AEK40 [XPPOWER]

AC-DC Power Supplies;
AEK40
型号: AEK40
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies

文件: 总4页 (文件大小:547K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies  
XP Power  
AEK40 Series  
40 Watts  
• Energy Efficiency Level VI  
• European CoC Tier 2  
• <0.075 W Standby Power  
• Single Outputs 5 to 48 V  
• 0 °C to 60 °C Operation  
• Universal Input  
• 3 Year Warranty  
Dimensions:  
AEK40:  
4.21 x 1.85 x 1.19” (107.0 x 47.0 x 30.1 mm)  
Models & Ratings  
Output Power  
Output Voltage  
Output Current  
Total Regulation  
Ripple & Noise(3)  
Efficiency(1)  
Model Number  
25 W  
5.0 V  
12.0 V  
15.0 V  
18.0 V  
24.0 V  
48.0 V  
5.00 A  
3.33 A  
2.67 A  
2.22 A  
2.08 A  
1.04 A  
50 mV  
100 mV  
100 mV  
100 mV  
100 mV  
100 mV  
85.9%  
88.5%  
88.5%  
88.0%  
88.0%  
88.0%  
AEK40US05  
AEK40US12  
AEK40US15  
AEK40US18  
40 W  
50 W  
5%  
(2)  
AEK40US24  
(2)  
AEK40US48  
Notes  
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load  
and 230 VAC input.  
2. No load input power is <0.15 W.  
3. Pk Pk value measured with 20 MHz bandwidth and 0.47 µF ceramic capacitor.  
Mechanical Details  
1.19 (30.1)  
0.02 (0.5)  
4.21 (107.0)  
AC INPUT  
IEC320-C14 INLET  
Notes  
1. All dimensions shown in inches (mm).  
2. Weight: 0.38 lbs (190 g) approx.  
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length  
which is 2” ( 50 mm)  
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +  
and outer shell - polarity.  
5. Cable length: 5 & 12 V: 48” (1220 mm) 16 AWG  
Others: 48” (1220 mm) 18 AWG  
www.xppower.com  
1
AC-DC Power Supplies  
AEK40 Series  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
264  
Units  
Notes & Conditions  
Input Voltage  
90  
47  
VAC  
Input Frequency  
Input Current  
Inrush Current  
Leakage Current  
No Load Input Power  
Input Protection  
63  
Hz  
A
A
mA  
mW  
0.9/0.52  
Measured at 100 VAC/240 VAC  
230 VAC, cold start at 25 °C  
240 VAC, 60 Hz  
110  
0.75  
75  
150 mW for 24 V and 48 V models  
T2.0A/250 VAC internal fuse in line  
Output  
Characteristic  
Min.  
Typ.  
Max.  
Units  
Notes & Conditions  
Output Voltage  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Hold Up Time  
5
48  
2
VDC  
%
See Models and Ratings table  
At 60% load  
No minimum load required  
2
s
12  
ms  
%
%
Full load and 115 VAC  
Line Regulation  
Load Regulation  
1
4
From minimum to maximum input voltage at full load  
Load regulation measured from 10% to 100% load  
Maximum deviation, recovering to less than 1% within  
500 µs for 25% step load  
Transient Response  
5
%
Ripple and Noise  
mV pk-pk  
See Models and Ratings table  
Overshoot  
5
%
%
At turn on / turn off  
Overload Protection  
Short Circuit Protection  
Temperature Coefficient  
110  
150  
Trip and restart (hiccup), auto resetting  
0.04  
%/°C  
Environmental  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Operating Temperature  
Cooling  
0
+60  
°C  
Derate from 100% load at 40 °C to 67% load at 60 °C  
Natural convection  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
0
-40  
95  
+85  
5000  
%RH  
°C  
m
Non-condensing  
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes  
Vibration  
IEC68-2-6, 10-500 Hz, 5 g 10 mins/sweep, 60 mins for each of 3 axes  
Derating Curve  
100  
80  
60  
40  
20  
60  
0
40  
Ambient Temperature (ºC)  
www.xppower.com  
2
AC-DC Power Supplies  
AEK40 Series  
General  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
%
Notes & Conditions  
Efficiency  
88  
See Models and Ratings table and curves.  
Isolation: Input to Ground  
Isolation: Input to Output  
Isolation: Output to Ground  
Switching Frequency  
Power Density  
1500  
3000  
500  
VAC  
VAC  
VDC  
kHz  
65  
3
4.3  
W/in  
Mean Time Between Failure  
Weight  
100  
kHrs  
lb (g)  
MIL-HDBK-217F at 25 °C GB  
0.38 (190)  
Efficiency Curves  
AEK40US12  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac input  
230Vac input  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
AEK40US24  
100%  
90%  
80%  
70%  
60%  
50%  
115Vac input  
230Vac input  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
EMC: Emissions  
Phenomenon  
Standard  
Test Level  
Notes & Conditions  
Conducted & Radiated  
Emissions  
Harmonic Current  
Voltage Flicker  
EN55022  
EN61000-3-2  
EN61000-3-3  
Level B  
Class A  
www.xppower.com  
3
AC-DC Power Supplies  
AEK40 Series  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
Criteria  
Notes & Conditions  
ESD  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
8 kV Air, 6 kV contact  
3 V/m  
A
A
A
A
A
Radiated  
EFT/Burst  
Surge  
Conducted  
Magnetic Fields  
2
Installation Class 3  
3 V  
3 A/m  
A
Dip: 30% 10 ms  
Dip: 60% 100 ms  
Int: 100% 5000 ms  
A
A/B  
B
High Line/Low Line  
Dips and Interruptions  
EN61000-4-11  
Safety Approvals  
Safety Agency  
Safety Standard  
UL60950-1  
Notes & Conditions  
UL  
TUV  
CB  
EN60950-1  
IEC60950-1  
Mechanical Details  
1.19 (30.1)  
4.21 (107.0)  
0.02 (0.5)  
AC INPUT  
IEC320-C14 INLET  
Notes  
1. All dimensions shown in inches (mm).  
2. Weight: 0.38 lbs (190 g) approx.  
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length  
which is 2” ( 50 mm)  
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +  
and outer shell - polarity.  
5. Cable length: 5 & 12 V: 48” (1220 mm) 16 AWG  
Others: 48” (1220 mm) 18 AWG  
www.xppower.com  
06 Feb 17  

相关型号:

AEK40US05

AC-DC Power Supplies
XPPOWER

AEK40US12

AC-DC Power Supplies
XPPOWER

AEK40US15

AC-DC Power Supplies
XPPOWER

AEK40US18

AC-DC Power Supplies
XPPOWER

AEK40US24

AC-DC Power Supplies
XPPOWER

AEK40US48

AC-DC Power Supplies
XPPOWER

AEK60

AC-DC Power Supplies
XPPOWER

AEK60US12

AC-DC Power Supplies
XPPOWER

AEK60US15

AC-DC Power Supplies
XPPOWER

AEK60US18

AC-DC Power Supplies
XPPOWER

AEK60US24

AC-DC Power Supplies
XPPOWER

AEK60US48

AC-DC Power Supplies
XPPOWER