TEN402423WIR [TRACOPOWER]
DC/DC Converters;![TEN402423WIR](http://pdffile.icpdf.com/pdf2/p00323/img/icpdf/TEN402410WIR_1986266_icpdf.jpg)
型号: | TEN402423WIR |
厂家: | ![]() |
描述: | DC/DC Converters |
文件: | 总4页 (文件大小:352K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converters
TEN 40WIR Series, 40 Watt
CB
Scheme
UL 60950-1
UL 60950-1
Features
◆ 2” x 1” metal package
◆ Ultra wide 4:1 input voltage range
9–36, 18–75, 43–160 VDC
◆ EN 50155 approval for railway
applications
◆ Thermal shock and vibration resistant
according EN 61373
◆ High efficiency up to 92%
◆ No minimum load required
◆ Operating temperature range
–40°C to +85°C
The TEN 40WIR series is a family of high performance 40 Watt dc/dc converter
modules featuring ultra wide 4:1 input voltage ranges in a 2” x 1” package with
industry-standard footprint. Input voltages up to 160 VDC, excellent EMC char-
acteristics and EN 50155 approval make this product the best choice for many
demanding applications in railroad and transportation systems. Further standard
features include remote On/Off, over voltage protection, under voltage lockout and
short circuit protection. Low input current characteristics at minimal load make these
converters also the ideal solution for battery-operated systems. Typical applications
are in wireless networks, telecom/datacom, industry control systems and measure-
ment equipments.
◆ Under voltage lock-out circuit
◆ Remote On/Off
◆ Output voltage adjustable
◆ Lead free design, RoHS compliant
◆ 3-year product warranty
Models
Order code
Input voltage range
Output voltage
Output current max.
Efficiency typ.
TEN 40-2410WIR
TEN 40-2411WIR
TEN 40-2412WIR
TEN 40-2413WIR
TEN 40-2415WIR
TEN 40-2422WIR
TEN 40-2423WIR
TEN 40-4810WIR
TEN 40-4811WIR
TEN 40-4812WIR
TEN 40-4813WIR
TEN 40-4815WIR
TEN 40-4822WIR
TEN 40-4823WIR
TEN 40-7210WIR
TEN 40-7211WIR
TEN 40-7212WIR
TEN 40-7213WIR
TEN 40-7215WIR
TEN 40-7222WIR
TEN 40-7223WIR
3.3 VDC
5.0 VDC
12 VDC
15 VDC
24 VDC
12 VDC
15 VDC
3.3 VDC
5.0 VDC
12 VDC
15 VDC
24 VDC
12 VDC
15 VDC
3.3 VDC
5.0 VDC
12 VDC
15 VDC
24 VDC
12 VDC
15 VDC
10‘000 mA
8000 mA
3333 mA
2666 mA
1666 mA
1666 mA
1333 mA
10‘000 mA
8000 mA
3333 mA
2666 mA
1666 mA
1666 mA
1333 mA
10‘000 mA
8000 mA
3333 mA
2666 mA
1666 mA
1666 mA
1333 mA
90 %
91 %
91 %
91 %
91 %
90 %
90 %
90 %
91 %
92 %
92 %
91 %
90 %
90 %
88 %
89 %
90 %
90 %
90 %
89 %
89 %
9 – 36 VDC
(24 VDC nominal)
18 – 75 VDC
(48 VDC nominal)
43 – 160 VDC
(110 VDC nominal)
http://www.tracopower.com
Page 1 of 4
DC/DC Converters
TEN 40WIR Series 40 Watt
Input Specifications
Input current (no load)
24 Vin models: 15 mA typ.
48 Vin models: 10 mA typ.
110 Vin models: 6 mA typ.
Start-up voltage
24 Vin models: < 9.0 VDC
48 Vin models: < 18 VDC
110 Vin models: < 43 VDC
Under voltage shut down (lock-out circuit)
Surge voltage (1 sec.)
24 Vin models: 8.0 VDC typ.
48 Vin models: 16 VDC typ.
110 Vin models: 40 VDC typ.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
110 Vin models: 170 V max.
Reflected ripple current
Conducted noise
20 mAp-p typ.
EN 55022 class Awith external components
see: application note
ESD (electrostatic discharge)
EN 61000-4-2, air 8 kV, contact 6 kV,
perf. criteria A
Radiated immunity
EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / surge (with external input capacitor)
EN 61000-4-4, 2 kV, perf. criteria A
EN 61000-4-5, 2 kV perf. criteria A
– external input capacitor
24 & 48 Vin models: Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
110 Vin models: Ruby-con BXF 68 µF, 200 V, 3pcs in parallel.
Conducted immunity
EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy
1 %
Voltage adjustment range (single output models only)
15 & 24 VDC models: +20%, -10%
other models: 10 %
Regulation
– Input variation Vin min. to Vin max.
– Load variation 0 – 100 %
0.2 % max.
single output models: 0.5 % max.
dual output models: 1 % max.
– Load cross variation 25 % / 100 %
5 % max.
not required
0.02 %/K
Minimum load
Temperature coefficient
Ripple and noise (20 MHz bandwidth,
measured with 1 µF/ 50 V MLCC)
3.3 & 5.0 VDC models: 75 mVp-p max.
24 VDC models: 150 mVp-p max.
other models: 100 mVp-p max.
Start up time
(constant resistive load)
– Power On
– Remote On
60 ms typ.
60 ms typ.
Transient response (25% load step change)
Short circuit protection
250 µs typ.
indefinite (automatic recovery)
150 % of Iout max. typ.
3.3 VDC models: 3.9 V
Over load protection
Over voltage protection (only single output models)
5 VDC models: 6.2 V
12 VDC models: 15 V
15 VDC models: 20 V
24 VDC models: 31 V
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 4
DC/DC Converters
TEN 40WIR Series 40 Watt
Output Specifications
Capacitive load (max. values)
3.3 VDC models: 26’600 µF
5.0 VDC models: 20’000 µF
12 VDC models: 3900 µF
15 VDC models: 2600 µF
24 VDC models: 1300 µF
12 VDC models: 2600 µF (each output)
15 VDC models: 1600 µF (each output)
General Specifications
Temperature ranges
– Operating
–40°C to +85°C (with derating)
– Casing temperature
– Storage
+105°C max.
–55°C to +125°C
Power derating
– Natural convection
– Natural convection with heat sink (optional)
2.5 %/K above 60°C
2.8 %/K above 65°C
Thermal impedance
– Natural convection
– Natural convection with heat sink (optional)
10.8 K/W
10.3 K/W
Humidity (non condensing)
5 – 95 % rel. H
Isolation voltage (60 sec.) – Input / Output
1600 VDC
Isolation resistance
Isolation capacitance
Switching frequency
– Input / Output
– Input / Output
>10’000 M Ohm
1’500 pF max.
250 kHz typ. (pulse width modulation PWM)
Thermal shock, mechanical shock & vibration
EN 61373, MIL-STD-810F
– Test conditions
www.tracopower.com/products/mil810.pdf
Safety standards
UL/cUL 60950-1, IEC/EN 60950-1, EN 50155
www.ul.com -> certifications -> File e188913
Safety approvals
Remote On/Off
– UL/cUL (entry pending)
– On:
– Off:
– Off idle current:
3.0 ... 12 VDC or open circuit
0 ... 1.2 VDC or short circuit pin 2 and pin 6
3.0 mA
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)
370’000 h
Environmental compliance – Reach
www.tracopower.com/products/ten40wir-reach.pdf
RoHS directive 2002/95/EC
– RoHS
Output Voltage Adjustment (for single output models only)
Trim up
Trim down
Trim
+Vout
Rd
Ru
Trim
-
Vout
Nominal output voltage at open Trim input
Ru, Rd for adjustment to be adviced
Application note: www.tracopower.com/products/ten40wir-application.pdf
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 3 of 4
DC/DC Converters
TEN 40WIR Series 40 Watt
Physical Specifications
Casing material
copper
Baseplate material
Potting material
non conductive FR4
silicon (UL94V-0 rated)
21.5 g (0.76 oz)
Weight
Soldering temperature
max. +265°C / 10 sec.
Outline Dimensions
50.8
(2.0)
Pin-Out
Pin
1
Single
Dual
4
1
2
+Vin (Vcc)
+Vin (Vcc)
Bottom View
5
6
2
–Vin (GND) –Vin (GND)
Remote On/Off
3
3
4
+Vout
–Vout
TRIM
+Vout
Common
–Vout
(1.8)
2.54 (0.1)
45.72
5
6
Dimensions in [mm], () = Inch
Pin diameter: 1.0 0.1 (0.04 0.004)
Pin pitch tolerances: 0.25 ( 0.01)
Case tolerances: 0.5 ( 0.02)
Heat-Sink (Option)
Order code: TEN-HS1
(cont.: heat-sink, thermal pad, 2 clamps)
Aluminum
Anodic treatment (black)
17g (0.60oz) without converter
Material:
Finish:
Weight:
56.0 (2.2) max.
Thermal impedance after assembling: 10.3 K/W
Heat-sink
Thermal pad
Clamp
Converter
Note:
Before attaching the heatsink, the product
label on converter has to be removed for
optimal performance.
16.8 (0.66)
max.
For volume orders we can supply the
converters with heatsink already mounted.
Please contact us for a relative quotation.
Dimensions in mm, () = Inch
Rev. 01/12
Specifications can be changed any time without notice.
Jenatschstrasse 1 · CH-8002 Zurich · Switzerland
Tel. +41 43 311 45 11 · Fax +41 43 311 45 45 · info@traco.ch · www.tracopower.com
Page 4 of 4
相关型号:
©2020 ICPDF网 联系我们和版权申明