Panel Mounted Multi Power Meter 51-UNIT
51U-E0-R1 数据手册
通过下载51U-E0-R1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Panel Mounted Multi Power Meter 51-UNIT
MODEL
MULTI POWER METER
51U
MODEL & SUFFIX CODE SELECTION
110 (4.33)
51U–❑❑❑–❑❑
R
S
T
MODEL
A
V
INPUT (balanced load) *1
R-S
S-T
T-R
110
(4.33)
2
0 : Single-phase / 2-wire, 105V / 5AAC (P. 5/16)
*
x1kW
x10kW
1 : Single-phase / 3-wire, 105V / 210V / 5AAC (P. 7/16)
2 : 3-phase / 3-wire, 220V / 5A AC (P. 10/16)
3 : 3-phase / 3-wire, 110V / 5A AC (P. 10/16)
4 : 3-phase / 4-wire, 110V / √ 3 V / 5A AC (P. 13/16)
DISPLAY ITEMS *3
DISPLAY
126
(4.96)
mm (inch)
Functions & Features
A : A × 3
B : V × 3
C : A × 3, V × 3
D : A × 3, V × 3, kW
E : A × 3, V × 3, kWh
F : A × 3, kW, kWh
G : Hz, PF, kvar
H : V × 3, MV
• Measuring all major factors required for power &
energy management • Transducer combined with
3 displays in one enclosure • RS-485 or DC current
output • Totalized counter values stored in non-vola-
tile memory • Occupying less panel space, requir-
ing fewer connection• Easily replacing standard 110
mm (4 /16 in.) square size, long scale meter • Pa-
rameters are field-selectable
Application Examples
5
0
, V0
J : A × 3, DA, MDA
K : A × 3 or DA, MDA, alarm setpoint
L : Hz, PF, kW
M : PF, kW, kWh
• Updating conventional power meter to a remote
controlled power logger, only with additional trans-
mitter output wiring • Installed within an indus-
trial piece of electrical equipment
N : V × 3, kW, kWh
P : A × 3 or DA or MDA, V × 3, kWh
Q : A × 3, PF, kW
R : A × 3, PF, kvar
S : A × 3 or PF, kW, kWh
T : A × 3, PF, kvarh
U : V × 3, Hz
*1 : Some display items or output types are not selectable
according to the input type. See the detailed selection
guide in the following pages.
*2 : Page No. of the detailed selection guide
*3 : V = Line voltage
kW = Kilowatt
A = Line current
kvar = Kilovar
W : A × 3 or DA or MDA, V × 3, alarm setpoint
X : A × 3, kvar, kvarh
Y : Hz, PF, kWh
OUTPUT
0 : None
1 : 4 – 20mA DC, 3 points
2 : 4 – 20mA DC, 2 points + pulse
3 : 4 – 20mA DC, 2 points + reset input
4 : RS-485 (MsysNet use only. Consult Factory.)
AUXILIARY POWER SUPPLY
M : 85 – 264V AC
PF = Power factor
kWh = Kilowatthours
DA = Demand (current)
MDA = Maximum demand (current)
V0 = Zero-phase voltage
Hz = Frequency
kvarh = Kilovarhours
MV0 = Maximum zero-phase voltage
DEFAULT SETTING
ITEM
DEFAULT SETTING
CT primary rating
5.00A (element S for demand,
time lag 15 min.)
R : 24V DC
P : 110V DC
VT primay rating
GVT tertiary rating
110.0V or 220.0V, same as input rating
110.0V
REMOTE CONTROL
Frequency range
45 – 65 Hz
Pulse out. scaling factor 1 kWh/pulse (kvarh/pulse)
Demand alarm setpoint 100%
1 : 85 – 132V AC or 85 – 143V DC
2 : 20 – 30V DC
RS-485
Address: 01
Transmission speed: 4800 bps
3 : 170 – 264V AC
P. 1 / 16 ES-6481 Rev.9
51U
❑PULSE OUTPUT: totalizing watt in forward flow or
var in lag.
Scaling factor: 0.01, 0.1, 1, 10, 100 kWh/pulse
(default: 1)
Contact rating: 110V DC @0.1A (resistive load)
110V AC @0.1A (resistive load)
Pulse width time: 100 – 150 msec.
(pulse rate ≤12000 pulses/h)
GENERAL SPECIFICATIONS
Construction: 110 mm-square (4 5/16 in.) panel
surface, cylindric body
Connection
Input & auxiliary power: M4 screw terminals
Output: M3 screw terminals
Housing material: plastic (black)
Isolation: input to output to power; not isolated
between analog outputs
❑TRANSMISSION OUTPUT (Multi-Meter Protocol)
Transmission: conform to RS-485, EIA
Transmission distance: 1 kilometer max. (≤31 units)
Scaling:
primary values for CT and VT; tertiary
value for GVT (Inform M-System CT and
VT ratios when ordering.)
5 – 8000A (up to 15000A for Code K)
110 – 77kV
Cable:
shielded twisted-pair cable (CPEV-S 0.9 dia.)
CT:
VT:
Terminator: incorporated
GVT:
63.5 – 190.5V
❑DEMAND ALARM CONTACT OUTPUT
Alarm setpoint: 5 – 100%; adjustable in 0.5% incre-
ments
Contact rating: 110V DC @0.1A (resistive load)
ON resistance: ≤50Ω
Time lag for demand: 0 sec., 30 sec. or 1, 2, 3, 5, 7,
10, 15, 30 min. (default: 15 min.)
Sampling cycle: 400 µsec. (DO NOT connect a
device such like inverters.)
Measurable frequency ranges: 45 – 44 Hz, 55 – 65
Hz, 45 – 65 Hz
Low-end cutout: Display shows 0 for the input less
than the following: approx. 1% for current,
watt and var; approx. 3% for voltage.
I/O RANGES
Proportional to 4 – 20mA DC
DISPLAY ITEMS
Current
RATING
5A
INPUT RANGE
0 – 5A
INPUT
Voltage 1ø / 2w 1 – 2 105V
0 – 150V
❑VOLTAGE INPUT
(must be balanced with 3-phase connection)
Operational range
1ø / 3w 1 – N 105V
2 – N 105V
0 – 150V
0 – 150V
0 – 300V
1 – 2 210V
Voltage, watt, var, zero-phase voltage: 0 – 100% of rat-
ing
3ø / 3w line
110V
220V
0 – 150V
0 – 300V
Power factor: ≥30V
Frequency: ≥30V
3ø / 4w line
110V
0 – 150V
phase 110 / √ 3 V 0 – 150 / √ 3 V
Watt
Var
110V / 5A 0 – 1 kW (0 – 5 kW)
110V / 5A -1 – +1 kW (-0.5 – +0.5 kW)
220V / 5A 0 – 2 kW
Overload capacity: 200% of rating for 60 sec.,
115% for 3 hours
Input burden: 0.3VA/phase
220V / 5A -2 – +2 kW
110V / 5A 0 – lag1 kvar
(0 – lag500 var)
110V / 5A lead1 – lag1 kvar
(lead500 – lag 500 var)
❑CURRENT INPUT
(may be unbalanced with 3-phase connection)
Operational range
220V / 5A 0 – lag2 kvar
220V / 5A lead2 – lag2 kvar
Current, watt, var, demand: 0 – 100% of rating
Power factor: ≥5% of rating
Overload capacity: 4000% of rating for 1 sec., 2000%
for 60 sec., 115% for 3 hours
Power factor
Frequency
––
––
lead 50 – 100 – lag 50 %
45.0 – 55.0 Hz
55.0 – 65.0 Hz
45.0 – 65.0 Hz
Input burden: 0.1VA/phase
Max. zero-phase voltage 63.5V
0 – 86.6V
0 – 150.0V
0 – 259.8V
❑REMOTE CONTROL
110.0V
190.5V
Display switching: same functions as the front
DISPLAY button does; input time ≥0.3
sec., input current 5mA
Reset input: max. zero-phase voltage and demand;
input time ≥0.3 sec., input current 5mA
Demand
5A
5A
0 – 5A, element S
0 – 5A, element S
Maximum demand
Remarks:
1) Values for single-phase connection in brackets.
2) Displays are automatically scaled according to the scal-
ing factor settings for VT and CT.
3) Reverse or lead flow are displayed with the negative (–)
indicator.
OUTPUT
❑CURRENT OUTPUT: 4 – 20mA DC
Load resistance: 500Ω maximum
Specifications subject to change without notice.
P. 2 / 16 ES-6481 Rev.9
INSTALLATION
FRONT PANEL CONFIGURATION
Auxiliary power supply
The front display configuration varies according to
model numbers (display items).
AC:
DC:
operational voltage range 85 – 264V,
50/60 Hz, approx. 5.5VA
operational voltage range for R: 24V ±10%
or P: 85 – 143V; ripple 10% p-p max.;
approx. 5.5W (approx. 230mA at 24V)
A
R
C
S
T
A
V
A
A
R – S
S – T
T – R
D
Operating temperature: -10 to +50°C (14 to 122°F)
Operating humidity: 30 to 85% RH (non-condensing)
Grounding: grounding resistance ≤100Ω
B
x
1 kWh
x
10 kWh
Mounting: panel flush mounting
Dimensions: W110×H110×D126 mm (4.33"×4.33"×4.96")
DISPLAY
DISPLAY
Weight:
500 g (1.10 lbs)
S.R.
A
V RESET
PERFORMANCE in percentage of span
Accuracy
Voltage, current: ±1.0%
Watt, var: ±1.5%
Power factor: ±3.0%
Frequency: ±0.5%
Demand: ±1.5%
Zero-phase voltage: ±1.5%
E
F
G H
J
A. Display
LED:
Display items:
10 mm (.39") 7 segment, orange
NO. OF
DIGITS
DISPLAY ITEMS
REMARKS
Current
Voltage
Watt
A (1, N, 2)
A (R, S, T)
4
4
Single-phase / 3-wire
3-phase / 3-wire or 4-wire
Max. zero-phase voltage: ±1.5%
Watthours: ±2.0% (load current 5 – 100%, power factor 1.0)
±2.5% (load current 10 – 100%, power
factor 0.5, lag current)
V (RS, ST, TR)
4
4
3-phase / 3-wire or 4-wire
3-phase / 4-wire
V
(RN, SN, TN)
kW
4
– indicator (reverse flow),
×1, ×10 scaling factor ind. LED
×1, ×10, ×100 scaling factor LED
Varhours: ±2.5% (load current 10 – 100%, power factor 0)
±2.5% (load current 20 – 100%, power factor 0.866)
±3.0% (load current 10%, power factor 0.866)
Temp. conditioning incl. in the accuray: 23 ±10°C
(73.4 ±18°F)
Watthours kWh
5
4
Var
kvar
– indicator (lead),
×1, ×10 scaling factor ind. LED
×1, ×10, ×100 scaling factor LED
– indicator (lead)
Varhours
Power factor
Frequency
kvarh
5
3
3
Freq. conditioning incl. in the accuracy: 45 – 65 Hz
Response time: ≤2 sec. (0 – 100% ±1%)
PF
Hz
Ripple:
0.5% p-p max.
Zero-phase voltage V0
Max. zero-phase volt. MV0
4
4
4
Auxiliary supply voltage effect: ±0.1% over voltage
range
Demand
DA
Measuring/displaying
preset element only
Power failure protection: VT/CT scaling factors,
watthours, max. zero-phase voltage and
demand are stored in non-volatile memory.
Insulation resistance: ≥100MΩ with 500V DC
Dielectric strength: 2000V AC @1 minute
(voltage input to current input to trans-
mission section to display switch input to
aux. power to ground terminal)
Max. demand
MDA
4
When values exceed the preset values, corresponding LEDs blink.
B. Multiplication factor: watt, watthours, var or
varhours on the display (A)
C. Line current indicators: Pressing DISPLAY (J) or
"A" (F) button changes lines (elements).
D. Line current indicators: Pressing DISPLAY (J) or
"V" (G) button changes lines.
2000V AC @1 minute
(circuit to ground terminal; not applica-
ble to analog or transmission terminal)
Surge withstand voltage: 1.2/50 µsec., ±4.5kV
(input to output or ground; not applica-
ble to analog or transmission terminal)
E. Primary rating: indicating the primary rating of
current, voltage, watt or demand
F. Line current switch
G. Line voltage switch
H. Reset: resetting the max. zero-phase voltage or
max. demand; same as the external reset
input via output terminals
J. Display: changing display items, turning the light
on or off; same as the Dis. input via
output terminals
P. 3 / 16 ES-6481 Rev.9
51U
EXTERNAL DIMENSIONS mm (inch)
❑SINGLE-PHASE / 2-WIRE or 3-WIRE, 3-PHASE / 3-WIRE CONNECTION
35 (1.38)
110 ±1 (4.33 ±.04)
73 ±1 (2.87 ±.04)
19
M4 SCREW
18
(.71)
(.75)
8(.31)
8(.31)
6(.24)
M5 SCREW
M3 SCREW
❑3-PHASE / 4-WIRE CONNECTION
35 (1.38)
110 ±1 (4.33 ±.04)
73 ±1 (2.87 ±.04)
19
M4 SCREW
18
(.71)
(.75)
8(.31)
8(.31)
6(.24)
16
(.63)
M5 SCREW
M3 SCREW
MOUNTING REQUIREMENTS mm (inch)
❑PANEL CUTOUT
90 ±0.5
(3.54 ±0.2)
102
+1
0 dia.
2– 6 (.24) dia.
160 (6.30) min.
Panel Thickness: 1 to 5.5 mm (.04 – .22 in.)
Specifications subject to change without notice.
P. 4 / 16 ES-6481 Rev.9
MODEL
SINGLE-PHASE / 2-WIRE CONNECTION
51U-0
MODEL & SUFFIX CODE SELECTION
CONNECTION DIAGRAM
51U–0❑❑–❑❑
MODEL
P
N
E
INPUT (balanced)
0 : Single-phase / 2-wire, 105V / 5A AC
DISPLAY ITEMS
Power
V1 V2 V3 1S 1L 3S 3L
Input
C : A, V
Output
D : A, V, kW
E : A, V, kWh
CH1
CH2
CH3
Dis
F : A, kW, kWh
J : A, DA, MDA
K : A or DA, MDA, alarm setpoint
N : V, kW, kWh
❑ POWER
DC or AC
POWER
P : A or DA or MDA, V, kWh
U : V, Hz
W : A or DA or MDA, V, alarm setpoint
P
N
E
V = Line voltage
kW = Kilowatt
Hz = Frequency
A = Line current
kWh = Kilowatthours
❑ INPUT
CT
K
L
1
k
l
2
DA = Demand (current)
MDA = Maximum demand (current)
OUTPUT (selectable display items codes)
0 : None (J K W with reset input)
1 : 4 – 20mA DC, 3 points (C D U)
2 : 4 – 20mA DC, 2 points + pulse (E F N P)
3 : 4 – 20mA DC, 2 points + reset input (J)
4 : RS-485 (all codes selectable except K W)
AUXILIARY POWER SUPPLY
M : 85 – 264V AC
1S
V1
1L
V2
Suffix Codes
C, D, E, F, N, P, W
V1
V1
V2
V2
1S
1S
1L
1L
J, K (measuring current only)
U (measuring voltage only)
❑ OUTPUT
R : 24V DC
P : 110V DC
REMOTE CONTROL
•Without Outputs
•4 – 20mA DC, 3 points
(See the following pages.)
Dis.
•4 – 20mA DC, 2 points
+ pulse 1 point
(See the following pages.)
1 : 85 – 132V AC or 85 – 143V DC
2 : 20 – 30V DC
3 : 170 – 264V AC
POWER
POWER
DISPLAY
•RS-485
SIWTCHING
•4 – 20mA DC, 2 points
+ reset input
(See the following pages.)
Dis.
ORDERING INFORMATION
Specify code number. (e.g. 51U-0D4-M1)
+
–
SL
Ter
TERMINATOR
DISPLAY
SWITCHING
Close across the terminator
when the unit is located at
the end of transmission line.
RS-485
P. 5 / 16 ES-6481 Rev.9
51U
DISPLAY ITEMS & OUTPUTS
Items shown in brackets can be displayed when you change settings.
Suffix Code: C
Suffix Code: D
Suffix Code: E
Suffix Code: F
A
V
A
V
A
V
A
x1 kW
x10 kW
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x1 kW
x
x
x10 kW
x
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
CH1
CH2
ITEMS
TERM.
CH1
CH2
CH3 0 – 0.5 kW
(-0.5 – +0.5 kW)
ITEMS
TERM.
CH1
CH2
ITEMS
TERM.
ITEMS
A
V
A
V
A
V
CH1
A
CH2 0 – 0.5 kW
(-0.5 – +0.5 kW)
PULSE kWh
Dis. Display switch. inp.
PULSE kWh
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: J
Suffix Code: K
Suffix Code: N
Suffix Code: P
A
DA
A
DA
MDA
A
V
DA
MAX
x1 kW
A
A
V
x10 kW
MDA
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
ALARM
SET
x
x
A
A
x
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
RESET
Dis.
ALARM RESET
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
ITEMS
TERM.
ITEMS
TERM.
CH1
CH2
CH1/CH2 (DA, MDA)
PULSE kWh
ITEMS
CH1
CH2 DA (MDA)
RESET MDA ext. reset inp.
Dis. Display switch. inp.
A
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
CH1
V
A
V
CH2 0 – 0.5 kW
(-0.5 – +0.5 kW)
CH1/CH2 (A)
PULSE kWh
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: U
Suffix Code: W
V
A
Hz
V
ALARM
SET
A
DISPLAY
DISPLAY
•Output Connection
•Output Connection
+
–
+
–
CH1
CH2
Dis.
ALARM RESET
Dis.
TERM.
ITEMS
TERM.
ITEMS
CH1
V
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
CH2 Hz
Dis. Display switch. inp.
Specifications subject to change without notice.
P. 6 / 16 ES-6481 Rev.9
MODEL
SINGLE-PHASE / 3-WIRE CONNECTION
51U-1
MODEL & SUFFIX CODE SELECTION
CONNECTION DIAGRAM
51U–1❑❑–❑❑
MODEL
P
N
E
INPUT (balanced)
Power
1 : Single-phase / 3-wire, 105V / 210V / 5AAC
DISPLAY ITEMS
V1 V2 V3 1S 1L 3S 3L
Input
A : A × 3
Output
B : V × 3
C : A × 3, V × 3
CH1
CH2
CH3
Dis
D : A × 3, V × 3, kW
E : A × 3, V × 3, kWh
F : A × 3, kW, kWh
J : A × 3, DA, MDA
K : A × 3 or DA, MDA, alarm setpoint
L : Hz, PF, kW
❑ POWER
DC or AC
POWER
P
N
E
M : PF, kW, kWh
N : V × 3, kW, kWh
P : A × 3 or DA or MDA, V × 3, kWh
Q : A × 3, PF, kW
S : A × 3 or PF, kW, kWh
U : V × 3, Hz
❑ INPUT
CT
K
L
1
k
l
N
2
K
L
k
l
W : A × 3 or DA or MDA, V × 3, alarm setpoint
Y : Hz, PF, kWh
1S
V1
1L
VN
2S
V2
2L
V = Line voltage
kW = Kilowatt
PF = Power factor
DA = Demand (current)
A = Line current
kWh = Kilowatthours
Hz = Frequency
Suffix Codes
C, D, E, F, L, M, N, P, Q, S, W, Y V1 VN V2
A, J, K (measuring current only)
1S
1S
1L
1L
2S
2S
2L
2L
MDA = Maximum demand (current)
B, U (measuring voltage only)
V1 VN V2
OUTPUT (selectable display items codes)
0 : None (J K W with reset input)
1 : 4 – 20mA DC, 3 points (A B C D L Q U)
2 : 4 – 20mA DC, 2 points + pulse (E F M N P)
3 : 4 – 20mA DC, 2 points + reset input (J)
4 : RS-485 (all codes selectable except K W)
AUXILIARY POWER SUPPLY
M : 85 – 264V AC
R : 24V DC
P : 110V DC
REMOTE CONTROL
1 : 85 – 132V AC or 85 – 143V DC
2 : 20 – 30V DC
❑ OUTPUT
•Without Outputs
•4 – 20mA DC, 3 points
(See the following pages.)
Dis.
•4 – 20mA DC, 2 points
+ pulse 1 point
(See the following pages.)
POWER
POWER
DISPLAY
SIWTCHING
•RS-485
•4 – 20mA DC, 2 points
+ reset input
(See the following pages.)
Dis.
+
–
SL
Ter
TERMINATOR
DISPLAY
SWITCHING
Close across the terminator
when the unit is located at
the end of transmission line.
RS-485
3 : 170 – 264V AC
ORDERING INFORMATION
Specify code number. (e.g. 51U-1D4-M1)
P. 7 / 16 ES-6481 Rev.9
51U
DISPLAY ITEMS & OUTPUTS
Items shown in brackets can be displayed when you change settings.
Suffix Code: A
Suffix Code: B
Suffix Code: C
Suffix Code: D
1
N
2
1 – N
2 – N
1 – 2
1
N
2
1
N
2
A
A
A
V
V
V
A
V
A
V
1 – N
2 – N
1 – 2
1 – N
2 – N
1 – 2
x1 kW
x10 kW
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
Dis.
CH1
CH2
CH3
Dis.
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
ITEMS
, A
1N (V2N, V12
TERM.
CH1
CH2
CH3 0 – 1 kW
(-1 – +1 kW)
ITEMS
, A
1N (V2N, V12)
A
A
A
1
V
V
V
1N
2N
12
A
V
1
(A
N
2)
A
V
1
(A
N
2)
N
2
)
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: E
Suffix Code: F
Suffix Code: J
Suffix Code: K
1
1
1
1
N
N
N
N
2
DA
A
A
A
A
2
2
2
1 – N
2 – N
DA 1
N
x1 kW
MAX
V
A
A
1 – 2
x10 kW
2
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
MDA
ALARM
SET
x
x
A
A
x
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
RESET
Dis.
ALARM RESET
Dis.
TERM.
CH1
CH2
ITEMS
, A
1N (V2N, V12
TERM.
ITEMS
, A
TERM.
ITEMS
TERM.
ITEMS
A
V
1
(A
N
2)
CH1
A1
(A
N
2
)
CH1
CH2 DA (MDA)
RESET MDA ext. reset inp.
Dis. Display switch. inp.
A1
(A
N, A
2)
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
)
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
PULSE kWh
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: L
Suffix Code: M
Suffix Code: N
Suffix Code: P
1 – N
2 – N
1
N
2
A
DA
MDA
Hz
%
%
V
1 – 2
1 – N
2 – N
1 – 2
x1 kW
x1 kW
V
x10 kW
x10 kW
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x1 kW
x
x
x
x10 kW
x
x
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
CH1 PF
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
Dis. Display switch. inp.
ITEMS
TERM.
ITEMS
TERM.
CH1
CH2
ITEMS
, A
1N (V2N, V12)
CH1 Hz
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
Dis. Display switch. inp.
CH1
V
1N (V2N, V12
)
A
V
1
(A
N
2)
CH2 0 – 1 kW
(-1 – +1 kW)
, A , A
PULSE kWh
Dis. Display switch. inp.
CH1/CH2 (DA, MDA)
PULSE kWh
Dis. Display switch. inp.
CH1/CH2 (A
1
N
2)
Specifications subject to change without notice.
P. 8 / 16 ES-6481 Rev.9
Suffix Code: Q
Suffix Code: S
Suffix Code: U
Suffix Code: W
1
N
2
1
N
2
A
1 – N
2 – N
1 – 2
1
N
2
A
%
DA
MDA
A
V
1 – N
2 – N
1 – 2
x1 kW
x10 kW
%
Hz
V
x
1
kWh
10 kWh
100 kWh
ALARM
SET
x1 kW
x
A
x10 kW
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
Dis.
ALARM RESET
Dis.
TERM.
ITEMS
, A
TERM.
ITEMS
, A
TERM.
ITEMS
TERM.
ITEMS
CH1
A1
(AN
2
)
CH1
A1
(AN
2
)
CH1
V
1N (V2N, V12
)
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
CH2 0 – 1 kW
(-1 – +1 kW)
CH1/CH2 (PF)
CH2 Hz
Dis. Display switch. inp.
Dis. Display switch. inp.
PULSE kWh
Dis. Display switch. inp.
Suffix Code: Y
Hz
%
x
1
kWh
10 kWh
100 kWh
x
x
DISPLAY
•Output Connection
+
–
+
–
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
CH1 Hz
CH2 PF
PULSE kWh
Dis. Display switch. inp.
P. 9 / 16 ES-6481 Rev.9
51U
MODEL
THREE-PHASE / 3-WIRE CONNECTION
51U-2 / 51U-3
MODEL & SUFFIX CODE SELECTION
ORDERING INFORMATION
Specify code number. (e.g. 51U-2D4-M1)
51U–❑❑❑–❑❑
MODEL
CONNECTION DIAGRAM
INPUT (balanced)
2 : Three-phase / 3-wire, 220V / 5A AC
3 : Three-phase / 3-wire, 110V / 5A AC
DISPLAY ITEMS
P
N
E
Power
A : A × 3
B : V × 3
V1 V2 V3 1S 1L 3S 3L
Input
C : A × 3, V × 3
Output
D : A × 3, V × 3, kW
E : A × 3, V × 3, kWh
F : A × 3, kW, kWh
G : Hz, PF, kvar
CH1
CH2
CH3
Dis
H : V × 3, MV
J : A × 3, DA, MDA
0
, V
0
❑ POWER
DC or AC
POWER
K : A × 3 or DA, MDA, alarm setpoint
L : Hz, PF, kW
M : PF, kW, kWh
P
N
E
N : V × 3, kW, kWh
❑ INPUT
P : A × 3 or DA or MDA, V × 3, kWh
Q : A × 3, PF, kW
R : A × 3, PF, kvar
S : A × 3 or PF, kW, kWh
T : A × 3, PF, kvarh
CT
K
L
R
S
T
R
S
T
k
l
K
L
k
l
U
u
V V
U
u
U
u
V
v
W
O
O
VT
GVT
v v
w
a
f
1S
U : V × 3, Hz
V1
1L
V1
V2
3S
V2
V3
3L
V3
W : A × 3 or DA or MDA, V × 3, alarm setpoint
X : A × 3, kvar, kvarh
Y : Hz, PF, kWh
Suffix Codes
V1 V2 V3 1S 1L 3S 3L
C, D, E, F, G, L, M, N, P, Q, R, S, T, W, X, Y
V = Line voltage
kW = Kilowatt
PF = Power factor
A = Line current
kvar = Kilovar
Hz = Frequency
V1 V2 V3 G1 G4
H (measuring max. zero-phase voltage)
1S 1L 3S 3L
220V AC can be directly connected
to V1, V2 and V3 terminals without
VT.
kWh = Kilowatthours kvarh = Kilovarhours
DA = Demand (current)
MDA = Maximum demand (current)
V0 = Zero-phase voltage
A, J, K (measuring current only)
V1 V2 V3
B, U (measuring voltage only)
❑ OUTPUT
MV0 = Maximum zero-phase voltage
•Without Outputs
•4 – 20mA DC, 3 points
(See the following pages.)
Dis.
OUTPUT (selectable display items codes)
0 : None (H J K W with reset input)
1 : 4 – 20mA DC, 3 points (A B C D G L Q R U)
2 : 4 – 20mA DC, 2 points + pulse
(E F M N P S T X Y)
3 : 4 – 20mA DC, 2 points + reset input (H J)
4 : RS-485 (all codes selectable except K W)
AUXILIARY POWER SUPPLY
M : 85 – 264V AC
•4 – 20mA DC, 2 points
+ pulse 1 point
(See the following pages.)
POWER
DISPLAY
SIWTCHING
•RS-485
•4 – 20mA DC, 2 points
+ reset input
(See the following pages.)
Dis.
+
–
SL
Ter
POWER
Close across the terminator
when the unit is located at
the end of transmission line.
TERMINATOR
DISPLAY
SWITCHING
RS-485
R : 24V DC
P : 110V DC
REMOTE CONTROL
1 : 85 – 132V AC or 85 – 143V DC
2 : 20 – 30V DC
3 : 170 – 264V AC
Specifications subject to change without notice.
P. 10 / 16 ES-6481 Rev.9
DISPLAY ITEMS & OUTPUTS
Items shown in brackets can be displayed when you change settings.
Suffix Code: A
Suffix Code: B
Suffix Code: C
Suffix Code: D
R
S
T
R – S
S – T
T – R
R
S
T
R
S
T
A
A
A
V
V
V
A
V
A
V
R – S
S – T
T – R
R – S
S – T
T – R
x1 kW
x10 kW
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
Dis.
CH1
CH2
CH3
Dis.
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
ITEMS
, A
RS (VST, VTR
TERM.
CH1
CH2
CH3 0 – 1 kW
(-1 – +1 kW)
ITEMS
, A
RS (VST, VTR)
A
A
A
R
S
T
V
V
V
RS
ST
TR
A
V
R
(A
S
T
)
A
V
R
(A
S
T)
)
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: E
Suffix Code: F
Suffix Code: G
Suffix Code: H
R
S
R
S
R – S
S – T
A
A
Hz
%
V
T
T
T – R
R – S
S – T
MV0
x1 kW
V
V
T – R
x10 kW
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
V0
x
x
x1 kvar
V
x
x
x10 kvar
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
RESET
Dis.
TERM.
CH1
CH2
ITEMS
, A
RS (VST, VTR
TERM.
ITEMS
, A
TERM.
ITEMS
TERM.
ITEMS
A
V
R
(A
S
T
)
CH1
AR
(A
S
T
)
CH1 Hz
CH2 PF
CH3 0 – lag1 kvar
CH1
CH2 MV
RESET MV
Dis. Display switch. inp.
VRS (VST, VTR)
)
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
0
PULSE kWh
Dis. Display switch. inp.
0
ext. reset inp.
(lead1 – lag1 kvar)
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: J
Suffix Code: K
Suffix Code: L
Suffix Code: M
R
S
R
S
T
DA
A
A
Hz
%
%
T
DAR
S
MAX
x1 kW
A
A
T
x10 kW
MDA
x
1
kWh
10 kWh
100 kWh
ALARM
SET
x1 kW
x
A
A
x10 kW
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
RESET
Dis.
ALARM RESET
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
ITEMS
TERM.
ITEMS
TERM.
CH1 PF
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
ITEMS
CH1
CH2 DA (MDA)
RESET MDA ext. reset inp.
Dis. Display switch. inp.
AR
(A
S
, A
T
)
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
CH1 Hz
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
Dis. Display switch. inp.
Dis. Display switch. inp.
P. 11 / 16 ES-6481 Rev.9
51U
Suffix Code: N
Suffix Code: P
Suffix Code: Q
Suffix Code: R
R – S
S – T
T – R
R
S
T
A
R
S
T
R
S
T
DA
MDA
V
A
A
R – S
S – T
T – R
x1 kW
x10 kW
V
%
%
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x
x
x1 kW
x1 kvar
x
x
x10 kW
x10 kvar
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
CH3
Dis.
TERM.
ITEMS
TERM.
CH1
ITEMS
, A
TERM.
ITEMS
, A
TERM.
ITEMS
, A
CH1
V
RS (VST, VTR
)
AR
(AS
T
)
CH1
AR
(AS
T
)
CH1
AR
(AS
T)
CH2 0 – 1 kW
(-1 – +1 kW)
, A , A
PULSE kWh
CH2
V
RS (VST, VTR
)
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
CH2 PF
CH3 0 – lag1 kvar
(lead1 – lag1 kvar)
Dis. Display switch. inp.
CH1/CH2 (DA, MDA)
PULSE kWh
Dis. Display switch. inp.
CH1/CH2 (A
R
S
T
)
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: S
Suffix Code: T
Suffix Code: U
Suffix Code: W
R
S
T
A
R
S
R – S
S – T
R
S
%
A
V
A
T
T – R
T
R – S
S – T
x1 kW
x10 kW
%
Hz
V
T – R
x
1
kWh
10 kWh
100 kWh
x1kvarh
x10kvarh
x100kvarh
ALARM
SET
x
A
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
Dis.
ALARM RESET
Dis.
TERM.
ITEMS
, A
TERM.
ITEMS
TERM.
ITEMS
TERM.
ITEMS
CH1
AR
(AS
T
)
CH1
CH2 PF
PULSE kvarh
AR
(A
S
, AT
)
CH1
CH2 Hz
Dis. Display switch. inp.
V
RS (VST, VTR
)
ALARM DA alarm output
RESET MDA ext. reset inp.
Dis. Display switch. inp.
CH2 0 – 1 kW
(-1 – +1 kW)
CH1/CH2 (PF)
Dis. Display switch. inp.
PULSE kWh
Dis. Display switch. inp.
Suffix Code: X
Suffix Code: Y
R
S
A
Hz
%
T
x1 kvar
x10 kvar
x1 kvarh
x10 kvarh
x100 kvarh
x
1
kWh
10 kWh
100 kWh
x
x
DISPLAY
DISPLAY
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
ITEMS
CH1
A
R
(A
S
, A
T
)
CH1 Hz
CH2 PF
PULSE kWh
Dis. Display switch. inp.
CH2 0 – lag1 kvar
(lead1 – lag1 kvar)
PULSE kvarh
Dis. Display switch. inp.
Specifications subject to change without notice.
P. 12 / 16 ES-6481 Rev.9
MODEL
THREE-PHASE / 4-WIRE CONNECTION
51U-4
MODEL & SUFFIX CODE SELECTION
CONNECTION DIAGRAM
51U–4❑❑–❑❑
MODEL
P
N
E
V1 V2 V3 VN
INPUT (balanced)
4 : 3-phase / 4-wire, 110V / √ 3 V / 5A AC
DISPLAY ITEMS
Power
Input
1S 1L 2S 2L 3S 3L
Input
A : A × 3
B : V × 3
Output
CH1
CH2
CH3
Dis
CT
C : A × 3, V × 3
D : A × 3, V × 3, kW
E : A × 3, V × 3, kWh
F : A × 3, kW, kWh
G : Hz, PF, kvar
J : A × 3, DA, MDA
L : Hz, PF, kW
❑ POWER & INPUT
K
L
R
S
T
k
l
K
L
k
l
K
L
k
l
N
V
U
V
1S
M : PF, kW, kWh
U
U
V
v
1L
VT
2S
N : V × 3, kW, kWh
P : A × 3 or DA or MDA, V × 3, kWh
Q : A × 3, PF, kW
R : A × 3, PF, kvar
S : A × 3 or PF, kW, kWh
T : A × 3, PF, kvarh
U : V × 3, Hz
u
v u v u
2L
3S
V1
3L
V2
DC or AC
POWER
V3
VN
Suffix Codes
P
N
E
V1
V2
V3 VN
C, D, E, F, G, L, M, N, P, Q, R, S, T, X, Y
X : A × 3, kvar, kvarh
Y : Hz, PF, kWh
P
N
E
A, J (measuring current only)
V = Line voltage
kW = Kilowatt
PF = Power factor
A = Line current
kvar = Kilovar
Hz = Frequency
P
N
E
V1 V2
V3 VN
B, U (measuring voltage only)
kWh = Kilowatthours kvarh = Kilovarhours
DA = Demand (current)
MDA = Maximum demand (current)
V0 = Zero-phase voltage
MV0 = Maximum zero-phase voltage
Suffix Codes
1S
C, D, E, F, G, L, M, N, P, Q, R, S, T, X, Y
1S 1L 2S 2L 3S 3L
1L
2S
2L
3S
3L
OUTPUT (selectable display items codes)
0 : None (J with reset input)
1 : 4 – 20mA DC, 3 points (A B C D G L Q R U)
2 : 4 – 20mA DC, 2 points + pulse
(E F M N P S T X Y)
A, J (measuring current only)
B, U (measuring voltage only)
❑ OUTPUT
•Without Outputs
•4 – 20mA DC, 3 points
(See the following pages.)
3 : 4 – 20mA DC, 2 points + reset input (J)
4 : RS-485
Dis.
•4 – 20mA DC, 2 points
+ pulse 1 point
(See the following pages.)
AUXILIARY POWER SUPPLY
M : 85 – 264V AC
R : 24V DC
POWER
DISPLAY
•RS-485
SIWTCHING
•4 – 20mA DC, 2 points
+ reset input
(See the following pages.)
P : 110V DC
Dis.
REMOTE CONTROL
1 : 85 – 132V AC or 85 – 143V DC
2 : 20 – 30V DC
3 : 170 – 264V AC
+
–
SL
Ter
POWER
Close across the terminator
when the unit is located at
the end of transmission line.
TERMINATOR
DISPLAY
SWITCHING
RS-485
ORDERING INFORMATION
Specify code number. (e.g. 51U-4D4-M1)
P. 13 / 16 ES-6481 Rev.9
51U
DISPLAY ITEMS & OUTPUTS
Items shown in brackets can be displayed when you change settings.
Suffix Code: A
Suffix Code: B
Suffix Code: C
Suffix Code: D
R
S
T
R – N(S)
S – N(T)
T – N(R)
PHASE
LINE
R
S
T
R
S
T
A
A
A
A
PHASE
A
PHASE
V
PHASE
LINE
R
S
T
–
–
–
N(S)
N(T)
N(R)
R
S
T
–
–
–
N(S)
N(T)
N(R)
LINE
LINE
V
V
V
PHASE
LINE
x1 kW
x10 kW
V
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
Dis.
CH1
CH2
CH3
Dis.
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
CH3
ITEMS
TERM.
CH1
CH2
ITEMS
, A
RS (VST, VTR
TERM.
CH1
CH2
CH3 0 – 1 kW
(-1 – +1 kW)
ITEMS
, A
RS (VST, VTR)
A
A
A
R
S
T
V
V
V
RS
ST
TR
A
V
R
(A
S
T
)
A
V
R
(A
S
T)
)
CH1/CH2 (VRN, VSN, VTN
Dis. Display switch. inp.
)
Dis. Display switch. inp.
CH1/2/3 (VRN, VSN, VTN
)
Dis. Display switch. inp.
CH1/2/3 (VRN, VSN, VTN)
Dis. Display switch. inp.
Suffix Code: E
Suffix Code: F
Suffix Code: G
Suffix Code: J
R
S
R
S
R
S
A
PHASE
A
Hz
%
A
T
T
T
R
S
T
–
–
–
N(S)
N(T)
N(R)
DAR
S
LINE
x1 kW
A
x10 kW
T
V
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
MDA
x
x
x1 kvar
A
x
x
x10 kvar
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
RESET
Dis.
TERM.
CH1
CH2
CH1/CH2 (VRN, VSN, VTN
PULSE kWh
ITEMS
, A
RS (VST, VTR
TERM.
ITEMS
, A
TERM.
ITEMS
TERM.
ITEMS
A
V
R
(A
S
T
)
CH1
AR
(A
S
T
)
CH1 Hz
CH2 PF
CH3 0 – lag1 kvar
CH1
CH2 DA (MDA)
RESET MDA ext. reset inp.
Dis. Display switch. inp.
AR
(A
S, AT)
)
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
)
(lead1 – lag1 kvar)
Dis. Display switch. inp.
Dis. Display switch. inp.
Dis. Display switch. inp.
Suffix Code: L
Suffix Code: M
Suffix Code: N
Suffix Code: P
R
S
T
–
–
–
N(S)
N(T)
N(R)
PHASE
LINE
R
S
T
A
DA
MDA
Hz
%
%
V
R
S
T
–
–
–
N(S)
N(T)
N(R)
PHASE
LINE
x1 kW
x1 kW
x10 kW
x10 kW
V
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x
1
kWh
10 kWh
100 kWh
x1 kW
x
x
x
x10 kW
x
x
x
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
CH1 PF
CH2 0 – 1 kW
(-1 – +1 kW)
PULSE kWh
Dis. Display switch. inp.
ITEMS
TERM.
ITEMS
TERM.
CH1
CH2
CH1/CH2 (VRN, VSN, VTN
(DA, MDA)
PULSE kWh
ITEMS
, A
RS (VST, VTR)
CH1 Hz
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
Dis. Display switch. inp.
CH1
V
RS (VST, VTR
)
A
V
R
(A
S
T)
CH2 0 – 1 kW
(-1 – +1 kW)
)
CH1/CH2 (AR, AS, AT) (VRN, VSN, VTN)
PULSE kWh
Dis. Display switch. inp.
Dis. Display switch. inp.
Specifications subject to change without notice.
P. 14 / 16 ES-6481 Rev.9
Suffix Code: Q
Suffix Code: R
Suffix Code: S
Suffix Code: T
R
S
T
R
S
T
R
S
T
A
R
S
T
%
A
A
A
x1 kW
x10 kW
%
%
%
x
1
kWh
10 kWh
100 kWh
x1kvarh
x1 kW
x1 kvar
x
x10kvarh
x10 kW
x10 kvar
x
x100kvarh
DISPLAY
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
CH3
Dis.
CH1
CH2
CH3
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
, A
TERM.
ITEMS
, A
TERM.
ITEMS
, A
TERM.
ITEMS
, A
CH1
AR
(AS
T
)
CH1
AR
(AS
T
)
CH1
AR
(AS
T
)
CH1
AR
(AS
T)
CH2 PF
CH3 0 – 1 kW
(-1 – +1 kW)
CH2 PF
CH3 0 – lag1 kvar
CH2 0 – 1 kW
(-1 – +1 kW)
CH1/CH2 (PF)
CH2 PF
PULSE kvarh
Dis. Display switch. inp.
(lead1 – lag1 kvar)
Dis. Display switch. inp.
Dis. Display switch. inp.
PULSE kWh
Dis. Display switch. inp.
Suffix Code: Y
Suffix Code: U
Suffix Code: X
R
S
T
–
–
–
N(S)
N(T)
N(R)
PHASE
LINE
R
S
Hz
%
A
T
V
x1 kvar
Hz
x10 kvar
x
1
kWh
10 kWh
100 kWh
x1 kvarh
x10 kvarh
x100 kvarh
x
x
DISPLAY
DISPLAY
DISPLAY
•Output Connection
•Output Connection
•Output Connection
+
–
+
–
+
–
+
–
+
–
+
–
CH1
CH2
Dis.
CH1
CH2
PULSE
Dis.
CH1
CH2
PULSE
Dis.
TERM.
ITEMS
TERM.
ITEMS
TERM.
ITEMS
CH1 Hz
CH2 PF
PULSE kWh
Dis. Display switch. inp.
CH1
CH2 Hz
CH1/CH2 (VRN, VSN, VTN
Dis. Display switch. inp.
V
RS (VST, VTR
)
CH1
A
R
(A
S, AT)
CH2 0 – lag1 kvar
(lead1 – lag1 kvar)
PULSE kvarh
Dis. Display switch. inp.
)
P. 15 / 16 ES-6481 Rev.9
51U
SYSTEM CONFIGURATION EXAMPLE
Nest Bus
32 Units Max.
32 Points Max.
Communication Interface
for 51-UNIT Use
model: SMDU
RS-485 (Multi-Meter Protocol, 31 units per kilometer)*
Multi Power Meter
model: 51U
R
S
T
R
S
T
R
S
T
A
V
A
V
A
V
R-
R-
R-
S
S-
T
S
S
S-
S-
T
T
T-
T-
T-
R
R
R
x1
P
x1
P
x1
P
kW
kW
kW
x1
x1
x1
0k
0k
0k
W
W
W
D
D
D
IS
IS
IS
LA
LA
LA
Y
Y
Y
*MsysNet use only. Consult Factory.
Specifications subject to change without notice.
P. 16 / 16 ES-6481 Rev.9
51U-E0-R1 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
51U-E0-R2 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E0-R3 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-M1 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-M2 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-M3 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-P1 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-P2 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-P3 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-R1 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E1-R2 | MSYSTEM | Panel Mounted Multi Power Meter 51-UNIT | 获取价格 |
![]() |
51U-E0-R1 相关文章

- 2025-02-26
- 100


- 2025-02-26
- 107


- 2025-02-26
- 76


- 2025-02-26
- 77