VHR30-2805D [VPT]
HIGH RELIABILITY COTS DC-DC CONVERTERS;型号: | VHR30-2805D |
厂家: | VPT, Inc. |
描述: | HIGH RELIABILITY COTS DC-DC CONVERTERS DC-DC转换器 |
文件: | 总10页 (文件大小:2058K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
,
VHR30-2800D SERIES
HIGH RELIABILITY COTS DC-DC CONVERTERS
Models Available
Input: 15 V to 50 V continuous, 80 V transient
30 W, dual outputs of 5 V, 12 V, 15 V
-40 °C to 100 °C Operation
1.0 DESCRIPTION
1.1 FEATURES
The VHR series of industrial grade DC-DC converters provides cost
effective, high reliability solutions for use in defense, avionics and
manufacturing industries. The VHR industrial grade products
leverage decades of VPT's proven heritage in military and
aerospace electronics.
• High Reliability at Low Cost
• 30 Watts Output Power
• Wide Input Voltage Range: 15 to 50 Volts per MIL-STD-704 and
MIL-STD-1275
• High Input Transient Voltage: 80 Volts for 1 sec per
MIL-STD-704A
VPT’s VHR30-2800D series is ideal for non flight-critical solutions in
military, avionics, unmanned systems as well as manufacturing
equipment and controls. A wide input voltage range which
accommodates nominal 28 V inputs, low input and output ripple,
fixed operating frequency and companion EMI filters simplify
system design while ensuring operating success in the most rugged
of environments.
• Input Undervoltage Lockout
• Fixed Frequency
• Frequency Synchronization
• Output Soft Start
• Current Limit Protection
• Short Circuit Protection
• Magnetic Feedback, no Optoisolators
• Wide Temperature Range, -40 °C to 100 °C
• Internally Conformal Coated
• Standard Six Sided Non-Hermetic Rugged Metal Package
These converters are designed and manufactured in a facility
certified to ISO9001, J-STD-001 and IPC-A-610.
This product may incorporate one or more of the following U.S.
patents:
1.2 COMPLIANCE
• MIL-STD-1275
• MIL-STD-704
5,784,266
5,790,389
5,963,438
5,999,433
6,005,780
6,084,792
6,118,673
• Meets MIL-STD-461C-F and EN55022 when used with an
appropriate VHR EMI Filter
1.3 PACKAGING
• Low-profile: 1.885” x 1.325” x 0.400”
• Max weight: 48 g
1.4 SIMILAR PRODUCTS AND ACCESSORIES
• DVTR 40 W dual output DC-DC Converter
• VPT30 30 W dual output COTS DC-DC Converter
• EMI filters, Thermal Pads, Front-End Modules and Accessories
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
1
VHR30-2800D SERIES DATASHEET
2.0 DESCRIPTION
2.1 BLOCK DIAGRAM
2.2 CONNECTION DIAGRAM
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
2
VHR30-2800D SERIES DATASHEET
2.2 CONNECTION DIAGRAM (CONTINUED)
Inhibit Circuit (Shown with optional capacitor for turn-on delay)
Stacked Output Connection (Shown with optional EMI filter)
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
3
VHR30-2800D SERIES DATASHEET
3.0 SPECIFICATIONS
3.1 ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings
Input Voltage (Continuous):
Input Voltage (Transient, 1 second):
50 V
80 V
Operating Temperature (Full Load):
Storage Temperature:
Lead Solder Temperature (10 seconds):
-40 °C to 100 °C
-55 °C to 125 °C
300 °C
3.2 PERFORMANCE SPECIFICATIONS
4
Tcase = -40 °C to 100 °C, Vin = +28 V ± 5%, Full Load , Unless Otherwise Specified
VHR30-2805D
VHR30-2812D
Parameter
INPUT
Conditions
Min
Typ
Max
Min
Typ
Max
Units
Voltage
Continuous
15
-
28
-
50
80
15
-
28
-
50
80
V
V
3
Transient, 1 sec
INH < 1.5 V
No Load
20 Hz to 10 MHz
Turn On
Current
-
-
-
4
50
30
-
6
90
75
-
-
-
4
50
30
-
6
90
75
mA
mA
mApp
V
Ripple Current
Undervoltage Lockout
12
14.8
12
14.8
3
11
-
14.5
11
-
14.5
V
Turn Off
OUTPUT STATIC
Voltage
+Vout, TCASE = 25 °C
4.92
5
5.08
11.82
12
12.18
V
+Vout, TCASE = -40 °C to 100 °C
-Vout, TCASE = 25 °C
-Vout, TCASE = -40 °C to 100 °C
4.87
4.87
4.82
5
5
5
5.13
5.13
5.18
11.7
11.7
11.58
12
12
12
12.3
12.3
12.42
V
V
V
2,5
Total
0
0
0
-
-
-
30
21
0
0
0
-
-
-
30
21
W
W
A
Power
Either Output
Either Output
2,5
4.2
1.75
Current
Ripple Voltage
Line Regulation
20 Hz to 10 MHz
+Vout, VIN = 15 V to 50 V
-Vout, VIN = 15 V to 50 V
-
-
-
15
1
80
50
10
150
-
-
-
25
1
80
50
10
150
mVpp
mV
mV
6
+Vout, No Load to Full Load
-
-
1
10
-
-
1
10
mV
mV
Load Regulation
-Vout, No Load to Full Load
30
100
30
150
Cross Regulation, -Vout
+Vout: 70% load, -Vout: 30% load
+Vout: 30% load, -Vout: 70% load
-
200
400
-
300
500
mV
3
Load Fault Power Dissipation
-
-
-
-
16
16
-
-
-
-
14
14
W
W
Overload
Short Circuit
OUTPUT DYNAMIC
Load Step, Half to Full Load
Output Transient
-
-
-
100
40
300
200
600
-
-
-
250
200
700
450
400
mVpk
µs
1
Recovery
3
Output Transient
300
1100
mVpk
Line Step , Vin = 16 V to 40 V
1
-
150
400
-
300
500
µs
Recovery
Turn On, Vin = 0 to 28 V
Delay
Overshoot
-
-
10
0
20
25
-
-
10
0
20
50
ms
mVpk
FUNCTION
3
Output Inhibited
0
-
1.5
0
-
1.5
V
INH Pin Input
3
Output Enabled
9
11
-
13
9
11
-
13
V
INH Pin Open Circuit Voltage
SYNC Frequency Range
VH – VL = 5 V, D = 50%
500
600
500
600
kHz
GENERAL
Efficiency
74
-
81
-
-
79
-
84
-
-
%
3
Either Output
500
500
µF
Capacitive Load
Switching Frequency
Isolation
Weight
400
100
-
-
450
-
-
550
400
100
-
-
450
-
-
550
kHz
MΩ
g
500 V DC, Tcase = 25 °C
GM @ Tcase = 55 °C
-
48
-
-
48
-
MTBF (MIL-HDBK-217F)
371
371
kHr
1.
2.
3.
4.
5.
6.
Time for output voltage to settle within 1% of its nominal value
Derate linearly to 0 at 110 °C
Verified by qualification testing
Half Load at +VOUT and half load at -VOUT
Up to 70% of the total power or current can be drawn from any one of the two outputs
5% Load to Full Load at -40 °C
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
4
VHR30-2800D SERIES DATASHEET
3.2 PERFORMANCE SPECIFICATIONS (CONTINUED)
4
Tcase = -40 °C to 100 °C, Vin = +28 V ± 5%, Full Load , Unless Otherwise Specified
VHR30-2815D
Parameter
INPUT
Conditions
Min
Typ
Max
Units
Voltage
Continuous
15
-
28
-
50
80
V
V
3
Transient, 1 sec
INH < 1.5 V
No Load
20 Hz to 10 MHz
Turn On
Current
-
-
-
4
50
30
-
6
90
75
mA
mA
mApp
V
Ripple Current
Undervoltage Lockout
12
14.8
3
11
-
14.5
V
Turn Off
OUTPUT STATIC
Voltage
+Vout, Tcase = 25 °C
+Vout, Tcase = -40 °C to 100 °C
- Vout, Tcase = 25 °C
14.77
14.62
14.62
14.47
15
15
15
15
15.23
15.38
15.38
15.53
V
V
V
V
- Vout, Tcase = -40 °C to 100 °C
2,5
Total
0
0
0
-
-
-
30
21
W
W
A
Power
Either Output
Either Output
2,5
1.4
Current
Ripple Voltage
Line Regulation
20 Hz to 10 MHz
+Vout, Vin = 15 V to 50 V
- Vout, Vin = 15 V to 50 V
-
-
-
25
1
80
50
10
150
mVpp
mV
mV
6
+Vout, No Load to Full Load
-
-
1
10
mV
mV
Load Regulation
- Vout, No Load to Full Load
30
150
Cross Regulation, -Vout
+Vout: 70% load, -Vout: 30% load
+Vout: 30% load, -Vout: 70% load
-
300
500
mV
3
Load Fault Power Dissipation
-
-
-
-
14
14
W
W
Overload
Short Circuit
OUTPUT DYNAMIC
Load Step, Half to Full Load
Output Transient
-
-
-
250
200
700
450
400
mVpk
µs
1
Recovery
3
Output Transient
1100
mVpk
Line Step , Vin = 16 V to 40 V
1
-
300
500
µs
Recovery
Turn On, Vin = 0 to 28 V
Delay
Overshoot
-
-
10
0
20
50
ms
mVpk
FUNCTION
3
Output Inhibited
0
-
1.5
V
INH Pin Input
3
Output Enabled
9
11
-
13
V
INH Pin Open Circuit Voltage
SYNC Frequency Range
GENERAL
VH – VL = 5 V, D = 50%
500
600
kHz
Efficiency
79
-
84
-
-
%
3
Either Output
500
µF
Capacitive Load
Switching Frequency
Isolation
Weight
400
100
-
-
450
-
-
550
kHz
MΩ
g
500 V DC, Tcase = 25 °C
GM @ Tcase = 55 °C
-
48
-
MTBF (MIL-HDBK-217F)
371
kHr
1.
2.
3.
4.
5.
6.
Time for output voltage to settle within 1% of its nominal value
Derate linearly to 0 at 110 °C
Verified by qualification testing
Half Load at +VOUT and half load at -VOUT
Up to 70% of the total power or current can be drawn from any one of the two outputs
5% Load to Full Load at -40 °C
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
5
VHR30-2800D SERIES DATASHEET
4.0 PERFORMANCE CURVES
Tcase = 25 °C, Full Load, Unless Otherwise Specified
4.1 EFFICIENCY PERFORMANCE CURVES
4.1.1 VHR30-2805D Efficiency (%) vs. Output Power (W)
4.1.2 VHR30-2812D Efficiency (%) vs. Output Power (W)
4.1.3 VHR30-2815D Efficiency (%) vs. Output Power (W)
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
6
VHR30-2800D SERIES DATASHEET
4.0 PERFORMANCE CURVES (CONTINUED)
4.2 CROSS REGULATION CURVES
4.2.1 VHR30-2805D -Vout (V) vs. -Iout (A)
4.2.2 VHR30-2812D -Vout (V) vs. -Iout (A)
4.2.3 VHR30-2815D -Vout (V) vs. -Iout (A)
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
7
VHR30-2800D SERIES DATASHEET
5.0 MECHANICAL OUTLINES AND PINOUT
Standard Metal Package:
.245in 0.015 6.22mm 0.38
.400in 10.16mm MAX
1.885in 47.88mm MAX
1.550in 39.37mm
0.165in 4.19mm
2X MOUNTING HOLE
0.004
+
0.125in
0.003
-
+
0.10
0.08
3.18mm
-
BASEPLATE SURFACE
8X SEAL
0.650in 16.51mm
0.500in 12.70mm
0.450in 11.43mm
0.350in 8.89mm
5
4
0.083in 0.002
2.10mm 0.05
6
7
8
3
2
8X PIN
0.039in 0.002
1mm 0.05
0.200in 5.08mm
0.100in 2.54mm
0in 0mm
0.225in 5.72mm
0.250in 6.35mm
1
1.
2.
3.
4.
Case temperature is measured on the center of the baseplate surface.
Materials: Baseplate (Aluminum, conductive conversion coating); Cover (Nickel Plated); Pins (Copper, gold over nickel plating)
Mounting holes are not threaded. Recommended fastener is 4-40
This Package is not hermetic. VPT offers a wide range of hermetic products. Please contact VPT for details if hermetic products are required.
Pin Function
Pin Function
1
2
3
4
INHIBIT
5
6
7
8
28VIN
CASE
+VOUT
OUTCOM
-VOUT
SYNC
INCOM
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
8
VHR30-2800D SERIES DATASHEET
6.0 PACKAGE PIN DESCRIPTION
Pin
Function
Description
This is an open collector input. Logic Low = Disabled Output. Connect the inhibit pin to input common to disable the output.
Unconnected, open collector or open drain = Enabled Output.
1
2
3
4
5
6
7
8
INHIBIT
CASE
Case Connection.
SYNC
Frequency Synchronization Signal Input. TTL squarewave, 5 Vpp, 20 – 80% duty cycle, internally capacitively coupled.
INCOM
28VIN
Input Return Connection.
Positive Input Voltage Connection.
Positive Output Voltage Connection.
Output Return Connection.
+VOUT
OUTCOM
-VOUT
Negative Output Voltage Connection.
7.0 ENVIRONMENTAL SCREENING
Screening
Condition
Internal Visual
IPC-A-610, Class 3
Final Electrical
External Visual
100% at 25 °C
Internal Procedure
8.0 ORDERING INFORMATION
VHR30-
28
05
D
1
2
3
4
(1)
(2)
(3)
(4)
Product
Series
Nominal Input
Voltage
Output Voltage
Number of
Outputs
VHR30-
28
28 Volts
05
12
15
±5 Volts
±12 Volts
±15 Volts
D
Dual
Please contact your sales representative or the VPT Inc. Sales Department for more information concerning additional
environmental screening and testing, different input voltage, output voltage, power requirements, and source inspection.
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
9
VHR30-2800D SERIES DATASHEET
9.0 CONTACT INFORMATION
To request a quotation or place orders please contact your sales representative or the VPT, Inc. Sales Department at:
Phone:
Fax:
(425) 353-3010
(425) 353-4030
E-mail:
vptsales@vptpower.com
All information contained in this datasheet is believed to be accurate, however, no responsibility is assumed for possible errors or
omissions. The products or specifications contained herein are subject to change without notice. VPT, its logo and tagline are
registered trademarks in the U.S. Patent and Trademark Office.
10.0 ADDITIONAL INFORMATION
Visit the VPT website for additional technical resources, including:
Product Literature
Application Notes and White Papers
Technical Video Labs
Additional Products For Avionics/Military,
Hi-Temp, Hi-Rel COTS, and Space Applications
3.0
SALES INFORMATION: phone (425) 353-3010 • fax (425) 353-4030 • vptsales@vptpower.com • www.vptpower.com
10
相关型号:
©2020 ICPDF网 联系我们和版权申明