DGVR40-5091-S8-3295-R1 [TELEDYNE]

Electric Vehicle Contactor;
DGVR40-5091-S8-3295-R1
型号: DGVR40-5091-S8-3295-R1
厂家: TELEDYNE TECHNOLOGIES INCORPORATED    TELEDYNE TECHNOLOGIES INCORPORATED
描述:

Electric Vehicle Contactor

文件: 总4页 (文件大小:651K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DEVR40  
Electric Vehicle Contactor  
High current and high voltage capability  
• Compact structure - Low noise  
Magnetic arc blowout  
Rated 400A  
Reliable contacts sealed in inert gas  
Coil Economizer & Back EMF protection  
RoHS Compliant  
Power Contacts  
Contact number & arrangement  
Contact material  
SPST-NO (1NO)  
AgSnO2  
Max. switching voltage  
Rated continuous current  
Max. break current  
900VDC (see Figs. 1 & 2)  
400A * (150mm2 busbar, 65°C) , 500A (200mm2 busbar, 65°C)  
2000A (at 320VDC, 1 operation)  
≤60mV@200A)  
Voltage drop  
Optional Auxillary Contacts  
Contact number & arrangement  
Contact material  
SPST-NO (1NO)  
AgSnO2  
Max. contact current  
Min. contact current  
Contact resistance  
2A @ 30VDC / 3A @ 125VAC)  
100mA @ 8VDC  
0.417Ω @ 30VDC / 0.150V @ 125VAC  
Coil  
Rated voltage  
9 ~ 95VDC with Coil Economizer  
See coil data ‘Table 1’  
Operating range of supply voltage  
Insulation  
Insulation resistance (Initial / End of Life)  
Dielectric strength  
100MΩ / 50MΩ at 500VDC (max. current 650VDC)  
coil - contact 2,200Vrms / 4000VDC  
contact - contact 5,000Vrms (leakage current <10mA, 1 minute @ sea level)  
General Data  
Operating time @ 25°C (Operate/Release)  
Electrical life (resistive load, L/R ≤ 1ms)  
Electric vehicle charging circuit  
mS ≤ 25ms. (includes bounce time - 7ms max) / ≤12ms.  
See Fig. 1  
Electrical life @90% capacitive pre-charge (make only 50,000 ops (tested at 320VDC 200uH. Load = 2500A)  
Electrical life @80% capacitive pre-charge (make only 50 ops (tested at 320VDC 200uH. Load = 2500A)  
Mechanical life  
Dimensions  
ops 1 x 106  
L x W x H 80.44 x 65.6 x 72.3mm (see drawings for detail)  
Weight  
430g  
Ambient Temperature  
Shock resistance  
operating / storage -40 to +85°C  
15G, 11ms ½ sine, peak  
Vibration resistance  
15G, sine, peak (80~2,000 Hz)  
* Consult factory for higher current capabilities  
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516  
Page 1 of 4  
www.durakoolrelays.com Sales Department Tel: +1 574 295 6330 Toll: (888) 847 6552  
Specifications are subject to change without notice. E&OE.  
Ref: DEVR40 012516JHM  
DEVR40  
Electric Vehicle Contactor  
Coil Data - DEVR40  
Table 1  
Must Operate  
Voltage Max.  
(VDC)  
Maximum  
Allowable  
Voltage (VDC)  
Must Release  
Voltage Min.  
(VDC)  
Inrush Current Hold Current.  
Coil Voltage  
Code  
Nominal  
Voltage (VDC)  
Hold Voltage  
Min. (VDC)  
Max.  
(A)  
Average  
130mA @ 12VDC  
70mA @ 24VDC  
0936  
9 - 36  
9.0  
36  
6.0  
7.5  
3.8  
30mA @ 48VDC  
20mA @ 72VDC  
3295  
32 - 95  
32  
95  
95  
18.0  
22  
34  
1.3  
0.7  
4895  
48 - 95  
48  
27.0  
Ordering Codes  
D
E
V
R
4
0
-
5
0
6
1
-
S
8
-
-
Contact Material  
50 AgSnO2  
Contact Arrangement  
-
SPST-NO. Polarity Conscious  
61  
71  
81  
91  
-
-
-
-
SPST-NO with aux.contacts. Polarity conscious  
SPST-NO. No Polarity  
SPST-NO with aux. contacts. No Polarity  
Cover Protection and Mounting  
Hermetic sealed, Flange mount  
Connection Mode  
M8 x 10mmm male  
S
-
8
-
Coil Code  
See Coil Data (Table 1)  
Coil Wire Length  
R
T
-
-
380mm (14.96”)  
150mm (5.9”)  
Other lengths available to order  
Coil Wire Termination  
1
-
None  
Other terminations to special order  
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516  
www.durakoolrelays.com Sales Department Tel: +1 574 295 6330 Toll: (888) 847 6552  
Page 2 of 4  
Ref: DEVR40 012516JHM  
Specifications are subject to change without notice. E&OE.  
DEVR40  
Electric Vehicle Contactor  
Electrical Life (Make & Break) Switching (resistive load)  
Fig. 1  
Continuous current v time (secs)  
Fig. 2  
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516  
Page 3 of 4 www.durakoolrelays.com Sales Department Tel: +1 574 295 6330 Toll: (888) 847 6552  
Ref: DEVR40 012516JHM  
Specifications are subject to change without notice. E&OE.  
DEVR40  
Electric Vehicle Contactor  
Overall Dimensions  
Fig. 3  
+ve Coil Wire Red, 22AWG  
Ø 2.4 mm  
Optional auxillary switch wires  
White, 2 x 22AWG Ø 1.2 mm  
-ve Coil Wire Black, 22AWG  
Ø 2.4 mm  
Stainless Steel  
Mounting Hardware (not supplied)  
2 x M5 Bolt  
2 x M5 Lockwasher  
2 x M5 Narrow Washer  
Torque: 15 to 30IN-LB (1.7 to 3NM)  
A1 +VE  
A2 -VE  
Terminal  
Terminal  
All dimensions are in mm  
Notes:  
1)  
2)  
3)  
4)  
6)  
Spring Washers for the power terminals are an essential requirement for installation.  
Torque setting for the M8 Power Terminals is 8.8 to 11Nm. Exceeding the maximum torque may lead to product failure.  
Loose terminals will generate excessive heat leading to premature failure and risk of fire.  
The maximum torque setting for the M5 mounting bolts (not supplied) is 1.7 to 3.3Nm. to avoid damage to the contactor body.  
For polarity conscious versions, please ensure the correct polarity of the wiring to the power terminals. Contact life is greatly  
reduced if the power terminals are incorrectly connected.  
7)  
The contactor coil terminals are polarized. Please ensure they are connected the correctly. This contactor has an Energy  
Optimizer control PCB with an integral surge absorption circuit. external diodes are unneccessary and may degrade  
performance. The Energy Optimizer actuates approximately 0.1s after power is applied to the coil terminals, do not repeat on/  
off or switch off during this time as damge to the contactor may occur. the available coil drive circuit power must exceed the  
contactor coil power requirements.  
8)  
Ensure adequate circuit protection in case of contact malfunction.  
9)  
The contact chamber contains an inert gas. For maximum life, do not exceed the ambient temperature range of -40 to +85°C.  
Contact ratings are based upon a resistive load. For inductive loads an inrush protection device is recommended.  
10)  
11)  
Avoid installing in a strong magnetic field (motor, transformer, external magnet etc.) and protect from heat radiation from nearby  
objects. The contactor coil performance changes with temperature (like all relays and contactors), this might occur from self-  
heating or from an external source, and it will affect the pull-in (operate) performance.  
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516  
Page 4 of 4 www.durakoolrelays.com Sales Department Tel: +1 574 295 6330 Toll: (888) 847 6552  
Ref: DEVR40 012516JHM  
Specifications are subject to change without notice. E&OE.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY