Instruction Sheet  
Terminating Head 58247-1  
For MTA-156 Receptacle Connectors  
Using Discrete Wire  
408-6930  
19 APR 11 Rev F  
Locating  
Pawl  
Wire  
Inserter  
Mass Termination Assembly (MTA) -156  
Insulation Displacement Contact (IDC)  
Closed -End Receptacle Connectors  
Feed  
Slide  
Tool  
Base  
With Lock Without Lock With Lock,  
Without Lock,  
(Ramp)  
(Ramp)  
With Polarizing With Polarizing  
Tabs Tabs  
Adjuster  
(Insertion Rod)  
Figure 1  
Wire Inserter — forces the wire into the two slotted  
beams of the contact. Note that it provides support for  
the contact beams when applying insertion force on  
the wire.  
1. INTRODUCTION  
Terminating Head 58247--1 (shown in Figure 1) is  
designed to terminate discrete wire in MTA--156 IDC  
closed--end receptacle connectors with or without lock  
(ramp) and with or without polarizing tabs. Slotted  
contacts for insulation displacement termination are  
pre--assembled on 3.96--mm [.156--in.] centerlines in  
each color--coded housing for a specific wire size.  
Adjuster (Insertion Rod) — is a piston for the wire  
inserter and regulates wire inserter travel.  
Feed Slide — automatically positions the connector  
after each termination.  
Locating Pawl (or Anti--Backup Pawl) — aligns the  
connector for insertion, and retains it during  
termination.  
The head must be installed in Pistol Grip Manual  
Handle Assembly 58074--1 or Pistol Grip Pneumatic  
Handle Assembly 58075--1. For head installation and  
removal, refer to Instruction Sheet 408--6790 for the  
manual handle assembly and 408--6789 for the  
pneumatic handle assembly.  
3. SETUP AND TEST INSPECTION  
The adjuster (insertion rod) is preset for wire sizes  
26 through 18 AWG. If the wire is being inserted too  
deeply or not deeply enough inside the contact, it may  
be necessary to adjust the depth of the wire inserter  
or, in addition, if the pneumatic handle assembly is  
being used, it may be necessary to adjust the air  
pressure. Proceed as follows:  
For detailed connector description and application  
requirements, refer to Application Specification  
114--1020.  
Read these and all referenced instructions thoroughly  
before using the head.  
3.1. Setup  
All numerical values in this instruction sheet are  
in metric units [with U.S. customary units in  
brackets]. Dimensions are in millimeters [and  
inches]. Figures are not drawn to scale.  
NOTE  
1. Determine the wire size, and select the  
appropriate color--coded connector from Figure 2.  
i
WIRE SIZE (AWG)  
CONNECTOR COLOR CODE  
Reasons for reissue of this instruction sheet are  
provided in Section 8, REVISION SUMMARY.  
26  
24  
22  
20  
18  
Blue  
Natural  
Red  
2. DESCRIPTION  
Yellow  
Orange  
The head serves as a guide and support for the  
connector during termination. Features of the head  
(shown in Figure 1) and their function are as follows.  
Figure 2  
E2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company  
All Rights Reserved  
*Trademark  
TOOLING ASSISTANCE CENTER 1--800--722--1111 This controlled document is subject to change.  
1 of 5  
PRODUCT INFORMATION 1--800--522--6752  
For latest revision and Regional Customer Service,  
visit our website at www.te.com  
LOC B  
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.  
408-6930  
2. Using a small knife, cut off the wire retainers  
(strain relief) of the connector. This will provide a  
clear view for inspecting the connector for a  
properly terminated wire in the contact. See  
Figure 3.  
For the pneumatic handle assembly, if the wire is  
inserted too deeply (more than the required wire  
insertion depth), refer to Section 4, WIRE  
INSERTION DEPTH ADJUSTMENT. If the wire is  
not inserted deeply enough (less than the required  
wire insertion depth), increase the air pressure by  
69 kPa [10 psi]. Repeat the termination procedure  
and check the insertion depth. Continue in this  
manner until either the proper insertion depth is  
obtained or the air pressure is set to 483 kPa  
[70 psi]. If the proper insertion depth is NOT  
reached at 483 kPa [70 psi], return the air pressure  
to 276 kPa [40 psi], and refer to Section 4.  
Wire retainers are removed in a connector for  
testing only. DO NOT use such connectors for  
production application.  
CAUTION  
!
3. Make a test termination according to Steps 1  
through 5 of Section 5, TERMINATING  
PROCEDURE.  
6. Inspect the termination according to  
Paragraph 3.2.  
4. Push the connector out of the right side of the  
head.  
5. Check that the wire insertion depth is within the  
dimension given in Figure 3.  
3.2. Termination Inspection (Refer to Figure 3)  
Refer to 114 -1020 for detailed explanation of the  
termination inspection requirements.  
NOTE  
To obtain the wire insertion depth, measure from  
the front of the contact beam to the center of the  
wire as shown in Figure 3 - or - measure from  
the front of the contact beam to the back of the  
wire and subtract the wire diameter divided by 2.  
NOTE  
i
i
1 — The required wire insertion depth is within the  
dimension given in Figure 3 (refer to Step 5 of  
Paragraph 3.1 for measurement).  
If it is not, proceed as follows:  
For the manual handle assembly, refer to  
Section 4, WIRE INSERTION DEPTH  
ADJUSTMENT.  
2 — The end of the wire extends past the contact  
beam by at least 1.52 mm [.060 in.].  
Termination Inspection  
Test Connector  
Production Connector  
Contact (Partially  
Removed)  
5
Wire  
Wire Extends Past Wire  
Retainer (Strain Relief)  
Wire Insulation  
Not Nicked or Cut  
4
Lock  
(Ramp, Ref)  
Wire Retainer  
(Strain Relief)  
Removed  
1
2
3
Contact Beams  
Not Deformed  
2.41+0.46/ -0.13 mm [.095+.018/ -.005 in.]  
Wire Insertion Depth  
(Front of Contact Beam to Center of Wire)  
1.52 mm [.060 in.] Min  
End of Wire Extends Past  
Contact Beam  
Figure 3  
2 of 5  
Rev F  
408-6930  
5. TERMINATING PROCEDURE (Refer to Figure 5)  
3 — The contact beams are NOT deformed. If  
damage is apparent, replace the contacts in  
accordance with the instructions packaged with the  
connector.  
There is no wire preparation required.  
NOTE  
i
4 — The wire insulation is NOT nicked or cut in  
any area other than the two contact slots.  
1. Insert the connector into the left side of the  
head.  
5 — The wire extends past the wire retainer (strain  
relief) of the connector.  
2. Align the contact to be terminated with the wire  
inserter of the head (shown in Figure 1). Make sure  
that the locating pawl rests between the connector  
index ribs.  
4. WIRE INSERTION DEPTH ADJUSTMENT (See Figure 4)  
1. Remove the head from the handle assembly.  
3. Insert an unstripped wire into the funnel area  
between the contact and the wire inserter until it  
bottoms on the tool base.  
2. If the wire is inserted too deeply (more than the  
required wire insertion depth), reduce the wire  
insertion depth by turning the adjuster 1/6 of a  
revolution clockwise. The wire insertion depth will  
be reduced by approximately 0.20 mm [.008 in.].  
4. Squeeze the cam handle (manual) or depress  
the trigger (pneumatic) of the handle assembly,  
and hold it until the ratchet releases (manual) or  
the wire inserter bottoms (pneumatic).  
If the wire is bottomed in the contact slot, this  
indicates that the adjuster is set to the maximum  
wire insertion depth — DO NOT turn the adjuster  
counterclockwise; otherwise damage to the head  
may occur.  
CAUTION  
5. Release the cam handle or trigger. The wire  
inserter will retract and the feed slide will  
automatically advance the connector to the next  
contact position.  
!
If the wire is not inserted deeply enough (less than  
the required wire insertion depth), increase the wire  
insertion depth by turning the adjuster 1/6 of a  
revolution counterclockwise. The wire insertion  
depth will be increased by approximately 0.20 mm  
[.008 in.].  
The locating pawl will move up and down as the  
connector is automatically advanced through the  
head. However, if movement is obstructed, or if  
desired, the locating pawl can be depressed and  
the connector moved manually out of the RIGHT  
side of the head.  
NOTE  
i
6. Repeat Steps 2 through 5 until all contacts have  
been terminated.  
When turning the adjuster counterclockwise,  
make sure to check the wire insertion depth after  
EACH 1/6 revolution. If the adjuster is set past the  
maximum setting, damage to the head may  
occur.  
CAUTION  
7. Inspect each termination according to  
Paragraph 3.2.  
!
6. MAINTENANCE AND INSPECTION  
6.1. Daily Maintenance  
Wire Insertion Depth Adjustment  
1. Remove dust, moisture, and other contaminants  
with a clean, soft brush or lint--free cloth. DO NOT  
use objects that could damage the head.  
LOCKWISE to  
Wire Insertion Depth  
2. Make sure that all components are in place and  
properly secured.  
3. Actuate the tool to make sure that the  
mechanisms inside the head function smoothly.  
Adjuster  
6.2. Periodic Maintenance  
Turn COUNTERCLOCKWISE to  
Increase Wire Insertion Depth  
DO NOT Turn Past Maximum Setting  
Refer to CAUTION  
1. Remove any accumulated film with a suitable  
cleaning agent that will not affect plastic.  
2. Make sure all components are in place and  
properly secured.  
Note: 1/6 Revolution Equals 0.20 mm [.008 in.] Adjustment  
3. Check for chipped, cracked, worn, or broken  
areas on the head. If damage is evident, repair or  
replace the head.  
Figure 4  
Rev F  
3 of 5  
408-6930  
Locating  
Pawl  
Wire  
Feed Slide  
Funnel Area  
Index Rib of  
Connector  
Pistol Grip Handle  
Assembly (Manual Shown)  
Tool Base  
Left Side  
of Head  
Figure 5  
quality and reliability. Order replacement parts  
through your representative, or call 1--800--526--5142,  
or send a facsimile of your purchase order to  
717--986--7605, or write to:  
6.3. Inspection  
Regular inspections should be performed by quality  
control personnel with a record of quality control  
inspections remaining with the personnel responsible  
for the head. One inspection per month is the  
recommended frequency; however, operator training  
and skill, amount of use, working conditions, and  
established company standards are all factors to be  
considered in establishing inspection frequency.  
CUSTOMER SERVICE (038--035)  
TYCO ELECTRONICS CORPORATION  
PO BOX 3608  
HARRISBURG PA 17105--3608  
For customer repair service, call 1--800--526--5136.  
7. REPLACEMENT AND REPAIR  
8. REVISION SUMMARY  
Customer--replaceable parts are listed in Figure 6.  
A complete inventory should be stocked and  
controlled to prevent lost time when replacement of  
parts is necessary. Parts other than those listed  
should be replaced by TE Connectivity to ensure  
Revisions to this instruction sheet include:  
S Updated document to corporate requirements  
S New logo  
4 of 5  
Rev F  
408-6930  
88.9 mm [3.50 in.]  
A
A
25.4 mm  
[1.00 in.]  
5
Section A -A  
1
2
8
6
7
4
3
10  
11  
9
28.58 mm  
[1.125 in.]  
12  
15  
13  
Weight: 85 g [3 oz]  
14  
REPLACEMENT PARTS  
DESCRIPTION  
ITEM  
1
PART NUMBER  
312150--1  
312138--3  
6--22278--5  
312147--1  
4--22430--8  
21041--7  
QTY PER HEAD  
HEAD, Finished  
HOUSING, Insert  
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
2
3
SPRING, Compression  
PAWL, Locating  
4
5
SCREW, Machine (4--40¢.875 in. L)  
PIN, Spiral Spring  
6
7
312192--1  
312154--1  
22488--5  
PAWL, Feed  
8
INSERTER, Wire  
9
SPRING, Compression  
ADJUSTER, Rod Insertion  
ROD, Inserter  
10  
11  
12  
13  
14  
15  
312149--1  
312148--1  
3--21028--2  
312153--1  
1--23147--2  
312151--1  
PIN, Slotted Spring  
CAM, Traverse Slide  
SPRING, Compression  
SLIDE, Feed  
Figure 6  
Rev F  
5 of 5  

相关型号:

312153-1

Read these and all referenced instructions thoroughly before using the head.
TE

312153-1

Terminating Head 58247- 1 For MTA- 156 Receptacle Connectors Using Discrete Wire
MACOM

312154--1

Feed- Through Head Assembly
MACOM

312154-1

Read these and all referenced instructions thoroughly before using the head.
TE

312154-1

Terminating Head 58247- 1 For MTA- 156 Receptacle Connectors Using Discrete Wire
MACOM

312156-1

Pistol Grip Pneumatic Handle Assembly
TE

312157-1

Pistol Grip Pneumatic Handle Assembly
TE

312158-2

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
TE

312159-1

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
TE

312160-1

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
TE

312160-1

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
MACOM

312161-1

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
TE