744917227 [WURTH]

WE-KI HC SMD High Current Wire Wound Ceramic Inductor;
744917227
型号: 744917227
厂家: WURTH ELEKTRONIK GMBH & CO. KG, GERMANY.    WURTH ELEKTRONIK GMBH & CO. KG, GERMANY.
描述:

WE-KI HC SMD High Current Wire Wound Ceramic Inductor

文件: 总6页 (文件大小:373K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Dimensions: [mm]  
Recommended Land Pattern: [mm]  
Electrical & Optical Properties:  
Properties  
Test conditions  
Value  
270  
Unit Tol.  
Inductance  
100 MHz  
250 MHz  
@ 20 °C  
ΔT = 20 K  
L
Q
nH  
2ꢀ  
min.  
max.  
1,92  
0,64  
Q-factor  
25  
DC Resistance  
Rated Current  
Self Resonant Frequency  
RDC  
IR  
2.25  
260  
mA max.  
MHz min.  
fres  
1050  
0,3 ±0,1  
1,7 ±0,2  
Scale - 20:1  
Schematic:  
General Information:  
It is recommeded that the temperature of the component does not exceed +125°C under worst  
case conditions  
Operating Temperature  
-40 °C up to +125 °C  
-10 °C up to +40 °C  
Storage Temperature (in original  
packaging)  
Test conditions of Electrical Properties: +20°C, 33ꢀ RH if not specified differently  
Scale - 20:1  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
DESCRIPTION  
74638 Waldenburg  
Germany  
Tel. +49 (0) 79 42 945 - 0  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
001.000  
Valid  
2015-11-10  
eiSos  
1/6  
0603  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  
Typical Inductance vs. Frequency Characteristics:  
Q-Factor vs. Frequency:  
1000  
60  
100  
10  
1
40  
20  
0
10  
100  
1000  
10000  
10  
100  
1000  
10000  
Frequency [MHz]  
Frequency [MHz]  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
DESCRIPTION  
74638 Waldenburg  
Germany  
Tel. +49 (0) 79 42 945 - 0  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
001.000  
Valid  
2015-11-10  
eiSos  
2/6  
0603  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  
P0  
T3  
T
D0  
P2  
W3  
W1  
close to center  
B
C
A0  
W2  
top cover  
tape  
T1  
K0  
P1  
Carrier tape  
Feeding direction  
End  
Start  
Cover tape  
No Component  
min. 160 mm  
Components  
No Component  
min. 100 mm  
Cover Tape  
min. 400 mm  
Packaging is referred to the international standard IEC 60286-3; 2013  
A0  
typ.  
1.2  
B0  
typ.  
1.85  
W
P1  
0,1  
4
T
typ.  
1.02  
T1  
max.  
0.1  
D0  
+0,1  
1.5  
E1  
0,1  
1.75  
E2  
min.  
6.25  
F
G
min.  
1.8  
P0  
0,1  
4
P2  
0,05  
2
Tape  
VPE / packaging unit  
pcs.  
3000  
A
2,0  
178  
B
min.  
1.5  
C
0,8  
13  
D
min.  
20.2  
N
min.  
50  
W1  
+1.5  
8.4  
W2  
max.  
14.4  
W3  
min.  
7.9  
W3  
max.  
10.9  
tolerance  
size  
0,1  
0,05  
3.5  
tolerance  
Tape width  
0603  
8
Paper  
8 mm  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
74638 Waldenburg  
Germany  
165° - 180°  
DESCRIPTION  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
Tel. +49 (0) 79 42 945 - 0  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
Pull-of force  
001.000  
Valid  
2015-11-10  
eiSos  
3/6  
0603  
8 mm  
Tape width  
0,1 N - 1,0 N  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  
Classification Reflow Profile for SMT components:  
Classification Reflow Soldering Profile:  
Profile Feature  
Value  
Ts min 150 °C  
Ts max 200 °C  
Preheat Temperature Min  
Preheat Temperature Max  
Preheat Time ts from Ts min to Ts max  
Ramp-up Rate (TL to TP)  
Tp  
ts  
60 - 120 seconds  
TC –5°C  
tp  
Max. Ramp Up Rate  
3 °C/ second max.  
217 °C  
Max. Ramp Down Rate  
Liquidous Temperature  
TL  
tL  
Time tL maintained above TL  
Peak package body temperature  
Time within 5°C of actual peak temperaure  
Ramp-down Rate (TL to TP)  
Time 25°C to peak temperature  
60 - 150 seconds  
see table below  
20 - 30 seconds  
6 °C/ second max.  
8 minutes max.  
TL  
tL  
Tp  
t p  
Ts max  
Preheat Area  
Ts min  
refer to IPC/ JEDEC J-STD-020E  
tS  
Package Classification Reflow Temperature:  
Volume mm³  
<350  
Volume mm³  
350-2000  
Volume mm³  
>2000  
Properties  
PB-Free Assembly | Package Thickness < 1.6 mm  
260 °C  
260 °C  
250 °C  
245 °C  
260 °C  
245 °C  
245 °C  
25  
PB-Free Assembly | Package Thickness 1.6 mm - 2.5 mm 260 °C  
Time 25°C to Peak  
PB-Free Assembly | Package Thickness ≥ 2.5 mm  
250 °C  
Time  
refer to IPC/ JEDEC J-STD-020E  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
DESCRIPTION  
74638 Waldenburg  
Germany  
Tel. +49 (0) 79 42 945 - 0  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
001.000  
Valid  
2015-11-10  
eiSos  
4/6  
0603  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  
Cautions and Warnings:  
The following conditions apply to all goods within the product series of WE-KIHC of  
Würth Elektronik eiSos GmbH & Co. KG:  
General:  
All recommendations according to the general technical specifications of the data sheet have to be complied with.  
The usage and operation of the product within ambient conditions, which probably alloy or harm the wire isolation, has to be avoided.  
If the product is potted in customer applications, the potting material might shrink during and after hardening. The product is exposed to the  
pressure of the potting material with the effect that the core, wire and termination is possibly damaged by this pressure and so the  
electrical as well as the mechanical characteristics are endangered to be affected. After the potting material is cured, the core, wire and  
termination of the product have to be checked if any reduced electrical or mechanical functions or destructions have occurred.  
The responsibility for the applicability of customer specific products and use in a particular customer design is always within the authority of  
the customer. All technical specifications for standard products do also apply to customer specific products.  
Cleaning agents that are used to clean the customer application might damage or change the characteristics of the component, body, pins  
or termination.  
Direct mechanical impact to the product shall be prevented as the core material could flake or in the worst case it could break.  
Product specific:  
Follow all instructions mentioned in the data sheet, especially:  
The soldering profile has to be complied with according to the technical reflow soldering specification, otherwise this will void the  
warranty.  
All products shall be used before the end of the period of 12 months based on the product date code, if not a 100ꢀ solderability can´t  
be ensured.  
Violation of the technical product specifications such as exceeding the nominal rated current will void the warranty.  
Strong forces might have the effect to damage the coplanarity of the electrical connection (pins), will restrain the soldering and void the  
warranty.  
Please notice that the recommended thickness of the soldering paste is 120 µm.  
The general and product specific cautions comply with the state of the scientific and technical knowledge and are believed to be accurate  
and reliable; however, no responsibility is assumed for inaccuracies or incompleteness.  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
DESCRIPTION  
74638 Waldenburg  
Germany  
Tel. +49 (0) 79 42 945 - 0  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
001.000  
Valid  
2015-11-10  
eiSos  
5/6  
0603  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  
6. Product Life Cycle  
Important Notes  
Due to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a  
standard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage  
about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be  
available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product  
availability expectancy before or when the product for application design-in disposal is considered. The approach named above does not  
apply in the case of individual agreements deviating from the foregoing for customer-specific products.  
The following conditions apply to all goods within the product range of Würth Elektronik  
eiSos GmbH & Co. KG:  
1. General Customer Responsibility  
Some goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain  
application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the  
areas, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The  
responsibility for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this  
fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product  
characteristics described in the product specification is valid and suitable for the respective customer application or not.  
7. Property Rights  
All the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as  
well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth  
Elektronik eiSos GmbH & Co. KG. Würth Elektronik eiSos GmbH & Co. KG does not warrant or represent that any license, either expressed or  
implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination,  
application, or process in which Würth Elektronik eiSos GmbH & Co. KG components or services are used.  
2. Customer Responsibility related to Specific, in particular Safety-Relevant Applications  
8. General Terms and Conditions  
It has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime  
cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.  
In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable  
design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic  
component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be  
downloaded at www.we-online.com.  
Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth  
Elektronik eiSos Group, last version available at www.we-online.com.  
3. Best Care and Attention  
Any product-specific notes, cautions and warnings must be strictly observed. Any disregard will result in the loss of warranty.  
4. Customer Support for Product Specifications  
Some products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve  
specific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales  
person in charge should be contacted who will be happy to support in this matter.  
5. Product R&D  
Due to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the  
Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries  
regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the  
customer as per Section 1 and 2 remains unaffected.  
CREATED  
CHECKED  
GENERAL TOLERANCE  
PROJECTION  
METHOD  
Würth Elektronik eiSos GmbH & Co. KG  
EMC & Inductive Solutions  
KaS  
HBH  
DIN ISO 2768-1m  
Max-Eyth-Str. 1  
DESCRIPTION  
74638 Waldenburg  
Germany  
Tel. +49 (0) 79 42 945 - 0  
WE-KI HC SMD High Current Wire  
Wound Ceramic Inductor  
ORDER CODE  
www.we-online.com  
eiSos@we-online.com  
744917227  
SIZE  
REVISION  
STATUS  
DATE  
BUSINESS UNIT  
PAGE  
001.000  
Valid  
2015-11-10  
eiSos  
6/6  
0603  
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH  
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety  
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY