2EDL1SC [TE]
Power Entry Module with RFI Power Line Filter for General or Medical Applications; 与一般或医疗应用RFI电源滤波器电源输入模块型号: | 2EDL1SC |
厂家: | TE CONNECTIVITY |
描述: | Power Entry Module with RFI Power Line Filter for General or Medical Applications |
文件: | 总4页 (文件大小:100K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications
L Series
UL Recognized
CSA Certified
VDE Approved
EDL4C/EHL4C
EDL1S/EHL1S
L Series
Voltage Selection
The L series power entry modules are compact units that
combine a multi-function power entry module and high per-
formance RFI filtering capabilities. They are available with
either a four-voltage selector or a DPST on/off switch. Both
variations can be specified with North American or
European fusing capabilities and are available in either
flange or snap-in mounting.
To change selected voltage: disconnect the power cord;
open cover using a small blade screwdriver or similar tool;
insert the tool into the voltage selection slot and remove
wheel from unit; select desired voltage; replace wheel into
unit and close cover, making sure the selected voltage
appears in connector window.
These filters are UL recognized, CSA certified, and VDE
approved. The L series modules offer a choice of filters for
general or medical applications.
Note: All models have North American or dual European fusing capability
and are available in either flange or snap-in mounting.
EDL Models
Voltage
selection
slot
The RFI filter is for general purpose applications where
line-to-line and line-to-ground noise must be controlled.
The filter is designed to meet the very low leakage
requirements of VDE portable equipment. They are
available in three current ratings.
4-Voltage
selection
wheel
Fuseholder
Cover
EHL Models
This medical filter provides susceptibility protection
without the leakage current associated with line-to-ground
capacitors. Designed to allow equipment to meet UL544
for patient care and non-patient care equipment, the EHL
filter has a maximum leakage current of 2 µA at 120 VAC
60 Hz. See Appendix C for more information on medical
applications and UL standards.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
118
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
Germany:
49-89-6089-0
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Specifications
L Series
Electrical Schematics
Maximum leakage current, each line-to-ground:
EDL
Models Models
EHL
DL Models (with switch)
@120 VAC 60 Hz:
@250 VAC 50 Hz:
0.25 mA
0.50 mA
2 µA
5 µA
Cutomer
Note 2
Transformer
Note 1
H
G
On/Off
Primaries
Neutral
Ground
Hipot rating (one minute):
line-to-ground
2
1
(1) (1a)
1500
1450
1500
1450
line-to-line
(2) (2a)
Device
4
3
Hot
Operating frequency:
Operating voltages:
50/60 Hz
1S & 1SC Suffix (fixed):
250 VAC Max.
DL Models (with 4-voltage selection)
Cutomer
Transformer
Primaries
4 & 4C Suffix (selectable): 100, 120, 220, 240 VAC
Rated current:
2EDL & 2EHL
120V
100V
220V
240V
Note 2
A
A
A
2A
4A
6A
20V
Note 1
G
On/Off
Hot
B
C
B
C
B
4EDL & 4EHL
6EL, 6EDL & 6EHL
100V
C
D
Ground
Switch:
Double-insulated, rated
D
E
D
E
for 10,000 operations at full
120V
E
load. 51 Amp inrush capability.
F
F
F
Neutral
H
Fuse (not included):
Terminals:
Accepts one .25" x 1.25" fuse
or two 5 x 20 mm fuses
HL Models (with switch)
Customer
Transformer
Primaries
110 [2.79] except for switch
.187 [4.8] for switch
Note 2
On/Off
Note 1
H
G
Neutral
Ground
Minimum insertion loss in dB:
2
1
(1) (1a)
Line-to-ground in 50 ohm circuit
(2) (2a)
Device
4
3
Current
Rating
Frequency-MHz
Hot
.05
.15
1
5
10
30
EDL Models
2A
6
2
1
14
8
6
24
18
17
40
32
31
45
38
37
50
45
45
4A
6A
HL Models (with 4-voltage selection)
EHL Models
06A
Customer
Transformer
Primaries
3
8
15
18
18
18
120V
100V
220V
240V
Line-to-line in 50 ohm circuit
Note 2
A
A
A
20V
Note 1
G
On/Off
Hot
Current
Rating
Frequency-MHz
B
C
B
C
B
100V
.05
.5
1
3
5
10
30
C
D
Ground
EDL Models
D
E
D
E
2A
4A
6A
7
6
6
16
14
15
21
18
20
23
23
25
37
26
24
47
45
45
50
47
50
120V
E
F
F
F
Neutral
H
EHL Models
06A
4
14
20
28
32
38
42
Note 1:
Note 2:
Provision for dual European style fusing.
On/Off switch present only with "S" suffix.
Resistor location for reference only.
119
Catalog 1654001
Revised 05-07
Dimensions are in inches and
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Germany:
49-89-6089-0
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
L Series
Case Styles — Unfiltered Models
Case Styles — Filtered Models
Flange Models
Flange Models
3
1
4
2
G
H
C D
D
C
F
B
A
Side View
.221
5.61
Side View
E
.221
5.61
E
.06
1.52
R
3
1
4
*
2.201
2
55.91
G
H
*
2.213
56.21
.020
.508
Snap-In Models
R
*
1.122
28.50
1.575
40.00
A
C
E
*
+.008 -.00
+.203 -.00
D
F
B
Back View
G
H
Recommended Panel Cutout
D
C
Typical dimensions:
Mounting Holes: .126 [3.20 ] Dia. (2)
All backplate terminals: .110 [2.79 ] terminals, except for switch.
Switch terminals are .187 [4.765 ] Note: Snap-in models allow front mounting only.
Side View
.221
5.61
E
Snap-In Models
Note: Metric fuse models have additional jumper from filter-to-module.
C D
Case Dimensions
Side View
F
A
A
(max)
B
C
D
E
F
.221
5.61
±.015
±.381
E
Part No.
(max) (max) (max) (max)
.06
1.52
R
Flange
1.98 1.575
2.3
2.14
1.66
1.11
Unfiltered
Snap-in
Unfiltered
50.29 40.0 58.42 54.36 42.16 28.19
A
C
E
*
2.201
1.28
32.51
2.3
58.42 54.36 42.16 28.19
2.3 2.14 2.01 1.11
50.29 40.0 58.42 54.36 51.05 28.19
2.14
1.66
1.11
D
F
B
(1)
(2)
—
55.91
G
H
*
2.213
56.21
.020
.508
R
Flange
Filtered
1.98 1.575
*
1.122
28.50
Snap-in
Filtered
1.28
32.51
2.3
2.14
2.01
1.11
—
*
+.008 -.00
+.203 -.00
58.42 54.36 51.05 28.19
Back View
Recommended Panel Cutout
(1) For panel thickness of .031-.079 [0.8-2.0]
(2) For panel thickness of .083-.126 [2.1-3.2]
(3) For snap-in application, the 1.22 [28.5] sides of the cutout must have a .02 [.508] radius on
the installation side.
All backplate terminals: .110 [2.79] terminals, except for switch. Switch terminals are .187 [4.75]
Note: Snap-in models allow front mounting only.
120
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
reference purposes only.
Specifications subject
to change.
Germany:
49-89-6089-0
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
L Series
UNFILTERED MODELS
Part
Current
Rating
Available Voltage
Selection
DPST
On/Off
Switch
Mounting
Style
Fuseholder
Type
Number
Position
6EL1S
6EL1SC
6EL1SM
6EL1SCM
6EL4
6EL4C
6EL4M
6EL4CM
6A
6A
6A
6A
6A
6A
6A
6A
1
1
1
1
4
4
4
4
••
••
••
••
Flange
Snap-In
Flange
Snap-In
Flange
Snap-In
Flange
Snap-in
North American
North American
Metric
Metric
North American
North American
Metric
Metric
FILTERED MODELS
Part
Filter
Type
Current
Rating
Available Voltage
Selection
DPST
On/Off
Switch
Mounting
Style
Fuseholder
Type
Number
Position
2EDL1S
2EDL1SC
2EDL1SM
2EDL1SCM
2EDL4
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Linear
Medical
Medical
Medical
Medical
Medical
Medical
Medical
Medical
2A
2A
2A
2A
2A
2A
2A
2A
4A
4A
4A
4A
4A
4A
4A
4A
6A
6
6
6
6
6
6
6
6
6
1
1
1
1
4
4
4
4
1
1
1
1
4
4
4
4
1
1
1
1
4
4
4
4
1
1
1
1
4
4
4
4
••
••
••
••
Flange
Snap-In
Flange
Snap-In
Flange
Snap-In
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Flange
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
Flange
Snap-in
North American
North American
Metric
Metric
North American
North American
Metric
2EDL4C
2EDL4M
2EDL4CM
4EDL1S
4EDL1SC
4EDL1SM
4EDL1SCM
4EDL4
Metric
••
••
••
••
North American
North American
Metric
Metric
North American
North American
Metric
4EDL4C
4EDL4M
4EDL4CM
6EDL1S
6EDL1SC
6EDL1SM
6EDL1SCM
6EDL4
Metric
••
••
••
••
North American
North American
Metric
Metric
North American
North American
Metric
6EDL4C
6EDL4M
6EDL4CM
6EHL1S
6EHL1SC
6EHL1SM
6EHL1SCM
6EHL4
6EHL4C
6EHL4M
6EHL4CM
Metric
••
••
••
••
North American
North American
Metric
6
6
6
6
6
6
Metric
North American
North American
Metric
Metric
• Includes DPST switch
121
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
Germany:
49-89-6089-0
相关型号:
©2020 ICPDF网 联系我们和版权申明