2012H
更新时间:2025-01-16 07:59:29
品牌:SYSTEMSENSOR
描述:Direct-Wire Smoke Detector with Built-in Relay and Horn
2012H 概述
Direct-Wire Smoke Detector with Built-in Relay and Horn 直接线烟感探测器,带内置继电器和非洲之角
2012H 数据手册
通过下载2012H数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载2012H Direct-Wire
Smoke Detector with
Built-in Relay and Horn
Model
2012H
Photoelectronic Detector
2012H
Photoelectronic
Smoke Detector
Required Accessory
A77-727-01 12 VDC power supply
(required for system to be
UL listed)
Product Overview
12 VDC operation, 4-wire
Compact, attractive, and easy to install, the System Sensor 2012H detector is
designed to respond to a broad range of fires while providing maximum stability. This
model also features low-voltage wiring making it ideal for applications such as apart-
ment buildings and nursing homes.
Built-in 85dB electronic horn with
temporal (3) tone
Built-in, normally open relay can be
connected to lights, bells, horns,
or remote annunciator
Features. The System Sensor 2012H photoelectronic detector is designed prima-
rily for applications where low-voltage Class 2 wiring may be used. This detec-
tor is non-latching and offers an 85dB alarm horn. The 2012H features the
NFPA72 required audible emergency evacuation signal referred to as temporal
(3) tone. An external push button provides a test of the detector's alarm func-
tion. Up to 12 units can be interconnected so that if one detector alarms, all
detectors alarm. A normally open auxiliary alarm relay with an 8 second delay
is available for controlling external functions. A visible LED indicator flashes
once every 30 seconds in standby and rapidly (every 0.5 seconds) in alarm
when detecting smoke. The detector offers low-voltage operation and a tamper-
proof feature. Screw terminals and a mounting bracket are provided for easy
installation.
Interconnectable up to 12 units
Visual alarm and power indicator
Ceiling white color
Built-in 8 second delay on relay output
Built-in test switch
Twist-on mounting bracket with
tamper option for easy installation
Rugged chamber design for greater
stability
3-year warranty
General Specifications
Residential Smoke Detector Placement
Size
As defined in NFPA72 “Smoke detectors shall be installed outside of each separate
sleeping area in the immediate vicinity of the bedrooms and on each additional story
of the family living unit, including basements and excluding crawlspaces and unfin-
ished attics. In new construction, a smoke detector shall also be installed in each
sleeping room”.
1.75″ H x 5.5″ dia.
(44.5 mm h x 140 mm dia.)
Weight
5.3 oz. (150 grams)
Humidity Range
10% to 93% RH, noncondensing
Electrical Ratings
Operating Voltage
12 VDC (nominal)
Standby Current
60 µA maximum average
Temperature Range
32° to 120°F (0° to 50°C)
Relay Contact Rating
Alarm Current
1 Form A, .5 A @ 30 VDC
20 mA maximum average @ 12 VDC
2012H Wiring Diagram
Maximum power bus length (in feet), given number
of units (maximum per bus) and wire size.
A77-727-O1
RED
(+)
BLACK
Wire Gauge
1 Unit
14 AWG 16 AWG 18 AWG
12VDC POWER
SUPPLY
12OVAC
BLACK
(–)
5000
2970
1980
1485
1188
990
3735
1867
1245
933
747
622
533
466
415
373
339
311
2349
1174
783
587
469
391
335
293
261
234
213
195
GRAY
2 Units
3 Units
4 Units
5 Units
6 Units
7 Units
8 Units
9 Units
10 Units
11 Units
12 Units
(+) (–)
POWER INPUT
(+) (–)
POWER INPUT
(+) (–)
POWER INPUT
SIGNAL
GROUND
SIGNAL
SIGNAL
GROUND
GROUND
AUXILIARY
AUXILIARY
AUXILIARY
848
742
660
594
540
495
(+) (–)
POWER INPUT
(+) (–)
POWER INPUT
(+) (–)
POWER INPUT
SIGNAL
GROUND
SIGNAL
GROUND
SIGNAL
GROUND
Maximum interconnect bus length:
5,000 FT., No. 18AWG or larger dual
conductor cable.
Auxiliary
Alarm Relay
AUXILIARY
AUXILIARY
AUXILIARY
All wiring must conform to local electrical codes.
Interconnect Up To
12 Detectors
Ordering Information
Part Number
2012H
Description
Photoelectronic smoke detector with relay, 12 VDC, multiple station
1
A77-727-01
12 VDC power supply, mounts to a 4″ square box, 2 ⁄
8
″ deep
System Sensor Sales and Service
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800-SENSOR2
Fx: 630/377-6495
Documents On Demand
1-800-736-7672 x3
System Sensor Canada
Ph: 905.812.0767
Fx: 905.812.0771
System Sensor in China
Ph: 011.86.29.524.6253
Fx: 011.86.29.524.6259
System Sensor– Far East
Ph: 011.852.2191.9003
Fx: 011.852.2736.6580
System Sensor UK
Ph: 011.44.1403.276500
Fx: 011.44.1403.276501
System Sensor in Singapore
Ph: 011.65.273.2230
Fx: 011.65.273.2610
System Sensor– Australia
Ph: 011.613.54.281.142
Fx: 011.613.54.281.172
www.systemsensor.com
© 1999 System Sensor. The company reserves the right to change product specifications without notice.
A05-238-03•6/99(10K)•#475
2012H 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
2012S12 | MAKE-PS | Single, Dual, Triple Output DC/DC Converter | 获取价格 | |
2012S12WFR | MAKE-PS | Single & Dual Output DC/DC Converter | 获取价格 | |
2012S12WFR-Y | COOPER | Analog Circuit, | 获取价格 | |
2012S24 | MAKE-PS | Single, Dual, Triple Output DC/DC Converter | 获取价格 | |
2012S24WFR | MAKE-PS | Single & Dual Output DC/DC Converter | 获取价格 | |
2012S24WFR | COOPER | Analog Circuit, | 获取价格 | |
2012S24WFR-Y | COOPER | Analog Circuit, | 获取价格 | |
2012S48 | MAKE-PS | Single, Dual, Triple Output DC/DC Converter | 获取价格 | |
2012S48WFR | MAKE-PS | Single & Dual Output DC/DC Converter | 获取价格 | |
2012T100 | TAIYO YUDEN | Please read this notice before using the TAIYO YUDEN products. | 获取价格 |
2012H 相关文章
- 2025-01-17
- 11
- 2025-01-17
- 11
- 2025-01-17
- 10
- 2025-01-17
- 11