FCS40 [XPPOWER]
AC-DC Power Supplies;型号: | FCS40 |
厂家: | XP POWER LIMITED |
描述: | AC-DC Power Supplies |
文件: | 总5页 (文件大小:814K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
FCS40 Series
40 Watts
• 40 W Convection Rating
• 2” by 3” Footprint
• Low 1.04” Profile
• High Efficiency
• Medical and ITE Approvals
• Class I & Class II Installations
• High Power Density
• Less than 0.3 W No Load Input Power
• 3 Year Warranty
Dimensions:
The FCS40 series is designed to minimize the no load power consumption and maximize efficiency
to facilitate equipment design to meet the latest environmental legislation. Approved for medical and
ITE applications in either Class I or Class II installations, this range of single output AC-DC power supplies
are packaged in a low profile 1.04” height with a foot print of just 2” by 3”. The FCS40 provides up to
40W convection-cooled over the full 90-264 VAC input range, and operates down to 80 VAC with minimal
FCS40:
2.00 x 3.00 x 1.04” (50.8 x 76.2 x 26.4 mm)
de-rating. The power supply features two AC line fuses and low leakage currents required by medical applications. The low profile, low noise and safety
approvals covering ITE and medical standards allows the versatile FCS40 series to be used in a wide range of applications.
Models & Ratings
Output Power
40 W
Output Voltage
12.0 V
Output Current
3.34 A
Efficiency(1)
82%
Model Number
FCS40US12
FCS40US15
FCS40US18
FCS40US24
FCS40US36
FCS40US48
40 W
40 W
40 W
40 W
15.0 V
18.0 V
24.0 V
36.0 V
2.67 A
2.23 A
1.67 A
1.11 A
85%
85%
85%
84%
40 W
48.0 V
0.83 A
86%
Notes
1. Typical efficiency measured at full load and 230 VAC input.
Mechanical Details
CN1 - Input Connector
3.0 (76.2)
2.7 (69.8)
ø0.134 (ø3.4)
thru in 4 positions
Pin 1
Pin 2
Pin 3
Line
Not Fitted
Neutral
Mates with JST housing VHR-3N and JST
Series SVH-21T-P1.1 crimp terminals
Neutral
Line
2.0
(50.8)
+VE
-VE
2.0
(50.8)
1.7
(44.4)
CN2 - Output Connector
Output Voltage
Adjustment
Pin 1
Pin 2
+Vout
-Vout
Mates with JST housing VHR-2N and JST
Series SVH-21T-P1.1 crimp terminals
1.04
(26.4)
Notes
1. All dimensions shown in inches (mm).
Tolerance: 0.02 (0.5)
2. Weight: 0.19 lbs (86 g) approx.
Mounting hole marked with
be connected to safety earth for class I
applications
must
www.xppower.com
1
AC-DC Power Supplies
FCS40 Series
Summary
Characteristic
Minimum
Typical
Maximum
264
Units
Notes & Conditions
Derate output from 100% at 90 VAC to 90% at 85 VAC and
80% at 80 VAC
Input Range
80
115/230
VAC
No Load Input Power
Efficiency
0.3
W
%
°C
86
230 VAC (see models and ratings table)
See derating curve (fig.1)
Operating Temperature
-25
+70
ITE
IEC60950-1, IEC62368-1, EN62368-1, cUL62368-1
IEC60601-1 Ed 3.1 Including Risk Management, ANSI/AAMI ES60601-1 & CSA C22.2 No.6061-1:08, EN60601-1
Safety Approvals
Medical
Input
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Derate output from 100% at 90 VAC to 90% at 85 VAC and
80% at 80 VAC
Input Voltage - Operating
80
47
115/230
50/60
264
63
VAC
Hz
Input Frequency
Agency approval, 47-63 Hz
EN61000-3-2 class A
115/230 VAC
Power Factor
Input Current - Full Load
Inrush Current
0.8/0.4
A
A
60
270
0.3
264 VAC cold start, 25 ºC
264 VAC/60 Hz
Earth Leakage Current
No load Input Power
Input Protection
µA
W
T3.15 A/250 A, 250 V Internal fuse fitted in line and neutral.
Output - Main Output
Characteristic
Minimum
Typical
Maximum
Units
VDC
%
Notes & Conditions
Output Voltage
12
48
1
See Models and Ratings table
50% load, 115/230 VAC
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
10
0
%
A
No minimum load required
Start Up Delay
1
2
s
Output Rise Time
Hold Up Time
50
ms
ms
%
8.3/20
Min at full load 115/230 VAC
90-264 VAC
Line Regulation
Load Regulation
0.5
1
%
0-100% load.
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
Transient Response
Over/Undershoot
4
5
%
%
Full load
Ripple & Noise
1
% pk-pk
%Vnom
% I nom
20 MHz bandwidth
Overvoltage Protection
115
110
140
180
Continuous trip and restart (hiccup)
Overload Protection
Short Circuit Protection
Temperature Coefficient
Continuous trip and restart (hiccup)
0.05
%/˚C
www.xppower.com
2
AC-DC Power Supplies
FCS40 Series
General
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Efficiency
84
%
115/230 VAC, 100% load
4000
1500
500
VAC
VAC
VAC
2 MOPP
Isolation: Input to Output
Input to Ground
1 MOPP
Output to Ground
1 MOPP at output voltage
3
Power Density
6.4
W/in
Mean Time Between Failure
Weight
500
kHrs
lb(g)
MIL-HDBK-217F, Notice 2 +25 °C GB
0.19 (86.0)
Environmental
Characteristic
Operating Temperature
Storage Temperature
Humidity
Minimum
Typical
Maximum
Units
°C
Notes & Conditions
-25
-40
5
+70
+85
See derating curve, fig.1
°C
95
%RH
m
Non-condensing
ITE/Medical
Operating Altitude
Shock
5000/4000
3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Vibration
Temperature Derating Curve
Figure 1
100
50
0
-25 -20
0
+50
+70
Ambient Temperature (ºC)
Notes
FCS40US12 ripple and noise is <1.5% from -25 °C to 0 °C reducing to <1% after 1 minute warm up.
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted
EN55011/32
Class B
Radiated
EN55011/32
Class A
Class A
Class B with Wurth Electronics 742 700 91 with 4 turns on AC Input
Harmonic Current
Voltage Functions
EN61000-3-2
EN61000-3-3
www.xppower.com
3
AC-DC Power Supplies
FCS40 Series
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
Medical Device EMC
Low Voltage PSU EMC
ESD
IEC60601-1-2
EN61204-3
Ed.4.0 : 2014
as below
High severity level
as below
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
8kV contact, 15kV air
3
A
A
A
A
A
A
A
B
B
B
B
B
A
B
B
B
B
B
A
B
B
B
B
B
A
A
A
A
B
A
A
A
A
B
Radiated
EFT
3
Surge
Installation class 3
Conducted
Magnetic Fields
3
4
Dip 100% (0 VAC), 8.4 ms
Dip 100% (0 VAC), 16.7 ms
Dip 60% (40 VAC), 200 ms
Dip 30% (70 VAC), 500 ms
Dip 20% (80 VAC), 5000 ms
Int 100% (0 VAC), 5000 ms
Dip 100% (0 VAC), 8.4 ms
Dip 100% (0 VAC), 16.7 ms
Dip 60% (40 VAC), 200 ms
Dip 30% (70 VAC), 500 ms
Dip 20% (80 VAC), 5000 ms
Int 100% (0 VAC), 5000 ms
Dip 100% (0 VAC), 10 ms
Dip 100% (0 VAC), 20 ms
Dip 60% (96 VAC), 200 ms
Dip 30% (168 VAC), 500 ms
Dip 20% (192 VAC), 5000 ms
Int 100% (0 VAC), 5000 ms
Dip 100% (0 VAC), 10 ms
Dip 100% (0 VAC), 20 ms
Dip 60% (40 VAC), 100 ms
Dip 30% (70 VAC), 500 ms
Int 100% (0 VAC), 5000 ms
Dip 100% (0 VAC), 10 ms
Dip 100% (0 VAC), 20 ms
Dip 60% (96 VAC), 100 ms
Dip 30% (168 VAC), 500 ms
Int 100% (0 VAC), 5000 ms
25% derating
EN61000-4-11 (100 VAC)
EN61000-4-11 (115 VAC)
EN61000-4-11 (240 VAC)
Dips and Interruptions
20% derating
50% derating
75% derating
EN60601-1-2 (100 VAC)
EN60601-1-2 (240 VAC)
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
CB Report
UL
IEC60950-1:2005, IEC62368-1:2014
Information Technology
Information Technology
Information Technology
cUL62368-1
EN62368-1
LVD
TUV
CE
Safety Agency
Safety Standard
Notes & Conditions
Medical
CB Report
IEC60601-1 Ed 3.1 Including Risk Management
ANSI/AAMI ES60601-1: & CSA C22.2 No.6061-1:08
EN60601-1
UL
CE
Medical
Medical
Isolation
Safety Standard
Notes & Conditions
Primary to Secondary
Primary to Earth
Secondary to Earth
2 x MOPP (Means of Patient Protection)
1 x MOPP (Means of Patient Protection)
1 x MOPP (Means of Patient Protection at output voltage)
IEC60601-1 Ed 3.1
www.xppower.com
4
AC-DC Power Supplies
FCS40 Series
Mechanical Details
3.0 (76.2)
2.7 (69.8)
ø0.134 (ø3.4)
thru in 4 positions
Neutral
2.0
(50.8)
+VE
-VE
Line
2.0
(50.8)
1.7
(44.4)
Output Voltage
Adjustment
1.04
(26.4)
CN1 - Input Connector
CN2 - Output Connector
Pin 1
Line
Pin 1
Pin 2
+Vout
-Vout
Pin 2
Pin 3
Not Fitted
Neutral
Mates with JST housing VHR-2N and
JST Series SVH-21T-P1.1 crimp terminals
Mates with JST housing VHR-3N and JST
Series SVH-21T-P1.1 crimp terminals
Mounting hole marked with
must be
connected to safety earth for class I
applications
Notes
1. All dimensions shown in inches (mm).
Tolerance: 0.02 (0.5)
2. Weight: 0.19 lbs (86 g) approx.
www.xppower.com
22 June 18
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明