DSA240PS48 [XPPOWER]
Selectable Overload Characteristic;型号: | DSA240PS48 |
厂家: | XP POWER LIMITED |
描述: | Selectable Overload Characteristic |
文件: | 总5页 (文件大小:712K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
DSA240 Series
240 Watts
• Ultra Slim Design
xxx Series
• 150% Peak Load for 3 seconds
• Ambient Operation from -25 °C to +70 °C
• High Efficiency – Up to 92%
• Selectable Overload Characteristic
• Selectable Remote Inhibit or Enable
• 3 Year Warranty
Dimensions:
DSA240:
4.64 x 4.93 x 2.59” (117.8 x 125.2 x 65.8 mm)
Models & Ratings
Output Voltage
Output Power
240 W
Output Voltage Trim(3) Output Current
Peak Load(2)
15.0 A
Typical Efficiency(1)
Model Number
DSA240PS24
DSA240PS48
24 V
48 V
23.52-25.92 V
47.04-51.84 V
10 A
5 A
91%
92%
240 W
7.5 A
Notes
1. Typical efficiency at 230 VAC and full load.
2. Peak load is for a maximum of 3 s, see Application Notes. Average power is not to exceed nominal output power.
3. Output current should be limited so that nominal output power is not exceeded.
Mechanical Details
4.636 (117.75)
17
1
6
Pin Connector
DC O/P
+V -V +RC -RC DC
OK
Conn Pin
Designation
Ground
L
VOUT ADJ.
ON
1
AC
2
I/P
3
1
2
N
OCP Mode
RC Mode
1
2
3
4
5
6
+Vout
-Vout
+RC
-RC
DC OK
DC OK
DSA240
www.xppower.com
DC
O/P
L
N
AC I/P
2.591 (65.8)
65.80
www.xppower.com
1
AC-DC Power Supplies
DSA240 Series
Input
Characteristic
Minimum
Typical
Maximum
264
Units
VAC
Hz
Notes & Conditions
Input Voltage - Operating
Input Frequency
90
47
50/60
0.95
63
Power Factor
At 230 VAC. Conforms to EN61000-3-2 Class A
115/230 VAC
Input Current - Full Load
Inrush Current
2.5/1.3
A
A
33/65
1.0
At 115/230 VAC
Earth Leakage Current
Input Protection
mA
At 264 VAC, 60 Hz
T5.0 A / 250 V internal in-line fuse
Output
Characteristic
Minimum
Typical
Maximum
Units
VDC
%
Notes & Conditions
Output Voltage - V1
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
24
48
1
See Models and Ratings table
At 100% load
-2/+8
%
See Models and Ratings table
No minimum load required
0
A
Start Up Delay
1.0
50
s
Start Up Rise Time
Hold Up Time
ms
ms
%
20
At full load and 115 VAC
Line Regulation
0.5
1
Load Regulation
%
Recovery within 1% in less than 2 ms
for a 50% step load change at 0.2 A/µs
Transient Response - V1
Ripple & Noise
4
1
%
Measured at 20 MHz bandwidth with 0.1 µF ceramic
capacitor and 47 µF electrolytic
% pk-pk
28
56
33
65
V
V
24 V model
Overvoltage Protection
Overload Protection
48 V model
%
See Application Notes
Trip & restart (hiccup mode) for 5 cycles then latch.
Recycle AC to reset.
Short Circuit Protection
Thermal Protection
Temperature Coefficient
Remote On/Off
95 ( 5)
0.03
°C
Measured on internal heatsink auto recovery
%/˚C
Selectable as Enable or Inhibit using front panel switch
General
Characteristic
Minimum
91
Typical
Maximum
Units
Notes & Conditions
Efficiency
92
%
See Models & Ratings table
3000
1500
500
VAC
VAC
VAC
kHz
Isolation: Input to Output
Input to Ground
Output to Ground
100
Switching Frequency
DC OK Signal
PFC & Main converter
Volt free contacts rated at 60 VDC/0.3 A, 30 VDC/1.0 A or 30 VAC/0.5 A (resistive load)
Green LED to indicate output on.
Output LED
Mean Time Between Failure
Weight
>150
kHrs
lb (g)
MIL-HDBK-217F, +25 °C GB
1.9 (860)
www.xppower.com
2
AC-DC Power Supplies
DSA240 Series
Environmental
Characteristic
Minimum
-25
Typical
Maximum
Units
°C
Notes & Conditions
Operating Temperature
Storage Temperature
Cooling
+70
+85
See derating curve in Application Notes
-40
°C
Natural convection
Non-condensing
Operating Humidity
Operating Altitude
20
95
%RH
m
3000
IEC68-2-27, 4 g, 22 ms half sine, 3 times in each of
6 axes
Shock
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep. 60 mins
for each of 3 axes
Vibration
EMC: Emissions
Phenomenon
Conducted
Standard
Test Level
Criteria
Notes & Conditions
EN55022
EN55022
Class B
Class B
Class A
Radiated
Harmonic Current
Voltage Fluctuations
EN61000-3-2
EN61000-3-3
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
Contact
Air Discharge
6 kV
ESD Immunity
EN61000-4-2
A
8 kV
Radiated Immunity
EFT/Burst
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
10 V/m
A
A
3
Surges
Installation class 3
A
Conducted
10 V
4
A
Magnetic Fields
A
Dip: 30%, 10 ms
A
Dips and Interruptions
EN55024
Dip: 60%, 100 ms
A/B
B
High Line/Low Line
Dip: 100%, 5000 ms
Safety Approvals
Safety Agency
Safety Standard
UL508
Notes & Conditions
UL
Industrial Control Equipment
Information Technology
Information Technology
TUV
CB
EN60950-1 A12:2011
IEC60950-1 +A1:2009
www.xppower.com
3
AC-DC Power Supplies
DSA240 Series
Mechanical Details
4.636 (117.75)
17
1
6
Pin Connector
DC O/P
+V -V +RC -RC DC
OK
Conn Pin
Designation
Ground
L
VOUT ADJ.
ON
1
2
3
1
2
3
4
5
6
AC
I/P
1
2
N
OCP Mode
RC Mode
+Vout
-Vout
+RC
-RC
DC OK
DC OK
DSA240
www.xppower.com
DC
O/P
L
N
AC I/P
2.591 (65.8)
65.80
Notes
1. All dimensions in inches (mm)
2. Weight: 1.916 lbs (860g)
4. Screw terminal: 10-24 AWG cables size.
5. Connection screw maximum torque: Input: 4.4lbs-in (0.5 Nm), Output: 7.0 lbs-in (0.79 Nm).
3. Tolerance: 0.02 in ( 0.5 mm)
Application Notes
Derating Curves
100
90
80
70
60
50
40
150
112.5
100
50
For typ. 3sec
Continuous
40
(Vertical)
-25
0
10
20
30
40
50
60
70
90
100
110
135
230 264Vac
Ambient Temperature (°C)
Input Voltage(V)
DC OK
5
DCOK
Open = Output fail, if voltage drops below 45% of nominal
Closed = Output good
Contact Rating: 0.3 A at 60 VDC, 1.0 A at 30 VDC, 0.5 A at 30 VAC.
500 VDC isolation to output.
6
DCOK
www.xppower.com
4
AC-DC Power Supplies
DSA240 Series
Application Notes
Peak Loading
The peak loading and overload characteristics can be programmed into one of two modes by
appropriate selection of the OCP mode switch on the front panel.
OCP Mode switch set to position 1
I
A peak load of up-to 150% can be taken for a given duration. This duration depends on the
percentage of peak load taken and can be determined by graph A below.
T-peak
I-peak
If the load is reduced to less than 100% of nominal either before or at the end of the duration,
then there is a period of recovery needed to allow the power supply to cool down before the
peak load can be re-applied. The time required for recovery depends on the amount of reduction
of load and can be determined by graph B below.
I-recovery
T-recovery
However, if the peak load period exceeds the duration indicated by graph A the output will go
into constant current mode for protection. The constant current value will be 105% of the
nominal rating.
0
T
During constant current operation, if the output voltage should fall below 40% of the rated
voltage then the output will turn off and try to restart for five times before turning off
permanently. Once this has happened, the output will need to be reset by turning the AC mains
off and on again.
A peak load of up-to 150% can be taken for a given duration. This duration depends on the
percentage of peak load taken as described by graph A.
OCP Mode switch set to position 2
I
Once the peak load duration is exceeded, the output will turn off for 3-4 seconds before
automatically restarting.
T-peak
I-peak
GRAPH A
GRAPH B
0
T
3 ~ 4 sec
(Sec.)
(Sec.)
P-eak duration
Recovery duration
24
22
20
18
16
14
12
10
8
6
4
2
0
22
20
18
16
14
12
10
8
6
4
2
0
I-normal
10% 20% 30% 40% 50% 60% 70% 80% 90%
Load (%
110%115%120%125%130%135%140%145%150%
I-peak
Load (%
)
)
Remote Control
The output can be controlled by applying a voltage between
pin 3 of the DC output with respect to pin 4. The effect of the
control is dependant upon the RC switch setting on the front
panel.
Pin 3 Voltage
with respect to Pin 4
Switch Position
Output
ON
1
1
2
2
<0.8 V or Open Circuit
>2.5 V, <9.0 V
OFF
OFF
ON
If the switch is set to position 1 then the output can be
disabled by applying a suitable voltage.
<0.8 V or Open Circuit
>2.5 V, <9.0 V
If the switch is set to position 2 then the output can be
enabled by applying a voltage. In the range of 2.5 V to 9.0 V
limited to 20 mA.
www.xppower.com
23 Feb 15
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明