SSH48D75 [TELEDYNE]
Output to 75A, 510 Vac with Diagnostics;![SSH48D75](http://pdffile.icpdf.com/pdf2/p00337/img/icpdf/SSH48D50_2074199_icpdf.jpg)
型号: | SSH48D75 |
厂家: | ![]() |
描述: | Output to 75A, 510 Vac with Diagnostics 输出元件 光电 |
文件: | 总5页 (文件大小:859K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
NEW Series SSH
Output to 75A, 510 Vac with Diagnostics
High Industrial Performance (HIPpak) Solid-State Relays
FEATURES/BENEFITS
• Zero-cross models with system diagnostics
• Very low zero-cross turn-on voltage
• Input and output protection and control LED standard
• IP20 protection by flaps on terminals
• With double removable input connectors; spring terminals
• Designed in conformity with EN60947-4-3 (IEC947-4-3)
and EN60950/VDE0805 (Reinforced Insulation)
Two removable
input connectors
with spring
Grey: Control
Orange: Status
MECHANICAL SPECIFICATION
Load
Voltage
Load
Current
Control
Voltage
Switch
Type
Part No.
�ꢀꢍꢍ
ꢂꢌꢋꢅꢆꢇꢈꢉ
SSH24D35 50-265 Vac
SSH24D50 24-265 Vac
SSH48D50 24-510 Vac
SSH48D75 24-510 Vac
35A
50A
50A
75A
7-30 Vdc
7-30 Vdc
7-30 Vdc
7-30 Vdc
Zero Cross
Zero Cross
Zero Cross
Zero Cross
TYPICAL APPLICATION
ꢣꢃꢕꢄꢋ
ꢗ�
ꢘꢙ
�ꢀꢁ�
ꢤꢈ
ꢥꢈ
ꢊꢄꢀ�ꢁꢋ
ꢂꢌꢀꢍꢅ
�ꢀ�ꢁ
ꢂꢃꢄꢅꢆꢇꢈꢉ
ꢢꢑꢋꢊ
�ꢀ�ꢄꢆꢂꢎꢁꢅ
ꢦꢓꢄꢒꢟꢓꢡ
ꢚꢛ
ꢗꢆ
ꢞꢟꢊꢊꢄ
ꢥꢋ
ꢥꢅꢋ
ꢤꢅ
ꢝꢙ
ꢜꢛ
ꢁꢓꢃꢅ
ꢠꢊꢡꢡꢓꢌ
ꢎꢒꢃꢒꢑꢋ
ꢧꢑꢒꢍꢑꢒ
ꢆꢀꢇ�
�ꢘꢙ�
ꢎꢘꢛ�
ꢨꢥꢀꢥꢋ
ꢐꢑꢒꢓꢔꢑꢕ
ꢖꢆꢆꢆꢆꢗ
ꢜꢓꢈꢓꢝꢞ
ꢖꢆꢆꢆꢆꢗ
�ꢀꢁ�ꢂꢃꢄꢅꢂꢆꢀꢇ�ꢂꢈꢃꢄꢂꢉꢊꢂꢋꢌꢃꢍꢍꢊꢅ
ꢎꢎꢏꢂꢐꢑꢋꢒꢂꢉꢊꢂꢐꢓꢑꢄꢒꢊꢅꢂꢓꢄꢂꢃꢂꢔꢊꢃꢒꢂꢋꢕꢄꢖ
Figure 1 — SSH relays
�ꢀꢃꢎ
ꢂꢃꢃꢀꢏꢅ
CONTROL CHARACTERISTICS
ꢠꢡꢓꢢꢑꢝꢓꢆꢣꢈꢝꢕꢓꢞꢆꢓꢢꢤꢆꢞꢓꢈꢓꢝꢞꢆꢡꢞꢆꢥꢀꢐꢀ
ꢃ�
ꢂꢀ
ꢂ�
ꢁꢀ
ꢁ�
ꢀ
Figure 2 — SSH relays
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
INPUT (CONTROL) SPECIFICATIONS
Min
Max
28
Units
mA
Vdc
V
Input Current Range
Must Turn-Off Voltage
Reverse Voltage Protection
Input Resistor (Typ)
4
3.0
30
�
1000
Ω
�
ꢀ
ꢁ�
ꢁꢀ
ꢂ�
ꢂꢀ
ꢃ�
ꢃꢀ
�ꢀꢁꢂꢃꢀꢄꢅꢆꢀꢄꢂꢇꢈꢉꢅꢊꢆꢋ
Figure 3 — SSH relays
© 2005 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
SSH Page 1
SSH\042005\Q1
NEW Series SSH
Output to 75A, 510 Vac with Diagnostics
High Industrial Performance (HIPpak) Solid-State Relays
OUTPUT (LOAD) SPECIFICATIONS
Conducted Immunity Level
Min
Max
Units
IEC/EN61000-4-4 (bursts)
IEC/EN61000-4-5 (bursts)
2kV criterion A
Peak Voltage
SSH24DXX
SSH48DXX
2kV criterion A
with external VDR
600
Vpeak
1200 Vpeak
GENERAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
ENVIRONMENTAL SPECIFICATIONS
Load Currrent Range (Resistive)
35 output current
Min
–40
–40
Max
+100
+100
85
Units
°C
.005
.005
.005
40
60
90
Arms
Arms
Arms
Operating Temperature
Storage Temperature
Ambient Humidity
50 output current
°C
75 output current
%
Input-Output Isolation
Output-Case Isolation
Output-Status Isolation
Input-Status Isolation
4000
4000
2500
2500
Vrms
Vrms
Vrms
Vrms
Maximum Surge Current Rating (Non-Repetitive)
35 output current
50 output current
75 output current
500
720
A
A
A
1200
Insulation Resistance
@500Vdc
1000
MΩ
On-State Voltage Drop
0.9
V
Rated Impulse Voltage
4000
IP20
V
Protection Level (CEI529)
Output Power Dissipation (Max)
Vibration (10–55 Hz according to CE168) 1.5
mm
g
35 output current
0.9x0.9xI + 0.015xI2
0.9x0.9xI + 0.012xI2
W
W
W
Shock (according to CE168)
Housing Material
30/50
PA6 UL94VO
50 output current
75 output current 0.9x0.9xI + 0.0045xI2
Baseplate
Aluminum, nickel-plated
SURGE CURRENT
Zero-Cross Window (Typical)
Off-State Leakage Current
Turn-On Time (60 Hz)
Turn-Off Time (60 Hz)
Off-State dv/dt
±12
5
Vac
mA
ms
ꢄꢀꢀ
ꢃꢀꢀ
ꢂꢀꢀ
�ꢀꢀ
ꢅꢆꢇꢈꢉꢊꢋꢊꢌꢍꢌꢍꢎꢊ
8.3
8.3
500
50
ms
ꢉꢊꢋꢊꢌꢍꢌꢍꢎꢊꢏꢐꢍꢌꢑꢏꢍꢇꢍꢌꢍꢒꢓꢏꢔꢕꢏꢖꢏꢗꢀꢘꢙ
ꢀꢁ�
V/µs
A/µs
Hz
ꢀ
ꢀ
�
�ꢀ
Maximum di/dt (Non-Repetitive)
Operating Frequency
�ꢀꢁꢂ
Figure 4a — 35A output current
0.1
400
ꢄꢀꢀ
ꢃꢀꢀ
ꢂꢀꢀ
I2t for fuse matching (<10ms)
35 output current
ꢅꢆꢇꢈꢉꢊꢋꢊꢌꢍꢌꢍꢎꢊ
1250
2500
7200
A2s
A2s
A2s
ꢉꢊꢋꢊꢌꢍꢌꢍꢎꢊꢏꢐꢍꢌꢑꢏꢍꢇꢍꢌꢍꢒꢓꢏꢔꢕꢏꢖꢏꢗꢀꢘꢙ
50 output current
ꢀ
ꢀ
ꢀꢁ�
�
�ꢀ
75 output current
�ꢀꢁꢂ
Figure 4b — 50A output current
�ꢂꢀꢀ
�ꢀꢀꢀ
ꢂꢀꢀ
Junction-Case Thermal Resistance
35 output current
0.6
0.45
0.4
°C/W
°C/W
°C/W
ꢃꢄꢅꢆꢇꢈꢉꢈꢊꢋꢊꢋꢌꢈ
50 output current
75 output current
ꢇꢈꢉꢈꢊꢋꢊꢋꢌꢈꢍꢎꢋꢊꢏꢍꢋꢅꢋꢊꢋꢐꢑꢍꢒꢓꢍꢔꢍꢕꢀꢖꢗ
ꢀ
ꢀ
ꢀꢁ�
�
�ꢀ
�ꢀꢁꢂ
Figure 4c — 75A output current
SSH Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2005 TELEDYNE RELAYS
SSH\042005\Q1
NEW Series SSH
Output to 75A, 510 Vac with Diagnostics
High Industrial Performance (HIPpak) Solid-State Relays
THERMAL CURVES
STATUS OUTPUT ANSWER CHARACTERISTICS
Min
Max
32
Units
V
ꢅ�
ꢀ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
�
ꢁꢔꢁꢕꢖꢗꢘ
ꢅ�
ꢀ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
�
�ꢔꢆꢀꢕꢖꢗꢘ
Voltage Range
1
ꢁꢔꢀꢕꢖꢗꢘ
ꢂꢔꢁꢕꢖꢗꢘ
ꢉꢊꢋꢋꢌꢍꢎꢌꢏꢐꢑꢐꢒ
Output Current
0.1
2
A
On Resistance
Ω
Open Delay (to1) (faults)
70
ms
ms
ms
m
ꢄꢕꢖꢗꢘ
ꢅꢕꢖꢗꢘ
Total Open Delay (to2) (faults) 120
Close Main Delay (tc1) (tc2)
ꢁꢂꢕꢖꢗꢘ
20
30
ꢀ�ꢓꢌꢍꢎꢌꢏꢐꢑꢐꢒ
Maximum Cable Length for Open Load
�
ꢀ
ꢁ� ꢁꢀ ꢂ� ꢂꢀ ꢃ� ꢃꢀ ꢄ�
�
ꢁ� ꢂ� ꢃ� ꢄ� ꢀ� ꢅ� ꢆ� ꢇ� ꢈ� ꢁ��
�ꢀꢁꢂꢃꢄꢅꢆꢆꢇꢈꢉꢃꢊꢋꢆꢌꢍꢎ
ꢋꢌꢕꢒꢇꢈꢉꢃꢖꢇꢌꢓꢇꢆꢁꢉꢅꢆꢇꢃꢊꢗꢄꢎ
DIAGNOSTIC DESCRIPTION
Figure 5a — 35A output power
Control
LED
Output Output
Control
Main
Load
SSR
ꢁ��
ꢈ�
ꢇ�
ꢆ�
ꢅ�
ꢀ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
�
ꢁ��
ꢈ�
ꢇ�
ꢆ�
ꢅ�
ꢀ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
�
LED
Status
Open
Open
�ꢔꢆꢀꢕꢖꢗꢘ
�ꢔꢈꢀꢕꢖꢗꢘ
�ꢔꢀꢀꢕꢖꢗꢘ
0
1
●
●
No
No
x
x
x
x
●
●
ꢁꢔꢁꢕꢖꢗꢘ
ꢁꢔꢀꢕꢖꢗꢘ
ꢉꢊꢋꢋꢌꢍꢎꢌꢏꢐꢑꢐꢒ
0
1
●
●
Yes
Yes
OK
OK
OK
OK
●
●
Closed
Closed
ꢂꢔꢁꢕꢖꢗꢘ
0
0
1
1
●
●
●
●
Yes
Yes
Yes
Yes
Open
OK
OK
●
●
●
●
Open
Open
Open
Open
ꢅꢕꢖꢗꢘ
Short-Circuit
OK
ꢀ�ꢓꢌꢍꢎꢌꢏꢐꢑꢐꢒ
Open
OK
Short-Circuit
�
ꢀ
ꢁ� ꢁꢀ ꢂ� ꢂꢀ ꢃ� ꢃꢀ ꢄ� ꢄꢀ ꢀ� ꢀꢀ ꢅ�
�
ꢁ� ꢂ� ꢃ� ꢄ� ꢀ� ꢅ� ꢆ� ꢇ� ꢈ� ꢁ��
�ꢀꢁꢂꢃꢄꢅꢆꢆꢇꢈꢉꢃꢊꢋꢆꢌꢍꢎ
ꢋꢌꢕꢒꢇꢈꢉꢃꢖꢇꢌꢓꢇꢆꢁꢉꢅꢆꢇꢃꢊꢗꢄꢎ
Figure 6 — SSH relays
Figure 5b — 50A output power
ꢀꢀ�
ꢀ��
ꢈ�
ꢇ�
ꢆ�
ꢅ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
ꢀ�
�
ꢀꢀ�
ꢀ��
ꢈ�
ꢇ�
ꢆ�
ꢅ�
ꢄ�
ꢃ�
ꢂ�
ꢁ�
ꢀ�
�
DIAGNOSTICS OVERVIEW
�ꢔꢄꢄꢕꢖꢗꢘ �ꢔꢂꢕꢖꢗꢘ
�ꢔꢆꢄꢕꢖꢗꢘ
�ꢔꢈꢄꢕꢖꢗꢘ
ꢊꢋꢌꢍꢎ�ꢏꢐꢍ
�ꢀꢁꢂ
ꢉꢊꢋꢋꢌꢍꢎꢌꢏꢐꢑꢐꢒ
ꢀꢔꢀꢕꢖꢗꢘ
ꢀꢔꢄꢕꢖꢗꢘ
ꢁꢔꢀꢕꢖꢗꢘ
ꢊꢂ
ꢃꢄꢂꢅꢆꢄꢇ
ꢊꢚꢚ
ꢑꢒꢊꢓꢔꢕꢃꢐꢓꢃꢖꢐꢔ
ꢊꢍꢎꢊꢖꢔꢋꢖꢔ
ꢊꢋꢌꢍꢎꢗꢊꢏꢘ
ꢃꢈꢆꢆꢉꢂꢅ
ꢅꢄꢂ
ꢅꢟꢝ
ꢅꢄꢚꢚ
ꢄ�ꢓꢌꢍꢎꢌꢏꢐꢑꢐꢒ
ꢑꢅꢀꢅꢈꢛꢎꢄꢈꢅꢙꢈꢅ ꢎ
ꢊꢙꢉꢂ
ꢃꢇꢄꢛꢉꢜ
ꢅꢕꢖꢗꢘ
ꢅꢟꢝ
ꢅꢄꢝ
ꢅꢄꢞ
ꢅꢄꢝ
ꢅꢄꢞ
ꢅꢟꢞ
ꢅꢄꢝ
ꢅꢄꢞ
�
ꢀ� ꢁ� ꢂ� ꢃ� ꢄ� ꢅ� ꢆ� ꢇ� ꢈ�
�
ꢀ� ꢁ� ꢂ� ꢃ� ꢄ� ꢅ� ꢆ� ꢇ� ꢈ� ꢀ��
�ꢀꢁꢂꢃꢄꢅꢆꢆꢇꢈꢉꢃꢊꢋꢆꢌꢍꢎ
ꢋꢌꢕꢒꢇꢈꢉꢃꢖꢇꢌꢓꢇꢆꢁꢉꢅꢆꢇꢃꢊꢗꢄꢎ
ꢃꢄꢂꢅꢆꢄꢇꢎꢗꢌꢘ
ꢊꢈꢅꢙꢈꢅꢎꢗꢌꢘꢎꢎ
Figure 5c — 75A output power
12°C/W corresponds to a relay without heat sink
6°C/W corresponds to a relay mounted on a DIN-rail adaptor
(Teledyne P/N DL12)
•
•
Output status is normally closed without failure on the relay and the
load. The output LED is normally ON:
In case of failure on the load (open) or on the SSR (short-circuit condi-
tion):
- the status is open
- the output LED is switched OFF
Figure 7 — SSH relays
© 2005 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
SSH Page 3
SSH\042005\Q1
NEW Series SSH
Output to 75A, 510 Vac with Diagnostics
High Industrial Performance (HIPpak) Solid-State Relays
CONTROL WIRING
With double removeable input connector
Pluggable spring connector
Min AWG28
Max AWG14
Option clip
POWER WIRING
Number of Wires
Screwdriver
Type
Recommended
Torque
1
2
Solid
(no ferrule)
Fine Stranded
(with ferrule)
Solid
(no ferrule)
Fine Stranded
(with ferrule)
N.m
1.2
AWG16…AWG8 AWG16…AWG10 AWG16…AWG8 AWG16…AWG10
Pozidriv 2
OPTIONAL CONNECTIONS
Directly with wires,
with or without ferrules
With tips
(ring terminals)
Power with tips
Options
AWG6
16mm2
Fastons: Call us
AWG4
16mm2
W max = 13mm
AWG0
50mm2
for high current
SSH Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2005 TELEDYNE RELAYS
SSH\042005\Q1
NEW Series SSH
Output to 75A, 510 Vac with Diagnostics
High Industrial Performance (HIPpak) Solid-State Relays
2–2.5°C/W
Teledyne P/N FW151
1.1°C/W
Teledyne P/N FW108
0.3°C/W
Teledyne P/N FW031
Mounting
HIPpak SSRs must be mounted on heat
sinks. A large range of heat sinks is
available. For heat-sink mounting, use
thermal grease or a thermal pad with high
conductibility specified by Teledyne.
DIN Rail Adapter
Teledyne P/N DL12
Thermal Pad
Teledyne P/N –12
Typical Loads
SHH relays with zero-cross turn-on are designed for most types of loads.
Our data sheet lists the AC-51 current value corresponding to resistive loads.
For other loads, check the inrush current at turn ON and possible overvoltages at turn OFF:
• AC-55b — Incandescent lamps. Inrush current is generally 10 times In during few 10ms.
• AC-55a — Electric discharge lamp. These loads often have overcurrent at turn ON and overvoltage at turn OFF, so use 400VAC
SSR on 230VAC mains.
• AC-58 — One-pole motors. These loads often have overcurrent at turn ON and overvoltage at turn OFF, so use 400VAC SSR on
230VAC mains and adapt the SSR current to the starting current of the motor.
• AC-53 — Three-phase motors. 2 or 3 SH zero-cross relays can drive these motors, but generally use E3P/E3PT or other three-
phase relays or SH random range.
• AC-56a — Transformer loads. Very high inrush current up to 100 times In. Use SH random relay or peak control SSR.
• AC-56b — Capacitor loads with very high current at turn ON and overvoltage at turn OFF. Our high-voltage relays are well adapted
for high inrush current.
Protection
• To protect the SSR against a short-circuit of the load, use a fuse with a I2t value = 1/2 I2t value specified.
EMC
Immunity:
• Our data sheets list the immunity level of our SSRs according to the main standards for these of products: IEC/EN61000-4-4 and
IEC/EN61000-4-5.You can compare the high immunity level with other products on the market.
Emission:
• Teledyne SSRs are designed in compliance with standards for class A equipment (Industry).
• Use of this product in domestic environments may cause radio interference. In this case the user may be required to employ
additional devices to reduce noise. SSRs are complex devices that must be interconnected with other equipment (loads, cables,
etc.) to form a system. Because the other equipment or interconnections may not be under Teledyne’s control, it shall be the
responsibility of the system integrator to ensure that systems containing SSRs comply with the requirement of any rules and
regulations applicable at the system level.
• The very low zero-cross voltage of SSH relays (<12 volts) improved the conducted emission level in comparison with most SSRs
on the market with zero-cross voltage often higher than 50 volts.
© 2005 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
SSH Page 5
SSH\042005\Q1
相关型号:
![](http://pdffile.icpdf.com/pdf2/p00261/img/page/SSH60N06_1577691_files/SSH60N06_1577691_1.jpg)
SSH4N55
Power Field-Effect Transistor, 4A I(D), 550V, 3ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-3P, 3 PIN
SAMSUNG
![](http://pdffile.icpdf.com/pdf2/p00242/img/page/SSH4N60A_1468330_files/SSH4N60A_1468330_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00242/img/page/SSH4N60A_1468330_files/SSH4N60A_1468330_2.jpg)
SSH4N60
Power Field-Effect Transistor, 4A I(D), 600V, 3ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-3P, 3 PIN
SAMSUNG
![](http://pdffile.icpdf.com/pdf2/p00242/img/page/SSH4N60A_1468330_files/SSH4N60A_1468330_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00242/img/page/SSH4N60A_1468330_files/SSH4N60A_1468330_2.jpg)
SSH4N60A
Power Field-Effect Transistor, 4A I(D), 600V, 2.5ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-3P, 3 PIN
SAMSUNG
![](http://pdffile.icpdf.com/pdf2/p00286/img/page/SSH4N90AS_1714885_files/SSH4N90AS_1714885_1.jpg)
![](http://pdffile.icpdf.com/pdf2/p00286/img/page/SSH4N90AS_1714885_files/SSH4N90AS_1714885_2.jpg)
SSH4N90AS
Power Field-Effect Transistor, 4.5A I(D), 900V, 3.7ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-3P, 3 PIN
FAIRCHILD
![](http://pdffile.icpdf.com/pdf2/p00261/img/page/SSH60N06_1577691_files/SSH60N06_1577691_1.jpg)
SSH60N06
Power Field-Effect Transistor, 60A I(D), 60V, 0.03ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-3P, 3 PIN
SAMSUNG
©2020 ICPDF网 联系我们和版权申明