other output options are available, please contact sales office with your requirements
Isolation
2 x MOOPs (3rd edition 60601)
4.3kVdc
Medical reinforced (2 x MOPPs) version available, contact sales office for
details.
Input to Output
1 x MOOP (3rd edition 60601)
1.5kVac, 2.3kVdc
Input to Earth
Output to Earth 200Vdc
NV175_Datasheet_69530 - v33.0
1
NV-Power NV-175
How To Create A Product Description
Confirm availability of created product with TDK-Lambda
Blank standard, vertical connector
Global
Option
Case
Option
Connector
Option
Right angled connector
#o/p
Ch1
Ch2
Ch32
Ch43
NV1-
-R (see handbook for ‘R’ connection
and mechanical details)
Blank no case
-C U chassis + cover
-U U chassis
Number of outputs
(excluding standby supply)
-F End fan + case
Letter / number from ‘Available
Ch1 - Ch4 Outputs’ table to represent
output voltage
-I End fan + case1+ IEC inlet1
Blank no option
-N 5V / 2A standby
-N1 12V / 1A standby
-N2 13.5V / 1A standby
-N3 5V / 2A standby, ATX compatible
-N4 12V / 1A standby, ATX compatible
1. Needs 0H, 3H, 5H, TH or FH type channel 4.
The fan speed is temperature dependent, ensuring optimum cooling and lowest audible noise.
2. For negative output channel 3, follow chosen letter by ‘Y’. For example, TY channel 3 = -12V / 5A.
3. For positive output channel 4, follow chosen letter by ‘P’. For example, TP channel 4 = +12V / 1A.
Output Specification
Turn on time
1.5s max
up to 90%
16ms min
<1%
at 90Vac and 100% rated output power
configuration dependent
at 90Vac
Efficiency
Hold up
Ripple and Noise
Voltage Accuracy
Remote Sense
Minimum Load
(or 50mV if higher) pk-pk, using EIAJ test method & 20MHz bandwidth
±4% for Channel 4 with ‘T’ or ‘F’ type outputs, +4/-3% for all other channel 4.
Channels 1 & 2. Max 0.5V total line drop
±1%
Yes
No
on any output
Including Line (for 90-264Vac input change), Load (for 0-100% load change) and
Cross (for 0-100% load change on any other output) regulation.
1%
Total Regulation
(or 50mV if greater)
of set voltage for 50% load change
(in 50µs within the range 25-100% load)
Transient Response
<4%
Recovery
500µs
Yes
for recovery to 1% of set voltage
See Application Notes for details
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection
Yes
Yes
Single output units with 12V, 15V or 24V (T, F or G). Average output power must not
exceed 180W over any 5 minute period
Peak Output Power
Ch1 Good Signal
200W
Yes
Provides a Logic ‘Low’ signal after Channel 1 output is within 90% (±5%) of nominal
QUICK SELECTOR - example configurations
Model
Ch1
Ch2
Ch3
Ch4
Ch5
Global Option
No
NV1-1T000
12V / 15A
24V / 7.5A
5V / 25A
5V / 25A
5V / 25A
5V / 25A
24V / 7.5A
24V / 7.5A
24V / 7.5A
24V / 7.5A
-
-
-
-
NV1-1G000
NV1-453TT
-
-
-
-
No
3.3V / 15A
3.3V / 15A
3.3V / 15A
3.3V / 15A
5V / 8A
5V / 8A
5V / 8A
5V / 8A
12V / 5A
12V / 5A
15V / 5A
15V / 5A
12V / 5A
12V / 5A
15V / 5A
15V / 5A
-12V / 1A
-12V / 1A
-15V / 1A
-15V / 1A
-12V / 1A
-12V / 1A
-15V / 1A
-15V / 1A
-
No
NV1-453TT-N3
NV1-453FF
5V / 2A
ATX (-N3)
No
-
NV1-453FF-N3
NV1-4G5TT
NV1-4G5TT-N3
NV1-4G5FF
NV1-4G5FF-N3
5V / 2A
-
ATX (-N3)
No
5V / 2A
-
ATX (-N3)
No
5V / 2A
ATX (-N3)
Additionalꢀvariantsꢀavailableꢀ‘BuiltꢀtoꢀOrder’ꢀ-ꢀseeꢀ‘Howꢀtoꢀcreateꢀaꢀproductꢀdescription’
NV175_Datasheet_69530 - v33.0
NV-Power NV-175
2
Global Signals (-N, -N1 and -N2 option models)
Global Signals (-N3 and -N4 option models)
TTL logic level high inhibits all outputs (except
Standby)
ATX Remote
on/off
TTL logic level high or open circuit inhibits all
outputs (except Standby)
Remote on/off
Open collector output (referenced to PSU 0V).
Turns on to indicate ac supply is good and output 1
is within regulation.
ATX Power
Good
Logic high indicates ac supply is good and output 1
is within regulation.
Power Good
Isolated supply, not affected by remote on/off
-N option = 5V / 2A (2.5A peak)
-N1 Option = 12V / 1A
Common 0V with power supply. Not affected by ATX
remote on/off
-N3 option = 5V / 2A
Standby Supply
Standby Supply
-N2 Option = 13.5V / 1A
-N4 Option = 12V / 1A
Immunity EN61000-6-2:2005, EN60601-1-2:2007
Criteria
Air discharge 15kV, Contact discharge 8kV. Not applicable to open
frame units
A
A
A
Electrostatic Discharge
Electromagnetic Field
Fast / Burst Transient
EN61000-4-2
EN61000-4-3
EN61000-4-4
Level 4
Level 3
Level 4
12V/m
ac input tested to 4.4kV
dc output tested to 2.2kV
Common mode - 2.2kV, Differential - 1.1kV
Surge Immunity
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3
Level 3
Level 4
A
A
A
A
12V
Conducted RF Immunity
Power Frequency Magnetic Field
30A/m
Criteria B for 5 sec interruption and dips to 40% for 5 cycles below
154Vac nominal input
Voltage Dips, Variations, Interruptions EN61000-4-11 Class 3
Emissions EN61000-6-3:2007, EN60601-1-2:2007
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
see application note for details. Additional filtering is required for IEC inlet version
Radiated Electric Field
EN55011, EN55032
Conducted Emissions
Conducted Harmonics
Flicker
EN55011, EN55032
EN61000-3-2
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Class A
EN61000-3-3
Compliant - dmax only
Environment
0°C to 50°C operational, -40°C to 70°C storage (max 12 months).
Full load, with either ‘-F’ option fitted or 2m/s air blown from input to output (approximately 10CFM)
Temperature
Derating
50°C to 70°C derate each output by 2.5% per °C
-20°C
Low Temp Startup
Humidity
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Shock
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Vibration
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9
Altitude
3000 metres operational
Pollution
Degree 2, Material group IIIb
Approvals / Accreditations
IEC/EN 62368-1, UL62368-1 / CSA 22.2 No 62368-1
File E135494
File E135494
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
File E349607
IEC/EN61010
File E331788
Low Voltage Directive (LVD), electromagnetic compatibility
(EMC) and Restriction of Hazardous Substances (RoHS)
CE Mark (EN62368-1)
CB certificate and Report available on request
Please check with technical sales for status of approvals
Designed and manufactured under the control of ISO9001 and ISO13485 (including risk management).
NV175_Datasheet_69530 - v33.0
3
NV-Power NV-175
Outline & Connection Drawings
Top View
NV175 models
without cover
128.20
Top View
NV175-N & NV175-Nx
models without cover
Input and output connectors are not included
with the product. They are available from
TDK-Lambda
Part
Contents
Number
94910
94911
1 off input connector and 3 crimps
1 off output connector and 24 crimps
128.20
Side View
NV175 models without cover
or chassis
End View
Notes: 1. All customer fixings M3
2. Maximum thread penetration 4.5mm
3. Maximum torque 0.9Nm
4. All tolerances +/-0.5mm
NV175_Datasheet_69530 - v33.0
NV-Power NV-175
4
Outline & Connection Drawings
Top View
Top View
NV175-N-C & NV175-Nx-C
models
NV175-C models
Side View
Side View
NV175-C & NV175-U models
NV175-N-C, NV175-Nx-C, NV175-N-U
& NV175-Nx-U models
Bottom View
NV175-N-C, NV175-Nx-C, NV175-N-U &
NV175-Nx-U models
Bottom View
NV175-C & NV175-U models
NV-175 units with fan (-F or -I)
Top View
Top View
Side View
Side View
Bottom View
Bottom View
Otherꢀdimensionsꢀsameꢀasꢀcasesꢀwithoutꢀfansꢀ(above)
Notes: 1. All customer fixings M3
2. Maximum thread penetration 4.5mm
3. Maximum torque 0.9Nm
4. All tolerances +/-0.5mm
NV175_Datasheet_69530 - v33.0
5
NV-Power NV-175
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
powersolutions@us.tdk-lambda.com
www.us.lambda.tdk.com
Tel: +33 1 60 12 71 65
france@fr.tdk-lambda.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
info.italia@it.tdk-lambda.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
info@nl.tdk-lambda.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
info.germany@de.tdk-lambda.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
powersolutions@cn.tdk-lambda.com
www.lambda.tdk.com.cn
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.mkt@sg.tdk-lambda.com
www.sg.lambda.tdk.com
Austria Sales Office
Tel: +43 2256 655 84
info@at.tdk-lambda.com
www.emea.lambda.tdk.com/at
TDK India Private Limited, Power Supply Division
Switzerland Sales Office
Tel: +41 44 850 53 53
info@ch.tdk-lambda.com
www.emea.lambda.tdk.com/ch
Tel: +91 80 4039-0660
mathew.philip@in.tdk-lambda.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
info@dk.tdk-lambda.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
powersolutions@uk.tdk-lambda.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
info@tdk-lambda.co.il
www.emea.lambda.tdk.com/il
C.I.S.
Commercial Support:
Tel: +7 (495) 665 2627
Technical Support:
Tel: +7 (812) 658 0463
info@tdk-lambda.ru
www.emea.lambda.tdk.com/ru
For additional information, please visit
https://product.tdk.com/en/power
Errors and omissions excepted
NV175_Datasheet_69530 - v33.0
NV-Power NV-175
6
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明