E3PT48A50 [TELEDYNE]
Three-Phase Output to 50A 520 Vac Touch-Proof, AC or DC Control; 三相输出为50A 520伏交流防触摸,交流或直流控制型号: | E3PT48A50 |
厂家: | TELEDYNE TECHNOLOGIES INCORPORATED |
描述: | Three-Phase Output to 50A 520 Vac Touch-Proof, AC or DC Control |
文件: | 总4页 (文件大小:135K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series E3PT
Three-Phase Output to 50A 520 Vac
Touch-Proof, AC or DC Control
Part Number
E3PT48D12
E3PT48A12
E3PT48D50
E3PT48A50
E3PT48D50H
E3PT48A50H
Description
12A, 520 Vac
12A, 520 Vac
50A*, 520 Vac
50A*, 520 Vac
50A*, 520 Vac
50A*, 520 Vac
FEATURES/BENEFITS
E3PT
48
D
50
H
• Designed for all types of loads
• Tight zero-cross window
• Control LED on all models
• Internal output transient protection
• Touch-proof
NOTES
1) Line Voltage (nominal): 48 = 480 Vac
2) Switch Type: D = Zero-cross turn-on
A = AC control, Zero-cross turn-on
3) H = High surge capability
*Current limited to 50A due to terminals
DESCRIPTION
The Series E3PT three-phase solid-state relays are
designed for all types of loads. The E3PT relays
include as a standard a control LED for visual status.
The E3PT series is touch-proof for user safety. An
internal MOV and snubber circuit protect the output
thyristor. The E3PT relays are highly immune to large
current surges. The tight zero-cross window provides
a low EMI level. The E3PT relays are an excellent
choice for three-phase applications.
MECHANICAL SPECIFICATION
3.26 (82.7)
.75
M4
.75
(19) (19)
APPLICATIONS
• Heating control
• Motor control
• Three-phase industrial and process control
3.58 (91)
3.94 (100)
APPROVALS
Series E3PT relays are pending UL recognition.
TYPICAL APPLICATION
R
S
T
R
S
T
R
S
T
WEIGHT: 14.46 oz. (410g)
Figure 1 — E3PT relays; dimensions in inches (mm)
Resistive or
inductive load
M
Figure 2 — E3PT typical application
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
E3PT 1
E3PT\032003\Q1
Series E3PT
INPUT (CONTROL) SPECIFICATION
CONTROL CHARACTERISTIC
Input Type
Min
Max
Units
50
40
30
20
10
Control Range
E3PT48
D
A
8.5
90
30
Vdc
Vac
E3PT48
240
Input Current Range
E3PT48
E3PT48
D
10
4
45
11
mA
mA
A
0
0
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30
Must Turn-off Voltage
Control Voltage (V)
E3PT48
E3PT48
D
A
4
Vdc
Vac
Figure 4a — E3PT48D
15
12
Input Resistance (Typical)
E3PT48
E3PT48
D
A
620
21
Ohms
9
KOhms
6
3
Reverse Voltage Protection
E3PT48
D
30
V
0
0
20 40 60 80 100 120 140 160 180 200 220 240
Control Voltage (V)
Figure 4b — E3PT48A
EQUIVALENT CIRCUIT
L1/R
L1/R
7 +
Adapter
Adapter
U
U
L2/S
LED
A1
A2
L2/S
=
Adapter
Adapter
LED
Adapter
V
V
L3/T
L3/T
Adapter
8 –
W
W
Figure 3a — E3PT48A
Figure 3b — E3PT48D
E3PT 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
E3PT\032003\Q1
Series E3PT
OUTPUT (LOAD) SPECIFICATION
OUTPUT (LOAD) SPECIFICATION (Continued)
Min
Max
Unit
Min
Max
Unit
Operating Range
All relays
Operating Frequency
All relays
24
520
Vrms
10
440
Hz
Peak Voltage
All relays
I2t for Match Fusing (<8.3ms)
E3PT48X12
1200 Vpeak
72
A2s
A2s
A2s
E3PT48X50
5000
Load Current Range (See Note 1)
E3PT48X50H
20,000
E3PT48D12
E3PT48A12
E3PT48D50
E3PT48A50
E3PT48D50H
E3PT48A50H
.005
.005
.005
.005
.005
.005
12
12
A
A
A
A
A
A
ENVIRONMENTAL SPECIFICATION
50*
50*
50*
50*
Min
Max
Unit
Operating Temperature
All relays
-40
100
°C
Storage Temperature
All relays
Maximum Surge Current Rating (Non-Repetitive)
–40
100
°C
E3PT48X12
E3PT48X50
E3PT48X50H
120
1000
2000
A
A
A
Input-Output Isolation
All relays
4000
Vrms
On-State Voltage Drop
All relays
Output-Case Isolation
E3PT48X12
1.4
±12
5
V
V
2500
3300
Vrms
Vrms
All other relays
Zero-Cross Window (Typical)
All relays
NOTES:
1. *Current limited to 50A due to terminals.
2. Electrical specifications at 25°C unless otherwise specified.
Off-State Leakage Current (60Hz)
All relays
mA
Turn-On Time
E3PT48
E3PT48
D
A
8.3
25
ms
ms
Turn-Off Time
E3PT48
D
A
8.3
25
ms
ms
E3PT48
Off-State dv/dt
All relays
500
50
V/µs
A/µs
Maximum di/dt (Non-Repetitive)
All relays
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
E3PT 3
E3PT\032003\Q1
Series E3PT
THERMAL CHARACTERISTICS
SURGE CURRENTS
60
50
40
30
20
10
0
150
100
o
0.95 C/W
Non-Repetitive
1.2 oC/W
50
0
Repetitive with initial Tj = 70oC
0.1
Full on-state
3oC/W
0.01
1
10
t(s)
Figure 6a — E3PT48X12
Without Heat Sink
1500
1000
500
0
2
4
6
8
10
12
0
10 20 30 40 50 60 70 80 90 100
Ambient Temperature (o C)
Non-Repetitive
Load Current (A)
Repetitive with initial Tj = 70oC
Figure 5a — E3PT48X12
0
0.01
0.1
1
10
t(s)
300
280
260
240
220
200
180
160
140
120
100
80
Figure 6b — E3PT48X50
Full on-state
0.3°C/W
0.55°C/W
0.95°C/W
2000
1500
1000
500
Non-Repetitive
Repetitive with initial Tj = 70oC
0
0.01
0.1
1
10
60
1.2°C/W
t(s)
40
Without Heat Sink
20
Figure 6c — E3PT48X50H
0
0
10 20 30 40 50 60 70 80
Load Current (A)
0
10 20 30 40 50 60 70 80 90 100
Ambient Temperature (o C)
Figure 5b — E3PT48X50
140
120
100
80
0.5°C/W
0.3°C/W
0.55°C/W
Full on-state
0.9°C/W
60
1.2°C/W
40
Without Heat Sink
20
0
0
5
10 15 20 25 30 35 40 45 50
Load Current (A)
0
10 20 30 40 50 60 70 80 90 100
Ambient Temperature (oC)
Figure 5c — E3PT48X50H
E3PT 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
E3PT\032003\Q1
相关型号: