Vega450 [TDK]
AC-DC电源;Vega Series
https://emea.lambda.tdk.com/vega
https://product.tdk.com/en/power/vega
450W - 900W
Modular power supply.
Medical
Industrial
Test
Broadcast
Renewable
Comms
Features
Benefits
•ꢀIndustryꢀleadingꢀflexibility
Suits your application
•ꢀScrew, Fast-on or IEC connection
•ꢀWorldwide safety approvals
•ꢀUp to 11 outputs
Simplifiesꢀdesignꢀintoꢀsystem
Supports global use
Eliminates need for additional supplies
Low cost of ownership
•ꢀ3 year warranty
Input
Vega 450, 650 and 900
Vega dc (450W)
Input Voltage /
Frequency
90-264Vac / 47 - 63 Hz (440Hz with reduced PFC)
900W version is 150-264Vac only, 650W below 150Vac
34 - 75Vdc
derate linearly below 44V to 340W at 34V
Input Fuse
16A / 250Vac HBC Fast acting (not user accessible)
<40A at 25°C and 264Vac (cold start)
20A Fast acting (not user accessible)
<40A at 25°C, ETSI EN300 132-2
n/a
Inrush Current
Leakage Current See ‘How To Create A Product Description’ for details
How To Create A Product Description
The extensive range of output modules and options make it possible to achieve almost any combination of Volts and Amps. You can create
your own Vega configuration online at https://config.emea.tdk-lambda.com/. This method checks your configuration and offers the optimum
solution. Alternatively, you can do this manually by using the guide below.
1.
Calculate total output power to select the appropriate converter, then select required Cooling, Connection, Leakage Current and Controls/
Signals from the following table:
V4
F
S
S
F
V0 450W (dc in)
V4 450W
F
ac fail, psu+fan inhibit, 5V/100mA standby
FV ac fail, psu+fan inhibit, 5V/300mA standby
Primary xFWcd ac fail, psu+fan inhibit, 5-15V/1A standby
Converter
Cooling
V6 650W
V9 900W
Option
E
ac fail, psu+fan enable, 5V/100mA standby
F
Forward air - standard
EV ac fail, psu+fan enable, 5V/300mA standby
xEWcd ac fail, psu+fan enable, 5-15V/1A standby
Qd Forward air - Quiet
Ra Reverse air
Pad Reverse air - Quiet fan
Cb Customer air - no fan
S
M
L
R
T
Standard 1.5mA
650µA
290µA
175µA
60µA
Leakage
Current
(max leakage
current at 264Vac,
63Hz)
S
Screw
Input
Connection
Fd Fast-on terminal
Id IEC320 with switch
a) Not available for Vega 900
b) Thermocoupled sample recommended to ensure adequate
cooling - consult sales
c)ꢀxFXꢀandꢀxEWꢀoptionsꢀincreaseꢀleakageꢀcurrentꢀbyꢀ90µA.ꢀRe-
placeꢀ‘x’ꢀwithꢀrequiredꢀoutputꢀvoltageꢀ(5FWꢀ=ꢀ5Vꢀstandbyꢀsupply)
d) Not available for Vega dc
2.
Select Output Modules and options from the output voltages tables.
Example - if you require 5.2V / 18A with output inhibit :-
a) Select B1H as closest match for voltage & current and prefix with voltage (eg 5.2B1H)
b) add suffix ‘S’ or ‘F’ for Screw or Fast-on output connection (eg 5.2B1HS)
c) add suffix ‘N’ for output inhibit if required (eg 5.2B1HSN)
d) Repeat for other outputs.
Ensure you do not select more than a total of 5 slots width of modules. This will create a complete product description eg V6FSSF 5L1SN
12/12H3/3S 24C5S which represents a four output 650W Vega with Forward air, Screw terminal input, 1.5mA leakage, ac Fail, Global
inhibit & 5V/100mA standby supply with the following outputs:
Output 1 = 5V/35A (with output inhibit, module good and current share option). Output 2 = 12V / 10A, Output 3 = 12V / 6A, Output 4 = 24V
/ 10A, all with screw terminal outputs.
3.
Contact TDK-Lambda to validate configuration and issue a part number.
Vega_Datasheet_69537 - v21.0
1
Vega Series
OUTPUT VOLTAGES (single output modules)
OUTPUT VOLTAGES (twin output modules)
Adjustment Range Current
V1 Adjustment Range
V2 Adjustment Range Current
Module
Slots
Module
Current
Slots
(Volts)
(Amps)
(Volts)
(Volts)
(Amps)
B1L
C1
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
3.9
4.2
3.8
3.9
3.8
4.2
3.8
3.9
3.9
5
-
3.8e
4.1e
4.1e
3.8
20
1
1
H1L/1L
H1L/1H
H1L/2
H1L/3
H1L/4
H1H/1L
H1H/1H
H1H/2
H1H/3
H1H/4
H2/1L
H2/1H
H2/2
1.8
3.9
5.6
9.1
16.3
1.8
3.9
5.6
9.1
16.3
1.8
3.9
5.6
9.1
16.3
1.8
3.9
5.6
9.1
16.3
1.8
3.9
5.6
9.1
16.3
-
3.8n
5.5d
9f
8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
35
40
50
60
80
95
114
20
35
45
50
60
66
75
95
104
25
12
18
24
40
45
45
18
30
36
14
18
27
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8
6
C1Y
D1L
E1
1
1.8
3.9
-
-
-
-
-
3.8n
12
1.5
2
16.2u
25p
6
3.8e
3.8
4.5
8
F1a
2
3.8n
5.5d
9f
Z2
3.8e
3.8e
5.5d
5.5d
9k
3
8
Z3
4
5.5d
12
10
10
5
6
B1H
L1
1
16.2u
25p
6
1
4.5
8
D2
1.5
1.5
2
3.8n
5.5d
9f
D1H
E2
5.5d
8k
8
5.6
9f
6
Z18
F2a
5.5
2
H2/3
16.2u
25p
6
8
2
H2/4
4.5
8
Z4
5.5d
5.5d
9f
3
H3/1L
H3/1H
H3/2
3.8n
5.5d
9f
Z6
3.5
1
8
B2
9.1
16.2u
6
B3
9.1
9.1
8
16.2g
16.2g
16.5g
13.9l
16.5g
16g
21.5i
19.9m
15
1
H3/3
16.2u
25p
6
C3
1
H3/4
4.5
8
D3
1.5
2
H5/1L
H5/1H
H5/2
3.8n
5.5d
9f
E3L
Z7
8
8
8
3
16.2
28
6
EE2
D4
7.6
14
4
H5/3
16.2u
25p
6
1.5
2
H5/4
4.5
E4
14
Wide Range Programmable Modules
Voltage Range Current Slots
E3H
C4
14
2
Module
W2a
16.3
18.2
20
21.5i
32.4j
24
1
0.25w
0.25x
-
-
7.5
32
30
1
1
Select features from table below
CC3
E5Lv
B5
2
W5
8.5
2
21.6
21.6
21
31h
31j
1
Follow by F or T
F or S
Fixed or Tracking Overvoltage protection
Fast-on or Screw output terminals
C5
10
15
25
36
5
1
D5
28
1.5
2
R or V
Resistance (0-32kΩ) or Voltage (0-5V) programming
1 Inhibit, Fixed Current Limit
E5Hv
Z19co
HH5/3
DD4
EE4c
HH5/4
BB4
EE5Lco
C5B4
EE5Ho
CC5
DD5
24
28
24
28
3.5
1
2 Inhibit, Programmable Current Limit (0-5V)
3 Enable, Fixed Current Limit
1, 2, 3
or 4
25.3
28
44.2b
43s
38
18
22.5
4.5
10
18
10
18
10
15
3
4 Enable, Programmable Current Limit (0-5V)
28
4
32.5
32.6
40
53t
1
Follow non wide range modules by F (Fast-on) or S (Screw) output terminals
43q
48
2
4
Options - Single output Modules*
Options - Twin output Modules*
43
48
2
N
R
Output Inhibit, Module Good &
Remote Sense
Output Inhibit, Module Good &
Current Sharing
48
56
4
N
48.1
42
62r
2
Remote Sense only
56
3
* see configuring guide
a) F1, F2 and W2 modules not for Vega 900
b)ꢀ38Vꢀmaxꢀforꢀ900W
c) Only available for Vega 900
d)ꢀ5.1Vꢀmaxꢀforꢀ900W
e)ꢀ3.4Vꢀmaxꢀforꢀ900W
f)ꢀ8Vꢀmaxꢀforꢀ900W
h)ꢀ28Vꢀmaxꢀforꢀ900W
i)ꢀ18Vꢀmaxꢀforꢀ900W
j)ꢀ30Vꢀmaxꢀforꢀ900W
k)ꢀ7.5Vꢀmaxꢀforꢀ900W
l)ꢀ12.5Vꢀmaxꢀforꢀ900W
m)ꢀ19Vꢀmaxꢀforꢀ900W
n)ꢀ3.4Vꢀmaxꢀforꢀ900W
o)ꢀ‘N’ꢀoptionꢀnotꢀavailable
v)ꢀ‘N’ꢀoptionꢀnotꢀavailableꢀifꢀmore
thanꢀ1ꢀmoduleꢀfitted
w)ꢀ500mAꢀminꢀloadꢀbelowꢀ1V
x)ꢀ100mAꢀminimumꢀloadꢀbelowꢀ2V
p)ꢀ24Vꢀmaxꢀforꢀ900W
q)ꢀ40Vꢀmaxꢀforꢀ900W
r)ꢀ60Vꢀmaxꢀforꢀ900W
s)ꢀ36Vꢀmaxꢀforꢀ900W
t)ꢀ52Vꢀmaxꢀforꢀ900W
u)ꢀ15.5Vꢀmaxꢀforꢀ900W
g)ꢀ15Vꢀmaxꢀforꢀ900W
Vega_Datasheet_69537 - v21.0
Vega Series
2
Isolation
2 x MOPPs (3rd edition 60601) - units without xFW or xEW primary option fitted
4kVac, 5.7kVdc type tested to 4kVac (equivalent to 5.7kVdc), production tested to 4.3kVdc.
Input to Output
Reinforced
Basic
Input to Earth
1 x MOOP (3rd edition 60601) 2.3kVdc
200Vdc
Output to Output / Output to Earth
Output Specification
Voltage / Current
Turn on time
See output voltages table
1.5s max
<50ms
at 90Vac (150Vac for 900W, 48Vdc for Vega dc) and 100% rated output power
Rise time
to 90% of voltage, monotonic rise above 10%
Turn on overshoot
Efficiency
<5% or 250mV
up to 75%
16ms min
<1% or 50mV
<1%
Load type dependent, no overshoot with resistive load
at 230Vac (48Vdc for Vega dc) & 100% rated power, configuration dependent
at 90Vac (150Vac for 900W) and 100% rated power (10ms min for Vega dc)
pk-pk, using EIAJ test method & 20MHz bandwidth
of set voltage
Hold up
Ripple and Noise
Voltage Accuracy
standard on single output modules, max 0.75V total line drop.
Option for twin output modules
Remote Sense
Yes
Minimum Load
No
<0.02%
on any output (except W2 and W5 modules which need 0.5A load to achieve full specification)
of rated voltage per °C
Temperature Coefficient
Load Regulation
Line Regulation
<0.5% or 50mV
<0.1%
for 0-100% load change
for 90-264Vac input change (34 - 75Vdc for Vega dc)
for 100% load change on any output
Cross Regulation
Transient Response
Recovery
<0.2%
<6% or 300mV
500µs
of set voltage for 50% load change (above 25% load)
for recovery to 1% or 100mV of set voltage
Refer to application notes for details
Over Voltage Protection
Yes
105-125%
110-170%
of rated current, constant current characteristic
For EE2, EE4, EE5L, EE5H, Z2, Z18 and Z19 modules
Over Current Protection (singles)
Short Circuit Protection
<150%
Yes
of rated current, when output voltage <1%
shuts down all outputs and fan. Cycle ac off/on to reset
Over Temperature Protection
Shutdown temperature varies according to ambient, output power and input voltage.
ac fail signal (if fitted) provides 5ms warning of thermal shutdown
Environment
Temperature
0°C to 65°C operational, -40°C to 70°C storage (max 12 months).
Derating
50°C to 65°C derate total output power and each output current by 2.5% per °C
Low Temp Startup
Humidity
-20°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Shock
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Vibration
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1, 9
Altitude
Pollution
IP Rating
5000 metres operational/non operational (IEC inlet 3000m operational, 5000m non operational)
Degree 2, Material group IIIb
IP 10
Vega_Datasheet_69537 - v21.0
3
Vega Series
Emissions EN61000-6-3:2007, EN60601-1-2:2001
(as per CISPR.11/22) Class B (Class A for Vega dc), FCC47 part 15 subpart B
Radiated Electric Field
EN55011, EN55032
see application note for details. Additional filtering required for IEC inlet version.
Only for ‘S’ type leakage variants.
(as per CISPR.11/22) Class B (Class A for Vega dc), FCC47 part 15 subpart B
Only for ‘S’ type leakage variants. ‘M’ and ‘L’ types meet Class A
Conducted Emissions
EN55011, EN55032
Conducted Harmonics
Flicker
EN61000-3-2
EN61000-3-3
Class A - not applicable to Vega dc
Compliant - dmax only - not applicable to Vega dc
Immunity EN61000-6-2:2005, EN60601-1-2:2001
Criteria
Air discharge 15kV, Contact discharge 8kV
12V/m
A
Electrostatic Discharge
EN61000-4-2
Level 4
Level 3
Electromagnetic Field
EN61000-4-3
A
ac input tested to 4.4kV (2kV for Vega dc)
dc output tested to 2.2kV (1kV for Vega dc)
Tested at 5kHz and 100kHz
Level 4
Level 3 for Vega dc
Fast / Burst Transient
Surge Immunity
EN61000-4-4
EN61000-4-5
A
A
Level 3
Level 2 for Vega dc
Common mode - 2.2kV (1.1kV for Vega dc)
Differential - 1.1kV (0.55kV for Vega dc)
12V
Conducted RF Immunity
EN61000-4-6
EN61000-4-8
Level 3
Level 4
A
A
30A/m
Power Frequency Magnetic Field
Voltage Dips, Variations, Interruptions EN61000-4-11
Class 3
A
na - Vega dc
B for 5s interruptions
Approvals / Accreditations
IEC/EN 62368-1, UL62368-1 / CSA 22.2 No 62368-1
File E135494
File E135494
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
File E349607 (not Vega dc, only for L, R and T leakage variants)
IEC/EN 61010-1
File E331788
Low Voltage Directive (LVD), electromagnetic compatibility
(EMC) and Restriction of Hazardous Substances (RoHS)
CE Mark (EN62368-1)
CB certificate and Report available on request
Please check with technical sales for status of approvals
Designed and manufactured under the control of ISO9001 and ISO13485 (including risk management).
Vega_Datasheet_69537 - v21.0
Vega Series
4
Vega_Datasheet_69537 - v21.0
5
Vega Series
TDK-Lambda France SAS
TDK-Lambda Americas
Tel: +1 800-LAMBDA-4 or 1-800-526-2324
powersolutions@us.tdk-lambda.com
www.us.lambda.tdk.com
Tel: +33 1 60 12 71 65
france@fr.tdk-lambda.com
www.emea.lambda.tdk.com/fr
Italy Sales Office
Tel: +39 02 61 29 38 63
info.italia@it.tdk-lambda.com
www.emea.lambda.tdk.com/it
TDK Electronics do Brasil Ltda
Tel: +55 11 3289-9599
sales.br@tdk-electronics.tdk.com
www.tdk-electronics.tdk.com/en
Netherlands
info@nl.tdk-lambda.com
www.emea.lambda.tdk.com/nl
TDK-Lambda Germany GmbH
Tel: +49 7841 666 0
info.germany@de.tdk-lambda.com
TDK-Lambda Corporation
Tel: +81-3-6778-1113
www.jp.lambda.tdk.com
www.emea.lambda.tdk.com/de
TDK-Lambda (China) Electronics Co. Ltd.
Tel: +86 21 6485-0777
powersolutions@cn.tdk-lambda.com
www.lambda.tdk.com.cn
TDK-Lambda Singapore Pte Ltd.
Tel: +65 6251 7211
tls.mkt@sg.tdk-lambda.com
www.sg.lambda.tdk.com
Austria Sales Office
Tel: +43 2256 655 84
info@at.tdk-lambda.com
www.emea.lambda.tdk.com/at
TDK India Private Limited, Power Supply Division
Switzerland Sales Office
Tel: +41 44 850 53 53
info@ch.tdk-lambda.com
www.emea.lambda.tdk.com/ch
Tel: +91 80 4039-0660
mathew.philip@in.tdk-lambda.com
www.sg.lambda.tdk.com
Nordic Sales Office
Tel: +45 8853 8086
info@dk.tdk-lambda.com
www.emea.lambda.tdk.com/dk
TDK-Lambda UK Ltd.
Tel: +44 (0) 12 71 85 66 66
powersolutions@uk.tdk-lambda.com
www.emea.lambda.tdk.com/uk
TDK-Lambda Ltd.
Tel: +9 723 902 4333
info@tdk-lambda.co.il
www.emea.lambda.tdk.com/il
C.I.S.
Commercial Support:
Tel: +7 (495) 665 2627
Technical Support:
Tel: +7 (812) 658 0463
info@tdk-lambda.ru
www.emea.lambda.tdk.com/ru
For additional information, please visit
https://product.tdk.com/en/power
Errorsꢀandꢀomissionsꢀexcepted
Vega_Datasheet_69537 - v21.0
Vega Series
6
相关型号:
©2020 ICPDF网 联系我们和版权申明