Loop-Powered
4 mA to 20 mA DAC
a
AD421
FEATURES
FUNCTIONAL BLOCK DIAGRAM
4 mA to 20 mA Current Output
HART® Compatible
REF IN
(+2.5V)
REF OUT2
(+2.5V)
REF OUT1
(+1.25V)
16-Bit Resolution and Monotonicity
؎0.01% Integral Nonlinearity
5 V or 3 V Regulator Output
2.5 V and 1.25 V Precision Reference
750 A Quiescent Current max
Programmable Alarm Current Capability
Flexible High Speed Serial Interface
16-Lead SOIC and PDIP Packages
LV
V
CC
75k⍀
112.5k⍀
AD421
134k⍀
DRIVE
COMP
BANDGAP
REFERENCE
121k⍀
BOOST
LOCAL
OSCILLATOR
DATA
INPUT SHIFT
REGISTER
CLOCK
SWITCHED
CURRENT
SOURCES
AND
16-BIT
SIGMA-
DELTA DAC
DAC LATCH
LATCH
40⍀
80k⍀
GENERAL DESCRIPTION
FILTERING
LOOP
RTN
POWER-ON
RESET
The AD421 is a complete, loop-powered, digital to 4 mA to
20 mA converter, designed to meet the needs of smart trans-
mitter manufacturers in the Industrial Control industry. It pro-
vides a high precision, fully integrated, low cost solution in a
compact 16-lead package. The AD421 is ideal for extending the
resolution of smart 4 mA to 20 mA transmitters at very low cost.
COM
C1 C2 C3
PRODUCT HIGHLIGHTS
1. The AD421 is a single chip, high performance, low cost
solution for generating 4 mA to 20 mA signals for smart
industrial control transmitters.
The AD421 includes a selectable regulator that is used to power
itself and other devices in the transmitter. This regulator pro-
vides either a +5 V, +3.3 V or +3 V regulated output voltage.
The part also contains +1.25 V and +2.5 V precision references.
The AD421 thus eliminates the need for a discrete regulator
and voltage reference. The only external components required
are a number of passive components and a pass transistor to
span large loop voltages.
2. The AD421’s regulated supply voltage can be used to power
any additional circuits in the transmitter. The regulated
output value is pin selectable as either +3 V, +3.3 V or +5 V.
3. The AD421’s on-chip references can provide a precision
reference voltage to other devices in the system. This refer-
ence voltage can be either +1.25 V or +2.5 V.
The AD421 can be used with standard HART FSK protocol
communication circuitry without any degradation in specified
performance. The high speed serial interface is capable of oper-
ating at 10 Mbps and allows for simple connection to com-
monly-used microprocessors and microcontrollers via a standard
three-wire serial interface.
4. The AD421 is fully compatible with standard HART cir-
cuitry or other similar FSK protocols.
5. With the addition of a single discrete transistor, the AD421
can be operated from VCC + 2 V min to a maximum of the
breakdown voltage of the pass transistor.
The sigma-delta architecture of the DAC guarantees 16-bit
monotonicity while the integral nonlinearity for the AD421 is
0.01%. The part provides a zero scale 4 mA output current
with 0.1% offset error and a 20 mA full-scale output current
with 0.2% gain error.
6. The AD421 converts the digital data to current with 16-bit
resolution and monotonicity. Full-scale settling time to
0.1% typically occurs within 8 ms.
7. The AD421 features a programmable alarm current capabil-
ity that allows the transmitter to send out of range currents to
indicate a transducer fault.
The AD421 is available in a 16-lead, 0.3 inch-wide, plastic DIP
and in a 16-lead, 0.3 inch-wide, SOIC package. The part is speci-
fied over the industrial temperature range of –40°C to +85°C.
HART is a registered trademark of the HART Communication
Foundation.
REV. C
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
Fax: 781/326-8703
World Wide Web Site: http://www.analog.com
© Analog Devices, Inc., 2000
(Using DN25D1 as pass transistor as per Figure 3;
REF IN = REF OUT2; T = TMIN to TMAX unless otherwise noted)
AD421–LOOP-POWERED SPECIFICATIONS
A
Parameter
B Versions2
Units
Conditions/Comments
OUTPUT CHARACTERISTICS
Current Loop Voltage Compliance3
VCC + 2
V min
350
8
25
2
V max
DN25D Breakdown Voltage
Settling Time to 0.1%, C1 = C2 = 10 nF, C3 = 3.3 nF
Full-Scale Settling Time
Output Impedance
AC Loop Voltage Sensitivity
ms typ
MΩ typ
µA/V typ
1200 Hz to 2200 Hz
VOLTAGE REGULATOR
Output Voltage (VCC
3 V Mode
3.3 V Mode
5 V Mode
Externally Available Current
Line Regulation
)
2.95/3.05
3.25/3.35
4.95/5.05
3.25
1
15
V min/V max
V min/V max
V min/V max
mA min
µV/V typ
µV/mA typ
3 V Nominal. LV Pin Connected to VCC
3.3 V Nominal. LV Pin Connected Through 0.01 µF to VCC
5 V Nominal. LV Pin Connected to COM
Assuming 4 mA Flowing in the Loop
Load Regulation
DAC SPECIFICATIONS (VCC = +3 V to +5 V; REF IN = REF OUT2; TA = TMIN to TMAX unless otherwise noted)
Parameter
B Versions2
Units
Conditions/Comments
ACCURACY
Resolution
16
Bits
Monotonicity
16
Bits min
Integral Nonlinearity
Offset (4 mA) @ +25°C4
Offset Drift
0.01
0.1
25
0.2
50
% of FS max
% of FS max
FS = Full-Scale Output Current
VCC = 5 V
ppm of FS/°C max Includes On-Chip Reference Drift
% of FS max VCC = 5 V
ppm of FS/°C max Includes On-Chip Reference Drift
nA/mV max
Total Output Error (20 mA) @ +25°C4
Total Output Drift
VCC Supply Sensitivity
50
25 nA/mV Typical
VOLTAGE REFERENCE
REF OUT2
Output Voltage
Drift
2.49/2.51
40
V min/V max
ppm/°C max
2.5 V Nominal
20 ppm/°C Typical from –40°C to +25°C and
–2.5 ppm/°C Typical from +25°C to +85°C
Externally Available Current
VCC Supply Sensitivity
Output Impedance
Noise (0.1 Hz–10 Hz)
REF OUT1
0.5
150
3
mA min
µV/V max
15 µV/V Typical
Ω typ
6
µV (p-p) typ
Output Voltage
Drift
1.24/1.26
50
V min/V max
ppm/°C max
1.25 V Nominal, 100 kΩ Load to COM5
20 ppm/°C Typical from –40°C to +25°C and
2 ppm/°C Typical from +25°C to +85°C
Externally Available Current
VCC Supply Sensitivity
Output Impedance
Noise (0.1 Hz–10 Hz)
REF IN
0.5
150
3
mA min
µV/V max
15 µV/V Typical
Ω typ
4
µV (p-p) typ
Input Resistance
40
kΩ typ
DIGITAL INPUTS
VIH (Logic 1)
VIL (Logic 0)
IIH
0.75 × VCC
0.25 × VCC
10
10
Binary
10
V min
V max
µA max
µA max
VIN = VCC
VIN = 0 V
IIL
Data Coding
Data Rate
Mbps max
POWER SUPPLIES
Operating Range
Quiescent Current
@ VCC = 3 V
+2.95 to +5.05 V min to V max
Functional to 7 V
650
750
µA max
µA max
475 µA Typical
575 µA Typical
@ VCC = 5 V
NOTES
1The DN25D is available from Supertex, Inc., 1350 Bordeaux Drive, Sunnyvale, CA 94089.
2Temperature range is –40°C to +85°C.
3The max current loop voltage compliance is determined by the pass transistor breakdown voltage and is 350 V for the DN25D.
4With VCC = 3 V, the transfer function shifts negative by typically 0.25%; a 16 kΩ resistor connected between COM and LOOPRTN will approximately compensate for the VCC
supply sensitivity in moving from 5 V to 3 V by skewing the gain of the AD421.
5100 kΩ resistor only required if this reference is being used in application circuits.
Specifications subject to change without notice.
REV. C
–2–
AD421
TIMING CHARACTERISTICS1, 2, 3
(VCC = +3 V to +5 V, TA = TMIN to TMAX unless otherwise noted)
Parameter
(B Versions)
Units
Conditions/Comments
tCK
tCL
tCH
tDW
tDS
tDH
tLD
tLL
100
50
50
30
30
0
50
50
50
ns min
ns min
ns min
ns min
ns min
ns min
ns min
ns min
ns min
Data Clock Period
Data Clock Low Time
Data Clock High Time
Data Stable Width
Data Setup Time
Data Hold Time
Latch Delay Time
Latch Low Time
Latch High Time
tLH
NOTES
1Guaranteed by characterization at initial product release, not production tested.
2See Figures 1 and 2.
3All input signals are specified with tr = tf = 5 ns (10% to 90% of VCC ) and timed from a voltage level of (VIN + VIL )/2; tr and tf should not exceed 1 µs on any digital
input.
Specifications subject to change without notice.
CLOCK
WORD "N"
WORD "N +1"
1
1
0
1
1
0
0
1
0
0
1
1
0
0
1
1
1
0
0
1
DATA
LATCH
Figure 1. Serial Interface Waveforms (Normal Data Load)
tCK
tCL
CLOCK
tCH
tDH
tDS
DATA
tDW
tLD
tLL
LATCH
tLH
Figure 2. Serial Interface Timing Diagram
–3–
REV. C
AD421
ABSOLUTE MAXIMUM RATINGS*
PIN CONFIGURATION
DIP and SOIC
(TA = +25°C unless otherwise noted)
DRIVE, BOOST, COMP to COM . . . –0.5 V to VCC + 0.5 V
LOOP RTN to COM . . . . . . . . . . . . . . . . . . . –2 V to + 0.5 V
Digital Input Voltage to COM . . . . . . . –0.5 V to VCC + 0.5 V
Operating Temperature Range
Commercial (B Version) . . . . . . . . . . . . . . –40°C to +85°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . +150°C
Plastic DIP Package, Power Dissipation . . . . . . . . . . 670 mW
1
2
3
4
5
6
7
8
16
15
REF OUT1
REF OUT2
REF IN
V
CC
BOOST
14 COMP
13
AD421
LV
LATCH
DRIVE
C1
12
TOP VIEW
(NOT TO SCALE)
CLOCK
11 C2
θ
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . 116°C/W
10
9
C3
DATA
Lead Temperature (Soldering, 10 sec) . . . . . . . . . . . . 260°C
LOOP RTN
COM
SOIC Package, Power Dissipation . . . . . . . . . . . . . . . 450 mW
θ
JA Thermal Impedance . . . . . . . . . . . . . . . . . . . . 110°C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . +215°C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . +220°C
ORDERING GUIDE
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Temperature
Range
Package
Option*
Model
AD421BN
AD421BR
AD421BRRL
EVAL-AD421EB
–40°C to +85°C
–40°C to +85°C
–40°C to +85°C
Evaluation Board
N-16
R-16
R-16; Reeled SOIC
*N = Plastic DIP, R = SOIC.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although these devices feature proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–4–
REV. C
AD421
PIN FUNCTION DESCRIPTIONS
Pin
No. Mnemonic
Function
1
REF OUT1
Reference Output 1. A precision +1.25 V reference is provided at this pin. It is intended as a precision ref-
erence source for other devices in the transmitter. REF OUT1 is a buffered output capable of providing up
to 0.5 mA to external circuitry. If REF OUT 1 is required to sink current, a resistive load of 100 kΩ to COM
should be added. (See Reference section.)
2
REF OUT2
Reference Output 2. A precision +2.5 V reference is provided at this pin. To operate the AD421 with its
own reference, REF OUT2 should be connected to REF IN. It can also be used as a precision reference
source for other devices in the transmitter. REF OUT2 is a buffered output capable of providing up to
0.5 mA to external circuitry.
3
4
REF IN
LV
Voltage Reference Input. The reference voltage for the AD421 is applied to this pin and it sets the span for
the AD421. The nominal reference voltage for the AD421 is +2.5 V for correct operation. This can be sup-
plied using an external reference source or by using the part’s own REF OUT2 voltage.
Regulated Voltage Control Input. The LV input controls the loop gain of the servo amplifier to set VCC
.
With LV connected to COM, the regulator voltage is set to 5 V nominal. If the LV input is connected through
0.01 µF to VCC, the regulated voltage is nominally 3.3 V. With LV connected to VCC the regulated voltage,
V
CC, is 3 V nominal.
5
6
LATCH
CLOCK
DAC Latch Input. Logic Input. A rising edge of the LATCH signal loads the data from the serial input shift
register to the DAC latch and hence updates the output of the DAC. The number of clock cycles provided
between latch pulses determines whether the DAC is in alarm or normal current mode. (See Digital Inter-
face section.)
Data Clock Input. Data on the DATA input is clocked into the shift register on the rising edge of this
CLOCK input. The period of this clock equals the input serial data bit rate. This serial clock rate can be up
to 10 MHz. If 16 clock cycles are provided between LATCH pulses then the data on the DATA input is
accepted as normal 4–20 mA data. If more than 16 clock cycles are provided between LATCH pulses, the
data is assumed to be alarm current data (see Digital Interface section).
7
DATA
Data Input. The data to be loaded to the AD421 input shift register is applied to this input. Data should be
valid on the rising edge of the CLOCK input.
8
9
LOOP RTN
COM
Loop Return Output. LOOP RTN is the return path for current flowing in the current loop.
Common. This is the reference potential for the AD421 analog and digital inputs and outputs and for the
voltage regulator output.
10
C3
Filtering Capacitor. A low dielectric absorption capacitor ceramic capacitor should be connected between
this pin and COM for internal filtering of the switched current sources.
11
12
13
C2
C1
DRIVE
Filtering Capacitor. See C3 description.
Filtering Capacitor. See C3 description.
Output from the Voltage Regulator Loop. The DRIVE signal controls the external pass transistor to establish and
maintain the correct VCC level programmed by the LV inputs while providing the necessary bias as the loop cur-
rent is programmed from 4 mA to 20 mA.
14
15
16
COMP
BOOST
VCC
Compensation Capacitor Input. A capacitor connected between COMP and DRIVE is required to stabilize
the feedback loop formed with the regulator op amp and the external pass transistor.
This open collector pin sinks the necessary current from the loop so that the current flowing into BOOST
plus the current flowing into COM is equal to the programmed loop current.
Power Supply. VCC is the power supply input of the AD421 and it also provides the voltage regulator output,
driven by the external pass transistor. It is used both to bias the AD421 itself and to provide power for the
rest of the smart transmitter circuitry. The LV input determines the regulated voltage output to be either
3 V, 3.3 V or 5 V nominal. Alternatively, a separate power supply can be connected to this pin to power the
AD421. VCC should be decoupled to COM with a 2.2 µF capacitor.
–5–
REV. C
AD421
CIRCUIT DESCRIPTION
Table I. FET Characteristics
N-Channel Depletion Mode
The AD421 is designed for use in loop-powered 4–20 mA smart
transmitter applications. A smart transmitter, as a remote in-
strument, controls its current output signal on the same pair of
wires from which it receives its power. The AD421 essentially
provides three primary functions in the smart transmitter. These
functions are a DAC function for converting the microprocessor/
microcontroller’s digital data to analog format, a current amp-
lifier which sets the current flowing in the loop and a voltage
regulator to provide a stable operating voltage from the loop
supply. The part also contains a high speed serial interface, two
buffered output references and a clock oscillator circuit. The
different sections of the AD421 are discussed in more detail
below.
FET Type
IDSS
24 mA min
BVDS
(VLOOP – VCC) min
VCC max
VPINCHOFF
Power Dissipation
24 mA × (VLOOP – VCC) min
where VCC is the operating voltage of the AD421 and VLOOP is
the loop voltage.
The DN25D FET transistor from Supertex1 meets all the above
requirements for the FET. Other suitable transistors include
ND2020L and ND2410L, both from Siliconix.
Voltage Regulator
There are a number of external components required to com-
pensate the regulator loop and ensure stable operation. The
capacitor from the VCC pin to the COM pin is required to
stabilize the regulator loop.
The voltage regulator consists of an op amp, bandgap reference
and an external depletion mode FET pass transistor. This cir-
cuit is required to regulate the loop voltage that powers the
AD421 itself and the rest of the transmitter circuitry. Figure 3
shows the voltage regulator section of the AD421 plus the associ-
ated external circuitry for a VCC of 3.3 V.
To provide additional compensation for the regulator loop, a
compensation capacitor of 0.01 µF should be connected
between the COMP and DRIVE pins and an external circuit
of a 1 kΩ resistor and a 1000 pF capacitor in series should be
connected between DRIVE and COM to stabilize this feed-
back loop formed with the regulator op amp and the external
pass transistor.
LOOP(+)
V
TO EXTERNAL
CIRCUITRY
CC
DN25D
2.2F
0.01F
LV
COM
V
CC
DAC Section
75k⍀
112.5k⍀
The AD421 contains a 16-bit sigma-delta DAC to convert the
digital information loaded to the input latch into a current. The
sigma-delta architecture is particularly useful for the relatively
low bandwidth requirements of the industrial control environ-
ment because of its inherent monotonicity at high resolution.
The AD421 guarantees monotonicity to the 16-bit level.
AD421
134k⍀
DRIVE
COMP
1.21V
BANDGAP
REFERENCE
0.01F
121k⍀
1k⍀
1000pF
The sigma-delta DAC consists of a second order modulator
followed by a continuous time filter. The single bit stream from
the modulator controls a switched current source. This current
source is then filtered by three resistor-capacitor filter sections.
The resistors for each of the filter sections are on-chip while
the capacitors are external on the C1–C3 pins. To meet the
specified full-scale settling on the part, low dielectric absorption
capacitors (NPO) are required. Suitable values for these capacitors
are C1 = 0.01 µF, C2 = 0.01 µF, and C3 = 0.0033 µF.
Figure 3. AD421 Voltage Regulator Circuit to Provide
VCC = 3.3 V
The signal on the LV pin selects the voltage to which VCC
regulates by changing the gain of the resistor divider between
the op amp inverting input and the VCC pin. As the LV pin
varies between COM and VCC, the voltage from the regulator
loop varies between 3 V and 5 V nominal. With LV connected
to COM, the regulated voltage is 5 V; with LV connected
through a 0.01 µF capacitor to VCC, the regulated voltage is
3.3 V while if LV is connected to VCC, the regulated voltage
is 3 V.
Current Amplifier
The DAC output current drives the second section, an opera-
tional amplifier and NPN transistor which acts as a current
amplifier to set the current flowing through the LOOP RTN
pin. Figure 4 shows the current amplifier section of the AD421.
An 80 kΩ resistor connected between the DAC output and loop
return is used as a sampling resistor to determine current. The
base drive to the NPN transistor servos the voltage across the
40 Ω resistor to equal the voltage across the 80 kΩ resistor.
The range of loop voltages that can be used by the configuration
shown in Figure 3 is determined by the FET breakdown and
saturation voltages. The external FET parameters such as Vgs
(off), IDSS and transconductance must be chosen so that the op
amp output on the DRIVE pin can control the FET operating
point while swinging in the range from VCC to COM.
The main characteristics for selecting the FET pass transistor
are as follows:
–6–
REV. C
AD421
Reference Section
SWITCHED
CURRENT
SOURCES
The AD421 contains an on-chip 1.21 V bandgap reference
which is used as part of the voltage regulator loop. A bandgap
reference is also used to generate two references voltages
which are available for use external to the AD421. Figure 5
shows the reference section of the AD421. The REF OUT1 pin
provides a buffered +1.25 V reference voltage which can supply
up to 0.5 mA of external current. The REF OUT2 pin provides
a +2.5 V reference voltage which is also capable of providing
0.5 mA of external current. To use the AD421 with its own
reference, simply connect the REF OUT2 pin to the REF IN
pin of the device. Alternatively, the part can be used with an
external reference by connecting the external reference between
REF IN and COM.
AD421
BOOST
80k⍀
40⍀
LOOP RTN
Figure 4. Current Amplifier
The BOOST pin is normally tied to the VCC pin. As the DAC
input code varies from all zeros to full scale, the output current
from the NPN transistor and thus the total loop current varies
from 4 mA to 20 mA. With BOOST and VCC tied together, the
external FET (DN25D) has to supply the full range of loop
current (4 mA to 20 mA).
When REF OUT1 and REF OUT2 are used in application
circuits, external 4.7 µF capacitors are required on the reference
pins to provide compensation and ensure stable operation of the
references. These capacitors can be omitted if the internal refer-
ences are not required.
Digital Interface
The digital interface on the AD421 consists of just three wires:
DATA, CLOCK and LATCH. The interface connects directly
to the serial ports of commonly-used microcontrollers without
the need for any external glue logic. Data is loaded MSB first
into an input shift register on the rising edge of the CLOCK
signal and is transferred to the DAC latch on the rising edge of
the LATCH signal. The timing diagrams for the serial interface
are shown in Figure 1 and Figure 2.
4.7F
4.7F
REF OUT1
(1.25V)
REF OUT2
(2.5V)
V
LV
CC
75k⍀
AD421
112.5k⍀
50k⍀
50k⍀
134k⍀
The data to be loaded to the AD421’s input shift register takes
two forms; normal 4 mA to 20 mA data or alarm current data.
The first form is where the AD421 operates over its normal
4 mA to 20 mA output range with 16 bits of resolution between
these endpoints. The second form allows the user to program a
current value outside this range as an indication from the trans-
mitter than there is a problem with the transducer. The AD421
counts the number of clock pulses which it receives between
LATCH signals as a means of determining whether the data
clocked in is 4 mA to 20 mA data or alarm current data.
2.5V
1.21V
DRIVE
BANDGAP
REFERENCE
121k⍀
Figure 5. Reference Section
REF OUT2 is sensed internally, and if more than 0.5 mA is
drawn externally from this reference, the chip goes into a power
on reset state. In this state the sigma-delta DAC is disabled, the
internal oscillator is stopped and the input data latch is cleared.
If there are 16 rising clock edges between successive LATCH
pulses, then the data being loaded to the input shift register is
assumed to be normal 4 mA to 20 mA data. On the rising edge
of the LATCH signal, the input shift register data is transferred
to the DAC latch in a 16-bit parallel transfer. In this case, the
16 bits of data in the DAC latch program the output current
between 4 mA for all 0s and 20 mA for all 1s (see Table II).
Data transferred to the AD421 should be MSB first.
REF OUT1 has limited current sinking capability. If REF
OUT1 is required to sink current, a resistive load of 100 kΩ
to COM should be added in addition to the 4.7 µF capacitor.
USING THE AD421
The AD421 can be programmed for normal 4 mA to 20 mA
operation or for alarm current operation. For normal operation,
the coding is 16-bit straight (natural) binary over an output
current range of 4 mA to 20 mA. For alarm current operation,
the coding is also straight binary but with 17 bits of resolution
over twice the span, 0 mA to 32 mA, although the part should
not be programmed outside the range of 3.5 mA to 24 mA. To
determine whether data written to the part is normal 4 mA to
20 mA data or alarm current data, the number of clock pulses
between two successive LATCH pulses are counted. If the num-
ber of pulses is 0–16 (modulo 32), it chooses normal mode; if it
is 17–31 (modulo 32), it chooses alarm current range.
If there are more than 16 clock pulses between successive
LATCH pulses, then the data being loaded to the input shift
register is assumed to be alarm current data. In this case, the
AD421 accepts 17 bits of data into its shift register. For situa-
tions where there are more than 17 clocks in the serial write
operation (for example, 24 clocks in a 3 × 8-bit transfer from the
serial port of a microcontroller) the AD421 simply accepts the
last 17 bits of the serial write operation. Data transferred in this
serial write operation is LSB last (i.e., the MSB is loaded on the
17th rising clock edge prior to the LATCH pulse). On the rising
edge of the LATCH signal, the input shift register data is trans-
ferred to the DAC latch in a 17-bit parallel transfer. In this
case, the 17 bits of data in the DAC latch program the output
current between 0 mA for all 0s and 32 mA for all 1s (see Table
III). However, in practice the AD421 cannot reliably produce a
current less than 3.5 mA or more than 24 mA.
4 mA to 20 mA Coding
Table II shows the ideal input-code-to-output-current relation-
ship for normal operation of the AD421. The output current
values shown assume a REF IN voltage of +2.5 V. With a
REF IN of +2.5 V, 1 LSB = 16 mA/65,536 = 244 nA. Figure 6
shows a timing diagram for programming the AD421 for normal
4 mA to 20 mA operation, the AD421 outputting a current
–7–
REV. C
AD421
of 11.147 mA. With 16 clock pulses between consecutive latch
signals data written is for normal 4 mA to 20 mA operation.
CLOCK
DATA
WORD "N"
0 0 1 1
Table II. Ideal Input/Output Code Table
for 4 mA to 20 mA Operation
0
1
1
0
0
0 0 0 0 0 0 0 0
X X X X X X X
Code
Output Current
0000 0000 0000 0000
0000 0000 0000 0001
0000 0000 0000 0010
4 mA
4.000244 mA
4.000488 mA
LATCH
Figure 7. Write Cycle for Programming Alarm Current
Data
0100 0000 0000 0000
1000 0000 0000 0000
1100 0000 0000 0000
8 mA
12 mA
16 mA
MICROPROCESSOR INTERFACING
AD421 – MC68HC11 (SPI BUS) INTERFACE
Figure 8 shows a typical interface between the AD421 and the
Motorola MC68HC11 SPI (Serial Peripheral Interface) bus.
The SCK, MOSI and SS pins of the 68HC11 are respectively
connected to the CLOCK, DATA IN and LATCH pins of the
AD421.
1111 1111 1111 1101
1111 1111 1111 1110
1111 1111 1111 1111
19.999268 mA
19.999512 mA
19.999756 mA
CLOCK
DATA
WORD "N +1"
WORD "N"
CLOCK
SCK
AD421*
68HC11
1
0
1
1
0
0
1
0
0
1
1
1
0
0
1
1
1
0 0 1
MOSI
DATA IN
LATCH
SS
* ADDITIONAL PINS OMITTED FOR CLARITY
LATCH
Figure 8. AD421 to 68HC11 Interface
A typical routine such as the one shown below begins by initializ-
ing the state of the various SPI data and control registers.
Figure 6. Write Cycle for 4 mA to 20 mA Operation
Alarm Current Coding
INIT
LDAA #$2F
;SS = 1; SCK = 0; MOSI = 1
Table III shows the ideal input-code-to-output-current relation-
ship for alarm current programming of the AD421. In this case,
the equivalent span is 0 mA to 32 mA but a reliable operating
span is 3.5 mA to 24 mA. The part may give an indeterminate
output for code values outside the range given in the table. As a
result, the user is advised to restrict the code programmed to the
part in alarm current mode to within the range shown in Table
III. Figure 7 shows a timing diagram for loading an alarm cur-
rent of 3.75 mA to the AD421 with an 8-bit microcontroller
using three 8-bit writes.
STAA PORTD ;SEND TO SPI OUTPUTS
LDAA #$38
STAA DDRD
LDAA #$50
STAA SPCR
;SS, SCK, MOSI = OUTPUTS
;SEND DATA DIRECTION INFO
;DABL INTRPTS, SPI IS MASTER & ON
;CPOL = 0, CPHA = 0, 1MHZ BAUDRATE
;LOAD ACCUM W/UPPER 8 BITS
NEXTPT LDAA MSBY
BSR
JMP
SENDAT ;JUMP TO DAC OUTPUT ROUTINE
NEXTPT ;INFINITE LOOP
SENDAT LDY
#$1000
;POINT AT ON-CHIP REGISTERS
BCLR $08,Y,$20 ;DRIVE SS (LATCH) LOW
STAA SPDR
LDAA SPSR
;SEND MS-BYTE TO SPI DATA REG
;CHECK STATUS OF SPIE
The output current values shown assume a REF IN voltage of
+2.5 V. With a REF IN of +2.5 V, an ideal 1 LSB = 32 mA/
131,072 = 244 nA.
WAIT1
WAIT2
BPL
WAIT1
;POLL FOR END OF X-MISSION
;GET LOW 8 BITS FROM MEMORY
;SEND LS-BYTE TO SPI DATA REG
;CHECK STATUS OF SPIE
LDAA LSBY
STAA SPDR
LDAA SPSR
Table III. Ideal Input/Output Code Table
for Alarm Current Operation
BPL
WAIT2; ;POLL FOR END OF X-MISSION
BSET $08,Y,$20 ;DRIVE SS HIGH TO LATCH DATA
RTS
Code
Output Current
3.5 mA
3.75 mA
4 mA
The SPI data port is configured to process data in 8-bit bytes.
The most significant data byte (MSBY) is retrieved from
memory and processed by the SENDAT routine. The SS pin is
driven low by indexing into the PORTD data register and clear
Bit 5. The MSBY is then sent to the SPI data register where it is
automatically transferred to the AD421 internal shift resistor.
0 0011 1000 0000 0000
0 0011 1100 0000 0000
0 0100 0000 0000 0000
0 1000 0000 0000 0000
1 0000 0000 0000 0000
1 0100 0000 0000 0000
1 0110 0000 0000 0000
1 1000 0000 0000 0000
8 mA
16 mA
20 mA
22 mA
24 mA
–8–
REV. C
AD421
The HC11 generates the requisite eight clock pulses with data
valid on the rising edges. After the MSBY is transmitted, the
least significant byte (LSBY) is loaded from memory and
transmitted in a similar fashion. To complete the transfer, the
LATCH pin is driven high when loading the complete 16-bit
word into the AD421.
V
CC
2.2F
0.1F
V
V
V
CC
10k⍀
V
CC
CLOCK
LATCH
CLOCK
AD421 TO MICROWIRE INTERFACE
CC
AD421*
The flexible serial interface of the AD421 is also compatible
with the National Semiconductor MICROWIRE interface. The
MICROWIRE interface is used in microcontrollers such as the
COP400 and COP800 series of processors. A generic interface
to use the MICROWIRE interface is shown in Figure 9. The
G1, SK, and SO pins of the MICROWIRE interface respec-
tively connect to the LATCH, CLOCK, and DATA IN pins of
the AD421.
10k⍀
LATCH
CC
10k⍀
DATA IN
DATA IN
COM
* ADDITIONAL PINS OMITTED FOR CLARITY
CLOCK
SK
SO
G1
AD421*
MICROWIRE
Figure 10. Opto-Isolated Interface
DATA IN
LATCH
APPLICATIONS SECTION
Basic Operating Configuration
Figure 11 shows the basic connection diagram for the AD421
operating at 5 V. This circuit shows the minimum of external
components to operate the AD421. In the diagram, the AD421’s
regulator loop in conjunction with the DN25D pass transistor
provides the VCC voltage for the AD421 itself and for other
devices in the transmitter. The VCC pin should be well decou-
pled with a 2.2 µF capacitor to ensure regulator stability and to
absorb power glitches on the VCC line of the AD421 and other
devices in the system. If the AD421 is operated with VCC = 3 V,
the transfer function shifts negative. To correct for this a 16 kΩ
resistor connected between COM and LOOPRTN will approxi-
mately compensate for the VCC supply sensitivity in moving from
5 V to 3 V by adjusting the gain of the AD421.
* ADDITIONAL PINS OMITTED FOR CLARITY
Figure 9. AD421 to MICROWIRE Interface
Opto-Isolated Interface
The AD421 has a versatile serial 3-wire serial interface making
it ideal for minimizing the number of control lines required for
isolation of the digital system from the control loop. In intrinsi-
cally safe applications or due to noise, safety requirements, or
distance, it may be necessary to isolate the AD421 from the
controller. This can easily be achieved by using opto-isolators.
Figure 10 shows an opto-isolated interface to the AD421 where
CLOCK, DATAIN and LATCH are driven from opto-couplers.
Be aware of signal inversion across the opto-couplers. If opto-
couplers with relatively slow rise and fall times are used, Schmitt
triggers may be required on the digital inputs to prevent errone-
ous data being presented to the DAC.
V
TO EXTERNAL
CIRCUITRY
CC
DN25D
2.2F
4.7F
COM
COM
LV
REF OUT2
REF OUT1
REF IN
V
CC
DRIVE
V
LOOP
0.01F
COMP
DATA
CLOCK
1k⍀
AD421
1000pF
BOOST
LATCH
LOOP RTN
COM
C1
C2
C3
0.0033F
COM TO EXTERNAL
CIRCUITRY
0.01F 0.01F
Figure 11. Basic Connection Diagram
–9–
REV. C
AD421
A capacitor of 0.01 µF connected between COMP and DRIVE
is required to stabilize the feedback loop formed with the
regulator op amp and the external pass transistor. An external
snubber circuit of 1 kΩ and 1000 pF is required between the
DRIVE pin and COM and a 0.1 µF cap between COMP and
DRIVE to stabilize the feedback loop formed by the regulator
op amp and the external pass transistor.
Smart Transmitter
The AD421 is intended for use in 4 mA to 20 mA smart trans-
mitters. A smart transmitter is a system that incorporates a
microprocessor system which is used for linearization and
communication. Figure 13 shows a block diagram of a typical
smart transmitter. In this example, the transmitter does not have
any digital communication capabilities.
The internal 2.5 V reference on the AD421 is used as the refer-
ence for the AD421 and this has to be decoupled with a 4.7 µF
capacitor for compensation and stability purposes. The sigma-
delta DAC on the part consists of a second order modulator
followed by a continuous time filter. The resistors for each of
the filter sections are on-chip while the capacitors are external
on the C1 to C3 pins. To meet the specified full-scale settling
on the part, low dielectric absorption capacitors (NPO) are
required. Suitable values for these capacitors are C1 = C2 =
0.01 µF, and C3 = 0.0033 µF.
MEMORY
4mA TO 20mA
A/D
CONVERTER
MICRO-
PROCESSOR
D/A
CONVERTER
SENSORS
MEASUREMENT
CIRCUIT
Figure 13. Typical Smart Transmitter
Figure 14 shows a typical smart transmitter application circuit
using the AD421.
The digital interface on the AD421 consists of just three wires:
DATA, CLOCK and LATCH. The interface connects directly
to the serial ports of commonly-used microcontrollers without
the need for any external glue logic. Data is loaded into an input
shift register on the rising edge of the CLOCK signal and is
transferred to the DAC latch on the rising edge of the LATCH
signal.
The sensor voltage to be measured at the transmitter is con-
verted using a high resolution sigma-delta converter such as
the AD7714 or AD7715. These devices have an on-board PGA
which can provide gains on the analog front end from 1 to 128.
This allows for an analog input range as low as 10 mV which
allows the transducer to be connected directly to the ADC. The
AD7714/AD7715 have digital calibration techniques which are
used to eliminate gain and offset errors. In addition, back-
ground calibration techniques are provided whereby the part
continually calibrates itself and the user does not have to
worry about issuing periodic calibration commands to remove
effects of time and temperature drift.
Reduce Power Load on External FET
Figure 12 shows a circuit where an external NPN transistor is
added to reduce the power loading on the FET. The FET will
supply the VCC and an external high voltage NPN bipolar tran-
sistor can carry the BOOST current. The BOOST pin sinks the
necessary current from the loop so that the current flowing into
BOOST plus the current flowing into COM is equal to the
programmed loop current. The external NPN transistor reduces
the external power load that the FET has to carry to less than
750 µA if no other components share the VCC line and to less
than 4 mA in applications that share the same VCC line as the
AD421.
In normal operation the microprocessor reads the data from the
AD7714/AD7715. After the data is processed by the micro-
controller, the data is transferred from the serial port of the
processor to the AD421 for transmission over the 4 to 20 mA
loop back to the control center.
The AD421 regulates the loop voltage to create power for the
rest of the transmitter circuitry. In Figure 14, the derived VCC
voltage is 3.3 V which is achieved by connecting the LV pin to
VCC through 0.01 µF. REF OUT2 provides the reference volt-
age for the AD421 itself while REF OUT1 provides the refer-
ence voltage for the AD7714/AD7715.
LOOP(+)
V
TO EXTERNAL
CIRCUITRY
CC
DN25D
BC639/BC337
2.2F
COM
LV
V
CC
75k⍀
112.5k⍀
AD421
134k⍀
DRIVE
1.21V
BANDGAP
REFERENCE
0.01F
COMP
1k⍀
1000pF
121k⍀
BOOST
80k⍀
40⍀
LOOP RTN
LOOP(–)
Figure 12. External NPN Transistor Reduces Power Load
on FET
–10–
REV. C
AD421
DN25D
3.3V
0.01F
2.2F
0.1F
DV
DD
AV
DD
BOOST
V
LV
CC
SENSORS
RTD
mV ⍀ TC
1.25V
REF OUT1
REF IN
LOOP
REF OUT2
REF IN
4.7F
100k⍀
4.7F
ANALOG
TO
DIGITAL
CONVERTER
POWER
0.01F
V
CC
AMBIENT
TEMP
SENSOR
COMP
DRIVE
CLOCK
LATCH
DATA
AD7714/
AD7715
MICROCONTROLLER
GND
1k⍀
1000pF
MCLK IN
AD421
MCLK OUT
CS
LOOP
RTN
DATA OUT
SCLK
COM
DATA IN
C1
C2
C3
AGND
DGND
Figure 14. AD421 in Smart Transmitter Application
HART Interfacing
Figure 16 shows a block diagram of a smart and intelligent
transmitter. An intelligent transmitter is a transmitter in which
the functions of the microprocessor are shared between deriving
the primary measurement signal, storing information regarding
the transmitter itself, its application data and its location and
also managing a communication system which enables two way
communication to be superimposed on the same circuit that
carries the measurement signal. A smart transmitter incorporat-
ing the HART protocol is an example of a smart intelligent
transmitter.
The HART protocol uses a frequency shift (FSK) keying tech-
nique based on the Bell 202 Communication Standard which is
one of several standards used to transmit digital signals over
the telephone lines. This technique is used to superimpose
digital communication on to the 4 mA to 20 mA current loop
connecting the central system to the transmitter in the field.
Two different frequencies, 1200 Hz and 2200 Hz, are used to
represent binary 1 and 0 respectively, as shown in Figure 15.
These sine wave tones are superimposed on the dc signal at a
low level with the average value of the sine wave signal being
zero. This allows simultaneous analog and digital communica-
tions. Additionally, no dc component is added to the existing
4 mA to 20 mA signal regardless of the digital data being sent
over the line. Consequently, existing analog instruments con-
tinue to work in systems that implement HART as the low-pass
filtering usually present effectively removes the digital signal. A
single pole 10 Hz low-pass filter effectively reduces the commu-
nication signal to a ripple of about 0.01% of the full-scale
signal. The HART protocol specifies that master devices like a
host control system or a hand held terminal transmit a voltage
signal whereas a slave or field device transmits a current signal.
The current signal is converted into a corresponding voltage by
the loop load resistor.
MEMORY
4mA TO 20mA
A/D
CONVERTER
MICRO-
PROCESSOR
D/A
CONVERTER
SENSORS
MEASUREMENT
CIRCUIT
COMMUNICATION
SYSTEM
Figure 16. Smart and Intelligent Transmitter
Figure 17 shows an example of the AD421 in a HART transmit-
ter application. Most of the circuit is as outlined in the smart
transmitter as shown in Figure 14. The HART data transmitted
on the loop is received by the transmitter using a bandpass filter
and modem and the HART data is transferred to the micro-
controller’s UART or asynchronous serial port. HART data to
be transmitted on the loop is sent from the microcontroller’s
UART or asynchronous serial port to the modem. It is then
waveshaped before being coupled onto the AD421’s output at
the C3 pin. The value of the coupling capacitor CC is determined
by the waveshaper output and the C3 capacitor of the AD421. The
blocks containing the Bell 202 Modem, waveshaper and bandpass
filter come in a complete solution with the 20C15 from Symbios
Logic, Inc., or HT2012 from SMAR Research Corp.
APPROX
+0.5mA
APPROX
–0.5mA
2200Hz
“0”
1200Hz
“1”
For a more complete AD421-20C15 interface, please refer to
Application Note AN-534 on the Analog Devices’ website
www.analog.com or contact your local sales office.
Figure 15. HART Transmission of Digital Signals
–11–
REV. C
AD421
DN25D
3.3V
0.01F
2.2F
0.1F
DV
DD
AV
DD
BOOST
LV
V
CC
SENSORS
RTD
mV ⍀ TC
1.25V
REF IN
REF OUT1
REF OUT2
REF IN
LOOP
POWER
100k⍀
4.7F
4.7F
ANALOG
TO
DIGITAL
CONVERTER
0.01F
V
CC
COMP
DRIVE
AMBIENT
TEMP
SENSOR
CLOCK
LATCH
DATA
AD7714/
AD7715
MICROCONTROLLER
GND
1k⍀
MCLK IN
1000pF
AD421
MCLK OUT
CS
LOOP
RTN
DATA OUT
SCLK
COM
DATA IN
C1
C2
C3
AGND
DGND
C
*
C
WAVEFORM
SHAPER
BANDPASS
FILTER
HART
MODEM
BELL 202
HT20C12/20C15
*FOR SELECTION OF C , REFER TO AN-534
C
Figure 17. AD421 in HART Transmitter Application
Current Source
across R2. The ratio of R1 to R2 determines the current that
flows in the load resistor RL. IL = [1 + R1/R2] × IPROG, where IL
is the current that flows in the load resistor RL and IPROG is the
current programmed to the AD421. R1 and R2 are external to
the AD421 and will need to be matched resistors to obtain a
highly accurate current source.
Figure 18 shows an application circuit for the AD421 being
used as a current source. The current programmed to the
AD421 (4 mA to 20 mA) will develop a voltage across R1.
This same voltage due to negative feedback will be generated
5 VOLT
REGULATOR
+5V
V
OUT
IN
S
2.2F
10k⍀
4.7F
COM
10k⍀
COM
COM
V
REF IN
DATA
LV
REF OUT2
REF OUT1
CC
10k⍀
DRIVE
COMP
DATA
BOOST
AD421
CLOCK
CLOCK
LATCH
LOOP
RTN
LATCH
C3
C1
C2
COM
R1
R2
0.01F
0.01F
0.0033F
R
L
V
RETURN
S
Figure 18. AD421 in Programmable Current Source/Sink
–12–
REV. C
AD421
Battery Backup
Figure 19 shows an application circuit for the AD421 where the
micro and memory sections of the circuitry are protected against
losing data if the loop is broken. The backup circuit switches
from VCC to battery voltage without a glitch when VCC power is
lost. The IRFF9113 acts as a current source during normal
operation and provides a constant charging current to the supercap
or Nicad. The loss of VCC drops the IRFF9113’s gate voltage to
zero volts, which allows the battery or supercaps current to flow
through the MOSFETs channel and integral body diode to
provide power for the micro and memory sections. To calibrate
this circuit, connect an ammeter in series with the battery or
supercap. Then with VCC and the load present adjust the 100 kΩ
potentiometer for the battery charging current recommended by
the battery or supercap manufacturer.
DN25D
IN3611
IRFF9113
0.1F
4.7F
IN3611
V
LOOP
V
CC
100k⍀
2.2F
MICRO/
MEMORY
V
CC
SUPERCAP
GND
DRIVE
AD421*
LOOP
RTN
COM
*ADDITIONAL CIRCUITRY OMITTED FOR CLARITY
Figure 19. Battery Backup Circuit
Nonrechargeable batteries should not be used in this application
due to danger of explosion.
–13–
REV. C
AD421
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
16-Lead Plastic DIP
(N-16)
0.840 (21.34)
0.745 (18.92)
16
1
9
0.280 (7.11)
0.240 (6.10)
8
0.325 (8.26)
0.195 (4.95)
0.115 (2.93)
0.300 (7.62)
PIN 1
0.060 (1.52)
0.015 (0.38)
0.210 (5.33)
MAX
0.130
(3.30)
MIN
0.160 (4.06)
0.115 (2.93)
0.015 (0.381)
0.008 (0.204)
0.070 (1.77) SEATING
0.045 (1.15)
0.100
(2.54)
BSC
0.022 (0.558)
0.014 (0.356)
PLANE
16-Lead (Wide Body) Small Outline Package
(R-16)
0.4133 (10.50)
0.3977 (10.00)
16
9
1
8
0.1043 (2.65)
0.0926 (2.35)
PIN 1
0.0291 (0.74)
0.0098 (0.25)
x 45؇
0.0118 (0.30)
0.0040 (0.10)
0.0500 (1.27)
0.0157 (0.40)
8؇
0؇
0.0500
(1.27)
BSC
0.0192 (0.49)
0.0138 (0.35)
SEATING
PLANE
0.0125 (0.32)
0.0091 (0.23)
–14–