CCR-38SX40-TM [TELEDYNE]

Normally Open Coaxial Switch;
CCR-38SX40-TM
型号: CCR-38SX40-TM
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

Normally Open Coaxial Switch

文件: 总13页 (文件大小:817K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
PART NUMBER DESCRIPTION  
CCR-38S  
CR-38S  
Commercial Normally Open Multi-throw, DC-18GHz  
Elite Normally Open Multi-throw, DC-22GHz  
The CCR-38S/CR-38S is a broadband, multi-throw, electromechanical coaxial switch designed to switch  
a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. The characteristic impedance  
is 50 Ohms. The switches are small using the popular connector spacing on a 1.062” dia. circle. Each  
position has an individual actuator mechanism allowing random position selection. This also gives the  
minimum switching time.  
With the normally open actuator, all paths are open when the switch is de-energized.  
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS  
ELECTRICAL CHARACTERISTICS  
Operating Temperature  
Form Factor  
Multi-Throw,  
Commercial Model, CCR-38S  
Elite Model, CR-38S  
–40°C to 65°C  
–55°C to 85°C  
break before make  
Frequency Range  
CCR-38S  
CR-38S  
Vibration (MIL-STD-202 Method 214,  
Condition D, non-operating)  
10 g’s RMS  
DC–18 GHz  
DC-22 GHz  
Shock (MIL-STD-202 Method 213,  
Condition D, non-operating)  
500 g’s  
Characteristic Impedance  
Operate Time  
50 Ohms  
15 ms (max.)  
15 ms (max.)  
12 15 24 28  
Standard Actuator Life  
Actuator Life w/ Additional Features  
5,000,000 cycles  
1,000,000 cycles  
Release Time  
Actuation Voltage Available  
Actuation Current, max. @ ambient  
V
Connector Type  
Humidity (Moisture Seal)  
Weight  
SMA  
400 205 170 140 mA  
Available  
6 oz. (170.1g) (max.)  
PERFORMANCE CHARACTERISTICS  
Frequency  
DC–4 GHz  
4–8 GHz  
8–12 GHz  
12–16 GHz  
16-20 GHz  
20-22 GHz  
Insertion Loss, dB,  
max.  
0.1  
0.2  
0.2  
0.3  
0.3  
0.4  
Isolation, dB, min.  
VSWR , max.  
80  
80  
80  
80  
75  
70  
1.05:1  
1.1:1  
1.2:1  
1.2:1  
1.2:1  
1.2:1  
PART NUMBERING SYSTEM  
CCR-38  
S
1
6
C
-
T **  
Series  
Options  
Connectors  
Actuator Voltage  
Actuator Type  
Number of Positions  
CONNECTOR  
ACTUATOR VOLTAGE  
NUMBER OF POSITIONS  
3: SP3T  
ACTUATOR TYPE  
OPTIONS  
S: SMA FEMALE  
1: 28 VDC NORMALLY OPEN  
2: 15 VDC NORMALLY OPEN  
3: 12 VDC NORMALLY OPEN  
4: 24 VDC NORMALLY OPEN  
0: NO INDICATOR CONTACTS  
C: INDICATOR CONTACTS  
T: TTL DRIVERS WITH DIODES  
D: COIL TRANSIENT SUPPRESSION DIODES  
S: D-SUB CONNECTOR*  
4: SP4T  
5: SP5T  
6: SP6T  
TD: DECODERS AND TTL DRIVERS WITH  
DIODES  
**SEE PARTS LIST ON PAGE 12-13  
M: MOISTURE SEAL  
* D-Sub Connector may be 9 or 15 pin depending on  
number of throws. (See Connector Pinout page)  
For additional options, please contact factory.  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 1  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
SCHEMATICS AND MECHANICAL OUTLINE  
Analog  
Indicators  
TTL  
SP3T  
SP4T  
SP5T  
H = 1.75 STD & Indicator Model  
H = 2.00 D-Sub Model  
SP6T  
H = 2.25 Indicator with D-Sub Model  
H = 2.50 TTL, TTL with Indicators & TTL with D-Sub Model  
“-S OPTION9-PIN D-SUB OR 15-PIN D-MICRO CONNECTOR (EXAMPLE: CCR-38S160-S)  
CCR-38S/CR-38S Page 2  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
CONNECTOR PINOUT FOR NORMALLY OPEN SP3T MULTI-THROW SWITCHES  
EXAMPLE  
CR-38S130-S  
CR-38S13C-S  
CR-38S130-TS  
CR-38S13C-TS  
CR-38S130-TDS  
CR-38S13C-TDS  
INDICATOR  
YES  
YES  
YES  
YES  
TTL  
YES  
DECODERS & TTL  
YES  
YES  
PIN NO.  
9-PIN  
9-PIN  
PORT 1  
9-PIN  
9-PIN  
PORT 1  
9-PIN  
9-PIN  
1
2
3
4
5
6
7
8
9
PORT 1  
PORT 2  
PORT 3  
PORT 1  
PORT 2  
PORT 3  
LOGIC 1  
LOGIC 2  
LOGIC 1  
LOGIC 2  
PORT 2  
PORT 2  
PORT 3  
PORT 3  
E INDICATOR  
F INDICATOR  
G INDICATOR  
COMMON  
E INDICATOR  
F INDICATOR  
G INDICATOR  
COMMON  
E INDICATOR  
F INDICATOR  
G INDICATOR  
COMMON  
COMMON  
COMMON  
VSW  
COMMON  
VSW  
VSW  
VSW  
D INDICATOR (COM)  
D INDICATOR (COM)  
D INDICATOR (COM)  
CONNECTOR PINOUT FOR NORMALLY OPEN SP4T MULTI-THROW SWITCHES  
EXAMPLE  
CR-38S140-S  
CR-38S14C-S  
CR-38S140-TS  
CR-38S14C-TS  
CR-38S140-TDS  
CR-38S14C-TDS  
INDICATOR  
YES  
YES  
YES  
YES  
TTL  
YES  
DECODERS & TTL  
YES  
YES  
PIN NO.  
9-PIN  
15-PIN  
PORT 1  
PORT 2  
PORT 3  
PORT 4  
9-PIN  
TTL 1  
TTL 2  
TTL 3  
TTL 4  
15-PIN  
TTL 1  
TTL 2  
TTL 3  
TTL 4  
9-PIN  
15-PIN  
LOGIC 1  
LOGIC 2  
LOGIC 3  
1
2
PORT 1  
PORT 2  
PORT 3  
PORT 4  
LOGIC 1  
LOGIC 2  
LOGIC 3  
3
4
5
6
7
COMMON  
COMMON  
COMMON  
VSW  
COMMON  
VSW  
COMMON  
VSW  
COMMON  
VSW  
8
9
D INDICATOR (COM)  
E INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
10  
11  
12  
13  
14  
15  
F INDICATOR  
G INDICATOR  
N/A  
N/A  
N/A  
H INDICATOR  
1
6
9-PIN D-SUB CONNECTOR  
15-PIN D-MICRO CONNECTOR  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 3  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
CONNECTOR PINOUT FOR NORMALLY OPEN SP5T MULTI-THROW SWITCHES  
EXAMPLE  
CR-38S150-S  
CR-38S15C-S  
CR-38S150-TS  
CR-38S15C-TS  
CR-38S150-TDS  
CR-38S15C-TDS  
INDICATOR  
YES  
YES  
YES  
YES  
TTL  
YES  
DECODERS & TTL  
YES  
YES  
PIN NO.  
9-PIN  
15-PIN  
PORT 1  
PORT 2  
PORT 3  
PORT 4  
PORT 5  
9-PIN  
TTL 1  
TTL 2  
TTL 3  
TTL 4  
TTL 5  
15-PIN  
TTL 1  
TTL 2  
TTL 3  
TTL 4  
TTL 5  
9-PIN  
15-PIN  
LOGIC 1  
LOGIC 2  
LOGIC 3  
1
2
PORT 1  
PORT 2  
PORT 3  
PORT 4  
PORT 5  
LOGIC 1  
LOGIC 2  
LOGIC 3  
3
4
5
6
7
COMMON  
COMMON  
COMMON  
VSW  
COMMON  
VSW  
COMMON  
VSW  
COMMON  
VSW  
8
9
D INDICATOR (COM)  
E INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
K INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
K INDICATOR  
10  
11  
12  
13  
14  
15  
F INDICATOR  
G INDICATOR  
H INDICATOR  
N/A  
N/A  
N/A  
K INDICATOR  
CONNECTOR PINOUT FOR NORMALLY OPEN SP6T MULTI-THROW SWITCHES  
EXAMPLE  
CR-38S160-S  
CR-38S16C-S  
CR-38S160-TS  
CR-38S16C-TS  
CR-38S160-TDS  
CR-38S16C-TDS  
INDICATOR  
YES  
YES  
YES  
YES  
TTL  
YES  
DECODERS & TTL  
YES  
YES  
PIN NO.  
9-PIN  
PORT 1  
PORT 2  
PORT 3  
PORT 4  
PORT 5  
PORT 6  
COMMON  
15-PIN  
PORT 1  
PORT 2  
PORT 3  
PORT 4  
PORT 5  
PORT 6  
COMMON  
9-PIN  
TTL 1  
TTL 2  
TTL 3  
TTL 4  
TTL 5  
TTL 6  
COMMON  
VSW  
15-PIN  
TTL 1  
9-PIN  
15-PIN  
LOGIC 1  
LOGIC 2  
LOGIC 3  
1
2
LOGIC 1  
LOGIC 2  
LOGIC 3  
TTL 2  
3
TTL 3  
4
TTL 4  
5
TTL 5  
6
TTL 6  
7
COMMON  
COMMON  
VSW  
COMMON  
VSW  
8
VSW  
9
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
K INDICATOR  
L INDICATOR  
D INDICATOR (COM)  
E INDICATOR  
F INDICATOR  
G INDICATOR  
H INDICATOR  
K INDICATOR  
L INDICATOR  
10  
11  
12  
13  
14  
15  
G INDICATOR  
H INDICATOR  
K INDICATOR  
L INDICATOR  
N/A  
N/A  
N/A  
CCR-38S/CR-38S Page 4  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TRUTH TABLE Normally Open  
CCR-38SX3C-T  
Logic  
Input  
RF Path  
J2  
Indicator  
Switches  
1
1
0
0
2
0
1
0
3
0
0
1
J1  
J3  
E
C
0
F
0
G
0
On Off Off  
Off On Off  
Off Off On  
C
0
0
0
C
TRUTH TABLE Normally Open  
CCR-38SX3C-TD  
Logic  
Input  
RF Path  
Indicator  
Switches  
1
2
0
0
1
1
J1  
J2  
J3  
E
C
0
F
0
C
0
0
G
0
0
1
0
1
On Off Off  
Off On Off  
Off Off On  
Off Off Off  
0
0
C
0
0
TRUTH TABLE Normally Open  
CCR-38SX4C-T  
Logic Input  
RF Path  
Indicator  
Switches  
1
1
0
0
0
2
0
1
0
0
3
0
0
1
0
4
0
0
0
1
J1 J2 J3 J4  
On Off Off Off  
Off On Off Off  
Off Off On Off  
Off Off Off On  
E
F
0
G
0
H
0
C
0
0
0
C
0
0
0
C
0
0
0
C
TRUTH TABLE Normally Open  
CCR-38SX4C-TD  
Logic Input  
RF Path  
Indicator  
Switches  
1
0
1
0
1
1
2
0
0
1
1
1
3
0
0
0
0
1
J1 J2 J3 J4  
On Off Off Off  
Off On Off Off  
Off Off On Off  
Off Off Off On  
Off Off Off Off  
E
C
0
0
0
0
F
0
C
0
0
0
G
0
H
0
0
0
C
0
0
C
0
0
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 5  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TRUTH TABLE Normally Open  
CCR-38SX5C-T  
Logic Input  
RF Path  
Indicator Switches  
1
1
0
0
0
0
2
0
1
0
0
0
3
0
0
1
0
0
4
0
0
0
1
0
5
0
0
0
0
1
J1 J2 J3 J4 J5  
On Off Off Off Off  
Off On Off Off Off  
Off Off On Off Off  
Off Off Off On Off  
Off Off Off Off On  
E
C
0
0
0
0
F
0
C
0
0
0
G
0
H
0
K
0
0
0
0
C
0
0
C
0
0
C
0
0
TRUTH TABLE Normally Open  
CCR-38SX5C-TD  
Logic Input  
RF Path  
Indicator Switches  
1
0
1
0
1
0
1
2
0
0
1
1
0
1
3
0
0
0
0
1
1
J1 J2 J3 J4 J5  
On Off Off Off Off  
Off On Off Off Off  
Off Off On Off Off  
Off Off Off On Off  
Off Off Off Off On  
Off Off Off Off Off  
E
C
0
0
0
0
0
F
0
C
0
0
0
0
G
0
0
C
0
0
0
H
0
0
0
C
0
0
K
0
0
0
0
C
0
TRUTH TABLE Normally Open  
CCR-38SX6C-T  
Logic Input  
RF Path  
Indicator Switches  
1
1
0
0
0
0
0
2
0
1
0
0
0
0
3
0
0
1
0
0
0
4
0
0
0
1
0
0
5
0
0
0
0
1
0
6
0
0
0
0
0
1
J1 J2 J3 J4 J5 J6  
On Off Off Off Off Off  
Off On Off Off Off Off  
Off Off On Off Off Off  
Off Off Off On Off Off  
Off Off Off Off On Off  
Off Off Off Off Off On  
E
C
0
0
0
0
0
F
0
C
0
0
0
0
G
0
0
C
0
0
0
H
0
0
0
C
0
0
K
0
0
0
0
C
0
L
0
0
0
0
0
C
TRUTH TABLE Normally Open  
CCR-38SX6C-TD  
Logic Input  
RF Path  
Indicator Switches  
1
0
1
0
1
0
1
1
2
0
0
1
1
0
0
1
3
0
0
0
0
1
1
1
J1 J2 J3 J4 J5 J6  
On Off Off Off Off Off  
Off On Off Off Off Off  
Off Off On Off Off Off  
Off Off Off On Off Off  
Off Off Off Off On Off  
Off Off Off Off Off On  
Off Off Off Off Off Off  
E
C
0
0
0
0
0
0
F
0
C
0
0
0
0
0
G
0
0
C
0
0
0
0
H
0
0
0
C
0
0
0
K
0
0
0
0
C
0
0
L
0
0
0
0
0
C
0
CCR-38S/CR-38S Page 6  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES  
Insertion Loss ( DC-4 GHz )  
Insertion Loss ( 4-8 GHz )  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
0
1
2
3
4
4
5
6
7
8
Frequency(GHz)  
Frequency(GHz)  
Insertion Loss ( 8-12 GHz )  
Insertion Loss ( 12-16 GHz )  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
8
9
10  
11  
12  
12  
13  
14  
15  
16  
Frequency(GHz)  
Frequency(GHz)  
Insertion Loss ( 16-20 GHz )  
Insertion Loss ( 20-22 GHz )  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
0
-0.1  
-0.2  
-0.3  
-0.4  
-0.5  
-0.6  
-0.7  
-0.8  
-0.9  
-1  
16  
17  
18  
19  
20  
20  
20.5  
21  
21.5  
22  
Frequency(GHz)  
Frequency(GHz)  
18GHZ+ ELITE MODEL ONLY  
RF NOTES  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 7  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES  
Isolation ( DC-4 GHz )  
Isolation ( 4-8 GHz )  
0
-20  
0
-20  
-40  
-40  
-60  
-60  
-80  
-80  
-100  
-120  
-140  
-100  
-120  
-140  
0
1
2
3
4
4
5
6
7
8
Frequency(GHz)  
Frequency(GHz)  
Isolation ( 8-12 GHz )  
Isolation ( 12-16 GHz )  
0
-20  
0
-20  
-40  
-40  
-60  
-60  
-80  
-80  
-100  
-120  
-140  
-100  
-120  
-140  
8
9
10  
11  
12  
12  
13  
14  
15  
16  
Frequency(GHz)  
Frequency(GHz)  
Isolation ( 16-20 GHz )  
Isolation ( 20-22 GHz )  
0
0
-20  
-20  
-40  
-60  
-40  
-60  
-80  
-80  
-100  
-120  
-140  
-100  
-120  
-140  
16  
17  
18  
19  
20  
20  
20.5  
21  
21.5  
22  
Frequency(GHz)  
Frequency(GHz)  
18GHZ+ ELITE MODEL ONLY  
RF NOTES  
CCR-38S/CR-38S Page 8  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES  
VSWR ( DC-4 GHz )  
VSWR ( 4-8 GHz )  
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
0
1
2
3
4
4
5
6
7
8
Frequency(GHz)  
Frequency(GHz)  
VSWR ( 8-12 GHz )  
VSWR ( 12-16 GHz )  
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
8
9
10  
11  
12  
12  
13  
14  
15  
16  
Frequency(GHz)  
Frequency(GHz)  
VSWR ( 16-20 GHz )  
VSWR ( 20-22 GHz )  
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
2
1.9  
1.8  
1.7  
1.6  
1.5  
1.4  
1.3  
1.2  
1.1  
1
16  
17  
18  
19  
20  
20  
20.5  
21  
21.5  
22  
Frequency(GHz)  
Frequency(GHz)  
18GHZ+ ELITE MODEL ONLY  
RF NOTES  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 9  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
TYPICAL POWER PERFORMANCE CURVE  
Power Handling vs. Frequency  
3000  
2000  
1000  
800  
600  
400  
300  
200  
100  
80  
60  
40  
30  
20  
10  
.1  
.2 .3 .4 .6 .8 1  
2
4
6 8 10  
18  
Frequency GHz  
Estimates based on the following reference conditions:  
• Ambient temperature of 40°C or less  
• Sea level operation  
• Load VSWR of 1.20:1 maximum  
• No high-power (hot) switching  
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.  
CCR-38S/CR-38S Page 10  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
GLOSSARY  
Actuator  
TD-Option  
An actuator is the electromechanical mechanism that This option includes a decoder. The 3-bit parallel command  
transfers the RF contacts from one position to another upon is decoded to internally select the appropriate position. See  
DC command.  
the logic tables. The TD-Option increases the Vsw supply  
current demand by 50mA max at 28Vdc and +20°C.  
Arc Suppression Diode  
A diode is connected in parallel with the coil. This diode Performance Parameters vs Frequency  
limits the “reverse EMF spike” generated when the coil de- Generally speaking, the RF performance of coaxial switches  
energizes to 0.7 volts. The diode cathode is connected to is frequency dependent. With increasing frequency, VSWR  
the positive side of the coil and the anode is connected to and insertion loss increase while isolation decreases. All  
the negative side.  
data sheets specify these three parameters as “worst case”  
at the highest operating frequency. If the switch is to be  
used over a narrow frequency band, better performance  
Date Code  
All switches are marked with either a unique serial number can be achieved.  
or a date code. Date codes are in accordance with MIL-  
STD-1285 Paragraph 5.2.5 and consist of four digits. Actuator Current vs Temperature  
The rst two digits dene the year and the last two digits The resistance of the actuator coil varies as a function of  
dene the week of the year (YYWW). Thus, 1032 identies temperature. There is an inverse relationship between the  
switches that passed through nal inspection during the operating temperature of the switch and the actuator drive  
32nd week of 2010.  
current. For switches operating at 28 VDC, the approximate  
actuator drive current at temperature, T, can be calculated  
using the equation:  
Indicator  
Indicators tell the system which position the switch is in.  
Other names for indicators are telemetry contacts or tellback  
circuit. Indicators are usually a set of internally mounted DC  
contacts linked to the actuator. They can be wired to digital  
input lines, status lights, or interlocks. Unless otherwise  
specied, the maximum indicator contact rating is 30 Vdc,  
50 mA, or 1.5 Watts into a resistive load.  
I
A
I
=
T
[1 + .00385 (T-20)]  
Where:  
I
I
=
=
Actuator current at temperature, T  
T
Room temperature actuator current –  
see data sheet  
A
Isolation  
Isolation is the measure of the power level at the output  
connector of an unconnected RF channel as referenced to  
the power at the input connector. It is specied in dB below  
the input power level.  
T
=
Temperature of interest in °C  
Magnetic Sensitivity  
An electro-mechanical switch can be sensitive to ferrous  
materials and external magnetic elds. Neighboring ferrous  
Multi-Throw Switch  
A multi-throw switch is a switch with one input and three or materials should be permitted no closer than 0.5 inches and  
more output ports. The CCR-38 can switch a microwave adjacent external magnetic elds should be limited to a ux  
signal to any of 2,3,4,5 or 6 output from a single common density of less than 5 Gauss.  
input.  
Switching Time  
Switching time is the total interval beginning with the arrival  
of the leading edge of the command pulse at the switch DC  
SPECIAL FEATURE  
Switching High-Power or Highly Sensitive Signals  
Ensure the most linear response with the best galvanically  
matched contact system in the industry. Extremely low  
passive intermodulation is standard on all of our switches.  
input and ending with the completion of the switch transfer,  
including contact bounce. It consists of three parts: (1)  
inductive delay in the coil, (2) transfer time of the physical  
movement of the contacts, and (3) the bounce time of the  
RF contacts.  
Carrier  
Carrier  
PIM 3rd Order  
Frequency  
PIM 5th  
Order Fre-  
quency  
Frequency 1  
Frequency 2  
TTL Switch Driver Option  
As a special option, switch drivers can be provided for both  
failsafe and latching switches, which are compatible with  
industry-standard low-power Schottky TTL circuits.  
870 MHz  
893 MHz  
847 MHz  
824 MHz  
3rd Order  
Intermodulation  
5th Order  
Intermodulation  
–96 dBm  
–115 dBm  
Multiple  
Positions  
–139 dBc  
–158 dBc  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 11  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST  
PART NO.  
PART NO.  
PART NO.  
PART NO.  
1
CCR-38SX3C  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
CR-38SX30  
85  
CR-38SX4C  
127  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
163  
164  
165  
166  
167  
168  
CCR-38SX50  
2
CCR-38SX3C-D  
CCR-38SX3C-DM  
CCR-38SX3C-M  
CCR-38SX3C-MS  
CCR-38SX3C-S  
CCR-38SX3C-T  
CCR-38SX3C-TD  
CCR-38SX3C-TDM  
CCR-38SX3C-TDMS  
CCR-38SX3C-TDS  
CCR-38SX3C-TM  
CCR-38SX3C-TMS  
CCR-38SX3C-TS  
CCR-38SX30  
CR-38SX30-D  
86  
CR-38SX4C-D  
CCR-38SX50-D  
CCR-38SX50-DM  
CCR-38SX50-M  
CCR-38SX50-MS  
CCR-38SX50-S  
CCR-38SX50-T  
CCR-38SX50-TD  
CCR-38SX50-TDM  
CCR-38SX50-TDMS  
CCR-38SX50-TDS  
CCR-38SX50-TM  
CCR-38SX50-TMS  
CCR-38SX50-TS  
CR-38SX5C  
3
CR-38SX30-DM  
CR-38SX30-M  
87  
CR-38SX4C-DM  
CR-38SX4C-M  
CR-38SX4C-MS  
CR-38SX4C-S  
4
88  
5
CR-38SX30-MS  
CR-38SX30-S  
89  
6
90  
7
CR-38SX30-T  
91  
CR-38SX4C-T  
8
CR-38SX30-TD  
CR-38SX30-TDM  
CR-38SX30-TDMS  
CR-38SX30-TDS  
CR-38SX30-TM  
CR-38SX30-TMS  
CR-38SX30-TS  
CCR-38SX4C  
92  
CR-38SX4C-TD  
CR-38SX4C-TDM  
CR-38SX4C-TDMS  
CR-38SX4C-TDS  
CR-38SX4C-TM  
CR-38SX4C-TMS  
CR-38SX4C-TS  
CR-38SX40  
9
93  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
94  
95  
96  
97  
98  
99  
CCR-38SX30-D  
CCR-38SX30-DM  
CCR-38SX30-M  
CCR-38SX30-MS  
CCR-38SX30-S  
CCR-38SX30-T  
CCR-38SX30-TD  
CCR-38SX30-TDM  
CCR-38SX30-TDMS  
CCR-38SX30-TDS  
CCR-38SX30-TM  
CCR-38SX30-TMS  
CCR-38SX30-TS  
CR-38SX3C  
CCR-38SX4C-D  
CCR-38SX4C-DM  
CCR-38SX4C-M  
CCR-38SX4C-MS  
CCR-38SX4C-S  
CCR-38SX4C-T  
CCR-38SX4C-TD  
CCR-38SX4C-TDM  
CCR-38SX4C-TDMS  
CCR-38SX4C-TDS  
CCR-38SX4C-TM  
CCR-38SX4C-TMS  
CCR-38SX4C-TS  
CCR-38SX40  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
CR-38SX40-D  
CR-38SX5C-D  
CR-38SX40-DM  
CR-38SX40-M  
CR-38SX5C-DM  
CR-38SX5C-M  
CR-38SX5C-MS  
CR-38SX5C-S  
CR-38SX40-MS  
CR-38SX40-S  
CR-38SX40-T  
CR-38SX5C-T  
CR-38SX40-TD  
CR-38SX40-TDM  
CR-38SX40-TDMS  
CR-38SX40-TDS  
CR-38SX40-TM  
CR-38SX40-TMS  
CR-38SX40-TS  
CCR-38SX5C  
CR-38SX5C-TD  
CR-38SX5C-TDM  
CR-38SX5C-TDMS  
CR-38SX5C-TDS  
CR-38SX5C-TM  
CR-38SX5C-TMS  
CR-38SX5C-TS  
CR-38SX50  
CR-38SX3C-D  
CCR-38SX40-D  
CCR-38SX40-DM  
CCR-38SX40-M  
CCR-38SX40-MS  
CCR-38SX40-S  
CCR-38SX40-T  
CCR-38SX40-TD  
CCR-38SX40-TDM  
CCR-38SX40-TDMS  
CCR-38SX40-TDS  
CCR-38SX40-TM  
CCR-38SX40-TMS  
CCR-38SX40-TS  
CCR-38SX5C-D  
CCR-38SX5C-DM  
CCR-38SX5C-M  
CCR-38SX5C-MS  
CCR-38SX5C-S  
CCR-38SX5C-T  
CCR-38SX5C-TD  
CCR-38SX5C-TDM  
CCR-38SX5C-TDMS  
CCR-38SX5C-TDS  
CCR-38SX5C-TM  
CCR-38SX5C-TMS  
CCR-38SX5C-TS  
CR-38SX50-D  
CR-38SX3C-DM  
CR-38SX3C-M  
CR-38SX50-DM  
CR-38SX50-M  
CR-38SX3C-MS  
CR-38SX3C-S  
CR-38SX50-MS  
CR-38SX50-S  
CR-38SX3C-T  
CR-38SX50-T  
CR-38SX3C-TD  
CR-38SX3C-TDM  
CR-38SX3C-TDMS  
CR-38SX3C-TDS  
CR-38SX3C-TM  
CR-38SX3C-TMS  
CR-38SX3C-TS  
CR-38SX50-TD  
CR-38SX50-TDM  
CR-38SX50-TDMS  
CR-38SX50-TDS  
CR-38SX50-TM  
CR-38SX50-TMS  
CR-38SX50-TS  
*
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)  
CCR-38S/CR-38S Page 12  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE  
© 2013 TELEDYNE COAX SWITCHES  
CCR-38S\CR-38S\072013\Q3  
Series CCR-38S/CR-38S  
Multi-Throw DC–18 GHz/DC-22 GHz  
Normally Open Coaxial Switch  
COAX SWITCHES  
NORMALLY OPEN CCR-38S/CR-38S PART NUMBER LIST  
PART NO.  
PART NO.  
169  
170  
171  
172  
173  
174  
175  
176  
177  
178  
179  
180  
181  
182  
183  
184  
185  
186  
187  
188  
189  
190  
191  
192  
193  
194  
195  
196  
197  
198  
199  
200  
201  
202  
203  
204  
205  
206  
207  
208  
209  
210  
CCR-38SX6C  
211  
212  
213  
214  
215  
216  
217  
218  
219  
220  
221  
222  
223  
224  
CR-38SX60  
CCR-38SX6C-D  
CCR-38SX6C-DM  
CCR-38SX6C-M  
CCR-38SX6C-MS  
CCR-38SX6C-S  
CCR-38SX6C-T  
CCR-38SX6C-TD  
CCR-38SX6C-TDM  
CCR-38SX6C-TDMS  
CCR-38SX6C-TDS  
CCR-38SX6C-TM  
CCR-38SX6C-TMS  
CCR-38SX6C-TS  
CCR-38SX60  
CR-38SX60-D  
CR-38SX60-DM  
CR-38SX60-M  
CR-38SX60-MS  
CR-38SX60-S  
CR-38SX60-T  
CR-38SX60-TD  
CR-38SX60-TDM  
CR-38SX60-TDMS  
CR-38SX60-TDS  
CR-38SX60-TM  
CR-38SX60-TMS  
CR-38SX60-TS  
CCR-38SX60-D  
CCR-38SX60-DM  
CCR-38SX60-M  
CCR-38SX60-MS  
CCR-38SX60-S  
CCR-38SX60-T  
CCR-38SX60-TD  
CCR-38SX60-TDM  
CCR-38SX60-TDMS  
CCR-38SX60-TDS  
CCR-38SX60-TM  
CCR-38SX60-TMS  
CCR-38SX60-TS  
CR-38SX6C  
CR-38SX6C-D  
CR-38SX6C-DM  
CR-38SX6C-M  
CR-38SX6C-MS  
CR-38SX6C-S  
CR-38SX6C-T  
CR-38SX6C-TD  
CR-38SX6C-TDM  
CR-38SX6C-TDMS  
CR-38SX6C-TDS  
CR-38SX6C-TM  
CR-38SX6C-TMS  
CR-38SX6C-TS  
*
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)  
© 2013 TELEDYNE RELAYS  
(800) 284-7007 • www.teledynecoax.com  
CCR-38S/CR-38S Page 13  
CCR-38S\CR-38S\072013\Q3  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY