PSAE-800-36 [WALL]
AC/DC Switching Power Supplies;型号: | PSAE-800-36 |
厂家: | WALL INDUSTRIES,INC. |
描述: | AC/DC Switching Power Supplies |
文件: | 总8页 (文件大小:469K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
FEATURES
• RoHS Compliant
• Programmable Output Voltage (0~105%)
• Programmable Output Current (0~105%)
• Power OK Signal (Power Good, Logic Low)
• Remote ON/OFF, Remote Sense Functions
• Universal Input Voltage Range: 90-264VAC
• Single Outputs Ranging from 12~60VDC
• +5V/0.5A or +8V/0.3A Auxiliary Output
Selectable by User
• Active PFC > 0.95 at 230VAC
• Up to 804 Watts Output Power
• High Efficiency up to 93%
• 4242VDC I/O Isolation
• Constant Current Limiting
• Intelligent LED Indicators
• Optional RS232 Function
• Built-in I2C Serial Data Bus
• 1U Profile, High Power Density
Size:
9.80 x 5.00 x 1.61 inches
(249.0 x 127.0 x 41.0 mm)
• Forced Current Sharing at Parallel Operation
• UL 60950-1, 2nd edition, TUV EN60950-1:
• Protection: OLP, OVP, OTP, Fan Failure
2006+A11 Approvals
DESCRIPTION
The PSAE800 series of AC/DC switching power supplies provides up to 804 Watts of output
power in a 9.80” x 5.00” x 1.61” enclosed case. This series consists of single output models
ranging from 12~60VDC with an input voltage range of 90~264VAC. Standard features
include high efficiency up to 93%, active PFC, programmable output voltage and output
current, remote on/off, remote sense, power OK signal, and internal ball bearing fan. This
series also has over voltage, over load, and over temperature protection. All models are
RoHS compliant and have UL 60950-1, 2nd edition and TUV EN60950-1: 2006+A11 safety
approvals.
MODEL SELECTION TABLE
Model Number
PSAE-800-12
PSAE-800-15
PSAE-800-24
PSAE-800-30
PSAE-800-36
PSAE-800-48
Input Voltage
Output Voltage
12 VDC
Output Current
66.7A
Output Power
800W
Ripple & Noise (1)
120mVp-p
150mVp-p
240mVp-p
300mVp-p
360mVp-p
480mVp-p
600mVp-p
Efficiency
89%
15 VDC
53.4A
801W
90%
24 VDC
33.5A
804W
92%
90~264 VAC
30 VDC
26.7A
801W
92%
36 VDC
22.3A
802.8W
801.6W
804W
92%
48 VDC
16.7A
92%
PSAE-800-60
NOTES
60 VDC
13.4A
93%
1. Ripple & noise is measured at 20MHz limited bandwidth and using a 12" twisted pair-wire terminated with a 0.1µF & 47µF
capacitors in parallel.
2. For voltages near the low end of the input voltage range, see the derating curve for the power supply output rating.
3. When in parallel operation only one unit might operate if the total output load is less than 5% of the rated load condition.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-
confirmed that it still meets EMC directives.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 1 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
SPECIFICATIONS: PSAE800 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
Input Voltage
TEST CONDITIONS
Min
Typ
Max
Unit
See Note 2
90
47
264
63
VAC
Hz
Input Frequency
At 100VAC and full load
At 230VAC and full load
At 115VAC and cold start
At 230VAC and cold start
At 115VAC and full load
At 230VAC and full load
9.3
4.7
AC Current
A
A
30
Inrush Current
Power Factor
60
0.98
0.95
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Voltage Tolerance
Voltage Adjustability
Line Regulation
Includes set-up tolerance, line regulation, and load regulation
Typical adjustment by potentiometer (VR1)
Low Line to High Line
-2.0
-5.0
-1.0
-1.0
+2.0
+5.0
+1.0
+1.0
%
%
%
%
Load Regulation
Output Power
0% to 100% full load
See Table
Output Current
See Table
See Table
Ripple & Noise (20MHz BW)
Hold-up Time
Measured with 0.1µF and 47µF capacitors in parallel
At 230VAC and full load
full load
14
ms
ms
Setup Time
800
100
Rise Time
full load
ms
Temperature Coefficient
PROTECTION
Over Voltage Protection (see page 4) Protection type: latch-style. Recovery after reset AC power ON or inhibit
0~50°C
-0.02
+0.02
%/°C
Variable OVP, 120% 7% Vout
105% rated output power
Over Load Protection
Over Temperature Protection
GENERAL SPECIFICATIONS
Efficiency
Protection type: constant current limiting
Protection type: shutdown output voltage (auto-recovery after temp. goes down)
85°C 5°C detect on heatsink of sec. side
See Table
Input to Output
4242VDC (3000VAC)
2121VDC (1500VAC)
707VDC (500VAC)
Isolation Voltage
Input to FG
Output to FG
Isolation Resistance
Leakage Current
Input to output, input to FG, output to FG; 500VDC
At 240VAC
100
MΩ
mA
1
FUNCTIONS
Auxiliary Power
+5V/0.5A or +8V/0.3A auxiliary output selectable by user
External switch or NPN transistor to turn ON/OFF
Remote ON/OFF Control
Power OK Signal
Open drain signal low when PSU turns on; sink current: 20mA max.; drain voltage: 40V max.
Adjustment of output voltage is between 0~105% of rated output
Adjustment of output current is between 0~105% of rated output
See page 6
Output Voltage Trim
Output Current Trim
Parallel Operation (Current Sharing)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
With derating (see derating curve)
Non-condensing
-20
-40
20
+60
+85
90
°C
°C
% RH
% RH
10
95
Cooling
Controlled by power rating and temperature (internal ball bearing fan)
Vibration
10~500Hz, 2G 10 min./1 cycle, period for 60 min. each along X, Y, Z axes. Compliance to IEC 68-2-6, IEC 68-2-64
PHYSICAL SPECIFICATIONS
Weight
3.75 lbs (1700g)
Dimensions (W x H x D)
SAFETY & EMC (See Note 4)
Safety Approvals
9.80 x 5.00 x 1.61 inches (249.0 x 127.0 x 41.0 mm)
UL 60950-1, 2nd edition, TUV EN60950-1: 2006+A11
EN55022: 2006+A1:2007 Class B, EN61204-3:2000, EN61000-6-3: 2007
EMI (Conduction & Radiation)
Harmonic Current
EN61000-3-2: 2006+A2: 2009 Class A, EN61000-3-3: 2008
EMS Immunity
EN55024: 1998+A1: 2001+A2: 2003 light industry level, criteria A, EN61204-3: 2000, EN61000-6-1: 2007
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 2 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
MECHANICAL DRAWING
Unit: inches [mm]
1.61 [40.9]
9.80 [249.0]
+V
-V
M6
3-M4 L=0.157 [4]
VR1
LED
Air!ow
Direction
3
2
1
7.80 [198.0]
1.46 [37.0] 1.06 [26.9]
0.55 [14.0]
6-M4 (Both Sides) L=0.236 [6]
0.81 [20.5]
0.45 [11.5]
0.98 [25.0]
0.32 [8.0]
8.70 [221.0]
AC Input Terminal
Pin No. Function
Control Pin Number Assignment (CN2)
Description Pin No. Function
Pin No. Function
Description
Inhibit ON/OFF (+)
+5V/0.5A, +8V/0.3A Auxiliary Power
Inhibit ON/OFF (-)
1
2
3
ACL
1
2
NC
NC
For RS232 Receiver Function
For RS232 Transmission Function
+5V/0.5A, +8V/0.3A Auxiliary Power
Ground
13
14
15
16
17
18
19
20
21
22
23
24
EN+
AUX
EN-
ACN
3
AUX
GND
SCL
4
GND
PAR
VSET
POK
GND
VS-
Ground
5
Serial Data used in the I2C Interface
Serial Data used in the I2C Interface
+5V/0.5A, +8V/0.3A Auxiliary Power
Ground
Parallel Operation Current Sharing
AUX Output Set
6
SDA
AUX
GND
VCI
7
Power OK
8
Ground
9
V Program
Remote Sense (-)
10
11
12
GND
ACI
Ground
VO-
Negative Output Voltage
Resmote Sense (+)
Positive Output Voltage
I Program
VS+
VO+
GND
Ground
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 3 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
DERATING CURVES
Load vs Ambient Temperature
Load vs Input Voltage
Ta=25°C
100
100
80
60
40
20
90
80
70
60
50
40
-20
0
10
20
30
40
50
60
70
90
264
100
110
120
Ambient Temperature (°C)
Input Voltage (VAC)
CURVES
CMD vs Output Curve
VCI vs OVP Curve
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 4 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
LED STATUS
LED
LED Signal
Status
Power OK (Local Mode)
Power OK (Remote Mode)
Power Standby
Solid (Green)
Solid (Orange)
Slow Blink (Green)
Fast Blink (Red)
Solid (Red)
Over Voltage Protection (OVP)
Over Load Protection (OLP)
Over Temperature Protection (OTP)
Fan Failure
Slow Blink (Red)
Intermittent Blink (Red)
Interlace Blink (Red)
Power Failure
* Local mode: Use ACI/VCI to control output current and voltage
Remote Mode: Use RS232 or I2C command to control output current and voltage
REMOTE ON/OFF
(1) Using Internal 5V Auxiliary Source
(2) ON/OFF Control by NPN Transistor
(3) Using External Voltage Source
AUX
AUX
AUX
SW
2KΩ
EN+
2KΩ
EN+
2KΩ
EN+
SW
AUX
AUX
AUX
AUX
EN-
EN-
Tr
EN-
Ctrl
GND
GND
GND
GND
OFF Power OFF
ON Power ON
L
Power OFF
Power ON
OFF Power OFF
ON Power ON
sw
Ctrl
sw
H
Default setting
POWER OK SIGNAL
* Place an additional capacitor to have a better performance of auxiliary power
operation.
P.OK
Good
Failure
* The grounding of “AUX” power should be connected to “GND” port. If “V-“ is
connected as Grounding, make sure to short the GND and V- ports.
DC / DC
5V / 0.5A
8V / 0.3A
Open
5V
8V
(Default Setting)
AUX
Vset
Short to GND
VSET
GND
Internal Circuit
AUX
LOAD
470µF
16V
*
AUX and P.OK Signal
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 5 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
CURRENT SHARING
1) Remote Sense
2) Current Sharing with Remote Sensing
1
2
CN2
NC
NC
AUX
SCL
AUX
VCI
GND
SDA
GND
GND
GND
AUX
GND
ACI
EN+
EN-
PAR VSET
POK
VS-
GND
VO-
VS+
VO+
23
24
Load
1
2
1
2
1
2
1
2
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
ACI
ACI
ACI
ACI
EN+
EN-
EN+
EN-
EN+
EN-
EN+
EN-
PAR VSET
PAR VSET
PAR VSET
PAR VSET
POK
GND
VO-
POK
GND
VO-
POK
GND
VO-
POK
GND
VO-
VS-
VS-
VS-
VS-
VS+
VO+
VS+
VO+
VS+
VO+
VS+
VO+
23
24
23
24
23
24
23
24
3) Local Sense (Default Setting)
4) Current Sharing with Local Sensing
1
2
CN2
NC
AUX
SCL
AUX
VCI
NC
GND
SDA
GND
GND
GND
AUX
GND
ACI
EN+
EN-
PAR VSET
POK
VS-
GND
VO-
Load
VS+
VO+
23
24
1
2
1
2
1
2
1
2
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
NC
AUX
SCL
AUX
VCI
NC
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
GND
SDA
GND
GND
GND
AUX
GND
ACI
ACI
ACI
ACI
EN+
EN-
EN+
EN-
EN+
EN-
EN+
EN-
PAR VSET
PAR VSET
PAR VSET
PAR VSET
POK
GND
VO-
POK
GND
VO-
POK
GND
VO-
POK
GND
VO-
VS-
VS-
VS-
VS-
VS+
VO+
VS+
VO+
VS+
VO+
VS+
VO+
23
24
23
24
23
24
23
24
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 6 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
INSTALLATION INSTRUCTIONS
1. Mounting Directions
1-1 Recommended Standard Mounting Methods
(a)
(b)
(c)
CN2
23
24
1
2
3-M4
L=4mm max.
3-M4
L=4mm max.
3-M4
L=4mm max.
2. Mounting Method
2-1 There are ventilating holes on the front and back side panels. Do not obstruct; allow at least 50mm for airflow
2-2 The maximum allowable penetration for the screw is 4mm. Incomplete threading should not be penetrated.
2-3 Recommended torque of mounting screw: M4 screw: 1.27N • m (13.0kgf • cm)
More than 50mm
More than 50mm
FAN
FAN
Airflow
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 7 of 8
PSAE800 SERIES
Rev B
Wall Industries, Inc.
Up to 804 Watts, AC/DC Switching Power Supplies
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will
provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one
example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its
customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing
support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
ꢀ(603)778-2300
ꢀ(888)597-9255
ꢀ(603)778-9797
E-mail:
Web:
Address:
sales@wallindustries.com
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
07/23/2013
Page 8 of 8
相关型号: