0CBF025.XP
更新时间:2025-01-17 08:27:17
品牌:LITTELFUSE
描述:Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1 1/4" fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard.
0CBF025.XP 概述
Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1 1/4" fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard.
0CBF025.XP 数据手册
通过下载0CBF025.XP数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载16 CIRCUIT BREAKERS
Type I – Automatic Reset
Cycles or continuously resets until the fault is corrected. Type I circuit breakers
are typically used to protect circuits which occasionally experience momentary
overloads such as wiper motor and headlamp circuits where a self resetting
device is preferred.
Type II – Modified Reset
Non-cycling, remains in open position while there is power to the circuit. Resets
when ignition is turned off. Type II circuit breakers are typically used in applica-
tions where fuse replacement is objectionable, such as power window, seat
and sunroof circuits.
Type III – Manual Reset
Manually resettable circuit breakers remain in the open position until a button,
lever or other external reset device is manually depressed. Type III circuit
breakers are typically used in applications where a manual reset is desired for
safe diagnosis of a circuit fault.
MINI® Circuit Breakers
CIRCUIT
BREAKERS
MIB
Standard Mini Footprint Circuit Breakers:
Designed to fit in a MINI® Blade fuse block or panel. SAE Type II used primarily as a wiring
harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard.
Bulk
Part No.
US & Canadian
Carded No.
Amp
Rating
MIB
5
MIB 5 BP
MIB 10 BP
MIB 15 BP
MIB 20 BP
MIB 25 BP
MIB 30 BP
5
10
15
20
25
30
MIB 10
MIB 15
MIB 20
MIB 25
MIB 30
Wide Mini Footprint Circuit Breakers:
Direct factory replacement for many domestic OEM applications. Designed to fit either in an ATO®
or MINI® Blade fuse block or panel. Their blade configuration is of the MINI design and fit in a
standard ATO fuse slot or across two MINI slots. Available in either SAE Type I cycling or SAE
Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems.
Conforms to SAE J553C standard.
MMB
Bulk
US
Amp
Part No.
Carded No.
Rating
Typical Application
OEM No.
Cycling Design – Type I
MNB
MMB 15
MMB 20
MMB 15 BP
MMB 20 BP
15
20
Heavy Truck Headlamp
Automotive Headlamp
GM# 12135171
GM# 12135072
Non-Cycling Design – Type II
MNB 10
MNB 15
MNB 20
MNB 25
MNB 10 BP
MNB 15 BP
MNB 20 BP
MNB 25 BP
10
15
20
25
Heavy Duty Truck
Heavy Duty Truck
Automotive/Heavy Truck
Automotive/Heavy Truck
GM# 12135162
GM# 12135164
GM# 12077861
GM# 12077862
GM# 12088575
GM# 12077863
MNB 30
MNB 30 BP
30
Automotive/Heavy Truck
ACB
FCB
Specialty OEM Circuit Breakers
CCB
Direct factory replacement for many domestic OEM vehicles. SAE Type I and Type II
modified reset used primarily as a wiring harness protector in 12 volt DC automotive systems.
Conforms to SAE J553C standard. Designed to mount in ATO style fuse blocks and panels.
Bulk
Part No.
US
Carded No.
Canadian
Carded No.
Amp
Rating
Breaker
Type
Typical Application
OEM No.
ACB 20
ACB 30
ACB 20 BP
ACB 30 BP
ACB 20 CABP
ACB 30 CABP
20
30
Automotive Headlamp
Power Windows,
& Locks
GM# 12040816
GM# 01252240
Chrysler# 83507005
Ford# D9AB-14526-BA
Type I
Type II
FCB 20
CCB 25
FCB 20 BP
CCB 25 BP
FCB 20 CABP
CCB 25 CABP
20
25
Power Windows
Type II
Type I
Headlamps, Power
Windows, Seats
& Locks
Chrysler# 4527053
CIRCUIT BREAKERS
1 7
Universal Circuit Breakers
UCB
Universal Circuit Breakers function identically and have same internal components as
OEM breakers but offer the versatility of snap off terminals for greater flexibility. SAE
Type II modified reset used primarily as a wiring harness protector in 12 volt DC auto-
motive systems. Meets OEM requirements. Conforms to SAE J553C standard.
Designed to mount in ATO style fuse blocks and panels.
Bulk
US
Canadian
Amp
Bulk
US
Canadian
Amp
Part No.
Carded No.
Carded No.
Rating
Part No.
Carded No.
Carded No.
Rating
UCB
UCB 10
UCB 15
5
UCB 5 BP
UCB 10 BP
UCB 15 BP
UCB 5 CABP
UCB 10 CABP
UCB 15 CABP
5
10
15
UCB 20
UCB 25
UCB 30
UCB 20 BP
UCB 25 BP
UCB 30 BP
UCB 20 CABP
UCB 25 CABP
UCB 30 CABP
20
25
30
MRB
Manually Resettable Circuit Breakers
Manually Resettable Circuit Breakers feature an external button to allow resetting of the
device in a safe, convenient manner. SAE Type III manual reset used primarily as a
wiring harness protector in heavy duty 12 volt DC truck systems. Meets OEM require-
ments. Designed to mount in ATO style fuse blocks and panels.
Bulk
Amp
CIRCUIT
Part No.
Rating
Color
OEM #
BREAKERS
MRB 10
MRB 15
MRB 20
MRB 25
MRB 30
10
15
20
25
30
Red
Blue
Gold
Silver
Green
Navistar 2011944C1
Navistar 2011945C1
Navistar 2011946C1
Navistar 2011947C1
Navistar 2011948C1
MCB
MAXI™ Circuit Breakers
Direct factory replacement for many domestic OEM applications. Designed to fit a
MAXI™ Blade fuse block or panel. Available in either SAE Type I cycling or SAE Type II
non-cycling used primarily as a wiring harness protector in 12 volt DC automotive
systems. Meets OEM requirements. Conforms to SAE J553C standard.
MXB
Bulk
US
Canadian
Amp
Part No.
Carded No.
Carded No.
Rating
Typical Application
OEM No.
Cycling Design – Type I
MCB 20
MCB 20 BP
MCB 20 CABP
MCB 30 CABP
20
30
Automotive Headlamp
Automotive Headlamp,
Seats & Wipers
GM# 12065132
GM# 12088553
MCB 30
MCB 30 BP
Non-Cycling Design – Type II
MXB 20
MXB 30
MXB 40
MXB 20 BP
MXB 30 BP
MXB 40 BP
MXB 20 CABP
MXB 30 CABP
MXB 40 CABP
20
30
40
Automotive Power Devices
Heavy Truck & Auto
Cooling Fan
Automotive Power Window
Heavy Truck & Auto Cooling Ford# F6HT-14526-LA
Fan & Power Window
GM# 12077842
Ford# F6HT-14526-KA
GM# 12077843
CBF
Heavy Truck
Ford# F6HT-14526-JA
Fuse Clip Circuit Breakers
Direct replacement for many OEM applications. Designed for glass fuses without
1
4
physical alteration in the system. Fits 1 / " fuse clips. SAE Type II non-cycling used
primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to
SAE J553C standard.
Bulk
US
Canadian
Amp
Bulk
US
Canadian
Amp
Part No.
Carded No.
Carded No.
Rating
Part No.
Carded No.
Carded No.
Rating
CBF 10
CBF 15
CBF 20
CBF 25
CBF 10 BP
CBF 15 BP
CBF 20 BP
CBF 25 BP
CBF 10 CABP
CBF 15 CABP
CBF 20 CABP
CBF 25 CABP
10
15
20
25
CBF 30
CBF 35
CBF 40
CBF 30 BP
CBF 35 BP
CBF 40 BP
CBF 30 CABP
CBF 35 CABP
CBF 40 CABP
30
35
40
813
812
Stud Type Low Voltage (6–12 Volts) Circuit Breakers
SAE Type I automatic reset provides protection in installations where it is not possible to
manually reset a breaker because of location or safety requirements. Used primarily as
a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C
standard. Available with mounting bracket-change part number from 812 to 813, e.g.
813005 ST.
Amp
Rating
Bulk
Part No.
US
Carded No.
Canadian
Carded No.
Amp
Rating
Bulk
Part No.
US
Carded No.
Canadian
Carded No.
5
6
8
10
15
20
812025 ST
812030 ST
812035 ST
812040 ST
812050 ST
N/A
812030 BP
N/A
812040 BP
812050 BP
N/A
812030 CABP
N/A
812040 CABP
812050 CABP
25
30
35
40
50
812005 ST
812006 ST
812008 ST
812010 ST
812015 ST
812020 ST
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
812020 BP
812020 CABP
E
OEM
P
Vis it o u r w e b s it e a t w w w .lit t e lfu s e .c o m
0CBF025.XP 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
0CBF025.Z | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1inch fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J355C standard. | 获取价格 | |
0CBF030.XP | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1 1/4" fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard. | 获取价格 | |
0CBF030.Z | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1inch fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J355C standard. | 获取价格 | |
0CBF035.XP | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1 1/4" fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard. | 获取价格 | |
0CBF035.Z | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1inch fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J355C standard. | 获取价格 | |
0CBF040.XP | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1 1/4" fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard. | 获取价格 | |
0CBF040.Z | LITTELFUSE | Direct replacement for many OEM applications. Designed for glass fuses without physical alteration in the system. Fits 1inch fuse clips. SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J355C standard. | 获取价格 | |
0CBO010.V | LITTELFUSE | Electric Fuse | 获取价格 | |
0CBO012.V | LITTELFUSE | Electric Fuse | 获取价格 | |
0CBO015.V | LITTELFUSE | Electric Fuse | 获取价格 |
0CBF025.XP 相关文章
- 2025-01-17
- 11
- 2025-01-17
- 11
- 2025-01-17
- 10
- 2025-01-17
- 11