TFS280F [VECTRON]

Filter specification; 过滤器规格
TFS280F
型号: TFS280F
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:68K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Filename: tfs280f.doc  
version 1.0  
26.06.2002  
VI TELEFILTER  
Filter specification  
TFS 280 F  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
terminating impedances *  
Input:  
22  
0
C
dBm  
2
540  
230  
-4,9 pF  
-6,3 pF  
Output:  
Characteristics  
Remark:  
The reference level for the relative attenuation a  
of TFS280F is the minimum of the pass band attenuation a  
. This value is defined as the  
min  
rel  
insertion loss a . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level  
relative to the insertion loss a . The given values for the relative attenuation a and the group delay ripple have to be reached at the frequencies  
given below, even if the centre frequency f is shifted due to the temperature coefficient of frequency TC in the operating temperature range and  
due to a production tolerance for the centre frequency f .  
e
c
e
rel  
c
f
c
D a t a  
typ. value  
7,5 dB  
limit  
Insertion loss  
a
= a  
min  
max. 10  
dB  
e
Nominal frequency  
Centre frequency  
3 dB- BW  
f
f
280  
280,0 MHz  
-
N
c
MHz  
MHz  
280,0  
25,5  
MHz  
min  
17  
MHz  
Relative attenuation  
a
rel  
8,5 MHz  
fN  
-
8,5 MHz ... fN  
+
0,3  
dB  
max.  
1
dB  
10  
30  
60  
MHz ... fN  
MHz ... fN  
MHz ... fN  
-
+
+
30  
60  
220  
MHz  
MHz  
MHz  
45 -50 dB  
42 -50 dB  
min. 40  
min. 38  
min. 40  
dB  
dB  
dB  
fN  
fN  
+
+
65  
dB  
Group delay ripple GD  
N 8,5 MHz ... fN + 8,5 MHz  
f
35  
ns  
max. 100  
max. + 10  
ns  
Input power level  
dBm  
Operating temperature range  
Storage temperature range  
22  
C
- 30 C ... + 75 C  
- 40 C ... + 85 C  
Temperature coefficient of frequency  
TCf  
-87  
ppm/K  
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as  
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.  
Generated:  
Checked / approved:  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs280f.doc  
version 1.0  
26.06.2002  
VI TELEFILTER  
Filter specification  
TFS 280 F  
2/5  
Construction and pin connection  
(All dimensions in mm)  
+0.15  
-0.1  
5.0 SQ  
7
5
S280F  
P18  
1
3
Date code  
1
2
3
4
5
6
7
8
Ground  
Input RF return  
Input  
Ground  
Ground  
Output  
Output RF return  
Ground  
Datecode  
Year + week  
2000  
2001  
M
N
P
2002  
...  
50 test circuit  
L1  
L2  
3
6
Output  
50 Ohm  
Input  
SAW  
50 Ohm  
C2  
C1  
1,2,4,5,7,8  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs280f.doc  
version 1.0  
26.06.2002  
VI TELEFILTER  
Filter specification  
TFS 280 F  
3/5  
Stability characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Change of  
temperature:  
-55 °C to 125°C / 30 min. each / 10 cycles  
DIN IEC 68 part 2 14 Test N  
4. Resistance to  
solder heat (reflow):  
reflow possible: twice max.;  
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page  
4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
Reel of empty components at start:  
Reel of empty components at start including leader:  
Trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
:
12  
4
± 0,3  
± 0,1  
Po  
P
2
Po  
:
D
o
Do  
:
1,5 + 0,1  
E
F
Ao  
E
:
:
1,75 ± 0,1  
5,5 ± 0,05  
0,75  
D 1  
F
W
Bo  
CT  
G (min) :  
P2  
P1  
:
2
8
± 0,05  
± 0,10  
G
:
P1  
D1(min) : 1,5  
COVER TAPE  
Ao  
Bo  
:
:
5,30 ± 0,1  
5,30 ± 0,1  
CT  
:
9,5 ± 0,1  
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
12,4 ± 2,0  
W2 (max) :  
18,4  
N (min)  
C
:
50  
C
A
:
13 ± 0.2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs280f.doc  
version 1.0  
26.06.2002  
VI TELEFILTER  
Filter specification  
TFS 280 F  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
Filename: tfs280f.doc  
version 1.0  
26.06.2002  
VI TELEFILTER  
Filter specification  
TFS 280 F  
5/5  
History  
Version  
Reason of Changes  
new generation  
Name  
Date  
1.0  
Chilla  
26.06.2002  
VI TELEFILTER  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS280G

Filter specification
VECTRON

TFS280G_06

Filter specification
VECTRON

TFS280H

Filter specification
VECTRON

TFS280H_06

Filter specification
VECTRON

TFS280K_04

Filter specification
VECTRON

TFS280L_04

Filter specification
VECTRON

TFS280R

Vectron International Filter specification
VECTRON

TFS281

Vectron International Filter specification
VECTRON

TFS281A

Vectron International Filter specification
VECTRON

TFS282A

Filter Specification
VECTRON

TFS282A1

Filter Specification
VECTRON

TFS282A_01

Filter Specification
VECTRON