Bt8960  
Software Users Guide  
100251B  
September 2000  
© 1996, 2000, Conexant Systems, Inc.  
All Rights Reserved.  
Information in this document is provided in connection with Conexant Systems, Inc. (“Conexant”) products. These materials are  
provided by Conexant as a service to its customers and may be used for informational purposes only. Conexant assumes no  
responsibility for errors or omissions in these materials. Conexant may make changes to specifications and product descriptions at  
any time, without notice. Conexant makes no commitment to update the information and shall have no responsibility whatsoever for  
conflicts or incompatibilities arising from future changes to its specifications and product descriptions.  
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as  
provided in Conexant’s Terms and Conditions of Sale for such products, Conexant assumes no liability whatsoever.  
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING  
TO SALE AND/OR USE OF CONEXANT PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A  
PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY  
PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. CONEXANT FURTHER DOES NOT WARRANT THE  
ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE  
MATERIALS. CONEXANT SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL  
DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE  
OF THESE MATERIALS.  
Conexant products are not intended for use in medical, lifesaving or life sustaining applications. Conexant customers using or selling  
Conexant products for use in such applications do so at their own risk and agree to fully indemnify Conexant for any damages  
resulting from such improper use or sale.  
The following are trademarks of Conexant Systems, Inc.: Conexant™, the Conexant C symbol, and “What’s Next in Communications  
Technologies”™. Product names or services listed in this publication are for identification purposes only, and may be trademarks of  
third parties. Third-party brands and names are the property of their respective owners.  
For additional disclaimer information, please consult Conexant’s Legal Information posted at www.conexant.com, which is  
incorporated by reference.  
Reader Response: Conexant strives to produce quality documentation and welcomes your feedback. Please send comments and  
suggestions to tech.pubs@conexant.com. For technical questions, contact your local Conexant sales office or field applications  
engineer.  
100251B  
Conexant  
Preliminary Information/Conexant Proprietary and Confidential  
Table of Contents  
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix  
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi  
1.0  
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1  
1.1 How to Use this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3  
1.2 Contents of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4  
2.0  
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
2.1 Software Structure and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
2.2 Portability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
2.3 Integration with Application-Specific Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
2.4 Software Interfacing with the Bt8960. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3  
3.0  
Software Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1  
3.1 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1  
3.2 Setting Bit-Pump Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2  
3.3 Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3  
3.4 Test Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5  
3.5 Internal BER Meter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7  
3.5.1  
Calculating Avg BER and Elapsed Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7  
4.0  
5.0  
Software Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1  
4.1 Software Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1  
4.2 User-Called Routines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3  
4.3 Memory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4  
Compiling the Source Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1  
5.1 Directory Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1  
5.2 File Names and Dependencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2  
5.2.1  
5.2.2  
Compilation Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3  
Code Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5  
100251B  
Conexant  
iii  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Software Users Guide  
6.0  
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1  
6.1 Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
6.2 Serial Communication Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
6.2.1  
6.2.2  
6.2.3  
6.2.4  
Communication Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
Message Transfer Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
Message Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6  
Checksum Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7  
6.3 Code Level Interface (API) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8  
6.3.1  
6.3.2  
6.3.3  
_BtControl(). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8  
_BtStatus() . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9  
User Defined API Commands - Channel Unit & Framer . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9  
6.4 Opcodes and Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11  
Appendix A Command Set Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1  
A.1 Control Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1  
A.1.1  
A.1.2  
A.1.3  
A.1.4  
A.1.5  
A.1.6  
A.1.7  
A.1.8  
A.1.9  
Terminal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1  
Analog AGC Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2  
Start-up Sequence Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3  
Transmit Scrambler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4  
Receive Descrambler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5  
Data Transfer Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6  
Other Side Bt8960 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7  
LOST Time Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7  
Bit-pump ON/OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8  
A.1.10 Transmit External Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8  
A.1.11 Activate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9  
A.1.12 Deactivate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9  
A.1.13 Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10  
A.1.14 Symbol Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12  
A.1.15 Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12  
A.1.16 Operate Non-Linear EC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13  
A.1.17 Write Transmitter Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-13  
A.1.18 Tip/Ring Reversal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14  
A.1.19 BER Meter Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-14  
A.1.20 BER Meter Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-15  
iv  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Software Users Guide  
A.2 Status Request Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16  
A.2.1  
A.2.2  
A.2.3  
A.2.4  
A.2.5  
A.2.6  
A.2.7  
A.2.8  
A.2.9  
Input Signal Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16  
Input DC Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-16  
Far-End Signal Attenuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-17  
Noise Margin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-18  
Timing Recovery Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-18  
Bit-Pump Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-19  
Read Linear Echo Canceler Coefficient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-20  
Read Non-Linear Echo Canceler Coefficient. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-21  
Read EQ Coefficient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-21  
A.2.10 Read DFE Coefficient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-22  
A.2.11 Software/Chip Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-23  
A.2.12 Bit-pump Present. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-24  
A.2.13 Self Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-24  
A.2.14 Read Bt8960 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-25  
A.2.15 Bit-pump Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-25  
A.2.16 Stage Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-26  
A.2.17 AAGC Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-27  
A.2.18 Read Tx Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-27  
A.2.19 BER Meter Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-28  
A.3 Special Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-29  
A.3.1  
Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-29  
Appendix B Calibrating Noise Margin Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1  
B.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1  
B.1.1  
B.1.2  
Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1  
Noise Margin Table Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1  
Appendix C ERLE Diagnostic Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1  
C.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1  
C.2 What is ERLE? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1  
C.3 ERLE Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2  
C.3.1  
C.3.2  
_ERLE(). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2  
_MeasureAagc(). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2  
C.4 Invoking the Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
C.4.1  
C.4.2  
C.4.3  
Background Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
ERLE and Analog ERLE Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
AAGC Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
C.5 Compiling the ERLE Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
C.5.1 TDEBUG Compiler Flag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3  
100251B  
Conexant  
v
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Software Users Guide  
Appendix D Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1  
D.1 Memory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1  
D.1.1 Bug Fixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2  
D.1.2 Support new Bt8960 Rev C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2  
D.1.3 Improved Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3  
D.1.4 New / Modified Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3  
D.1.5 New API Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4  
D.1.6 Internal BER Meter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6  
D.1.7 BER Meter Bit-pump Code Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8  
D.2 Bt8960 Bit-pump Version 1.1, Release Notes—September 2, 1996 . . . . . . . . . . . . . . . . . . . . . D-9  
D.2.1 PLL Modes CLK_FREQ Bits were Incorrect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9  
D.2.2 Added ERLE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9  
D.2.3 Bt8960EVM Single Board Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9  
Appendix E Version 1.1 Release Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1  
E.1 PLL Modes CLK_FREQ Bits were Incorrect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1  
E.2 Added ERLE Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2  
E.3 Bt8960EVM Single Board Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2  
E.3.1  
E.3.2  
E.3.3  
USER.C - Different Bit-pump Address Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2  
SCRIPT.BLD - XDATA Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2  
Application Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-2  
vi  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Software Users Guide  
100251B  
Conexant  
vii  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Software Users Guide  
viii  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
List of Figures  
Software Users Guide  
List of Figures  
Figure 3-1.  
Figure 4-1.  
Figure 5-1.  
Figure 6-1.  
Figure 6-2.  
Figure 6-3.  
Figure 6-4.  
Figure 6-5.  
Figure D-1.  
Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8  
Bt8960 Software Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1  
User-Modifiable Code Section Format. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5  
Two Microprocessors Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1  
Single Microprocessor Implementation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Host Processor to 8032 Message Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6  
8032 to Host Processor Message Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7  
Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-7  
100251B  
Conexant  
ix  
Preliminary Information/Conexant Proprietary and Confidential  
List of Figures  
Bt8960  
Software Users Guide  
x
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
List of Tables  
Software Users Guide  
List of Tables  
Table 3-1.  
Table 3-2.  
Table 3-3.  
Table 3-4.  
Table 3-5.  
Table 4-1.  
Table 4-2.  
Table 5-1.  
Table 6-1.  
Table 6-2.  
Table 6-3.  
Table A-1.  
Table A-2.  
Table A-3.  
Table A-4.  
Table A-5.  
Table D-1.  
Table D-2.  
User Configurable Parameters and their Default Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2  
Start-up Status Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4  
Additional Status Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4  
Bt8960 Test Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5  
Analog Loopback vs. Version Relationships. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6  
Bt8960 Software Routines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3  
Memory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4  
Source File Names and Dependencies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2  
Destination Field Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Destination Field Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10  
User Interface Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11  
Bt8960 AGAIN Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3  
Exiting Test Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-10  
Status Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-20  
Low Application Setup Byte. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-26  
High Application Setup Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-26  
RAM and ROM Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1  
Version Relationships . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3  
100251B  
Conexant  
xi  
Preliminary Information/Conexant Proprietary and Confidential  
List of Tables  
Bt8960  
Software Users Guide  
xii  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
1
1.0 Introduction  
The Bt8960 Single Chip 2B1Q Transceiver (also referred to as bit-pump) chip is  
designed to be controlled by an external microprocessor. The microprocessor sets  
and controls all Bt8960 internal operation modes during activation, monitors the  
bit-pumps performance during normal operation, and implements steady-state  
activities such as micro-interruptions recovery.  
A single processor may control up to six bit-pump chips. The Bt8960 software  
implements all the necessary bit-pump control and monitoring operations,  
including activation process, performance monitoring, and test modes. This  
software package is an integral part of the Bt8960 bit-pump, and must be used  
without any significant changes in order to guarantee correct operation and  
optimal bit-pump performance.  
The software is supplied in both C source code format and Intel 8032 object  
code format. The object code software may be used in a system employing Intels  
8032 controller to control the Bt8960 chip, or in a specific hardware configuration  
which employs a second “host” processor that runs the user code and  
communicates with the 8032 through the serial communication channel (similar to  
Brooktrees HDSL EVM system). Such a design will require no user code  
modifications.  
If a non-8032 processor is used, or if an 8032-based system implements  
different hardware design, the C source code version should be compiled together  
with necessary modifications for the target processor of choice.  
A major design goal for the Bt8960 software is portability and ease of  
conversion for different hardware and compiler environments. However, this  
cannot completely eliminate the need to “tune” the software for specific  
implementations because of the hardware-dependent nature of the code. This  
manual includes detailed instructions to allow for modification of this code.  
All application interactions with the Bt8960 are done via a user interface  
protocol, which is implemented either at the code level (for applications  
integrating the software in a “single processor” configuration) or by using a serial  
communication channel (for systems employing an 8032 controller and an  
additional host processor in a “dual processor” configuration).  
The Bt8960 software is conceptually broken up into two sections of code:  
Application Code and Bit-pump Code.  
The application code section is inevitably the responsibility of the end user.  
Brooktree offers a complete evaluation system (EVM) which implements an  
example of this application code. To obtain the evaluation system, contact your  
local sales representative.  
100251B  
Conexant  
1-1  
Preliminary Information/Conexant Proprietary and Confidential  
1.0 Introduction  
Bt8960  
Software Users Guide  
The Bt8960 bit-pump software handles the complete activation process without any need for  
application intervention. All bit-pumps may go through activation in parallel, with practically no  
degradation of activation time.  
The user interface allows access to all parameter status required to implement an HDSL system,  
including noise margin, pulse attenuation, loss of signal (LOS), etc.  
Although no DSP tasks are performed by the control software, some sections of the code  
involve real-time operations, especially during activation. Applications that integrate the Bt8960  
software should take this into account and follow the software integration instructions.  
1-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
1.0 Introduction  
Software Users Guide  
1.1 How to Use this Manual  
1.1 How to Use this Manual  
This manual contains all the necessary information required to successfully modify, compile, and  
use the Bt8960 software. It is highly recommended that this manual is read prior to writing  
application code for the Bt8960.  
The chapters Software Structurethrough Software Integrationare particularly important  
for those using the source code version of the software to integrate the code with their own software.  
Use the Compiling the Source Codechapter when modifying and compiling the source code.  
Refer to the Software Integrationchapter when integrating the application software with the  
Bt8960 code.  
The Bt8960 is controlled using the software user interface. Use the detailed information given  
in the User Interfacechapter when writing the Bt8960 application software. Appendix A serves as  
a reference to the control and status command set.  
The Software Applicationchapter contains information on how to use the Bt8960 software  
and User Interface command set in a transceiver application. It outlines the required initialization  
and parameter setting sequence, accompanied by examples of a typical application.  
100251B  
Conexant  
1-3  
Preliminary Information/Conexant Proprietary and Confidential  
1.0 Introduction  
Bt8960  
1.2 Contents of this Manual  
Software Users Guide  
1.2 Contents of this Manual  
Chapter  
Contents  
Overview  
Overview of the software design principles, portability considerations, hardware-related issues,  
application interface principles, and application code integration constraints.  
Software Structure  
Software Operation  
Description of the code structure, main routines, file names, and reserved names.  
Software operation principles, including the application interface and activation code sections.  
Compiling the Source  
Code  
Explains how to modify and compile the C source code to match the application hardware/software  
environment.  
Software Integration  
User Interface  
Explains how to integrate the application software with the Bt8960 software.  
Details of the User Interface operation, command structure, and status responses.  
How to use the Bt8960 software and user interface in an HDSL transceiver application.  
Lists control and status request commands, including opcodes, parameter values, etc.  
Software Application  
Command Set  
Reference  
1-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
2
2.0 Overview  
2.1 Software Structure and Operation  
The Bt8960 software is responsible for handling and monitoring the activation and normal  
operation activities of up to six Bt8960 HDSL bit-pumps.  
The Bt8960 software includes the following five major functional blocks:  
1. ApplicationContains the application specific code to initialize the system and to control  
any system level tasks.  
2. BtMainActivates the bit-pump control process for each of the Bt8960 chips present in the  
system. It also calls routines that handle messages received on the serial communication  
channel.  
3. Bt8960 ControlThe principal bit-pump control routine. The Control routine goes through  
a series of states that implement the various activation and normal operation activities.  
Every call to the Control routine executes the operations relating to a specific state, and the  
state variable is advanced to the next state. The same routine is used for all active bit-pump  
chips, only the state variable being bit-pump specific.  
4. User InterfaceReceives and executes user commands, and sending back status  
information. The interface is implemented either at the code level, called the  
Application-Program Interface (API) (when an application is integrated with the Bt8960  
software) or via a serial communication protocol. In both control options, the interface is  
based on a set of commands issued and parameter status returned.  
5. Interrupt HandlerThis routine is entered every time one of the Bt8960 chips initiates an  
interrupt. Most interrupts are handled by setting appropriate software flags.  
100251B  
Conexant  
2-1  
Preliminary Information/Conexant Proprietary and Confidential  
2.0 Overview  
Bt8960  
2.2 Portability  
Software Users Guide  
2.2 Portability  
The Bt8960 software is designed with code portability as a major goal. This approach creates a C  
code that can be easily modified to match different hardware and software environments.  
The code itself has hardware-related parameters which must be defined. For example, the  
absolute address space allocated to each of the Bt8960 chips depends on the specific hardware  
design and address decoding details.  
Another example of a hardware/software-dependent code section is the definition of the Bt8960  
interrupt handling routine. The routine itself is part of the supplied software (and should not be  
modified) but the routine header definition and notation is both processor and compiler dependent.  
These examples demonstrate the kind of modifications required in the source code in order to  
successfully compile and run the Bt8960 software.  
The Compiling the Source Codechapter describes all of the required modifications. In  
addition, these modifications are clearly marked and commented in the source files.  
2.3 Integration with Application-Specific Software  
The Bt8960 software controls and sequences all the activation operations which include real time  
operations. In a system where the Bt8960 software shares processing resources with the users  
application software, care must be taken to not impair bit-pump performance. Guidelines to handle  
real-time operations within applications are described and explained in detail in the Software  
Integrationchapter of this manual.  
2-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
2.0 Overview  
Software Users Guide  
2.4 Software Interfacing with the Bt8960  
2.4 Software Interfacing with the Bt8960  
Since all bit-pump operations (activation, performance monitoring, etc.) are handled by the Bt8960  
software, all user interaction with the bit-pumps is done through the Bt8960 software and not by  
directly accessing the Bt8960 chip. In some cases, performing a read/write operation can impair the  
proper operation of the control software.  
The Bt8960 software contains a User Interface (UI) module that allows full control over the  
operation of the bit-pumps and performance monitoring. The UI is based on a set of issued  
commands, and the Bt8960 software responds by performing the required action or supplying the  
required status. When used in the single processor configuration, it is highly recommended that the  
API and UI be used to ensure easy integration with code updates.  
There are two configurations for transferring commands and parameter status between an  
application and the Bt8960 software. In a single processor design, the interface is done using two  
API (Application-Program Interface) routines that are part of the Bt8960 software. The application  
issues commands and receives status by calling these routines.  
In a dual processor design, the Bt8960 bit-pumps are controlled by an 8032 processor and the  
application interfaces to the bit-pumps through the serial communication (UART) channel. In this  
configuration, the commands and status are sent as messages over the serial channel.  
Both configurations use exactly the same set of commands. This command set is designed for  
maximum flexibility in operating the bit-pumps, and supplies all the necessary performance and  
status monitoring information. Each bit-pump can be controlled and monitored individually via the  
UI.  
The User Interfacechapter describes the structure of the commands and the communication  
protocol for both UI configurations in detail. Appendix A is a reference guide to the set of  
commands and status bits, with details on command use, syntax, and operation.  
100251B  
Conexant  
2-3  
Preliminary Information/Conexant Proprietary and Confidential  
2.0 Overview  
Bt8960  
2.4 Software Interfacing with the Bt8960  
Software Users Guide  
2-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
3
3.0 Software Application  
Interaction with the Bt8960 bit-pumps is done by using the set of control and status request  
commands. This chapter addresses the issue of applying these commands in a complete HDSL  
transceiver system.  
3.1 System Configuration  
Before any other command or status request may be issued to a bit-pump, the system configuration  
needs to be defined, using the Bit-pump ON/OFF command. This informs the Bt8960 software  
which bit-pump is ON. Following power up, all bit-pumps are declared to be OFF. All commands  
(other than system configuration) sent to a bit-pump that is turned OFF are ignored by the Bt8960  
software.  
Turning ON a bit-pump means that the corresponding Bt8960 is installed in the system and is  
intended to be used. Not all Bt8960s that are installed in the system must be turned ON. A bit-pump  
may be turned ON or OFF at any time, and any combination of bit-pumps turned ON or OFF is  
allowed. Turning a bit-pump ON (even if it is turned ON already) resets the corresponding Bt8960,  
and all configured parameters must be reprogrammed.  
100251B  
Conexant  
3-1  
Preliminary Information/Conexant Proprietary and Confidential  
3.0 Software Application  
Bt8960  
3.2 Setting Bit-Pump Parameters  
Software Users Guide  
3.2 Setting Bit-Pump Parameters  
For proper operation of the bit-pumps, all configuration and operation parameters must be set to  
their correct values (depending on the specific application) prior to activating the bit-pumps. These  
parameters include design-specific information (such as analog AGC configuration, data transfer  
format, activation sequence source, etc.) and application specific parameters (such as symbol rate,  
terminal type, etc.).  
All parameters and configuration options have default values (see Appendix A). Only those  
parameters that have values different than the default need to be programmed. Table 3-1 lists all the  
user-programmable parameters together with their default values. See the User Interfacechapter  
and Appendix A for details regarding the use and syntax of the specific commands used to set these  
parameters.  
NOTE: The _SYM_RATE command must be immediately issued after the  
_SYSTEM_CONFIG ON command.  
Table 3-1. User Configurable Parameters and their Default Values  
Parameter  
Default  
Bit-pump On/Off  
Off  
Terminal Type  
HTU-C  
Other Side Bt8960  
Analog AGC Configuration  
Symbol Rate  
Non-Bt8960  
No AGC  
144 K Symbol/Sec  
1sec  
LOST Time Period  
Data Transfer Format  
Start-up Sequence Source  
Serial  
External  
Bypass  
Transmitter Scrambler On / Bypass  
Receiver Descrambler On / Bypass  
Operate Non Linear EC  
Bypass  
Off  
Transmitter Gain  
Calibration Value  
3-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
3.0 Software Application  
Software Users Guide  
3.3 Activation  
3.3 Activation  
Upon power-up, the bit-pumps move to an IDLE state where no activities take place. No signal is  
transmitted and the bit-pumps will not respond in any way to input signal detection. To initiate a  
activation procedure, an Activate command should be issued at the HTU-C and HTU-R terminals.  
This results in the transmission of a 2-level activation sequence, and begins the sequence of  
activation activities on the HTU-C.  
Under normal operating conditions, the HTU-R should detect the incoming signal and respond  
according to the standard activation protocol. The HTU-R bit-pump will respond in this way only if  
an Activate command was issued on the HTU-R terminal. Note that the Activate command on the  
HTU-R does not initiate a response, but enables such a response once a signal is detected.  
The order in which the Activate commands are issued at the HTU-C and HTU-R terminals is of  
no importance, but the complete activation procedure will take place only when both terminals are  
activated. When the HTU-C is activated first, it starts a 2-level transmission, but will get no  
response from the HTU-R until the HTU-R has been activated. It will therefore wait until an HTU-R  
signal is detected, and then proceed with the activation. When the HTU-R is activated first, it will  
wait for the detection of an HTU-C signal. Once the HTU-C has been activated it starts transmitting,  
and the HTU-R, upon detecting this transmission, will proceed with the activation.  
Once both terminals are activated, the complete sequence of activation activities is carried out  
on both terminals according to the standard protocol. No user intervention is required during this  
process.  
100251B  
Conexant  
3-3  
Preliminary Information/Conexant Proprietary and Confidential  
3.0 Software Application  
Bt8960  
3.3 Activation  
Software Users Guide  
It is the responsibility of the application software to monitor the appropriate status responses, in  
addition to Channel Unit frame sync status, during activation, and decide whether or not the  
activation has been successfully completed. The important status parameters for activation  
monitoring include noise margin, loss of signal (LOS, LOST), transmit 4-Level indicator, and  
activation timers expiration. Table 3-2 describes these together with the specific status request  
commands that are used to access each status parameter. Table 3-3 shows additional bit-pump  
responses that do not relate directly to the activation procedure. Further information may be found  
in the User Interfacechapter and in Appendix A.  
Table 3-2. Start-up Status Parameters  
Command  
Name  
Indication  
Description  
Noise Margin  
An estimate of the noise margin (in dB), indicating the tolerable increase in noise level  
while still maintaining a BER<1E–7.  
Noise Margin  
Noise Margin OK  
LOS  
1 indicates noise margin higher than –5 dB.  
Bit-pump Status  
Bit-Pump Status  
0 Indicates the presence of an incoming signal, 1 indicates no input signal present.  
Status is based on average far-end signal power measurement. This status is valid at all  
times.  
LOST  
1 indicates the presence of a LOS condition for more than the LOST time period  
Bit-Pump Status  
(programmable). The LOST response is valid only after a Deactivate command is issued.  
Activation Timer  
Transmit 4-Level  
1 indicates expiration of the activation interval.  
Bit-Pump Status  
Bit-Pump Status  
Bit-Pump Status  
1 indicates the bitpump is transmitting a 4-Level signal.  
Normal Operation 1 indicates the bitpump has completed the stages of the activation process.  
Table 3-3. Additional Status Parameters  
Indication  
Description  
Command Name  
Input Signal Level  
Total Input Signal Level  
Average absolute level of signal at the input to the A/D. This  
signal is composed of both the far-end and echo signals.  
Input DC Offset  
Average DC offset at the input to the A/D. A high value may  
cause performance degradation.  
Input DC Offset  
Cable Attenuation  
Total signal attenuation (in dB).  
Far-end Signal Attenuation  
VCXO Control Voltage  
Frequency Deviation  
Value of the (digital) VCXO control signal.  
3-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
3.0 Software Application  
Software Users Guide  
3.4 Test Modes  
3.4 Test Modes  
The Bt8960 may be operated in special test modes, used during development and field operation,  
for maintenance and fault identification. All test modes are activated using the Test Mode  
command, with the command parameter value selecting the specific mode.  
To exit a test mode, issue the Test Mode command with the _EXIT_TEST_MODE (0x00 value)  
parameter. The action taken when exiting a test mode condition depends on the specific test mode  
selected. Activating most test modes while the bit-pump is synchronized will cause the bit-pump to  
lose sync. Exiting the test mode and going back to normal data transfer condition will require full  
restart. In these cases, the bit-pump goes to the IDLE state when exiting the test mode.  
Other test modes do not create a sync loss condition, and normal operation may continue when  
exiting the test condition. When exiting one of these test modes, the bit-pump goes back to the state  
that was active when the Test Mode command was issued.  
Table 3-4 describes the available test modes, and shows for each mode the ability to go back to  
normal operation. Further information may be found in the User Interface section and in  
Appendix A.  
Table 3-4. Bt8960 Test Modes (1 of 2)  
Sync  
Loss  
Test Mode  
Description  
External Analog loopback  
Transmits the externally supplied TX symbols, use the echo signal as a  
receivedsignal, and detect the symbols using the standard equalizer.  
Digital nearloopback  
Digital farloopback  
TX symbols supplied to the bit-pump (by the framer) are looped back as the  
RX symbols going from the bit-pump to the framer. Useful for testing the  
framer and the framer-bit-pump connection.  
Detected (RX) symbols are transmitted back on the loop. Useful for testing full  
2-way transmission over a loop.  
Note: the operation of a digital farloopback requires activating the  
Bt8960 internal TX scrambler and RX descrambler.  
Transmit isolated +3 pulse  
Transmits (repeatedly) an isolated +3 level pulse. Useful for testing the  
transmitted pulse shape.  
Transmit isolated +1 pulse  
Transmit isolated 1 pulse  
Transmit isolated 3 pulse  
Continuous 4-level transmission  
Transmits (repeatedly) an isolated +1 level pulse.  
Transmits (repeatedly) an isolated 1 level pulse.  
Transmits (repeatedly) an isolated 3 level pulse.  
Continuous transmission of a 4-level scrambled 1's sequence (internally  
generated). Useful for measuring transmitted power and spectral shape.  
Continuous 2-level  
transmission  
Continuous transmission of a 2-level scrambled 1s sequence (internally  
generated).  
Set minimum VCXO  
frequency  
Sets VCXO control word to its minimum value.  
Set nominal VCXO frequency  
Sets VCXO control word to its nominal value. Useful for measuring VCXO  
center frequency.  
100251B  
Conexant  
3-5  
Preliminary Information/Conexant Proprietary and Confidential  
3.0 Software Application  
Bt8960  
3.4 Test Modes  
Software Users Guide  
Table 3-4. Bt8960 Test Modes (2 of 2)  
Sync  
Loss  
Test Mode  
Description  
Sets VCXO control word to its maximum value.  
Set maximum VCXO  
frequency  
Internal Analog loopback  
Transmits the externally supplied Tx symbols out the TXP and TXN pins and  
detects the symbols on the hybrid inputs (RXBP, RXBN), the receive inputs  
(RXP and RXN) are bypassed.  
Isolated Analog loopback  
The externally supplied Tx symbols are internally looped back in the Bt8960.  
The transmitter (TXP and TXN) is turned off (silent).  
Table 3-5 shows the relationship between the Chip Revision, Software Version, and Analog Loopbacks  
supported.  
Table 3-5. Analog Loopback vs. Version Relationships  
Version  
V 1.x  
External  
None  
Internal  
None  
Isolated  
None  
V 2.0+  
Rev. B and C  
Rev C only  
Rev C only  
3-6  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
3.0 Software Application  
Software Users Guide  
3.5 Internal BER Meter Operation  
3.5 Internal BER Meter Operation  
This section describes how to use the Bt8960s Internal BER Meter. The BER meter code is only  
accessible when the BER_METER compiler flag is declared. The BER Meter can be used to verify  
the integrity of the line, and as a diagnostic tool during production/field testing or  
hardware/software development.  
The BER Meter uses its internal scrambled ones generator and de-scrambler to detect  
bit-errors. For the BER Meter to function properly, both the HTU-C and HTU-R must issue the  
_BER_METER_START API command. Since the BER Meter uses its own internal scrambled ones  
generator, it cannot be used when transporting real payload data. The BER Meter is only  
operational after the bit-pump has successfully completed startup. All access to the BER meter is  
done through the API, see Appendix A.  
The interrupt handler reads the Bit Error Rate Meter Register (Address 0x4C, 0x4D) and  
updates the Number of Bit-Errors and Number of Meter Intervals counter after every meter interval.  
This causes the interrupt handler to be slightly longer, ~55uS per bit-pump on an 11.0592MHz  
Intel 8032.  
3.5.1 Calculating Avg BER and Elapsed Time  
The following formulas are used to calculate the Avg BER and Elapsed Time.  
#ofBitError s  
AvgBER  
=
#ofMeterInt ervals *MeterInter valLength *2  
= #ofMeterInt ervals *MeterInter valLength *2  
DataRate  
ElapsedTim e  
Variable  
# of Bit-Errors  
How Derived  
Read the # of Bit-Errors Low & High Byte API commands and build a 16-bit unsigned integer.  
Read the # of Meter Intervals Low & High Byte API commands and build a 16-bit unsigned integer.  
# of Meter Intervals  
Meter Interval Length  
Read the Bt8960 Meter Interval Register (Address 0x18, 0x19) and build a 16-bit unsigned integer.  
During normal operation, these registers should always read 0x8000 (32768).  
Data Rate  
2
Data Rate of the system, i.e. 288000 or 416000.  
The * 2is necessary because there are 2 bits per symbol and the meter interval length is based on the  
number of symbols.  
NOTE(S): 16-bit value = (high byte << 8) + (low byte)  
100251B  
Conexant  
3-7  
Preliminary Information/Conexant Proprietary and Confidential  
3.0 Software Application  
Bt8960  
3.5 Internal BER Meter Operation  
Software Users Guide  
Figure 3-1. Example  
/*  
* Assuming 288kbps Data Rate, Normal Operation, and BER Meter Active  
* Also assumes using compiler/linker that supports floating point.  
*/  
void get_ber_meter_status (unsigned char no)  
{
unsigned char temp, temp1;  
unsigned int errors, intervals;  
float avg_ber, elapsed_time;  
_BtStatus(no, _BER_METER_STATUS, _BER_BIT_ERRORS_LOW, &temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_BIT_ERRORS_HIGH, &temp1);  
errors = (unsigned)BYTE2WORD(temp1, temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_METER_INTERVALS_LOW, &temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_METER_INTERVALS_HIGH, &temp1)  
intervals = (unsigned)BYTE2WORD(temp1, temp);  
avg_ber = (errors) / (intervals * 0x8000 * 2) /* equations don’t show necessary type casting */  
elapsed_time = (intervals * 0x8000 * 2) / (288000)  
#if TDEBUG  
printf("# Bit Errors = %u\n", errors);  
printf("# Meter Intervals = %u\n", intervals);  
printf("Avg Ber = %.2e\n", avg_ber);  
printf("Elapsed Time = %.1f seconds\n", elapsed_time);  
#endif  
return;  
}
3-8  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
4
4.0 Software Structure  
This chapter describes the structure of the Bt8960 control software. The information is useful for  
understanding the Bt8960 operation and the proper integration of Bt8960 code with the application  
software.  
4.1 Software Block Diagram  
This section describes the major Bt8960 software logical blocks and briefly outlines their function.  
Figure 4-1 shows the major software modules and their relation with application specific software.  
Figure 4-1. Bt8960 Software Modules  
Application-Specific Software  
Serial  
Comm.  
HTU-C  
API  
BtMain  
Activation  
Interrupt  
Handler  
HTU-R  
Activation  
User Set  
Parameters  
Indications  
Utility  
Routines  
Test  
Modes  
Bt8960  
Control  
User Interface  
100251_001  
100251B  
Conexant  
4-1  
Preliminary Information/Conexant Proprietary and Confidential  
4.0 Software Structure  
Bt8960  
4.1 Software Block Diagram  
Software Users Guide  
The Application block contains the applications high level system tasks, i.e. activation state  
diagram, diagnostics, controlling other devices, etc. The _BtMain() module is called by the  
applications main program, and it is important to ensure a periodic execution of this module within  
specified real-time constraints (see the Software Integrationchapter for details).  
The _BtMain() module is responsible for executing all the specific Bt8960 tasks, including the  
bit-pump control operations, and the received/transmitted message handling. This is the highest  
level block in the Bt8960 software hierarchy, and should be executed repeatedly and indefinitely to  
ensure proper operation of the bit-pumps.  
The Bt8960 Control block contains the bit-pump activation control routines (for the central  
office and remote terminals) and special test mode routines. The activation control routine is  
executed periodically for every active Bt8960 chip. It goes through the complete activation  
procedure and handles normal operation monitoring activities. The test modes module is  
responsible for operating the bit-pump in a specified test mode, such as loopback, isolated pulse  
transmission, etc.  
The User Interface block implements all the tasks related to communication with an  
application. This communication is either done through a serial communication protocol or by using  
code level API routines. The UI block interprets received commands, performs the required  
operation, and sends back status reports.  
The Interrupt Handler block responds to Bt8960 interrupts, sets the software interrupt flags,  
and in special cases, performs bit-pump operations that cannot be delayed.  
4-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
4.0 Software Structure  
Software Users Guide  
4.2 User-Called Routines  
4.2 User-Called Routines  
The routines found in Table 4-1 must be called or accessed by the application software. Further  
details regarding these specific routines are given in the User Interfaceand the Software  
Applicationchapters and Appendix A. Further information and documentation may be found in  
the source files.  
Table 4-1. Bt8960 Software Routines  
Routine / Macro  
File Name  
Description  
_BtSwPowerUp()  
btmain.c  
Bt8960 software initialization. Must be executed prior to any other Bt8960 related  
operation.  
_MaskBtHomerInt()  
_Init8051()  
btmain.c  
init51.c  
intbug.c  
api.c  
Masks all Bt8960 interrupts for all present Bt8960 chips.  
Used only in 8032 environment. Initializes 8032-specific parameters.  
Used only with the INT_BUG compiler flag. Initializes Virtual Timers.  
API routine. Called by the application to issue a control command.  
_InitVirtualTimers()  
_BtControl()  
_BtStatus()  
api.c  
API routine. Called by the application to issue a status request command and to get  
the requested status.  
_BtMain()  
btmain.c  
Main Bt8960 control routine. Calls all Bt8960 tasks. Should be executed repeatedly  
and indefinitely.  
100251B  
Conexant  
4-3  
Preliminary Information/Conexant Proprietary and Confidential  
4.0 Software Structure  
Bt8960  
4.3 Memory Requirements  
Software Users Guide  
4.3 Memory Requirements  
The code ROM requirements depend on the compiler, processor in use, and compiler flags. The  
RAM and ROM requirements for four common build options with their associated compiler flags  
are shown in Table 4-2.  
4.3.0.1 BT8960CR w/o BER_METER  
C51,ADD_DELAY,PDATA_MODE,SER_COM,HTUC,HTUR,SINGLE_LOOP,CHAN_UNIT  
4.3.0.2 BT8960CR w/ BER_METER  
C51,ADD_DELAY,PDATA_MODE,SER_COM,HTUC,HTUR,SINGLE_LOOP,BER_METER,  
CHAN_UNIT  
4.3.0.3 BT8960C w/ BER_METER  
C51,ADD_DELAY,PDATA_MODE,SER_COM,HTUC,SINGLE_LOOP,BER_METER,  
CHAN_UNIT  
4.3.0.4 BT8960R w/ BER_METER  
C51,ADD_DELAY,PDATA_MODE,SER_COM,HTUR,SINGLE_LOOP,BER_METER,CHAN_  
UNIT  
Table 4-2. Memory Requirements  
Build Option  
RAM  
111  
117  
117  
117  
ROM  
24.0 k  
24.4 k  
20.0 k  
20.6 k  
BT8960CR w/o BER_METER  
BT8960CR w/ BER_METER  
BT8960C w/ BER_METER  
BT8960R w/ BER_METER  
The RAM requirements do not include the stack size, an additional 24 bytes is required for the run-time  
stack. These requirements include the Activation State Diagram application example code.  
4-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
5
5.0 Compiling the Source Code  
This chapter contains detailed information on how to successfully modify and compile the source  
code to match the specific application environment. The code modifications are required in order to  
match the Bt8960 code to the processor/compiler environment and to the details of the system  
hardware implementation.  
In addition to the source code modifications, compilation directives must be correctly declared  
at compile time.  
To get a fully working executable code, perform the following steps:  
1. Determine the correct compiler directives definitions suitable for the environment (see the  
Compilation Directives section).  
2. Modify or write all the application modifiable sections by following the instructions in this  
chapter.  
3. Compile and link all the source files. Use the file list and dependency information given in  
the File Names and Dependencies section.  
NOTE: If the C51 flag is declared (indicating an 8032 family processor and Keil & Franklin  
C51 compiler), modify or write only specific application sections (see the Code  
Modifications section).  
5.1 Directory Structure  
The directory structure is partitioned into two directories. The main (application specific) directory  
as the root and the bit-pump code as a sub-directory labeled BITPUMP. The application examples,  
hex files, build script files, etc. are found in the main directory. All of the bit-pump source code and  
header files are found in the BITPUMP subdirectory. However, the final implementation of the  
directory and file structure is up to the user.  
100251B  
Conexant  
5-1  
Preliminary Information/Conexant Proprietary and Confidential  
5.0 Compiling the Source Code  
Bt8960  
5.2 File Names and Dependencies  
Software Users Guide  
5.2 File Names and Dependencies  
Table 5-1 lists all the files that should be compiled and linked in order to get a complete, executable  
Bt8960 control code. The table also shows the dependency between the various files.  
Table 5-1. Source File Names and Dependencies  
File to be Compiled  
api.c  
File Depends on...  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bthomer.h  
bitpump.c  
btint.c  
btmain.c  
init51.c  
intbug.c  
mail.c  
main.c  
serint.c  
suc.c  
sur.c  
suutil.c  
testmode.c  
user.c  
util.c  
erle.c  
Other Files  
File Depends on...  
bthomer.h  
btmain.h, mail.h, init51.h,  
intbug.h, serint.h, bitpump.h, suc.h,  
sur.h, suutil.h, util.h, api.h, testmode.h,  
user.h, ptrdef.h, reg51.h, erle.h  
5-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
5.0 Compiling the Source Code  
Software Users Guide  
5.2 File Names and Dependencies  
5.2.1 Compilation Directives  
The compilation directives select different code sections for compilation, and are used in code  
sections that are either hardware dependent or compiler dependent. Accurate declaration of these  
directives is necessary to generate a correctly working executable code.  
NOTE: It is extremely important that after declaring these directives, all of the source modules  
be recompiled to ensure the changes propagate throughout the entire executable.  
Failure to do so will result in unpredictable behavior.  
5.2.1.1 #SINGLE_LOOP; #TWO_LOOPS; #THREE_LOOPS; #FOUR_LOOPS; #SIX_LOOPS  
These compiler flags allow the developer to specify the maximum number of loops supported in  
their system. One and only one of these flags must be defined at a time. The bit-pumps are allocated  
in a sequential order starting with _BIT_PUMP0 (1st bit-pump) and ending with _BIT_PUMP5  
(6th bit-pump)  
Only the bit-pumps that are supported by the specified compiler flag may be accessed during  
run-time, otherwise unpredictable behavior will result. For example, if THREE_LOOPS is defined,  
then only _BIT_PUMP0, _BIT_PUMP1, and _BIT_PUMP2 may be addressed.  
Each subsequent loop adds ~8 bytes of ROM space and ~4 bytes of RAM.  
5.2.1.2 #C51  
The C51 flag should be declared when the Bt8960 software is executed on an Intel 8032 family  
microprocessor and the Keil/Franklin C compiler is used to compile the source code.  
If another Intel 8032 family compiler is used, the C51 compiler flag may be defined. The user  
must be aware there may be compatibility issues between the compilers.  
If any non Intel 8032 family microprocessor and C compiler are used, do not declare the C51  
flag.  
5.2.1.3 #PDATA_MODE, #XDATA_MODE  
The PDATA_MODE and XDATA_MODE flags can only be declared together with the C51 flag.  
The PDATA_MODE and XDATA_MODE flags set the addressing mode used to access the Bt8960  
chips. One and only one of these flags must be declared in a C51 system.  
The PDATA_MODE flag selects page mode addressing which results in reduced ROM  
requirements for code space and faster execution. The XDATA_MODE flag selects external  
non-paged addressing. This results in greater code size and ROM requirements, and somewhat  
slower execution of the control code.  
For PDATA_MODE, in each of the bit-pump functions, the P2 port is set to address the  
specified bit-pump. In addition, the bit-pump interrupt saves the P2 port value before addressing the  
bit-pumps, then restores the previous P2 port value on exit of the interrupt function. Special care  
must be taken so that the P2 port value does not get erroneously modified by any other interrupt  
handler or another section of code.  
NOTE: If the Franklin & Keil Compilers Large memory model is defined, the  
XDATA_MODE compiler flag should be set since all variables are declared in xdata  
space.  
100251B  
Conexant  
5-3  
Preliminary Information/Conexant Proprietary and Confidential  
5.0 Compiling the Source Code  
Bt8960  
5.2 File Names and Dependencies  
Software Users Guide  
5.2.1.4 #SER_COM  
The SER_COM flag enables the serial communication protocol of the user interface. It is used in the  
dual processor mode of operation. It should be declared in an 8032-based system that employs the  
serial communication configuration for controlling the Bt8960. The SER_COM flag may be  
declared only if the C51 flag is declared.  
5.2.1.5 #ADD_DELAY  
Defining the ADD_DELAY flag causes the addition of a 2-symbol delay before accessing specific  
addresses in the Bt8960. This additional delay is required when a read/write operation to the Bt8960  
is performed in less than a symbol time period. The delay is added only for very specific Bt8960  
addresses where the read/write operations are limited to one access per symbol. The ADD_DELAY  
flag should be declared only when the external read/write cycle time of the microprocessor is faster  
than the symbol rate.  
5.2.1.6 #HTUR; #HTUC  
The HTUR and HTUC flags control whether HTU-R or HTU-C code is included in the executable.  
For applications where there is no distinction between HTU-R and HTU-C, except at the time of  
installation, having a single piece of code that serves as HTU-R and HTU-C is useful. For these  
applications both HTUR and HTUC should be declared.  
If code space is a constraint, the HTU-R and HTU-C code can be customized for each terminal  
type. Since the control process for each terminal type is in separate code, and represents a  
substantial portion of the code, it is possible to save ROM space by only declaring HTUR for the  
HTU-R terminal code and HTUC for the HTU-C terminal code. In this case the  
_TERMINAL_TYPE command would be fixed in code with its parameter set in accordance with  
the terminal type for which the code is being compiled.  
The HTUC code adds ~4 k of ROM and ~5 bytes of RAM.  
The HTUR code adds ~4.6 k of ROM.  
5.2.1.7 #CHAN_UNIT  
The CHAN_UNIT flag provides hooks into the Serial Communication Interface to allow the user to  
access user defined API commands. In the Brooktree EVM Systems, these API access the Channel  
Unit EVM boards (Channel Unit, Framer, & LIU). Please refer to the User Interface: Code Level  
Interface section for details.  
NOTE: The CHAN_UNIT flag may not be used when the #FOUR_LOOPS or #SIX_LOOPS  
flags are specified unless the User Defined API Commands section is modified.  
5.2.1.8 #BER_METER  
The BER_METER flag compiles in the BER Meter code. The BER Meter code adds ~400 bytes of  
ROM and 1 byte of RAM plus an additional 5 bytes of RAM for each bit-pump. Note that the  
BER_METER flag cannot be declared when the INT_BUG compiler flag is specified. See the  
Internal BER Meter section in the Software Application chapter.  
5.2.1.9 #ERLE  
The ERLE flag enables the ERLE diagnostic code. Please see Appendix C for details.  
5-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
5.0 Compiling the Source Code  
Software Users Guide  
5.2 File Names and Dependencies  
5.2.1.10 #INITIATED_INTERRUPT  
The INITIATED_INTERRUPT flag should not be declared. It provides minimal support for some  
multi-tasking operating systems. Multi-tasking operating system use with the activation code is not  
supported by Brooktree.  
5.2.1.11 #TDEBUG  
The TDEBUG flag should not be declared. TDEBUG provides printed text statements about the  
current status of the bit-pumps during activation. The messages are printed to the 8032s serial port.  
Because of this, TDEBUG cannot be used when SERCOM is declared. This flag can be useful for  
identifying problem areas in the activation sequence.  
5.2.1.12 #INT_BUG  
The INT_BUG flag should not be declared. The INT_BUG flag uses the microprocessors timer and  
RAM instead of the bit-pumps internal timers. This was needed in an earlier HDSL bit-pump  
product.  
5.2.2 Code Modifications  
The exact location of code sections to be modified are designated by comments of specific form in  
the source files. The format of these comments is shown in Figure 5-1.  
Figure 5-1. User-Modifiable Code Section Format  
/*---------------------------------------------------------*/  
/*>>>  
User Modifiable Section user.1 Begins  
<<< */  
/*---------------------------------------------------------*/  
/* Modification Description:  
/* Write the contents of routine EnableUserInterrupts().  
*/  
*/  
/* Calling this routine should enable all user interrupts. */  
/*  
*/  
*/  
*/  
/* Reference:  
/* “Bt8960 Software User's Manual”.  
/*---------------------------------------------------------*/  
Insert code here  
/*---------------------------------------------------------*/  
/*>>> User Modifiable Section user.1 Ends <<<*/  
/*---------------------------------------------------------*/  
These comments contain basic information describing the code section that should be modified  
(or written). All the modifications are referenced according to their source file name and the order  
in which they appear in the file. This reference (filename.X) appears both in source file  
comments and in this manual.  
100251B  
Conexant  
5-5  
Preliminary Information/Conexant Proprietary and Confidential  
5.0 Compiling the Source Code  
Bt8960  
5.2 File Names and Dependencies  
Software Users Guide  
Each of the following sections refers to a single code section which must be modified or  
written. All necessary modifications are covered, and no other changes in the source code should be  
made.  
The bit-pump source files that contain modifiable sections are btint.c, init51.c, serint.c, suc.h  
and user.c. No modifications should be made in any other file.  
5.2.2.1 Application Code  
The EVM Application Code contains templates (examples) for the main() routine of the application  
specific code. This main routine should execute both the application tasks and the Bt8960 software  
task. Please refer to the Bt8960 Single-Chip 2B1Q Transceiver EVM Software Manual for details.  
Extreme care must be taken to ensure that the application code (the body of the infinite loop)  
meets the real-time requirements outlined in the Software Integrationchapter. The concept is that  
the time period between successive activations of _BtMain() must be kept lower than a specified  
limit. This requirement puts constraints on the maximum execution time of the application code  
5.2.2.2 btint.c.1  
Code section btint.c.1 should contain the header of the Bt8960 interrupt handling routine. The body  
of the interrupt routine is already written, and should not be modified in any way. However, the  
routine header syntax is hardware, microprocessor, and compiler specific and must be written for  
the specific configuration.  
This routine should be invoked every time a Bt8960 interrupt signal is asserted (the Bt8960 INT  
pin is an active-low-level triggered signal). This interrupt should be enabled on power-up. It is  
necessary to ensure the interrupt vector is initialized within the application.  
When using the Borland C compiler, the interrupt routine header is defined as follows:  
void interrupt _HandleBtInterrupt(void)  
The application specific power-up initialization code should set the _HandleBtInterrupt()  
routine to function as the Bt8960 interrupt.  
5.2.2.3 init51.c  
Module init51.c contains the Intel 8032 microprocessor initialization routines.  
5.2.2.4 init51.c.1  
Code Section init51.c.1 should contain the baud rate timer initialization value. The initialization  
value is dependent on the microprocessor and the crystal frequency.  
5-6  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
5.0 Compiling the Source Code  
Software Users Guide  
5.2 File Names and Dependencies  
5.2.2.5 serint.c.1  
Code section serint.c.1 should contain the header of the serial interrupt handling routine. The body  
of the interrupt routine is already written. However, the routine header syntax and some variables  
are hardware, microprocessor, and compiler specific and must be written for the specific  
configuration.  
This routine should be invoked every time a serial interrupt signal is asserted. This interrupt  
should be enabled on power-up. It is necessary to ensure the interrupt vector is initialized within the  
application.  
When using the Borland C compiler, the interrupt routine header is defined as follows:  
void interrupt _HandleSerialInterrupt(void)  
The application specific power-up initialization code should set the _HandleSerialInterrupt()  
routine to function as the serial interrupt.  
5.2.2.6 suc.h.1  
Code Section suc.h.1 should contain the activation interval timer initialization value. The  
ACTIVATION_INTERVAL macro determines the time to complete the activation state diagram in  
seconds. The initialization value is dependent on the application symbol rate. This value should be  
modified so the activation does not prematurely time out during a successful attempt or does not  
take excessive time to time out during an unsuccessful attempt.  
The activation interval timer uses the SUT4 activation timer (symbol rate / 1024). The  
_SYM_RATE API command sets the symbol_ratevariable to symbol rate / 4096. Therefore, the  
value is 4 * desired activation time in seconds * the symbol_ratevariable.  
Example:  
For a desired activation interval timer of 50. The ACTIVATION_INTERVAL macro needs to be  
programmed to 4 * 50 * symbol_rate, or 4 * (32 + 16 + 2) * symbol_rate. The macro is implemented  
as follows:  
((((short) symbol_rate << 5) + ((short)symbol_rate << 4) + ((short)symbol_rate)<<1)) << 2)  
5.2.2.7 user.c.1  
Code section user.c.1 should contain the absolute I/O address definitions of the specified number of  
Bt8960 chips as defined by the compiler flags. Any value may be defined for non-existent Bt8960  
chips.  
The address value depends on the address decoding scheme implemented in the system. The  
defined address should reflect the value that accesses byte #0 on the Bt8960.  
5.2.2.8 user.c.2  
Code section user.c.2 should contain the noise margin calibration table. This table must be modified  
by the user to be accurate when using different noise source types. Refer to Appendix B for details.  
100251B  
Conexant  
5-7  
Preliminary Information/Conexant Proprietary and Confidential  
5.0 Compiling the Source Code  
Bt8960  
5.2 File Names and Dependencies  
Software Users Guide  
5.2.2.9 user.c.3  
Code section user.c.3 contains code that initializes the C pointers used to access the Bt8960 chips.  
The initialization of a pointer with an absolute external address value is done differently in some C  
compilers.  
The values of the array should be initialized as follows:  
_bit_pump[_BIT_PUMP0] should be initialized with the external address  
BIT_PUMP0_ADD.  
_bit_pump[_BIT_PUMP1] should be initialized with the external address  
BIT_PUMP1_ADD.  
_bit_pump[_BIT_PUMP2] should be initialized with the external address  
BIT_PUMP2_ADD.  
In an environment that allows direct assignment of absolute addresses to pointer variables, the  
user.c.3 code section should be written as follows:  
_bit_pump[_BIT_PUMP0] = BIT_PUMP0_ADD;  
_bit_pump[_BIT_PUMP1] = BIT_PUMP1_ADD;  
_bit_pump[_BIT_PUMP2] = BIT_PUMP2_ADD;  
When using the Borland C compiler, initializing pointer addresses with an absolute value is  
done using a special C macro in the following way:  
_bit_pump[_BIT_PUMP0] = MK_FP(BIT_PUMP_SEGMENT,  
BIT_PUMP0_ADD);  
_bit_pump[_BIT_PUMP1] = MK_FP(BIT_PUMP_SEGMENT,  
BIT_PUMP1_ADD);  
_bit_pump[_BIT_PUMP2] = MK_FP(BIT_PUMP_SEGMENT,  
BIT_PUMP2_ADD);  
This assumes all bit-pumps use the same segment, defined by BIT_PUMP_SEGMENT, and the  
bit-pump address constants define the address offset of each bit-pump.  
5.2.2.10 user.c.4  
The contents of _Delay2Symbols() routine are application specific. This routine should implement  
a delay of 2 symbol periods.  
NOTE: Depending on the microprocessor and compiler, entering and exiting this routine may  
generate the required delay with no need for additional operations or NOPs.  
5.2.2.11 user.c.5  
The code section user.c.5 contains the body of the routine _EnableUserInterrupts(), and is  
application specific. This routine, when executed, enables all the non-Bt8960 interrupts that are  
disabled by _DisableUserInterrupts() (see user.c.6). The Bt8960 interrupt is never disabled, so there  
is no need to enable it. The two routines _DisableUserInterrupts() and _EnableUserInterrupts() are  
called by the Bt8960 software in critical activation phases.  
5-8  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
5.0 Compiling the Source Code  
Software Users Guide  
5.2 File Names and Dependencies  
5.2.2.12 user.c.6  
The code section user.c.6 contains the body of the routine _DisableUserInterrupts(), and is  
application specific. The Activation sequence can tolerate 4 mS out of 6 mS of interrupts before  
performance degradation is noticed. This routine, when executed, should disable all the non-Bt8960  
interrupts that cause this time criteria to fail. The Bt8960 interrupt is always enabled. The  
_DisableUserInterrupts() and _EnableUserInterrupts() routines are called by the Bt8960 software  
in critical activation phases.  
5.2.2.13 api.c.1  
5.2.2.14 api.c.2  
5.2.2.15 api.c.3  
5.2.2.16 api.h.1  
In the API.C and API.H, the Channel Unit API hooks (found within the CHAN_UNIT compiler  
flags) can be modified to allow the user to define their own API commands. Please refer to the User  
Interface: Code Level Interface section for details.  
100251B  
Conexant  
5-9  
Preliminary Information/Conexant Proprietary and Confidential  
5.0 Compiling the Source Code  
Bt8960  
5.2 File Names and Dependencies  
Software Users Guide  
5-10  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
6
6.0 User Interface  
This chapter describes the User Interface (UI) to the Bt8960 HDSL bit-pump software. This  
interface allows the system designer to have full control over all of Bt8960 features, and get status  
and performance monitoring information from the bit-pump.  
The interaction between the application and the Bt8960 may be achieved in one of two  
configurations, depending on whether the application software is implemented on the same  
microprocessor as the Bt8960 control software or on a different microprocessor. When only one  
microprocessor is used in a system, the application should interface the bit-pumps using a  
code-level Application-Program Interface (API). In a design in which the Bt8960 software runs on  
an 8032 microprocessor, and a second hostmicroprocessor is used for the application software, a  
serial communication protocol between the two processors is used to control the bit-pumps.  
Figure 6-1 and Figure 6-2 show the two possible control configurations.  
Figure 6-1. Two Microprocessors Implementation  
Brooktree Chip Set  
Application  
External Circuitry  
External Circuitry  
Data  
and  
Clock  
Data  
and  
Clock  
Bt8960  
1
Bt8960  
2
P Bus  
Non-modified  
Brooktree  
Software  
Application  
Implemented  
Software  
UART  
8032 Controller  
Host Processor  
100251_003  
100251B  
Conexant  
6-1  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
Software Users Guide  
Figure 6-2. Single Microprocessor Implementation  
Brooktree Chip Set  
External Circuitry  
External Circuitry  
Data  
and  
Clock  
Data  
and  
Clock  
Bt8960  
1
Bt8960  
2
P Bus  
API  
Modified  
Brooktree  
Software  
Application  
Software  
Host Processor  
100251_004  
In both configurations described above, the control and monitoring operations are based on a  
set of commands sent by the application to the bit-pump control software and parameter status sent  
back to the application. The command set itself is identical in both system configurations.  
The Command Structure section describes the structure of commands and status responses,  
which applies to both UI configurations. The Serial Communication Interface section describes the  
serial interface message structure and communication protocol which applies to a dual processor  
system architecture, and the Code Level Interface (API) section describes the API which applies to  
a single processor architecture. The Opcodes and Parameters section lists the available commands.  
Appendix A (Command Set Reference) supplies a detailed description of the command set  
including command syntax, operation, and application hints.  
6-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.1 Command Structure  
6.1 Command Structure  
The structure of all commands is the same. A command is composed of three 1-byte fields:  
Destination, Opcode, and Data. Figure 6-3 shows the structure of a command.  
Figure 6-3. Command Structure  
7
1
6
1
5
1
4
1
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
E3 E2  
E1 E0  
O7 O6 O5 O4 O3 O2 O1 O0  
D7 D6 D5 D4 D3 D2  
D1 D0  
First Byte  
Second Byte  
Third Byte  
100251_005  
The command fields are interpreted according to the following fields.  
Destination field (bits E3E0)This field selects the destination to which the command is  
targeted, according to Table 6-1.  
Table 6-1. Destination Field Specification  
E3  
0
E2  
0
E1  
0
E0  
0
Destination  
Bt8960 #0  
Bt8960 #1  
Bt8960 #2  
Bt8960 #3  
Bt8960 #4  
Bt8960 #5  
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
Opcode field (bits O7O0)The Opcode field selects the specific command or status  
request to be executed. The available commands and their opcodes are described in detail in  
Appendix A. The opcodes are also available in C source file api.h, which contains C  
constant definitions for all opcodes. The Opcodes and Parameters section contains a list of  
these opcode constants.  
Data (Parameter) field (bits D7D0)This field is used in some commands where  
additional data or parameter selection is required. In commands where there is no need for  
additional data, zeros should be placed as the data byte to ensure future compatibility. The  
data field options are also available in C source file api.h, which contains C constant  
definitions for the available parameters. The Opcodes and Parameterssection contains a  
list of these data field constants.  
100251B  
Conexant  
6-3  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.1 Command Structure  
Software Users Guide  
The set of commands is divided into three logical groups: control commands, status request  
commands, and special messages. The first group includes all commands that control the operation  
of the bit-pump and set different parameters. The second group includes commands that request  
status values or monitoring information from the bit-pump. In response to a status request  
command, a 1-byte data word is returned to the application supplying the required information. The  
special messages include the Acknowledge message (applies only to serial communication UI).  
6-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.2 Serial Communication Interface  
6.2 Serial Communication Interface  
In a dual processor system (see Figure 6-1), the application controls the bit-pumps using a serial  
communication message transfer protocol. The protocol is based on the command set described in  
Appendix A, and the command structure as described in the Command Structure section, with  
additional requirements for this type of interface.  
6.2.1 Communication Protocol  
The 8032 communicates with the host processor using a standard UART interface. The physical  
connection includes two lines: RXD (8032 pin 10) and TXD (8032 pin 11). The data is transferred  
in an asynchronous format: 9600 baud, 1 start bit, 8 data bits, 1 stop bit, no parity.  
To select a separate baud rate, refer to the Compiling the Source Codechapter.  
6.2.2 Message Transfer Protocol  
The application sends a command to any of the bit-pumps in the system by transmitting a message  
over the serial communication channel. Every command that is correctly received and decoded by  
the 8032 is acknowledged by sending a special acknowledge message back to the application. In  
response to a status request command, the 8032 also sends a status response message that contains  
the information requested.  
The 8032 is guaranteed to acknowledge a received message within 200 mS, except during  
activation where larger delays (up to 2 seconds) may be present. The host processor will usually  
retransmit a message that was not acknowledged within this time limit. No new message should be  
sent by the host processor before the previous one was acknowledged unless the time limit has been  
exceeded.  
A status request message requiring information from the bit-pump will first be acknowledged,  
and only then will a response message containing the requested information be sent to the host  
processor.  
100251B  
Conexant  
6-5  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.2 Serial Communication Interface  
Software Users Guide  
6.2.3 Message Structure  
All messages are 4 bytes long. Figure 6-4 shows the structure of a message sent by the host  
processor to the 8032. The first 3 bytes are the command bytes, as described in the Command  
Structure section. The fourth byte (the last transmitted byte) contains checksum information that is  
a function of the first 3 bytes (see the Checksum Function subsection for checksum function  
details). The checksum considerably reduces the probability of the 8032 misinterpreting an  
incoming message.  
When the 8032 receives a status request command, it responds (after acknowledging the  
command) by sending a status message to the host processor. The structure of a status message is  
similar to the structure of a host-to-8032 message, and is shown in Figure 6-5.  
The first 2 bytes are identical to the first 2 bytes of the corresponding status request command.  
Bits S3S0 of the first byte are interpreted, according to Table 6-1, as the source bit-pump for the  
status response. The second opcode byte (bits O7O0) contains the opcode of the command that  
requested the information.  
The third byte (bits D7D0) contains the requested information. The fourth byte (bits  
CS7CS0) is the checksum value, calculated according to the formula described in the Checksum  
Function subsection.  
Figure 6-4. Host Processor to 8032 Message Structure  
7
1
6
1
5
1
4
1
3
2
1
0
7
6
5
4
3
2
1
0
E3 E2 E1 E0  
O7 O6 O5 O4 O3 O2 O1 O0  
Second Byte  
First Byte  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
D7 D6 D5 D4 D3 D2 D1 D0  
Third Byte  
CS7 CS6CS5CS4CS3CS2CS1CS0  
Fourth Byte  
100251_006  
6-6  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.2 Serial Communication Interface  
Figure 6-5. 8032 to Host Processor Message Structure  
7
1
6
1
5
1
4
1
3
2
1
0
7
6
5
4
3
2
1
0
S3 S2 S1 S0  
O7 O6 O5 O4 O3 O2 O1 O0  
Second Byte  
First Byte  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
D7 D6 D5 D4 D3 D2 D1 D0  
Third Byte  
CS7CS6CS5CS4CS3CS2CS1CS0  
Fourth Byte  
100251_007  
6.2.4 Checksum Function  
For every command sent by the host processor, a checksum function value is calculated and sent as  
the fourth byte of the message. This value is calculated using the following formula:  
CS = (Byte #1) | (Byte #2) | (Byte #3) | (0xAA);  
where |denotes a bit-wise exclusive-OR operation, and 0xAA is the binary byte 10101010.  
The same rule is used by the 8032 to calculate the checksum byte of status message sent to the  
host processor.  
100251B  
Conexant  
6-7  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.3 Code Level Interface (API)  
Software Users Guide  
6.3 Code Level Interface (API)  
The code level API is intended for applications integrating the bit-pump control software in a single  
microprocessor system (see Figure 6-2). In such a configuration, the application issues a command  
and gets information from the bit-pumps by calling a specific routine.  
To issue any one of the control commands (see the Control Commands section in Appendix A),  
the application should call the _BtControl() function. To issue a status request command (see the  
Serial Communication Interface section), the _BtStatus() function should be called.  
6.3.1 _BtControl()  
The _BtControl() routine is used to issue any one of the control commands specified in the Control  
Commands section in Appendix A.  
Use  
unsigned char _BtControl(unsigned char destination, unsigned char opcode, unsigned char parameter);  
Description  
The destination, opcode, and data parameters correspond to the three command bytes as described in the  
Command Structure section. The opcode field must contain a value corresponding to one of the control  
commands specified in the Control Commands section in Appendix A  
Effect  
The required command is executed on the bit-pump designated by the destination parameter (unless an error  
condition occurred).  
Return Value  
_PASS (0x00) indicates a successfully interpreted command. The command is executed.  
_FAIL (0x01) indicates an error condition. The command is not executed. An error condition may be caused by  
an illegal value in any one of the command fields.  
Example  
To configure bit-pump #2 as a remote terminal (HTU-R), execute the following routine call:  
_BtControl(_BIT_PUMP2, _TERMINAL_TYPE, _HTUR);  
6-8  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.3 Code Level Interface (API)  
6.3.2 _BtStatus()  
The _BtStatus() routine is used to issue any one of the status request commands specified in the  
Status Request Commands section in Appendix A.  
Use  
unsigned char _BtStatus(unsigned char destination, unsigned char opcode, unsigned char parameter, char  
indication);  
Description  
The destination, opcode, and data parameters correspond to the three command bytes as described in the  
Command Structure section. The opcode field must contain a value corresponding to one of the status request  
commands specified in the Special Messages section in Appendix A.  
Effect  
The status parameter is set to the required value (unless an error condition occurred).  
Return Value  
Example  
_PASS (0x00) indicates a successfully interpreted command. The value of the status parameter is correctly set.  
_FAIL (0x01) indicates an error condition. The value of the status parameter has no meaning and should be  
ignored. An error condition may be caused by an illegal value in any of the command fields.  
6.3.3 User Defined API Commands - Channel Unit & Framer  
The code level API structure provides hooks to allow the user to access their own user defined API  
commands. In the dual processor mode, this allows the user to use the Serial Communication  
Interface message protocol to handle the user defined API commands. The user then only needs to  
create (define) their own API commands.  
The bit-pump code provides hooks to access the Channel Unit and Framer API commands,  
these are to support the Brooktree EVM Systems. However, the user may rename, add, or delete to  
these hooks.  
_CuControl()  
_CuStatus()  
_FramerControl()  
_FramerStatus()  
100251B  
Conexant  
6-9  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.3 Code Level Interface (API)  
Software Users Guide  
These function descriptions are identical to the _BtControl() and _BtStatus() functions. The  
Channel Unit EVM has the following Destination field values (see also Table 3):  
Table 6-2. Destination Field Values  
E3  
0
E2  
0
E1  
1
E0  
1
Destination  
Channel Unit Common Sections  
Channel Unit HDSLLoop #1 Specific  
Channel Unit HDSLLoop #2 Specific  
Channel Unit HDSLLoop #3 Specific  
E1/T1 Framer and LIU  
#define  
_CU_COMMON  
_CU_CHAN1  
_CU_CHAN2  
_CU_CHAN3  
_FRAMER  
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
The channel Unit and Framer destination fields are numbered 3 to 7 to maintain compatibility  
with existing Brooktree EVM System and Support Programs. However, these destination fields will  
cause a conflict when the #FOUR_LOOPS or #SIX_LOOPS complier flags are specified, since the  
#FOUR_LOOPS or #SIX_LLPS flags specify the destination field between (0 and 3) or (0 to 5). If  
the user wishes to use the #CHAN_UNIT compiler flag with the #FOUR_LOOPS or #SIX_LOOPS  
flags, then the Channel Unit destination fields must be modified.  
NOTE: The Brooktree EVMs are typically compiled with the #THREE_LOOPS and  
#CHAN_UNIT complier flags  
6-10  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.4 Opcodes and Parameters  
6.4 Opcodes and Parameters  
The source file api.h contains C constant definitions for the opcodes of all commands, and for the  
possible data field values of commands that use this field.  
NOTE: These definitions should be employed in application code for the Bt8960 UI.  
Table 6-3 lists the available commands, each with its corresponding C constant opcode and  
parameter definitions (where applicable). See Appendix A for details on command use, operation,  
and parameter setting.  
Table 6-3. User Interface Command Summary (1 of 3)  
Command Name  
Opcode C Constants  
Data Field Options  
HTU-R  
Data Field C Constants  
_HTUR  
Terminal Type  
_TERMINAL_TYPE  
HTU-C  
_HTUC  
Analog AGC  
_ANALOG_AGC_CONFIG  
No AGC  
_NO_AGC  
Configuration  
2-Level discrete AGC  
4-Level discrete AGC  
6-Level discrete AGC  
_TWO_LEVEL_AGC  
_FOUR_LEVEL_AGC  
_SIX_LEVEL_AGC  
Start-up Sequence  
Source  
_STARTUP_SEQ_  
SOURCE  
Internal start-up  
sequence  
External start-up  
sequence  
_INTERNAL  
_EXTERNAL  
Transmit Scrambler  
_TRANSMIT_SCR  
_RECEIVE_DESCR  
_FRAMER_FORMAT  
Scramble TX symbols  
Do not scramble TX  
symbols  
_ACTIVATE_SCR  
_BYPASS  
Receive  
Descrambler  
Descramble RX symbols  
Do not descramble RX  
symbols  
_ACTIVATE_DESCR  
_BYPASS  
Data Transfer  
Format  
Parallel data, clock  
outputs  
Parallel data, clock inputs  
Serial data  
_PARALLEL_MASTER  
_PARALLEL_SLAVE  
Serial data, sign &  
magnitude swapped  
_SERIAL  
_SERIAL_SWAP  
Other Side Bt8960  
_BT_OTHER_SIDE  
Bt8960 bit-pump used  
on other terminal  
_BT  
Non-Bt8960 bit-pump on  
other terminal  
_NO_BT  
LOST Time Period  
Bit-pump ON/OFF  
_LOST_TIME_PERIOD  
_SYSTEM_CONFIG  
1-Byte unsigned integer  
Bit-pump On  
Bit-pump OFF  
_PRESENT  
_NOT_PRESENT  
Transmit External  
Data  
_TRANSMIT_EXT_DATA  
0
Activate  
_ACTIVATE  
0
0
Deactivate  
_DEACTIVATE  
100251B  
Conexant  
6-11  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.4 Opcodes and Parameters  
Software Users Guide  
Table 6-3. User Interface Command Summary (2 of 3)  
Command Name  
Opcode C Constants  
_TEST_MODE  
Data Field Options  
Data Field C Constants  
_EXIT_TEST_MODE  
Test Mode  
_ANALOG_LOOPBACK  
_NEAR_LOOPBACK  
_FAR_LOOPBACK  
_ISOLATED_PULSE_PLUS3  
_ISOLATED_PULSE_PLUS1  
_ISOLATED_PULSE_MINUS1  
_ISOLATED_PULSE_MINUS3  
_FOUR_LEVEL_SCR  
_TWO_LEVEL_SCR  
_VCXO_NOMINAL  
_VCXO_MIN  
_VCXO_MAX  
_INTERNAL_ANALOG_  
LOOPBACK  
_EXTERNAL_ANALOG_  
LOOPBACK  
Symbol Rate  
Reset  
_SYM_RATE  
1-Byte unsigned integer  
0
_RESET_SYSTEM  
_OPERATE_NLEC  
Enable/Disable  
Non-Linear EC  
Enable NL EC  
Operation  
_NLEC_ON  
_NLEC_OFF  
Disable NL EC  
Operation  
Write Transmitter  
Gain register  
_WRITE_TX_GAIN  
1-Byte signed integer  
Input Signal Level  
Input DC Offset  
_SLM  
0
0
0
_DC_METER  
_FELM  
Far-end Signal  
Attenuation  
Noise Margin  
_NMR  
0
0
VCXO Control  
Voltage  
_VCXO_CONTROL_  
VOLTAGE  
Bit-pump Status  
_STARTUP_STATUS  
_AAGC_VALUE  
0
0
AAGC Control Bits  
Value  
Read Linear EC  
Coefficient  
_LEC_COEFF  
Coefficient index  
Coefficient index  
Read NL EC  
Coefficient  
_NLEC_COEFF  
Read EQ Coefficient  
_EQ_COEFF  
_DFE_COEFF  
Coefficient index  
Coefficient index  
Read DFE  
Coefficient  
6-12  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
6.0 User Interface  
Software Users Guide  
6.4 Opcodes and Parameters  
Table 6-3. User Interface Command Summary (3 of 3)  
Command Name  
Opcode C Constants  
_VERSION  
Data Field Options  
Data Field C Constants  
Software / Chip  
Versions  
Major SW & Bitpump  
Version  
_HW_SW_VERSIONS  
Major SW Version  
Minor SW Version  
Bitpump Type & Version  
_MAJOR_SW_VERSION  
_MINOR_SW_VERSION  
_HW_TYPE_VERSIONS  
Bit-pump Present  
Self-test  
_BIT_PUMP_PRESENT  
_SELF_TEST  
0
0
Read Bt8960  
Register  
_REGISTER  
Bt8960 register address  
Bit-pump  
Configuration  
_CONFIGURATION  
Request low byte of user  
setup  
Request high byte of  
user setup  
Request LOST time  
period information  
Request symbol rate  
information  
_USER_SETUP_LOW_BYTE  
_USER_SETUP_HIGH_BYTE  
_LOST  
_BIT_RATE  
Stage Number  
_STAGE_NUMBER  
_READ_TX_GAIN  
0
Read Transmitter  
Gain register  
Request Tx Calibration  
Value  
_CALIBRATION  
_GAIN  
Request Tx Gain Value  
100251B  
Conexant  
6-13  
Preliminary Information/Conexant Proprietary and Confidential  
6.0 User Interface  
Bt8960  
6.4 Opcodes and Parameters  
Software Users Guide  
6-14  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
A
Appendix A Command Set Reference  
This appendix contains a reference guide to the Bt8960 User Interface command set. All available  
commands are listed, giving information on command use, application, syntax, and options.  
The set of commands is divided into three groups:  
1. Control commandsControl the operation modes of the bit-pump and set various  
parameters.  
2. Status request commandsInquire for status and monitoring information from the  
bit-pump. A 1-byte response containing the required information is transferred back.  
3. Special Commands.  
A.1Control Commands  
For each command, a description of its operation, opcode, and options is given. Commands that  
select bit-pump operational options and set bit-pump parameters have their default value  
underlined. The default values are also given in the Setting Bit-pump Parameters section.  
A.1.1 Terminal Type  
Sets the bit-pump terminal type. In any operational HDSL system, a bit-pump on one side of the  
loop should be defined to be an HTU-C (HDSL Terminal Unit Central office side) and the  
bit-pump on the other side should be defined to be an HTU-R (Remote terminal). The two terminal  
types differ in their activation procedure, timing recovery mechanism, scrambler/descrambler taps,  
and more. Terminal type must be properly defined prior to any activation operation.  
100251B  
Conexant  
A-1  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
In a multipair system, each bit-pump may be individually set as an HTU-C or HTU-R  
(although in most implementations all bit-pumps will be set to the same terminal type).  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x01  
_TERMINAL_TYPE  
Options  
Option  
HTU-C  
HTU-R  
Description  
Central Office Terminal  
Remote Terminal  
Data Field  
0x00  
C Constant (api.h)  
_HTUC  
0x01  
_HTUR  
A.1.2 Analog AGC Configuration  
Informs the bit-pump software of the analog AGC configuration implemented in the design.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x02  
_ANALOG_AGC_CONFIG  
Options  
Data  
Option  
Description  
Field  
C Constant (api.h)  
Value  
No AGC  
No analog AGC is implemented, and constant receiver gain is  
used.  
0x00  
0x01  
0x02  
0x03  
_NO_AGC  
2-Step AGC  
4-Step AGC  
6-Step AGC  
Discrete analog AGC is used, with two possible gain levels. The  
gain value is controlled by pin AGC[0].  
_TWO_LEVEL_AGC  
_FOUR_LEVEL_AGC  
_SIX_LEVEL_AGC  
Discrete analog AGC is used, with four possible gain levels. The  
gain value is controlled by pins AGC[0] (LSB) and AGC[1].  
Discrete analog AGC is used, with six possible gain levels. The  
gain value is controlled by pins AGC[0] (LSB), AGC[1], and  
AGC[2].  
A-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
The Bt8960 bit-pump internally supports six different analog AGC configurations as shown in  
Table A-1. Three internal gain control signals are supplied by the Bt8960. In a 2-level discrete  
AGC configuration, pin AGAIN[0] is used to select between two discrete gain values, where a 0  
selects the lower gain. In a 4-level discrete AGC configuration, pin AGAIN[0] and AGAIN[1] are  
used to select between four discrete gain values, AGAIN[0] being the LSB. A 00selects the  
lowest gain. In a 6-level discrete AGC configuration, pin AGAIN[0], AGAIN[1] and AGAIN[2]  
are used to select between six discrete gain values, AGAIN[0] being the LSB. A 000selects the  
lowest gain.  
In a 6-level AAGC implementation, the recommended relative gain settings are 0 dB, 3 dB, 6  
dB, 9 dB, 12 dB, and 15 dB. In a 4-level AAGC implementation, the recommended relative gain  
settings are 0 dB, 3 dB, 6 dB, and 9 dB. In a 2-level AAGC implementation, the recommended  
relative gain settings are 0 dB and 6 dB. When no AGC is implemented, the fixed gain is referred to  
as the 0 dB level.  
NOTE: The 6-Level AGC setting should be set for optimal performance.  
Table A-1. Bt8960 AGAIN Settings  
C Constants  
_AGAIN0DB  
_AGAIN3dB  
_AGAIN6DB  
_AGAIN9DB  
_AGAIN12DB  
_AGAIN15DB  
Numeric Value  
AGAIN[2]  
AGAIN[1]  
AGAIN[0]  
0
1
2
3
4
5
0
0
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
A.1.3 Start-up Sequence Source  
Selects the the source of activation sequences to be external or internal. The Bt8960 provides for  
internally generated activation sequences that may be used in a complete stand-alone transceiver  
implementation. The internally generated activation sequences are 2- or 4-level scrambled 1s, with  
no HDSL framing information. These sequences do not meet the standard activation requirements  
which require HDSL framing information to be included in the activation sequences.  
100251B  
Conexant  
A-3  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
If a framed activation sequence is required, it must be supplied prior to any activation operation  
and the start-up sequence source must be set to external. Only a 4-level sequence need be supplied.  
The bit-pump ignores the magnitude bit during the initial 2-level transmission.  
NOTE: When the internal option is specified, the _TRANSMIT_EXT_DATA command must be  
called when the activation process is successfully completed.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x03  
_STARTUP_SEQ_SOURCE  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
External Start-up  
Sequence  
Start-up sequences are supplied externally. A 4-level  
activation sequence must be supplied before activation is  
initiated.  
0x00  
_EXTERNAL  
Internal Start-up  
Sequence  
Start-up sequences are generated internally. These sequences  
are 2/4 level scrambled 1s, with no HDSL framing.  
0x01  
_INTERNAL  
A.1.4 Transmit Scrambler  
Activates or bypasses the internal transmit scrambler. The internal transmit scrambler (and receive  
descrambler) may be used for stand-alone operation of the bit-pump. When activated, all incoming  
data is scrambled and then converted to quaternary symbols for transmission.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x04  
_TRANSMIT_SCR  
Options  
Description  
Data  
Field  
Option  
Bypass  
C Constant (api.h)  
The transmit scrambler is not used and the symbols supplied by the  
application are transmitted with no change.  
0x00  
_BYPASS  
Active  
The transmit scrambler is activated, and the bit stream supplied by  
the application is scrambled on chip before being transmitted.  
Standard scrambler taps are used (according to terminal type  
setting).  
0x01  
_ACTIVATE_SCR  
The TX scrambler is operated (when turned ON) only during 4-level  
transmission, i.e., during 4-level activation transmission and during  
normal operation.  
A-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
A.1.5 Receive Descrambler  
Activates or bypasses the internal receive descrambler. The internal receive descrambler may be  
used for stand-alone operation of the bit-pump. When activated, all detected symbols are converted  
to bits and descrambled, prior to being transferred to the data output pins. Note that all received bits  
are descrambled, including framing and overhead bits.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x05  
_RECEIVE_DESCR  
Options  
Description  
Data  
Field  
Option  
Bypass  
C Constant (api.h)  
The receive descrambler is not used and the detected symbols  
are supplied with no change.  
0x00  
0x01  
_BYPASS  
Active  
The receive descrambler is activated and the received bit stream  
is descrambled before being transferred.  
_ACTIVATE_DESCR  
100251B  
Conexant  
A-5  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
A.1.6 Data Transfer Format  
Selects the format in which data is transferred between the Bt8960 and the application. This option  
has no effect on data value, only the data transfer format is affected. Different data transfer formats  
allow for different schemes of framer bit-pump clock distribution. For more details, see the Bt8960  
datasheet.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x06  
_FRAMER_FORMAT  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
Parallel data,  
clock outputs  
The Bt8960 supplies a baud rate clock signal (QCLK) that times  
the data transfer in both the receive and transmit directions.  
Received quats are being transferred to the framer via the  
RQ[0], RQ[1] pins. Transmitted quats are being transferred to  
the bit-pump via the TQ[0], TQ[1] pins.  
0x00  
_PARALLEL_MASTER  
Parallel data,  
clock inputs  
A baud rate clock signal (RBCLK) is supplied that times the data  
transfer in the receive direction. Also supplied is a separate  
baud rate clock (TBCLK) that times the data transfer in the  
transmit direction. Received and transmitted quats are  
transferred via the TQ and RQ signals, as in Parallel with clock  
outputsmode. The RBCLK and TBCLK signals must be a  
derivative of the Bt8960s 16X clock at an arbitrary phase.  
0x01  
0x02  
0x03  
_PARALLEL_SLAVE  
Serial data  
The Bt8960 supplies a baud rate clock (on the QCLK pin) and a  
bit rate clock (on the RQ[0] pin) that time the data transfer in  
both receive and transmit directions. The received and  
transmitted quats are transferred serially, each on a single line,  
via the RQ[1] and TQ[1] pins. The 2B1Q magnitude bit is  
aligned to QCLK low and the 2B1Q sign bit is aligned to QCLK  
high.  
_SERIAL  
Serial Swap  
data  
The Bt8960 supplies a baud rate clock (on the QCLK pin) and a  
bit rate clock (on the RQ[0] pin) that time the data transfer in  
both receive and transmit directions. The received and  
transmitted quats are transferred serially, each on a single line,  
via the RQ[1] and TQ[1] pins. The 2B1Q magnitude bit is  
aligned to QCLK high and the 2B1Q sign bit is aligned to QCLK  
low. This format satisfies the ETSI/ANSI requirements for  
output quat orientation  
_SERIAL_SWAP  
A-6  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
A.1.7 Other Side Bt8960  
In a system where both terminals use Bt8960 bit-pumps, several activation operations can be  
performed more efficiently relative to the standard requirements. This command is used to inform  
the Bt8960 software that the other terminal uses a Bt8960 bit-pump.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x07  
_BT_OTHER_SIDE  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
Other side unknown  
The terminal on the other loop end is not known to use the  
Bt8960.  
0x00  
0x01  
_NO_BT  
Other side Bt8960  
The terminal on the other side of the loop employs a Bt8960.  
_BT  
A.1.8 LOST Time Period  
An on-chip timer is restarted when a loss of signal condition is detected. When this timer reaches a  
pre-defined value, the LOST status bit is turned ON. Once turned on, the status bit will not reset  
(even if there is no longer a LOS condition). The LOST indication is cleared only when an Activate  
or Reset command is issued.  
The LOST mechanism is active only after a Deactivate command is issued. Thus, during  
activation or normal operation, the LOST status is never set. This implementation is in  
correspondence with the T1E1/ETSI HDSL activation state diagrams. The LOST time interval is  
programmable in the range 031 seconds with a resolution of 1/10 second. The value of the LOST  
status bit may be checked using the Bit-pump Status command.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x08  
_LOST_TIME_PERIOD  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
LOST time period  
1-byte unsigned integer X. The LOST time period is set to X/10  
X
seconds.  
Default Value: 10 = 1 second.  
100251B  
Conexant  
A-7  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
A.1.9 Bit-pump ON/OFF  
Informs the Bt8960 software which bit-pumps are active in the system. Setting a bit-pump state to  
OFF causes the Bt8960 software to put the chip in a power-downmode and ignore any further  
control commands issued to this bit-pump, other than Bit-pump ON/OFF.  
All bit-pumps that are intended to be activated should be turned ON prior to any other control  
operation. The bit-pumps are numbered from 0 to 5. Any of the bit-pumps may be used in a system  
(note that a hardware implementation may include, for example, three bit-pumps, only two of  
which are turned ON).  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x09  
_SYSTEM_CONFIG  
Options  
Description  
Data  
Option  
C Constant (api.h)  
Field  
0x00  
0x01  
OFF  
ON  
Turn bit-pump OFF  
Turn bit-pump ON  
_NOT_PRESENT  
_PRESENT  
A.1.10 Transmit External Data  
This command should be used only when the activation sequence source is internal. When issued,  
this command causes the bit-pump to start transmission of externally supplied data symbols. This  
command should be issued upon the successful completion of activation, which is determined by  
the application, based on bit-pump and framer status responses. The transmitted data should be  
supplied to the bit-pump prior to issuing this command. Avoid situations where a long stream of  
constant value symbols is transmitted.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x0A  
_TRANSMIT_EXT_DATA  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
None  
0x00  
A-8  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
A.1.11 Activate  
Initiates the activation process. On an HTU-C terminal, this command causes 2-level activation  
sequence transmission to begin. On an HTU-R terminal, this command causes the bit-pump to wait  
for the detection of an incoming signal, and continue with the activation process when such a  
signal is detected. The activation process itself is fully automatic. An application may inquire about  
the activation status, SNR, etc., but otherwise no actions are required.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x0B  
_ACTIVATE  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
None  
0x00  
A.1.12 Deactivate  
Turns the transmitter off and stop all activation operations regardless of the current bit-pump status.  
The bit-pump goes to an IDLE state, where it awaits further commands. Issuing the Deactivate  
command enables the LOST mechanism (see the LOST Time Period command). If issued during  
normal operation, the receiver continues to function properly (useful for test purposes).  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x0C  
_DEACTIVATE  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
None  
0x00  
100251B  
Conexant  
A-9  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
A.1.13 Test Mode  
Operates the bit-pump in special test modes. These modes include maintenance operating modes  
and loopback configurations. To execute a bit-pump self-test procedure, use the Self-test status  
request command. To turn off any of the special test modes, use the Test Mode command with an  
_EXIT_TEST_MODE (0 value) parameter. All test modes except the two digital loopback modes  
require, after exiting the test mode, a complete activation procedure to be repeated (assuming  
normal operation is required). When exiting all these test modes (by issuing the Test Mode  
command with a 0 value parameter), the bit-pump is initialized to a reset state, and goes to the  
IDLE state, where it awaits further commands.  
The two digital loopback test modes do not interfere with the operation of the bit-pump, and  
only affect the received/transmitted symbol stream. Therefore, operating the bit-pump in a digital  
(near/far) loopback during normal operation will not cause loss of synchronization. Exiting one of  
these two test modes will turn off the loopback operation, allowing for normal data transfer to  
continue with no need for a restart. Table AA-2 summarizes the action taken when exiting  
different test modes.  
NOTE: When exiting a digital far loopbackmode, the transmitted symbol sequence source  
depends on the setting of the internal/external activation sequenceflag.  
Table A-2. Exiting Test Modes  
How to Go Back to Normal Data  
Transfer(1)  
Test Mode  
Digital Near  
Action Taken When Exiting Test Mode  
RX symbol stream (bit-pump to framer) is sent  
back to be the detected symbols sequence.  
Exit test mode.  
Loopback  
Digital Far Loopback  
External activation sequence mode: Transmit  
external data (TX scrambler is  
Exit test mode.  
operated/bypassed according to the Transmit  
Scrambler mode setting).  
Internal activation sequence mode: Transmit  
internally generated 4-level scrambled 1s  
sequence.  
Exit test mode. Issue Transmit External Data  
command to start transmitting the externally  
supplied (payload) data.  
All Other Test Modes  
Bit-pump initialized to a reset state, and goes to  
an IDLE state.  
Complete activation operation is required.  
(1)  
Assuming normal data transfer took place before issuing test mode  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
_TEST_MODE  
0x0D  
A-10  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
Options  
Description  
Cancel test mode. See Table A-1.  
Data  
Option  
C Constant (api.h)  
Field  
Exit Test Mode  
0x00 _EXIT_TEST_MODE  
0x01 _ANALOG_LOOPBACK  
External Analog  
Loopback  
Transmit the externally supplied TX symbols. Use the echo signal  
as a receivedsignal and detect the symbols using the standard  
equalizer.  
Digital NearLoop TX symbols supplied to the bit-pump by the framer are looped  
0x02 _NEAR_LOOPBACK  
0x03 _FAR_LOOPBACK  
Back  
back as the RX symbols going from the bit-pump to the framer.  
Useful for testing the framer and the framer/bit-pump connection.  
Digital Far”  
Loop Back  
Detected RX symbols are transmitted back on the loop. Useful for  
testing full 2-way transmission over a loop.(1)  
Transmit Isolated  
+3 Pulse  
Transmit (repeatedly) an isolated +3 level pulse. Useful for testing  
the transmitted pulse shape.  
0x04 _ISOLATED_PULSE_PLUS3  
0x05 _ISOLATED_PULSE_PLUS1  
0x06 _ISOLATED_PULSE_MINUS1  
0x07 _ISOLATED_PULSE_MINUS3  
0x08 _FOUR_LEVEL_SCR  
Transmit Isolated  
+1 Pulse  
Transmit (repeatedly) an isolated +1 level pulse  
Transmit (repeatedly) an isolated 1 level pulse  
Transmit (repeatedly) an isolated 3 level pulse  
Transmit Isolated  
1 Pulse  
Transmit Isolated  
3 Pulse  
Continuous 4-level  
Transmission  
Continuous transmission of a 4-level scrambled 1s sequence  
(internally generated). Useful for measuring transmitted power  
and spectral shape.  
Continuous 2-level  
Transmission  
Continuous transmission of a 2-level scrambled 1s sequence  
(internally generated).  
0x09 _TWO_LEVEL_SCR  
0x0A _VCXO_NOMINAL  
0x0B _VCXO_MIN  
Set Nominal VCXO Set VCXO control word to its nominal value. Useful for measuring  
Frequency VCXO center frequency.  
Set Minimum VCXO Set VCXO control word to its minimum value.  
Frequency  
Set Maximum  
Set VCXO control word to its maximum value.  
0x0C _VCXO_MAX  
VCXO Frequency  
Internal Analog  
Loop Back  
Transmits the externally supplied Tx symbols out the TXP and  
TXN pins and detects the symbols on the hybrid inputs (RXBP,  
RXBN), the receive inputs (RXP and RXN) are bypassed.  
0x0D _INTERNAL_ANALOG_  
LOOPBACK  
Isolated Analog  
Loop Back  
The externally supplied Tx symbols are internally looped back in  
the Bt8960. The transmitter (TXP and TXN) is turned off (silent).  
0x0E _ISOLATED_ANALOG_  
LOOPBACK  
(1)  
The operation of a digital farloopback requires activating the Bt8960 internal TX scrambler and RX descrambler.  
100251B  
Conexant  
A-11  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
A.1.14 Symbol Rate  
Informs the Bt8960 software of the bit-pump symbol rate. This value is used to convert seconds to  
symbols when absolute time interval measurements are performed using the symbol rate on-chip  
timers. This value must be programmed for proper bit-pump operation.  
NOTE: If the _SYM_RATE command is issued, then it must be called immediately after the  
_SYSTEM_CONFIG ON command. The _SYM_RATE command sets the PLL Clock  
Center Frequency. There is a potential for the bit-pump registers to get corrupted when the  
PLL Clock Frequency is changed. The _SYM_RATE command initializes the bit-pump  
registers to the default state after writing the PLL Clock Center Frequency. Therefore, the  
user must issue their application specific API Command Values after the _SYM_RATE  
command is issued.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x0E  
_SYM_RATE  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
Symbol rate  
1-Byte unsigned integer X, calculated according to:  
X=Symbol Rate / 4096.  
X
Default Value: 35=144 Ks/sec.  
A.1.15 Reset  
Loads bit-pump microcode, reset all bit-pump internal registers, and set all user-programmable  
options to their default values. After issuing a reset, all non-default user-programmable options  
should be reprogrammed using the appropriate commands. The Reset operation is automatically  
performed when turning a bit-pump ON using the Bit-Pump ON/OFF command. Therefore, under  
normal operating conditions, there should be no need for the Reset command.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x0F  
_RESET_SYSTEM  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A-12  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
A.1.16 Operate Non-Linear EC  
Selects between operating or disabling of the Bt8960 non-linear echo canceler.  
NOTE: The Non-Linear echo canceler is not functional in Bt8960 Rev A & B and should not  
be activated.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x11  
_OPERATE_NLEC  
Options  
Data  
Option  
Description  
C Constant (api.h)  
Field  
0x00  
0x01  
Disable NL EC  
Enable NL EC  
NL EC is not activated and not used  
NL EC operates normally  
_NLEC_OFF  
_NLEC_ON  
A.1.17 Write Transmitter Gain  
Writes the Transmitter Gain Register. The Transmitter Gain register is a 4-bit, 2s complement  
value. The upper 4 bits of this field are ignored. The Tx Gain adjusts the nominal transmit power of  
the Bt8960. The Tx Gain ranges from 1.6 dBm (1000b) to +1.4 dBm (0111b) of the nominal  
transmit power level.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x13  
_WRITE_TX_GAIN  
Options  
Data  
Field  
Option  
Description  
4-bit, 2s complement integer.  
C Constant (api.h)  
Tx Gain  
Value  
100251B  
Conexant  
A-13  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.1 Control Commands  
Software Users Guide  
A.1.18 Tip/Ring Reversal  
Reverses the Tip/Ring polarity on the received signal. However, the Bt8960 does not reverse the  
Tip/Ring polarity on the transmitted signal. In addition, the Bt8960 does not provide the ability to  
detect when Tip/Ring reversal is necessary.  
This command is useful in applications where a framer has the ability to detect Tip/Ring  
reversal but can not correct the Tip/Ring reversal. Since this command only reverses the received  
signal, it is necessary to call this command on both the Central and Remote terminals when  
Tip/Ring reversal is detected.  
NOTE: This command is only supported by Versions 2.0+.  
Opcode  
Numeric Value  
Opcode  
0x14  
_REVERSE_TIP_RING  
Options  
Data  
Field  
C Constant (defined in file  
api.h)  
Option  
Tip/Ring  
Description  
Sets the Tip/Ring polarity on the received signal to normal  
(not-reversed).  
0x00  
0x01  
Normal  
Tip/Ring  
Reverse  
Reverses the Tip/Ring polarity on the received signal.  
A.1.19 BER Meter Start  
Activates the BER Meter. The bit-pump is set to transmit an internal 4-Level scrambled ones  
pattern. The enabled bit is set and the bit_errors & meter_intervals variables are reset to 0. This  
command should only be called during the Bit-pumps normal operation.  
NOTE: This command is only supported by Versions 2.0+.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x15  
_BER_METER_START  
A-14  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.1 Control Commands  
Options  
Data  
Field  
Option  
Description  
C Constant (defined in file api.h)  
None  
0x00  
A.1.20 BER Meter Stop  
Deactivates the BER Meter. The bit-pump is set to transmit external 4-Level data, the transmit  
scrambler is set based on the current _TRANSMIT_SCR API setting. The enabled bit is turned  
OFF. The bit_errors and meter_intervals variables are unmodified so they can be still read.  
NOTE: This command is only supported by Versions 2.0+.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x16  
_BER_METER_STOP  
Options  
Option  
Description  
Data Field  
C Constant (defined in file api.h)  
None  
0x00  
100251B  
Conexant  
A-15  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
A.2Status Request Commands  
Status request commands are used to get performance monitoring information from the bit-pump.  
These commands do not affect bit-pump operation in any way. The bit-pump response to all status  
request commands is a 1-byte response.  
For each status request command, the type and format of information supplied, and the  
command opcode and the options are described.  
A.2.1 Input Signal Level  
Requests the level of the average signal level at the ADC input.  
NOTE: The signal at the ADC input consists of a large transmitted echo component, and a  
smaller far-end signal component. Thus, no cable attenuation data may be extracted  
from this information.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x80  
_SLM  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.1.1 Bit-pump Response  
Unsigned integer X, 0 X 255, relative to the average absolute value of the ADC input signal.  
The measurement scale is such that a value of 255 corresponds to the ADC positive full scale  
value.  
A.2.2 Input DC Offset  
Requests the value of the average DC level at the ADC input.  
NOTE: Any level of input DC offset is digitally canceled on-chip, but large DC offsets (>2%  
of full scale) may degrade performance because of the reduction in effective ADC  
dynamic range.  
A-16  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
Opcode  
Options  
Numeric Value  
0x81  
C Constant (defined in file api.h)  
_DC_METER  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.2.1 Bit-pump Response  
Signed integer X, 128 X 127, relative to the average DC offset per ADC sample. The  
measurement scale is such that the actual DC offset in units of ADC LSB is 32X. In case the actual  
DC offset is outside the representable range (4096 to 4095), the nearest representable value will  
be used.  
A.2.3 Far-End Signal Attenuation  
Requests a value of the far-end signal attenuation. This value is based on measuring the average  
far-end signal level after echo cancellation.  
The result is calibrated to represent the overall signal power attenuation over the cable in dB. It  
is also calibrated for an analog gain value of 0 dB, with an absolute gain value as implemented in  
Brooktrees HDSL EVM system. When using a different analog gain value, or an AAGC gain  
selection other than 0 dB, the signal attenuation result must be scaled accordingly. For example, if  
an analog gain value of 6 dB is used, the actual signal attenuation is 6 dB larger than reported. Note  
also that this value depends on the transmitted power at the far-end side, and is calibrated for the  
nominal 13.5 dBm value.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x82  
_FELM  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.3.1 Bit-pump Response  
1-Byte unsigned integer X, 0 X 255, indicating the overall signal power attenuation, in units of  
0.5 dB. For example, a value of 60 means total cable attenuation of 30 dB.  
100251B  
Conexant  
A-17  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
A.2.4 Noise Margin  
Requests a value of the noise margin (NMR) of the receiver. The noise margin is defined as the  
maximum tolerable increase in external noise power that still allows for BER of less than 1E7.  
The value is based on measuring the average absolute level of the noise at the input to the  
slicer. In order to get a stable response, it is recommended that the average of 10 noise margin  
readings is used to reduce the statistical measurement error.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x83  
_NMR  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.4.1 Bit-pump Response  
1-Byte signed integer X, 128 X 127, indicating the noise margin in units of 0.5 dB. For  
example, a value of 8 means a noise margin of 4 dB.  
A.2.5 Timing Recovery Control  
Requests a value of the Timing Recovery Control circuit. This value indicates the timing recovery  
frequency relative to its center frequency, which does not necessarily equal the nominal  
transmission frequency. On an HTU-C terminal, this response will always be zero since the control  
circuit is set to its nominal value. On an HTU-R terminal, this value gives an estimate of the  
frequency offset relative to the center frequency. The relation of the given value with the frequency  
offset in Hz depends on the timing recoverys slope.  
NOTE: This replaces the _VCXO_CONTROL_VOLTAGE API command found in existing  
Brooktree HDSL products.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x84  
_TIMING_RECOVERY_CONTROL  
A-18  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
Options  
Data  
Option  
Description  
C Constant (api.h)  
Field  
None  
0x00  
A.2.5.1 Bit-pump Response  
Signed integer X, 128 X 127, indicating the 8 MSBs of the timing recovery control word.  
A.2.6 Bit-Pump Status  
Requests bit-pump status. The status bits are designated I0 (LSB) to I7 (MSB), and interpreted  
according to Table A-2.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x85  
_STARTUP_STATUS  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
100251B  
Conexant  
A-19  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
A.2.6.1 Bit-pump Response  
Table A-3. Status Bits  
Status  
Bit  
Indicates  
Value = 0  
Value = 1  
I0  
(LSB)  
LOS: A LOS condition is defined as the absence of a far-end signal at  
the receiver input.  
No LOS condition  
No LOST condition  
LOS condition  
LOST condition  
I1  
LOST: A LOST condition is defined as a continuously active LOS  
condition for more than a period of LOST seconds. The LOST period is  
user programmable (see the LOST Time Period command).  
I2  
I3  
Reserved  
Activation timer: On an HTU-R, the Activation timer is activated when  
2-level transmission begins. On an HTU-C, the Activation timer is  
activated when an Activate command is issued and 2-level  
transmission begins. The timer is restarted when a far-end (HTU-R)  
signal is detected.  
Timer not expired  
Timer expired  
Note: The Activation Timer defaults to 50 seconds for a 288kbps data  
rate system  
I4  
Noise Margin OK: Indicates that the noise margin is better than a  
Noise margin  
Noise margin  
threshold of 5 dB.  
5dB  
> 5 dB  
I5  
I6  
Reserved  
Transmitter 4-Level Indicator: indicates that a 4-Level signal is being  
transmitted.  
Not transmitting  
4-Level  
Transmitting  
4-Level  
I7  
Normal Operation Flag: This bit is set when the Bit-pump successfully  
completes startup. This bit is cleared when the startup is first  
Activated, when the Deactivate command is issued, and when  
Initialized.  
Not Normal  
Operation  
Normal  
Operation  
A.2.7 Read Linear Echo Canceler Coefficient  
Reads a specified Linear Echo Canceler coefficient.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x86  
_LEC_COEFF  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
Coefficient index  
Unsigned integer X, 0 X 59, indicating the index of  
X
the linear EC coefficient to be read.  
A-20  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
A.2.7.1 Bit-pump Response  
1-Byte signed integer X, containing the 8 MSBs of the requested Linear EC coefficient value.  
A.2.8 Read Non-Linear Echo Canceler Coefficient  
Reads a specified Non-Linear Echo Canceler Coefficient.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x87  
_NLEC_COEFF  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
Coefficient index  
Unsigned integer X, 0 X 63, indicating the index of  
X
the non-linear EC coefficient to be read.  
A.2.8.1 Bit-pump Response  
Signed integer X, containing the 8 MSBs of the requested non-linear EC coefficient value.  
A.2.9 Read EQ Coefficient  
Reads a specified DAGC, FFE, or EP coefficient.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x88  
_EQ_COEFF  
100251B  
Conexant  
A-21  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
Options  
Description  
Data  
Field  
Option  
C Constant (api.h)  
FFE coefficients  
FFE Data Taps  
EP coefficients  
EP Data Taps  
DAGC gain  
Request FFE coefficients 07  
Request FFE Data Taps 07  
07  
815  
Request EP coefficients 04  
Request EP Data Taps 04  
1620  
2125  
Request DAGC gain value LSB  
Request DAGC gain value MSB  
26  
27  
DAGC Output  
FFE Output  
DAGC Input  
Request DAGC Output  
28  
29  
30  
31  
Request FFE Output  
Request DAGC Input  
FFE Output, delayed 1  
Symbol  
Request FFE Output, delayed 1 Symbol  
DAGC Error Signal  
Request DAGC Error Signal  
32  
33  
Equalizer Error  
Signal  
Request Equalizer Error Signal  
Slicer Error Signal  
Reserved  
Request Slicer Error Signal  
34  
3547  
A.2.9.1 Bit-pump Response  
Signed integer containing the 8 MSBs of the requested EQ coefficient value.  
A.2.10 Read DFE Coefficient  
Reads a specified DFE coefficient.  
Opcode  
Options  
Numeric Value  
C Constant (defined in file api.h)  
0x89  
_DFE_COEFF  
Data  
Field  
Option  
Description  
C Constant (api.h)  
Coefficient index  
Unsigned integer X, 0 X 57, indicating the index  
X
of the DFE coefficient to be read.  
A-22  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
A.2.10.1 Bit-pump Response  
Signed integer X, containing the 8 MSBs of the requested DFE coefficient value.  
A.2.11 Software/Chip Version  
Requests software and chip version numbers.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8A  
_VERSION  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
Major SW Version  
Chip Version  
The 4 LSBs of the status byte (bit 0bit 3) contain the  
bit-pump major software version, bit 0 being the LSB.  
The 4 MSBs of the status byte (bit 4bit 7) indicate the  
bit-pump chip version, bit 4 being the LSB  
0x00  
_HW_SW_VERSIONS  
Major SW Version  
Minor SW Version  
1-Byte unsigned integer field returning the major  
software version.  
0x01  
0x02  
0x03  
_MAJOR_SW_VERSION  
_MINOR_SW_VERSION  
_HW_TYPE_VERSIONS  
1-Byte unsigned integer field returning the minor  
software version.  
Bit-pump Type  
Chip Version  
The 3 LSBs of the status byte (bit 0bit2) contain the  
bit-pump type (see table below). Bit 3 is undefined.  
The 4 MSBs of the status byte (bit 4bit 7) indicate the  
bit-pump chip version, bit 4 being the LSB.  
Bit-pump Types  
Bits 2-0  
Bit-pump Type  
Bt8952  
000  
001  
Bt8960  
010111  
undefined  
100251B  
Conexant  
A-23  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
A.2.12 Bit-pump Present  
Requests a bit-pump presence status. A positive response means that the bit-pump is present in the  
system and connected to the microprocessor. The presence of a bit-pump is determined by  
performing a write/read operation to a single internal bit-pump RAM location. It is possible for  
hardware faults to masquerade as the presence of a bit-pump at a location. The presence of a  
bit-pump does not guarantee that all microprocessor bit-pump hardware connections are OK.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8B  
_BIT_PUMP_PRESENT  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.12.1 Bit-pump Response  
0x00: Bit-pump not present  
0x01: Bit-pump present  
A.2.13 Self Test  
Executes a bit-pump self-test. The self-test does not cover all aspects of the chip operation, but  
verifies read/write operations.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8C  
_SELF_TEST  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.13.1 Bit-pump Response  
0x00: Bit-pump self-test pass  
0x01: Bit-pump self-test fail  
A-24  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
A.2.14 Read Bt8960 Register  
Reads an internal Bt8960 register. Register address is required.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8D  
_REGISTER  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
Bt8960 register  
address  
Address of internal Bt8960 register to be read. See Bt8960  
datasheet for register address map.  
X
A.2.14.1 Bit-pump Response  
Value stored in specified Bt8960 internal register.  
A.2.15 Bit-pump Configuration  
Requests a bit-pump configuration. This includes user programmable options and parameters.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8E  
_CONFIGURATION  
Option  
Data  
Field  
Option  
Read low  
application setup  
byte  
Description  
C Constant (api.h)  
Read low byte of application setup word. See Table  
A-3 for structure of application setup word.  
0x00  
_USER_SETUP_LOW_BYTE  
_USER_SETUP_HIGH_BYTE  
_LOST  
Read high  
application setup  
byte  
Read high byte of application setup word. See Table  
A-4 for structure of application setup word.  
0x01  
0x02  
0x03  
Read LOST time  
period  
Read LOST time period. The format of this status  
byte is identical to the format in the LOST Time  
Period command.  
Read symbol rate  
Read symbol rate. The format of this status byte is  
identical to the format in the Symbol Rate command.  
_BIT_RATE  
100251B  
Conexant  
A-25  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
Table A-4. Low Application Setup Byte  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reserved  
Other side  
Bt8960  
Receive  
descr.  
Transmit  
scramb.  
Start-up  
sequence  
source  
Analog AGC  
Config 1  
Analog AGC  
Config 0  
Terminal  
type  
Table A-5. High Application Setup Byte  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Test mode  
3
Test mode  
2
Test mode  
1
Test mode  
0
Reserved  
Reserved  
Data  
transfer  
format 1  
Data  
transfer  
format 0  
All fields of the application setup word are coded in exactly the same way as the data field byte in  
the corresponding control command. For example, the two Data Transfer Format bits (bits 0,1 of  
the high application setup byte) are interpreted exactly the same as the data field byte in the Data  
Transfer Format command.  
The 4 test mode bits (Test mode 0Test mode 3) show the current test mode index (numbered  
from 0 to 14) with Test Mode 0 being the LSB. A zero value indicates that no test mode is currently  
in effect. A non-zero value indicates that the bit-pump currently operates in the specified test  
mode. See the Test Mode command.  
A.2.16 Stage Number  
Gets the bit-pump software stage number.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x8F  
_STAGE_NUMBER  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.16.1 Bit-pump Response  
The Bt8960 software internal stage number. This stage number changes when the bit-pump goes  
through a activation procedure. File suc.h contains C definitions mapping the stage numbers to  
stage names. This command is only used for test and debug purposes.  
A-26  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.2 Status Request Commands  
A.2.17 AAGC Value  
Gets the current value of the 3 AAGC control bits.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x90  
_AAGC_VALUE  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
None  
0x00  
A.2.17.1 Bit-pump Response  
The 3 LSBs of this status byte reflect the state of the AAGC control bits. This command is useful  
for calculating the true signal attenuation by compensating for the actual AAGC gain (see Far-End  
Signal Attenuation command).  
A.2.18 Read Tx Gain  
Reads the Transmitter Calibration/Gain registers. The Transmitter Gain registers are a 4-bit, 2s  
complement value. The upper 4 bits of this field are ignored.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x91  
_READ_TX  
Options  
Data  
Field  
Option  
Description  
C Constant (api.h)  
Tx Calibration  
Tx Gain  
Transmitter Calibration Register  
Transmitter Gain Register  
0x00  
0x01  
_CALIBRATION  
_GAIN  
A.2.18.1 Bit-pump Response  
The Tx Calibration Register contains the nominal setting for the transmitter gain. The Tx Gain  
Register contains the current transmitter gain setting. On software initialization, the Tx Gain  
register is programmed to the Tx Calibration register.  
100251B  
Conexant  
A-27  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.2 Status Request Commands  
Software Users Guide  
A.2.19 BER Meter Status  
Request the BER Meter Status. Reading the BER Meter status commands while the BER Meter is  
enabled does not effect the BER meter operation.  
NOTE: This command is only supported by Versions 2.0+.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x92  
_BER_METER_STATUS  
Options  
Data  
Field  
Option  
BER Status  
Description  
C Constant (defined in file api.h)  
_BER_STATUS  
Read the BER Meter Status, see the  
BER Status below for bit definitions.  
0x00  
# Bit Errors Low Byte  
# Bit Errors High Byte  
Reads the low byte of the number of  
bit-errors.  
0x01  
0x02  
0x03  
0x04  
_BER_BIT_ERRORS_LOW  
Reads the high byte of the number  
of bit-errors.  
_BER_BIT_ERRORS_HIGH  
# Meter Intervals Low  
Byte  
Reads the low byte of the number of  
meter intervals elapsed.  
_BER_METER_INTERVALS_LOW  
_BER_METER_INTERVALS_HIGH  
# Meter Intervals High  
Byte  
Reads the high byte of the number  
of meter intervals elapsed.  
BER Status Bits  
Status  
Bit  
Indicates  
Value = 0  
Value = 1  
Active  
0
BER Meter Enabled  
Reserved  
Not Active  
1-7  
A-28  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix A Command Set Reference  
Software Users Guide  
A.3 Special Messages  
A.3Special Messages  
A.3.1 Acknowledge  
This message is sent by the 8032 to acknowledge a correctly received message, in a serial  
communication UI configuration. The acknowledge message is 4 bytes long (like all other  
messages), with the first 3 being 0xFF, 0xFF, 0xFF. Byte 4 (last transmitted) is the standard  
checksum byte, which equals 0x55.  
100251B  
Conexant  
A-29  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix A Command Set Reference  
Bt8960  
A.3 Special Messages  
Software Users Guide  
A-30  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
B
Appendix B Calibrating Noise Margin Table  
B.1Introduction  
The Noise Margin Table defined in module USER.C is calibrated to W & G ILS 200 ETSI Loop 2  
with 1.5 MHz shaped noise with low crest factor. This document describes the steps needed to  
calibrate the noise margin table to a users specific noise source. The Noise Margin Table has a 0.5  
dB resolution.  
B.1.1 Setup  
Use a line simulator or true line and a noise generator. Select a simple standard loop like ISDN  
Loop 2 and perform startup. Connect a BER meter to the HDSL equipment.  
B.1.2 Noise Margin Table Calibration  
B.1.2.1 Calculate scale factor.  
1. Read meter timer high byte address 0x19, using the API command :  
_BtStatus (loop_no, _REGISTER, 0x19, &scale);  
2. Calculate scale factor.  
scale_factor = ( (2^7) / scale);  
B.1.2.2 Find 0 dB Noise Margin Reference Point.  
1. Change the noise source until BER reading is 1.0e7 (for 1 loop) or 5.0e8 (for 2 loops).  
This point is the 0 dB Noise Margin reference point  
100251B  
Conexant  
B-1  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix B Calibrating Noise Margin Table  
Bt8960  
B.1 Introduction  
Software Users Guide  
B.1.2.3 Calculate reference point value.  
1. Read NLM meter low byte address 0x50, using the API command:  
_BtStatus (loop_no, _REGISTER, 0x50, &low_byte);  
2. Read NLM meter high byte address 0x51, using the API command:  
_BtStatus (loop_no, _REGISTER, 0x51, &high_byte);  
3. Combine the two NLM bytes (low_byte and high_byte) to an integer:  
nlm_value = 256 * high_byte + low_byte;  
4. Calculate the normalized value of noise level meter:  
nlm_value = nlm_value * (2^scale factor);  
5. Repeat steps 1 to 4 ten times. Calculate the average nlm_value over the ten readings.  
B.1.2.4 Set 0dB reference point.  
1. Write the averaged value of noise level meter to cell 32 in the _noise_margin[] array,  
module USER.C.  
B.1.2.5 Calculate +0.5dB Margin.  
1. Decrement the noise source by 0.5 dB.  
2. Repeat the Calculate Reference Point Value step B.1.2.3 (1 to 5).  
3. Write the calculated value to next higher cell.  
B.1.2.6 Calculate positive margin.  
1. Repeat step B.1.2.5 (1 to 3) until the upper half of the table if full. The significant part of  
the table is 0 dB to 15 dB noise margin. Higher margins can not be measured reliably.  
B.1.2.7 Set Noise Source to 0dB.  
1. Set the noise source to the 0 dB noise margin reference point.  
B.1.2.8 Calculate 0.5 dB Margin.  
1. Increment the noise source by 0.5 dB.  
2. Repeat the Calculate Reference Point Value step B.1.2.3 (1 to 5).  
3. Write the calculated value to next lower cell.  
B.1.2.9 Calculate negative margin.  
1. Repeat step B.1.2.8 (1 to 3) until the lower half of the table is full.  
B-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
C
Appendix C ERLE Diagnostic Code  
C.1Introduction  
The ERLE program is a diagnostic tool to verify the integrity of the hardwares analog front-end  
and echo canceler. The ERLE program is useful when modifying the hybrid for different data rates.  
C.2What is ERLE?  
ERLE = Echo Return Loss Enhancement.  
Four results are given from the ERLE program.  
1. Background Noise Test  
2. ERLE  
3. Analog ERLE  
4. AAGC Check  
The background test measures the SLM while the transmitter is turned off. This effectively  
gives the amount of noise present at the input of the A/D.  
The ERLE result determines the amount of echo canceled. The echo is canceled initially by the  
external hybrid and then by the Linear Echo Canceler in the bit-pump. The ERLE measurement is  
determined by the following formula.  
ERLE = 20 * log ( SLM / FELM )  
SLM = Signal Level Meter  
FELM = Far End Level Meter  
The Analog ERLE determines how much echo is canceled by the hybrid. This is done by  
bypassing the hybrid and measuring the input signal level meter. The Analog ERLE measurement  
is determined by the following formula.  
ERLE = 20 * log ( SLM2 / SLM )  
SLM2 = Signal Level Meter with hybrid input bypassed  
SLM = Signal Level Meter from ERLE result  
The AAGC Check makes sure the gain settings are monatomic. The AAGC is the bit-pumps  
internal Analog Automatic Gain Control.  
100251B  
Conexant  
C-1  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix C ERLE Diagnostic Code  
Bt8960  
C.3 ERLE Files  
Software Users Guide  
C.3ERLE Files  
The ERLE.C and ERLE.H files found in the bit-pump directory contains the ERLE functions.  
Prior to calling these functions, the bit-pump must be configured using the appropriate API  
commands.  
Routine  
Description  
_Erle()  
Contains the ERLE diagnostic code. _Erle() is used to measure the Background Noise, ERLE, and  
Analog ERLE.  
_MeasureAagc()  
This function cycles through the AAGC settings and measures the SLM to make sure the gain  
settings are monatomic.  
C.3.1 _ERLE()  
The _ERLE() routine measures the Background Noise, ERLE, and Analog ERLE.  
Parameters: no - which bit-pump, _BIT_PUMP0 - _BIT_PUMP6  
mode - mode of operation  
The mode bits are defined as follows:  
Bit  
Description  
0
Adapt Non-linear Echo Canceler. A 0does not adapt the NLEC. A 1adapts the NLEC.  
1
Reserved  
2,3,4  
Select AGAIN setting. These 3 bits correspond to the 3 Gain Control bits of the ADC Control Register  
(0x21).  
000 = 0dB  
001 = 3 dB  
010 = 6 dB  
011 = 9 dB  
100 = 12 dB  
101 = 15 dB  
5,6,7  
Reserved  
C.3.2 _MeasureAagc()  
The _MeasureAagc() routine verifies the gain settings are monatomic.  
Parameters:no- which bit-pump, _BIT_PUMP0 - _BIT_PUMP6  
C-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix C ERLE Diagnostic Code  
Software Users Guide  
C.4 Invoking the Tests  
C.4Invoking the Tests  
C.4.1 Background Test  
To perform the Background Noise Test, call _Erle() when the transmitter is OFF. In this mode, the  
program adapts the LEC (linear echo canceler). If the NLEC (non linear echo canceler) mode is on,  
then the NLEC is also adapted. After adapting the coefficients, the SLM and FELM are read and  
ERLE is calculated. The ERLE number is not important here, what is important are the SLM and  
FELM register values.  
C.4.2 ERLE and Analog ERLE Test  
To perform the ERLE and Analog ERLE test, call _Erle() when the transmitter is ON. In this mode,  
the program adapts the LEC (linear echo canceler). If the NLEC (non linear echo canceler) mode is  
on, then the NLEC is also adapted. After adapting the coefficients, the SLM and FELM are read  
and ERLE is calculated. After that, the hybrid bypass bit is set and Analog ERLE is calculated.  
C.4.3 AAGC Check  
To perform the AAGC Check test, call the _MeasureAagc() when the transmitter is ON.  
C.5Compiling the ERLE Code  
The ERLE code requires the compiler flag ERLE to be specified in the compiler flag define list.  
C.5.1 TDEBUG Compiler Flag  
The TDEBUG compiler is typically specified when generating the ERLE code. The TDEBUG  
provides a printf()environment to display the results. In the TDEBUG environment, an RS232  
cable must be connected to a terminal emulator.  
NOTE: The SER_COM compiler flag can not be specified at the same time as the TDEBUG  
flag.  
However, it is possible to compile without the TDEBUG flag. If this is the case, then the user  
would be responsible for extracting the results.  
100251B  
Conexant  
C-3  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix C ERLE Diagnostic Code  
Bt8960  
C.5 Compiling the ERLE Code  
Software Users Guide  
C-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
D
Appendix D Release Notes  
Appendix D contains the previous release notes for the Bt8960 software. These notes have also  
been incorporated into their respective sections within this users guide.  
NOTE: Bt8960 Bit-pump Version 2.0, Release NotesNovember 13, 1996  
D.1Memory Requirements  
The RAM and ROM requirements for four common build options with their associated compiler  
flags are given in Table D-1.  
Table D-1. RAM and ROM Requirements  
Build Option  
RAM  
111  
117  
117  
117  
ROM  
24.0 k  
24.4 k  
20.0 k  
20.6 k  
BT8960CR w/o BER_METER  
BT8960CR w/ BER_METER  
BT8960C w/ BER_METER  
BT8960R w/ BER_METER  
NOTE(S): The RAM requirements do not include the stack size, an additional 24 bytes is required for the run-time stack.  
D.1.0.1 BT8960CR w/o BER_METER  
C51, ADD_DELAY, PDATA_MODE, SER_COM, HTUC, HTUR, SINGLE_LOOP,  
CHAN_UNIT  
D.1.0.2 BT8960CR w/ BER_METER  
C51, ADD_DELAY, PDATA_MODE, SER_COM, HTUC, HTUR, SINGLE_LOOP,  
BER_METER, CHAN_UNIT  
D.1.0.3 BT8960C w/ BER_METER  
C51, ADD_DELAY, PDATA_MODE, SER_COM, HTUC, SINGLE_LOOP, BER_METER,  
CHAN_UNIT  
100251B  
Conexant  
D-1  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix D Release Notes  
Bt8960  
D.1 Memory Requirements  
Software Users Guide  
D.1.0.4 BT8960R w/ BER_METER  
C51, ADD_DELAY, PDATA_MODE, SER_COM, HTUR, SINGLE_LOOP, BER_METER,  
CHAN_UNIT  
D.1.1 Bug Fixes  
The following bugs were fixed in Version 2.0.  
D.1.1.1 HTU-C Phase #0 = 0 vs AagcCheck() Bug  
When the AagcCheck() incremented the gain setting, the Linear EC was not re-adapted so the first  
phase quality (phase #0) always reported 0. To solve this, in the START_OPEN_EYE stage, always  
set the next stage to PHASE_ADAPT_EC1 instead of OPEN_EYE1; this will force the Echo  
Canceler to be re-adapted. Fixing this bug improves startup reliability and performance.  
D.1.1.2 External and Internal Analog Loopback  
The External and Internal Analog loopback function did not work properly in Version 1.x. Please  
see the Analog Loopbacks section below for details.  
D.1.2 Support new Bt8960 Rev C  
Version 2.0 supports the new Bt8960 Rev C silicon. The Bt8960 Rev C is identified by the  
package marking PROTO3 or ES2, and the chip revision number 1 in the global modes register  
(Addr. 0x00) and JTAG ID register. Version 2.0 is backwards compatible with the existing Bt8960  
Rev A & B parts. However, the existing Version 1.x Bt8960 Bit-pump Software is not forward  
compatible with the new Rev C parts.  
D.1.2.1 _ReadAccessDataByte() function  
When reading the indirect RAM (i.e. linear echo canceler, equalizer register, etc.) of the Bt8960  
Rev C silicon, there can not be any other write operations to the Bt8960 after the indirect RAM  
read address register (i.e. Addr: 0x70, 0x72, etc.) is selected and before the Access Data Byte  
registers (Addr: 0x7C-0x7F) are read.  
In the Bt8960 code, the only time this condition is violated is if an interrupt occurs in between  
selecting the read address and reading the access data bytes. The _ReadAccessDataByte() function  
disables the interrupts whenever reading the indirect RAM and re-enables the interrupts on exit.  
The four Access Data Byte registers are stored in the global_access_data_byte[] array. The  
calling function or routine then just accesses this global array without interfering with the bit-pump  
registers.  
D.1.2.2 Analog Loopbacks  
The Bt8960 Rev C silicon fixed the Isolated Analog loopback. Please see the Analog Loopbacks  
section below for details.  
D-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix D Release Notes  
Software Users Guide  
D.1 Memory Requirements  
D.1.3 Improved Performance  
The startup reliability and performance for ANSI Loops #1 & #2 and maximum reach were  
significantly improved.  
D.1.3.1 Phase Quality Selection  
In Bit-pump Version 1.x, a Bt8960 system would occasionally select the incorrect optimal phase on  
some of the more difficult loops. During this bad startup, the system would successfully pass data  
but the noise margin would be noticeably worse than a good startup. In addition, the Bt8960 could  
not startup on ANSI Loops #1 and #2. Version 2.0 modified the optimal phase selection to provide  
a more robust algorithm for the Bt8960 systems. This provides more reliable startups, the ability to  
startup on ANSI Loops #1 & #2, and gains more maximum reach.  
NOTE: This improvement applies to both Rev B and Rev C silicon.  
D.1.4 New / Modified Features  
The following features were added or fixed in Version 2.0.  
D.1.4.1 Implemented Internal BER Meter  
Implemented the Bt8960 internal BER Meter. Please see the Internal BER Meter Operation  
section below for details.  
D.1.4.2 READ_METER_REG() Macro  
During the BER Meter operation, the bit-pump interrupt handler reads the BER Meter register  
every meter interval. To insure that the interrupt doesnt occur in between reading the low byte and  
high byte of another meter register, the READ_METER_REG() macro disables the bit-pump  
interrupt when accessing any of the meter registers.  
D.1.4.3 Analog Loopbacks  
The Bt8960 supports 3 types of analog loopbacks: External, Internal, and Isolated.  
1. ExternalTransmitter ON, receiver uses both the receive (RXP, RXN) and hybrid (RXBP,  
RXBN) inputs.  
2. InternalTransmitter ON, receiver only uses the hybrid inputs (RXBP, RXBN).  
3. IsolatedTransmitter silent, internally loopbacked.  
Table D-2 shows the relationship between the Chip Rev, Software Version, and Analog  
Loopbacks supported.  
Table D-2. Version Relationships  
Version External  
Internal  
Isolated  
V 1.x  
V 2.0  
None  
None  
None  
Rev C only  
Rev B and C  
Rev C only  
100251B  
Conexant  
D-3  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix D Release Notes  
Bt8960  
D.1 Memory Requirements  
Software Users Guide  
D.1.5 New API Commands  
The following API commands were added in Version 2.0.  
D.1.5.1 Tip/Ring Reversal  
This command reverses the Tip/Ring polarity on the received signal. However, the Bt8960 does  
not reverse the Tip/Ring polarity on the transmitted signal. In addition, the Bt8960 does not  
provide the ability to detect when Tip/Ring reversal is necessary.  
This command is useful in applications where a framer has the ability to detect Tip/Ring  
reversal but can not correct the Tip/Ring reversal. Since this command only reverses the received  
signal, it is necessary to call this command on both the Central and Remote terminals when  
Tip/Ring reversal is detected.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x14  
_REVERSE_TIP_RING  
Options  
Data  
Field  
C Constant (defined in file  
api.h)  
Option  
Tip/Ring  
Description  
Sets the Tip/Ring polarity on the received signal to normal  
(not-reversed).  
0x00  
0x01  
Normal  
Tip/Ring  
Reverse  
Reverses the Tip/Ring polarity on the received signal.  
D.1.5.2 BER Meter Start  
This command activates the BER Meter. The bit-pump is set to transmit an internal 4-Level  
scrambled ones pattern. The enabled bit is set and the bit_errors & meter_intervals variables are  
reset to 0. This command should only be called during the Bit-pumps normal operation.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x15  
_BER_METER_START  
Options  
Option  
Description  
Data Field  
C Constant (defined in file api.h)  
None  
0x00  
D-4  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix D Release Notes  
Software Users Guide  
D.1 Memory Requirements  
D.1.5.3 BER Meter Stop  
This command deactivates the BER Meter. The bit-pump is set to transmit external 4-Level data,  
the transmit scrambler is set based on the current _TRANSMIT_SCR API setting. The enabled bit  
is turned OFF. The bit_errors & meter_intervals variables are unmodified so they can be still  
read.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x16  
_BER_METER_STOP  
Options  
Option  
Description  
Data Field  
C Constant (defined in file api.h)  
None  
0x00  
D.1.5.4 BER Meter Status  
Request the BER Meter Status. Reading the BER Meter status commands while the BER Meter is  
enabled does not effect the BER meter operation.  
Opcode  
Numeric Value  
C Constant (defined in file api.h)  
0x92  
_BER_METER_STATUS  
Options  
Data  
Field  
Option  
BER Status  
Description  
C Constant (defined in file api.h)  
_BER_STATUS  
Read the BER Meter Status, see the BER  
Status below for bit definitions.  
0x00  
# Bit Errors Low  
Byte  
Reads the low byte of the number of  
bit-errors.  
0x01  
0x02  
0x03  
0x04  
_BER_BIT_ERRORS_LOW  
# Bit Errors High  
Byte  
Reads the high byte of the number of  
bit-errors.  
_BER_BIT_ERRORS_HIGH  
# Meter Intervals  
Low Byte  
Reads the low byte of the number of  
meter intervals elapsed.  
_BER_METER_INTERVALS_LOW  
_BER_METER_INTERVALS_HIGH  
# Meter Intervals  
High Byte  
Reads the high byte of the number of  
meter intervals elapsed.  
100251B  
Conexant  
D-5  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix D Release Notes  
Bt8960  
D.1 Memory Requirements  
Software Users Guide  
BER Status Bits  
Status  
Bit  
Indicates  
Value = 0  
Not Active  
Value = 1  
0
BER Meter Enabled  
Reserved  
Active  
17  
D.1.6 Internal BER Meter Operation  
This section describes how to use the Bt8960s Internal BER Meter. The BER Meter can be used to  
verify the integrity of the line. The BER Meter can be used as a diagnostic tool during  
production/field testing or hardware/software development.  
The BER Meter uses its internal scrambled ones generator & de-scrambler to detect bit-errors.  
For the BER Meter to function properly, both the HTU-C and HTU-R must issue the  
_BER_METER_START API command. Since the BER Meter uses its own internal scrambled  
ones generator, the BER Meter can be not used when transporting real payload data. The BER  
Meter is only operational after the bit-pump has successfully completed startup.  
D.1.6.1 BER_METER Compiler Flag  
The BER_METER flag compiles in the BER Meter code. The BER Meter code adds ~400 bytes of  
ROM and 1 byte of RAM plus an additional 5 bytes of RAM for each bit-pump.  
NOTE: The BER_METER flag can not be declared when the INT_BUG compiler flag is  
specified.  
D.1.6.2 BER_METER API Commands  
The BER Meter API commands are discussed in Section 5.  
D.1.6.3 Calculating Avg BER and Elapsed Time  
The following formulas are used to calculate the Avg BER and Elapsed Time.  
#ofBitError s  
AvgBER  
=
#ofMeterInt ervals *MeterInter valLength *2  
= #ofMeterInt ervals *MeterInter valLength *2  
DataRate  
ElapsedTim e  
D-6  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix D Release Notes  
Software Users Guide  
D.1 Memory Requirements  
Variable  
# of Bit-Errors  
How derived  
Read the # of Bit-Errors Low & High Byte API commands and build a 16-bit unsigned integer.  
Read the # of Meter Intervals Low & High Byte API commands and build a 16-bit unsigned integer.  
# of Meter Intervals  
Meter Interval Length  
Read the Bt8960 Meter Interval Register (Address 0x18, 0x19) and build a 16-bit unsigned  
integer. During normal operation, these registers should always read 0x8000 (32768).  
Data Rate  
2
Data Rate of the system, i.e. 288000 or 416000.  
The * 2is necessary since there are 2 bits per symbol and the meter interval length is based on  
the number of symbols.  
NOTE(S): 16-bit value = (high byte << 8) + (low byte)  
Figure D-1. Example  
/*  
* Assuming 288kbps Data Rate, Normal Operation, and BER Meter Active  
* Also assumes using compiler/linker that supports floating point.  
*/  
void get_ber_meter_status (unsigned char no)  
{
unsigned char temp, temp1;  
unsigned int errors, intervals;  
float avg_ber, elapsed_time;  
_BtStatus(no, _BER_METER_STATUS, _BER_BIT_ERRORS_LOW, &temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_BIT_ERRORS_HIGH, &temp1);  
errors = (unsigned)BYTE2WORD(temp1, temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_METER_INTERVALS_LOW, &temp);  
_BtStatus(no, _BER_METER_STATUS, _BER_METER_INTERVALS_HIGH, &temp1)  
intervals = (unsigned)BYTE2WORD(temp1, temp);  
avg_ber = (errors) / (intervals * 0x8000 * 2) /* equations don’t show necessary type casting */  
elapsed_time = (intervals * 0x8000 * 2) / (288000)  
#if TDEBUG  
printf("# Bit Errors = %u\n", errors);  
printf("# Meter Intervals = %u\n", intervals);  
printf("Avg Ber = %.2e\n", avg_ber);  
printf("Elapsed Time = %.1f seconds\n", elapsed_time);  
#endif  
return;  
}
100251_008  
100251B  
Conexant  
D-7  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix D Release Notes  
Bt8960  
D.1 Memory Requirements  
Software Users Guide  
D.1.7 BER Meter Bit-pump Code Implementation  
This section describes how the Bt8960s Internal BER Meter is implemented in the Bit-pump  
Software. The user does not need to be aware of the exact details since all access to the BER Meter  
status is done through the API.  
D.1.7.1 BER_METER_STRUCT Structure  
The user should not directly access the BER Meter structure.  
The BER Meter Structure is defined as follows:  
#ifdef BER_METER  
typedef union  
{
unsigned char reg;  
struct  
{
unsigned char enabled:1;  
unsigned char :7;  
} bits;  
} ber_meter_status;  
typedef struct  
{
ber_meter_status status;  
unsigned int bit_errors;  
unsigned int meter_intervals;  
}BER_METER_STRUCT;  
extern BER_METER_STRUCT idata ber_meter[_NO_OF_LOOPS];  
#endif  
The ber_meter array is stored in idata since it takes up 5 bytes of memory per bit-pump.  
be_meter_status: struct  
The ber_meter_status structure contains 1 field, enabled. The enabled flag is used to determine  
when the BER Meter is currently active. The enabled bit is deactivated whenever the part is reset,  
startup is activated or deactivated, or the _BER_METER_STOP API command is called.  
bit_errors: int  
This variable keeps track of the number of bit errors. This is updated every Meter Interval when  
the BER Meter is enabled. This variable is reset whenever the _BER_METER_START API  
command is called.  
meter_intervals: int  
This variable keeps track of the number of meter intervals elapsed. This is updated every Meter  
Interval when the BER Meter is enabled. This variable is reset whenever the  
_BER_METER_START API command is called.  
D.1.7.2 Interrupt Handler  
The interrupt handler reads the Bit Error Rate Meter Register (Address 0x4C, 0x4D) and updates  
the Number of Bit-Errors and Number of Meter Intervals counter after every meter interval. This  
causes the interrupt handler to be slightly longer, ~55uS per bit-pump on an 11.0592MHz  
Intel 8032.  
D-8  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
Bt8960  
Appendix D Release Notes  
Software Users Guide  
D.2 Bt8960 Bit-pump Version 1.1, Release Notes—September 2, 1996  
D.2Bt8960 Bit-pump Version 1.1, Release NotesSeptember 2, 1996  
D.2.1 PLL Modes CLK_FREQ Bits were Incorrect  
The PLL Frequency #defines for 2 & 8 Channel in API.H (line 116) were incorrect. However, the  
4 and 6 channel #defines were correct. This bug could potentially impact the performance on  
systems running below 220kbps or running above 483kbps since the wrong CLK_FREQ range  
setting was selected. The PLL Modes Register (Addr: 0x22) should be as follows:  
Nominal Crystal Center  
clk_freq[1,0]  
Number of Channels (N)  
Resulting Data Rate  
Freq  
9.216 MHz  
13.312 MHz  
5.120 MHz  
-
00  
01  
10  
11  
4
288 kbps  
416 kbps  
160 kbps  
-
6
2
Reserved  
NOTE(S): The Reservedsetting behaves identically to the 6 Channel setting and not as an 8 Channel setting as initially presumed.  
Brooktree reserves the right to change the definition of the Reservedsetting.  
D.2.2 Added ERLE Support  
The ERLE code is a diagnostic tool to verify the integrity of the hardwares analog front-end and  
echo canceler. The files ERLE.C and ERLE.H contain the ERLE code. These 2 files are located  
in the bit-pump sub-directory. The SCRIPT.BLD file was modified to include the ERLE target.  
Please see the Bt8960 Single-Chip 2B1Q Transceiver Bit-pump Software Users Guide  
Version 1.1 (UG8960-1A) for complete details of the ERLE code.  
D.2.3 Bt8960EVM Single Board Support  
Brooktree now offers a production Bt8960EVM System. These systems have integrated the  
Bt8960 Chip, Microprocessor, EPROM, etc. onto a single PCB. The Bt8960EVM System now has  
separate code and data space unlike previous EVM versions. The following changes were made to  
the bit-pump code to support the new systems:  
D.2.3.1 USER.C - Different Bit-pump Address Mapping  
The bit-pump address map is located at 0x0000, the _BIT_PUMP0_ADD #define was changed to  
reflect the new hardware.  
100251B  
Conexant  
D-9  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix D Release Notes  
Bt8960  
D.2 Bt8960 Bit-pump Version 1.1, Release NotesSeptember 2, 1996  
Software Users Guide  
D.2.3.2 SCRIPT.BLD - XDATA Mapping  
The LFLAGS XDATA() option was changed to 0x0000 to reflect the new hardware. In addition,  
the CFLAGS is compiled with the SINGLE_LOOP bit-pump compiler option since the new  
hardware only supports one bit-pump.  
D.2.3.3 Application Code  
The high-level application code was modified to take advantage of the features of the new system.  
Please see the Bt8960 Single-Chip 2B1Q Transceiver EVM Software Users Guide Version 1.1  
(UG8960-3A) and EVM Hardware Users Guide (UG8960-4A) for complete details on the new  
Bt8960EVMs.=  
D-10  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
E
Appendix E Version 1.1 Release Notes  
Bt8960 Bit-pump Version 1.1, Release Notes, September 2, 1996  
E.1PLL Modes CLK_FREQ Bits were Incorrect  
The PLL Frequency #defines for 2 & 8 Channel in API.H (line 116) were incorrect. However, the  
4 and 6 channel #defines were correct. This bug could potentially impact the performance on  
systems running below 220kbps or running above 483kbps since the wrong CLK_FREQ range  
setting was selected. The PLL Modes Register (Addr: 0x22) should be as follows:  
Nominal Crystal Center  
clk_freq[1,0]  
Number of Channels (N)  
Resulting Data Rate  
Freq  
9.216 MHz  
13.312 MHz  
5.120 MHz  
-
00  
01  
10  
11  
4
288 kbps  
416 kbps  
160 kbps  
-
6
2
Reserved  
NOTE(S): The Reservedsetting behaves identically to the 6 Channel setting and not as an 8 Channel setting as initially presumed.  
Brooktree reserves the right to change the definition of the Reservedsetting.  
100251B  
Conexant  
E-1  
Preliminary Information/Conexant Proprietary and Confidential  
Appendix E Version 1.1 Release Notes  
Bt8960  
E.2 Added ERLE Support  
Software Users Guide  
E.2Added ERLE Support  
The ERLE code is a diagnostic tool to verify the integrity of the hardwares analog front-end and  
echo canceler. The files ERLE.C and ERLE.H contain the ERLE code. These 2 files are located  
in the bit-pump sub-directory. The SCRIPT.BLD file was modified to include the ERLE target.  
Please see the Bt8960 Single-Chip 2B1Q Transceiver Bit-pump Software Users Guide Version  
1.1 (UG8960-1A) for complete details of the ERLE code.  
E.3Bt8960EVM Single Board Support  
Brooktree now offers a production Bt8960EVM System. These systems have integrated the  
Bt8960 Chip, Microprocessor, EPROM, etc. onto a single PCB. The Bt8960EVM System now has  
separate code and data space unlike previous EVM versions. The following changes were made to  
the bit-pump code to support the new systems:  
E.3.1 USER.C - Different Bit-pump Address Mapping  
The bit-pump address map is located at 0x0000, the _BIT_PUMP0_ADD #define was changed to  
reflect the new hardware.  
E.3.2 SCRIPT.BLD - XDATA Mapping  
The LFLAGS XDATA() option was changed to 0x0000 to reflect the new hardware. In addition,  
the CFLAGS is compiled with the SINGLE_LOOP bit-pump compiler option since the new  
hardware only supports one bit-pump.  
E.3.3 Application Code  
The high-level application code was modified to take advantage of the features of the new system.  
Please see the Bt8960 Single-Chip 2B1Q Transceiver EVM Software Users Guide Version 1.1  
(UG8960-3A) and EVM Hardware Users Guide (UG8960-4A) for complete details on the new  
Bt8960EVMs.  
E-2  
Conexant  
100251B  
Preliminary Information/Conexant Proprietary and Confidential  
0.0 Sales Offices  
Further Information  
Europe North – England  
literature@conexant.com  
(800) 854-8099 (North America)  
(949) 483-6996 (International)  
Printed in USA  
Phone: +44 1344 486444  
Fax:  
+44 1344 486555  
Europe – Israel/Greece  
Phone: +972 9 9524000  
Fax:  
+972 9 9573732  
World Headquarters  
Conexant Systems, Inc.  
4311 Jamboree Road  
Newport Beach, CA  
92660-3007  
Europe South – France  
Phone: +33 1 41 44 36 51  
Fax:  
+33 1 41 44 36 90  
Phone: (949) 483-4600  
Fax 1: (949) 483-4078  
Fax 2: (949) 483-4391  
Europe Mediterranean – Italy  
Phone: +39 02 93179911  
Fax:  
+39 02 93179913  
Americas  
Europe – Sweden  
Phone: +46 (0) 8 5091 4319  
U.S. Northwest/  
Pacific Northwest – Santa Clara  
Phone: (408) 249-9696  
Fax:  
+46 (0) 8 590 041 10  
Fax:  
(408) 249-7113  
Europe – Finland  
Phone: +358 (0) 9 85 666 435  
U.S. Southwest – Los Angeles  
Phone: (805) 376-0559  
Fax:  
+358 (0) 9 85 666 220  
Fax:  
(805) 376-8180  
Asia – Pacific  
Taiwan  
U.S. Southwest – Orange County  
Phone: (886-2) 2-720-0282  
Phone: (949) 483-9119  
Fax:  
(886-2) 2-757-6760  
Fax:  
(949) 483-9090  
Australia  
U.S. Southwest – San Diego  
Phone: (61-2) 9869 4088  
Phone: (858) 713-3374  
Fax:  
(61-2) 9869 4077  
Fax:  
(858) 713-4001  
China – Central  
Phone: 86-21-6361-2515  
U.S. North Central – Illinois  
Phone: (630) 773-3454  
Fax:  
86-21-6361-2516  
Fax:  
(630) 773-3907  
China – South  
Phone: (852) 2 827-0181  
U.S. South Central – Texas  
Phone: (972) 733-0723  
Fax:  
(852) 2 827-6488  
Fax:  
(972) 407-0639  
China – South (Satellite)  
Phone: (86) 755-5182495  
U.S. Northeast – Massachusetts  
Phone: (978) 367-3200  
Fax:  
(978) 256-6868  
China – North  
Phone: (86-10) 8529-9777  
U.S. Southeast – North Carolina  
Phone: (919) 858-9110  
Fax:  
(86-10) 8529-9778  
Fax:  
(919) 858-8669  
India  
Phone: (91-11) 692-4789  
U.S. Southeast – Florida/  
South America  
Fax:  
(91-11) 692-4712  
Phone: (727) 799-8406  
Korea  
Fax:  
(727) 799-8306  
Phone: (82-2) 565-2880  
Fax: (82-2) 565-1440  
U.S. Mid-Atlantic – Pennsylvania  
Phone: (215) 244-6784  
Korea (Satellite)  
Phone: (82-53) 745-2880  
Fax:  
(215) 244-9292  
Fax:  
(82-53) 745-1440  
Canada – Ontario  
Phone: (613) 271-2358  
Singapore  
Phone: (65) 737 7355  
Fax:  
(613) 271-2359  
Fax:  
(65) 737 9077  
Europe  
Europe Central – Germany  
Japan  
Phone: +49 89 829-1320  
Phone: (81-3) 5371 1520  
Fax:  
+49 89 834-2734  
Fax:  
(81-3) 5371 1501  
www.conexant.com  

相关型号:

2896270

Connector Accessory, Housing, ROHS COMPLIANT
PHOENIX

2896296

Connector Accessory, Din Rail, ROHS COMPLIANT
PHOENIX

2896319

Barrier Strip Terminal Block
PHOENIX

2896335

Rectangular Power Connector
PHOENIX

2896458

Barrier Strip Terminal Block
PHOENIX

28970-BRF-001-A

AutoBaud Technology
TE

28970-BRF-001-A_15

AutoBaud™Technology
TE

28973-BRF-001-A

High Speed, Low Power Single-Chip
TE

28973-BRF-001-A_15

High Speed, Low Power Single-Chip SDSL/HDSL Transceiver
TE

28973-DSH-001-A

Single-Chip SDSL/HDSL Transceiver
TE

28973-DSH-001-A_15

Single-Chip SDSL/HDSL Transceiver
TE

28973-EVMD-001-A

SDSL/HDSL Transceiver/Framer
TE