Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
960W Single Output Industrial DIN RAIL with PFC Function
SDR-960 series
Features :
AC input 180~264VAC
130% peak load capability
Width only 110mm
Built-in active PFC function compliance to EN61000-3-2
High efficiency 94% and low power dissipation
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Can be installed on DIN rail TS-35/7.5 or 15
UL508(industrial control equipment)approved
EN61000-6-2(EN50082-2) industrial immunity level
Current sharing up to 3840W(3+1)
Built-in DC OK relay contact
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
SDR-960-24
SDR-960-48
DC VOLTAGE
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER
40A
0 ~ 40A
20A
0 ~ 20A
960W
26A
960W
52A
Note.6 1248W (3sec.)
OUTPUT
RIPPLE & NOISE (max.) Note.2 180mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 1.0%
250mVp-p
48 ~ 55V
1.0%
24 ~ 28V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
0.5%
0.5%
1.0%
1.0%
1000ms, 100ms/230VAC at full load
14ms / 230VAC at full load
VOLTAGE RANGE
Note.7 180 ~ 264VAC
47 ~ 63Hz
254 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
PF 0.95/230VAC at full load
94%
EFFICIENCY (Typ.)
94%
INPUT
6A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 50A
<3.5mA / 240VAC
LEAKAGE CURRENT
Normally works within 105 ~ 130% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery
after 30 seconds if the peak load condition is removed
OVERLOAD
Constant current limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power
on to recover
PROTECTION
56 ~ 65V
Protection type : Shut down o/p voltage, with auto-recovery or re-power on to recover
90 (TSW) detect on heatsink of power switch
29 ~ 33V
OVER VOLTAGE
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
60Vdc/0.3A, 24Vdc/1A, 30Vac/0.5A resistive load
Please refer to function manual
DC OK REALY CONTACT RATINGS (max.)
FUNCTION
CURRENT SHARING
-30 ~ +70 (Refer to "Derating Curve")
Note.5
WORKING TEMP.
20 ~ 95% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 4)
Compliance to EN55022 (CISPR22), EN61204-3 , EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A
69.8K hrs min. MIL-HDBK-217F (25
110*125.2*150mm (W*H*D)
)
OTHERS
NOTE
DIMENSION
2.47Kg ; 6pcs/15.8Kg/1.55CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds peak power max. and the average output power should not exceed the rate power.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
960W Single Output Industrial DIN RAIL with PFC Function
SDR-960 series
Mechanical Specification
Case No.214A
Unit:mm
1234
125.2
CN205
1234
1
2
3
4
5
6
TB1
1
2
3
TB2
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Terminal Pin No. Assignment (TB1)
Pin No. Assignment
Terminal Pin No. Assignment (TB2)
Pin No. Assignment
Control Pin (CN205) : DINKLE ECH250R-04P or equivalent
Pin No.
Assignment
Mating Housing
Wire Diameter
DINKLE ESC250V-04P
1
2
3
FG
1,2,3 DC OUTPUT +V
1
2
P-(Current Share)
P+(Current Share)
DC OK Relay Contact
0.081~0.517mm2
(28~20AWG)
or equivalent
(Including in the
single package)
AC/N
AC/L
3,4,6
DC OUTPUT -V
3,4
Block Diagram
PFC fosc : 65KHz
PWM fosc : 60KHz
DC OK
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
+V
-V
I/P
CIRCUIT
O.C.P.
U.V.P.
O.L.P.
DETECTION
CIRCUIT
FG
PWM & PFC
CONTROL
PFC
CURRENT
SHARE
CONTROL
CURRENT SHARE
O.V.P.
DC OK Relay Contact
Contact Close
Contact Open
PSU turns on / DC OK.
PSU turns off / DC Fail.
Contact Ratings (max.) 30V/1A resistive load.
File Name:SDR-960-SPEC 2012-09-07
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com
960W Single Output Industrial DIN RAIL with PFC Function
SDR-960 series
Peak Loading
( 1 )
( 2 )
1248W
1248W
960W
480W
50 sec.
3 sec.
15 sec. 3 sec.
Derating Curve
Output derating VS input voltage
100
90
80
70
60
50
40
130
100
80
For 3 sec. (typ.)
Continuous
60
40
20
-30
0
10
20
30
40
50
60
70 (VERTICAL)
180
190
200
210
220
230
240
250
264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz
Function Manual
1. Current sharing
(1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel).
(2) Difference of output voltages among parallel units should be less than 0.2V.
(3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9.
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
(5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
(6) When in parallel operation, the minimum output load should be greater than 5% of total output load.
(Min. load >5% rated current per unit x number of unit)
(7) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition.
The other PSUs (slaves) may go into standby mode and their output LEDs & relays will not turn on.
(8) Some minor noise may be heard at light load condition under parallel operation.
This is a normal phenomenon and the performance of the PSU will not be influenced.
PSU
PSU
PSU
PSU
TB2
+V
TB2
+V
TB2
+V
TB2
-V +V
-V
-V
-V
CN205
CN205
CN205
CN205
1
2
3
4
P-
P+
DC OK
DC OK
1
2
3
4
P-
P+
DC OK
DC OK
1
2
3
4
P-
P+
DC OK
DC OK
1
2
3
4
P-
P+
DC OK
DC OK
P-(pin1)
P+(pin2)
P+ and P- lines
should be twisted in pairs
-V
+V
LOAD
File Name:SDR-960-SPEC 2012-09-07
相关型号:
©2020 ICPDF网 联系我们和版权申明