TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
TMP10x Temperature Sensor With I2C and SMBus Interface with  
Alert Function in SOT-23 Package  
1 Features  
3 Description  
The TMP100 and TMP101 devices are digital  
1
Digital Output: SMBus™, Two-Wire, and I2C  
Interface Compatibility  
temperature sensors ideal for negative temperature  
coefficient (NTC) and positive temperature coefficient  
(PTC) thermistor replacement. The devices offer a  
typical accuracy of ±1°C without requiring calibration  
or external component signal conditioning. Device  
temperature sensors are highly linear and do not  
require complex calculations or look-up tables to  
derive the temperature. The on-chip, 12-bit ADC  
offers resolutions down to 0.0625°C. The devices are  
available in 6-Pin SOT-23 packages.  
Resolution: 9 to 12 Bits, User-Selectable  
Accuracy:  
±1°C (Typical) from –55°C to 125°C  
±2°C (Maximum) from –55°C to 125°C  
Low Quiescent Current: 45-μA, 0.1-μA Standby  
Wide Supply Range: 2.7 V to 5.5 V  
TMP100 Features Two Address Pins  
The TMP100 and TMP101 devices feature SMBus,  
Two-Wire, and I2C interface compatibility. The  
TMP100 device allows up to eight devices on one  
bus. The TMP101 device offers an SMBus Alert  
function with up to three devices per bus.  
TMP101 Features One Address Pin and an  
ALERT Pin  
6-Pin SOT-23 Package  
2 Applications  
The TMP100 and TMP101 devices are ideal for  
extended temperature measurement in a variety of  
communication, computer, consumer, environmental,  
industrial, and instrumentation applications.  
Power-Supply Temperature Monitoring  
Computer Peripheral Thermal Protection  
Notebook Computers  
The TMP100 and TMP101 devices are specified for  
operation over a temperature range of 55°C to  
125°C.  
Cell Phones  
Battery Management  
Office Machines  
Device Information(1)  
Thermostat Controls  
Environmental Monitoring and HVAC  
Electromechanical Device Temperature  
PART NUMBER  
TMP100  
PACKAGE  
SOT-23 (6)  
SOT-23 (6)  
BODY SIZE (NOM)  
2.90 mm × 1.60 mm  
2.90 mm × 1.60 mm  
TMP101  
(1) For all available packages, see the orderable addendum at  
the end of the data sheet.  
Simplified Schematics  
Temperature  
Temperature  
Diode  
Diode  
Temp.  
Sensor  
1
2
3
Control  
Logic  
6
5
4
1
2
3
Control  
Logic  
6
5
4
Temp.  
SCL  
SDA  
ADD0  
V+  
SCL  
SDA  
ADD0  
V+  
Sensor  
Σ  
ADC  
Σ  
ADC  
Serial  
Serial  
GND  
GND  
Interface  
Interface  
Converter  
Converter  
Config  
and Temp  
Register  
Config  
and Temp  
Register  
ADD1  
ALERT  
OSC  
OSC  
TMP100  
TMP101  
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,  
intellectual property matters and other important disclaimers. PRODUCTION DATA.  
 
 
 
 
 
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
Table of Contents  
7.3 Feature Description................................................... 9  
7.4 Device Functional Modes........................................ 14  
7.5 Programming........................................................... 15  
Application and Implementation ........................ 19  
8.1 Application Information............................................ 19  
8.2 Typical Application .................................................. 19  
Power Supply Recommendations...................... 21  
1
2
3
4
5
6
Features.................................................................. 1  
Applications ........................................................... 1  
Description ............................................................. 1  
Revision History..................................................... 2  
Pin Configuration and Functions......................... 3  
Specifications......................................................... 4  
6.1 Absolute Maximum Ratings ...................................... 4  
6.2 ESD Ratings ............................................................ 4  
6.3 Recommended Operating Conditions....................... 4  
6.4 Thermal Information ................................................. 4  
6.5 Electrical Characteristics........................................... 5  
6.6 Timing Requirements................................................ 6  
6.7 Typical Characteristics.............................................. 7  
Detailed Description .............................................. 8  
7.1 Overview ................................................................... 8  
7.2 Functional Block Diagram ......................................... 8  
8
9
10 Layout................................................................... 21  
10.1 Layout Guidelines ................................................. 21  
10.2 Layout Examples................................................... 21  
11 Device and Documentation Support ................. 23  
11.1 Related Links ........................................................ 23  
11.2 Trademarks........................................................... 23  
11.3 Electrostatic Discharge Caution............................ 23  
11.4 Glossary................................................................ 23  
7
12 Mechanical, Packaging, and Orderable  
Information ........................................................... 23  
4 Revision History  
Changes from Revision H (March 2015) to Revision I  
Page  
Changed body size values in Device Information table ........................................................................................................ 1  
Changes from Revision G (November 2007) to Revision H  
Page  
Added ESD Ratings table, Feature Description section, Device Functional Modes, Application and Implementation  
section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and  
Mechanical, Packaging, and Orderable Information section. ................................................................................................ 1  
Changed specification values in Timing Requirements table ................................................................................................ 6  
2
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
5 Pin Configuration and Functions  
DBV Package  
6-Pin SOT-23  
Top View  
1
2
3
SCL  
6
5
4
SDA  
ADD0  
V+  
GND  
ADD1  
TMP100  
DBV Package  
6-Pin SOT-23  
Top View  
1
6
SCL  
GND  
SDA  
ADD0  
V+  
2
3
5
4
ALERT  
TMP101  
Pin Functions  
PIN  
NO.  
I/O  
DESCRIPTION  
NAME  
ADD0  
TMP100  
TMP101  
5
3
5
3
I
I
Address select. Connect to GND, V+, or leave floating.  
Address select. Connect to GND, V+, or leave floating.  
Overtemperature alert. Open-drain output; requires a pullup resistor.  
Ground  
ADD1  
ALERT  
GND  
SCL  
2
O
I
2
1
1
Serial clock. Open-drain output; requires a pullup resistor.  
Serial data. Open-drain output; requires a pullup resistor.  
Supply voltage, 2.7 V to 5.5 V  
SDA  
V+  
6
6
I/O  
I
4
4
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
3
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
6 Specifications  
6.1 Absolute Maximum Ratings  
over operating free-air temperature range (unless otherwise noted)(1)  
MIN  
MAX  
7.5  
UNIT  
V
Power supply, V+  
Input voltage(2)  
–0.5  
–55  
7.5  
V
Operating temperature  
Junction temperature, TJ  
Storage temperature, Tstg  
125  
150  
150  
°C  
°C  
°C  
–60  
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings  
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended  
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
(2) Input voltage rating applies to all TMP100 and TMP101 input voltages.  
6.2 ESD Ratings  
VALUE  
±2000  
±200  
UNIT  
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)  
Charged device model (CDM), per JEDEC specification JESD22-C101(2)  
V(ESD)  
Electrostatic discharge  
V
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.  
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.  
6.3 Recommended Operating Conditions  
over operating free-air temperature range (unless otherwise noted)  
MIN  
2.7  
NOM  
MAX  
5.5  
UNIT  
V
Supply voltage  
Operating free-air temperature, TA  
–55  
125  
°C  
6.4 Thermal Information  
TMP100, TMP101  
THERMAL METRIC(1)  
DBV (SOT-23)  
6 PINS  
182.9  
UNIT  
RθJA  
RθJC(top)  
RθJB  
ψJT  
Junction-to-ambient thermal resistance  
Junction-to-case (top) thermal resistance  
°C/W  
°C/W  
°C/W  
°C/W  
°C/W  
115  
Junction-to-board thermal resistance  
30.2  
Junction-to-top characterization parameter  
Junction-to-board characterization parameter  
17.1  
ψJB  
29.7  
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.  
4
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
6.5 Electrical Characteristics  
At TA = 55°C to 125°C and V+ = 2.7 V to 5.5 V, unless otherwise noted.  
PARAMETER  
TEST CONDITIONS  
MIN  
TYP  
MAX  
UNIT  
TEMPERATURE INPUT  
Range  
–55  
125  
±2  
°C  
°C  
25°C to 85°C  
55°C to 125°C  
±0.5  
±1  
Accuracy (temperature error)  
±2  
Accuracy (temperature error) vs supply  
Resolution  
0.2  
±0.5  
°C/V  
°C  
Selectable  
0.0625  
DIGITAL INPUT/OUTPUT  
Input capacitance  
3
pF  
V
VIH  
VIL  
IIN  
High-level input logic  
Low-level input logic  
Input current  
0.7 (V+)  
6
0.3 (V+)  
1
0.5  
V
0 V VIN 6 V  
IOL = 3 mA  
IOL = 4 mA  
Selectable  
9 bits  
µA  
V
VOL  
VOL  
Low-level output logic SDA  
Low-level output logic ALERT  
Resolution  
0
0
9
0.15  
0.15  
0.4  
0.4  
V
12  
Bits  
40  
80  
160  
320  
25  
12  
6
75  
10 bits  
150  
300  
600  
Conversion time  
Conversion rate  
ms  
s/s  
11 bits  
12 bits  
9 bits  
10 bits  
11 bits  
12 bits  
3
POWER SUPPLY  
Operating range  
2.7  
5.5  
75  
V
Serial bus inactive  
45  
70  
IQ  
Quiescent current  
Shutdown current  
Serial bus active, SCL frequency = 400 kHz  
Serial bus active, SCL frequency = 3.4 MHz  
Serial bus inactive  
µA  
150  
0.1  
20  
13  
ISD  
Serial bus active, SCL frequency = 400 kHz  
Serial bus active, SCL frequency = 3.4 MHz  
µA  
100  
TEMPERATURE RANGE  
Specified range  
–55  
–60  
125  
150  
°C  
°C  
Storage range  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
5
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
UNIT  
6.6 Timing Requirements  
FAST MODE  
MIN  
HIGH-SPEED MODE  
PARAMETER  
MAX  
MIN  
MAX  
f(SCL)  
t(BUF)  
SCL operating frequency  
0.4  
2
MHz  
ns  
Bus free time between STOP and START condition  
1300  
600  
160  
160  
Hold time after repeated START condition.  
After this period, the first clock is generated.  
t(HDSTA)  
ns  
t(SUSTA)  
t(SUSTO)  
t(HDDAT)  
t(SUDAT)  
t(LOW)  
Repeated START condition setup time  
STOP condition setup time  
Data hold time  
600  
600  
20  
160  
160  
20  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
900  
170  
Data setup time  
100  
1300  
600  
20  
SCL clock LOW period  
SCL clock HIGH period  
Clock rise and fall time  
Data rise and fall time  
360  
60  
t(HIGH)  
tRC, tFC  
tRD, tFD  
300  
300  
40  
170  
6
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
6.7 Typical Characteristics  
At TA = 25°C and V+ = 5 V, unless otherwise noted.  
70  
1
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
60  
V+ = 5 V  
50  
V+ = 27 V  
40  
Serial Bus Inactive  
30  
0.1  
40  
60  
40 20  
60  
20  
0
20 40  
60  
80 100 120 140  
0
20  
40  
60  
80 100 120 140  
Temperature (°C)  
Temperature (°C)  
Figure 1. Quiescent Current vs Temperature  
Figure 2. Shutdown Current vs Temperature  
2.0  
1.5  
1.0  
0.5  
0.0  
400  
350  
300  
250  
V+ = 5 V  
0.5  
1.0  
1.5  
2.0  
V+ = 2.7 V  
NOTE: 12−bit resolution.  
NOTE: 12−bit resolution.  
3 Typical Units  
60  
40  
20  
60  
40 20  
0
20  
40  
60  
80 100 120 140  
0
20  
40  
60  
80 100 120 140  
Temperature (°C)  
Temperature (°C)  
Figure 3. Conversion Time vs Temperature  
Figure 4. Temperature Accuracy vs Temperature  
180  
160  
140  
120  
125°C  
25°C  
100  
125°C  
80  
60  
40  
25°C  
55°C  
55°C  
20  
FAST MODE  
Hs MODE  
0
10k  
100k  
1M  
10M  
SCL Frequency (Hz)  
Figure 5. Quiescent Current With Bus Activity vs Temperature  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
7
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
7 Detailed Description  
7.1 Overview  
The TMP100 and TMP101 devices are digital temperature sensors optimal for thermal management and thermal  
protection applications. The TMP100 and TMP101 devices are Two-Wire, SMBus, and I2C interface-compatible.  
These devices are specified over a operating temperature range of 55°C to 125°C. The Functional Block  
Diagram section shows the internal block diagrams of the TMP100 and TMP101 devices.  
The temperature sensor in the TMP100 and TMP101 devices is the chip itself. Thermal paths run through the  
package leads as well as the plastic package. The package leads provide the primary thermal path because of  
the lower thermal resistance of the metal. The GND pin of the TMP100 or TMP101 is directly connected to the  
metal lead frame, and is the best choice for thermal input.  
7.2 Functional Block Diagram  
Temperature  
SCL  
Temperature  
SCL  
Diode  
Temp.  
Sensor  
Diode  
Temp.  
Sensor  
1
2
3
Control  
Logic  
6
5
4
1
2
3
Control  
Logic  
6
5
4
SDA  
ADD0  
V+  
SDA  
ADD0  
V+  
Σ  
ADC  
Σ  
ADC  
Serial  
Serial  
GND  
GND  
Interface  
Interface  
Converter  
Converter  
Config  
and Temp  
Register  
Config  
and Temp  
Register  
ADD1  
ALERT  
OSC  
OSC  
TMP100  
TMP101  
8
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
7.3 Feature Description  
7.3.1 Digital Temperature Output  
The digital output from each temperature measurement conversion is stored in the read-only Temperature  
Register. The Temperature Register of the TMP100 or TMP101 device is a 12-bit, read-only register that stores  
the output of the most recent conversion. Two bytes must be read to obtain data and are listed in Table 6 and  
Table 7. The first 12 bits are used to indicate temperature with all the remaining bits equal to zero. The data  
format for temperature is listed in Table 1. Negative numbers are represented in binary twos complement format.  
Following power-up or reset, the temperature register reads 0°C until the first conversion is complete.  
The user can obtain 9, 10, 11, or 12 bits of resolution by addressing the Configuration Register and setting the  
resolution bits accordingly. For 9-, 10-, or 11-bit resolution, the most significant bits (MSBs) in the Temperature  
Register are used with the unused least significant bits (LSBs) set to zero.  
Table 1. Temperature Data Format  
DIGITAL OUTPUT  
TEMPERATURE  
(°C)  
BINARY  
HEX  
7FF  
7FF  
640  
500  
4B0  
320  
190  
004  
000  
FFC  
E70  
C90  
800  
128  
127.9375  
100  
80  
0111 1111 1111  
0111 1111 1111  
0110 0100 0000  
0101 0000 0000  
0100 1011 0000  
0011 0010 0000  
0001 1001 0000  
0000 0000 0100  
0000 0000 0000  
1111 1111 1100  
1110 0111 0000  
1100 1001 0000  
1000 0000 0000  
75  
50  
25  
0.25  
0
–0.25  
–25  
–55  
–128  
7.3.2 Serial Interface  
The TMP100 and TMP101 devices operate only as slave devices on the SMBus, Two-Wire, and I2C interface-  
compatible bus. Connections to the bus are made through the open-drain I/O lines SDA and SCL. The TMP100  
and TMP101 devices support the transmission protocol for fast (up to 400 kHz) and high-speed (up to 2 MHz)  
modes. All data bytes are transmitted MSB first.  
7.3.2.1 Bus Overview  
The device that initiates the transfer is called a master, and the devices controlled by the master are slaves. The  
bus must be controlled by a master device that generates the serial clock (SCL), controls the bus access, and  
generates the START and STOP conditions.  
To address a specific device, a START condition is initiated, indicated by pulling the data line (SDA) from a HIGH  
to LOW logic level while SCL is HIGH. All slaves on the bus shift in the slave address byte, with the last bit  
indicating whether a read or write operation is intended. During the ninth clock pulse, the slave being addressed  
responds to the master by generating an Acknowledge and pulling SDA LOW.  
Data transfer is then initiated and sent over eight clock pulses followed by an Acknowledge Bit. During data  
transfer, SDA must remain stable while SCL is HIGH because any change in SDA while SCL is HIGH is  
interpreted as a control signal.  
When all data are transferred, the master generates a STOP condition indicated by pulling SDA from LOW to  
HIGH, while SCL is HIGH.  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
9
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
7.3.2.2 Serial Bus Address  
To program the TMP100 and TMP101 devices, the master must first address slave devices through a slave  
address byte. The slave address byte consists of seven address bits and a direction bit indicating the intent of  
executing a read or write operation.  
The TMP100 device features two address pins to allow up to eight devices to be addressed on a single I2C  
interface. Table 2 describes the pin logic levels used to properly connect up to eight devices. Float indicates the  
pin is left unconnected. The state of pins ADD0 and ADD1 is sampled on the first I2C bus communication and  
must be set before any activity on the interface.  
Table 2. Address Pins and Slave Addresses for the TMP100  
ADD1  
ADD0  
SLAVE ADDRESS  
1001000  
0
0
0
0
Float  
1001001  
1
1001010  
1
0
Float  
1
1001100  
1
1001101  
1
1001110  
Float  
Float  
0
1001011  
1
1001111  
The TMP101 device features one address pin and an ALERT pin, allowing up to three devices to be connected  
per bus. Pin logic levels are described in Table 3. The address pins of the TMP100 and TMP101 devices are  
read after reset or in response to an I2C address acquire request. Following reading, the state of the address  
pins is latched to minimize power dissipation associated with detection.  
Table 3. Address Pins and Slave Addresses for the TMP101  
ADD0  
0
SLAVE ADDRESS  
1001000  
Float  
1
1001001  
1001010  
7.3.2.3 Writing and Reading to the TMP100 and TMP101  
Accessing a particular register on the TMP100 and TMP101 devices is accomplished by writing the appropriate  
value to the Pointer Register. The value for the Pointer Register is the first byte transferred after the I2C slave  
address byte with the R/W bit LOW. Every write operation to the TMP100 and TMP101 devices requires a value  
for the Pointer Register (see Figure 7).  
When reading from the TMP100 and TMP101 devices, the last value stored in the Pointer Register by a write  
operation is used to determine which register is read by a read operation. To change the register pointer for a  
read operation, a new value must be written to the Pointer Register. This action is accomplished by issuing an  
I2C slave address byte with the R/W bit LOW, followed by the Pointer Register Byte. No additional data are  
required. The master can then generate a START condition and send the I2C slave address byte with the R/W bit  
HIGH to initiate the read command; see Figure 8 for details of this sequence. If repeated reads from the same  
register are desired, the Pointer Register bytes do not have to be continually sent because the TMP100 and  
TMP101 devices remember the Pointer Register value until that value is changed by the next write operation.  
10  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
7.3.2.4 Slave Mode Operations  
The TMP100 and TMP101 devices can operate as a slave receiver or slave transmitter.  
7.3.2.4.1 Slave Receiver Mode  
The first byte transmitted by the master is the slave address, with the R/W bit LOW. The TMP100 or TMP101  
devices then acknowledges reception of a valid address. The next byte transmitted by the master is the Pointer  
Register. The TMP100 or TMP101 devices then acknowledges reception of the Pointer Register byte. The next  
byte or bytes are written to the register addressed by the Pointer Register. The TMP100 and TMP101 devices  
acknowledge reception of each data byte. The master can terminate data transfer by generating a START or  
STOP condition.  
7.3.2.4.2 Slave Transmitter Mode  
The first byte is transmitted by the master and is the slave address, with the R/W bit HIGH. The slave  
acknowledges reception of a valid slave address. The next byte is transmitted by the slave and is the most  
significant byte of the register indicated by the Pointer Register. The master acknowledges reception of the data  
byte. The next byte transmitted by the slave is the least significant byte. The master acknowledges reception of  
the data byte. The master can terminate data transfer by generating a Not-Acknowledge on reception of any data  
byte, or generating a START or STOP condition.  
7.3.2.5 SMBus Alert Function  
The TMP101 device supports the SMBus Alert function. When the TMP101 device is operating in Interrupt Mode  
(TM = 1), the ALERT pin of the TMP101 device can be connected as an SMBus Alert signal. When a master  
senses that an ALERT condition is present on the ALERT line, the master sends an SMBus Alert command  
(00011001) on the bus. If the ALERT pin of the TMP101 device is active, the TMP101 device acknowledges the  
SMBus Alert command and responds by returning its slave address on the SDA line. The eighth bit (LSB) of the  
slave address byte indicates if the temperature exceeding THIGH or falling below TLOW caused the ALERT  
condition. For POL = 0, this bit is LOW if the temperature is greater than or equal to THIGH. This bit is HIGH if  
the temperature is less than TLOW. The polarity of this bit is inverted if POL = 1; see Figure 9 for details of this  
sequence.  
If multiple devices on the bus respond to the SMBus Alert command, arbitration during the slave address portion  
of the SMBus alert command determine which device clears its ALERT status. If the TMP101 device wins the  
arbitration, its ALERT pin becomes inactive at the completion of the SMBus Alert command. If the TMP101 loses  
the arbitration, its ALERT pin remains active.  
The TMP100 device also responds to the SMBus ALERT command if its TM bit is set to 1. Because the device  
does not have an ALERT pin, the device must periodically poll the device by issuing an SMBus Alert command.  
If the TMP100 device generates an ALERT, the device acknowledges the SMBus Alert command and returns its  
slave address in the next byte.  
7.3.2.6 General Call  
The TMP100 and TMP101 devices respond to the I2C General Call address (0000000) if the eighth bit is 0. The  
device acknowledges the General Call address and responds to commands in the second byte. If the second  
byte is 00000100, the TMP100 and TMP101 devices latch the status of their address pins, but do not reset. If the  
second byte is 00000110, the TMP100 and TMP101 devices latch the status of their address pins and reset their  
internal registers.  
7.3.2.7 High-Speed Mode  
In order for the I2C bus to operate at frequencies above 400 kHz, the master device must issue an Hs-mode  
master code (00001XXX) as the first byte after a START condition to switch the bus to high-speed operation.  
The TMP100 and TMP101 devices do not acknowledge this byte as required by the I2C specification, but do  
switch their input filters on SDA and SCL and their output filters on SDA to operate in Hs-mode, allowing  
transfers at up to 2 MHz. After the Hs-mode master code is issued, the master transmits an I2C slave address to  
initiate a data transfer operation. The bus continues to operate in Hs-mode until a STOP condition occurs on the  
bus. Upon receiving the STOP condition, the TMP100 and TMP101 devices switch the input and output filter  
back to fast-mode operation.  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
11  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
7.3.2.8 POR (Power-On Reset)  
The TMP100 and TMP101 devices both have on-chip, power-on reset circuits that reset the device to default  
settings when the device is powered on. This circuit activates when the power supply is less than 0.3 V for more  
than 100 ms. If the TMP100 and TMP101 devices are powered down by removing supply voltage from the  
device, but the supply voltage is not assured to be less than 0.3 V, TI recommends issuing a General Call reset  
command on the I2C interface bus to ensure that the TMP100 and TMP101 devices are completely reset.  
7.3.3 Timing Diagrams  
The TMP100 and TMP101 devices are Two-Wire, SMBUs, and I2C interface-compatible. Figure 6 to Figure 9  
describe the various operations on the TMP100 and TMP101. The following list provides bus definitions.  
Parameters for Figure 6 are defined in the Timing Requirements section.  
Bus Idle: Both SDA and SCL lines remain HIGH.  
Start Data Transfer: A change in the state of the SDA line, from HIGH to LOW, while the SCL line is HIGH,  
defines a START condition. Each data transfer is initiated with a START condition.  
Stop Data Transfer: A change in the state of the SDA line from LOW to HIGH while the SCL line is HIGH  
defines a STOP condition. Each data transfer is terminated with a repeated START or STOP condition.  
Data Transfer: The number of data bytes transferred between a START and a STOP condition is not limited and  
is determined by the master device. The receiver acknowledges the transfer of data.  
Acknowledge: Each receiving device, when addressed, is obliged to generate an Acknowledge bit. A device  
that acknowledges must pull down the SDA line during the Acknowledge clock pulse in such a way that the SDA  
line is stable LOW during the HIGH period of the Acknowledge clock pulse. Setup and hold times must be taken  
into account. On a master receive, the termination of the data transfer can be signaled by the master generating  
a Not-Acknowledge on the last byte that is transmitted by the slave.  
t(LOW)  
tFC  
t(HDSTA)  
tRC  
SCL  
SDA  
t(SUSTO)  
t(HDSTA)  
t(HIGH) t(SUSTA)  
t(HDDAT)  
t(SUDAT)  
t(BUF)  
tRD  
tFD  
S
P
P
S
Figure 6. I2C Timing Diagram  
12  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
1
9
1
9
SCL  
SDA  
1
0
0
1
A2  
A1 A0 R/W  
0
0
0
0
0
0
P1  
P0  
ACK By  
TMP100 or TMP101  
Start By  
Master  
ACK By  
TMP100 or TMP101  
Frame 1 I2C Slave Address Byte  
Frame 2 Pointer Register Byte  
1
9
1
9
SCL  
(Continued)  
SDA  
(Continued)  
D7 D6  
D5  
D4 D3 D2 D1  
D0  
D7  
D6  
D5  
D4 D3 D2 D1 D0  
ACK By  
TMP100 orTMP101  
ACK By Stop By  
TMP100 or TMP101 Master  
Frame 3 Data Byte 1  
Frame 4 Data Byte 2  
Figure 7. I2C Timing Diagram for Write Word Format  
1
9
1
9
SCL  
SDA  
1
0
0
1
A2  
A1  
A0 R/W  
0
0
0
0
0
0
P1  
P0  
Start By  
Master  
ACK By  
ACK By  
TMP100 or TMP101  
TMP100 or TMP101  
Frame 1 I2C Slave Address Byte  
Frame 2 Pointer Register Byte  
1
9
1
9
SCL  
(Continued)  
SDA  
1
0
0
1
A2  
A1  
A0 R/W  
D7  
D6  
D5  
D4 D3  
D2  
D1  
D0  
(Continued)  
Start By  
Master  
ACK By  
From  
TMP100 or TMP101  
ACK By  
Master  
TMP100 or TMP101  
Frame 3 I2C Slave Address Byte  
Frame 4 Data Byte 1 Read Register  
1
9
SCL  
(Continued)  
SDA  
D7 D6  
D5  
D4  
D3  
D2  
D1  
D0  
(Continued)  
From  
ACK By  
Master  
Stop By  
Master  
TMP100 or TMP101  
Frame 5 Data Byte 2 Read Register  
Figure 8. I2C Timing Diagram for Read Word Format  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
13  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
ALERT  
1
9
1
9
SCL  
SDA  
0
0
0
1
1
0
0
R/W  
1
0
0
1
A2  
A1  
A0  
Sta tus  
Start By  
Master  
ACK By  
From  
NACK By Stop By  
Master  
TMP100 or TMP101  
TMP100 orTMP101 Master  
Frame 1 SMBus ALERT Response Address Byte  
Frame 2 Slave Address From TMP100  
Figure 9. Timing Diagram for SMBus ALERT  
7.4 Device Functional Modes  
7.4.1 Shutdown Mode (SD)  
The Shutdown Mode of the TMP100 and TMP101 devices lets the user save maximum power by shutting down  
all device circuitry other than the serial interface, which reduces current consumption to less than 1 µA. For the  
TMP100 and TMP101 devices, Shutdown Mode is enabled when the SD bit is 1. The device shuts down when  
the current conversion is completed. For SD equal to 0, the device maintains continuous conversion.  
7.4.2 OS/ALERT (OS)  
The TMP100 and TMP101 devices feature a One-Shot Temperature Measurement Mode. When the device is in  
Shutdown Mode, writing 1 to the OS/ALERT bit starts a single temperature conversion. The device returns to the  
shutdown state at the completion of the single conversion. This feature is useful to reduce power consumption in  
the TMP100 and TMP101 devices when continuous monitoring of temperature is not required.  
Reading the OS/ALERT bit provides information about the Comparator Mode status. The state of the POL bit  
inverts the polarity of data returned from the OS/ALERT bit. For POL = 0, the OS/ALERT reads as 1 until the  
temperature equals or exceeds THIGH for the programmed number of consecutive faults, causing the OS/ALERT  
bit to read as 0. The OS/ALERT bit continues to read as 0 until the temperature falls below TLOW for the  
programmed number of consecutive faults when the OS/ALERT bit again reads as 1. The status of the TM bit  
does not affect the status of the OS/ALERT bit.  
7.4.3 Thermostat Mode (TM)  
The Thermostat Mode bit of the TMP101 device indicates to the device whether to operate in Comparator Mode  
(TM = 0) or Interrupt Mode (TM = 1). For more information on comparator and interrupt modes, see the High-  
and Low-Limit Registers section.  
7.4.3.1 Comparator Mode (TM = 0)  
In Comparator Mode (TM = 0), the ALERT pin is activated when the temperature equals or exceeds the value in  
the THIGH register and remains active until the temperature falls below the value in the TLOW register. For more  
information on the Comparator Mode, see the High- and Low-Limit Registers section.  
7.4.3.2 Interrupt Mode (TM = 1)  
In Interrupt Mode (TM = 1), the ALERT pin is activated when the temperature exceeds THIGH or goes below the  
TLOW registers. The ALERT pin is cleared when the host controller reads the temperature register. For more  
information on the interrupt mode, see the High- and Low-Limit Registers section.  
14  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
7.5 Programming  
7.5.1 Pointer Register  
Figure 10 shows the internal register structure of the TMP100 and TMP101 devices. The 8-bit Pointer Register of  
the TMP100 and TMP101 devices is used to address a given data register. The Pointer Register uses the two  
LSBs to identify which of the data registers respond to a read or write command. Table 4 identifies the bits of the  
Pointer Register byte. Table 5 describes the pointer address of the registers available in the TMP100 and  
TMP101 devices. The power-up reset value of P1 and P0 is 00.  
Pointer  
Register  
Temperature  
Register  
SCL  
Configuration  
Register  
I/O  
Control  
Interface  
TLOW  
Register  
SDA  
THIGH  
Register  
Figure 10. Internal Register Structure of the TMP100 and TMP101  
7.5.1.1 Pointer Register Byte (pointer = N/A) [reset = 00h]  
Table 4. Pointer Register Byte  
P7  
P6  
P5  
P4  
P3  
P2  
P1  
P0  
0
0
0
0
0
0
Register Bits  
7.5.1.2 Pointer Addresses of the TMP100 and TMP101 Registers  
Table 5. Pointer Addresses of the TMP100 and TMP101 Registers  
P1  
0
P0  
0
TYPE  
R only, default  
R/W  
REGISTER  
Temperature Register  
Configuration Register  
TLOW Register  
0
1
1
0
R/W  
1
1
R/W  
THIGH Register  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
15  
Product Folder Links: TMP100 TMP101  
 
 
 
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
7.5.2 Temperature Register  
The Temperature Register of the TMP100 or TMP101 devices is a 12-bit, read-only register that stores the  
output of the most recent conversion. Two bytes must be read to obtain data, and are described in Table 6 and  
Table 7. The first 12 bits are used to indicate temperature, with all remaining bits equal to zero. Data format for  
temperature is summarized in Table 1. Following power-up or reset, the Temperature Register reads 0°C until  
the first conversion is complete.  
Table 6. Byte 1 of the Temperature Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
T11  
T10  
T9  
T8  
T7  
T6  
T5  
T4  
Table 7. Byte 2 of the Temperature Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
T3  
T2  
T1  
T0  
0
0
0
0
7.5.3 Configuration Register  
The Configuration Register is an 8-bit read and write register used to store bits that control the operational  
modes of the temperature sensor. Read and write operations are performed MSB-first. The format of the  
Configuration Register for the TMP100 and TMP101 devices is shown in Table 8, followed by a breakdown of the  
register bits. The power-up or reset value of the Configuration Register is all bits equal to 0. The OS/ALERT bit  
reads as 1 after power-up or reset value.  
Table 8. Configuration Register Format  
BYTE  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
1
OS/ALERT  
R1  
R0  
F1  
F0  
POL  
TM  
SD  
7.5.3.1 Shutdown Mode (SD)  
The Shutdown Mode of the TMP100 and TMP101 devices allows the user to save maximum power by shutting  
down all device circuitry other than the serial interface, which reduces current consumption to less than 1 µA. For  
the TMP100 and TMP101 devices, Shutdown Mode is enabled when the SD bit is 1. The device shuts down  
when the current conversion is completed. For SD equal to 0, the device maintains continuous conversion.  
7.5.3.2 Thermostat Mode (TM)  
The Thermostat Mode bit of the TMP101 device indicates to the device whether to operate in Comparator Mode  
(TM = 0) or Interrupt Mode (TM = 1). For more information on comparator and interrupt modes, see High- and  
Low-Limit Registers.  
7.5.3.3 Polarity (POL)  
The Polarity bit of the TMP101 device lets the user adjust the polarity of the ALERT pin output. If the POL bit is  
set to 0 (default), the ALERT pin becomes active low. When the POL bit is set to 1, the ALERT pin becomes  
active high and the state of the ALERT pin is inverted. The operation of the ALERT pin in various modes is  
illustrated in Figure 11.  
16  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
 
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
THIGH  
Measured  
Temperature  
TLOW  
TMP101 ALERT PIN  
(Comparator Mode)  
POL = 0  
TMP101 ALERT PIN  
(Interrupt Mode)  
POL = 0  
TMP101 ALERT PIN  
(Comparator Mode)  
POL = 1  
TMP101 ALERT PIN  
(Interrupt Mode)  
POL = 1  
Read  
Read  
Time  
Read  
Figure 11. Output Transfer Function Diagrams  
7.5.3.4 Fault Queue (F1, F0)  
A fault condition occurs when the measured temperature exceeds the user-defined limits set in the THIGH and  
TLOW Registers. Additionally, the number of fault conditions required to generate an alert can be programmed  
using the Fault Queue. The Fault Queue is provided to prevent a false alert resulting from environmental noise.  
The Fault Queue requires consecutive fault measurements in order to trigger the alert function. If the temperature  
falls below TLOW before reaching the number of programmed consecutive faults limit, the count is reset to 0.  
Table 9 defines the number of measured faults that can be programmed to trigger an alert condition in the  
device.  
Table 9. Fault Settings of the TMP100 and TMP101  
F1  
0
F0  
0
CONSECUTIVE FAULTS  
1
2
4
6
0
1
1
0
1
1
7.5.3.5 Converter Resolution (R1, R0)  
The Converter Resolution bits control the resolution of the internal analog-to-digital converter (ADC), thus  
allowing the user to maximize efficiency by programming for higher resolution or faster conversion time. Table 10  
identifies the Resolution bits and the relationship between resolution and conversion time.  
Table 10. Resolution of the TMP100 and TMP101  
CONVERSION TIME  
R1  
R0  
RESOLUTION  
(Typical)  
0
0
1
1
0
1
0
1
9 bits (0.5°C)  
10 bits (0.25°C)  
11 bits (0.125°C)  
12 bits (0.0625°C)  
40 ms  
80 ms  
160 ms  
320 ms  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
17  
Product Folder Links: TMP100 TMP101  
 
 
 
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
7.5.3.6 OS/ALERT (OS)  
The TMP100 and TMP101 devices feature a One-Shot Temperature Measurement Mode. When the device is in  
Shutdown Mode, writing 1 to the OS/ALERT bit starts a single temperature conversion. The device returns to the  
shutdown state at the completion of the single conversion. This feature is useful to reduce power consumption in  
the TMP100 and TMP101 when continuous temperature monitoring is not required.  
Reading the OS/ALERT bit provides information about the Comparator Mode status. The state of the POL bit  
inverts the polarity of data returned from the OS/ALERT bit. For POL = 0, the OS/ALERT reads as 1 until the  
temperature equals or exceeds THIGH for the programmed number of consecutive faults, causing the OS/ALERT  
bit to read as 0. The OS/ALERT bit continues to read as 0 until the temperature falls below TLOW for the  
programmed number of consecutive faults when the OS/ALERT bit again reads as 1. The status of the TM bit  
does not affect the status of the OS/ALERT bit.  
7.5.4 High- and Low-Limit Registers  
In Comparator Mode (TM = 0), the ALERT pin of the TMP101 becomes active when the temperature equals or  
exceeds the value in THIGH and generates a consecutive number of faults according to fault bits F1 and F0. The  
ALERT pin remains active until the temperature falls below the indicated TLOW value for the same number of  
faults.  
In Interrupt Mode (TM = 1) the ALERT pin becomes active when the temperature equals or exceeds THIGH for a  
consecutive number of fault conditions. The ALERT pin remains active until a read operation of any register  
occurs or the device successfully responds to the SMBus Alert Response Address. The ALERT pin is also  
cleared if the device is placed in Shutdown Mode. When the ALERT pin is cleared, it only becomes active again  
by the temperature falling below TLOW. When the temperature falls below TLOW, the ALERT pin becomes active  
and remains active until cleared by a read operation of any register or a successful response to the SMBus Alert  
Response Address. When the ALERT pin is cleared, the above cycle repeats with the ALERT pin becoming  
active when the temperature equals or exceeds THIGH. The ALERT pin can also be cleared by resetting the  
device with the General Call Reset command. This action also clears the state of the internal registers in the  
device, returning the device to Comparator Mode (TM = 0).  
Both operational modes are represented in Figure 11. Table 11, Table 12, Table 13, and Table 14 describe the  
format for the THIGH and TLOW registers. Power-up reset values for THIGH and TLOW are: THIGH = 80°C and TLOW  
75°C. The format of the data for THIGH and TLOW is the same as for the Temperature Register.  
=
Table 11. Byte 1 of the THIGH Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
H11  
H10  
H9  
H8  
H7  
H6  
H5  
H4  
Table 12. Byte 2 of the THIGH Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
H3  
H2  
H1  
H0  
0
0
0
0
Table 13. Byte 1 of the TLOW Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
L11  
L10  
L9  
L8  
L7  
L6  
L5  
L4  
Table 14. Byte 2 of the TLOW Register  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
L3  
L2  
L1  
L0  
0
0
0
0
All 12 bits for the Temperature, THIGH, and TLOW registers are used in the comparisons for the ALERT function for  
all converter resolutions. The three LSBs in THIGH and TLOW can affect the ALERT output even if the converter is  
configured for 9-bit resolution.  
18  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
 
 
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
8 Application and Implementation  
NOTE  
Information in the following applications sections is not part of the TI component  
specification, and TI does not warrant its accuracy or completeness. TI’s customers are  
responsible for determining suitability of components for their purposes. Customers should  
validate and test their design implementation to confirm system functionality.  
8.1 Application Information  
The TMP100 and TMP101 devices are used to measure the printed circuit board (PCB) temperature of the board  
location where the devices are mounted. The TMP100 features two address pins to allow up to eight devices to  
be addressed on a single I2C interface. The TMP101 device features one address pin and an ALERT pin,  
allowing up to three devices to be connected per bus. The TMP100 and TMP101 devices require no external  
components for operation except for pullup resistors on SCL, SDA, and ALERT (TMP101 device), although a  
0.1-μF bypass capacitor is recommended.  
The sensing device of the TMP100 and TMP101 devices is the chip itself. Thermal paths run through the  
package leads as well as the plastic package. The die flag of the lead frame is connected to GND. The lower  
thermal resistance of metal causes the leads to provide the primary thermal path. The GND pin of the TMP100 or  
TMP101 device is directly connected to the metal lead frame, and is the best choice for thermal input.  
8.2 Typical Application  
Supply Voltage  
2.7 V to 5.5 V  
Supply Voltage  
2.7 V to 5.5 V  
Supply Bypass  
Supply Bypass  
Capacitor  
Capacitor  
Pull-Up Resistors  
Pull-Up Resistors  
0.01 mF  
0.01 mF  
5-k  
5-k  
TMP100  
TMP101  
Two-Wire  
Host Controller  
1
2
3
6
5
4
Two-Wire  
Host Controller  
6
5
4
1
2
3
SDA  
SCL  
SDA  
SCL  
ADD0  
GND  
ADD1  
ADD0  
GND  
ALERT  
V+  
V+  
Figure 12. Typical Connections of the TMP100  
8.2.1 Design Requirements  
Figure 13. Typical Connections of the TMP101  
The TMP100 and TMP101 devices require pullup resistors on the SCL, SDA, and ALERT (TMP101 device) pins.  
The recommended value for the pullup resistor is 5-kΩ. In some applications, the pullup resistor can be lower or  
higher than 5-kΩ but must not exceed 3 mA of current on the SCL and SDA pins, and must not exceed 4 mA on  
the ALERT (TMP101) pin. A 0.1-μF bypass capacitor is recommended, as shown in Figure 12 and Figure 13.  
The SCL, SDA, and ALERT lines can be pulled up to a supply that is equal to or higher than VS through the  
pullup resistors. For the TMP100, to configure one of eight different addresses on the bus, connect ADD0 and  
ADD1 to either the GND pin, V+ pin, or float. Float indicates the pin is left unconnected. For the TMP101 device,  
to configure one of three different addresses on the bus, connect ADD0 to either the GND pin, V+ pin, or float.  
8.2.2 Detailed Design Procedure  
Place the TMP100 and TMP101 devices in close proximity to the heat source that must be monitored, with a  
proper layout for good thermal coupling. This placement ensures that temperature changes are captured within  
the shortest possible time interval. To maintain accuracy in applications that require air or surface temperature  
measurement, care must be taken to isolate the package and leads from ambient air temperature. A thermally-  
conductive adhesive is helpful in achieving accurate surface temperature measurement.  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
19  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
Typical Application (continued)  
8.2.3 Application Curve  
Figure 14 shows the step response of the TMP100 and TMP101 devices to a submersion in an oil bath of 100ºC  
from room temperature (27ºC). The time constant, or the time for the output to reach 63% of the input step, is  
0.9 s. The time-constant result depends on the PCB that the TMP100 and TMP101 devices are mounted. For  
this test, the TMP100 and TMP101 devices are soldered to a two-layer PCB that measures 0.375 inch × 0.437  
inch.  
100  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
35  
30  
25  
-1  
1
3
5
7
9
11 13 15 17 19  
Time (s)  
Figure 14. Temperature Step Response  
20  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
 
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
9 Power Supply Recommendations  
The TMP100 and TMP101 devices operate with power supply in the range of 2.7 V to 5.5 V. A power-supply  
bypass capacitor is required for stability; place this capacitor as close as possible to the supply and ground pins  
of the device. A typical value for this supply bypass capacitor is 0.01 μF. Applications with noisy or high-  
impedance power supplies can require additional decoupling capacitors to reject power-supply noise.  
10 Layout  
10.1 Layout Guidelines  
Place the power-supply bypass capacitor as close as possible to the supply and ground pins. The recommended  
value of this bypass capacitor is 0.01 μF. Additional decoupling capacitance can be added to compensate for  
noisy or high-impedance power supplies. Pull up the open-drain output pins SDA , SCL, and ALERT (TMP101)  
through 5-kΩ pullup resistors.  
10.2 Layout Examples  
Via to Power or Ground Plane  
Via to Internal Layer  
Pull-Up Resistors  
SCL  
SDA  
ADD0  
V+  
GND  
ADD1  
Supply Voltage  
Supply Bypass  
Capacitor  
Ground Plane for  
Thermal Coupling  
to Heat Source  
Serial Bus Traces  
Heat Source  
Figure 15. TMP100 Layout Example  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
21  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
www.ti.com  
Layout Examples (continued)  
Via to Power or Ground Plane  
Via to Internal Layer  
Pull-Up Resistors  
SCL  
GND  
ALERT  
SDA  
ADD0  
V+  
Supply Voltage  
Supply Bypass  
Capacitor  
Ground Plane for  
Thermal Coupling  
to Heat Source  
Serial Bus Traces  
Heat Source  
Figure 16. TMP101 Layout Example  
22  
Submit Documentation Feedback  
Copyright © 2002–2015, Texas Instruments Incorporated  
Product Folder Links: TMP100 TMP101  
TMP100, TMP101  
www.ti.com  
SBOS231I JANUARY 2002REVISED NOVEMBER 2015  
11 Device and Documentation Support  
11.1 Related Links  
The table below lists quick access links. Categories include technical documents, support and community  
resources, tools and software, and quick access to sample or buy.  
Table 15. Related Links  
TECHNICAL  
DOCUMENTS  
TOOLS &  
SOFTWARE  
SUPPORT &  
COMMUNITY  
PARTS  
PRODUCT FOLDER  
SAMPLE & BUY  
TMP100  
TMP101  
Click here  
Click here  
Click here  
Click here  
Click here  
Click here  
Click here  
Click here  
Click here  
Click here  
11.2 Trademarks  
SMBus is a trademark of NXP Semiconductors.  
All other trademarks are the property of their respective owners.  
11.3 Electrostatic Discharge Caution  
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam  
during storage or handling to prevent electrostatic damage to the MOS gates.  
11.4 Glossary  
SLYZ022 TI Glossary.  
This glossary lists and explains terms, acronyms, and definitions.  
12 Mechanical, Packaging, and Orderable Information  
The following pages include mechanical, packaging, and orderable information. This information is the most  
current data available for the designated devices. This data is subject to change without notice and revision of  
this document. For browser-based versions of this data sheet, refer to the left-hand navigation.  
Copyright © 2002–2015, Texas Instruments Incorporated  
Submit Documentation Feedback  
23  
Product Folder Links: TMP100 TMP101  
PACKAGE OPTION ADDENDUM  
www.ti.com  
14-Aug-2015  
PACKAGING INFORMATION  
Orderable Device  
TMP100NA/250  
TMP100NA/250G4  
TMP100NA/3K  
Status Package Type Package Pins Package  
Eco Plan  
Lead/Ball Finish  
MSL Peak Temp  
Op Temp (°C)  
Device Marking  
Samples  
Drawing  
Qty  
(1)  
(2)  
(6)  
(3)  
(4/5)  
ACTIVE  
SOT-23  
SOT-23  
SOT-23  
SOT-23  
SOT-23  
SOT-23  
SOT-23  
SOT-23  
DBV  
6
6
6
6
6
6
6
6
250  
Green (RoHS  
& no Sb/Br)  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
CU NIPDAU  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
Level-2-260C-1 YEAR  
T100  
T100  
T100  
T100  
T101  
T101  
T101  
T101  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
ACTIVE  
DBV  
DBV  
DBV  
DBV  
DBV  
DBV  
DBV  
250  
3000  
3000  
250  
Green (RoHS  
& no Sb/Br)  
Green (RoHS  
& no Sb/Br)  
-55 to 125  
-55 to 125  
-55 to 125  
-55 to 125  
-55 to 125  
-55 to 125  
TMP100NA/3KG4  
TMP101NA/250  
TMP101NA/250G4  
TMP101NA/3K  
Green (RoHS  
& no Sb/Br)  
Green (RoHS  
& no Sb/Br)  
250  
Green (RoHS  
& no Sb/Br)  
3000  
3000  
Green (RoHS  
& no Sb/Br)  
TMP101NA/3KG4  
Green (RoHS  
& no Sb/Br)  
(1) The marketing status values are defined as follows:  
ACTIVE: Product device recommended for new designs.  
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.  
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.  
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.  
OBSOLETE: TI has discontinued the production of the device.  
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability  
information and additional product content details.  
TBD: The Pb-Free/Green conversion plan has not been defined.  
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that  
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.  
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between  
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.  
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight  
in homogeneous material)  
(3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.  
Addendum-Page 1  
PACKAGE OPTION ADDENDUM  
www.ti.com  
14-Aug-2015  
(4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.  
(5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation  
of the previous line and the two combined represent the entire Device Marking for that device.  
(6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish  
value exceeds the maximum column width.  
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information  
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and  
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.  
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.  
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.  
OTHER QUALIFIED VERSIONS OF TMP100, TMP101 :  
Automotive: TMP101-Q1  
Enhanced Product: TMP100-EP  
NOTE: Qualified Version Definitions:  
Automotive - Q100 devices qualified for high-reliability automotive applications targeting zero defects  
Enhanced Product - Supports Defense, Aerospace and Medical Applications  
Addendum-Page 2  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
14-Apr-2015  
TAPE AND REEL INFORMATION  
*All dimensions are nominal  
Device  
Package Package Pins  
Type Drawing  
SPQ  
Reel  
Reel  
A0  
B0  
K0  
P1  
W
Pin1  
Diameter Width (mm) (mm) (mm) (mm) (mm) Quadrant  
(mm) W1 (mm)  
TMP100NA/250  
TMP100NA/3K  
SOT-23  
SOT-23  
DBV  
DBV  
6
6
250  
178.0  
178.0  
9.0  
9.0  
3.23  
3.23  
3.17  
3.17  
1.37  
1.37  
4.0  
4.0  
8.0  
8.0  
Q3  
Q3  
3000  
Pack Materials-Page 1  
PACKAGE MATERIALS INFORMATION  
www.ti.com  
14-Apr-2015  
*All dimensions are nominal  
Device  
Package Type Package Drawing Pins  
SPQ  
Length (mm) Width (mm) Height (mm)  
TMP100NA/250  
TMP100NA/3K  
SOT-23  
SOT-23  
DBV  
DBV  
6
6
250  
180.0  
180.0  
180.0  
180.0  
18.0  
18.0  
3000  
Pack Materials-Page 2  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other  
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest  
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and  
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale  
supplied at the time of order acknowledgment.  
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms  
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary  
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily  
performed.  
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and  
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or  
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information  
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or  
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the  
third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration  
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered  
documentation. Information of third parties may be subject to additional restrictions.  
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service  
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.  
TI is not responsible or liable for any such statements.  
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements  
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support  
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which  
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause  
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use  
of any TI components in safety-critical applications.  
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to  
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and  
requirements. Nonetheless, such components are subject to these terms.  
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties  
have executed a special agreement specifically governing such use.  
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in  
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components  
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and  
regulatory requirements in connection with such use.  
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of  
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.  
Products  
Applications  
Audio  
www.ti.com/audio  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
Automotive and Transportation www.ti.com/automotive  
Communications and Telecom www.ti.com/communications  
Amplifiers  
Data Converters  
DLP® Products  
DSP  
Computers and Peripherals  
Consumer Electronics  
Energy and Lighting  
Industrial  
www.ti.com/computers  
www.ti.com/consumer-apps  
www.ti.com/energy  
dsp.ti.com  
Clocks and Timers  
Interface  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
www.ti.com/industrial  
www.ti.com/medical  
Medical  
Logic  
Security  
www.ti.com/security  
Power Mgmt  
Microcontrollers  
RFID  
power.ti.com  
Space, Avionics and Defense  
Video and Imaging  
www.ti.com/space-avionics-defense  
www.ti.com/video  
microcontroller.ti.com  
www.ti-rfid.com  
www.ti.com/omap  
OMAP Applications Processors  
Wireless Connectivity  
TI E2E Community  
e2e.ti.com  
www.ti.com/wirelessconnectivity  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2015, Texas Instruments Incorporated  

相关型号:

TMP101NA/3K

Digital Temperature Sensor with I2C Interface
TI

TMP101NA/3KG4

TMP10x Temperature Sensor With I2C and SMBus Interface with Alert Function in SOT-23 Package
TI

TMP101NA250

Digital Temperature Sensor with I2C Interface
TI

TMP101NA250G4

Digital Temperature Sensor with I2C Interface
TI

TMP101NA3K

Digital Temperature Sensor with I2C Interface
TI

TMP101NA3KG4

Digital Temperature Sensor with I2C Interface
TI

TMP101NAQDBVRQ1

DIGITAL TEMPERATURE SENSOR WITH I2C INTERFACE
TI

TMP101T1CD13V

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 16V, 50% +Tol, 10% -Tol, 100uF
VISHAY

TMP101T1CD21V

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 16V, 50% +Tol, 10% -Tol, 100uF
VISHAY

TMP101T1CD25V

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 16V, 50% +Tol, 10% -Tol, 100uF
VISHAY

TMP101T1CD26V

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 16V, 50% +Tol, 10% -Tol, 100uF
VISHAY

TMP101T1CD42V

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 16V, 50% +Tol, 10% -Tol, 100uF
VISHAY