NL1012T_17 [VIMARLOW]

Single-Stage Thermoelectric Module;
NL1012T_17
型号: NL1012T_17
厂家: II-VI Marlow, Inc.    II-VI Marlow, Inc.
描述:

Single-Stage Thermoelectric Module

文件: 总3页 (文件大小:542K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical Data Sheet for NL1012T  
Single-Stage Thermoelectric Module  
NOMINAL PERFORMANCE IN NITROGEN  
Hot Side Temperature (°C)  
Δ Tmax (°C):  
Qmax (watts):  
Imax (amps):  
Vmax (vdc):  
27  
61  
2.1  
1.0  
3.7  
3.24  
0.77  
50  
68  
2.4  
1.0  
4.2  
--  
AC Resistance (ohms):  
Device ZT  
--  
PRODUCT FEATURES  
ORDERING OPTIONS  
Model Number  
Description  
TEM, Top and Base Metallized  
Exterior  
TEM, Base Metallized Exterior  
TEM, No Metallized Exterior  
TEM, Top and Base Pre-Tinned with  
117°C Solder.  
RoHS EU Compliant  
Ceramic Material: Aluminum Oxide  
Maximum process temperature is 120°C.  
01AC, -02AC, -04AC: Metallized Exterior Surfaces are Au  
flash, suitable for soldering.  
-04AC: Height dimension includes metallization and  
excludes solder.  
NL1012T-01AC  
NL1012T-02AC  
NL1012T-03AC  
NL1012T-04AC  
OPERATION CAUTIONS  
INSTALLATION  
For maximum reliability, storage and operation below  
100°C in a non-condensing environment is recommended.  
To minimize thermal stress when operating in cooling  
mode, use linear/proportional temperature control or a  
similar method rather than an ON/OFF method.  
Recommended mounting methods: Bonding with thermal  
epoxy or soldering with metallized ceramics. For additional  
information, please refer to our TEC Installation Guide.  
II-VI Marlow Dallas, TX USA  
214-340-4900  
877-627-5691  
marlow.sales@ii-vi.com  
Marlow Industries Europe  
GmbH - Germany  
+49 (0) 6150 5439 - 403  
info@marlow-europe.eu  
II-VI Japan Inc.  
81 43 297 2693 (tel)  
center@ii-vi.co.jp  
www.ii-vi.co.jp  
II-VI Singapore Pte., Ltd.  
(65) 6481 8215 (tel)  
info@ii-vi.com.sg  
Marlow Industries China, II-VI  
Technologies Beijing  
86-10-643 98226  
info@iivibj.com  
MI Form 005-0808 Rev. A  
DOC # 102-0291 REV J - PAGE 1 OF 3  
www.marlow.com  
ENVIRONMENT: ONE ATMOSPHERE DRY NITROGEN  
Hot Side Temperature 27°C  
Hot Side Temperature 50°C  
HEAT  
LOAD  
HEAT  
(WATTS)  
80.0  
60.0  
40.0  
20.0  
0.0  
80.0  
60.0  
40.0  
20.0  
LOAD  
(WATTS)  
0.00  
0.25  
0.50  
0.75  
1.00  
1.25  
1.50  
1.75  
2.00  
2.25  
0.00  
0.25  
0.50  
0.75  
1.00  
1.25  
1.50  
1.75  
2.00  
0.0  
4.0  
3.0  
2.0  
1.0  
0.0  
3.0  
2.0  
1.0  
Q=0  
T=0  
Q=0  
T=0  
0.0  
0.0  
0.2  
0.4  
0.6  
0.8  
1.0  
0.0  
0.2  
0.4  
0.6  
0.8  
1.0  
CURRENT (AMPS)  
CURRENT (AMPS)  
POWER GENERATION PERFORMANCE CURVES  
Hot Side Temperature (°C)  
Hot Side Temperature (°C)  
55  
60  
65  
70  
75  
80  
85  
30 35 40 45 50 55  
65  
75  
85  
0.014  
0.012  
0.01  
0.3  
0.25  
0.2  
0.15  
0.1  
0.05  
0
0.04  
0.035  
0.03  
0.025  
0.02  
0.015  
0.01  
0.005  
0
0.5  
0.45  
0.4  
Tc=50°C  
Tc=27°C  
0.35  
0.3  
0.008  
0.006  
0.004  
0.002  
0
0.25  
0.2  
0.15  
0.1  
0.05  
0
Power  
0.7  
Voltage  
Power  
1.1  
Voltage  
0.1  
0.3  
0.5  
Heat (W)  
0.1  
0.3  
0.5  
0.7  
0.9  
1.3  
1.5  
Heat (W)  
Normalized Off-Peak Performance  
1
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
1
0.9  
Hot Side Temperature (°C)  
Cold Side Temperature (°C)  
Optimum Efficiency, η (%)  
Optimum Power (W)  
85  
27  
55  
27  
35  
27  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
2.52 1.28 0.37  
0.038 0.009 0.001  
0.446 0.213 0.060  
5.23 4.88 4.65  
0.78 0.37 0.11  
0.20 0.10 0.03  
38.51 38.56 38.50  
Optimum Voltage (V)  
Load Resistance for Opt η (Ω)  
Open Circuit Voltage, VOC (V)  
Short Circuit Current (A)  
Thermal Resistance (°C/W)  
Efficiency  
Voltage  
0
1
2
3
4
5
6
7
8
9
10  
Load Resistance Ratio  
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, contact one of our Applications Engineers at 877-627-5691.  
MI Form 005-0808 Rev. A  
DOC # 102-0291 REV J - PAGE 2 OF 3  
www.marlow.com  
Dimensions are in inches, and millimeters are in [ ].  
* NOTE: Cold Side, Hot Side, and Positive and Negative Leads are valid only for thermoelectric cooling.  
For power generation, refer to figure below.  
For customer support or general questions please contact a local office or visit our website at www.marlow.com.  
Power Generation performance information is given in a nitrogen environment and cold side temperatures of 27°C and 50°C.  
Module temperature does not include thermal resistance of heat sinks. For performance information in vacuum, other cold side  
temperatures, or specific heat sinks, consult one of our applications engineers.  
TYPICAL POWER GENERATION CONFIGURATION  
EXAMPLE:  
MI Form 005-0808 Rev. A  
DOC # 102-0291 REV J - PAGE 3 OF 3  
www.marlow.com  

相关型号:

NL1013T

Single-Stage Thermoelectric Module
VIMARLOW

NL1013T-01AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1013T-02AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1013T-03AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1013T-04AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1013T_17

Single-Stage Thermoelectric Module
VIMARLOW

NL1015T

Single-Stage Thermoelectric Module
VIMARLOW

NL1015T-01

Thermoelectric Cooler
ETC

NL1015T-01AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1015T-02

Thermoelectric Cooler
ETC

NL1015T-02AC

Single-Stage Thermoelectric Module
VIMARLOW

NL1015T-03

Thermoelectric Cooler
ETC